Home
Philips 19C5808E Home Theater System User Manual
Contents
1. fj i a Power connection PC connection to computer video card Control locations and functions Descriptions of knobs and keypads on front control panel o Press this knob to switch ON and OFF the monitor s power Activate OSD On Screen Display menu Confirm selection Activate contrast control Activate brightness control Select OSD menu Increase or decrease the setting OSD menu tree structure First Level Main Controls Screen Size amp Position Color Temperature Special Controls Advanced Controls Geometry Controls Second Level T 1 E Third Level Brightness Contrast Degauss EXIT RESET Horizontal Position Horizontal Size Vertical Position Vertical Size EXIT RESET 9300 K CAD CAM 6500 K DTP 5500 K Photo Retouch User Presets Go back to Main EXIT RESET OSD Languages English German French Italian and Spanish monitor status show resolution V amp H freq OSD Controls r Timer Hori position LL L Vert position RESET XE EXIT OFF Default H Moire Moire V Moire Power Saving ON RESET OFF EXIT Pincushion Balanced Pincushion Trapezoid Parallelogram Rotation EXIT RESET Exit Exit OSD and save all previous setting automatically Reset No return to main menu Yes all settings will return to factory default and return to main menu ast o
2. Go back to upper layer Save and exit the COLOR TEMPERATURE settings Reset the COLOR TEMPERATURE settings to functions factory defaults special m ll CJ 1600x1200 93 8K 75HZ Five languages can be chosen English default German French Italian and Spanish loi MONITOR STATUS Indicates the horizontal and vertical frequency and the resolution amp OSD CONTROLS OSD display time amp position control 18 14 OSD CONTROLS 47 TIMER th EXIT RESET TIMER Set OSD display time The OSD display will disappear all settings will be saved automatically VERTICAL POSITION Move the OSD window up or down HORIZONTAL POSITION Move the OSD window left or right Save and exit the SPECIAL CONTROLS settings Reset the SPECIAL CONTROLS settings to factory defaults Advanced Controls advanced amp ca MOIRE Cancels moire distortion MOIRE OFF Disables the cancellation of moire distortion default C HORIZONTAL Increase or decrease the horizontal moire VERTICAL Increase or decrease the vertical moire ca POWER SAVING Switch the power saving On or Off EXIT Save and exit the ADVANCED CONTROLS settings RESET Reset the ADVANCED CONTROLS settings to factory defaults Geometry Controls geometry mm vmm 16 PINCUSHION Change the curvature of the image inward or outward on each side of the Screen BALANCED PINCUSHION Change
3. No Color Color appears blotchy Missing one or more colors Dim Picture Picture is too large or too small Edges of the picture are not square Picture has a double image 24 CHECK THESE ITEMS If you are using a non VESA DDC standard video card consult your local Philips dealer or service organization to obtain an adapter Adjust the DEGAUSS setting Remove any nearby magnetic objects Face the monitor toward the East for best picture quality Check user settings of Color Temperature Make sure the monitor cable is connected properly to your computer Check to see if the monitor cable has bent pins Adjust the Brightness and Contrast controls Check your video card and it s instruction It may be a non VESA DDC Standard card Adjust the Horizontal and or Vertical Size Adjust the geometry controls Eliminate the use of a video extension cable and or video switch box Face the monitor toward the East for best picture quality Picture is not sharp Check to make sure Moire is switched off Unstable Picture Increase your refresh rate Consult your computer manual for details Windows 95 cannot Select Super VGA under STANDARD find your video card DISPLAY TYPES or contact your video card manufacturer for the right drivers For futher assistance contact Philips at 800 835 3506 or 423 475 0280 25 GLOSSARY Here are a few definitions that may help you Degauss
