Home

Pelco FR106011 Satellite Radio User Manual

image

Contents

1. 0 30 C2649M 9 07 Important Safety Instructions C2649M 9 07 noo fF t nm Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has wo blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus
2. BALANCED AUDIO CONNECTIONS BETWEEN DEVICE B AND FT106011 TRANSMITTER Figure 16 Balanced Audio Wiring C2649M 9 07 FR106011 RECEIVER AUDIO CONNECTOR DEVICE A AUDIO OUT LEFT AUDIO OUT RIGHT SHIELD UNBALANCED AUDIO CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSMITTER AUDIO CONNECTOR DEVICE AUDIO IN LEFT AUDIO IN UNBALANCED AUDIO CONNECTIONS BETWEEN DEVICE B AND FT106011 TRANSMITTER Figure 17 Unbalanced Audio Wiring C2649M 9 07 29 Troubleshooting LED indicators on the front panel of the FT106011 transmitter FR106011 receiver refer to Figure 2 allow you to monitor signal status laser status data activity contact closure activation and operating power Table F provides information about the front panel indicators and associated troubleshooting guidelines Table F Troubleshooting with Front Panel Indicators Indicator Color Meaning Possible Cause Corrective Action Power LED Pelco badge Blue Power is being applied o action required to the module Not lit Power is not being Power connection is Check power connection applied to the module faulty f module is rack mounted reseat module or power supply as necessary Power supply has failed Replace power supply Loss of power occurs du
3. 4 In Right 5 In Left 6 In Right 7or8 Shield 9 Out Left Out Left 10 Out Right Out Right 11 Out Left 12 Out Right C2649M 9 07 FT106011 TRANSMITTER CONTACT CLOSURE CONTACT CLOSURE IN COMMON OUTPUT CONNECTIONS BETWEEN CONTACT CLOSURE OUTPUT AND FT106011 TRANSMITTER FR106011 RECEIVER CONTACT CLOSURE CONNECTOR CONTACT CLOSURE INPUT 343 4 OUT common 245 OUT NORMALLY OPEN CONNECTIONS BETWEEN CONTACT CLOSURE INPUT AND FR106011 RECEIVER Figure 8 Normally Open Contact Closure Wiring FT106011 TRANSMITTER CONTACT CLOSURE CONNECTOR CONTACT CLOSURE IN COMMON OUTPUT CONNECTIONS BETWEEN CONTACT CLOSURE OUTPUT AND FT106011 TRANSMITTER FR106011 RECEIVER CONTACT CLOSURE CONNECTOR CONTACT CLOSURE INPUT NORMALLY CLOSED CONNECTIONS BETWEEN CONTACT CLOSURE INPUT AND FR106011 RECEIVER Figure 9 Normally Closed Contact Closure Wiring C2649M 9 07 21 2 DEVICE A RX TX GND GND FR106011 RECEIVER DATA CONNECTOR RS 232 DATA SELECTION 907 RS 232 DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER DEVICE RX TX GND GND FT106011 TRANSMITTER DATA CONNECTOR RS 232 DATA SELECTION 907
4. RS 232 DATA CONNECTIONS BETWEEN DEVIGE B AND FT106011 TRANSMITTER Figure 10 RS 232 Data Communication Wiring C2649M 9 07 C2649M 9 07 FR106011 RECE DATA CO DEVICE A VER NECTOR RS 422 DATA SELECTION 907 RS 422 DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSMITTER DEVICE B DATA CONNECTOR RS 422 DATA SELECTION RS 422 DATA CONNECTIONS BETWEEN DEVICE B AND FT106011 TRANSMITTER Figure 11 RS 422 Data Communication Wiring 23 24 FR106 011 RECEIVER DEVICE A DATA CON NECTOR RS 485 2 WIRE DATA SELECTION 907 RS 485 2 WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSM ee DATA CON TTER NECTOR RS 485 2 WIRE DATA SELECTION RS 485 2 WIRE DATA CONNECTIONS BETWEEN DEVICE B AND FT106011 TRANSMITTER Figure 12 RS 485 2 Wire Half Duplex Data Communication Wiring C2649M 9 07 FR106011 RECEIVER DATA CONNECTOR RS 485 4 WIRE DATA SELECTION TX 907 DEVICE A RS 485 4 WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSMITTER DEVICES DATA CONNECTOR RS 485 4 WIRE DATA SELECTION 907 RS 485 4 WIRE DATA CONNECTIONS BETWEEN
