Rheem RS120-64BP Water Heater User Manual
Contents
1. See Figure 19b Solar Preheat 6 6 100 Utility Power Follow the instructions for the single tank system above All three ball valves above the heaters Nos 24 25 and 26 must have the valve handles placed in the horizontal position See Figures 19c 100 Utility Power and 19d Ais 7 ISOLATING THE MAJOR COMPONENTS AND SYSTEM SHUT DOWN PROCEDURES Your Rheem solar water heating system is designed so that the key components can be easily isolated for emergency repairs or routine maintenance By shutting a single valve you can isolate the entire system from the pressurized cold water supply line No 23 In the case of a storage tank or fitting leak immediately shut this valve and call your installation contractor for service The collector loop can be isolated from the solar storage tank by closing isolation ball valves Nos 5 and 10 If the pressure in this loop drops or you find a glycol leak shut these valves and contact your installation contractor Turn the circulating pump off by setting the controller to the off position In two tank systems the solar storage tank can be isolated from the back up water heater Set the valve handle on the three way ball valve No 24 to the horizontal position and close the isolation ball valve No 25 By closing these two valves the tank can be serviced or replaced The operation of the back up water heater will not be effected The back up water heater in two tank syste
2. through the solar collector The system pump efficiently circulates this heated fluid through the collector piping and integral tank heat exchanger As the HTF passes through the heat exchanger the heat in the fluid is transferred by conduction to the potable water in your solar storage tank As this process is continuously repeated during the average sunny day the temperature in your solar storage tank rises When the solar collector absorber plate is approximately sixteen degrees hotter than the temperature in the bottom of your solar storage tank SOUTH FACING PANELS ON EAST FACING ROOF SOUTH FACING PANELS ON SOUTH FACING ROOF COLLECTOR ORIENTATION the controller will turn the circulating pump on When the temperature difference has been reduced to eight degrees the controller automatically turns the pump off Both single and double tank Rheem systems are designed to provide three separate modes of system operation The system will 1 accommodate 100 solar operation 2 serve as a preheater to your solar storage tank or back up water heater or 3 bypass the solar collector and run 100 on utility power Section Six provides instructions for setting the system for automatic operation in each of these three modes The Dowfrost HD HTF protects your Rheem solar system against freezing Dowfrost HD can provide reliable freeze protection at temperatures as low as minus 30 Fahrenheit if properly applied and maintain
3. It is colored to differentiate the closed system fluid from the potable water supply This circulation of the heat transfer fluid is accomplished by a pump and sensors These solar water heaters are referred to as closed loop systems Your hot water is stored in a steel tank lined with porcelain enamel and thickly insulated to help maintain the water temperature throughout the day and night To ensure your hot water supply is never depleted the system is equipped with a backup heater or heating element When there may be insufficient solar energy you are still assured of all the hot water you will need While your system is one of the most efficient available there are two simple steps you can take to increase your water heating cost savings Introduction continued Keep the use of the Backup Heater to a Minimum You can save the most money on your water heating bills by using the backup heater on your system as little as possible If the sun shines brightly between I0 am and 3 pm enough heat will normally be generated to keep the water hot throughout the rest of the day and night However on days when the sky is cloudy or when large quantities of hot water are being used we suggest that the backup heater be left ON overnight to ensure adequate hot water the next morning Try to use Hot Water during Daylight Hours When possible schedule heavy hot water use such as dish washing laundry and showers in the mid
4. No 11 and place the other end in a five gallon bucket Open the valve and gravity will drain the heat transfer fluid into the bucket A licensed recycler reclaimer or incinerator must dispose of the Dowfrost HD DO NOT DUMP DOWFROST HD INTO A STORM SEWER ON THE GROUND OR INTO ANY BODY OF WATER BE CAREFUL THE HTF MAY BE EXTREMELY HOT 8 3 If the system is installed with an optional time clock make sure the clock is not preset to go ON during your absence If you have a mechanical time switch remove the on tripper from the clock face No 33 When you return home contact your service contractor to recharge the system with HTF After the system has been recharged set the controller to the automatic position Reset the time switch 9 MAINTENANCE AND TROUBLESHOOTING The following simple procedures are intended to optimize the performance of your Rheem solar water heating system and also to extend the life of the primary components 9 1 Fluid Quality It is extremely important to monitor the quality of the Dowfrost HD HTF on a periodic basis The chemical composition of the heat transfer fluid may change over time System pH must be maintained between 8 and 10 to avoid damage to the collector loop and absorber plate piping 9 2 The second most important component in your system at least from a longevity standpoint is often ignored and never seen We are referring to the sacrificial anode rod installed in you
5. VARY WITH INSTALLATION DRILL PILOT HOLE 3 4 OF BOLT DIA ST STL SLIDING NUT 1 5 8 X 4 SOLAR STRUT MOUNTING FOOT SET IN ROOFING MASTIC PITCH AND GRAVEL ROOFING ON ROOF ING FELT OVER DECK SHEATHING ON ROOF FRAMING SYSTEM BEAM OR RAFTER A A 0 500 SECTION SCALE COMPOSITION SHINGLE MOUNTING 4 2 Collector Tilt Optimal annual efficiency is achieved by tilting the solar collector at an angle that equals your latitude plus an additional 10 This tilt angle favors the lower winter sun when collector performance is at it s lowest and minimizes overheating during the hottest summer months The solar collectors in a two collector staggered mount installation must be spaced far enough apart to prevent winter shading Figure 2 and Table show the correct spacing between collectors to prevent shading on December 21 when the sun is at its lowest angle 4 3 Basic Mounting Procedures The Rheem solar collector in your Rheem solar system can be mounted in either a vertical or horizontal orientation on the roof See Figure 1 Although the collector is protected from freeze conditions by the glycol HTF and does not normally need to be drained it is still important to slope the collectors just slightly to allow for complete drainage if necessary The recommended slope is 1 4 per foot of horizontal run To ensure proper water drainage from the glazing the collectors must maintain a minimum angle from horizontal of a