4. UNTEN TT 8 User preset 1 9300 K R G B adjusted independently User preset 2 6500 K R G B adjusted independently User preset 3 5500 K R G B adjusted independently 5 seconds 10 seconds default 25 seconds off Main Controls BRIGHTNESS Increase or decrease brightness level Q CONTRAST Increase or decrease contrast level DEGAUSS Eliminate magnetism EXIT Save and exit the MAIN CONTROLS settings RESET Reset the MAIN CONTROLS settings to factory defaults 10 Screen Size and Position screen Ge HORIZONTAL POSITION HORIZONTAL SIZE VERTICAL POSITION VERTICAL SIZE EXIT RESET Move the image left or right Increase or decrease the horizontal size of the image Move the image up or down Increase or decrease the vertical size of the image Save and exit the SCREEN SIZE amp POSITION settings Reset the SCREEN SIZE amp POSITION settings to factory defaults 11 Color Temperature There are three color temperature preset modes 9300 K for CAD CAM 6500 K for DTP and 5500 K for retouch applications 14 9300 K CAD CAM 24 6500 K DTP 34 5500 K PHOTO RETOUCH USER PRESETS Adjust the Red Green and Blue settings to make a custom color temperature USER PRESETS RED X 0787 GREEN NEEEEEEEEKEKNKNE 75 BLUE MEEEEEEEEEEEEEN 07897 12 4 EXIT RESET Special Controls LANGUAGE
5. regulations on how to dispose of your old monitor IBM IBM PC and Power PC are registered trademarks of International Business Machines Corporation Apple Macintosh Quadra Performa and Centris are registered trade marks of Apple Computer Inc Installation Important Please refer to the user s manuals of your computer and video adapter to make sure the equipment is properly installed and configured before installing the monitor Positioning Ventilation Avoid exposing the monitor to direct sunlight stove or any other heat sources To prevent overheating make sure the ventilation openings of the monitor are not covered Keep moisture and dust away Keep away from any magnetic objects such as speakers electric motors transformers etc When positioning this monitor make sure the power plug and outlet are easily accessible Pedestal With the built in pedestal you can tilt and or swivel the monitor to the most comfortable viewing angle Connection Important Please make sure the AC power to your computer is OFF before connecting or disconnecting any display peripheral Failure to do so may cause serious personal injury as well as permanent damage to your computer equipments Connect the monitor to the computer using the supplied interface cable Connect the power cord to a wall outlet after the interface cable is properly connected
6. video input No pin Green video input Logic ground Blue video input Identical output Identical output connected to pin 10 Connected to pin 10 Serial data line SDA Ground H Sync H V Red video ground V Sync VCLK for DDC Green video ground Data clock line SCL Blue video ground 22 Troubleshooting Having trouble Something not working Before calling for help try these suggestions HAVING THIS PROBLEM CHECK THESE ITEMS No Picture Make sure the Power cable is plugged Power LED not lit into the wall outlet and into the back of the monitor The power button on top of the monitor should be in the ON position Disconnect the monitor from the power outlet for about one minute No Picture Make sure the computer is turned on Power LED is amber Make sure the monitor cable is or yellow connected properly to your computer Check to see if the monitor cable has bent pins The Automatic Power Saving may be activated No Picture Make sure the Brightness and Contrast Power LED is green controls are set correctly Make sure the monitor cable is connected properly to your computer Check to see if the monitor cable has bent pins Make sure the computer power is on Screen says Make sure the monitor cable is connect properly to your computer mm Check to see if the monitor cable has SEN bent pns when you turn on Make sure the computer is turned on the monitor 23 HAVING THIS PROBLEM
