Home
Paradyne 8023 Network Card User Manual
Contents
1. Data In Ring Port 4 36 5 Data Out Tip 11 4 Data Out Ring 35 2 Data In Tip 10 1 Data In Ring 12 October 2003 8400 A2 GZ40 10 Table 2 Feature Number 8026 F1 001 Pin Assignments 2 of 2 8026 F 1 001 DS1 or 120 Ohm 50 Position Telco RJ48C Connector E1 Port Connector Pinouts Pinouts Function Port 5 39 5 Data Out Tip 14 4 Data Out Ring 38 2 Data In Tip 13 1 Data In Ring Port 6 42 5 Data Out Tip 17 4 Data Out Ring 41 2 Data In Tip 16 1 Data In Ring Port 7 45 5 Data Out Tip 20 4 Data Out Ring 44 2 Data In Tip 19 1 Data In Ring Port 8 48 5 Data Out Tip 23 4 Data Out Ring 47 2 Data In Tip 22 1 Data In Ring Table 3 Feature Number 8027 F1 001 Pin Assignments 1 of 2 50 Position Telco 75 Ohm E1 Port Function Connector Pinouts BNC Connector Port 1 Data In 1 Shell Ring 26 Pin Tip Data Out 2 Shell Ring 27 Pin Tip Port 2 Data In 4 Shell Ring 29 Pin Tip Data Out 5 Shell Ring 30 Pin Tip 8400 A2 GZ40 10 October 2003 13 Table 3 Feature Number 8027 F1 001 Pin Assignments 2 of 2 50 Position Telco 75 Ohm E1 Port Function Connector Pinouts BNC Connector Port 3 Data In 7 Shell Ring 32 Pin Tip Data Out 8 Shell Ring 33 Pin Tip Port 4 Data In 10 Shell
2. Documentation Online Complete documentation for this product is available at www paradyne com Select Support gt Technical Manuals gt Hotwire DSL Systems Select the following documents 8400 A2 GB20 Hotwire Shelf Concentration and Processing SCP Card User s Guide 8620 A2 GN20 Hotwire 8620 GranDSLAM Installation Guide 8820 A2 GN20 Hotwire 8820 GranDSLAM Installation Guide 8900 A2 GB20 Hotwire ATM Line Cards Models 8955 8965 and 8985 User s Guide To order a paper copy of a Paradyne document or to speak with a sales representative please call 727 530 2000 Refer to the appropriate Hotwire GranDSLAM installation guide to Install and set up the Hotwire GranDSLAM chassis m Connect cables After the SCP card is installed there are configuration procedures that must be performed before you can begin to use the DSL port cards Refer to the Hotwire ATM Line Cards User s Guide and the Hotwire Shelf Concentration and Processing SCP Card User s Guide for detailed configuration procedures Package Contents Verify that the shipping carton contains One SCP card in an anti ESD bag One 14 foot serial cable with modular connectors One DB9 adapter for use with the serial cable This document If anything is missing or damaged contact your sales representative October 2003 8400 A2 GZ40 10 Installing the SCP Card SCP cards can be installed in m SlotA Slot B or both of the 8820 GranDSLAM m Slot A
3. Ring 35 Pin Tip Data Out 11 Shell Ring 36 Pin Tip Port 5 Data In 13 Shell Ring 38 Pin Tip Data Out 14 Shell Ring 39 Pin Tip Port 6 Data In 16 Shell Ring 41 Pin Tip Data Out 17 Shell Ring 42 Pin Tip Port 7 Data In 19 Shell Ring 44 Pin Tip Data Out 20 Shell Ring 45 Pin Tip Port 8 Data In 22 Shell Ring 47 Pin Tip Data Out 23 Shell Ring 48 Pin Tip 14 October 2003 8400 A2 GZ40 10 Equipment List 8400 A2 GZ40 10 The following feature numbers may be used to order SCP cards line cards and related cables Table 4 Feature Numbers Description Feature Number Cards SCP Card DS3 8411 A1 000 SCP Card OC3 STM1 Multimode Fiber 8412 A1 000 SCP Card OC3 STM1 Single Mode Fiber Intermediate Reach 8413 A1 000 SCP Card OC3 STM1 Single Mode Fiber Long Reach 8414 A1 000 SCP Card 8 Port DS1 IMA 8416 A1 000 SCP Card 8 Port E1 IMA 8417 A1 000 MCP GranDSLAM 3 0 8900 B1 211 ADSL2 ATM Line Card 24 ports Annex A 8965 B1 000 ReachDSL 2 2 ATM Line Card 24 ports 8955 B1 000 G SHDSL ATM Line Card 24 ports 8985 B1 000 Cables LC to SC Conversion Cable for SCP Multi Mode Fiber 8400 F 1 001 LC to SC Conversion Cable for SCP Single Mode Fiber 8400 F 1 002 Y Cable for SCP Redundancy 8400 F 1 003 LC Connections Multi Mode Fiber Y Cable for SCP Redundancy 8400 F 1 004 LC connections Single Mode Fiber Y Cable for SCP Redunda
4. in the event of failure but the SCP cards are connected to different uplink devices m Load Sharing Both SCP cards are active and connected to different uplink devices In the event of the failure of one of the cards Dual Link redundancy must be manually enabled If you use two SCP cards configured for redundancy and intend to manage the chassis through the active card s Ethernet port each card must have its own connection to your hub through the connector marked LAN Slot A or B The cable cannot be switched after the backup SCP card becomes the active card Also since the two SCP cards share the same MAC address they cannot both be connected to switch ports on your Ethernet switch 4 