5. 6 pin connector removable mating connector with tension clamps not shown DATA CONNECTOR 8 pin connector removable mating connector with tension clamps not shown AUDIO CONNECTOR 12 pin connector removable mating connector with tension clamps not shown BNC CONNECTOR 75 ohm analog video input FT106011 output FR106011 For additional information about rear panel connections refer to the nstallation section C2649M 9 07 1 Installation PACKAGE CONTENTS The following items are supplied 1 1 1 FT106011 transmitter or FR106011 receiver Regulated switching power supply with four plug adapters North American Australian U K and European configurations 100 240 VAC 50 60 Hz input 12 VDC output 1 small flat tip screwdriver Wall clip with two 4 40 x 0 25 inch Phillips pan head screws with lock washers for attachment of single module to wall FT106011 FR106011 Fiber Transmitter and Receiver Installation manual this manual SETTING THE AUDIO SIGNAL AND IMPEDANCE MODE An Audio Select switch which is a 10 position rotary switch is provided on the bottom of the FT106011 transmitter and the FR106011 receiver refer to Figure 5 The Audio Select switch allows you to set the desired audio mode of operation With the FT106011 transmitter FR106011 receiver powered off set the Audio Select switch to the desired mode of operation using the supplied screwdriver Table B lists Audio Select switch settings
6. 5 Out Normally Open 6 Out Normally Closed Table D Data Connector Pin Assignments Pin RS 485 RS 485 Number RS 232 RS 422 2 Wire 4 Wire Manchester Bi Phase 1 TX Out T R Out In TX TX Out W TX 2 TX Out T R Qut In TX TX Out TX Out 3 RX In RX RX Ine W RX Int 4 RX In RX In RX In B RX In 5 RX In 6 TX Out Z 7or8 Ground Shield Shield Ground may be required based on conditions of installation Refer to the current version of EIA TIA 422 and EIA TIA 485 standards for additional information NOTES e TX Out TX TX Out T Qut and T Out denote data output from the transmitter receiver e RX In Ine RX In R In and R In denote data input to the transmitter receiver e W denotes white wire and B denotes black wire e Data ports are not terminated For RS 422 RS 485 2 Wire RS 485 4 Wire Manchester and Bi Phase data signals termination may be required based on conditions of installation If termination is required terminate the data signal at the endpoint of the data bus using a 120 ohm resistor 20 Table E Audio Connector Pin Assignments Pin Number Balanced Unbalanced 1 In Left 2 In Right 3 In Left
7. A est conforme la norme NMB 003 du Canada C2649M 9 07 Product Overview DESCRIPTION V gt AUDIO DATA gt CONTACT DEO CLOSURE FT106011 FR106011 TRANSMITTER ONE RECEIVER FIBER VIDEO d a AUDIO lt DATA The FT106011 FR106011 fiber transmitter and receiver provide simultaneous transmission of one unidirectional video channel two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure over one optical fiber refer to Figure 1 E CONTACT CLOSURE Figure 1 FT106011 FR106011 Video Audio Data and Contact Closure Transmission Features of the FT1 06011 FR10601 10 bit digitally encoded video fiber optic transmission system include the following for high quality video transmission over a single fiber Two bidirectional 24 bit digitally encoded audio channels with user selectable 600 ohm balanced or 47K ohm unbalanced input impedance Bidirectional data channel wi Manchester Bi Phase and Coaxitron communication Bidirectional contact closure Multimode fiber support for distances up to 6 km 3 7 mi Single mode fiber support for distances up to 38 km 23 6 mi Laser diode for t ransm NOTE The FT106011 with FDA radiation per 2001 08 Patent pending Compatible with ambient operating tem high line low lin NOTE Conform ransm ission of optical signals transmitter FR106011 receiver is a Cl
8. Mode Models FT1060 FR106011SSTR FT1060 FR1060 11SSTR 11SFCR 11SFCR Fiber optic video transmitter with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure single mode ST connector Fiber optic video receiver with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure single mode ST connecto Fiber optic video transmitter with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure single mode FC connector Fiber optic video receiver with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure single mode FC connector For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT106011MSTR for example is CT106011MSTR OPTIONAL ACCESSORIES The following optional accessories are available WM5001 3U Wall mount base kit for single width module WM5001 3UEXP Wall mount expansion kit for single width module RK5000 3U 19 inch rack mount chassis for 14 slots no power 3 RUs RK5000PS 3U 19 inch rack mount chassis for 12 slots with power 3 RUs EPS5000 120 External rack power supply 1 RU dual 120 W power outputs RK5001B 3U Blank filler panel single width RK5002B 3U Blank filler panel dou
