Home

Rangemaster RM50000 Series Ventilation Hood User Manual

image

Contents

1. RM50000 Series 5 lt U U 3 ENGLISH 2 FRAN AIS 8 SPANOL aa 14 Broan NuTone LLC 926 West State Street Hartford WI 53027 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 READ AND SAVE THESE INSTRUCTIONS WARNING SUITABLE FOR USE IN HOUSEHOLD COOKING AREA TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions con tact the manufacturer at the address or tele phone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards includ ing fire rated construction codes and stan dards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chim ney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturers guidelines and safety stan dards such as those published by the National Fire Protection Association NFPA and the American Societ
2. GARANTIE BROAN NUTONE LLC LIMIT E UN AN Broan NuTone LLC garantit au consommateur acheteur de ses produits que ces produits seront sans d fauts concernant les mati res employ es et concernant la fabrication pendant une p riode d un an partir de la date d achat IL N Y A AUCUNE AUTRE GARANTIE EXPLICITE OU IMPLICITE Y COMPRIS MAIS NON PAS LIMITEEA LES GARANTIES IMPLICITES OU CONCERNANT LA CAPACITE COMMERCIALE OU LA CONVENANCE POUR TOUT BUT PARTICULIER Pendant cette p riode d un an Broan NuTone LLC r parera ou remplacera s il le jugera n cessaire gratuitement tout article ou toute pi ce qui r sulteront d fectueux condition qu ils aient t utilis e et entretenu correctement CETTE GARANTIE NE SETEND PAS AUX INTERRUPTEURS DES NEON NEON LAMPES HALOGENES AMPOULES d ILLUMINATION Cette garantie ne couvre pas a l entretien normal ni b tout article ou toute pi ce qui aient subi une utilisation erron e une n gligence un accident un entretien erron ou une r paration autre que de la part de Broan NuTone LLC une installation d fectueuse ou bien une installation ne respectant pas les instructions d installation recommand es La dur e de toute garantie implicite est limit e un an comme cela est sp cifi dans la garantie explicite Quelques tats ne permettent pas de limites quant la dur e d une garantie implicite par cons quent la limitation indiqu e ci dessus peut ne pas vous concerner LOBLIGATION
3. n 14 INSTALACION DEL SALPICADERO oorcionat RE i TEJADO 15cm Si se usa un modelo con salpicadero sujete DE primero ste a la pared Asegure los tornillos de PIRETA montaje de la campana al salpicadero y prescinda de la estructura de montaje en la 77e pared abajo descrita E TUBO DECORATIVO INSTALACION DEL TUBO DE campana EN NPS anouro EXTRACCION 15cm DE ee SC HS DIAMETRO NOTA para evitar el riesgo de incendio use AT au solamente material de metal DE LA ZO A DE 1 Decida donde va a colocar el tubo de On extracci n entre lacampana y la parte exterior 2 Un recorrido de tubo corto y recto permitir a la campana funcionar de manera m s eficaz 3 Losrecorridoslargosdetubo codos y manguitos impiden el buen funcionamiento de lacampana Use el menor n mero de ellos posible 4 Instale una cubierta O una tapa Una el tubo de metal de 6 15cm de di metro a la cubierta y retroceda hasta la posici n de la campana Use une cinta para precintar las juntas entre las partes del entubado n 36 3 4 93 5cm si la distancia entre la N STALACIO N D E LOS campana y la zona de cocci n es de 24 61cm SO PO RTES PARA EL 42 3 4 109cm si la distancia entre la campana MO NTAJ E y la zona de cocci n es de 30 76cm 1 Construya una estructura de madera en la pared que quedar nivelada con la parte interior de los tacos en la pared Aseg rese de que a La estructura se
4. the hood should be 24 to 30 above the cooking ADDITIONAL surface MOUNTING 2 Height adjustment i MOUNTING screws provide vertical i BRACKET adjustment 3 Secure the hood with o additional mounting RECTANGULAR screws Use drywall NON lt CUTOUT anchors provided if wall studs or framing are not available WIRING Note This range hood must be properly grounded The unit should be installed by a qualified electrician in accordance with all I 33 7 16 applicable national and local electrical 85cm codes GROUNDING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use an extension cord If the power supply cord is too short have a qualified electrician install an outlet near the appliance Set the electrical power supply within the space covered by the decorative flues Position the power socket at a maximum distance of 33 7 16 850 mm from
5. DE REPARER OU DE REMPLACER DE LAPART DE BROAN NUTONE LLC SERA LE SEUL ET EXCLUSIF REMEDE DE L ACHETEUR COUVERT PAR CETTE GARANTIE BROAN NUTONE LLC NE SERA PAS RESPONSABLE DES DOMMAGESACCIDENTELS CONSEQUENTIELS OU SPECIAUX DUS A L UTILISATION DU PRODUIT O A SA PERFORMANCE OU EN ETANT LA CONSEQUENCE Quelques tats ne permettent pas l exclusion ou la limitation des dommages accidentels ou cons quentiels par cons quent la limitation indiqu e ci dessus peut ne pas vous concerner Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir d autres droits qui varient d Etat Etat Cette garantie d passe toute garantie pr c dente Pour avoir droit la garantie vous devez a avertir la Maison Broan NuTone LLC l adresse indiqu e ci dessous ou t l phoner 1 800 637 1453 b donner le num ro du mod le et l identification de la pi ce d fectueuse et c d crire la nature de tout d faut de l article ou de la pi ce Au moment o vous demandez le service de garantie vous devez pr senter la preuve d achat avec la date Broan NuTone LLC 926 West State Street Hartford WI53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario L5T 1H9 1 888 882 7626 LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INDICADO PARA EL USO EN COCINAS DOMESTICAS PARA EVITAR EL RIESGO DE INCENDIO CORTOCIRCUITO O DAN
