Home
Samsung SW81ASP Washer User Manual
Contents
1. DOWN DISCHARGE INTO HALL INSTALLATION CONVERTING COOLER TO SIDE AIR DISCHARGE F1G 4 Remove both louvers and set them where they will not fall See pg 11 Taking Off Louver Remove four grille clips on side opposite motor Remove a reservoir by pushing the water cros sover tube from the grommet and lifting out the reservoir Remove the second reservoir as above Remove the screw that holds the wiring box Remove inch diameter and inch diameter knockouts Remove two plastic plugs Loosen screw holding pad motor receptacle bracket slide bracket up and detach from cabinet flange Repeat on other side 9 Turn cooler to side outlet position Figure 5 REASSEMBLY AS SIDE OUTLET COOLER Fig 5 Move wiring box to new location Secure wiring box with screw removed at disassembly Install four disassembly install two receptacle brackets removed at disassembly Install two plastic plugs removed at disassembly 6 Assembly reservoirs crossover tube and louv ers after the cooler is installed in location Use soap or detergent to lubricate crossover tube before inserting into grommet DO NOT USE OIL louver clips removed at ROUTE WIRES INSIDE OF PANEL DOWN OUTLET INSTALLATION LIFTING COOLER CAUTION DO NOT LIFT ON THE LOUVERS REMOVE THE LOUVERS BEFORE LIFTING DO NOT LIFT ON THE CENTER OF THE
2. owners manual MODEL NO 661 623920 661 624420 661 624530 661 624630 661 624670 e Installation e Operation Repair Parts SEARS ROEBUCK AND CO Chicago IL 60684 U S A 30780 6 CONTENTS INSTALLATION COOLER USE Tools and Supplies You Need 3 Cooling Your Home DER Le air te AG Safety Rules var 3 Cooler Care Data FN LES ere ad puted ies ee 3 Spring Summer and Fall Care 11 Locating Your Cooler 4 Taking Off and Putting On Grills 41 Converting to Side Outlet o5 Taking Off Pad nemi 12 Mounting Cooler 6 Cleaning 42 Electrical Connections Sr Putting on Pad 13 Final Assembly and Adjustment 8 Qiling EE A eee eg ee 13 Startup Check List 9 Blower Belt Adjustment 43 REPAIR PARTS 14 NEED ADVICE MISSING PARTS CALL MANUFACTURER FIRST Just dial this toll free number 1 800 643 2742 to get facts fast Call Monday through Friday 8 00 A M to 5 00 P M Central Time Our experienced Hotline Service Representative can e Answer installation questions e Provide prompt shipment of missing parts YOUR SATISFACTION IS OUR NUMBER ONE PRIORITY Reminder The person you will be talking to is Not a SEARS store employee and cannot handle exchanges arrange service calls etc This must be handled through your Sears Store or Catalog Order Department This toll free number is for technical assistance only FULL ONE YEAR WARRANTY ON SEARS EVAPORATIVE COOLER One yea
3. CABINET FLANGES 6 MOUNTING COOLER Fig 7 1 Prepare duct to fit model used See outlet size specifications on page 3 2 Cut opening in roof or wall to fit duct opening on cooler and box in cpening 3 Install duct and secure to boxed in opening frame Allow the two inches to fit into cooler outlet Allow duct length for cooler bottom to be 4 inches above roof at closet point 4 Install flashing on roof or wall to prevent water entry 5 Measure cooler and lay out mount location MAXIMUM HEIGHT FOR STAND SIDE EDGE TO ALLOW RESERVOIR CLEARANCE FLASHING DUCT SPACER Ve DAD ABOUT THICK Litt at cabinet corners The cooler may be tifted by putting a bar or strap through the panei hole and lifting by means of the bar or strap Fig BOXED OPENING RISER DUCT 4 INCHES MINIMUM NOTE THE BOTTOM EDGE NEAREST THE AIR OUTLET MUST FACE UP THE ROOF 6 Mount cooler on stand or pad Cooler must be level front to back and left to right Sears roof stand kits are available 7 Be sure to securely fasten four corners of cooler to stand or pad 8 Caulk duct to the cooler Caulk the flashing FLASHING ROOF STAND KIT PURCHASE SEPARATELY FLASHING BOXED OPENING RISER DUCT 2 INCHES ELECTRICAL CONNECTIONS Use only a Sears 32 6251 wall mounted switch The wiring must comply with local codes If you This new cooler does not require prewetting the are not familiar with the codes o