6. be used alternate fluids could be hazardous to your health Once the components are plumbed you are ready to fill the solar storage tank with water and to charge the collector loop with a mixture of heat transfer fluid HTF and distilled or deionized water The use of 1 X 3 4 CC 90 ELBOW OR COUPLING RETURN LINE fig 15 1 CC A SUPPLY LINE 1 X 3 4 CC 90 ELBOW OR COUPLING COLLECTOR PLUMBING HORIZONTAL MOUNT regular tap water as a mixing agent is prohibited Proceed as follows 4 11 1 Begin by filling the solar tank with water Do this by opening the cold water isolation ball valve to the solar tank No 23 When the tank is filled inspect all threaded fittings and solder joints for leaks 4 11 2 Fill and pressurize the solar collector loop with water Begin by connecting a washing machine hose to the upper charge valve No 9 and fill the collector loop with water The isolation ball valve No 10 remains closed at this point While the hose is still connected to the upper charge valve and the water is running open the lower purge drain valve No 11 and let the water run out until it is free of impurities or debris that might have entered the piping as the components were plumbed Run the water long enough to eliminate any air bubbles that may be trapped in the system Close the lower purge drain valve The collector loop now has been subjected to city pressure and the pressure gau
7. contractors in accordance with SRCC Standard OG 300 and all applicable national state and local codes ordinances and regulations governing solar water heating installations as well as good trade practices Failure to follow the procedures and practices described in this manual can void the manufacturer s warranty for specific component parts This manual covers installations utilizing two Rheem solar collectors with a single solar storage tank and also two tank systems that include a solar storage tank and a conventional water heater For simplicity the singular form will be used throughout this manual when referring to all of these components and system permutations Frequent reference is made throughout this manual to specific component parts The placement of each component can be seen in system schematic figures 16 and 17 A description of each component and its function is found in Section 10 2 SYSTEM DESCRIPTION AND OPERATIONAL PRINCIPLE The key components in the Rheem solar water heating system include the solar collector solar storage tank with integral heat exchanger circulation pump differential thermostat expansion tank pressure gauge mixing valve and the non toxic propylene glycol heat transfer fluid HTF The Rheem solar collector is the heart of the system Simply stated when the sun is shinning heat energy is absorbed by the solar collector s all copper absorber plate and tranferred to the HTF circulating
8. installer show you the location of the circuit breaker and how to shut it off if necessary Turn off the circuit breaker if the water heater has been subjected to overheating fire flood physical damage or if the ECO fails to shut off Read this manual entirely before installing Do not attempt to repair or replace any part or operating the water heater of your water heater unless it is specifically recommended in this manual All other servicing should be referred to a qualified technician Use this appliance only for its intended purpose as described in this Use and Care Manual Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions OY READ AND FOLLOW THIS SAFETY INFORMATION XK CAREFULLY oa SAVE THESE INSTRUCTIONS PREFACE Let us first offer two words of grateful appreciation Thank You We sincerely appreciate your business Rheem also wishes to say thank you for going solar Solar water heating systems help to reduce our nation s dependence on polluting fossil fuels minimize the greenhouse gas emissions associated with conventional water heating and very importantly lower your monthly utility costs Your Rheem solar water heating system has been designed to meet exacting SRCC OG 300 certification requirements The components found in your system have been selected for their proven reliability longevity and performance in your specific regio
9. shall adhere to sound building safety and trade practices Special consideration must be given to building code requirements for the penetration of structural members and fire rated assemblies 3 3 The solar collector must be located in a structurally sound area of the roof that will be unshaded for the majority of the day all year round Adjacent buildings and trees should be checked for possible winter shading An instrument such as the Pathfinder can be used for solar site analysis 3 4 Before the installation the contractor shall inspe the condition of the roof and notify the homeowner of any existing roof damage or necessary repairs B ARE DESIGNATED IN INCHES 3 5 The homeowner and contractor shall confirm the location of all roof and ground mounted components in advance of the installation 4 INSTALLATION REQUIREMENTS SPECIFIC 4 1 Collector Orientation The performance of solar water heating systems e ct SIDE PITCH MOUNTING REVERSE PITCH MOUNTING in the Northern Hemisphere is optimized when the The collector should be unshaded by any permanent collector is mounted facing True South Performance obstacle between 9 00 a m and 3 00 p m on any day however suffers very little when the collector is of the year oriented no more than 45 East or West of True South 10 SOLAR COLLECTOR MOUNTING GROOVE 1 5 8 X 4 SOLAR STRUT W LOCKWASHER amp FLATWASHER LENGTH amp DIA
10. supply at the circuit breaker After the circuit breaker has been turned off remove the access plate on the storage tank or water heater and depress the red reset button on the thermostat If it clicks when depressed the heating element should fire 30 immediately when you reconnect the circuit breaker It the reset button does not click and you do not have hot water after one hour the heating element or thermostat may be defective Contact your installation contractor for service In two tank systems the conventional electric water heater will be wired for electrical back up The solar tank will serve solely as a storage tank and will not be wired 10 Rheem SYSTEM COMPONENT PARTS See Figures 16 and 17 for the location of the specific components numbered below 1 Rheem Solar Collector s Absorbs the sun s heat energy and transfers this heat to the HTF circulating through the collector Provided 2 Collector Sensor Wired to the system controller Works in conjunction with the tank sensor to automatically turn your circulating pump on and off at preset temperature differentials Provided 3 Tank and Line Thermometers Used to determine proper system operation Line thermometers will show an approximate 5 12 temperature dif ference between the collector supply and return lines on sunny days In a single tank system the tank thermometer will read the temperature of the water after the mixing valve feeding your fix
11. AP14490 12 08 Safety Information Introduction tee 3 4 Safety Precautions 5 6 Preface i aintrodictionweee ee ere 1 2 System Description and Operational Principle 1 3 Installation Requirements General eee 3 4 Installation Requirements Specie eee 4 5 Start Up Procedures 14 6 Three Modes of System OPETI On 14 7 Isolating the Major Components and Shut Down Procedures 15 8 Summer Vacation Recommendations 15 9 Maintenance and Troubleshooting 16 10 Solaray System Component Parts ea oa 17 11 Estimated Component Eire E AE A A 19 12 System Model Numbers 19 13 Collector Specifications 20 14 SunEarth Collector Warranty Statement 55 cp acoca08 22 FOR YOUR RECORDS Write the model and serial numbers here Model Number of Solar System Tank Serial Number of Solar System Tank Model Number of Collector Panel 1 Serial Number of Collector Panel 1 Model Number of Collector Panel 2 Serial Number of Collector Panel 2 Model Number of Solar System Pump Serial Number of Solar System Pump Model Number of Solar System Control Serial Number of Solar System Control You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty READ THIS MANUAL Inside you will find many helpful hints on how to use a
