1. aligning the module with the slot guides Wi Ensure that the module is firmly seated in the slot 6 Use the screws from step 3 to secure the module to the workstation or file server housing techsupport transition com Click the Transition Now link for a live Web Chat 3 N GxX xx 01 x Gigabit Ethernet NIC Cable Specifications Technical Specifications For models N GxX xx 01 and N GxX xx 01 L Fiber cable Standards IEEE 802 3 802 1P 802 1Q Bit error rate lt 10 9 Expansion bus standard PCI 2 2 64 32 bit 33 66Mhz standard Single mode fiber recommended 9 um Daarate 1000Mbps fiber media Multimode fiber recommended 62 5 125 um P Multimode fiber optional 100 140 85 140 50 125 um LED LINK ACT on the bracket N GSX SC 01 x 850 nm multimode ON communication link Fiber optic transmitter power min 9 5 dBm max 4 0 dBm e FLASHING activity on link l Fiber optic receiver sensitivity min 18 0 dBm max 0 0 dBm FDX on the bracket ON full duplex link Link budget 8 5 dB N GSX LC 01 x 850 nm multimode Drivers e NetWare Server 4 x 5 x 6 x i A e Netware DOS Client ODI Fiber optic transmitter power min 9 5 dBm max 4 0 dBm 4 wae i e Windows 98 2000 2003 NT4 0 XP Fiber optic receiver sensitivity min 18 0 dBm max 0 0 dBm Link budget 8 5 dB eea E e SCO UnixWare 7 1x N GLX SC 01 x 1310 nm single mode e OpenUnix 8 0 Fiber optic transmitt
2. EN55024 CE Mark FCC regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European regulations Caution This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betr
3. 1 800 260 1312 International 00 1 952 941 7600 24 hours Installation and Configuration continued PCI bus system and configuration e Ensure that the PCI machine supports master slots and INT multiple sharing and timing functionality e DO NOT install N GxX xx 01 x NICs in PCI slave slots Please refer to your PC system manual and select the appropriate configuration settings e When installing multiple N GxX xx 01 x NICs at the server station you should correctly configure the IRQ settings of the PCI slot e N GxX xx 01 x NIC server modules share the same INT line with the driver supporting multiple INT services The IRQ of each N GxX xx 01 x NIC should not conflict with other boards e Gigabit Ethernet Fiber Partner should be set at full duplex mode with NWay flow control Ensure that all network nodes are configured at an identical operation mode Improper operation and flow control mode between fiber nodes will render the LAN to work poorly The operating mode should match at both ends working status Installation To install the N GxX xx 01 x module do the following Important Install the N GxX xx 01 x NIC in a master slot only 1 Locate a master slot on the PC workstation or file server 2 Remove the cover from the PC workstation or file server keep all screws 3 Remove and keep the screws holding the cover over the installation slot 4 Carefully slide the N GxX xx 01 x NIC into the master slot
4. TRANSITION networks USER S GUIDE N GxX xx 01 standard N GxX xx 01 L low profile The N GxX xx 01 x gigabit ethernet Network Interface Card NIC provides a 1000Base SX LX fiber port to deliver fiber optic connectivity to the desktop in fiber rich LAN environments With both standard and low profile form factors driver support for most popular operating systems and supports 32 64 bit PCI 2 2 plug and play capability all help make installation a breeze in virtually any PC on the Network Part Number Port One Duplex Fiber Optic 1000Base SX LX N GSX SC 01 SC 850 nm multimode 62 5 125um 220 m 722 ft N GSX SC 01 L 50 125um 550 m 1804 ft N GSX SC 01 020 SC 850 nm multimode 62 5 125um 220 m 722 ft N GSX SC 01 L 020 50 125um 550 m 1804 ft N GSX LC 01 LC 850 nm multimode 62 5 125um 220 m 722 ft N GSX LC 01 L 50 125um 550 m 1804 ft N GSX LC 01 020 LC 850 nm multimode 62 5 125um 220 m 722 ft N GSX LC 01 L 020 50 125um 550 m 1804 ft N GLX SC 01 SC 1310 nm single mode 10 km 6 2 miles N GLX SC 01 L N GLX LC 01 SC 1310 nm single mode 10 km 6 2 miles N GLX LC 01 L Optional accessories sold separately Part Number Description BTR NGX PXE PXE Bootable ROM Chip Typical maximum cable distance Actual distance is dependent upon the physical characteristics of the network installation The 020 designation at t
5. er power min 9 5 dBm max 3 0 dBm Fiber optic receiver sensitivity min 20 0 dBm max 3 0 dBm Boot server support PXE Boot ROM Link budget 10 5 dB N GLX LC 01 x 1310 nm single mode PCB dimensions 2 2 x 6 5 x 09 Fiber optic transmitter power min 9 5 dBm max 3 0 dBm 56 mm x 165 mm x 23 mm Fiber optic receiver sensitivity min 20 0dBm max 3 0 dBm Link budget The fiber optic transmitters on the device meet Class I Laser safety requirements 10 5 dB per IEC 825 CDRH standard and comply with 21CRF1040 10 and 21CRF1040 11 Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Shipping weight Power consumption MTBF Opearting temp Storage temp 1 Ib 0 45 kg 2 0A 5VDC 127 234 hours Bellcore7 V5 0 0 C to 50 C 32 F to 122 F 25 C to 85 C 13 C to 185 F Humidity 5 to 95 non condensing Altitude 0 to 10 000 feet Warranty Lifetime WARNING Visible and invisible laser radiation when open DO NOT stare into the beam or view directly with optical instruments Failure to observe this warning could result in damage to your vision or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure The information in this manual is subject to change without further notice Go to www transition com TransitionNetworks Products2 Static MediaConversion aspx to check fo