9. Transmission Class 1 Transmitter Receiver Wavelength Budget Distance Limit Multimode 62 5 125 um FT106011MSTR FR106011MSTR 1310 nm 22 dB 6 km 3 7 mif 15 6 mW 850 nm 22 dB 6km 3 7 mi 0 78 mW Single Mode 9 125 FT106011SSTR FR106011SSTR 1310 nm 24 dB 38 km 23 6 mi 15 6 mW 1550 nm 24 dB 38 km 23 6 mi 10 0 mW FT106011SFCR FR106011SFCR 1310 nm 24 dB 38 km 23 6 mi 15 6 mW 1550 nm 24 dB 38 km 23 6 10 0 mW The FT106011 transmitter FR106011 receiver is classified by the FDA as a Class 1 laser product When using 50 125 um multimode fiber subtract 3 dB from the optical power budget C2649M 9 07 Green 2649 9 07 The materials used the manufacture of this document and its components compliant the reguirements of Directive 2002 95 EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment 37 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on fiber optic products and TW3000 Series unshielded twisted p
10. Transmitter and FR106011 Receiver 11 As SN dio SelecboWItGhio deese re mod E 13 5 Bata Select Switch ac Ist dade hadi oe e Ec idet 15 6 Mounting the FT106011 Transmitter FR106011 Receiver Using the Wall Clip 17 7 106011 Transmitter FR106011 Receiver Connections 19 8 Normally Open Contact Closure Wiring 21 9 Normally Closed Contact Closure 21 10 RS 232 Data Communication Wiring 22 1 RS 422 Data Communication Wiring 23 12 RS 485 2 Wire Half Duplex Data Communication Wiring 24 3 RS 485 4 Wire Full Duplex Data Communication Wiring 25 14 Manchester Data Communication Wiring 26 5 Bi Phase Data Communication Wiring 27 6 Balanced Audio Wiring 28 17 Unbalanced Audio Wiring FY Y Lad 29 C2649M 9 07 3 List of Tables A Audio Select Switch Settings ee aa role eae et ep RE A 13 B Data Select Switch Settings sts tony ien ccc Y Y YF cece cece Y YY ud 15 C Contact Closure Pin Assignments 19 D Data Connector Pin Assignments 20 E Audio Connector Pin Assignments 20 F Troubleshooting with Front Panel Indicators
11. and associated audio modes of operation as indicated on the bottom of the units NOTE If you wish to change the audio mode after the FT106011 transmitter FR106011 receiver has been powered on power off the transmitter receiver change the audio mode and then power on the transmitter receiver again C2649M 9 07 AUDIO SELECT SWITCH 907 AUDIO DATA SELECT SELECT 0 UNBAL47KO 0 RS 232 1 BAL 6000 1 RS 422 2 RS 485 2W 3 RS 485 4W 4 Man Bi Phase 5 Coaxitron 6 9 NOT USED 2 9 NOT USED Power Standalone Power COMPLIES WITH FDA RADIATION PERFORMANCE STANDARD 21 CFR SUBCHAPTER C CLASS 1 LASER PRODUCT Figure 4 Audio Select Switch Table A Audio Select Switch Settings Switch Setting Audio Mode O default setting UNBAL 47K 9 Unbalanced audio signals 47K ohm input impedance 1 BAL 600 O Balanced audio signals 600 ohm input impedance NOTE Switch settings 2 9 are not used If switch setting 2 9 is selected the Audio Present LED lights red C2649M 9 07 SETTING THE DATA COMMUNICATION MODE A Data Select switch which is a 10 position rotary switch is provided on the bottom of the FT106011 transmitter and the FR106011 receiver refer to Figure 5 The Data Select switch allows you to set the data communication mode reguired for the transfer of data With the FT10
12. has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Unless the unit is specifically marked as a NEMA Type 3 35 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Use only installation methods and materials capable of supporting four times the maximum specified load A CCC approved power cord must be used to power this equipment when used in China CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are gualified to do so The product and or manual may bear the following marks A This symbol indicates that dangerous voltage constituting a risk of electric shock is present CAUTION within this unit RISK OF ELECTRIC SHOCK DO NOT OPEN This symbol indicates t