12. Use amp Care Manual With Installation Instructions for the Installer Pumped Solar Water Heating Systems SOLARAIDE HE This Solar Water Heating system is for the models listed below RS80 48BP RS120 64BP The purpose of this manual is twofold one to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater and two for the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also includes a parts list It is very important that all persons who are expected to install operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations If you do not understand these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional information is required refer to the section on If you need service Do not destroy this manual Please read carefully and keep in a safe place for future reference Ay recognize this symbol as an indication of Important Safety Information A caiitornia Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm
13. all a third thermometer on the solar storage tank or after the mixing valve on No 3 directly after the mixing valve above the solar the back up water heater storage tank In a two tank system you may install the third thermometer either directly above the hot outlet The circulation pump shall be the Grundfos model 17 Installing the water heater FIXED FRONT FOOT AR TELESCOPING TRUT NUT ASSEMBLY W STAND OFF TILT MOUNT UPS15 5BFC LC 115 volt The pump shall be prewired with a 6 line cord so that it can be plugged directly into the 115 volt receptacle on the side of the differential control Two way ball valves must be installed on either side of the circulating pump Nos 12 and 14 so that the pump can be isolated from the collector loop Repairs or routine system maintenance can be completed without introducing air into the system or draining the HTF The expansion tank shall have a minimum 150 PSIG working pressure and have a total volume of not less than 4 4 gallons The standard factory charge should be 40 PSIG The expansion tank shall be Rheem Ruud Therm X Guard Model RRT 12 or equal No 8 A high quality thermostatic mixing valve is a required 18 component in all OG 300 certified systems and should be plumbed in line with brass union connections for ease of future repair or replacment No 32 The specified mixing valve shall be the Heatguard model HGBASE or equal and shall have an operating range betwee
14. d 11 Not Provided 11 Drain Purge Valve Used to charge the collector loop with glycol purge air from the loop and drain the heat exchange fluid Not Provided 12 Isolation Ball Valve When closed in conjunction with No 14 will isolate the circulation pump for repair or replacement Not Provided 13 Circulating Pump Circulates the HTF through the collector loop Provided 14 Isolation Ball Valve When closed in conjunction with No 12 will isolate the circulation pump for repair or replacement Not Provided 15 Flush Valve Used to drain the solar storage tank and to flush sediment from the tank on an annual basis Not Provided 16 Tank Sensor Wired to your controller Works in conjunction with the collector sensor to turn your circulating pump on and off at preset temperature differentials Provided 17 Cold Water Dip Tube Forces incoming city cold water to the bottom of the solar storage tank to prevent mixing with the warm water at the top of the tank Provided 18 Differential Thermostat Known as the controller Automatically turns the circulating pump on and off when there is sufficient heat to be gained from the solar operation The controller also may be set to limit high temperature build up in the solar storage tank Provided 19 Heat Exchanger Transfers heat from the solar collector loop to the potable water in the solar storage tank Provided 20 Anode Rod The sacrificial anode ro
15. d is installed in your solar storage tank to prevent corrosion to the tank lining by neutralizing aggressive water action Anode rods have a finite life and require periodic replacement depending on annual tank temperatures and water quality Determine a replacement schedule with your installation contractor Provided 21 Heating Element amp Tank Thermostat The solar storage tank is equipped with an auxiliary 4500 watt 230 volt electrical heating element The thermostat controls the temperature setting of the auxiliary heating element Provided 31 22 Temperature and Pressure Relief Valve Universally required by the plumbing code on water heaters Will automatically release and dump water at either 150 PSI of pressure or 210 F in temperature Provided 23 Cold Water Supply Line Isolation Ball Valve When open allows potable water to fill the solar storage tank or back up water heater When closed isolates the solar storage tank and backup water heater from the pressurized city cold water supply line Not Provided 24 Three Way Ball Valve Used in conjunction with component No 26 to establish the proper mode of system operation Not Provided 25 Isolation Ball Valve Used in conjunction with component No 24 to completely isolate the solar storage tank for repair or replacement as necessary Not Provided 26 Three Way Ball Valve Used in conjunction with component No 24 to establish the proper mode of syste
16. d pressurize the collector loop Connect the discharge side of the pressure pump to the upper charge faucet No 9 Place the pump suction side hose in the glycol solution Close the isolation ball valve No 10 and connect a second hose to the lower charge faucet No 11 Place the other end of the hose in the empty bucket 23 TANK SENSOR Open the upper charge faucet and allow the pressure from the expansion tank to push the water in the glycol loop back to prime the pressure pump When the hose in the bucket containing the glycol mixture stops bubbling you may begin charging the collector loop with glycol With both charge faucets now open run the Flojet pressure pump until the pinkish glycol mixture begins flowing into the empty bucket Quickly switch the hose from the empty return bucket to the bucket containing the glycol mixture Continue to circulate the fluid using the pressure pump until the bubbling has stopped and the air has been purged 4 11 5 After charging the collector loop shut the lower charge faucet and let the pressure pump drive up the loop pressure to the appropriate level Generally in the range of 25 PSI To more accurately calculate the proper pressure measure the height of the solar collector above the solar storage tank and divide this number by 2 31 Then add 20 PSI to this number As a word of caution the pressure in the glycol loop should not exceed 45 PSI when the system is 24 operati
17. dle of the day If hot water usage occurs while the sun is up the fresh cold water added to the storage tank is heated more quickly When water is used late in the day or at night the fresh water entering the tank will be heated by the element so hot water is available in the morning IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING ADANGER WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater s thermostat Water temperatures above 125 F can cause severe burns or death from scalding Be sure to read and follow the warnings outlined on the label pictured below Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Temperature limiting valves are available see manual ADANGER Burns from Hot Water and Steam Use extreme care when opening relief valves charging closed loop and filling storage tank The electrical element booster thermostat has been factory set at 50 C 120 F to reduce the risk of scald injury Adjusting the thermostat to a higher setting is not recommended Hotter water increases the potential for Hot Water Scalds Time Temperature Relationship in Scalds Time To Prod