October 2003 8400 A2 GZ40 10 DS3 Uplink SCP cards with a DS3 uplink have two BNC jacks one for the transmit direction and one for the receive direction To cable an SCP card with an DS3 uplink 1 Connect the input cable to the RX jack on the faceplate of the SCP card 2 Connect the output cable to the TX jack on the faceplate of the SCP card 3 If the chassis is mounted in a rack direct the cables toward the nearest rail and fasten them with cable ties 03 17463 8400 A2 GZ40 10 October 2003 OC3 Uplink SCP cards with an OC3 uplink use an SFP transceiver that accepts an LC type connector To cable an SCP card with an OC3 uplink 1 Remove the plastic dustcover from the SFP socket 2 Insert the LC connector of your fiber opti
5. Be sure to register your warranty at www paradyne com warranty m Telephone Call our automated system to receive current information by fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback Trademarks We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your name and phone number if you are willing to provide additional clarification Hotwire and MVL are registered trademarks of Paradyne Corporation All other products and services mentioned herein are the trademarks service marks registered trademarks or registered service marks of their respective owners 8400 A2 GZ40 10 Copyright 2003 Paradyne Corporation Printed in U S A 18 October 2003 8400 A2 GZ40 10
6. Log in to the SCP card using the ACT USER command ACT USER SUPERUSER ASN 1500 The default password ASN 1500 will appear as asterisks on your screen 3 Assign an IP address netmask and next hop router using the ED IPPORT command For example ED IPPORT ETH 1 100 MANUAL IPADDR 135 26 10 37 NETMASK 255 255 255 0 GATEWAY 135 26 10 30 1S The GATEWAY in the ED IPPORT command specifies a router for the SCP card to use to create a dynamic route upon receipt of a packet from an unknown host on the Ethernet port To specify a default gateway for the SCP card for the routing of packets for which there is no appropriate route use the SET NE ALL command For example SET NE ALL COM 100 DEFROUTER 135 26 10 20 4 Attach the SCP card to your network using the appropriate LAN connection on your GranDSLAM On the Model 8820 GranDSLAM connect to the LAN SLOT A or LAN SLOT B port depending on where the SCP card is installed On the Model 8620 GranDSLAM connect to the LAN SCM port You can now access the web interface by typing into the Location field of your web browser the IP address assigned to the Ethernet port See Using the Web Interface on page 11 In a configuration with two SCP cards this procedure provides access only to the active SCP card 10 October 2003 8400 A2 GZ40 10 Using the Web Interface 8400 A2 GZ40 10 To access the web interface B gt Procedure 1 Open your web browser Inter
7. PARADY NE Hotwire Shelf Concentration and Processing SCP Card Installation Instructions Document Number 8400 A2 GZ40 10 October 2003 Hotwire Shelf Concentration and Processing Card 8400 A2 GZ40 10 A Hotwire Shelf Concentration and Processing SCP card is a circuit card assembly that comprises a parent card with an ATM switch a backplane interface a processor a cell multiplexer demultiplexer and an uplink childcard The childcard determines the type of ATM uplink supported by the SCP card When the SCP card is used in a Hotwire 8620 or 8820 GranDSLAM chassis it aggregates DSL traffic from each of the DSL port cards in the chassis on the chassis s backplane bus and concentrates it onto an ATM interface The following models are available SCP Card Model ATM Uplink Childcard 8411 A1 000 DS3 8412 A1 000 OC3 STM1 Multimode Fiber 8413 A1 000 OC3 STM1 Single Mode Fiber Intermediate Reach 15 km 8414 A1 000 OC3 STM1 Single Mode Fiber Long Reach 40 km 8416 A1 000 8 Port DS1 IMA Inverse Multiplexing over ATM 8417 A1 000 8 Port E1 IMA The SCP card supports the following line cards m 8955 ReachDSL ATM Card m 8965 ADSL ATM Card 8985 SHDSL ATM Card With a Management Communications Controller MCC card installed in the same chassis the SCP card also supports Hotwire Time Division Multiplexer TDM SDSL and SHDSL cards Models 8775 8777 8779 and 8799 October 2003 1 Product
