ResMed S8 Series II Respiratory Product User Manual

image

Contents

1. Right a Performs the function indicated by the guiding text displayed above it on the LCD screen eg exit The keypad and LCD are equipped with backlights that come on when the device is powered The LCD backlight turns off after two minutes of inactivity and comes back on when you press a key The keypad backlight is always on while the S8 Series II is on Selecting the Mask Type To ensure your device functions as intended with your selected mask you need to select the mask type that you are using 1 With the RAMP or SETTLING screen displayed press In CPAP mode the standby screen displays RAMP In AutoSet mode S8 AutoSet Spirit II only the standby screen displays SETTLING Press until MASK is displayed Press g to change the setting 4 5 Press or until you see the setting that you require Press GS to apply Using the Mask fitting Feature You can use the S8 Series I mask fitting feature to help you fit your mask properly This feature delivers air pressure for a three minute period prior to starting treatment during which you can check and adjust your mask fit to minimise leaks Note Make sure that the mask setting on the MASK screen is the same as the mask you are using 1 2 Fit your mask as described in the mask user instructions With the RAMP or SETTLING screens displayed hold down 7a for at least three seconds until air pressure delivery starts Your device will ramp to the mask fit
2. 000 000 0 000 14 General Warnings and Cautions 15 Limited Warranty 0 00 0 00 0 ene 17 Introduction S8 AutoSet Spirit Il The S8 AutoSet Spirit II self adjusting sleep apnea system is indicated for the treatment of obstructive sleep apnoea OSA in adult patients The S8 AutoSet Spirit II self adjusting sleep apnoea system has two treatment modes AutoSet and fixed pressure CPAP The S8 AutoSet Spirit II system is intended for home and hospital use S8 AutoScore Il The S8 AutoScore continuous positive airway pressure CPAP system is indicated for the treatment of obstructive sleep apnoea OSA in adult patients The S8 AutoScore Il CPAP system is intended for home and hospital use Contraindications Your S8 Series II is not a life support device and may stop operating during power failure or certain fault conditions It should not be used by patients who are dependent on continuous therapy Positive airway pressure therapy may be contraindicated in some patients with the following pre existing conditions e severe bullous lung disease pneumothorax e pathologically low blood pressure dehydration e cerebrospinal fluid leak recent cranial surgery or trauma Adverse Effects Patients should report unusual chest pain severe headache or increased breathlessness to their prescribing physician An acute upper respiratory tract infection may require temporary discontinuation of trea
3. data error on the Data Contact your clinician immediately Card The following message is NOT displayed on the LCD after you try to update the settings using the Data Card Settings Success Remove Card The settings were not updated Contact your clinician immediately Troubleshooting 13 Problem Possible Cause Solution The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Settings Invalid Remove Card The identification details on the Data Card do not match the Contact your clinician immediately identification details on your device Technical Specifications Operating pressure range Dimensions H x W x D Weight Operating Temperature Power Supply Operating Humidity Storage and Transport Temperature Storage and Transport Humidity Operating Altitude Electromagnetic Compatibility Air Filter Air Tubing Air Outlet IEC 60601 1 Classifications Housing Construction 4 to 20 cm H20 112 mm x 164 mm x 145 mm 1 4 kg 5 C to 36 C e Input range for S8 Series II with H4i 100 240V 50 60Hz 110V 400Hz 2 5A lt 140VA 110W maximum power consumption Instantaneous peak power consumption lt 340VA e Refer to the DC 12 converter instructions for DC ratings Only use the ResMed DC 12 converter for DC input e Typical power consumption at 20 cm H20 is 39VA or 20 7W 10 95 non condensing 20 C to 60 C 10 95 non condensing Sea