13. using the optional external power he RK5000PS 3U RK5000 3U Fiber Rack Mount Chassis modate Endura modules but can also accommodate fiber 5001 1UEXP adapter kit The RK5001 1UEXP adapter kit 06011 transmitter FR106011 receiver into the e RK5000PS 5U chassis refer to the RK5000PS 5U Rack Mount Chassis MOUNTING THE TRANSMITTER RECEIVER TO A WALL The FT106011 transmitter FR1060 Using the supplied wall clip 1 receiver can be mounted to a wall in the following ways or attachment of a single module to a wall For installation instructions refer to the Mounting the Transmitter Receiver Using the Wall Clip section Using he optional WM5001 The WM5001 3UEXP expansion kit allows mounting of an additional recommended that a maximum of three expansion kits be used with maximum of four single wid NOTE The WM5001 wall m designed for mounting of do and double width modules is desired it is recommended that a maximum of two single width modules and one double width module be mounted in combination with one another h modules to be mounted to the wall wall mount kits which are designed for mounting of single width fiber optic modules The WM5001 3U base kit allows mounting of a s ingle module to the wall module It is he base kit allowing a ount kits can be used with the WM5002 wall mount kits which are uble width fiber optic modules If mounti ng a mix of single width For mounting instructions using
14. 601 reguired dat 1 transmitter FR106011 receiver powered off set the Data Select switch to the a communication mode using the supplied screwdriver Table B lists Data Mode Select switch settings and associated data communication modes as indicated on the bottom of the units Note the following e FT106011 transmitter and the FR106011 receiver allow data translation between RS 232 and RS 422 signal levels Consequently the Data Select switch can be set to 0 RS 232 on the transmitter and to 1 RS 422 on the receiver Conversely the Data Select switch can be set to 1 RS 422 on the transmitter and to 0 RS 232 on the receiver fyou wish to change the data communication mode setting after the FT106011 transmitter FR1060 communication mode setting and 11 receiver has been powered on power off the transmitter receiver change the data then power on the transmitter receiver again C2649M 9 07 C2649M 9 07 DATA SELECT SWITCH AUDIO DATA SELECT SELECT 0 UNBAL 47KQ 0 RS 232 1 BAL 600Q 1 RS 422 2 9 NOT USED 2 RS 485 3 RS 485 9 Rack Power 7 A iii ower 4 Man Bi 5 Coaxitron 6 9 NOT USED lem 2w 4w Phase COMPLIES WITH FDA RADIATION Eccc STANDARD 21 CFR SUBCHAPTER CLASS 1 LASER Figure 5 Data Select Switch Table B Data Select Switch Setti
15. DEVIGE B AND FT106011 TRANSMITTER Figure 13 RS 485 4 Wire Full Duplex Data Communication Wiring C2649M 9 07 25 26 DEVICE A FR106011 RECEIVER DATA CONNECTOR MANCHESTER DATA SELECTION MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER DATA CONNECTOR FT106011 SMITTER MANCHESTER DATA SELECTION 907 MANCHESTER DATA CONNECTIONS BETWEEN DEVIGE B AND FT106011 TRANSMITTER W DENOTES WHITE WIRE AND B DENOTES BLACK WIRE Figure 14 Manchester Data Communication Wiring C2649M 9 07 C2649M 9 07 FR106011 RECEIVER ae DATA CONNECTOR BI PHASE DATA SELECTION 907 BI PHASE DATA CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSMITTER DEVICE DATA CONNECTOR BI PHASE DATA SELECTION TX 9 0 7 BI PHASE DATA CONNECTIONS BETWEEN DEVICE B AND FT106011 TRANSMITTER Figure 15 Bi Phase Data Communication Wiring 27 28 FR106011 RECEIVER AUDIO CONNECTOR DEVICE A AUDIO 0UT LEFT AUDIO 0UT RIGHT BALANCED AUDIO CONNECTIONS BETWEEN DEVICE A AND FR106011 RECEIVER FT106011 TRANSM TTER AUDIO CONNECTOR DEVICE B AUDIO IN LEFT AUDIO IN RIGHT
