Home

Transition Networks E-TBT-HB

image

Contents

1. 0 5 LAN Master T8 Powering the LANMaster T8 To power ON the LAN Master T8 1 AtLANMaster T8 back locate the power receptacle and associated fuse NOTE Fuse must be installed at correct setting for power source voltage before connecting to AC outlet 2 Verify that fuse is installed at correct setting for power source voltage NOTE The installed fuse rating is indicated by the reading at lower right comer of fuse holder If not installed at correct setting for power source voltage 110 120 Orientation 220 240 Orientation 4 002 022 A 021 011 110 120 220 240 Fuse Holder Fuse Holder e Carefully open fuse receptacle using a small flat blade screwdriver e Rotate fuse holder 180 to the correct rating orientation e Install fuse holder in correct rating orientation e Close fuse receptacle 3 Plug unit end female of power cord into LAN Master T8 power receptacle 4 Plug outlet end male of power cord into correct voltage AC wall socket 5 AtLANMaster T8 front verify that POWER LED is illuminated 3 Port Ethemet Hub w SIC Sot 14 BNC Connector 1OBase2 Connection The thinnet coaxial card E CX SIC 50 ohm terminator provides a BNC connector to 10Base2 N NOTE Verify that coax cables on LAN Master T8 are terminated properly at both ends
2. The bridge card E BR SIC also provides a female AUI connector for connection through an AUI drop cable to the 10Base5 port ona transceiver NOTE The bridge card enables site configurable filtering of packets to and from the network backbone Male AUI Connector PC Connection The male AUI card EAU I DC SIC provides a male AUI connector for connection through an AUI drop cable to a 10Base5 port ona powered PC 8 Port Ethernet Hub w IC Slot 12 Connecting Cable to Side In Cards Connections between installed LAN Master T8 SICs or between a LAN Master T8 SIC and a hub or terminal device include e Twisted Pair Connector 10BaseT e Female AUI Connector 10Base5 e Male AUI Connector PC e BNC Connector 10Base2 e Fiber Optic Connector Fiber O ptc Twisted Pair Connector 10BaseT Connection The twisted pair card E TBT SIC provides an RJ 45 connector to 10BaseT OR straight through H EEREREe F Bee I To connect 10BaseT Cable to Pocket Hub SIC RJ 45 connectors 1 Locate or build 10BaseT cables with the following characteristics 802 3 compliant See page 18 e correct straight through or crossover cable configuration for site installation See page 7 e male RJ 45 plug connectors installed at both ends of cable 2 Connect male RJ 45 plug connector at one end of 10BaseT cable to LAN Master T8 RJ 45 jack connecto
3. For assistance in installing using or maintaining the TRANSITION Networks LAN Master T8 LOBaseT Ethernet Hub contact TRANSITION Networks Technical Support at 800 260 1312 or contact your local distributor LANMaster TS 8 Port Bthemet Hub w IC Got E TBT HB 0802 7364 A Compliance Information UL Listed FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own cost Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the Radio Interference Regulations of the Canadian Department of Communications Copyright Restrictions 1995 TRANSITION Networks Inc All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks I
4. Fiber O ptic 2000 meters 10Base5 500 meters 10Base2 185 meters 10BaseT 100 meters And e Since the LAN Master T8 8 Port Ethernet Hub w SIC Slot functions as an Ethernet repeater the entire LAN Master T8 8 Port Ethernet Hub w SIC Slot installation should comply with the IEEE Ethernet 802 3 specification e RJ 45 connected cables should be configured as crossover or straight through according to installation requirements 8 Port Ethernet Hub w IC Sot Ensuring Compliance with 5 Segment Rule To conform to the Ethernet 802 3 specification when connecting LAN Master T8 Hubs the transmission path between any two Data Terminating Equipment DTE devices can consist of no more than five segments NOTE A segment is the cable connection between cable interfaces in an Ethernet LAN To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the terminals segment 1 and the segment connected to the other terminal segment n n total number of segments and must be 5 or fewer 3 To verify that no segment paths contain more than n segments assign segment paths and numbers to all other terminals a SIC Connection a