4. device is powered and To stop treatment at any time remove your mask and press Co Ds If your clinician has enabled SmartStart simply remove your mask and treatment will end Changing the Settings on your S8 Il Device You can change settings such as Ramp Time EPR Level on S8 II devices by using the keypad and LCD When the device is in standby mode you can display a series of screens a menu on the LCD screen in order to view and change the settings for a particular function The Standard Menu Your clinician will have enabled a standard menu on your S8 Series device The figure below shows the standard menu in each mode To enter the standard menu from the standby RAMP or SETTLING screen press CPAP WELCOME gt gt gt gt gt gt RAMP 10min menu t EPR LEVEL 1 change exit USED HRS 08000 exit USAGE 1000 1068 exit MASK ULTRA change t exit SW SX4800100 t exit AUTOSET SETTLING 10min t EPR LEVEL 1 change exit USED HRS 08000 t exit USAGE 1000 1068 t exit MASK ULTRA change t exit SW SX4800100 t exit Only displayed if access set by clinician Note The AutoSet menu is available on the S8 AutoSet Spirit only The Detailed Menu Your clinician may have enabled a detailed menu on your S8 Series I device The figure below shows the detailed menu in each mode To enter the
5. pressure and will remain at this pressure for three minutes The following displays on the LCD screen indicating that the mask fitting feature is operating where is an excellent fit is a very good fit is a good fit while and each require you to adjust your mask MASK FIT Pen excelnt Adjust your mask mask cushion and headgear until you have a secure and comfortable fit After three minutes the pressure reverts to the set pressure and treatment will begin If you do not wish to wait three minutes hold down Ja for at least three seconds to start treatment immediately If you press CO Ja for less than three seconds the unit will return to standby mode the RAMP or SETTLING screen Starting Treatment 1 Make sure the power is on The product name is displayed briefly on the screen then the standby screen displays RAMP or SETTLING The key and LCD backlights also turn on Lie down and arrange the air tubing so that it is free to move if you turn in your sleep CAUTION Do not leave long lengths of air tubing around the top of your bed They could twist around your head or neck while you are sleeping Alter the ramp or settling time if required Using the S8 Series II 5 4 To start treatment press CO Js 5 Fit your mask as described in the mask user instructions WARNING operating properly Stopping Treatment J A mask should not be used unless the S8 Series II
6. types of PAP machines e Oxygen supports combustion Oxygen should not be used while you are smoking or in the presence of an open flame Always ensure airflow is being generated by the device before the oxygen supply is turned on e Always turn the oxygen supply off before stopping the airflow from the device Note At a fixed rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on where the oxygen is introduced the pressure settings patient breathing pattern mask selection and leak rate Do not use the S8 Series II if there are obvious external defects or unexplained changes in performance Do not open the S8 Series I case There are no user serviceable parts inside Repairs and internal servicing should only be performed by an authorised service agent Explosion hazard do not use in the vicinity of flammable anesthetics CAUTIONS At low pressures the flow through the exhalation ports of your mask may not clear all exhaled gas from the tubing Some rebreathing may occur The airflow for breathing produced by this device can be as much as 11 F 6 C higher than the temperature of the room Caution should be exercised if the room temperature is warmer than 90 F 32 C When AC mains power 100 240V AC is not available always use a ResMed DC 12 converter The DC 12 converter is available as an optional accessory It is not supplied with all models Note The above are general w
7. 27 NZ 406928 US D544598 US D553228 S8 S8 AutoSet S8 Elite and SmartS art are trad 2008 ResMed Ltd 338575 2 08 10 U 302181 AU 302182 AU 302183 AU 302184 AU 302185 AU 302186 CN 200430121212 2 CN 30121214 1 CN 200430121215 6 CN 200430121216 0 CN 200430121217 5 EU 269436 EU 815071 HK US D557406 US D557407 US 0560795 US D561891 US D565160 Others pending lemarks of ResMed Ltd and AutoSet and HumidAire are registered in U S Patent and Trademark Office Contents IntrOGUCTION coatet 5263 56 i a Bede bn S Pie hind PIRES I 1 Contraindications 1 Adverse Effects 1 Parts of the S8 Series Il system 0000005 2 Masks 2 Humidifiers 2 ResScan Data Card 2 Using the S8 Series Il 0 000 0 00000 eee ee 3 Setting Up 3 How to Use the Control Panel 4 Selecting the Mask Type 4 Using the Mask fitting Feature 5 Starting Treatment 5 Stopping Treatment 6 Changing the Settings on your S8 II Device 6 The Standard Menu 6 The Detailed Menu 7 Messages on the S8 Series II LCD 8 Using the Data Card to Collect Data 8 Copying Data onto the Data Card 8 Cleaning and Maintenance 00 000005 9 Daily 9 Weekly 9 Monthly 9 Replacing the Air Filter 10 Servicing 10 Frequently Asked Questions 002 005 11 Troubleshooting 0 00 000 cece 12 Technical Specifications