16. INSTALLATION FT106011 FR106011 Fiber Transmitter and Receiver Video with Bidirectional Audio Data and Contact Closure C2649M 9 07 Contents Important Safety Instructions Y Y ud 5 Regulat ry Notices LL y YL YF DYLET 7 Product 2 LO DD GL FO 8 DGSCHDUOR RP 8 Models edn hac add enda tee lalla gy GAM 9 Optional ACCessorie8 eem ee eth qu amen WDD Y YR 9 Front Panel Senes tue He ae oT OR E ERES Joa Ls sn Anis 10 Rear Panels ec a re EE e eg t e ee ees 11 Installation is o YN gt 12 Package Contents aa prises kafe st Gea et cael wae RESP ons 12 Setting the Audio Signal and Impedance Mode 12 Setting the Data Communication Mode 14 Mounting the Transmitter Receiver 16 Mounting the Transmitter Receiver into a Rack 16 Mounting the Transmitter Receiver to a Wall 16 Connecting the 18 Troubleshootinigo tede dn serer y aiid Vee del ES 30 NW xc au NW dd FD Fd dn YN WU 35 List of lllustrations 1 FT106011 FR106011 Video Audio Data and Contact Closure Transmission 8 2 Front Panel of FT106011 Transmitter and FR106011 Receiver 10 3 Rear Panel of FT106011
17. air transmission products Three years on Spectra IV products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Three years on PMCL200 300 400 Series LCD monitors Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra III Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video oducts e year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of P
18. as a stand alone module A 12 VDC power supply is provided If a 24 VAC power supply is used the power supply must be a Listed Direct Plug In Power Unit marked as Class 2 and rated as 24 VAC 200 mA minimum output _ n extreme temperature conditions it is recommended that an industrial rated outdoor power supply be used e Fiber connection Contact closure connection e Data connection e Audio connection e Video input connection transmitter only e Video output connection receiver only 18 C2649M 9 07 C2649M 9 07 POWER ALARM CONNECTION FOR RACK MOUNTED MODULE POWER CONNECTION FOR STANDALONE MODULE FIBER OPTIC CABLE CONTACT CLOSURE DATA AND AUDIO COMMUNICATIONS CABLES REFER TO TABLES C D AND E FOR CONNECTOR PIN ASSIGNMENTS AND TO FIGURES 8 17 FOR WIRING DIAGRAMS COAXIAL CABLE TO INSERT OR REMOVE A WIRE DO THE FOLLOWING 1 USING THE SUPPLIED SCREWDRIVER PRESS DOWN ON THE APPROPRIATE CLAMP UNTIL THE SCREWDRIVER IS FIRMLY SEATED IN THE SLOT 2 INSERT THE WIRE INTO OR REMOVE THE WIRE FROM THE ASSOCIATED PIN 3 REMOVE THE SCREWDRIVER Figure 7 FT106011 Transmitter FR106011 Receiver Connections Table C Contact Closure Pin Assignments Pin Number Contact Closure CC 1 In Common 2 In 3 or4 Out Common
19. ass 1 ission technology allowing Coaxitron contro NTSC PAL and SECAM video standards Designed to meet NEMA TS 2 and Caltrans traffic signal control e above 95 percen al coating is required for operation in environmen t condensing No performance adjustments required 12 VDC or 24 VAC power supply Stand alone and rack mountable modular design ormance standard 21CFR Subchapter J and with IEC 60825 1 Edition h user selectable RS 232 RS 422 RS 485 2 wire 4 wire at full distance capabil quipment standards for aser product that compli hat allows a choice of normally open or normally closed outputs e 1 2 ities perature mechanical shock and vibration humidity with condensati e voltage conditions and transient voltage protection LED indicators for monitoring of signal status laser status data activity contact closure activation and operating power on ts with relative humidity C2649M 9 07 MODELS The FT106011 FR106011 fiber transmitter and receiver consist of the following series of models Multimode Models FT106011MSTR FR106011MSTR Fiber optic video transmitter with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure multimode ST connector Fiber optic video receiver with two bidirectional audio channels one bidirectional data channel and one bidirectional contact closure multimode ST connector Single