7. 85 1152x870 68 7 75 MAC 1280x1024 80 0 75 VESA 75 1280x1024 B User mode 91 1 85 VESA 85 In addition to factory preset modes the monitor also provides ten additional user defined modes which can be adjusted based on preset modes If the input video signal is different from our factory preset modes the new timing data will be stored automatically However the displayed parameters may need to be adjusted You may adjust the parameters using the On Screen Display as described on the previous pages 19 Automatic Power Saving If you have VESA s DPMS compliance display card or software installed in your PC the monitor can automatically reduce its power consumption when not in use If an input from a keyboard mouse or other device is detected the monitor will automatically wake up The following table shows the power consumption and signalling of this automatic power saving feature Power Management Definition VESA s mode Video H sync V sync Power Power LED used saving color ON Active Yes Yes 130W 096 Green Stand by Blanked No Yes 15W 88 5 Yellow Suspend Blanked Yes No lt 15W 88 5 Yellow OFF Blanked No No lt 5W 96 2 Amber This monitor is Energy Star compliant power management compatible larn AS AN ENERGY STAR PARTNER PHILIPS HAS DETERMINED THAT THIS PRODUCT MEETS THE ENERGY STAR GUIDELINES FOR ENERGY EFFICIENCY The pro
8. TABLE OF CONTENTS 19C5808E Getting Started Introduction Features Safety precautions and maintenance End of life disposal Installation Connection Control locations and functions OSD menu tree structure Main Controls Brightness Contrast Degauss Screen Size and Position Horizontal position Horizontal size Vertical position Vertical size Color Temperature 9300 K 6500 K 5500 K User presets IB8000E001 Ww o Noga 10 10 10 11 11 11 11 12 12 12 whe Special Controls Language Monitor status OSD controls Advanced Controls Moire Power saving Geometry Controls Pincushion Balanced pincushion Trapezoid Parallelogram Rotation Exit or Reset Additional Information Factory preset mode User mode Automatic power saving 21 22 28 26 Specifications Pin assignment Troubleshooting Glossary 18 13 18 215 15 16 16 16 16 16 16 ie IQ 19 20 Appendix English Warranty eee Al Information for user in the U S A2 Declaration FCC hae A3 Frangais Declaration FCC hae A4 Deutsch Hinweis GS ACHTUNG A5 OTHER LANGUAGE VERSIONS FRENCH FRANCAIS 27 SPANISH ESPANOL 54 Introduction The Philips Magnavox 109S color monitor displays sharp and brilliant images of text and graphics with a maximum resolution of 1600x1200 pixels It is optimal
9. The process by which metal parts of the monitor are demagnetized in order to reduce screen distortion and color impurity Geometry A set of controls that allows you to adjust the alignment of the picture on the monitor screen The goal is to square up the picture This is done by adjusting such items as balanced pincushion pincushion parallologram rotation and trapezoid Moire A fringe pattern caused by the interference between two superimposed line patterns 26
10. for Windows CAD CAM CAE desktop publishing spread sheets multi media and any other application that demands a large screen size and high resolutions The monitor automatically scans horizontal frequencies from 30KHz to 95KHz and vertical frequencies from 50Hz to 160Hz With microprocessor based digital controlled circuitry and On Screen Display OSD controls the monitor can automatically adjust itself to the video card s scanning frequency and display an image with the precise parameters you desire Features es An anti glare anti static and anti reflection high contrast screen coating eliminates any bad effects caused by room lights reflecting on and dust attracted to the screen s surface With the Color Adjustment feature you can easily choose different preset color temperatures or set your own customized color parameters The Image Tilt Adjustment feature corrects a rotated image This correction minimizes the distortions caused by elements such as the Earth s magnetic field The Green Design includes the automatic power saving function NUTEK and low emission compliance DDC1 DDC2B allows communication between the monitor and PC for optimal video configuration Moire Cancellation eliminates diffraction which is a fringe pattern in the picture Contact us at our web site http www monitors be philips com Note Your monitor operates according to the VESA DDC level 1 2B Only computers that support