5. In a coax thinnet installation the first and last device in a daisy chain must be terminated with a 50 ohm terminator Additionally the 10Base2 segment must be grounded to earth ground va Z 50 ohm terminator Fiber Optic Connector 10BaseFL Connection The fiber optic card E FRL SIC provides one set of transmit TX and receive RX connectors to fiber optic cable The redundant fiber optic card E FL RED SIC provides a back up fiber optic connection by providing two sets of transmit TX and receive RX connectors to fiber optic cable up to 2000 meters a a 13 LAN Master T8 Ensuring Correct 1OBaseT Configuration The 10BaseT cable and RJ 45 connectors for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 connectors for Hub to Hub connections must be configured as crossover NOTE When installing the LANMaster T8 Hub using the MDI port a crossover cable is not needed The MDI switch can be used to change the straight through configuration to crossover at port 8 The two active pairs 12345678 in a 10BaseT network RJ 45 Pin Assignments A are pins 1 amp 2 and pins 3 amp 6 Use only dedicated wire pairs such as blue white amp l a Re Plus white bl ue aes orange white amp Ma ae white orange for the val active pins Straight Through Cable at RJ 45 Plug Hub 2 222 eee PC transce
6. 7 Installing LAN Master T8 on Flat Surface 8 Connecting 10BaseT Cable at LAN Master T8 Front 9 Installing Slide In Cards 0000002 e ee eee 10 Connecting Cable to Slide In Cards 20005 11 Twisted Pair Connector lOBaseT Connection 11 Female AUI Connector LOBase5 Connection 12 Male AUI Connector PC Connection 2 0005 12 BNC Connector 10Base2 Connection 0055 13 Fiber O ptic Connector Fiber Optic Connection 13 Powering the LANMasterT8 2 0202000005 14 4 OPERATION 2 00002 eee 15 Monitoring Power LED 02000 eee eee 15 Monitoring Port Indicator LEDs 15 5 MAINTENANCE 20002 eee et LO LAN Master T8 SPECIFICATIONS 000 ccc eee eeeeee 17 CABLE SPECIFICATIONS 1 0c ee 17 POLICY AND PROCEDURE 00000 0 cease 19 8 Port Ethernet Hub w IC Sot L INTRODUCTION This guide is intended for the system or network administrator responsible for installing and monitoring a TRANSITION Networks LAN Master T8 8 Port Ethernet Hub w SIC Slot A working knowledge of local area network LAN operations including familiarity with communications protocols used on interconnected LANs is assumed The LAN Master T8 Hub w SIC Slot The LAN Master T8 8 Port Ethernet Hub w SIC Slot E TBT HB 0802 is a stand alone fully functional Ethernet repeater LAN M
7. BY CUSTOMER OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE OF THIS SALE The sole purpose of this remedy shall be to provide the customer with the replacement or repair of non conforming goods in the manner provided here in This exclusive remedy shall not be deemed to have failed of its essential purpose so long as TN is willing and able to repair or replace the non conforming goods or refund the purchase price therefore in the manner provided herein TN reserves the right to inspect products claimed to be defective under either at the customer s location or at TN s plant TN assumes no liability for labor charges incidental to the adjustment service repairing removal or replacement of the product or other costs or the expense of repairs made outside of its factory except when made pursuant to TN s prior written consent All retums must be received in the same condition as the original shipment 19 LAN Master T8 Table of Contents 1 INTRODUCTION 2 0 000 eee 7 The LAN Master T8 8 Port Ethernet Hub w SIC Slot 1 LAN Master T8 Features 0 2 0 000 cece eee 1 Networking the LANMasterT8 020000 e ee euee 2 Connectors Indicators and Switches 3 2 ATECONSIDERATIONS 0002 eee et 4 Ensuring Compliance with 5 Segment Rule 5 Ensuring Correct 10BaseT Configuration 6 3 INSTALLATION 0000 eee 2 Unpacking the LAN Master T8 2 200000000
8. T8 frame 4 Rotate the Side In Card thumbscrews into the LAN Master T8 threaded holes 8 Port Ethernet Hub w IC Slot 10
9. NT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENTATIONS REGARDING SUCH PRODUCTS MADE BY TN ITS EMPLOYEES AGENTS OR REPRESENTATIVES B Limitations and Exclusions If customer believes any goods sold hereunder are defective pursuant to the warranty and within the warranty period set forth above the customer must notify TN within such period TN will promptly issue a retum form for such goods Upon receipt of the form customer is to promptly retum the allegedly defective goods at customer s expense and shipped prepaid to your distributor or TN refer to the next subsection C Return Procedure No goods will be accepted for rebum unless a prior return form is obtained from TN freight charges have been prepaid by customer TN or the distributor shall at its option either i repair such goods free of charge if warranty within two years ii repair such goods at a minimum of 100 One Hundred dollars per item if warranty expired iii replace such goods free of charge or iv accept the retum of such goods and credit current price therefore to the customer THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY IN NO EVENT SHALL TN BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHETHER FOR BREACH OF ANY WARRANTY FOR BREACH OR REPUDIATION OF ANY OTHER TERM OR CONDITION OF SALE FOR NEGLIGENCE ON THE BASIS OF STRICT LIABILITY CONTRACT OR OTHERWISE AND IRRESPECTIVE OF WHETHER TN IS INFORMED