20. ble width RK5001 1UEXP Adapter kit that allows a 3 RU single width fiber module to be used in C2649M 9 07 RK5000PS 5U rack mount chassis FRONT PANEL The front panel of the FT106011 transmitter and FR106011 receiver provides LED indicators that allow you to monitor contact closure activation audio signal status data activity video signal status optical signal laser status and operating power refer to Figure 2 FT106011 FR106011 TRANSMITTER RECEIVER Figure 2 Front Panel of FT106011 Transmitter and FR106011 Receiver CONTACT CLOSURE LED AUDIO PRESENT LED DATA ACTIVITY LED VIDEO PRESENT LED 00000 OPTIG FAULT LED optical signal status laser status indicator o POWER LED Pelco badge For additional information about the front panel LEDs refer to the Troubleshooting section 10 C2649M 9 07 REAR PANEL All connections to the FT106011 transmitter and FR106011 receiver are made to the rear panel of the modules refer to Figure 3 Figure 3 Rear Panel of FT106011 Transmitter and FR106011 Receiver RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STAND ALONE POWER CONNECTOR 2 pin connector for power connection of stand alone module removable mating connector with screw terminals not shown FIBER OPTIC CONNECTOR ST or FC dependent on FT106011 FR106011 model CONTACT CLOSURE CONNECTOR
21. e C2649M 9 07 Continued on next page 31 Table F Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Data Activity LED 1010 Flashing amber Data is being trans mitted onto the fiber by he data port or is being received from No action reguired he fiber by the data port Red The Data Select switch The Data Select switch is Ensure that the Data Select is set to an invalid set to position 6 7 8 switch is set to the correct position or 9 position refer to the Setting the Data Communication Mode section for detailed information Not lit Data is not being Data is not present on No action required transmitted onto the the channel fiber by the data port or Data connection is faulty Check data connections is not being received ANO from the fiber by the Data communication Replace cable data port cable is defective Continued on next page 32 C2649M 9 07 Table F Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Video Present LED 09 Green Red on transmitter Incoming video signal is present on the channel Incoming video signal is not present on the channel Video source is not powered on Video source is not connected to the transmitter No action reguired Check power connec
22. e Check circuit breaker s to tripped circuit use s or electrical service breaker s blown fuse s as necessary or faulty electrical service Contact Closure LED CC Amber Contact is closed No action reguired Not lit Contact is open No action reguired Connections are faulty Check connections Continued on next page 30 C2649M 9 07 Table F Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Green Red Audio Present LED C1 Audio is being trans mitted onto the fiber by the audio port or is being received from the fiber by the audio port The Audio Select switch is set to an invalid position The Audio Select switch is set to any of the following positions 2 3 4 5 6 7 8 or 9 No action required Ensure that the Audio Select switch is set to position O or 1 as desired refer to the Setting the Audio Signal and Impedance Mode section for detailed information Intermittent red An audio overload condition exists The audio input level exceeds 3 0 Vp p Lower the audio input level Not lit Audio is not being transmitted onto the fiber by the data port or is not being received from the fiber by the data port Audio is not present on the channel No action required Audio connection is faulty Check audio connections Cable is defective Replace cabl
23. elco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products hall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential amages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state o state a warranty repair is reguired the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Model and serial number 2 Date of shipment number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanatio
24. f the fiber optic link If the losses do exceed the optical power budget contact Product Support Flashing red Laser has shut down Fiber module is operating Ensure that fiber module in extreme conditions for operates according to example operating operating conditions stated emperature is below or in the Specifications above recommended section and then cycle the ange as stated in the the power If problem persists Specifications section contact Product Support Laser has reached end of Cycle the power If problem life persists contact Product Support 34 C2649M 9 07 Specifications VIDEO Number of Channels Modulation Type Video Input FT106011 Video Output FR10601 1 Bandwidth Gain Differential Gain Differential Phase Tilt Signal to Noise Ratio AUDIO Number of Channels Audio Input FT106011 Audio Qutput FR106011 Input Impedance Input Output Connection Bandwidth Total Harmonic Distortion Signal to Noise Ratio DATA Number of Channels Data Communication Maximum Baud Rate o ONTACT CLOSURE umber of Channels Input Output 2 GENERAL Operating Temperature Input Power Reguirements LED Indicators C2649M 9 07 1 Pulse code modulation 10 bit resolution 1 0 Vp p 75 ohms NTSC PAL and SECAM 6 5 MHz Unity lt 1 lt 0 7 lt 1 gt 70 dB CCIR weighted 2 2 9 Vp p maximum 600 ohms or 47K ohms switch selectable Balanced 600 ohms
25. hat there are important operating and maintenance instructions in the literature accompanying this unit C2649M 9 07 Regulatory Notices This devi ce complies wi conditions 1 this devic interfere nce received in h Part 15 of the FCC Rules Operation is subject to the following two e may not cause harmful interference and 2 this device must accept any cluding interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This egui pursuant pment has bee n tested and found to comply with the limits of a Class A digital device to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment This eguipme accordance with the ins Operation of this eguipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense nt generates uses and can radiate radio freguency energy and if not installed and used in ruction manual may cause harmful interference to radio communications Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe
26. n with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C2649M 9 07 Original version Pelco the Pelco logo Camclosure Esprit Genex Legacy Coaxitron and Spec
27. ngs Switch Setting Data Communication Mode 0 default setting RS 232 RS 422 RS 485 2 Wire RS 485 4 Wire Manchester Bi Phase ony BS w ry gt Coaxitron NOTE Switch settings setting 6 9 is selected 6 9 are not used If switch he Data Activity LED lights red MOUNTING THE TRANSMITTER RECEIVER The FT106011 transmitter FR106011 receiver can be mounted into a rack or can be used as a stand alone module As a stand alone module the unit can be placed on a desktop or can be mounted to a wall MOUNTING THE TRANSMITTER RECEIVER INTO A RACK The FT106011 transmitter FR106011 receiver can be installed into an RK5000 Series rack mount chassis which can be mounted into an in RK5000 Series rack mount chassis includes the following models RK5000PS 3U and RK5000 3U Designed to accommodate fiber optic modules as follows RK5000PS 3U rack moun dustry standard 19 inch 48 26 cm eguipment rack The chassis provides 12 module slots and a power supply RK5000 3U rack mount chassis provides 14 module slots a power supply is not For additional informati nstallation manual optic modules with the is reguired for installati RK5000PS 5U chassis ncluded Power to the modu supply EPS5000 120 RK5000PS 5U Designed to accom on refer to use of the R on of the FT For information about th nstallation manual es can be supplied