6. gler l alimentation lectrique dans l espace couvert par le conduit d coratif Placer la prise femelle a une distance maximum de 33 7 16 85 cm de l endroit o le plomb sort de la hotte voir lillustration ci contre S assurer qu il n y ait pas d interf rence avec la zone de fixation du support ou avec le conduit d coratif l endroit o la gaine touche le mur Mettre la fiche dans la prise femelle CONNEXION DU SYSTEME D EVACUATION R gler la largeur de l trier de support du conduit l aide des vis A indiqu es sur la Figure Fixez l trier de supportau plafond au moyen des vis B et des chevilles comme cela est indiqu ETRIER DE SUPPORT Mod le avec tuyau d vacuation 1 Reliez le collier d vacuation qui se trouve sur votre hotte au syst me de conduction qui se trouve au dessus au moyen d un tuyau rond en m tal de 6 15cm 2 Utilisez un ruban pour tuyauterie afin de rendre toutes les jonctions sures et tanches 3 introduire le conduit d coratif en le pla ant sur la hotte 4 Porter le conduit d coratif sup rieur jusqu au plafond et le fixer avec 2 vis C CONDUIT D CORATIF RUBAN POUR TUYAUTERIE ATTACHEZ LE CONDUIT DECORATIF A L TRIER DE SUPPORT AU MOYEN DES VIS C TUYAU ROND EN METAL DE 6 15cm Mod le recyclant Fair 1 Faites tourner le conduit d coratif sup rieur vers le bas de sorte que l vacuation de Fair soit vers le haut Faites
7. use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth For stubborn cases use a plastic scouring pad or soft bristle brush together with cleanser and water Rub lightly in direction of polishing lines or grain of the stainless finish Avoid using too much pressure which may mar the surface DO NOT allow deposits to remain for long periods of time DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these com pounds contain chemicals which may be harmful Rinse with water after expo sure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only OPERATION IRE SWITCH Controls The hood is operated using the slide controls under the bottom of the hood The light switch turns the lamps on and off Theblower switch makes it possible to select the motor operating speed Position 0 motor Off The pilot lamp lights up whenever the blower is on LIGHT BULBS This range hood requires two 40 Watt light bulbs included ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE To change bulbs 1 Remove the screw securing the light fitting 2 Replace with light bulbs of the s
8. 88370 Bride de raccordement B03202433 Plaquette logo B032904990 Serre cable BE3343338 Tube inf rieur BE3343339 Tube sup rieur B08091335 Etrier montage tube B03295016 D flecteur B032920170 Boite cable alimentation B032920180 Couvercle boite cable alimentation BR2300132 Borne B032920200 Serre cable B03292200 Serre cable B03295029 Boite installation electrique B03295008 Boite installation electrique B03295030 Couvercle boite installation electrique B03295031 Couvercle cable alimentation BE3343337 Support B02011113 Reflecteur B08086255 Circuite commandes B03201014 Lampe temoin B03295032 Bouton moteur B03295033 Bouton lumi re BE3344985 Etrier support convoyer B03295034 Fermeture B06001983 Ensemble convoyer Comprenant N 45 48 49 53 B08999634 Ensemble filters version recyclage Comprenant N 2 filtres llustrees separement 21 LISTA DE PIEZAS DE RECAMBIO RM50000 SERIES RANGE HOOD COD N PIEZAN DESCRIPCI N B08087292 Filtro antigrasa B02300233 Condensador BE3244974 Soporte de la caja de instalaci n el ctrica B02300264 L mpara B02300280 Soporte de la l mpara B03200618 Tapa de la l mpara BW0000019 Convoyador B02310177 Motor B03295000 Manilla de motor B03202007 Almohadilla antivibraziones B03295018 Reduccion B02300248 Cabos B08088370 Conector del aire B03202433 Placa marca B032904990 Sujeta cabos BE3343338 Tubo decorativo inferior BE3343339 Tubo decorativo superior B08091335 Soporte de mo
9. BE3244974 Electrical Box Support B02300264 Lamp Bulb B02300280 Lampholder B03200618 Light Diffuser BW0000019 Blower B02310177 Motor B03295000 Blower Wheel B03202007 Rubber Washer B03295018 Outlet Reduction B02300248 Feeder Cable B08088370 Outlet Flange B03202433 Logo B032904990 Runner Wires BE3343338 Decorative Flue Bottom BE3343339 Decorative Flue Top B08091335 Flue mounting Bracket B03295016 Ductfree Plenum B032920170 Feeder cable connection Box B032920180 Feeder Cable Connection Box Cover BR2300132 Junction Clamp B032920200 Electrical Box Wires Stop B03292200 Feeder Cable Clamp B03295029 Electrical Box Switch Assy B03295008 Electrical Box Capacitor B03295030 Electrical Box Cover B03295031 Feeder Cable Cover BE3343337 Bracket B02011113 Reflector B08086255 Controls Board B03201014 Warning lamp B03295032 Motor Switch Button B03295033 Light Switch Button BE3344985 Blower Support Bracket B03295034 Closing B06001983 Blower Assembly Includes Key Nos 45 48 49 53 B08999634 Ductfree filters KIT Includes Nos 2 filters Not shown assembled 20 LISTE PIECES DE RECHANGE RM50000 SERIES RANGE HOOD ON PART N DESCRIPTION B08087292 Filtre anti graisse B02300233 Condensateur BE3244974 Support boite installation electrigue B02300264 Lampe B02300280 Douille B03200618 Plafonnier BW0000019 Convoyer B02310177 Moteur B03295000 Turbine B03202007 Pare chocs B03295018 R duction B02300248 Cable alimentation B080