4. OUTLET 661 624630 6600ctm 661 624620 32 6295 661 624670 7200ctm 661 624670 32 6295 3 INSTALLATION LOCATING YOUR COOLER Your cooler has been shipped ready for installa tion in a down discharge position It can easily be changed to side discharge The cooler must be securely fastened to a frame or pad mount A roof kit is available from Sears A duct must be attached to the cooler outlet The duct must be the same size as the cooler outlet Sudden duct size changes will decrease the out put of your cooler The cooler installation must comply with local codes If you are not fully qualified to install a cooler get professional help Figure 1 shows locations for your cooler Be sure the intake louvers are clear of obstructions and are accessable for removal Do not locate the cooler near vent pipes chimneys or exhaust where odors or fumes may be drawn into the house The two drain holes on the cooler bottom must be elear to allow overflow or drain access SIDE DISCHARGE CONNECT TO HOUSE DUCTING WIRING BOX FIGURE 2 The wiring box is inside the cooler cabinet The electrical supply must be connected to the cooler power leads inside the box after the cooler in installed The wiring box is factory instalied for coolers used in the down air outlet position IF YOU INSTALL THE COOLER IN THE SIDE AIR DISCHARGE POSITION THE WIRING BOX MUST BE MOVED SEE PAGE 5 SERVICE BOX BEFORE STARTING WIRING a
5. 031 30105 30311 00 STD551231 50294 STD610803 30432 30551 08133 V30288 14864 501241 30686 STD503105 31086 32031 10 31984 30314 30238 01 30482 STD575026 1 STD575025 30418 01 30323 30148 30205 30202 27835 14982 1 29816 30585 1 32031 20 30552 29996 31985 02 WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION 1 PART NUMBER 3 MODEL NUMBER 2 PART DESCRIPTION 4 NAME OF ITEM 30439 50255 STD523107 581191 583054 STD503102 30557 30304 00 STD551131 STD541031 30105 3031 1 00 STD551231 50294 STD610803 30432 30551 08133 V30288 14864 501241 30686 STD503105 31086 32031 10 31984 30314 30238 01 30482 STD575026 STD575025 3048 01 30323 30167 30205 30202 27835 14982 29816 30585 32031 20 30552 29996 31985 02 DESCRIPTION Motor Plug Motor Tail Mount Machine Screw 5 16 18 X 3 4 Motor Pulley includes Key 6 Set Screw 5 16 18 X 25 Hex Socket Cup Point V Belt Motor Mount Lock Washer 5 16 Helical Spring Hex Nut 5 16 18 Clip Receptacle Mound Lock Washer 5 16 internal tooth Lock Washer Pe 8 18 X 3 8 Phillips Type Pad Motor Connector Machine Screw 5 16 18 x 3 8 Screw 1 4 14 x 3 8 Type B Bearing Mount Bushing Thrust Washer Screw 8 18 x 1 2 Type B Set Screw 5 16 18 Socket Overflow Drain Reservoir Grommet Puliey includes Key 24 Shaft Float and Valve Ferrule Compression Nut Water Shield Blow
6. 2 Ifthe amperage is less than the motor nameplate amperage loosen the pulley pitch adjustment screw turn the pulley turn clockwise tighten the screw and recheck the amperes Repeat as necessary to bring the amperage to the name plate rating 3 Ifthe amperage is too high turn the pulley coun IMPORTANT ter clockwise as required NOTE When checking amperage with the ammeter all louvers must be In place in the cooler otherwise incorrect setting of the drive pulley will occur 4 Adjust the belt tension as required See page 13 STARTUP INSPECTION Water line is connected