10. aracteristics tttt A network of four repeaters and five segments can have up to 3 coax segments and 2 required link segments The maximum length of a FOIRL link segment must not exceed 500 meters If your network has three repeaters and four segments the maximum length of a FOIRL link segment must not exceed 1000 meters 8 Port Ethernet Hub w IC Slot 18 LAN Master T8 Specifications Dimensions 9 25 X 7 75 X 1 75 235mm x 197mm x 45mm Environment Temperature 0 50 C Humidity 10 90 non condensing Altitude 0 10 000 feet Cable Specifications 1OBase2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802 3 10Base2 specifications e 50W RG 58 Ethernet approved cable AUI Cable Specifications The 15 pin AUI cable must be IEEE approved 10BaseFL Cable Specifications The IEEE 802 3 standard for fiber optic segments are e 62 5 125umM multimode fiber recommended 100 140 um multimode fiber 85 um multimode fiber e 50 125 um multimode fiber 17 LAN Master T8 Networking the LAN Master TS 8 Port Ethernet Hub w SIC Slot 10BaseT connections can be made to terminal equipment and to other LAN Master T8s Additionally optional Slide In cards SICs can be installed at the back of the LAN Master T8 to provide a connection to the network backbone SIC Connection LILI 10B
11. aseT 100 meters 10Base2 185 meters 10Base5 500 meters 10BaseFL 2000 meters LI LILI 8 Port Ethernet Hub w IC Sot Connectors Indicators and Switches CONNECTORS INDICATORS MDI SWITCH Connectors Eight 8 RJ 45 10BaseT connectors are located on the front of the LAN Master T8 Hub One 1 power connector is located on the back of the LAN Master T8 Hub NOTE Slide In cards SICs can provide optional additional fiber optic male and female AUI BNC and RJ 45 connectors LEDs The Power LED indicates the LAN Master T8 Hub connection to extemal power The Port Indicator Link Partition LEDs indicate for each port the status of the LAN Master T8 Hub connections to the 10 BaseT network MDI MDI X Switch The MDI MDI X switch allows the RJ 45 connection at Port 8 to be changed from straight through to crossover 3 LAN Master T8 5 MAINTENANCE WARNING DO NOT UNDER ANY CIRCUMSTANCES open and attempt to repair the LAN Master T8 8 Port Ethemet Hub w SIC Slot or power supply adapter unit Failure to observe this waming could result in personal injury or death from electrical shock NOTE Failure to observe the above warming will immediately void the warranty Technical Support Contact For assistance in fault isolation a
12. aster T8 8 Port Ethernet Hub w SIC Slot 2 3 4 E 5 6 7 8 Ea MLS N aee a Aawa ree Minneapolis MN 55344 USA MDI MDIX LAN Master TS 8 Port Ethernet Hub w SIC Slot Features e Media Dependent Interface MDI switch eliminates need for RJ 45 crossover cable connection between LAN Master T8 devices e Comes with internal power supply e Complies with Ethernet 802 3 e Slide In Card SIC slots for optional installation of additional media connections 1 LAN Master T8 10BaseT Cable Specifications The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802 3 10BaseT specifications Either shielded or unshielded twisted pair can be used Level 3 wire or better is recommended Gauge 2 000 2 ee 26 to 22 AWG e Attenuation Less than 11 5 dB 5 10 MHz e Differential Characteristic 85 110 Q Impedance 10 MHz e Maximum Distance 100 Meters 330 Feet Segment Distance Media Maximum Maximum Minimum Maximum Segment Number Segment Medium Medium Type MAU Length Propagation End to End Segment meters Velocityt Propagation Delay Segment 10Base5 100 500 0 77 c 2570 10Base2 30 185 0 65 c 950 AUI tt 1 DTEMAU 50 0 65 c 257 10BaseT 2 100 ttt 0 59 c 1000 FOIRL 2 1000 tttt 0 66 c 5000 FL 2 2000 0 66 c 5000 t c 3 x 108 meters second tt AUI connection is not a segment ttt Maximum segment length depends on the cable ch