10. Basado en Seguridad antifuego en la cocina publicado por NFPA ADVERTENCIA 1 Para reducir el riesgo de incendios y para evacuar correctamente los humos asegurarse de haber realizado una conducci n del aire hasta el exterior No expulsar los humos en espacios cerrados por paredes otechos ticos espacios angostos o garajes 2 Prestar la m xima atenci n al utilizar productos de limpieza o detergentes 3 Evitar el uso de productos alimentarios que puedan inflamarse bajo la campana 4 S lo para ventilaci n total No use gases de escape peligrosos o materiales y vapores explosivos 5 Para evitar da os en el funcionamiento del motor e impulsores ruidosos y o desequi librados mantenga alejados de la unidad de encendido pulverizadores en seco o polvo 6 Elmotortiene un nivel de sobrecarga t rmica que apaga autom ticamente el motor cuando se ha recalentado excesivamente El motor se pone de nuevo en fincionamento cuando la temperatura baja Si el motor comienza a encenderse y a apagarse deber hacer una revisi n de ste 7 Para limpiar mejor las impurezas al cocinar la parte inferior de la campana debe estar a una temperatura m nima de 24 grados y m xima de 30 grados por debajo de la temperature de la zona de cocci n 8 Debido a su gran tama o y peso se recomienda su montaje por parte de dos t cnicos esperializados 9 Se recomienda leer la placa de caracte risticas del producto para ulterior informaci
11. CIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGESARISING OUT OF OR IN CONNEC TION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone LLC at the address stated below or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario LST 1H9 1 888 882 7626 LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENTS PEUT TRE UTILIS DANS LES ZONES CUISSON DES CUISINES FAMILIALES POUR REDUIRE LES RISQUES D INCENDIE DE DECHARGES ELECTRIQUES OU DE DOMMA GES AUX PERSONNES OBSERVEZ LES IN STRUCTIONS SUIVANTES 1 N utilisez cetappareil que comme cela estindiqu parle constructeur Sivous avez des probl mes contactez le fabriquant a l adresse ou au num ro de t l phone indiqu s dans la garantie Ava
12. Class ABC extin guisher and you already know how to op erate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips pub lished by NFPA CAUTION 1 Toreduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages 2 Take care when using cleaning agents or detergents 3 Avoid using food products that produce flames under the Range Hood 4 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 5 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 6 Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced 7 For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking sur face 8 Two installers are recommended because of the large size and weight of this hood 9 Please read specification label on product for further information and requirements INSTALL BACKSPLASH oprionai If optional backspla
13. ERACI N ES NECESARIO DESCONECTAR EL APARATO Para cambiar las l mparas 1 Quite el tornillo que sujeta las l mparas 2 Sustituir con l mparas del mismo tipo ATENCION LAS LAMPARAS PUEDEN ESTAR CALIENTES GARANTIA GARANTIA BROAN NUTONE LLC POR UN A O Broan NuTone LLC garantiza al consumidor comprador de sus productos que dichos productos no tendr n defectos en los materiales o fabricaci n durante un periodo de un a o a partir de la fecha de la compra NO HAY OTRO TIPO DE GARANTIAS QUE INCLUYAN O SE LIMITEN EXCLUSIVAMENTE A GARANTIAS IMPLICITAS O DE CAPACIDAD COMERCIAL O CONVE NIENCIA PARA UN PROPOSITO ESPECIFICO Durante el periodo de un a o Broan NuTone LLC si lo estima conveniente reparar o reemplazar sin gastos para el usuario cualquier producto o parte de ste que sea defectuosos habi ndose usado correctamente ESTAGARANTIA NO CUBRE ESTARTER DE NEON NEON L MPARAS HALOGENAS L MPARAS DE ILUMINACI N Tampoco cubre el mantenimiento ni los productos o partes de stos que hayan sido usados de forma incorrecta con negligencia rotos accidentalmente o por una incorrecta manutenci n reparaci n distinta da la realizada por Broan NuTone LLC montaje incorrecto instalaci n que no se ajuste a las instrucciones de montaje indicadas Le duraci n de la garant a se limita al periodo de un a o como est especificado en la garant a explicita Algunos paises no permiten un limite en la duraci n de la garant a imp
14. O PARA LAS PERSONAS OBSERVE ATENTAMENTE LAS SIGUIENTES NORMAS 1 Use esta unidad solamente de la manera indicada por el fabricante si tiene dudas p ngase en contacto con ste a la direcci n o tel fono indicados en la garant a 2 Antes de hacer una revisi n o de limpiar la unidad descon ctela de la red para evitar que se encienda de manera accidental En el caso de que ste no pueda ser desacti vado se indicar en la placa de caracte risticas 3 Elmontaje y la instalaci n el ctrica debe hacerlos un t cnico especializado siguiendo las normas est ndar e incluyendo aquellas de construcci n anti incendio 4 Necesita aire suficiente para una apropiada combusti n y escape de gases a trav s del tubo del dep sito de quema de combustible Para evitar que el humo aspirado vuelva a la cocina siga las directivas del fabricante y las normas est ndar de siguridad asi como las normas publicadas porla Asociaci n de prevenci n de incendios NFPA y la Socie dad americana de especialistas en cale facci n refrigeraci n y aire acondicionado y adem s las normas de las autoridades locales 5 Hacer un corte o un taladro en la pared o en el techo no debe da ar la instalaci n el ctrica u otras instalaciones ocultas en la pared 6 Losconductos ventiladores deben siempre desalojar al exterior 7 No use esta unidad con dispositivo de control de la velocidad a estado s lido 8 Para evitar el riesgo de incendio use solame
