1. PELCO PS20 Medium Duty Indoor Outdoor Scanner Installation Operation Manual C361M A 8 02 Pelco World Headquarters 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product the following WARNINGS should be observed 1 Installation and servicing should only be done by qualified service personnel and conform to all local codes 2 Installation shall be done in accordance with all local and national elecctrical and mechanical codes using only approved materials 3 Unless the unit is specifically marked as a NEMA Type 3 3R 3S 4 4X 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture 4 The camera and lens combined weight shall not exceed 35 pounds 16 kg 5 Only use replacement parts recommended by Pelco 6 After replacement repair of this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry 7 Use only installation methods and materials capable of supporting four times the combined weight of the enclosure scanner camera and lens 8 AnALL POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be incorporated in t
2. NOT USED NOT USED WITHOUT CONTROLLER 24 AC LO GROUND 24 AC HI NOT USED NOT USED RANDOM MODE 120 AC LO GROUND 120 AC HI t 24 AC HI GLAND AND WIRING ATTACHMENT Figure 2 Bottom View Wire Attachment 230V MODEL WITH CONTROLLER CABLE FROM SCANNER WITHOUT CONTROLLER BLU 230 AC LO GROUND 230 AC HI CABLE FROM SCANNER NOT USED NOT USED RANDOM MODE 230 AC LO 1 GROUND 1 230 AC HI SCANNER 00815 Figure 3 Wiring Diagrams 120V 24V and 230V Models Table A Maximum Operating Distances Model 20 AWG 18 AWG 16 AWG 0 5 mm 1 0 mm 1 5mm PS20 2 300 ft 3 700 ft 5 900 ft 701 m 1 127 m 1 798 m PS20 24 5 600 ft 9 000 ft 14 300 ft 1 706 m 2 743 m 4 368 m PS20 23 1 400 ft 2 300 ft 3 600 ft 426 m 701 m 1 097 m Pelco Manual C361M A 8 02 MOUNTING Attach the scanner to a flat surface or compatible wall ceiling pedestal mount using four bolts not provided CAMERA ENCLOSURE MOUNTING 1 Center balance the camera and lens or enclosure camera and lens load on the tilt table Adjust the positioning as needed to align the mounting holes 2 Attach the camera or enclosure to the tilt table with two 1 4 20 hex head bolts not supplied 3 Position the tilt table at the desired angle and tighten the manual tilt adjustment bolts refer to Figure 3 to secure the table 4
3. Make all camera enclosure and lens connections Refer to the manuals supplied with the equipment Leave enough slack in the cable wiring so that the camera enclosure and lens connections do not interfere with the operation of the scanner SPEED SETTING The PS20 Series scanner has selectable speed settings for 3 degrees 6 degrees and 12 degrees per second The default speed setting is 6 degrees per second To decrease or increase the speed setting do the following 1 Loosen the screw that secures the speed setting cover The cover is located on the side of the scanner refer to Figure 3 2 Remove the speed setting cover 3 Set the switch to the desired speed setting 4 Replace the cover and tighten the screw TILT TABLE MANUAL TILT ADJUSTMENT BOLT SETTINGS LIMIT STOP mere Figure 4 Scanner Adjustments and Settings Pelco Manual C361M A 8 02 5 LIMIT STOP ADJUSTMENT To set pan limit stops perform the following steps 1 Loosen the right and left limit stops 2 Operate the scanner Pan the unit to the right until the desired right pan limit is reached 3 Move the right limit stop to the selected position and secure in place 4 Pan the unit to the desired left position Slide the left limit stop to the selected position and secure in place 5 Pan left and right to both limit stops to check for exact positioning Tighten both stops securely To pan the scanner 380 degrees remove one limit
4. stop from the scanner Only one limit stop is removable The other limit stop is fixed to the scanner it can be adjusted but not removed Pelco Manual C361M A 8 02 SPECIFICATIONS Pelco Manual C361M A 8 02 MECHANICAL Pan Speed Maximum Load Operation Bearings Overload Protection ELECTRICAL Input Voltage PS20 PS20 24 PS20 230 Power Requirements PS20 PS20 24 PS20 230 Connectors Motors Limit Switches Conductors GENERAL Construction Finish Environment Unit Weight 0 380 movement in horizontal plane 3 6 or 12 per sec 5 35 Ib 16 kg centered Upright or inverted Heavy duty ball bearings Thermal protected 120 VAC 24 VAC 230 VAC 0 175 A 20 vA 0 600 A 15 vA 0 130 A 30 vA Wire nuts provided Stepper motor continuous duty instantaneous reversing Auto scan switching external adjustment 7 unshielded functions left right auto common safety ground AC Line AC Neutral Aluminum Gray polyester powder coat Indoor outdoor 10 to 120 F 23 to 49 C 9 9 Ib 4 5 kg REGULATORY NOTICES This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acco