13. iver NIC printer RJ 45 Male RJ 45 Male T indict Mion teh 2 Sp e a tees 1 OR Re ere E ee 2 3B dee sie Racks wii exw ee 3 Crossover Cable Oaia a a ianed ia dei a 6 at RJ 45 Plug Hub 2222255 Hub RJ 45 Male RJ 45 Male Leewtetdaa chet dea wend 3 ee eee ee eee 6 3 giuran en a Liae 1 O ae Eva na euE ganna 2 8 Port Ethernet Hub w SIC Sot 3 INSTALLATION To install the LAN Master T8 Hub e Unpack the LAN Master T8 Hub e Install on flat surface e Connect 10BaseT Cable at Front e Optionally install Slide In Cards e Optionally install Slide In Card cable e Connect LAN Master T8 Hub to power Direction is provided in the pages that follow Unpacking the LAN Master T8 The LAN Master T8 Hub packing contents should include the following Item Part Number LAN Master T8 E TBT HB 0802 Power Cord 3344 3347 3348 3349 or 3523 depending upon power configuration in country where installed User s Guide 7364 In addition any of the following optional SICs may be included Item Part Number Thinnet Coaxial E CX SIC Fiber Optic E FRL SIC Twisted Pair E TBT SIC Female AUI E AUI DT SIC Male AUI E AUI DC SIC Bridge E BR SIC Redundant Fiber Optic E FL RED SIC 7 LAN Master T8 Female AUI Connector 10Base5 Connection The female AUI card E AUI DT SIC provides a female AUI connector for connection through an AUI drop cable to the 10Base5 port on a transceiver
14. n RMA number can be requested from TN or your distributor This RMA number is only issued for item s after 90 days from the original ship date but prior to the expiration of the period The retum item s must be shipped freight prepaid by the End User or Distributor to the TN address below TRANSITION Networks Inc 6475 City West Parkway Eden Prairie MN 55344 USA TRANSITION Networks will repair or replace the unit at its discretion and cover the cost of the rebum freight to the distributor or End User who was issued the RMA number e A Material Repair Authorization MRA number can be requested from TN or your distributor This MRA number is only issued for out of warranty item s The retum item s must be shipped freight prepaid by the End User to the TN address above The sender will be contacted by TN after the item s have been received inspected and a cost estimate of the repair has been determined The repair charges may be billed with approval through your distributor or prepaid C O D basis through the End User In either case charges will include freight both ways and repair charges The retum authorization number is only valid for 60 days from the date of issuance Please list this number on the outside of the carton and or packing list Include a copy of the original invoice or packing dip to expedite processing D Restocking Fee All retums for credit must be received in the same condition as originally shi
15. nc Trademark Notice All registered trademarks and trademarks are the property of their respective owners LAN Master T8 TN s total liability in connection with the products and installation thereof to all persons and from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party with respect to a product manufactured in accordance with customer s specifications C Return Procedure Before TN item s can be returned a Credit Returm Authorization CRA Retum Material Authorization RMA or Material Repair Authorization MRA number must be obtained from TRANSITION Networks TN or the distributor of origin Locate the serial number s of the item s to be returned From the item serial number TN or the distributor will verify the retum status and provide the appropriate number to the End User The three types of return numbers are listed below e A Credit Retum Authorization CRA number can only be requested from your distributor This CRA number will only be issued to distributors for item s within 90 days from the original ship date Under no circumstances will a CRA number be issued directly to the End User The retum item s must be shipped freight prepaid by the End User or the Distributor to TN e A Retum Material Authorizatio