15. UNE POELE OU UNE CASSEROLE QUI A PRIS FEU Vous pourriez vous br ler NUTILISEZ PAS D EAU ni torchons ou serviettes mouill s vous provoqueriez une violente explosion de vapeur Utilisez un extincteur SEULEMENT si A Vous savez que vous avez un extincteur Classe ABC et vous en connaissez d j le mode d emploi Ce n est pas un tres gros incendie et qu il se limite l endroi o il a explos Vous tes en train d avertir les pompiers Vous avez la possibilit d essayer d teindre l incendie en ayant le dos tourn vers une issue D apr s les Suggestions concernant la S curit contre les incendies des cuisines publi es par NFPA ATTENTION B C D 1 Pour r duire tout risque d incendie et pour vacuer correctement l air assurez vous de pr voir un conduit de ventilation ext rieur Ne videz pas l air dans les espaces limit s par des murs ou des plafonds les combles les passages troits ou les garages Faites tr s attention quand vous utilisez des produits de nettoyage ou des d tergents Evitez d utiliser des aliments pouvant s enflammer sous la Range Hood N utilisez cet appareil que pour une ventilation g n rale Ne Putilisez pas pour vacuer des mati res ou des vapeurs dangereuses ou qui peuvent exploser Pour viter de causer des dommages au moteur et de rendre les rotors bruyants et ou non quilibr s vitez que les sprays pour murs secs la poussi re de construction e
16. ame type CAUTION BULB MAY BE HOT WARRANTY BROAN NUTONE LLC ONE YEAR LIMITED WARRANTY Broan NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WAR RANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITEDTO IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FORA PARTICULAR PURPOSE During this one year period Broan NuTone LLC will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENDT BULBS This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDERTHIS WARRANTY BROAN NUTONE LLC SHALL NOT BE LIABLE FOR IN
17. arriba TUBO 2 Use cinta para ajustar todas las junturas y i DECORATIVO que quede herm tico lt 3 Introduzca el tubo decorativo conect ndolo en la campana 4 Extienda la parte superior del tubo decorativo hacia el techo y suj tela con 2 tornillos C FIJE LA PARTE _ SUPERIORE DEL TUBO A AL SOPORTE CON TUBO DE METAL DE 6 15CM DE DI METRO Configuraci n sin tubo PARTE SUPERIOR REJILLAS DE SOPORTE 1 D la vuelta a la parte superior DEL TUBO SALIDA DEL AIRE SUPERIOR configuraci n sin del tubo de manera que las tubo rejillas de salida del aire est n en la parte superior Haga deslizar la parte superior del tubo hasta RESPIRADERO alcanzar la parte inferior de ste 2 Una el respiradero de aire con la PARTE INFERIOR parte superior del tubo por medio de cuatro tornillos con cabeza plana adjuntos TUBO DE METAL DE 5 12 5 DE 3 Instale el reductor en el collar de aa aaa U descarga 4 Mida la distancia desde la parte REDUCTOR superior del reductor hasta el _ 1 1 Il techo Corte a una distancia de 5 COLLAR DE 12 5 cm alrededor del tubo de DESCARGA metal 5 m s corto que su medida 5 Instale el tubo en el orificio Para una mejor instalaci n asegurarse de que la juntura del tubo se encuentre en la parte frontal 6 Instale el tubo en la campana con la parte superior inclinada con respecto a la pared Alargar el borde del tubo para sujetarlo a la parte inferior de
18. die n utilisez que des conduits en m tal 9 Votre appareil doit tre reli la terre ATTENTION POUR REDUIRE LES RISQUES D INCENDIE DES MATIERES GRASSES QUI SONT EN TRAIN DE CUIRE A Ne laissez jamais ni vos l ments chauffants ni vos casseroles ou po les sur le feu sans les contr ler si vous r glez l apport de chaleur sur une position lev e Si vos casseroles ou po les d bordent cela provoque de la vapeur et des claboussures de graisse qui peuvent prendre feu Chauffez les huiles lentement feu bas ou moyen Faites toujours fonctionner votre hotte quand vous cuisez des temp ratures lev es ou quand vous cuisinez des plats flamb s Nettoyez r guli rement les ailes de vos ventilateurs Ne permettez pas que la graisse s accumule sur le ventilateur ou sur le filtre Utilisez des casseroles de taille appropri e Utilisez toujours des ustensiles de cuisson dont la taille est appropri e la surface de votre l ment de cuisson o ND an 8 AVERTISSEMENTS POUR REDUIRE LES RISQUES DE DOMMAGES AUX PERSONNES AU CAS OU VOTRE CUISI NIERE PRENDRAIT FEU OBSERVEZ LES INSTRUCTIONS SUIVANTES 1 ETEINDRE LES FLAMMES l aide d un couvercle le plus herm tique possible une plaque a g teaux ou un plateau en m tal puis teindre le br leur ATTENTION NE PAS VOUS BRULER Siles flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS NE PRENEZ JAMAIS EN MAIN
19. ee plenum For best fit make sure duct seam is toward the front Set duct flue assembly on hood with top tilted away from wall Reach around flue to engage bottom of duct with discharge DUCTFREE PLENUM LOWER FLUE SECTION DU 5 ROUND METAL AP U REDUCTION A DISCHARGE COLLAR collar on hood Tilt flue up against wall Duct seam can be cut to length if necessary Extend the upper flue to the ceiling and secure with the 2 screws C DUCTFREE FILTER INSTALLATION 1 Ductfree filter kit B08999634 is included 2 Position the filters over the blower 3 Rotate to lock filters in place FILTERS MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit Grease Filter The grease filter should be cleaned fre quently Use a warm detergent solution Grease filter is dishwasher safe GREASE FILTER Remove filter by pushing filter towards the back of hood and rotating filter downward Ductfree Filters The ductfree filters should be changed every 6 months Rotate the filters to remove and replace Hood Cleaning Stainless steel is one of the easiest materials to keep clean Occasional care will help preserve its fine appearance Cleaning tips Hot water with soap or detergent is all that is usually needed Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks For discolorations or deposits that persist