8. Air tubing may be kinked or punctured Straighten or replace Displays error message SYSTEM ERRxxxx Call Service or Exxxx where xxxx defines an error Component failure Record error number and call service Displays error message Check tube Key if done Air tubing is loose or blocked Check that the air tubing is connected securely to your mask and the air outlet to the front of the S8 Series II When you have checked the air tubing press the Start Stop key to restart the device If this does not clear the message disconnect the power cord and then reconnect it to restart the device The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Card Error Remove Card Data Card is not inserted correctly Check that the Data Card is inserted into the Data Card module with the arrow facing up while the S8 Series II is switched on and not delivering therapy standby mode The Data Card is only partly Ensure that the Data Card is inserted into the Data Card inserted slot as far as it will go You may have removed the Data Reinsert the Data Card and wait for the Settings Card before settings were copied to Success Remove Card message to appear on the the S8 Il LCD The card is not a ResScan Data Only use a ResScan Data Card Card The following message is displayed on the LCD after you try to update settings or copy data to the Data Card Settings Error Remove Card There is a
9. Card Inserted Please Wait message is displayed on the S8 Series LCD while data is being copied Copying takes approximately five seconds The Copy Complete Remove Card message is displayed on the LCD when copying has finished 3 4 5 Remove the Data Card by gripping the end of the Data Card and pulling it out Store the Data Card in its protective folder when not in use Return the card in its protective folder to your clinician using a postal envelope Updating Settings on your S8 device If your clinician has provided a Data Card with new device settings 1 U N With the device in standby Ramp or Settling mode insert the Data Card into the Data Card slot Updating will start automatically The Card Inserted Please Wait message is displayed on the LCD while updating is in progress Updating takes approximately five seconds The Settings Success Remove Card message is displayed on the LCD if the settings were updated successfully Note This message only appears once If you re insert the Data Card after you have updated your settings this message is not displayed Remove the Data Card from the S8 Series II Store the Data Card in its protective folder when not in use WARNING If your clinician has told you to use this Data Card to update the settings on your device and the Settings Success message does not appear contact your clinician immediately Cleaning and Maintenance Daily Disco
10. RESMED S8 Series Il S8 AutoSet Spirit Il S8 AutoScore Il POSITIVE AIRWAY PRESSURE DEVICES User Guide English ResMed Ltd Manufacturer 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp US Designated Agent 14040 Danielson Street Poway CA 92064 6857 USA ResMed UK Ltd EU Authorized Representative 96 Milton Park Abingdon Oxfordshire 0X14 4RY UK ResMed Offices Australia Austria Belgium Brazil China Finland France Germany Greece Hong Kong India Ireland Italy Japan Malaysia Mexico Netherlands New Zealand Norway Portugal Singapore South Africa Spain Sweden Switzerland UK USA see www resmed com for contact details Protected by patents AU 691200 AU 697652 AU 709279 AU 724589 AU 730844 AU 736723 AU 750095 AU 750761 AU 764761 AU 779327 AU 2002231456 CN 02804930 6 EP 065 3778797 NZ 504595 US 5199424 U S 5245995 1971 EP 0661071 EP 0920845 EP 0934723 EP 1028769 EP 1126893 EP 1502618 EP 1144036 JP 3580776 JP US 5522382 US 5704345 US 6029665 US 6138675 US 6240921 US 6363933 US 6367474 US 6425395 US 6502572 US 6591834 US 6705315 US 6745768 US 6817361 US 6988498 US 7040317 US 7100608 Other patents pending Protected by design registrations AU 302180 Al 200430121213 7 CN 200430121211 8 CN 2004 0412901 9 JP 1257662 JP 1257663 JP 1266956 JP 1266957 JP 1267270 JP 1267271 NZ 405614 NZ 406923 NZ 406924 NZ 406925 NZ 406926 NZ 4069