16. nd in maintaining the LAN Master T8 8 Port Ethernet Hub w SIC Slot Pocket Hub contact Technical Support 800 260 1312 or your local distributor 8 Port Ethernet Hub w SIC Sot 16 4 OPERATION The LAN Master T8 8 Port Ethemet Hub w SIC Slot normally requires no intervention beyond occasionally monitoring the Power and Port Indicator LEDs Port Indicators Link Partition Monitoring Power LED The green Power LED is illuminated when the LAN Master T8 8 Port Ethemet Hub w SIC Slot is connected to external power Monitoring Port Indicator LEDs Each of the eight twisted pair ports has an associated LED e steady green data traffic is active on link flashing green port has been partitioned 15 LAN Master T8 2 STE CONSIDERATIONS The site for the LAN M aster T8 8 Port Ethernet Hub w SIC Slot must provide e AC power outlet for each LAN Master T8 8 Port Ethernet Hub w SIC Slot e Adequate ventilation e Standard environmental conditions e Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally e The twisted pair cables should not run in the same conduit with power line cables e Phone lines should be separated from data cables e Flator silver satin wires should not be used e If using Slide in Card SIC connection between LAN Master T8 Hubs the maximum cable distances are
17. pped If TN determines that a returmed product is damaged due to improper Packaging or if the item is functional and returned because of customer error inability to use etc TN reserves the right to charge a minimum 15 10 00 minimum per item restocking fee the payment of which is a condition precedent to the repair and or retum of the product 8 Port Ethernet Hub w SIC Slot 20 Policy And Procedure A Limited Warranty TRANSITION Networks TN warrants for a period of two years with the exclusion of five years for passive balun products from the date of shipment to the original purchaser and at the original point of installation that products of TN s design will be free from defects in materials and workmanship and in conformity with TN s specifications TN s sole warranty with respect to products manufactured or assembled by TN in accordance with a customer s specifications is a two year warranty that such goods conform to such specifications These warranties do not extend to goods that have been subject to alterations misuse accident tampering improper maintenance improper installation or abuse THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TN AND TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEME
18. r 3 Connect male RJ 45 plug connector at other end of LOBaseT cable to DTE terminal RJ 45 jack connector using crossover cable orientation or to Hub RJ 45 jack connector using straight through cable orientation 11 LAN Master T8 Installing LAN Master TS on Hat Surface To install the LAN Master T8 on table shelf or other flat surface 1 Carefully tum LAN Master T8 to side 2 Install four 4 rubber feet e Remove protective paper from adhesive surface of rubber foot e Position rubber foot at bottom comer of LAN Master T8 e Secure rubber foot to LAN Master T8 surface e Repeat for remaining rubber feet 3 Return LAN Master T8 to upright position 8 Port Ethernet Hub w IC Slot Connecting 1LOBaseT Cable at LANMaster T8 Front mm crossover configuration using straight through cable LILLLii1 LILLLii1 straight through cable straight through cable a L To connect 1OBaseT Cable to RJ 45 connectors at the LAN Master T8 front 1 Locate or build LOBaseT cables with the following characteristics e 802 3 compliant See page 18 e straight through cable configuration See page 6 e male RJ 45 plug connectors installed at both ends of cable 2 Connect male RJ 45 plug connector at one end of 1OBaseT cable to LAN Master T8 RJ 45 jack connector 3 Connect male RJ 45 plug connec
19. tor at other end of 1OBaseT cable to DTE terminal RJ 45 jack connectors 4 IF CONNECTING TWO LANMaster T8s e Connect LAN Master T8s AT PORT 8 using steps 1 3 e Set the interface switch on one LAN Master T8 to MDI and the interface switch on the other LAN Master T8 to MDI X Port 8 Setting Installing Side In Cards CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing Slide In Cards Failure to observe this caution could result in circuit board failure NOTE Slide in Cards can be hot swapped To install a Slide In Card 1 Determine if the Slide In Cards has an SQE switch and if so verify that the SQE switch is in the OFF position NOTE SQE switches must be set to the following OFF positions UTP STP card Thinnet card AUI DCE TOWARD 20 pin edge connector TOWARD 20 pin edge connector AWAY FROM 20 pin edge connector AUI DTE card Not Applicable Fiber Optic card TOWARD 20 pin edge connector Redundant Fiber Optic SQE jumper setting on board should be labeled if not holding card with 20 pin edge connector at top jumper two leftmost pins Bridge Not Applicable 2 With the Slide In Card components facing up carefully guide the Slide In Card along the card guides until the Side In Card connector meets the the LAN Master T8 backplane 3 Firmly push the card into the slot until the Slide In Card faceplate is flat against the LAN Master