1. punchdown terminal on the UNO S2 Keypad as shown matching the conductor colors to the connection color guide The keypad will not operate properly if the ter minations deviate from the required connection order A Caution A Take care when using an impact 110 punch down tool as this may overspread the con tact points Use of the impact tool may pro pel stray bits of wire and jacket into the key pad s chassis and possibly cause a short in the circuitry Gently shake or blow air through the keypad chassis to remove stray wire before the keypad is installed into the junction box INSTALLER GUIDE UNO S2 Keypad Connections OS Update Port The OS Update Port is is used to update the UNO S2 Keypad operating system software in the future When an update is released it will be available online through the Document Center at www russound com Look for the Technical Documents under Multi source Multi room products The program ming cable is available from Russound Part 2500 120633 Jumper Setting The jumper settings on the back of the UNO S2 Keypad can be set for Run and OS Update The jumper setting must be in the Run position before the keypad is mounted into the junction box and must remain set in Run to operate the keypad The jumper will be set to OS Update only while updating the keypad s operating systems 15 INSTALLER GUIDE IR Receiver Connection Back of UNO S2 O O
2. CD CD Russound O UNO S2 System Control Keypad 12V 12v BRA GND cR EXTERNAL IR STATUS IN GRAV CEIVER IN sla GND or BR Back of aE Le Russound 858 F D 4 CD SHIELD WIRED S 2 Russound TO GROUND em oO The UNO S2 keypad has an EXTERNAL IR RECEIVER IN terminal for connecting an external IR Receiver such as the PAIR WIRE Russound 858 SaphiR Eye or SaphiR Phantom Use 2 twisted pair wire with Ge one pair connecting GND GROUND o and IR SIGNAL and the other pair con necting ST STATUS and V 12VDC Connect the shield or drain to ground at the UNO S2 only 16 Technical Specifications Dimensions Weight Power Requirements CAT 5 Connection TECHNICAL SPECIFICATIONS 3 65 W x 1 125 D x 4 3 H 9 2 x 10 9 x 2 8 cm Fits 2 Gang UL CSA Approved Junction Box 9 oz 255 g 12 VDC 180mA 110 punchdown 17 18 WARRANTY Warranty Repair The Russound UNO S2 is fully guaranteed against all defects in materials and workman ship for two 2 years from the date of purchase During this period Russound will replace any defective parts and correct any defect in workmanship without charge for either parts or labor For this warranty to apply the unit must be installed and used according to its written instructions If service is necessary it must be performed by Russound The unit must be
3. keypad installed away from any direct sunlight plasma TV and low voltage lighting controls Also consider con venience when choosing a location Choose a place that is easily seen from the position where a person is most likely to be located Check whether or not you can route the wire to the location you have chosen Keypad Installation To install a double gang keypad you will need to use a UL CSA approved plastic INSTALLER GUIDE UNO S2 Keypad Location double gang electrical box Route CAT 5 wire to the junction box from the CAV6 6 Use the supplied 110 punchdown tool to connect each wire to its corresponding color labeled on the punchdown terminal See page 12 for details Ensure jumper setting on the keypad is in the RUN position Mount the keypad in the electrical box and attach the cover plate Repeat the steps until all keypads are installed 13 INSTALLER GUIDE UNO S2 Keypad Connections Punchdown Tool Jumper Setting back of keypad LT CAT 5 Connections back of keypad Punchdown Tool OS Update Port front of keypad 14 CAT 5 Connection The UNO S2 Keypad uses a 110 punch down terminal to provide a simple installa tion and strong connection for CAT 5 cable s eight conductors Punchdown ter minals require the use of a punchdown tool which has been provided with the key pad kit Attach the CAT 5 cable to the 110
4. to pack the unit in a corrugated container with at least three 3 inches of resilient material to protect the unit from damage in transit Before returning a unit for repair call Russound at 603 659 5170 for a Return Authorization number Write this number on the shipping label and ship to Russound ATTN Service 5 Forbes Road Newmarket NH 03857 Due to continual efforts to improve product quality as new technology and techniques become available Russound FMP Inc reserves the right to revise system specifications without notice 19 R Russound Russound 5 Forbes Road Newmarket NH 03857 tel 603 659 5170 e fax 603 659 5388 e mail tech russound com www russound com Rev 2 28 1141
5. UNO S2 Keypad aaa aa See ee R Russound E X 4 C00 SAFETY INFORMATION UNO S2 Keypad Git NES gt 14 Read Instructions All the safety and operating instructions should be read before the appliance is operated Retain Instructions The safety and operating instructions should be retained for future reference Heed Warnings All warnings on the appliance in the operating instructions should be adhered to Follow Instructions All operating and user instructions should be followed Water and Moisture The appliance should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool Wall or ceiling Mounting The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer Ventilation The appliance should be situated so that its location or position does not interfere with its proper ventila tion For example the appliance should not be situated on a bed sofa rug or similar surface that may block the ventila tion openings or placed in a built in installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appli ances including amplifiers that produce heat Power Sources The appliance should be connected to a power supply only