18. ed Use of uninhibited propylene glycol plain water or a concentration of these two fluids as the HTF in this system is strictly prohibited Propylene glycol can degrade over time The process of degradation is accelerated in presence of oxygen and or heat We strongly encourage you to establish a preventative maintenance schedule with your installation contractor The HTF pH level must be maintained between 8 and 10 in order to prevent glycol oxidation and corrosion of the collector piping Rheem s collector warranty specifically excludes freeze damage for any reason and absorber plate damage resulting from the oxidation of the propylene glycol HTF STAGGERED MOUNT COLLECTOR SPACING TABLE 1 LATITUDE 25 N f 30N 35 N_ OPN 45N 50N COLL TILT o o o ao y a o 5o oo 5 yo eoe DIMENSIONS A AND In order to completely protect the integrity of the solar collector and piping the system is designed to be drained manually if subject to extended periods of disuse or persistent hard freeze conditions below minus 30 Fahrenheit See Sections 8 1 and 8 2 below 3 INSTALLATION REQUIREMENTS GENERAL 3 1 The contractor shall obtain all required permits and approvals 3 2 The installation shall conform to all federal stat and local regulations codes ordinances and standards governing solar water heating system installations and the contractor
19. electric heating elements will not come on If you have a water heater timer you may preset the timer to turn the heating element on and off at specified times throughout the day if desired 6 3 100 Utility Power Leave the circuit breaker to your solar storage tank on and close the isolation ball valves in the collector loop Nos 5 and 10 In this mode of operation you must turn off the circulation pump To turn the pump off Table 5 Total Collector Loop Fluid Capacity In Gallons 1 Collector System 4 Gallon 5 Gallons 2 Collector System open the controller and change the operational setting from automatic to off Failure to turn off the pump can quickly damage the pump motor shaft bearings or impeller Two Tank System Instructions 6 4 100 Solar Operation Follow the instructions for single tank systems above You also must change the position of the three way ball valves above both the solar storage tank and the back up water heater Nos 24 and 26 Valve handle No 24 must be in the horizontal position Valve handle No 26 must be in the vertical position See Figure 19a 100 Solar Operation 6 5 Solar Preheat Follow the instructions for the single tank system for setting the thermostat and the heating elements for automatic operation The three way valve above the solar storage tank No 24 must be in the vertical position Each valve handle Nos 24 25 and 26 must be placed in the horizontal position
20. ge should read somewhere in the range of 50 75 PSI in most cases No 7 Make a final inspection of the collector plumbing connections to ensure that there are no leaks anywhere in the collector loop piping 4 11 3 After you have determined the integrity of the entire piping system turn on the circulating pump Do 21 HOT SUPPLY LINE lt TO FIXTURES 33 OPTIONAL TIME SWITCH RETURN SINGLE TANK SYSTEM SCHEMATIC this by setting the manual switch within the controller to the on position Run the pump for a full five minutes and carefully check to ensure there is proper fluid flow and that all the air has been purged from the solar collector glycol loop An inexpensive flow meter such as manufactured by Blue White Industries or Letro is recommended as an optional system 22 component A flow meter allows you to monitor and adjust the flow rate through the piping and also to visually inspect the HTF fluid quality Set the controller to the off position and proceed to the next step 5 ae HOT SUPPLY LINE TO FIXTURES afl fes 3 a h ig SRD 33 OPTIONAL TIME SWITCH DOUBLE TANK SYSTEM SCHEMATIC 4 11 4 Mix the Dowfrost HD propylene glycol and distilled water mixture in accordance with Table 4 and Table 5 in a large clean bucket You will need a second empty bucket as well The charging process also will require a low flow diaphragm pump Flojet or equal to fill an
21. he pump does run when plugged directly into the wall outlet the problem may be located in the controller or one of the 10k ohm sensors Contact your installation contractor for service 9 9 If you have a full tank of hot water before bed and the solar storage tank is cold in the morning the check valve No 4 may not be seating correctly and should be cleaned or replaced Also make sure that the circulating pump is not running after 6 00 p m If the pump is running and the control indictor light Solar 1 is on after 6 00 p m check both sensors to 29 HOT OUT VALVE POSITION DIAGRAM 2 TANK SYSTEM see that they calibrate to 10K ohm resistance at 77 F If you find a defective sensor replace it immediately Note that in a two tank system nighttime heat loss will be harder to detect especially if you are operating in the solar preheat mode Check the line thermometers No 3 in the collector loop piping to detect night thermosiphoning 9 10 If the weather is poor and the auxiliary heating element will not fire the bright red reset button on the thermostat may have to be depressed to be reset Single tank systems have one heating element and thermostat Double tank systems with conventional electric water heaters have two heating elements and thermostats see fig 17 No 29 Never remove the protective access plate on the exterior of the solar storage tank or conventional water heater without disconnecting the 230 volt power
22. ition to reducing your water heating bills it will help preserve precious natural resources by using free energy from the sun As with an electric or gas water heater your new solar water heating system operates automatically to ensure you will always have an ample supply of hot water However there are simple steps you can take to increase both its efficiency and service life This manual provides the manufacturers recommended procedures for Rheem solar water heating systems The procedures are essential for correct installation troubleshooting and maintenance Read each section of this manual thoroughly before beginning work on the system ACAUTION Changes to the design or intended use of the Rheem Solar Water Heating System will void the manufacturers warranty Installation troubleshooting and maintenance must be performed by a qualified technician This manual will help you get the most out of your solar water heating system Please read it carefully when the installation is complete and review it from time to time to refresh your memory about the service requirements and safety measures The Operation section of the manual contains important information regarding the system procedures as well as safety measures pertaining to the system It is important that you follow these guidelines to ensure safe efficient and trouble free operation While the system requires very little maintenance there will be a periodic need fo