securely and fittings and Before starting the cooler make sure all installations crossover tube grommets do not leak and adjustments are correct Be sure that o Float is adjusted for proper water level e Cooler is level and duct is sealed o Pulley alignment is OK Belt tension is OK See Cabinet is securely fastened to the mount page 13 e Cooler is grounded Electrical connections are e Pads are correctly installed See page 13 secure e Blower and both pad motors are plugged into e Blower wheel does not rub against housing receptacles Water supply is turned on e All louver clips are snapped tight STARTUP CHECK LIST To check out the installation follow this startup procedure Set the control to sach position and check operation per the following chart Be sure to open windows or vents OPERATION WITH SEARS SWITCH 32 6251 Five
7. 62 29862 29862 Roller Drive STD601103 STD601103 STD601103 STD601103 STD601108 Screw 10 32 x 30780 6 30780 6 30780 6 30780 6 30780 6 Owners Manual F642 1688 Rev 6 92 30338 30338 30337 30332 30332 Louver Assembly inciudes Keys 48 59 24971 1 24971 1 2497 1 1 2497 1 1 24971 1 Bushing Bottom Roller 523122 523122 523122 523122 523122 Splash Guard Cover 32 6256 32 6256 32 6257 32 6258 32 6258 Roof Stand Kit Optional 32 62562 32 62562 32 62562 32 62562 32 62562 Bleed Off System Optional 32 6251 32 6251 32 6251 32 6251 32 6251 32 6202 32 6202 32 6203 32 6204 32 6204 PROTECTIVE COOLER COVER Unillustrated Item included 5 Position Switch Optional Model Numbers 661 623920 661 624630 WHEN ORDERING REPA DERING REPAIR PARTS ALWAYS 661 624420 661 624670 GIVE THE FOLLOWING INFORMATION 661 624530 ue 1 PART NUMBER SEE REPAIR PARTS The Madet Number of your Evaporative Air Cooler will be 2 PART DESCRIPTION SEE REPAIR PARTS found on the cooler cabinet label 3 MODEL NUMBER 4 NAME OF ITEM EVAPORATIVE COOLER HOW TO ORDER REPAIR PANTE E AH parts listed herein may be ordered from any If the parts you need are not stocked locally your order will 7 ROEBUCK AND CO SERVICE CENTER be electronically transmitted to a Sears Repair Pats 7 Distribution Center for handling SEARS ROEBUCK AND CO CHICAGO IL 60684 U S A Form No F642 1688 Rev 6 92 Part 30780 6
8. AD Fig 21 THE PADS NEED NO PREWETTING amp Put the lower roller in pad Fit the lower roller into the botton slots in the frame Push the top roller through the pad Fit the roll end over the pad motor shaft drive block amp Push the top roller end into the bearing Turn the bearing arm to hold the roller TUCK THE PAD EDGES UNDER THE 2 GUIDES ON EACH SIDE Put the two small center rollers in place Snap the ends into the holders See lubrication instructions below OILING Fig 22 Use SAE 20 Non detergent motor oil once per year 1 FIN the two blower shaft bearing cups 9 Put two or three dropsinthe two oil fill tubes on the blower motor Motors without oi fill tubes have lifetime lubrication 3 Put two or three drops in the end bearing on each pad motor BLOWER BELT ADJUSTMENT Fig 23 CAUTION DO NOT ADJUST BELT TENSION BY CHANGING THE DIAMETER OF THE MOTOR PULLEY ADJUST BELT TENSION ONLY BY MOVING THE MOTOR BRACKET 1 If you can easily move the belt over 1 inch it needs adjustment 2 To adjust belt tension loosen the three motor mount bolts 3 Push the motor to tighten the belt until belt moves about inch with finger force 4 Tighten the three motor mount bolts SEARS REPLACEMENT PADS MODEL NUMBER SEARS PAD NUMBER 661 623920 42 6293 661 624420 42 6293 661 624530 42 6294 661 624630 42 6295 TN N Ny OIL HERE O