20. encuentra centrada por encima de la instalaci n del tubo b La altura de la estructura permite fijar los soportes para el montaje en esta estructura siguiendo las dimensiones indicadas 2 Una vez que la superficie de la pared est acabada sujete los soportes para el montaje siguiendo las dimensiones indicadas INSTALACION DE TORNILLOS PARA ESTRUCTURA DE MADERA EN LA CAMPANA LA REGULACION LA PARED ee DE LA ALTURA 1 Cuelgue la campana del soporte por el agujero rectangulare situado ORNILLOS PARA z MONTAJE detr s de la campana El ADICIONALES agujero es m s grande SOPORTE DE que el soporte para MONTAJE permitir el ajuste en horizontal infari gt AGUJERO La parte inferior de la ES PA GULARE campana debe estar a una distancia de 24 61cm 6 30 76cm por encima de la zona de cocci n 2 Los tornillos para la regulaci n de la altura permiten un ajuste en vertical 3 Sujete la campana con tornillos para montaje adicionales Use escarpias si no dispone de tacos o de la estructura de soporte en madera INSTALACION ELECTRICA Nota Este tipo de campana tiene que ser conectada a tierra cuidadosamente La unidad debe instalarla un t cnico electricista siguiendo las normas nacionales y locales INSTRUCCIONES DE CONEXION A TIERRA Este aparato se debe conectar a tierra En caso de cortocircuito la conexi n a tierra reduce el riego de electrocuci n ya que posee un hilo de descarga a tierra pa
21. face NE LAISSEZ PAS les taches trop longtemps N UTILISEZ PAS de laines d acier ordinaires ou des brosses en acier Des d bris d acier pourraient adh rer la surface et causer de la rouille NE PERMETTEZ PAS que des solutions sal es des d sinfectants des blanchissants ou des produits nettoyants restent en contact avec l acier pendant longtemps Beaucoup de ces produits contiennent des produits chimiques qui pourraient causer des dommages Rincez l eau imm diatement s ils entrent en contact et essuyez avec un chiffon humide Les surfaces peintes doivent tre nettoy es avec de l eau ti de additionn e d un d tergent doux seulement 12 FONCTION NEMENT INTERRUPTEUR INTERRUPTEUR DU DE LA VENTILATEUR Commandes LUMI RE VOYANT La hotte peut tre manceuvr e l aide des LUMINEUX curseurs situ s sous la partie inf rieure de la hotte l interrupteur de la lumi re allume et teint les lampes Linterrupteur du ventilateur permet de s lectionner la vitesse de marche du moteur Position 0 moteur teint Le voyant lumineux s allume quand le ventilateur fonctionne AMPOULES Ce mod le de hotte veut 2 lampes type 40 Watt fournies AVANT DE PROC DER QUELCONQUE OPERATION D BRANCHEZ L APPAREIL Pour changer les ampoules 1 Enlever la vis fixant le syst me d clairage 2 Remplacer par un tube ayant les m mes caract ristiques ATTENTION LE TUBE PEUT ETRE CHAUDE GARANTIE
22. glisser le conduit d coratif sup rieur dans le conduit d coratif inf rieur EVACUATION DE ETRIER DU L AIR mod le recyclant Pair CONDUIT DECORATIF SUPERIEUR S 2 Reliez le d flecteur au conduit d coratif sup rieur au moyen de 4 vis a t te plate qui vous sont fournies 3 Installer le r ducteur sur le collier d vacuation 4 Mesurer la distance du haut du CONDUIT DECORATI INFERIEUR MESURE TUYAU ROND EN METAL DE 5 12 5cm r ducteur au plafond Couper une REPUCTEUR longueur de tuyau rond en m tal de 5 12 5cm plus petit que cette dimension 5 Placer le jonction du tuyau au dessus du deflecteur Pour une adaptation parfaite s assurer que le jonction du tuyauest orient vers l avant 6 Placer l ensemble conduit tuyau sur la hotte avec la partie sup rieure inclin e loin du mur Tendre le tuyau pour engager le bas du tuyau dans le collier d vacuation sur la hotte Incliner le tuyau vers le haut contre le mur Le jonction du tuyau peut tre coup en longueur si n cessaire 7 Faire arriver le conduit d coratif sup rieur jusqu au plafond et le fixer l aide de 2 vis C 11 COLLIER D EVACUATION ASSEMBLAGE DES FILTRES MODELE RECYCLANT LAIR 1 L ensemble filtres version recyclage B08999634 est fourni 2 Placez les filtres au dessus du ventilateur Gr ce un mouvement rotatif fixez les filtres leur place ENTRETIEN Un bon en
23. l tubo mediante el collar de descarga en la campana Inclinar la parte superior del tubo decorativo contra la pared La juntura del tubo se puede cortar longitudinalmente si es necesario 7 Extendienda la parte superior del tubo hacia el techo y suj tela con 2 tornillos C 17 INSTALACION DOS FILTROS CONFIGURACION SIN TUBO 1 2 3 MANTENIMIENTO Un mantenimiento adecuado de la campana asegura el funcionamiento correcto del aparato Filtro antigrasa El filtro antigrasa debe limpiarse a menudo El juego de filtros de ricambio de aire B08999634 es adjunto Instale los filtros sobre el aspirador Gire los filtros para ajustarlos en su sitio FILTROS Use un detergente que no sea fuerte FILTROANTIGRASA El filtro antigrasa se puede meter en el lavavajillas Extraiga el filtro tirando de ello hacia atr s de la campana y gir ndolos hacia abajo Filtros configuraci n sin tubo Los filtros deben cambiarse cada seis meses Gire los filtros para desenroscarlos y cambiarlos Limpieza de la campana El acero inoxidable es uno de los meteriales m s f ciles de limpiar pero ser a aconsejable un especial cuidado en su uso para mantenerla en buen estado La campana se puede limpiar de las siguientes maneras Agua caliente con jab n o detergente es la mejor manera para limpiarla Acl rela con agua corriente s quela con un pa o suave y limpio para evitar las huellas que deja el agua Para las mancha