6. elect a disc or channel e g channel 45 Wait for the keypad to show the source name then press and hold the F1 or F2 within 15 seconds of setting the numeric selection to save the setting Command Keys The command keys allow control of the selected source at the UNO Keypad The command keys are activated with a press and release or press and hold to access secondary functions BOVOOO The User Menu allows the user to adjust the audio properties and control functions of a particular room The following keys are used to navigate and make changes while using the User Menu To enter the User Menu press and hold during normal operation To exit the User Menu press and release GQ Adjust feature setting increment Adjust feature setting decrement Go to next feature 9Go to previous feature View current feature setting The following features make up the User Menu BASS TREBLE LOUDNESS BALANCE TURN ON VOL BG COLOR 6 DO NOT DSTRB CD PARTY MODE FRONT A V IN Feature and Setting 1 BASS 10 lt Bass Flat gt 10 2 TREBLE 10 lt Treble Flat gt 10 3 LOUDNESS more bass fuller sound On or Off 4 BALANCE Left 10 lt Center gt Right 10 5 TURN ON VOL default room volume level 0 to 100 6 BG COLOR keypad background light Amber or Green or Off 7 DO NOT DSTRB On or Off default Do Not Disturb means do not disturb this room or selected
7. o Not Touch The UNO S2 With Wet Hands Do not handle the unit or power cord when your hands are wet or damp If water or any other liquid enters the cabinet take the UNO S2 to a qualified service person for inspection Care Periodically wipe off the front and side panels of the cabinet with a soft cloth Do not use rough material thin ners alcohol or other chemical solvents or cloths since this may damage the finish or remove the panel lettering TABLE OF CONTENTS UNO S2 Keypad Front Panele ann ERFREUT 4 5 Normal Operation erasana nn nanan nE REENER 6 US E eres eee eee 7 8 SELINgS eunana A A A HEINE 9 Update POr vsicccissiissccceicccrissaaasvcciiecctarsasavvadiiecctatsacavvidedssctitvaaannncee ds 10 REE ea 11 Keypad LOCATION a rer 12 13 Keypad Connections nennen 14 15 IR Receiver Connection eeeesssseeeeennnnsssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsennnnn 16 Technical Specifications ccccccccessssseeeceeeeeeessssseeeeeeeeecessnsneeeeeeeeeees 17 Wealainty nennen nannten 18 19 USER GUIDE UNO S2 Keypad Front Panel Ne BE BE BSG USER GUIDE UNO S2 Keypad Front Panel LCD PANEL 12 character backlit display shows status of the room source volume and more SOURCE SELECT BUTTON Scrolls through the sources directly connected to the CAV6 6 Press and hold brings up the USER MENU for Loudness Bass Treble etc VOLUME UP DOWN BUTTONS Raises and lowers the volume for the room IR RECEIVER Receive
8. of the type described in the operating instructions or as marked on the appliance Grounding or Polarization Precaution should be taken so that the grounding or polarization means of an appliance is not defeated Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs receptacles and the point where they exit from the appliance Object and Liquid Entry Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through the openings Damage Requiring Service The appliance should be serviced by qualified service personnel when the power supply cord or the plug has been damaged or objects have fallen liquid has been spilled into the appliance or the appliance has been exposed to rain or the appliance does not appear to operate normally or the appliance has been dropped or the enclosure is damaged Servicing The user should not attempt to service the appliance beyond that described in the operating instructions All other servicing should be referred to qualified service personnel Precautions 1 Power WARNING BEFORE TURNING ON THE POWER FOR THE FIRST TIME READ THE FOLLOWING SECTION CAREFULLY All models are designed for use with either AC120V 60Hz or AC240 50Hz voltages The unit will autoswitch to either of these voltages D
9. oom 9 FRONT AUX A V IN Enabled Disabled Allows the system to select a seventh source option through the controller s front panel AUX connection for use with cam corders game consoles etc INSTALLER GUIDE UNO S2 Keypad Update Port fo nn O WO O00 __9 DATA RS 232 DATA RS 232 GND N C N C 1 SETUP BUTTON Activates Installer Setup Mode for the UNO S2 keypad A OS UPDATE PORT Port used for UNO keypad OS software updates INSTALLER GUIDE UNO S2 Keypad Rear Panel O Q amp RIRussoun NEWMARKET NH U S A run A p 05000 NO RESET UNO S2 System Control Keypad 2v BR 12V BRW GND GR EXTERNAL IR STATUS IN GRW RECEIVER IN ONDI OR kd 2 SE IR OUT ORW SIE COMA BL 5 LE COMB Buw No O EXTERNAL IR RECEIVER IN CONNECTOR Connection for an external IR Receiver OS UPDATE JUMPER Selects Run or OS Update mode RESET BUTTON Reset whenever changing from RUN to OS update 110 PUNCHDOWN CONNECTOR Termination for CAT 5 connection between the UNO S2 Keypad and the CAV6 6 controller m INSTALLER GUIDE UNO S2 Keypad Location Plastic Double Gang PA Box G gt UNO S2 Back Plate Screwless 12 Cover Plate The best infrared remote performance is achieved with the