11. arnings and cautions Specific warnings cautions and notes appear with the relevant instructions in the manual Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period specified below from the date of purchase by the initial consumer This warranty is not transferable Product Warranty Period ResMed humidifiers ResControl ResLink ResTraxx 1 Year ResMed flow generators 2 Years Accessories mask systems including mask frame cushion 90 Days headgear and tubing Excludes single use devices Note Some models are not available in all regions f the product fails under conditions of normal use ResMed will repair or replace at its option the defective product or any of its components This Limited Warranty does not cover a any damage caused as a result of improper use abuse modification or alteration of the product b repairs carried out by any service organisation that has not been expressly authorised by ResMed to perform such repairs c any damage or contamination due to cigarette pipe cigar or other smoke d any damage caused by water being spilled on or into a flow generator Warranty is void on product sold or resold outside the region of original purchase Warranty claims on defective product must be made by the initial consumer at the point of purchase This warranty is in lieu of all other express or implie
12. d warranties including any implied warranty of merchantability or fitness for a particular purpose Some regions or states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale installation or use of any ResMed product Some regions or states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from region to region For further information on your warranty rights contact your local ResMed dealer or ResMed office RO01 307 2 05 06 Limited Warranty Limited Warranty 19 20
13. detailed menu from the standby RAMP or SETTLING screen press GI RAMP 10min men esi WI CPAP AUTOSET SETTINGS enter 4 exit ra EPR LEVEL 1 EPR LEVEL 1 change 4 exit change exit MASK ULTRA MASK ULTRA change t exit change t exit TUBE LENGTH 2m TUBE LENGTH 2m change f exit change exit HUMID NONE HUMID NONE change t exit change exit SMARTSTART ON SMARTSTART ON change exit J change f exit J LEAK ALERT OFF LEAK ALERT OFF change f exit J change f exit J RESULTS enter f exit USED HRS 08000 exit USAGE 1000 1068 t exit SMART DATA enter f exit OPTIONS enter f exit SMART DATA AUTO APPEAR OFF enter exit change cancel LANG ENGLISH change f exit SERVICING enter f exit SN 12345678912 4 exit PCB 123456789123 4567 exit SW SX4800100 t exit Only displayed if access set by clinician Note The AutoSet menu is available on the S8 AutoSet Spirit II only Changing the Settings on your S8 II Device 7 Messages on the S8 Series II LCD Your clinician may have set your S8 Series device to remind you about important events such as when to replace your mask when to insert your Data Card if your device is Data Card enabled and so on The reminder message is displayed on the LCD and is visible if the device is not delivering therapy The backlight on the LCD flashes when a message is displayed Your clinician can se
14. e or holes associated with the mask should never be blocked Explanation The S8 Series II is intended to be used with special masks or connectors which have vent holes to allow continuous flow of air out of the mask When the device is turned on and functioning properly new air from the device flushes the exhaled air out through the mask vent holes However when the device is not operating insufficient fresh air will be provided through the mask and the exhaled air may be rebreathed Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation This applies to most models of PAP devices e Inthe event of power failure or machine malfunction remove the mask The S8 Series II can be set to deliver pressures up to 20 cm H320 In the unlikely event of certain fault conditions pressures up to 30 cm H320 are possible Ports may be incorporated into the mask or in connectors that are near the mask General Warnings and Cautions 15 16 If oxygen is used with this device the oxygen flow must be turned off when the device is not operating If the oxygen has been left on turn off the device then wait 30 minutes before turning on the device again Explanation When the PAP device is not in operation and the oxygen flow is left on oxygen delivered into the air delivery tubing may accumulate within the PAP machine enclosure and create a risk of fire This applies to most