24. licita si es asi en su caso esta limitaci n arriba indicada podr a no aplicarse LA PRESENTE GARANTIA CUBRIRA EXCLUSIVAMENTE AL COMPRADOR LOS SERVICIOS DESCRITOS ANTERIORMENTE BROAN NUTONE LLC NO SE HACE RESPONSABLE DE DANOS PRODUCIDOS DE MANERA ACCIDENTAL O RELACIONADOS CON EL USO INCORRECTO DEL PRODUCTO O SU FUNCIONAMIENTO Algunos paises no permiten la exclusi n o limitaci n de los da os producidos de manera accidental si es as en su caso esta limitaci n arriba indicada podr a no aplicarse Esta garant a le da derechos legales espec ficos y podr a tambi n disponer de otros derechos que varian de pa s a pa s Esta garant a supera otras garant as dadas con anterioridad Para disfrutar de la garant a usted deber a Avisar a la direcci n abajo indicada bien llamar por tel fono al n mero 1 800 637 1453 b Dar el n mero de serie del modelo correspondiente o bien una descripci n de la parte averiada c Descripci n del defecto en el producto o bien en una de sus partes Para requerir un servicio en garant a debe presentar el justificante con la fecha de la compra Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario LST 1H9 1 888 882 7626 SERVICE PARTS RM50000 SERIES RANGE HOOD KEY NO PART NO DESCRIPTION B08087292 Grease Filter B02300233 Motor Capacitor
25. nt de pourvoiral entretien ou au nettoyage de votre appareil teignez le au tableau des commandes ou bloquez le tableau des commandes afin d viter de le mettre en marche accidentellement Sivous ne pouvez pas bloquer le systeme permettant d teindre votre appareil appliquez un avertissement ext rieur d une facon sure comme par exemple un panneau sur le tableau des commandes L assemblage etla connexion lectrique doivent tre faits par des personnes qualifi es en respectantles normes et r glements en vigueur y compris les normes et r glements concernantles possibilit s d incendie llestindispensable qu il y ait suffisamment d air pour que la combustion et l vacuation des gaz travers le tuyau du br leur du combustible aitlieu sans retour de flamme Suivez les indications donn es parle fabricant du br leur ainsi que les normes de s curit comme celles qui sont publi es par l Association Nationale pour la Protection contre les incendies National Fire Protection Association NFPA etla American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE etles autorit s locales en mati re de normes Quand vous coupez ou percez des trous dans le mur ou le plafond n abimez pas les fils lectriques ou autres Le ventilateur canalis doit toujours vacuer l air vers l ext rieur N utilisez pas cet appareil avec un appareil contr lant la vitesse tat solide Afin de diminuer tout risque d incen
26. ntaje del tubo B03295016 Desviador del aire B032920170 Caja cabos alimentaci n B032920180 Tapa de la caja cabos alimentaci n BR2300132 Terminal B032920200 Sujeta cabos B03292200 Sujeta cabos B03295029 Caja de instalacion el ctrica B03295008 Caja de instalacion el ctrica B03295030 Tapa de la caja de instalacion el ctrica B03295031 Tapa cabos alimentacion BE3343337 Soporte B02011113 Reflector B08086255 Base de los mandos B03201014 Piloto B03295032 Mando motor B03295033 Mando iluminaci n BE3344985 Soporte convoyador B03295034 Sierre B06001983 Conjunto motor Incluye los N 45 48 49 53 B08999634 Conjunto filtros configuraci n sin tubo Incluye N 2 filtros Se encuentran por separado 22 SERVICE PARTS LISTE PIECES DE RECHANGE LISTA DE PIEZAS DE RECAMBIO RM50000 SERIES RANGE HOOD mO SF O 20 dire er eo CO cul co D m A 165 03295029 og Ol O Ol kad A A A lm Mh ar bu 08999634 23 04306792 2
27. nte conductos de metal 9 Esta unidad tiene que ser conectada a tierra PARA EVITAR EL RIESGO DE FUEGO PORALTO NIVEL DE GRASA A Nunca abandone los quemadores con el fuego alto La cocci n causa humo y restos de grasa que pueden arder Caliente el aceite a fuego medio o bajo B Encienda siempre la campana cuando cocine a fuego alto o cuando cocine alimentos f cilmente inflamables C Limpie con frecuencia los ventiladores No se debe acumular grasa en el ventilador o en el filtro D Usa eltama p de cazuela apropiado Use siempre utensilios de cocina de tama o y material adecuados ADVERTENCIA PARA EVITAR EL RIESGO DE DANOS A PERSONAS EN CASO DE FUEGO POR ALTO NIVEL DE GRASA TENGA EN CUENTA LO SIGUIENTE 1 SOFOQUE LA LLAMA con una tapadera apropiada una bandeja met lica un utensilio de coc na que pueda cubrirla despues apague el quemador ACTUE CON PRECAUCION PARA EVITAR QUEMA DURAS Si la llama no se extingue inmedia tamente SALGA Y LLAME ALOS BOMBE ROS 2 NUNCA COJA UNA SARTEN EN LLAMAS porque corre el riesgo de quemarse 3 NO USE AGUA ni pa os o toallas h midas porque puede provocarse una violenta humareda 4 Use un extintor SOLAMENTE si A Posee un extintor de clase ABC y sabe perfectamente c mo usarlo B Elfuego es peque o y est controlado en el mismo sitio en que empez C Hallamado con anterioridad a los bomberos D Puede combatir el fuego retrocediendo hacia la salida