9. AD MOTOR PLUG t1 CARE OF YOUR COOLER TAKING OFF PAD Fig 19 1 Lift up the small roller ends to unsnap the two center rollers Puli out the two small rollers 2 Pull out and turn the top roller bearing arm to line up the slot a Lift edge of pad from under the guide and pull out the top roll end 4 Take out the pad and bottom roller which will slide out of the bottom slots CLEANING YOUR COOLER FIG 20 HELPS PREVENT MINERAL BUILD UP WARNING NEVER WASH YOUR COOLER INTERIOR WITH A GARDEN HOSE WATER MAY HARM THE MOTORS OR GET INTO YOUR HOUSE 1 DISCONNECT THE ELECTRIC POWER AT THE FUSE BOX 2 Remove the Louvers See page 11 3 Connect a garden hose to a water tray drain fitting Unscrew and remove the overflow pipe to drain the tray 4 Automatic cycling BLEED OFF KIT available Sears 32 62562 NEVER DRAIN WATER ONTO A ROOF WATER RESIDUE MAY CAUSE YOU TO SLIP OR MAY STAIN YOUR ROOF USE A DRAIN HOSE TO RUN WATER TO A RAIN GUTTER OR TO A DRAIN 5 Drain the other tray 6 Take off the pads if they are dirty or clogged 7 Use a sponge and mild detergent to wash the dirt or scale from the trays and grilles DO NOT GET WATER ON THE PAD MOTORS 8 If the pads are clogged with hard water deposits and dirt replace the pads See page 13 9 Put the overflow pipes and grillesin place See page 11 12 mm a GARDEN HOSE CARE OF YOUR COOLER PUTTING ON NEW P
10. ARRANTY in addition to any warranty extended to you on the Sears merchandise involved which warranty becomes effective the date the merchandise is installed should the workmanship of any Sears arranged installation prove faulty within one year Sears will upon notice from you cause such faults to be corrected at no atti tional cost to you INSTALLATION TOOLS AND SUPPLIES YOU WILL NEED Pliers e Screwdrivers e Adjustable Wrenches e Tubing Cutter 5 32 Hex Key Wrench Electric Drill e Drill Bits o Hammer e Duct Caulking 10 Sheet Metal Screws e Wiring Supplies as Required by Local Electrical Code e Level RULES FOR YOUR SAFETY 1 WARNING TO AVOID FIRE SHOCK AND SERIOUS PERSONAL INJURY FOLLOW THESE INSTRUCTIONS l The installation must conform to local codes and utility standards Use the National Electric Code if a local code does not exist Discannect the electric power EVERY TIME you work on your cooler When your hands are inside the cooler you risk injury if the cooler is accidently turned on from inside the home If you mount the cooler on your home roof remember these safety tips e amp Duct As Required a local sheetmetal shop can supply ducting Equipment Suitable for Installing Duct Through House Wall or Roof Water Connection Use Kit 62527 62528 or 62522 Saddle Valve See page 8 Connect Water line for further information explaining th
11. N EACH LOUVRE REPAIR PARTS KENMORE CONVERTIBLE DOWN FRONT OUTLET EVAPORATIVE AIR COOLER MODEL NOS 661 623920 661 624420 661 624530 661 624630 661 624670 REPAIR PARTS KENMORE CONVERTIBLE DOWN FRONT OUTLET EVAPORATIVE AIR COOLER MODEL NOS 661 623920 661 624420 661 624530 661 624630 661 624670 NOTICE Order by PART NUMBER not by Key Number Refer to the back cover of this manual for parts ordering information key N COON OUI CN a PART NUMBERS FOR MODEL NUMBERS of 661 623920 661 624420 1 661 624530 1 661 624630 661 624670 303 STD503102 STD304550 30439 50255 STD523107 32 61073 80316 STD503102 STD304580 30305 00 STD551131 STD541031 30105 30311 00 STD551231 50294 STD610803 30432 30551 08133 V30289 14864 501241 30686 STD503105 31086 32019 10 STD575025 30418 01 30322 30177 30205 30202 27835 14982 29816 30585 32019 20 30552 29996 31985 03 4 30439 50255 STD523107 32 61074 30315 STD503102 STD304640 30304 00 STD551131 STD541031 30105 30311 00 STD551231 50294 STD610803 30432 30551 08133 V30288 14864 501241 30686 STD603105 31086 32025 10 31984 30314 30238 01 30482 STD575026 STD575025 STD575026 30418 01 30323 30148 30205 30202 27835 14982 29816 30585 32025 20 30552 29996 31985 02 30439 50255 STD523107 32 61075 30315 STD503102 30557 30304 00 STD551131 STD541