23. lt electrical connection to the water heater or solar storage tank and the electronic time switch Optional No 33 If your solar contractor is not allowed by law to make these connections consult a licensed electrician Never activate the circuit breaker controlling the electrical heating element until the solar storage tank is completely filled with water This will prevent dry firing of the heating element The electrical heating element will be destroyed almost instantaneously if not completely submerged in water when activated Make sure the water heater circuit breaker is off until the solar storage tank is completely filled 19 1 CC CAP 1 CC COUPLING 1 X 3 4 CC 90 ELBOW OR COUPLING SUPPLY LINE 1 X 3 4 CC 90 ELBOW OR COUPLING Li z Qz gt LJ az 1 CC CAP 1 CC COUPLING fig 14 COLLECTOR PLUMBING VERTICAL MOUNT We recommend the use of a 115 volt differential control with a factory installed six foot line cord The installation requires one 115 volt outlet to be installed near the solar storage tank Plug the control into the outlet The circulation pump line cord is plugged into the receptacle on the side of the controller A 230 volt control and circulation pump may be substituted but troubleshooting the components in the future becomes more difficult 20 4 11 Charging the System AWARNING Under no circumstances can any fluid other than Dowfrost HD
24. m operation Not Provided 27 Cold Water Dip Tube See No 16 above 28 Anode Rod See No 18 above 29 Heating Elements and Thermostats See No 19 above In a two tank system the back up electric water heater has two heating elements and two thermostats Provided 30 Temperature and Pressure Relief Valve See No 22 above Provided 31 Optional Isolation Ball Valve Use with component No 26 to completely isolate the back up water heater for repair or replacement Not Provided 32 Mixing Valve Automatically blends hot water from the solar storage tank with incoming city cold water to an acceptable set point A mixing valve must be installed on every Rheem solar water heating system Provided 33 Optional Time Switch Allows you to automatically or manually turn the auxiliary heating element in the solar storage tank on and off A 32 time switch is a highly recommended option Not Provided 34 Thermal Well Not Pictured 11 Rheem SYSTEM MODEL NUMBERS RS80 48BP RS120 64BP WWW RHEEM COM PLEASE VISIT OUR WEB SITE FOR NEW PRODUCT UPDATES ANSWERS TO FREQUENTLY ASKED QUESTIONS FAQ AND USEFUL INFORMATION ABOUT SOLAR WATER HEATING SYSTEMS 33 34 35 IF YOU NEED SERVICE 1 Should you have any questions about your new water heater or if it requires adjustment repair or routine maintenance it is suggested that you first contact your installer plumbing contractor or previously agreed upon ser
25. mbing Couplings rather than unions should be used to join the collectors to avoid leaks and fluid loss Use only lead free solder Use of 50 50 lead solder is expressly prohibited Use of galvanized steel CPVC PVC or any other type of plastic pipe is prohibited 14 Piping in new solar installations can be covered with dirt grease solder flux or other impurities that over time affect the quality of the glycol HTF A thorough cleaning is required before charging the system with glycol Carefully review the cleaning procedures in Charging The System outlined below All vertical piping between the storage tank and the collector shall be supported at each story or at maximum intervals of ten feet 10 Copper plumbers tape or tube strap is required The pipe insulation may not be compressed or crimped by the strapping material The installation of all horizontal and vertical piping may not reduce the performance or rating of any structural member or fire rated assembly Adhere to all applicable local codes and ordinances BUILT UP ROOF ING OR COMPOSITION SHINGLES ON ROOFING FELT OVER DECK SHEATHING ON ROOF FRAMING SYSTEM BEAM OR RAFTER MOUNTING GROOVE 318 ST STL BOLT W LOCKWASHER amp FLATWASHER SLIDING NUT ST STL LAG BOLT LENGTH amp DIA VARY WITH INSTALLATION DRILL PILOT HOLE 3 4 OF BOLT DIA FLUSH MOUNTING 4 6 Collector Sensor Placement The collector sensor must be located on the hot wa
26. ms also can be isolated from the rest of the system Close the cold water supply line ball valve No 23 and set the three way valve handle above the conventional water heater No 26 to the vertical position Set the two way ball valve handle No 30 directly above the heater to the horizontal position fig 19a 100 SOLAR OPERATION 8 SUMMER VACATION RECOMMENDATIONS AND PROCEDURES Solar water heating systems can build up very high temperatures when there is no daily draw on the system If a short summer vacation is planned the best way to dissi pate heat in the system is to set the controller to the on position The circulating pump will run twenty four hours a day and cool off the water in the solar storage tank at night The collector radiates heat back to the atmosphere at night preventing the system from stagnating at very high temperatures This will not harm the pump or add substantially to your monthly utility bill Remember to set the control to the Automatic setting upon your return During extended summer vacations 4 weeks or more it is advisable to either cover the solar collectors with an opaque material or to manually drain the collector loop HTF Rheem recommends that you cover the collectors if practical If you choose to drain the HTF in the collector loop follow these steps 8 1 Turn the controller to the off position No 18 8 2 Connect one end of a garden hose to the purge drain valve
27. n 95 F and 140 F The mixing valve shall be set to 120 F The temperatures generated by your Rheem system will vary throughout the year In the Northern Hemisphere the water temperature will be hottest in the spring and summer months while cooler temperatures are to be expect from November through March On sunny days system temperatures may range between 110 F to 180 F depending upon the season and hot water demand The mixing valve described above blends the hot and cold water HOT WATER RETURN LINE COLLECTOR SENSOR supplies to deliver hot water to your fixtures at a safe controlled temperature AWARNING SCALDING CAN OCCUR WITHIN FIVE SECONDS WHEN WATER TEMPERATURES APPROACH 140 F THE MIXING VALVE SHOULD BE ADJUSTED BY YOUR CONTRACTOR TO PROVIDE WATER TO YOUR FIXTURES AT NO MORE THAN 120 F The 3 4 cold water supply line to the solar storage tank must be insulated with minimum 7 8 X 1 2 pipe insulation to a minimum distance of 5 behind the storage tank or to the wall if closer than 5 4 9 Tank Sensor Placement Figure 18 details the proper placement of the solar storage tank sensor Make sure the sensor is secured to the threaded stud on the storage tank with a 10 24 stainless steel nut Thoroughly weatherize the wire connections in accordance with the roof sensor detail above Replace the fiberglass insulation batting and close the access cover A properly licensed contractor must make the 230 vo
28. n of the country 1 INTRODUCTION Solar water heating systems are climate and site specific appliances Different types of solar systems are installed around the world in accordance with regional weather and water quality conditions System performance varies as a function of the household hot water load including daily showers laundry and kitchen uses average ground water and ambient air temperatures the home s roof pitch and orientation and of course the seasonal intensity of solar radiation These variables some of which change from home to home on the same neighborhood street will determine how much energy and money your Rheem system will save on an annual basis Your Rheem solar system is known as a forced circulation system because it utilizes a mechanical pump to efficiently circulate the Dow Chemical Dowfrost HD propylene glycol heat transfer fluid HTF throughout the system The HTF protects the collector piping from freezing and inhibits scaling deposits that can reduce performance in open loop systems utilizing potable water as the HTF Proper application and maintenance of the HTF can protect your Rheem solar water heating system to minus 30 Fahrenheit This manual is intended as a basic solar water heating primer Our goal is to familiarize you with the proper installation operation and maintenance of your Rheem solar system This system is required to be installed by properly licensed solar or plumbing