5. anual C361M A 8 02 PREPARE MOUNTING SURFACE NOTE Minimum recom 1 Determine the mounting location Make sure the mounting surface can support four mendation for mounting times the combined weight of the scanner and the camera and lens or enclosure hardware Is 1 4 20 X 5 8 Hex camera and lens Refer to the manuals for your enclosure camera and lens for the Head Bolt Stainless Steel weights of those units 1 4 Split Lock Washer Stain less Steel and 1 4 Flat 2 If mounting directly to a flat surface use Figure 1 as a template and mark the bolt and cable wire feedthrough positions onto the installation surface Prepare the mounting surface and pull cable wiring for the scanner Washer Stainless Steel with 7 Outer Diameter l l l PEPEE PN a neenenenenees emsss sssssssss Figure 1 PS20 Surface Mount Template Pelco Manual C361M A 8 02 3 120V MODEL WITH CONTROLLER CABLE FROM SCANNER WITHOUT CONTROLLER WHT CABLE FROM SCANNER RANDOM MODE SCANNER WIRING Make electrical connections as required for scanner operation If required use the wire nuts provided Cable distances should not exceed the distances specified in Table A Refer to the following wiring diagrams Figure 3 and select the correct diagram for your installation 24V MODEL WITH CONTROLLER CABLE FROM SCANNER 120AC LO WHT GROUND 120 AC HI FROM SCANNER
6. ate Consignee American Overseas Air Freight Pelco 320 Beach Road 3500 Pelco Way Burlingame CA 94010 Clovis CA 93612 5699 USA USA REVISION HISTORY Manual Date C361M 6 01 C361M A 8 02 Comments Original version Revised installation instructions Added certifications Pelco the Pelco logo Spectra Genex Esprit Camclosure and Legacy are registered trademarks of Pelco Copyright 2002 Pelco All rights reserved 8 Pelco Manual C361M A 8 02
7. he electrical installation of the building 9 For 24 VAC models only use a UL Listed Class 2 power source DESCRIPTION The PS20 Series scanner is a medium duty indoor outdoor unit designed to operate with a maximum load of 35 pounds 16 kg The scanner features stepper motor technology three selectable speed settings easy to adjust limit stops and pan rotation of 380 degrees The PS20 scanner is capable of continuous and random operation when connected directly to a power source If a Pelco MPTAZ Series control is used the scanner can operate continuously randomly and manually MODELS PS20 Medium duty scanner 120 VAC PS20 24 Medium duty scanner 24 VAC PS20 230 Medium duty scanner 230 VAC INSTALLATION NOTE A terminal box or The PS20 scanner can be mounted to any flat surface in an upright or inverted position If compartment shall be pro the scanner is to be attached to a wall ceiling pedestal mount follow the instructions Vided in which mains supply provided with the mount connections are to be made s f I and shall be such that these Installation requires a mounting surface or mount with a center feed through hole Use a suitable wiring compartment terminal box for connection with the AC mains supply and connections are capable of x attach the PS20 scanner directly to the mounting surface being readily made and in spected without disturbing the wiring or the apparatus after the unit is installed 2 Pelco M
8. hen used in continuous motion applications Two years on Esprit and WW5700 series window wiper excluding wiper blades Eighteen months on DX Series digital video recorders One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additi
9. onal rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization num ber CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RAnumber and freight should be prepaid Ship to the appropriate address below f you are located within the continental U S Alaska Hawaii or Puerto Rico Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 f you are located outside the continental U S Alaska Hawaii or Puerto Rico Intermediate Consignee Ultim
10. rdance with the instructions may cause harmful interference to radio communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the re ceiver is connected Consult the dealer or an experienced radio TV technician for help WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Ex ceptions to this warranty are as noted below Five years on Pelco manufactured cameras CC3500 CC3600 CC3700 and MC3500 MC3600 MC3700 Series two years on all other cameras Three years on Genex Series multiplexers server and keyboard Two years on cameras and all standard motorized or fixed focal length lenses Two years on Legacy Camclosure Camera Systems CM6700 CM6800 CM8500 CM9500 CM9740 CM9760 Matrix DF5 and DF8 Series Fixed Dome products Two years on Spectra Esprit and PS20 Scanners including w