12. Position Biower Pad Switch Motor Motors Off Low Vent High Vent Low Cool High Cool HOW TO USE YOUR COOLER HOW YOUR COOLER WORKS Your cooler evaporates water to cool air Evaporative air cooling is the same natural cooling that happens when a breeze springs up after a summer shower You feel cool because the rain water evaporates and carries away heat Your new cooler has a motor 1 driven blower 2 which draws outside air through pads 3 which are turned by drive motors 4 The pads turn through water in trays 5 filled by the water float valve 6 and water crossover pipe 7 Air passes through the pads is cooled by water evaporation and is sent into your home Figure 14 You may also run the cooler in Vent when you want fresh air and no cooling Relative humidity affects the cooling capacity of any cooler See chart to determine the maximum amount of cooling possible at your OUTSIDE RELATIVE HUMIDITY outside temperature and outside humidity 15 20 30 Figure 15 COOLING YOUR HOME Your cooler and window or vents are the two parts of your air cooling system Outside air is filtered and cooled goes through your home and carries away heat and household odors You control the air cooling flow to your rooms by opening doors windows or vents Figure 16 OUTSIDE TEMPERATURE You must have window door or vent openings to let air out when the cooler runs The total opening a
13. e different water hook ups Roof Stand Kit if cooler is roof mounted Cooler 661 623920 use 32 6256 kit Cooler 661 624420 use 32 6256 kit Cooler 661 624530 use 32 6257 kit Cooler 661 624630 use 32 6258 kit Cooler 661 624670 use 32 6258 kit 32 6251 5 position Wall Switch for Either New or Existing Pump Type Cooler Wiring Never install or service a cooler during a storm or high wind conditions You could be injured or lose or damage parts Never wear shoes with slick soles when you work on a roof You may slip when you least expect it Never drain water onto a roof Water residue may cause you to slip or may stain your roof Use a drain hose to run the drain water to a rain gutter or to a drain To avoid injury never use the cooler without connecting it to a house duct system or without a sturdy mesh guard over the outlet Cabinet Dimensions Alr Output Opening Operating Modet inches inches Lbs Weight No Helght Width Depth Height Width with water 661 623920 29 29 35 17 17 195 661 624420 29 29 35 17 17 190 661624530 33 33 37 19 19 235 DEPTH 661 624630 36 36 421 16 19 19 285 661 624670 36 36 4213 16 19 19 289 HEIGHT OUTPUT RATINGS Cubic Feet Per minute SEARS EVAPORATIVE PAD USAGE Modal Industry Medel Sears sus No Rating No Pad Number 661 623920 4500ctm 661 623920 32 6293 661 624420 4000ctm 661 624420 32 6293 BOTTOM 661 624530 5200ctm 661 624520 32 6294
14. er Wheel Baffle Junction Box Cover Junction Box Cupped Washer Lock Washer 8 Star Bushing Screw 8 32 x 7 16 Type T G Reservoir areen The Model Number of your cooler will be found on If the parts you need are not stocked locally your order will be electronically transmitted to a Sears Repair Parts Disbritution Center for handling the back side of your cooler KENMORE CONVERTIBLE DOWN FRONT OUTLET EVAPORATIVE AIR COOLER MODEL NOS 661 623920 661 624420 661 624530 661 624630 661 624670 PART NUMBERS FOR MODEL NUMBERS 661 624420 661 624530 661 624630 661 624670 ene eee DESCRIPTION 661 623920 501248 501243 501243 501243 501243 Collar 30433 30433 30433 30432 30432 Pad Motor Connector 30878 30878 30440 30441 30441 Motor Connector 30214 01 30214 01 30254 01 29738 01 29738 01 Louver 31047 31047 31047 31047 31047 Bearing 30206 01 30206 01 30250 01 29817 01 29817 01 Side Support 30224 01 30224 01 30242 01 29881 01 29861 01 Top Roller 30211 30211 30235 30119 30119 Roller 30212 30212 30237 30127 30127 Bottom Roller 32 6293 32 6293 32 6294 32 6295 32 6295 Evaporator Pad 30465 30465 30465 30465 30465 Screw 10 16 x 30233 01 30233 01 30256 01 29815 01 29815 01 Motor Side Support V30336 V30336 V30336 V30336 00061 Pad Motor 29862 29862 298