28. ntrent en contact avec la partie lectrique Le moteur de votre hotte a un thermostat qui teindra automatiquement le moteur s il est surchauff Le moteur se remettra en marche lorsqu il se sera refroidi Si le moteur continue s teindre et se remettre en marche faites v rifier votre hotte Pour mieux capturer les impuret s de cuisine le bas de votre hotte devrait tre une distance minimum de 24 et une distance maximum de 30 au dessus du plan de cuisson Vu que cette hotte est grande et lourde il est recommand de confier l installation de cette hotte deux personnes Nous vous recommandons de lire l tiquette indiquant les caract ristiques de votre hotte pour de plus amples informations et exigences INSTALLATION DU PANNEAU re POSTERIEUR oo TUYAU ROND m DE 6 15cm ra Si vous avez choisi d utiliser le panneau post rieur accrochez le au mur Fixez les triers d assemblage au panneau mais nassemblez pas le cadre allant contre le mur qui est d crit FA AAS S LS A ISIN CONDUIT plus bas D CORATIF E INSTALLATION DU SYSTEME HOTTE i D EVACUATION J REMARQUE Pour r duire les risques pE o ink d incendie n utilisez que des tuyaux en m tal DU PLAN DE CUISSON X 1 D cidez o le tuyau rond doit tre install entre votre hotte et l ext rieur 2 Un tuyau droit et court permettra votre hotte de fonctionner d une fa on plus efficace 3 Un tuyau long avec de
29. ra la corriente Este aparato est equipado con un cable que posee un hilo de toma de tierra con una clavija de tierra La clavija se debe conectar a un enchufe instalado correctamente y conectado a tierra ADVERTENCIA una conexi n a tierra incorrecta puede provocar riesgos de electrocuci n Consulte a un electricista calificado si no se entienden o si existe alguna duda sobre la correcta conexi n a tierra No utilice un cable de prolongaci n Si el cable proporcionado es demasiado corto p ngase en contacto con un electricista calificado para que instale un enchufe cerca del aparato Conecte la alimentaci n el ctrica en el espacio cubierto por el tubo decorativo Coloque el enchufe a una distancia m xima de 33 7 16 85 cm desde el cable de la campana v ase figura adjunta Aseg rese de que no interfiera con el rea de la abrazadera de sujeci n o con el tubo decorativo donde el tubo decorativo toca con la pared Conecte la clavija al enchufe ENTUBADO DE CANALIZACION Regule la anchura del tubo montando la abrazadera con los tornillos A como se puede observar en la Figura Use tornillos y escarpias para fijar al techo el soporte para el montaje del tubo como se indica SOPORTE PARA EL MONTAJE DEL TUBO TORNILLOS B TORNILLOS A Configuraci n con tubo 1 Use un tubo de metal de 6 15cm de di metro para unir el collar de descarga que se encuentra encima de la campana al tubo de extracci n situado
30. s coudes et des transitions r duira le bon fonctionnement de votre hotte En utiliser le moins possible 4 Installez un couvercle sur le toit ou au mur Reliez un tuyau en m tal rond de 6 15cm au couvercle et faites le aller jusqu emplacement de votre hotte Rendez les jonctions du tuyau herm tiques au moyen d un ruban pour tuyaux 36 3 4 93 5cm si la distance entre la hotte et N STAL LATI O N D ES ETRI E RS le plan de cuisson c est de 24 61cm D ASS E M B LAG E 42 3 4 109cm si la distance entre la hotte et le plan de cuisson c est de 30 76cm 1 Construisez un cadre en bois pour le mur dont les vis pivot ne d passent pas Assurez vous a que le cadre est centr au dessus de l emplacement de l installation b la hauteur du cadre permettra que les triers d assemblage soient fix s au cadre en respectant les dimensions indiqu es 2 Apr s avoir termin la surface du mur fixez les triers d assemblage au cadre en respectant les dimensions qui sont indiqu es INSTALLATION DE VOTRE HOTTE 1 Accrochez votre hotte trier par le trou VIS rectangulaire qui se D ASSEMBLAGE trouve derri re votre PE SECURITE hotte Le trou est plus grand que l triere afin VIS de vous permettre PASSEMBLAGE d ajuster le tout PE SECURITE horizontalement Ere Le fond de votre hotte devrait tre entre 24 y 7 61 cm et 30 76 cm au m TROU dessus de la surface de Pa RECTANGULAIRE cui
31. s o restos de grasa que persistan use un producto qu mico dom stico que no raye un limpiador para acero inoxidable con poca agua y un pa o suave Si las manchas persisten use un estropajo y un cepillo de cerdas suaves con un producto limpiador y agua Frote suavemente en el sentido del pulido o de las vetas del remate del inoxidable No apriete demasiado porque podr a da ar la superficie No deje que las manchas se acumulen durante mucho tiempo No use utensilios o cepillos de acero Peque as particulas de acero pueden adherirse y oxidarse No use soluciones salinas desinfectantes lej as o productos de limpieza que permanezcan en contacto con el acero inoxidable durante largos periodos de tiempo Muchos de estos productos contienen componentes qu micos que podr an resultar nocivos Aclare con agua y seque con un pa o limpio Las superficies lacadas deben limpiarse solamente con agua tibia y detergente no muy fuerte 18 FUNCIONAMIENTO a E DA LUZ DEL ASPIRADOR Mandos La campana se controla mediante los mandos corrrederos situados en la parte inferior de la misma El interruptor da luz enciende y apaga las l mparas PILOTO El interruptor del aspirador regula la velocidad de trabajo del motor Posici n 0 motor apagado El piloto se enciende cuando el aspirador est funcionando LAMPARAS Este tipo de campana necesita 2 lamparas Tipo 40 WATT adjuntos ANTES DE PROCEDER A CUALQUIER OP