29. nd maintain your water heater properly Just a little preventive care on your part can save you a great deal of time and money over the life of your water heater Yov ll find many answers to common problems in the Before You Call For Service section If you review our chart of Troubleshooting Tips first you may not need to call for service at all READ THE SAFETY INFORMATION Your safety and the safety of others are very important There are many important safety messages in this manual and on your appliance Always read and obey all safety messages as an indication of Important Safety Information This symbol alerts you to potential hazards that can kill or hurt you and others This is the safety alert symbol Recognize this symbol All safety messages will follow the safety alert symbol and either the word DANGER WARNING CAUTION or NOTICE These words mean A DANGER An imminently hazardous situation that will result in death or serious injury A WARNING A potentially hazardous situation that could result in death or serious injury and or damage to property A CAUTION A potentially hazardous situation that may result in minor or moderate injury Notice Attention is called to observe a specified procedure or maintain a specific condition Introduction Thank you for purchasing a solar water heating system It is one of the most effective and trouble free systems available today In add
30. ng material There should be at least 3 of clearance between the roof surface and the bottom of the solar collectors 4 3 3 In selecting mounting hardware and fasteners it is extremely important to avoid galvanic corrosion resulting from the direct contact of incompatible metals Use of Rheem anodized aluminum Rheem mounting hardware and stainless steel lag or hanger bolts lock washers and round washers is recommended In climates subject to severe winters or high humidity use of galvanized fasteners is prohibited 4 3 4 Preserving the integrity of the roof membrane is the most important roofing consideration Ensure SOLAR COLLECTOR MOUNTING GROOVE MOUNTING SS STL SLIDING ANODIZED AL CAT AD CTD SOLAR STRU ST SI NUT UM NUTS amp WASHERS LENGTH amp DIA VARY WITH INSTALLATION DRILL PILC HOLE 3 4 BOLT LANT 2 X 12 AD FLASHING CLAY OR CONCRETE TILE ON BATTEN OVER ROOFING FELT ON ROOF DECK SHEATHING ON ROOF FRAMING SY BEAM _ AOLE 2 BOLT TILE ROOF MOUNTING that all roof penetrations required to plumb and mount the solar collector are properly flashed and sealed in accordance with standard roofing practices 4 3 5 If the region is subject to hurricane conditions additional steps may be required to secure the collector and mounting hardware to the structural members In certain areas of the country local building codes may require collector wind load testing or p
31. onal on a good sunny day Contact your solar contractor if the charged collector loop pressure exceeds this threshold Your Rheem solar water heating system must be charged and the fluid quality maintained by an experienced contractor If the system is drained during the winter or you notice a significant drop in collector loop pressure contact your installation contractor immediately for service The glycol HTF provides the freeze protection for your system and must be properly maintained An experienced contractor should periodically check the HTF fluid quality 4 11 6 Dowfrost HD HTF To ensure maximum effectiveness for corrosion protection the glycol inhibitor package is designed for a minimum 25 30 percent concentration of glycol in water Table 4 shows the concentrations of Dowfrost HD required to provide freeze and burst protection at various temperatures Use the mixture most appropriate for your climate Do not use a higher glycol to water concentration than necessary COLLECTOR SENSOR HOTTEST POINT TIMER CIRCUIT BREAKER BOX SOLAR COLLECTORS DIFFERENTIAL TEMPERATURE THERMOSTAT 120V HOUSE OPTIONAL DIGITAL CURRENT MONITOR THERMOSTAT AND RESET BUTTON 4500 WATT 240V HEATING ELEMENT STORAGE SENSOR COLDEST POINT ELECTRICAL COMPONENTS as this will adversely impact the relative heat transfer efficiency of the solution Generally for an extended margin of protection you should select a tem
32. onents If a component in the potable water side of the system may require future service or maintenance make the connections with brass unions Use only brass nipples and unions and copper and brass fittings in plumbing the solar storage tank and expansion tank The use of galvanized fittings or nipples di electric unions CPVC PVC or other plastic pipe is prohibited Hard copper connections to the city cold water supply line and the home hot water feed lines are recommended The gaskets in standard water heater flex hose connectors can become brittle and compressed over time and begin leaking on the water 16 heater If not detected in a timely manner even a small drip or leak may cause serious damage to the tank s electrical components or in extreme cases may cause the tank to leak from the outside in Tank plumbing is required to provide for the isolation of the solar storage tank from the city cold water supply line by means of an isolating ball valve No 23 Line thermometers shall be installed in the collector supply and return lines to allow for a simple diagnostic check of proper system operation On a sunny day the hot water return line should be approximately 5 12 warmer than the water in the collector supply line Compare the temperature readings in the two line thermometers No 3 SEE DETAIL D FRONT CHANNEL FOOT MOUNT ING GROOVE MOUTING CLIP TILT MOUNT In a single tank system inst
33. ot Water SCALDS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING AWARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal injury or loss of life Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater It may save you time and cost Pay particular attention to the Safety Instructions Failure to follow these warnings could result in serious bodily injury or death Should you have problems understanding the instructions in this manual or have any questions STOP and get help from a qualified service technician or the local utility A FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced anchored or strapped to resist falling or horizontal displacement due to earthquake motions For residential water heaters up to 52 gallon capacity a brochure with generic earthquake bracing instructions can be obtained from Office of the State Architect 1102 Q Street Suite 5100 Sacramento CA 95814 or you may call 916 445 8100 or ask a water heater dealer However applicable local codes shall govern installation For residential water heaters of a capacity greater than 52 gallons consult the local building jurisdiction for acceptable bracing procedures SAFETY PRECAUTIONS Have the