15. he ring nut Screw the overflow pipe into the drain fitting Repeat for the second tray NOTE INSTALL DRAIN FITTING INVERTED IF COOLER IS MOUNTEDONA PAD CUT OFF THE OVERFLOW PIPE TOP FLUSH WITH THE HEXAGONAL RING 2 Put in the float vaive side tray first The cros sover tube and grommet MUST be on the float vaive side Fig 12 3 Push the crossover tube into the grommet Use soap or detergent as a lubricant DO NOT USE OIL 4 Put the second water tray in place Push the crossover tube into the grommet ADJUST WATER LEVEL 5 Turn on the water Check the water level when the valve shuts off If the water level is above the tray water level mark bend the float rod down If the level is too low bend the rod up NOTE CHECK THE CROSSOVER PIPE GROMMETS AND ALL CONNECTIONS FOR LEAKS PUT LOUVERS ON COOLER See page 11 COMPRESSION NUT FERAULE RING a PRESSIO l NUT n FERRULE C ADAPTER OVERFLOW TT PIPE DRAIN FITTING WASHER WATER TRAY GROMMET INSTALLATION MOTOR PULLEY ADJUSTMENT Figure 13 NOTE ALL DUCT CONNECTED COOLERS MUST BE ADJUSTED Long or small air ducts have excessive air resistance which decreases air output and motor amperage You may compensate for this by adjusting the motor pulley Use a clamp type ammeter to check the motor amperage PITCH ADJUSTMENT SCREW 1 Check amperage at the white lead in the wiring box
16. om spurting and splashing ouiside ol the reservoirs Snap in the Splash Guard Cover as ifusirated below toiter nto ours barker igtetead atatfup LES AOLLER 15 Hu bak LOOSE FARTS BAG wom CABINET SPLASH GUARD COVER SNAP COVER INTO WATER SPOUT FO PREVENT WATER RS De i AT A FROM SPLASHING Pr Louse is CHE tg wets wati a BERR PE ae o d ST A FLOAT VALVE e E Sad remover eee a WATER SPOUT vA SS fat clarity me i jb So eee ee WATER FLOAL a Ko cae TWST FLOAT BY HAND C s _ COMPRESSION ps Guta Potter POSITION AS HLUS teat WHH NARROW BIDE is A2 RING NUT THE VERTICAL POSITION en WASHER INSTALLATION FINAL ASSEMBLY AND ADJUSTMENT PUT FLOAT VALVE IN COOLER Put the float valve through the spout hole and cabinet hole Tighten the ring nut Be sure the float moves straight up and down TURN THE FLOAT UNTIL A NARROW SIDE IS UP Snap the Splash Guard Cover into the Water Spout as shown The Water Spout and Splash Guard Cover are provided to prevent water from spurting and splashing out side the Water Reservoir CONNECT WATER LINE For outdoor Hook Up use 62527 Copper Hook Up Kit or 62528 Plastic Hook Up Kit Both kits contain ali necessary fittings to connect water to cooler For indoor kit use copper tubing and 62522 self pierc ing saddle valve eed IN OVERFLOW PIPE Fig 11 Push the drain fitting through the washer and water tray hole Tighten t