32. sh is used attach it to the finished wall Secure hood mounting bracket to the backsplash and omit wall framing described below ROOF CAP 6 ROUND F A AAS IS SSII SSII U INSTALL THE DUCTWORK S TEE NOTE To reduce the risk of fire use only HOOD Ni metal ductwork T 1 Decide where the ductwork will run 24 TO 30 ABOVE l between the hood and the outside COOKING SURFACE 1 2 Astraight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal ductwork to cap and work back to wards hood location Use duct tape to seal the joints between ductwork sections INSTALL MOUNTING BRACKET 36 3 4 bottom of hood 24 above 1 Construct wood wall framing that is flush cooktop M with interior surface of wall studs ea PALM Oh MOOG SU ADONE cooktop Make sure a the framing is centered over installation location b the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown 2 Afterwall surface isfinished secure mounting bracketto framing using dimensions shown INSTALL THE HOOD 1 Hang the hood from the bracket through the rectangular cut out on the back of the hood Cut out is larger than the bracket to HEIGHT WALL FRAMING allow for horizontal ADJUSTMENT adjustment The bottom of SCREWS
33. sson a 2 Les vis de r glage en hauteur permettent de PLANCHE DE BOIS POURL ADAPTATION r gler verticalement 3 Fixez votre hotte avec des vis d assemblage de securit Utilisez des chevilles pour mur sec qui vous sont fournies si vous ne trouvez pas les vis pivot ou le cadre INSTALLATION ELECTRIQUE Remarque Ce mod le de hotte doit tre reli la terre correctement Cet article devrait tre install par un lectricien qualifi selon les lois nationales et locales en mati re d lectricit INSTRUCTIONS POUR LA MISE A LA TERRE Cet appareil doit tre reli la terre En cas de court circuit la mise la terre r duit le risque de d charge lectrique en fournissant un c ble permettant au courant d tre d vi Cet appareil est quip d un cordon ayant un c ble de mise la terre avec une fiche de mise la terre La fiche doit tre branch e dans une prise de courant correctement install e et mise la terre ATTENTION Une mise la terre incorrecte peut entra ner un risque de d charge lectrique Consulter un lectricien sp cialis si les instructions de mise la terre ne sont pas tout fait compr hensibles ou en cas de doute sur le fait de savoir si l appareil est correctement reli la terre Ne pas utiliser de prolongation Si le cordon d alimentation est trop court demander a un lectricien agr d installer une prise de courant pr s de l appareil R
34. tretien de votre hotte garantira une excellente performance Filtre anti graisse Le filtre anti graisse doit tre nettoy fr quemment Utilisez une solution contenant un d tergent ti de Le filtre anti graisse peut tre lav au lave vaisselle Enlevez le filtre en le poussant vers l arri re de votre hotte et en FILTRES POUR MODELES RECYCLANT L AIR FILTREANTI GRAISSE le faisant tourner vers le bas Filtres pour mod les recyclant l air Les filtres pour mod les recyclant l air doivent tre remplac s tous les 6 mois Faites tourner les filtres afin de les enlever et de les remettre Nettoyage de votre hotte L acier inoxydable est une des mati res les plus faciles nettoyer Un entretien de temps en temps permettra de le conserver en parfait tat Conseils pour le nettoyage Eau chaude et savon ou d tergent est tout ce qui est normalement n cessaire Apr s chaque nettoyage rincez bien l eau claire Essuyez avec un chiffon propre et doux afin d viter les taches d eau Si des d colorations ou des d p ts persistent utilisez un nettoyant domestique non abrasif ou de la poudre pour l acier inoxydable et un peu d eau et un chiffon doux Dans les cas difficiles utilisez une ponge en plastique ou une brosse douce avec du nettoyant et de l eau Frottez l g rement en suivant la direction du polissage ou du grain de l acier inoxydable Evitez de frotter trop fort afin de ne pas abimer la sur
35. where the lead exits from the hood see illustration alongside Make sure this does not interfere with the bracket fastening area or with the decorative pipe where the flue touches the wall Fit the plug into the power socket CONNECT DUCTWORK Adjust the width of the flue mounting bracket using screws A indicated in Figure Use screws B and wall anchors to secure flue mounting bracket to the ceiling as shown FLUE MOUNTING BRACKET SCREWS B SCREWS A Ducted Configuration 1 Use 6 round metal duct to connect the duct collar on the hood to the ductwork above 2 Use duct tape to make all joints secure and air tight 3 Insert the decorative flues setting them on the hood 4 Extend the upper flue to the ceiling and secure with the 2 screws C DECORATIVE FLUE DUCT TAPE FASTEN FLUE TO _ UPPER BRACKET E WITH SCREWS C 6 ROUND METAL DUCT UPPER AIR FLUE SECTION VENTS in upper flue section UPPER BRACKET Ductfree Configuration 1 Turn upper flue section upside down so air vents are at the top Slide upper flue section into F lower flue section Connect the ductfree plenum to the upper flue section with 4 flat head screws supplied Install the reduction on the discharge collar Measure the distance from the top of the reduction to the ceiling Cut a length of 5 round metal duct 5 shorter than this dimension Fit duct section over the ductfr
36. y for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the out doors Do not use this unit with any solid state speed control device To reduce the risk of fire use only steel ductwork This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE A Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings B Always turn hood ON when cooking at high heat or when cooking flaming foods C Clean ventilating fans freguently Grease should not be allowedto accumulate on fan or filter D Use proper pan size Always use cookware appropriate for the size of the surface element O 0 N O WARNING TO REDUCE THE RISK OF INJURY TO PER SONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACU ATEAND CALL THE FIRE DEPARTMENT 2 NEVER PICK UPA FLAMING PAN You may be burned 3 DO NOTUSE WATER including wet dishcloths or towels violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a