15. ipment This device should be disposed of separately not as unsorted municipal waste To dispose of your device you should use appropriate collection reuse and recycling systems available in your region The use of these collection reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment If you need information on these disposal systems please contact your local waste administration The crossed bin symbol invites you to use these disposal systems If you require information on collection and disposal of your ResMed device please contact your ResMed office local distributor or go to www resmed com environment General Warnings and Cautions WARNINGS J Read the entire guide before using the S8 Series Il e Advice contained in this guide should not supersede instructions given by the prescribing physician e A patient should not connect a device to the data communication port unless instructed to do so by their health care provider or physician Only ResMed products are designed to be connected to the data communication port Connecting other devices could result in injury or damage to the S8 Series II device e The S8 Series II should be used with masks and connectors recommended by ResMed or by a physician or respiratory therapist A mask should not be used unless the S8 Series device is turned on and operating properly The vent hol
16. level to 2 591 m Product complies with all applicable electromagnetic compatibility requirements EMC according to IEC60601 1 2 for residential commercial and light industry environments The electromagnetic compatibility tables for these ResMed devices can be found on www resmed com on the Products page under Service amp Support Click on the PDF file for your device Two layered powder bonded polyester non woven fiber Flexible plastic 2 m The 22 mm conical outlet complies with EN 1281 1 Class II double insulation Type CF Flame retardant engineering thermoplastic DECLARED DUAL NUMBER NOISE EMISSION VALUES in accordance with ISO 4871 Sound Pressure Level Sound Power Level Supplemental Oxygen 24 dBA with uncertainty of 2 dBA as measured according to SO 17510 1 2002 26 dBA with uncertainty of 2 dBA as measured according to SO 17510 1 2007 34 dBA with uncertainty of 2 dBA as measured according to SO 17510 1 2007 Recommended maximum supplemental oxygen flow 4 L min The manufacturer reserves the right to change these specifications without notice Symbols which appear on the device A Attention consult accompanying documents Cli Follow instructions for use 4 Drip proof y Type CF equipment 4 Dangerous voltage o Class equipment Oo Start Stop taal Manufacturer DA Environmental information WEEE 2002 96 EC is a European Directive that requires the proper disposal of electrical and electronic equ
17. lve this discomfort Contact your clinician for advice My nose is irritated during treatment what can I do You may experience sneezing and or a runny or blocked nose during the first few weeks of treatment In many cases nasal irritation can be resolved with a humidifier Consult your clinician or equipment supplier for advice Can I travel with the S8 Series II Your S8 Series II has an internal power supply that enables it to operate in other countries It will operate on power supplies of 100 240V and 50 60Hz No special adjustment is necessary but you will require an approved power cord for the region in which you are using the device Your S8 Series II device automatically adjusts to changes in altitude up to 2 591 m Frequently Asked Questions 11 Please consult the medical services department of your carrier if you intend to use your S8 Series II on an aircraft The S8 Series II complies with US FCC Part 15 Class B requirements Note Do not use your S8 Series II while the aircraft is taking off or landing Can I use my S8 Series Il if mains AC power is not available A DC 12 converter is available to connect the S8 Series II to a 12V or 24V DC power source Contact your clinician for details Troubleshooting If there is a problem try the following suggestions If the problem cannot be solved contact your equipment supplier or ResMed Do not attempt to open the device Problem Possible Cause Solution No display Po