34. perature that is at least 5 F lower than the expected lowest ambient temperature These figures are examples only and should not be regarded as specifications As conditions are not within our control neither Rheem nor Dow Chemical guarantees that freeze damage may not occur at temperatures other than shown Water used to dilute the HTF must meet certain minimum standards for purity Impurities in the dilution water can increase metal corrosion reduce the effectiveness of corrosion inhibitors increase inhibitor 25 depletion rate and cause the formation of scale and other deposits on the heat exchanger s internal heat transfer surfaces Distilled or deionized water is required The HTF pH level must be maintained between 8 and 10 to minimize corrosion and glycol oxidation in the piping system 5 SYSTEM START UP PROCEDURES Throughout the installation procedures outlined in Section 4 above emphasis has been placed on the correct procedures for plumbing and wiring the components checking for plumbing leaks pressurizing the collector glycol loop and eliminating any trapped air that can impact fluid quality and pump performance Having completed these tasks it is time to start up your Rheem solar water heating system When the glycol loop has been fully charged and the pressure is around 25 psi check the pressure gauge No 7 set the differential controller to the Automatic setting This will activate your ci
35. r solar storage tank No 20 Typically constructed from magnesium anode rods are installed in glass lined water heaters and storage tanks to inhibit corrosion As the name implies the sacrificial anode rod is fig 19b SOLAR PREHEAT consumed so that the tank lining is not At a certain point in the process the anode rod is no longer completely effective and the corrosive processes begin to eat away at the tank s glass lining In time the solar storage tank like any other gas or electric water heater will begin to leak The process is not reversible and the tank must be replaced System temperatures and water quality affect the rate at which the anode rod is consumed In general the higher the average system temperature the faster the rate of corrosion By changing the anode rod after the fifth year of system operation and every three to five years thereafter it is possible to extend the life of the solar storage tank Periodic replacement of the anode rod in your solar storage tank can significantly extend the tank life 9 3 The solar storage tank also should be flushed annually to minimize sediment build up on the bottom of the tank If you live in an area with high mineral content in your water flush the tank on a semi annual basis Disconnect the power to the solar tank at the circuit breaker or time switch if present before flushing Turn the controller to the off position Open the flush valve on the bot
36. r some upkeep The Maintenance section outlines those requirements for service which you may do yourself as well as those procedures best performed by a qualified service technician The Troubleshooting section contains steps you can take if the system is not performing as it should The solar energy system described by this manual when properly installed and maintained meets the minimum standards established by the Solar Rating and Certification Corporation SRCC This certification does not imply endorsement or warranty of this product by the SRCC The solar energy system described by this manual when properly installed and maintained meets the minimum standards established by the Florida Solar Energy Center in accordance with Section 377 705 Florida Statutes This certification does not imply endorsement or warranty of this product by the Florida Solar Energy Center or the state of Florida The components of the system include a water storage tank solar collector panels expansion tank pump valves and fittings In locations which are subject to temperatures below 41 F a mixture of heat transfer fluid and water circulates through the solar collector panels This fluid is heated by the sun then circulated through a heat exchange heating the potable drinking water inside the storage tank The heat transfer fluid is a non toxic food grade liquid which provides freeze protection for the closed loop heat transfer loop
37. rculating pump The controller allows you to set the on differential Turn the red rotary switch inside the control housing to 12 Adjust the valve settings in accordance with Section 6 below Table 4 Percent volume Glycol Concentration Required Temperature F For Freeze Protection For Burst Protection 6 THREE MODES OF SYSTEM OPERATION Both single and double tank Rheem systems are designed to accommodate three separate modes of operation Your solar water heating system can 1 provide 100 solar operation during good weather or 2 serve as a preheater to your electric water heater adding solar energy when and as available or 3 completely bypass the solar collector loop and solar storage tank and run 100 on utility power during inclement weather Single Tank Operating Instructions 6 1 100 Solar Operation Turn off the circuit breaker to your solar storage tank If a water heater time switch has been installed set the switch to the off position If you have a mechanical timer remove the trippers from the face of the switch 6 2 Solar Preheat Leave the circuit breaker to your solar storage tank on and set the tank thermostat to the lowest acceptable temperature setting The electric resistance heating elements will come on only when the tank temperature falls below the thermostatic set point If the solar heated water entering the tank is warmer than the thermostatic set point the
38. rescribe specific mounting procedures Consult your local building department 4 4 Collector Loop Pipe Insulation The collector loop cold supply and hot return lines must be well insulated with a high quality flexible closed cell insulation to minimize heat loss The wall thickness of the pipe insulation should not be less than 3 4 A 1 wall thickness is required in all areas prone to annual hard freeze conditions When it comes to pipe insulation the rule is simple thicker is better Use 3 4 Armaflex or similar flexible elastomeric closed cell thermal insulation To the extent possible slide the insulation material over the pipe without cutting or taping All butt joints must be sealed with contact adhesive The use of rigid polyethylene pipe insulation is prohibited The temperatures generated by your collector in the summer months or under stagnation conditions can melt this type of material 13 Installing the water heater STAINLESS SLIDING NU ANODIZED ALUM MOUNT ING CLIP TILE ROOF MOUNTING Any above ground exterior pipe insulation is subject to UV degradation and must be wrapped with foil tape or painted with two coats of high quality water based acrylic resin coating as supplied by the insulation manufacturer Use 3 4 Armaflex or similar flexible elastomeric closed cell thermal insulation 4 5 Collector Plumbing Rheem requires the use of all copper and brass fittings in the collector loop plu