6. he end of the part number means sold in packs of 20 NICs only There are no changes to NIC specifications Installation and Configuration 2 Cable Specifications 4 Technical Specifications 5 Troubleshooting 6 Contact US puos eecnenesa eas 7 N GxX xx 01 x Gigabit Ethernet NIC Installation and Configuration Checklist Before installing the N GxX xx 01 x NIC verify that the package contains the following items e N GxX xx 01 x NIC LAN driver CD Please notify your sales representative if any item is missing or damaged Description The N GxX xx 01 x NIC has a bootable ROM socket bootable ROM chip sold separately The two LED indicators LINK ACT and FDX located on the bracket show network board link activities collision and full duplex statuses See Figure 1 PXE ROM Socket sS 7 la yo Link ACT LED to il FDX LED Q6 A i wl i w RX Figure 1 LEDs and PXE ROM Socket N GxX xx 01 x NIC configuration CAUTION Wear a grounding strap and observe electrostatic discharge precautions when installing the N GxX xx 01 x NIC Failure to observe this caution could result in damage or failure of the N GxX xx 01 x NIC For motherboards with automatic PCI configuration e No specific setup is needed e You can enter the system BIOS setup menu to view or specify the interrupt INT line of the PCI slots Tech Support
7. he equipment specified above conforms to the above Directive s and Lp Aaa ANSTTION Declaration of Conformity Minneapolis MN 55344 U S A del N GxX xx 01 and N GxX xx 01 L Network Interface Cards N GLX LC 01 x EMC Directive 89 336 EEC this declaration refers is in conformity with the following standards Standard s September 9 2005 Stephen Anderson Vice President of Engineering Date Tech Support 1 800 260 1312 International 00 1 952 941 7600 24 hours Contact Us Technical support Technical support is available at techsupport transition com US and Canada 1 800 260 1312 24 hours e International 00 1 952 941 7600 24 hours Transition now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web based seminar Transition networks provides seminars via live web based training Log onto www transition com and click the Learning Center link Email Ask a question anytime by sending an email to our technical support staff techsupport transition com Address Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Telephone 952 941 7600 Toll free 800 526 9267 Fax 952 941 2322 techsupport transition com Click the Transition Now link for live Web chat N GxX xx 01 x Gigabit Ethernet NIC Compliance Information CISPR22 EN55022 Class A CE Mark CISPR22 EN55022 Class A
8. ieb dieses Ger tes Rundfunkst rungen auftreten In diesem Fall ist der Benutzer fiir Gegenmafinahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques approprices CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein 6ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformitat Trademark notice All registered trademarks and trademarks are the property of their respective owners Copyright restrictions 2004 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks 8 Printed in the U S A Manual Part Number and Rev A 33347 A
9. r updates to this manual by checking the revision level techsupport transition com Click the Transition Now link for live Web chat 5 N GxX xx 01 x Gigabit Ethernet NIC Troubleshooting D iagnostics LEDs and Boot ROM LEDS e The Link ACT LED green turns ON when cable connection is good and speed is at 1000Mpbs e The FDX LED green truns ON when full duplex mode is active Boot ROM To add the remote boot feature to a workstation insert the Boot ROM into the ROM socket See Figure on page 2 After power UP the LINK ACT LED should light if not check the following 1 Confirm that the N GxX xx 01 x NIC is properly inserted into the master slot 2 Confirm that the PC is properly connected to a power source and with the power source turned ON 3 Check the fiber cable for proper connection 4 Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 if those steps fail to produce the desired result Note To connect this device to a router bridge or switch please refer to the corresponding technical manual for the device R Cis networks Name of Mfg Transition Networks 6475 City West Parkway Mo Part Number N GSX SC 01 x N GSX LC 01 x N GLX SC 01 x Regulation Purpose To declare that theN GxX xx 01 and N GxX xx 01 L to which CISPR 22 1997 A1 2000 EN 55022 1998 A 1 2000 Class A FCC Part 15 Subpart B 21CFR subpart J I the undersigned hereby declare that t