18. nnect the air tubing and hang it in a clean dry place until next use Weekly 1 Remove the air tubing and wash it in warm water using mild detergent 2 Rinse thoroughly hang and allow to dry 3 Before next use reassemble the mask and headgear 4 Reconnect the air tubing Monthly 1 Clean the exterior of the S8 Series II with a damp cloth and mild liquid soap 2 Check the air filter for holes and blockage by dirt Cleaning and Maintenance 9 WARNING Beware of electric shock Do not immerse the device or power cord in water Always unplug the device before cleaning and make sure it is dry before reconnecting CAUTION Do not hang the air tubing in direct sunlight as it may harden over time and eventually crack e Do not use bleach chlorine alcohol or aromatic based solutions moisturising or antibacterial soaps or scented oils to clean the air tubing or the device These solutions may cause hardening and reduce the life of the product Replacing the Air Filter Replace the air filter every six months or more often if necessary 1 Remove the air filter cover at the back of the device Air filter cover 2 Remove and discard the old air filter 3 Insert a new filter with the blue tinted side facing out from the device 4 Replace the air filter cover CAUTION Do not wash the air filter The air filter is not washable or reusable e The air filter cover protects the device in the event of accidental li
19. nsation What do I do when I want to get up in the night If you need to get up during the night remove your mask and stop therapy Always remember to restart therapy and put your mask on when you return to bed What do do if I feel air leaking out of the mask The S8 Series I delivers the most effective treatment when the mask is well fitted and comfortable Treatment can be affected by leaks so it is important to eliminate any leaks that may arise For example try repositioning the mask and adjusting the straps If you are using a nasal mask try to keep your mouth closed during treatment Air leaks from your mouth can decrease the effectiveness of your treatment If mouth leaks are a problem a full face mask or chin strap may help Contact your clinician or equipment supplier for further details If you are using a full face mask and you have problems trying to get a comfortable mask fit contact your clinician or equipment supplier You may benefit from a different size or style of mask Anything special should do before putting the mask on Before wearing your mask wash your face to remove excess facial oils This will allow a better fit and prolong the life of the mask cushion Do not use moisturiser when wearing a mask My mouth feels dry during treatment what can I do You may experience dryness of the nose mouth and or throat during the course of treatment especially during winter In many cases a humidifier may reso
20. quid spillage onto the device Ensure the air filter and air filter cover are fitted at all times Servicing This device is intended to provide safe and reliable operation when operated and maintained in accordance with the instructions provided by ResMed To ensure that your device continues to provide optimum performance it is recommended that this product S8 AutoSet Spirit Il S8 AutoScore II be inspected by an authorised ResMed Service Centre five years from the date of purchase Applicable ResMed warranty details are provided with the device at the time of original supply Of course as with all electrical devices if any irregularity becomes apparent you should exercise caution and have the device inspected by an authorised ResMed service centre If you feel that your device is not performing properly see Troubleshooting on page 12 CAUTION J Do not attempt to open the S8 Series II case There are no user serviceable parts inside Inspection and repair should only be performed by an authorised agent Under no circumstances should you attempt to service or repair the S8 Series II yourself Frequently Asked Questions How will it feel when am breathing with the S8 Series II When you first use your S8 Series device you may feel uncomfortable breathing against the airflow This is normal You will continue to breathe normally while you sleep The EPR setting may also improve comfort Take time to adjust to this new se
21. sk see your mask manual WARNING c Make sure the power cord and plug are in good condition and the equipment is not damaged Only ResMed air tubing should be used with the device A different type of air tubing may alter the pressure you actually receive reducing the effectiveness of your treatment Blocking the hose and or air inlet of the device while in operation could lead to overheating of the device AUTION Be careful not to place the device where it can be bumped or where someone is likely to trip over the power cord If you put the device on the floor make sure the area is free from dust and clear of bedding clothes or other objects that could block the air inlet Make sure the area around the device is dry and clean Using the S8 Series II 3 How to Use the Control Panel LCD screen Keypad Start Stop key The control panel of the S8 Series II includes an LCD screen which displays the menus and treatment screens as well as a keypad for navigating through the menus and delivering treatment The S8 Series II keypad has the following keys Key Function Start Stop Cos Starts or stops treatment Allows you to increase settings options and scroll through U CA P the S8 Series II menu Allows you to decrease settings options and scroll through Down the S8 Series II menu Left Performs the function indicated by the guiding text displayed above it on the LCD screen eg change