17. r from the date of purchase when this Kenmore Roto Belt evaporative ait cooler is installed and maintained according to our instructions Sears will repair defects in material or workmanship free of charge same period of time You pay for labor THROUGHOUT THE UNITED STATES FIVE YEAR LIMITED WARRANTY Ail Sears Kenmore Roto Belt cooler cabinets and blower housings are warranted against rusting out and becoming inoperative after one year and through five 5 years from the date of purchase Sears Roto Beit cooler water reservoirs and louvers are warranted also against leaking and deterioration due to water corrosion for the WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER This warranty gives you specific legal rights and you may also have other righ s which vary from state to state SEARS ROEBUCK AND CO DEPT 698 731A SEARS TOWER CHICAGO IL 60684 Note Replacement of filter pads is normal maintenance and is not covered in the warranty SEARS INSTALLATION POLICY Ait installation labor arranged by Sears shall be per formed in a nee workmanship manner in accordance with generally accedpted trade practices Further all installations shall comply with ail local laws codes regulations and ordinances The customer shall also be protected during installation by insurance relating to property damage Workmen s Compensation and Pub lic Liability SEARS INSTALLATION W
18. r wiring practi pads before starting cooling and does not havea ces get professional help pump Existing switches with pump only posi Hon are not usable NEW INSTALLATIONS OR CAUTION SHUT OFF THE ELECTRIC COOLER CHANGEOUT INSTALLATIONS POWER AT THE FUSE BOX BEFORE Use Sears 32 6251 Switch which is suitable for BEGINNING THE WIRING either new installations or existing installations When installing a cooler or existing installation five wires must go to the cooler including grounding connector There are two cool posi tions and two vent positions Figure 9 shows how to wire the 32 6251 switch WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE nn FACTORY WIRING mens PELE WIRING CE the em are mee met rm one BLACK WALL BOX SWITCH RIBBED COOLER JUNCTION BOX FLOAT VALVE INSTALLATION INSTRUCTIONS INSTALLATION OF OUTSIDE ROLLERS His of ine Utmost Importance that the Floal Valve Splash Guard and Splash Guard Cover be installed exactly as described in the illustration below 1 The Fioat Valve Must be installed with Ihe narrow side of the foal in the vertical positon H nat installed this way the Hoat will hang up LPATS HEESE and cause the reservoir drain pipes to overtiow ahasay oUnI 4 us NOTICE TO INSTALLERS Ge suto RE outsede ra The water Spout and Water Spout Cover are provided to prevent water fr
19. reas you need are shown below MODEL TOTAL OPENING AREA 661 623920 11 Square feet minimum 10 Square feet minimum 12 Square feet minimum 661 624630 14 Square feet minimum 16 Square feet minimum 661 624670 TYPICAL AIR FLOW 16 CARE OF YOUR COOLER CAUTION ALWAYS UNPLUG YOUR COOLER BEFORE YOU WORK ON IT YOU COULD BE HURT IF THE COOLER IS TURNED ON WHEN YOUR HANDS ARE INSIDE THE COOLER SPRING CARE Clean your cooler See page 12 Oil your cooler See page 13 Put a new pad in if the old padis plugged with dirt or water hardness See pages 12 and 13 Check belt tightness See page 13 SUMMER CARE Drain and clean the cooler every two months if your water is hard or the air is dusty You may prolong pad life in many hard water areas If you drain the water tray every two to three weeks See page 12 Preventing mineral build up FALL CARE Drain the cooler and water line to prevent freezing damage See page 12 Clean the cooler See page 12 Cover the cooler Sears has covers to fit your cooler TAKING OFF LOUVER FIGURE 17 PUTTING ON LOUVER Figure 18 1 Unsnap the six louver clips Use a small screwdriver 1 Put the louver bottom into water tray 2 Tilt out the louver at the top 2 Plugin the pad motor Unplug the pad motor plug 3 Close the louver 3 Take off the louver Snap the six clips onto the louver Set it where will not fail INSERT SMALL SCREWDRIVER UNDER CLIP PRY OPEN P
Download Pdf Manuals