Home
TOA Electronics C-IF500 Network Card User Manual
Contents
1. cha Termination switch Termination switch Termination switch OFF ON OFF T EPA E An 1 Combination 0 0 Ch 32 E Ch 33 7 Ch 62 Termination switch Termination switch Termination switch Connection cables Recommended cable type CPEV S type shielded twisted pair cable thicker than 0 65 mm in diameter If multiple cameras are connected to a single terminal the total of each cable distance between connected equipment must be 1 2 km or less do p C IF500 camera camera camera SEM bos a b c lt 1 2 Termination switch setting Set the unit s termination switch to ON when the unit and the C RM500 Remote Controller are connected in a matched pair in the system Make sure that the termination switches of the cameras connected to the system are set as follows Cameras other than the last connected camera Termination switch OFF Last connected camera Termination switch ON Interface unit Combination Combination _ Combination C IF500 camera camera camera Terminal switch Terminal switch Terminal switch OFF OFF ON 5 3 Star Connection Connect the Combination camera s control cable to the unit s Slave Connection Terminal making sure to match their polarities Camera control terminal Remote controller GND C RM500 Shielded twisted pair ca
2. JAPAN SER 02A4000001 5 CONNECTIONS 5 1 System Examples Example 1 Smart switcher Monitor TV TTTITIT Ooooo0000 Combination camera 0000 00 22222 Remote controller Combination camera Example 2 Combination camera Monitor TV Multi switcher 10 2909090909090 u unanunuun HABBBEBBEHBEBUH uu a 9 I mm Te maj C IF500 Remote controller 5 2 Connecting 32 or More Combination Cameras Connect the Combination camera s control cable to the unit s Slave Connection Terminal making sure to match their polarities Camera control terminal Remote controller 9405 500 Shielded twisted pair cable Termination switch ON MASTER SLAVE C IF500 CINA OUT B4 GND 6 0 GND GND GND GND TERMINATION lel ooo gle glojo o 90220 5 5 Caution Up to 31 C CC501 C CC504 C CC551 or C CC554 Combination Camera can be connected to each Slave Terminal A D a i I fal cp PS E a 7 v 1 j Combination 0 0 X camera E i T
3. When Installing the Unit Never plug in nor remove the power supply cord with wet hands as doing so may cause electric shock When unplugging the power supply cord be sure to grasp the power supply plug never pull on the cord itself Operating the unit with a damaged power supply cord may cause fire or electric shock When moving the unit be sure to remove its power supply cord from the unit Moving the unit with the power cord connected may cause damage to the power cord resulting in fire or electric shock When removing the power cord be sure to hold its plug to pull Do not block the ventilation slots in the unit s cover Doing so may cause heat to build up inside the unit and result in fire Avoid installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Use the dedicated AC adapter for the unit Note that the use of other adapter may cause a fire Contact your dealer as to the cleaning If dust is allowed to accumulate in the unit over a long period of time a fire or damage to the unit may result If dust accumulates o
4. Z4 TOA INTERFACE UNIT INSTRUCTION MANUAL C IF500 N TABLE OF CONTENTS 1 SAFETY PRECAUTIONS 5 CONNECTIONS 5 1 System Examples 5 2 GENERAL DESCRIPTION 5 2 Connecting 32 or 3 FEATURES More Combination Cameras 6 4 NOMENCLATURE AND FUNCTIONS 5 3 Star Connection 7 FONE idee e 6 SPECIFICATIONS 8 0 Please follow the instructions this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference TOA Corporation 1 SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included We also recommend you keep this instruction manual handy for future reference Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling Before operating your product read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards Do not expose the u
5. ble Termination switch OFF MASTER SLAVE C IF500 CINA OUTS cD4 GND GND TERMINATION GND GND GND fol OO OC JO Combination camera Ch 1 Ch 2 Ch 3 Ch4 ba switch Termination switch Termination switch Termination switch ON ON ON Termination switch ON MASTER SLAVE C IF500 OUT r a cDa GND GND TERMINATION GND GND GND GND pes tae Combination camera Ch5 Ch 6 Ch 7 Ch 8 NN switch Termination switch Termination switch Termination switch ON ON ON Connection cables Recommended cable type CPEV S type shielded twisted pair cable thicker than 0 65 mm in diameter The maximum cable distance between the Combination camera and each Slave Connection terminal is 1 2 km Termination switch setting Set the termination switches of all connected cameras to ON Make sure that the unit s termination switch is set as follows Units other than the last connected unit Termination switch OFF Last connected unit Termination switch ON 6 SPECIFICATIONS Power Source 12VDC Current Consumption 100 mA External Control Master RS 485 screwless connector terminating resistance 100 Q switch ON OFF Slave 4 channel RS 485 screwless connect
6. ect gets into the unit If the unit falls or the unit case breaks If the power supply cord is damaged exposure of the core disconnection etc If itis malfunctioning no image appears To prevent a fire or electric shock never open nor remove the unit case as there are high voltage components inside the unit Refer all servicing to your nearest TOA dealer Do not place cups bowls or other containers of liquid or metallic objects on top of the unit If they accidentally spill into the unit this may cause a fire or electric shock Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or electric shock Do not touch a plug or antenna during thunder and lightning as this may result in electric shock Underwriters Laboratories Inc UL has not tested the performance or reliability of the security aspects of this product UL has only tested for fire shock or casualties as outlined in UL s Standard s for Safety UL Certification does not cover the performance or reliability of the security hardware and security operating software UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY RELATED FUNCTIONS OF THIS PRODUCT CAUTION Indicates a potentially hazardous situation which if mishandled could result in moderate or minor personal injury and or property damage
