Home

Pelco C1445M-E (2/09) Webcam User Manual

image

Contents

1. 6 or 6P enclosure it is designed for indoor use only and it must not be installed where exposed to rain and moisture Only use replacement parts recommended by Pelco After replaceme nt repair of this unit s electrical components conduct a resistance measurement between the line and exposed parts to verify the exposed parts have not been connected to the line circuitry C1445M E 2 09 Description The PSKIT8100 pressure sensor is designed for use with the EH8100 Series enclosure The sensor ensures that enclosure pressure stays at an acceptable operation level The PSKIT8100 provides contact closure when the internal pressure of the enclosure falls below the required 5 psi Installation ENCLOSURE DISASSEMBLY 1 Disconnect power to the enclosure 2 Remove the ground wire from the ground stud on the back of the enclosure 3 Remove the electrical connector from the rear of the enclosure Turn the outer ring counterclockwise and pull off the mating portion of the connector 4 You may remove the enclosure from its mount to make the installation process easier 5 Remove the cap from the Schrader valve refer to Figure 1 6 Relieve internal enclosure pressure by depressing the center stem of the Schrader valve WARNING Pressure must be released prior to opening the enclosure or personal injury may result 7 Remove the rear plate of the enclosure refer to Figure 1 and perform the following steps a Use a screwd
2. III Spectra Mini Spectra Mini IP Esprit ExSite and PS20 scanners including when used in continuous motion applications Esprit Ti and TI2500 Series thermal imaging products Esprit and WW5700 Series window wiper excluding wiper blades M6700 CM6800 CM9700 Series matrix igital Light Processing DLP displays except lamp and color wheel The lamp and color wheel will be covered for a period of 90 days he air filter is not covered under warranty ntelli M elDC controllers e One year Video cassette recorders VCRs except video heads Video heads will be covered for a period of six months e Six months All pan and tilts scanners or preset lenses used in continuous motion applications preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty l l 992 Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to P
3. INSTALLATION by Schneider Electric PSKIT8100 Pressure Sensor Option For EH8100 Series Pressurized Camera Enclosure C1445M E 2 09 Contents Important Safety lnstr ctions oii as ade she Descriptions aan een ea a I real Enclosure Disassembly soci 20c eseeeee carta ann her a ia Pressure Sensor Installation 000 0 cent e nt ene e nent e ne Enclosure Reassembly and Recharging 000 0 c cece ccc cece cence een tence eens Reassembly ici nu ee aeaa lait hema tar aden he ante ba al nat Recharging Laada seien Sala heke bee Sagara tates ind Power CONNECT A in List of Illustrations 1 EH8100 Series Enclosure Rear View 0 0 0 0 e cence een eee 2 EH8100 Series Enclosure Rear Plate Inside View 22 00000 cece cece eee 3 EH8100 Series Enclosure Wiring Diagram 0 0 0 0 0 c ccc e cece cece eee e es C1445M E 2 09 Important Safety Instructions EY 0 69 TS Read these inst Keep these inst uctions uctions Heed all warnings Follow all instructions Refer all servic damaged in any objects have fal ng to qualified service personnel Servicing is required when the apparatus has been way such as power supply cord or plug is damaged liquid has been spilled or en into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped t Unless the un s specifically marked as a NEMA Type 3 3R 3S 4 4X
4. PP ZOOM PP FOCUS PP COM PP 5V LENS IRIS o FOCUS Figure 3 EH8100 Series Enclosure Wiring Diagram NOTES e Consult the C1420M manual section dealing with model number listings for the wattage and number of heaters for the particular model that you are using e Terminal block only on the EH8106 The EH8104 does not have a terminal block for lens presets Table A Pin Numbers and Descriptions PIN NO FUNCTION COLOR PIN NO FUNCTION COLOR A VIDEO COAX CORE J PS SWITCH WHT GRN B VIDEO COAX SHIELD K IRIS BRN E PP 5V BLK WHT L FOCUS RED D PP COM RED WHT M ZOOM ORG E CAMERA AC LINE BLU N LENS COM YEL F CAMERA AC NEUT VIO P AC NEUTRAL WHT G PS SWITCH GRN WHT R PP FOCUS YEL WHT H AC LINE BLK S PP ZOOM GRY WHT C1445M E 2 09 Enclosure Reassembly and Recharging REASSEMBLY When the enclosure is disassembled it should be recharged after reassembly and prior to installation Recharging requires the use of a Pelco EH8000RKIT recharge kit or equivalent and applicable O ring kit part EH80040RKIT or EH80060RKIT To prepare the enclosure for recharging 1 4 Once the enclosure has been disassembled remove the O ring from the rear plate and install anew O ring in the O ring groove After installing the new O ring smear a liberal amount of O ring lubricant supplied on the exterior surfac