22. t any of the following reminders on your LCD Message Description Action INSERT May appear if your device is Insert your Data Card and follow any CARD Data Card enabled instructions that your clinician has given you When you have done this the message will disappear from the LCD Pressing CG Ok will also remove the message REPLACE May appear when your mask Press GC Ok to remove the message MASK is due for replacement from your LCD and replace your mask with a new one CALL May appear as a reminder to Press GI Ok to remove the message PROVIDER contact your clinician eg to from your LCD and contact your clinician discuss how your therapy is going REPLACE May appear as a reminder to Press CG Ok to remove the message FILTER replace the air filter on your from your LCD and replace the air filter device SERVICE May appear as a reminder to Press gj Ok to remove the message DUE return your device for service from your LCD and contact your clinician Using the Data Card to Collect Data If your clinician needs to review your treatment they will ask you to use the Data Card to copy data from your S8 Series Il and to return the card to them Copying Data onto the Data Card 1 Switch on the S8 Series II and wait until you see the standby Ramp or Settling screen 2 Hold the Data Card with the arrow facing up and insert it into the Data Card slot until it stops Data copying starts automatically The
23. tment The following side effects may arise during the course of therapy with the CPAP device e drying of the nose mouth or throat nosebleed e bloating e ear or sinus discomfort eye irritation e skin rashes e chest discomfort Introduction Parts of the S8 Series Il system Your S8 Series I device comprises e S8 Series I device e Power cord e Carry bag e 2m air tubing Optional components include Integrated humidifier Front cap 3m air tubing e DC 12 converter e ResMed Tubing Wrap Carry handle Screen Keypad Data Card slot Air outlet DC AC Masks A list of masks and their settings compatible with these devices can be found on www resmed com on the Products page under Service and Support Humidifiers A list of humidifiers compatible with ResMed devices can be found on www resmed com on the Products page under Service and Support ResScan Data Card The ResScan Data Card may be used with the S8 Series II either to help your clinician monitor your treatment or provide you with updates to your device settings Using the S8 Series Il Setting Up 1 2 3 4 Connect the power cord to the socket at the rear of the S8 Series II device Plug the other end of the power cord into the power outlet Connect one end of the air tubing firmly onto the air outlet Connect the assembled mask system to the free end of air tubing For information on assembling your ma
24. wer is not connected Ensure the power cable is connected and the power switch if available is on Insufficient air delivered from S8 Series Il device Ramp or settling time is in use Wait for air pressure to build up or change ramp or settling time Air filter is dirty Replace air filter Air tubing is kinked or punctured Straighten or replace tubing Air tubing not connected properly Check air tubing Mask and headgear not positioned Adjust position of mask and headgear correctly Cap s missing from access port on Replace cap s mask Pressure required for treatment may See your clinician to adjust the pressure have changed Device does not start when you breathe into the mask although your clinician has enabled SmartStart Power cord not connected properly Connect power cord firmly at both ends Power outlet may be faulty Try another power outlet Leak Alert has been enabled by your Contact your clinician clinician SmartStart automatically disabled Use of a ResMed Full Face mask SmartStart does not work with a full face mask as the anti asphyxia valve will not allow sufficiently high pressure on exhalation Breath not deep enough to trigger Take a deep breath in and out through the mask SmartStart Problem Possible Cause Solution Excessive leak Adjust position of mask and headgear Replace caps if missing from ports on mask Air tubing may not be connected properly Connect firmly at both ends