10. pressing and holding for 3 seconds after an ini tial room has been turned on An All Off command can be issued to all rooms by pressing and holding after the room has been turned off System On Indicator When the room is off but the system is on in another room is illuminated by a green backlight and the SYS ON icon remains visible USER GUIDE UNO S2 Keypad User Menu Source Select Button scrolls through the six A V source inputs and the Aux source To change sources press and release As the sources are sequentially selected each source s name appears on the keypad LCD panel When a source is selected in more than one room the SHARED icon will appear on all UNO Keypads using that source is also used to enter the User Menu with a press and hold action See next page for User Menu Volume Up Down Buttons A The room s audio output is adjusted using CG F1 and F2 Buttons The and buttons are user favorite presets These presets can be selected at any time to recall source selection vol ume favorite channel disc etc To store a favorite preset first adjust the room set tings and select a source to be stored Next press and hold the desired or continued USER GUIDE UNO S2 Keypad User Menu button until SAVED is displayed on the LCD panel Now a press and release of the button will recall the favorite preset To set a favorite numbered disc or channel use or to s
11. returned to Russound at the owner s expense and with prior written permission Accidental damage and shipping damage are not considered defects nor is damage resulting from abuse or from servicing by an agency or person not specifically authorized in writing by Russound This Warranty does not cover e Damage caused by abuse accident misuse negligence or improper installation or operation e Power surges and lightning strikes e Normal wear and maintenance e Products that have been altered or modified e Any product whose identifying number decal serial number etc has been altered defaced or removed WARRANTY Russound sells products only through authorized Dealers and Distributors to ensure that customers obtain proper support and service Any Russound product purchased from an unauthorized dealer or other source including retailers mail order sellers and online sell ers will not be honored or serviced under existing Russound warranty policy Any sale of products by an unauthorized source or other manner not authorized by Russound shall void the warranty on the applicable product Damage to or destruction of components due to application of excessive power voids the warranty on those parts In these cases repairs will be made on the basis or the retail value of the parts and labor To return for repairs the unit must be shipped to Russound at the owner s expense along with a note explaining the nature of service required Be sure
12. s IR signals and passes them to the controller and source equip ment Also used when operating the UNO Keypad by using the UNO LRC1 remote COMMAND KEYS Pressing the command keys controls the source equipment POWER BUTTON Turns room ON or OFF when pressed once press and hold a second time will turn on or off all CAV6 6 rooms F1 AND F2 BUTTONS Selects Favorite 1 or Favorite 2 preset user selected favorite settings per room USER GUIDE UNO S2 Keypad Normal Operation POWER STOP PAUSE FAVORITE 1 FAVORITE 2 SOURCE VOLUME UP VOLUME DOWN DISC CHANNEL UP DISC CHANNEL DOWN FORWARD REVERSE SHARED SYSON OOGVOOOSOOO v gt lt gt IR RECEIVER 1 MODE DND Do Not Disturb SHARED Same source selected in multiple rooms SYS ON Indicates system on PARTY Party Mode enabled MASTER Master Keypad in Party Mode FA 12 character display Volume Indicator 4 Indicates the middle of setting range Zone On Off Press and release to turn on the UNO System Keypad This also turns on the cor responding CAV6 6 s room and any pre sets previously assigned will be activated including settings for bass volume last source selected etc Press and release to turn off the UNO System Keypad This will also put the corresponding CAV6 6 s room into a standby state System All On Off An All On command is issued by
13. source This stops pages from being sent to this room stops an All Off All On or Party Mode command from affecting this room When another UNO Systems Keypad selects the same source a DND icon will appear alerting the user the source is in Do Not Disturb mode 8 PARTY MODE Master Enable Disable When in PARTY MODE the system is primari ly controlled by a MASTER Keypad Party Mode links all rooms to the same source which is selected by the Master Keypad room Any keypad in the system can become USER GUIDE UNO S2 Keypad Settings a Master Keypad if enabled but only one Master Keypad may exist at a time in Party Mode Selecting Master Keypad mode from another keypad will transfer Master Keypad control to that room and release it from the first When the source selected in the Master Keypad room is changed then the source for all rooms changes as well Volume level changes at the Master Keypad will be reflected in all rooms in Party Mode Non Master zones in Party Mode can tem porarily override Master Keypad volume level adjustments for their particular room prefer ence Fl and F2 favorite presets selected from the Master Keypad will be enabled in all rooms in Party Mode Master Keypad will not change Bass Treble or Loudness adjust ments for any other rooms other than the Master Keypad room Every other keypad will still operate its respective bass treble bal ance and loudness adjustments for that r

Download Pdf Manuals

image

Related Search

Related Contents

500388 - 00 - Manual Radiador Eléctrico Digital.indd  Philips 272G5DJEB  Téléchargez le contenu de la malle pédagogique  Laufrad KB0-1BT  Pure Digital Move 2500 Owner's Manual  Philips Digital audio cable SWA2570W  Manual - Valledelcauca.gov.co  WebEx Event Center User's Guide  Chap.3 MIG MAG Welding  