5. e of the O ring and rear plate Replace the desiccant bag in the enclosure with the new one supplied Slide the camera sled back into the body making sure the front lip of the sled is under the retaining bracket of the enclosure When fully installed the rear plate will fit firmly into the rear opening of the housing and the retaining grove will be fully visible Reinstall the spiral retaining ring in the grove in the rear of the enclosure RECHARGING 1 Pressurize the inside of the enclosure using the EH8000RKIT recharge kit Connect the regulator to the tank by threading the nut into the socket of the tank valve Tighten with a wrench This regulator is factory preset for 12 psi 83 kPa Once the regulator has been secured to the tank open the regulator valve first and then the tank value Remove the Schrader valve cap refer to Figure 1 on page 5 Affix the self holding tire chuck to the Schrader valve To reduce the purge time necessary to remove oxygen from the enclosure position it so that the window is pointing up Remove the plastic cap on the pressure relief valve on the rear of the enclosure Use a small screwdriver to hold the valve open Allow the nitrogen to flow through the enclosure until the humidity indicator registers the lowest humidity level changing color from pink to blue The humidity indicator can be viewed through the front window of the enclosure by looking at the inside top of the enclosure Once
6. elco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number sales order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS To expedite parts returned for repair or credit please call Pelco at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair and designated return location All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assig
7. ned CA or RA number and freight should be prepaid 12 23 08 Green The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002 95 EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment PELLO by Schneider Electric www pelco com Pelco Inc Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120
8. river to pry the end of the spiral retaining ring from the retaining ring groove b Pull on the T handle to remove the rear plate from the housing SCHRADER RETAINING SPRING PRESSURE END X RELIEF VALVE GROUND STUD SPIRAL RETAINING SPRING Figure 1 EH8100 Series Enclosure Rear View C1445M E 2 09 5 Pressure Sensor Installation To install the pressure sensor 1 Remove the screw located inside the top portion of the enclosure s rear plate refer to Figure 2 Insert the pressure sensor tube fitting into the hole 2 Loosen the camera sled mounting screws refer to Figure 2 Slide the sensor bracket under the mounting screws and ground lug Tighten the screws 3 Connect the wire leads refer to Figure 2 and Figure 3 on page 7 a Green white wire Insert the push on lug into the connector on the pressure sensor assembly Connect the spade lug to the power terminal block under the AC NEUT wire b White green wire Insert the push on lug into the connector on the pressure sensor assembly Connect the spade lug to the power terminal block above the AC LINE wire 97 uf SCREW WHITE GREEN WIRE GREEN WHITE WIRE GROUND STUD CAMERA SLED SLIDE SENSOR BRACKET UNDER MOUNTING SCREWS AND GROUND STUD Figure 2 EH8100 Series Enclosure Rear Plate Inside View 6 C1445M E 2 09 PRESSURE I SENSOR SWITCH THERMOSTAT AC NEUT ACLINE by A NN
9. rks of their respective companies The absence of a trademark or registered trademark from this document does not constitute a waiver of intellectual property rights C1445M E 2 09 9 C1445M E 2 09 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years Fiber optic products TW3000 Series unshielded twisted pair UTP transmission products CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models e Three years Pelco branded fixed camera models CCC1390H Series C10DN Series C10CH Series and IP3701H Series H1500 Series enclosures Spectra IV products including Spectra IV IP Camclosure Series IS ICS IP integrated camera systems DX Series digital video recorders DVR5100 Series digital video recorders Digital Sentry Series hardware products DVX Series digital video recorders and NVR300 Series network video recorders Endura Series distributed network based video products Genex Series products multiplexers server and keyboard PMCL200 300 400 Series LCD monitors e Two years Standard varifocal fixed focal and motorized zoom lenses F5 DF8 Series fixed dome products Legacy Series integrated positioning systems Spectra
10. the humidity indicator registers the lowest level remove the screwdriver and allow nitrogen to continue to flow into the enclosure until you no longer hear the flow of nitrogen from the tank to the enclosure Remove the tire chuck from the Schrader valve Replace the Schrader valve and pressure relief valve caps POWER CONNECTION 1 2 Reconnect the ground wire to the ground stud on the back of the enclosure Reconnect the electrical connector and turn on power C1445M E 2 09 REVISION HISTORY Manual Date Comments C1445M 12 95 Original version C1445M A 5 96 Updated to include corrections to reference callouts in Section 3 4 Updated Figure 3 All changes in response to ECO 95 220 and 96 131 C1445M B 5 96 Revised to include updated Figures 2 and 4 C1445M C 8 00 Revised installation instructions and wiring diagram layout Updated manual to new format C1445M D 11 04 Factory preset for regulator changed to 12 psi per EC0 04 9807 Updated Important Safety Instructions Warranty and layout C1445M E 2 09 Revised Figure 3 and the reassembly instructions Pelco the Pelco logo Camclosure Digital Sentry Endura Esprit ExSite Genex Intelli M Legacy and Spectra are registered trademarks of Pelco Inc Copyright 2009 Pelco Inc All rights reserved DLP is a registered trademark of Texas Instruments Incorporated All product names and services identified throughout this document are trademarks or registered tradema