39. t least 10 Never mount the collector directly or parallel to a flat roof surface Use Solar Strut tilt mount kits to rack the collectors to the proper angle The collector should be mounted as close to the storage tank as possible to minimize heat loss in the piping runs If the home has attic access mounting the collectors near the roof peak provides for additional 11 Installing the water heater MOU NTING clip ANODIZED ALUM SOLAR STRUT ST STL NUTS amp WASHERS BOLT DIA SOLAR COLLECTOR SIDE VIEW MOUNTING GROOVE MOUNTING CLIP 7 ROOF ING SEALANT j a y 2 n LEAD FLASH CEDAR SHAKE OR SHINGLE OR ASPHALT SHINGLES ON ROOF FELT OVER ROOF DECK SHEATHING ON ROOF FRAMING SYSTEM BEAM OR RAFTER SHINGLE ROOF MOUNTING attic workspace The solar collector should be mounted on the roof in accordance with these general principles 4 3 1 The most important structural consideration is to securely anchor the solar collector and the Rheem mounting hardware to the structural members of the roof with stainless steel hanger or lag bolts The solar collector must be attached to the mounting hardware as detailed in Figures 5 12 Note The drawings in this manual detail mounting hardware for the Rheem series collector 4 3 2 The collector must be raised from the roof surface to allow for rainwater and debris to pass under 12 the collectors and for proper ventilation of the roofi
40. ter return line as close to the collector as possible Sensors are typically accurate to 1 2 F if properly installed and weatherized To maximize sensor accuracy attach the flanged portion of the sensor to the Rheem collector header pipe with a stainless steel hose clamp Wire nuts used to connect the sensor and low voltage wiring shall be all plastic sealed with silicone and thoroughly wrapped in electrician s tape The sensor bundle must be placed under the rubber pipe insulation covering the collector header Thoroughly wrap and weatherize the insulation with electrician s tape or insulation tape as provided by the manufacturer Rubatex Insul Tape or equal See Figure 13 for collector sensor installation detail 4 7 Low Voltage Wiring The low voltage wiring used to connect the sensors to the controller should be a minimum18 AWG The wiring should be bare or tinned copper two conductor PVC insulated with a PVC UV rated gray jacket suitable for exterior use Use Eastman Wire amp Cable No 5704 Belden Wire and Cable No 8461 or equal 4 8 Installing the Solar Storage Tank and Expansion Tank In plumbing the solar storage tank and expansion tank make sure that all the components are accessible and 15 Installing the water heater SEE DETAIL A FLUSH MOUNTING easy to reach Provide for clear access to the storage tank pump expansion tank mixing valve time clock optional not provided and other key comp
41. tom of the storage tank No 15 and drain a sufficient volume of water to eliminate the sediment After the procedure is complete make sure the tank is completely full of water before restoring power to the thermostat and heating element Turn the controller to the on position 9 4 If you live in a dusty climate it is a good idea to wash off the dirt that settles on the collector glass once a month Clean glass allows the collector to fig 19 100 UTILITY POWER maintain a high level of thermal performance 9 5 Check the exterior pipe insulation annually and patch or repair any exposed surfaces or degraded areas Repaint as necessary 9 6 In the unusual instance of collector glass breakage the glass should be replaced immediately This will reduce the likelihood of water accumulating inside the collector and deteriorating the insulation Contact your installation contractor 9 7 If you detect a glycol or water leak or the glycol loop pressure drops unexpectedly contact your installation contractor immediately to diagnose the problem and recharge the system 9 8 If it s been a sunny day and you don t have hot water first make sure that the controller is set in the automatic position If the controller is properly set and the pump has not been running unplug the line cord from the controller receptacle and plug the pump directly into a nearby 115 volt outlet If the pump does not run it may need to be replaced If t
42. tures In two tank systems the thermometer will read the finished solar tank temperature Provided 4 Check Valve This valve is installed to stop or minimize convective evening heat loss in the system The heat in the solar storage tank will rise through the collector loop piping in the evening into the much cooler solar collector and dissipate heat unless prevented from doing so by a check valve Check valves are also sometimes referred to as one way valves Provided 5 Isolation Ball Valve Used in conjunction with component No 10 to isolate the solar collector loop from the solar storage tank Not Provided 6 Pressure Relief Valve Will release glycol loop HTF at 150 PSI If this valve opens and HTF fluid is expelled contact your contractor immediately This valve also can be opened to drain the HTF from the charged glycol loop for replacement Provided 7 Pressure Gauge Indicates the pressure in the charged glycol collector loop Provided 8 Expansion Tank Pre charged with air to allow for the expansion and contraction of the glycol HTF as it heats and cools Not Provided 9 Charge Valve Used to charge the collector loop with glycol and also to eliminate air from the system Not Provided 10 Isolation Ball Valve Used in conjunction with component No 5 to isolate the solar collector loop from the solar storage tank Also used with the charge valves to fill and pressurize the collector glycol loop Nos 9 an
43. uce a Serious Burn D 120 F More than 5 minutes 125 F 1 to 2 minutes 130 F About 30 seconds 135 F About 10 seconds 140 F Less than 5 seconds 145 F Less than 3 seconds 150 F About 1 seconds 155 F About 1 second Table courtesy of Shriners Burn Institute The chart shown above may be used as a guide in determining the proper water temperature for your home ADANGER Households with small children disabled or elderly persons may require a 120 F or lower thermostat setting to prevent contact with HOT water NOTICE Mixing valves should be installed to reduce the point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed installer or the local plumbing authority for further information The temperature of the water in the water heater can be regu lated by setting the temperature dial of the adjustable surface mounted thermostat located behind the jacket access panel Reset button Thermostat dial pointer TURN OFF POWER BEFORE SERVICING Thermostat _LIl_ protective cover This thermostat controls the water heater s heating ele ment only A separate ther mostat should be utilized in monitoring the temperature from the collector To comply with safety reg ulations the thermostat is factory set at 120 F or less where local codes require ADANGER Hotter water increases the potential for H
44. vice agency In the event the firm has moved or is unavailable refer to the telephone directory commercial listings or local utility for qualified service assistance 2 Should your problem not be solved to your complete satisfaction you should then contact the Manufacturer s National Service Department at the following address 1241 Carwood Court Montgomery Alabama 36117 Phone 1 800 432 8373 When contacting the manufacturer the following information will be requested a Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater b Address where the water heater is located and physical location c Name and address of installer and any service agency who performed service on the water heater d Date of original installation and dates any service work was performed e Details of the problems as you can best describe them f List of people with dates who have been contacted regarding your problem 36
Download Pdf Manuals
Related Search
Related Contents
Twin Pack Reusable Silica Dehumidification Kit MINI-MIXER - Westim SpA VersaMax Ethernet NIU, IC200EBI001-GG and IC200EBI001 1 Questions fréquentes Anleitung BG_BC_41_43_SPK2:_ Machine Mini Jet Pont Manual - Doug Fleenor Design サーモスタット付シャワーバス水栓 Optoma X304M data projector Copyright © All rights reserved.