11. per operation of the function requires a computer with VESA s DPMS power management capabilities When used with a computer equipped with VESA s DPMS the monitor is Energy Star compliant 20 Specifications I General CRT Screen size Viewable Image Size VIS Focusing method Dot pitch Phosphor Screen treatment Display area Factory preset Maximum usable Scanning frequency Horizontal line Vertical frame Input power Power consumption Thermal dissipation Input signal Vi ideo Sync Pedestal Tilt Swivel Physical Unit dimension WxHxD Net weight Operating conditions Temperature Humidity Storage conditions Temperature Humidity 19 48 2 cm flat amp square 17 9 Dynamic focus 0 26 mm P22 or equivalent medium short persistence ARASC 840 mm H x 255 mm V 360 mm H x 270 mm V 30 95kHz AutoScan 50 160 Hz AutoScan 100 240 V AC 10 60 50 Hz 110 Watt normal 130 Watt maximum 375 normal BTU Hr 444 maximum BTU Hr 0 7 Vpp 75 Ohm impedence Separate sync TTL level Composite sync TTL level 5 forward 11 backward 90 leftward 90 rightward 450 x 475 x 473 mm 17 7 x 18 7 x 18 6 23 kg 5 C 40 C 20 80 20 C 65 C 5 95 21 Il Pin assignment 1 The 15 pin D sub connector male of the signal cable i ae ee Red
12. the curvature of the image TRAPEZOID PARALLELOGRAM ROTATION EXIT RESET inward or outward at either the left or right side of the screen Increase or decrease the bottom part of the image in order to match the size of the top part of the image Adjust the degree to which each side of the image tilts to the right or left Rotate the total image clockwise or counterclockwise Save and exit the GEOMETRY CONTROLS settings Reset the GEOMETRY CONTROLS settings to factory defaults Exit or Reset EXIT Exit OSD menu and save all previous settings automatically When you finish all the settings you can choose EXIT RESET Reset all settings to the factory defaults RESET ALL SETTINGS NO Escape the RESET function and return to main controls menu YES Confirm the RESET function and return to main controls menu 17 mz i o hr LT A Self Test If the signal cable is disconnected if there is no signal input from the PC when the monitor power first turns on the screen will show a message as below NO SYNC INPUT Data Storage A Factory preset mode This monitor has eight factory preset modes as indicated in the following table Resolution Frequency Standard H KHz V Hz 640x400 31 5 70 VGA 640x480 31 5 60 VGA 800x600 46 9 75 VESA 75 1024x768 60 0 75 VESA 75 1024x768 68 7 85 VESA
13. the same guidelines and operate at the same or a higher level can make use of this feature If your computer does not support the relevant guidelines you can still use your monitor and computer However you may need to manually specify the appropriate resolution in the computer ENERGY STAR is a U S registered mark As an Energy Star Partner Philips has determined that this product meets the Energy Star guidelines for energy efficiency Safety precautions and maintenance Unplug the monitor if you are not going to use it for an extended period of time Unplug the monitor if you need to clean it with a slightly damp cloth Wiping the screen with a dry cloth is okay when the power is off However never use alcohol or ammonia based liquids Consult a service technician if the monitor does not operate normally when following the instructions in this manual The back cover should be removed only by qualified service personnel The top of the monitor is not a shelf Remove any object that could fall into the vents or prevent proper cooling of the monitor s electronics Keep the monitor dry To avoid electric shock do not expose it to rain or excessive moisture End of life disposal Your new monitor contains materials that can be recycled and reused Specialized companies can recycle your product to increase the amount of reusable materials and to minimize the amount to be disposed of Please find out about the local
Download Pdf Manuals
Related Search
Related Contents
Optica Operator`s Manual - GE Measurement & Control Service 3121325 03-24-11 ANSI English ビ丿レ防災設備 プラント防災設備 課警報設備 各種消火器 http=//www L.U.M. Mekfarmer 120 - v. Pflug User Manual: Model PM2110 miniCO BC OnLine Deposit Account System User's Guide for Applying DSTO-GD-0248 PR - Department of Defence 分析コスト削減応援キャンペーン展開中!! GE USM Go Operating Manual Samsung SyncMaster Copyright © All rights reserved.
Failed to retrieve file