28. or unbalanced 47K ohms 20 kHz lt 0 02 gt 87 dB 1 RS 232 RS 422 RS 485 2 wire 4 wire Manchester Bi Phase Coaxitron 500 kbps 1 Active low 30 VDC 1 A maximum Choice of normally open or normally closed 40 to 1679F 40 to 75 C 12 VDC or 24 VAC 350 mA Power Video Present Audio Present Data Activity Contact Closure Activation Optic Fault 35 Dimensions Unit Weight MECHANICAL Connectors Rack Power Al Stand Alone Power Video Audio Data Contact Closure Fiber Optic 8 75 D x 1 08 W x 4 81 22 23 x 2 74 x 12 22 cm 1 6 Ib 0 73 kg arm 4 pin connector 2 pin connector screw terminals BNC 12 pin connector tension clamps 8 pin connector tension clamps ST for multimode fib ST or FC for single mode fiber 6 pin connector tension clamps er OPTICAL POWER BUDGET TRANSMISSION DISTANCE AND LASER CLASS 1 LIMIT t Maximum tran S Maximum tran connector and NOTES smission distance is limited by fiber bandwidth smission distance is based on attenuation of 0 5 dB km plus a 5 dB buffer for splice losses e For conform al coated models replace the first letter F in the model number with the letter The conformal coated version of FT106011MSTR for example is CT106011MSTR e For models with higher optical power budgets contact the factory Optical Maximum Laser Compatible Power
29. the wall mount kits refer to the WM5000 Series Wall Mount Kit Installation manual C2649M 9 07 Mounting the Transmitter Receiver Using the Wall Clip NOTE Before mounting the FT106011 transmitter FR106011 receiver to a wall ensure that there is adeguate space at both ends for viewing the front panel LEDs and for making the various rear panel cable connections To attach the FT106011 transmitter FR106011 receiver to a wall using the supplied wall clip refer to Figure 6 and do the following 1 Using the two vertical or horizontal wall mounting holes attach the wall clip to a wall using two screws not provided 2 Slide the module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip 3 Attach the module to the clip using the two Phillips pan head screws provided for the clip MOUNTING HOLE 2 S HORIZONTAL MOUNTING HOLE 2 LOWER SCREW PHILLIPS gt FLANGE PAN HEAD WITH WALLCLIP LOCK WASHER 2 amp Figure 6 Mounting the FT106011 Transmitter FR106011 Receiver Using the Wall Clip C2649M 9 07 17 CONNECTING THE TRANSMITTER RECEIVER Connections to the FT106011 transmitter and the FR106011 receiver are made on the rear panel of the modules refer to Figure 7 and consist of the following e Power connection NOTES A12VDC or 24 VAC power supply can be used to power the transmitter receiver when used
30. tion to the video source Check BNC connections Coaxial cable is defective Replace cable Red on receiver Incoming video signal is not present on the channel Optical signal is not being received from the transmitter Optic Fault LED is also red Refer to the Optic Fault LED section in this table Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Coaxial cable connected to the transmitter is defective Check BNC connections Replace cable C2649M 9 07 Continued on next page 3 Table F Troubleshooting with Front Panel Indicators Continued Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED O Green The optical signal is No action reguired being received and laser is operating properly Red The optical signal is Remote fiber module is Check power connections not being received not powered on Replace power supply if necessary Fiber optic cable is not Check fiber optic connected connections Fiber optic cable Clean polish or replace connectors are dirty or fiber optic cable are damaged connectors as necessary Fiber optic cable is Replace cable defective A problem exists with Verify that losses in fiber he optical power optic cable do not exceed budget the optical power budget specification o
31. tra are registered trademarks of Pelco Endura ExSite and Spectra lll are trademarks of Pelco Copyright 2007 Pelco DLP is a registered trademark of Texas Instruments Inc All rights reserved PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung  Upgrade Toolkit - Oracle Documentation  Manual de Instrução  取扱説明書  DeLOCK USB 2.0 Card Reader micro SD/micro SDHC  TESTING THERMAL IMAGERS - Practical Guide  Whirlpool Roper RT14BKXJW00 User's Manual  Worldwide Lighting W83330B13 Instructions / Assembly  Samsung 731BF Brugervejledning  Guide des études Licence 2 - Université du Littoral Côte d`Opale  

Copyright © All rights reserved.
Failed to retrieve file