7. ller s control signal into 4 signals Can convert the C RM500 s control signal level into the RS 232C signal level Connecting the unit between the C RM500 and the Combination camera permits star connection between the Remote Controller and camera Front 4 NOMENCLATURE AND FUNCTIONS 1 Power indicator POWER Lights when the power is supplied 2 Transfer rate setting switch MODE Sets the transfer rate of the data to be transmitted via the unit Transfer Rate 1 2 3 4 38400 bps ON ON ON ON 19200 bps OFF ON ON ON 9600 bps ON OFF ON ON 4800 bps OFF OFF ON ON Rear 4 2 D Data transmission indicator TX Lights when data is transmitted from the Slave terminal Data reception indicator RX Lights when data is received from the Slave terminal DCIN 12V MASTER 12V OCD GND GND CINA OUT GND GND TERMINATION 8 RS 232C GND GND GND GND looo SE ae ojo 555 655555 SLAVE r A f B ca 0 6 5 adapter input terminal Connect the AC adapter to this terminal 12 V DC power input terminal Please connect with the power supply other than the AC adapter by the cable that attached the supplied clamp filter 2tu
8. n the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely Unplug the power cord from the unit for safety purposes when cleaning or leaving the unit unused for 10 days or more Doing otherwise may cause a fire or electric shock C IF500 complies with Part 15 of the FCC Rules Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications Any modifications made to this device that are not approved by TOA Corporation may void the authority granted to the user by the FCC to operate this equipment 2 GENERAL DESCRIPTION The TOA C IF500 Interface Unit is a splitter for control signals to be used when controlling 32 or more TOA Combination Cameras connected to the TOA C RM500 Remote Controller 3 FEATURES Can split the C RM500 Remote Contro
9. nit to rain or an environment where it may be AN WARNING splashed by water or other liquids as doing so may result in fire or electric shock N WAR N Indicates potentially hazardous situation which if mishandled could result in death or serious personal injury When Installing the Unit Use the unit only with the voltage specified on the unit Using a voltage higher than that which is specified may result in fire or electric shock Do not cut kink otherwise damage nor modify the power supply cord In addition avoid using the power cord in close proximity to heaters and never place heavy objects including the unit itself on the power cord as doing so may result in fire or electric shock Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted surface Doing so may result in the unit falling down and causing personal injury and or property damage To prevent the electromagnetic wave from badly influencing medical equipment avoid installing the unit in close proximity to the medical equipment When the Unit is in Use Should the following irregularity be found during use immediately disconnect the power supply cord from the unit and contact your nearest TOA dealer Make no further attempt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic obj
10. or RS 232C D sub connector 9 pin male Display Power LED indicator communication LED indicators TX RX Maximum Cable Distance RS 485 1 2 km RS 232C 10 Communication Speed 4800 bps 9600 bps 19200 bps 38400 bps Operating Temperature 10 to 50 C Operating Humidity Under 90 no due condensation produced Finish Panel Aluminum black 30 glossy paint Case Pre coated steel plate black 30 glossy Dimensions 210 w x 46 h x 284 1 d mm Weight 1 4kg Notes The unit cannot be used in the system with the transmission reception switching interval of 2 bytes or less or where transmission signals could be simultaneously sent out from multiple slave terminals The design and specifications are subject to change without notice for improvement Communications cannot be made between slave terminals 2 Applies to the system where the unit and Combination camera are connected a matched pair Represents the total of connected cable distances if multiple Combination cameras or Interface units are connected in the system when the CPEV S cable thicker than 0 65 mm in diameter is used Optional Equipment MB 15B BK Rack mounting bracket for rack mounting one C IF500 unit MB 15B J Rack mounting bracket for rack mounting two C IF500 units E Printed in J Corporation
11. rn xh power suppl GND P clamp filter Please attach a clamp filter to the nearest possible position of this controller Ground Terminal GND Please be sure to ground Master connection terminal MASTER Connects to the C RM500 Remote Controller to split the control data transmitted from the C RM500 9 10 11 a Terminating resistance switch TERMINATION Set this switch to ON when connecting the C RM500 However there is a case that the switch is used in the OFF position depending on the connection method Refer to p 6 for details RS 232C terminal SLAVE RS 232C Converts the data received at the Master Connection Terminal into the RS 232C signal level and sends out the converted signal The RS 232C Terminal also converts an input signal to the RS 232C terminal into the RS 485 control signal and outputs the converted signal from the Master Connection Terminal Slave connection terminal SLAVE A D Splits an input signal to the Master Connection Terminal into 4 and sends out the split signals Caution Up to 31 C CC501 C CC504 C CC551 or C CC554 Combination Camera can be connected to ea ch Slave Terminal A D Connect the DC power supply of 12 V over 100 mA which suited CE standard to either input terminal Bottom INTERFACE UNIT model 500 120 __ 125 2100mA Class 12 Rating label Yd Corporation MADE