8. THERNET TX Green Data is being transmitted Blinking Off Inactive RX Green Data is being received Blinking Off Inactive UPLINK LK1 Green The link is active AiE Yellow The link is in an alarm state Off The link is disabled L m L a SCP DS3 SCP OC3 A zal SCP IMA 8411 8412 8417 03 17464 03 17420 03 17421 8 October 2003 8400 A2 GZ40 10 Using the Default Management Address The SCP card uses Transaction Language 1 TL1 language for Command Line Interface CLI commands and messages The CLI can be used to configure and maintain the system but the web interface is recommended You can access the web interface using the default management address or a network address you specify using the CLI see Setting the Management Address Using the CLN gt Procedure To use the default management address 1 Connect a PC to the Ethernet port of the SCP card using a crossover cable 2 Access the web interface by typing the default address 10 10 10 10 into the Location field of your web browser See Using the Web Interface on page 11 8400 A2 GZ40 10 October 2003 Setting the Management Address Using the CLI The management address can be set using the CLI B gt Procedure To set the management address of the SCP card using the CLI 1 Using the supplied cable and DB9 adapter connect a PC with a terminal emulation program to the SERIAL SCM jack of your GranDSLAM This gives you access to the CLI 2
9. around the cable and fasten it If any ferrite chokes are supplied with the SCP card they must be installed to meet EMI requirements Install the choke or chokes as close as possible to the 50 position connector Hold them in place with an adjacent cable tie October 2003 Supplied Cable Tie Mount Panhead Screw E Cable Tie 03 17422 SCP Card LEDs The following table describes the meaning and states of the LEDs on the Hotwire SCP card faceplate Example faceplates are shown at left Type LED LED is Indicating SYSTEM Active Green This SCP card is the active card Slow cycling and is functioning normally Slow cycling describes a recurring pulse when the LED is on longer than off at a ratio of approximately 10 1 AVOID EXPOSURE INVISIBLE LASER RADIATION IS D FROM THIS APERTURE Green On SCP card failure System processing functions have stopped Off No power to card or this is the standby SCP card Standby Green This SCP card is the standby card Slow cycling and is functioning normally Slow cycling describes a recurring pulse when the LED is on longer than off at a ratio of approximately 10 1 Green On SCP card failure System processing functions have stopped Off No power to card or this is the active SCP card Alarm Yellow Alarm is present on the SCP card Off No alarms Test Yellow Test in progress Off No tests E
10. ations ITU G 709 DS3 ATM physical layer interface ATM Forum af phy 0054 000 HEC generation calculation error detection ANSI T1 646 ITU T1 646 Frame Formats PLCP Direct Line Type B3ZS Data Rates Supported 44 736 Mbps October 2003 8400 A2 GZ40 10 Table 5 SCP Card Technical Specifications 2 of 2 Specifications Criteria OC3 Uplink Specifications Number of ports 10C3 Connector Type Duplex LC Socket Standards Supported ANSI T1 105 06 94 Jitter ANSI T1 105 09 94 Jitter ANSI T1 117 06 91 ITU T G 957 7 95 Frame Formats OC3 or STM 1 Operation Direct Mode only Line Type Non Return to Zero Data Rates Supported 155 52 Mbps Facility Datalink Protocol ANSI T1 105 Format ANSI T1 646 HEC ITU T 1 432 Scrambler Cable Distance Model 8412 MMF 2 Km 6561 7 feet Model 8413 SMFIR 15 Km 49 212 6 feet SMF fiber Model 8414 SMFLR 40 Km 131 234 feet SMF fiber IMA Uplink Specifications Number of ports 8 T1 or E1 Connector Type RJ45M type 50 pin telco Standards Supported RFC 495 ANSI T1 403 ITU G 703 G 704 Frame Formats T1 Superframe extended Superframe E1 E1 E1i CRC Line Type T1 B8ZS E1 HDB3 Data Rates Supported T1 1 544 Mbps per T1 max 8 T1 E1 2 048 Mbps per E1 max 8 E1 Facility Datalink Protocol ANSI T1 403 Cable Distance T1 E1 short haul 200 meters 656 feet LBO 0 7 15 22 dB T1 E1 long haul 2000 meters 6561 7 feet Important Safety Instru
11. c cable into the SFP socket 3 Observing the minimum bend radius for your cable fasten it with cable ties in such a way that it will not be kinked or snagged in the course of other cabling If you do not know the specifications for your cable maintain a radius of at least ten times the cable diameter D hee eee Le O es O K Me a Ma Ot yi exe o000 O B 20 2000000 O iO OO 08 17419 6 October 2003 8400 A2 GZ40 10 IMA Uplink 8400 A2 GZ40 10 SCP cards with an IMA uplink have an RJ45M type 50 position connector with eight Tip Ring and eight Tip1 Ring1 connections that conforms to ANSI T1 403 1999 The following splitter cables are available m Feature Number 8026 F1 001 for the Model 8416 SCP card terminates in eight 8 pin modular jacks See Table 2 Feature Number 8026 F 1 001 Pin Assignments on page 12 To connect the SCP card to a switch attach the modular jacks of the 8026 F 1 001 cable to T1 E1 crossover cables and attach the crossover cables to the switch m Feature Number 8027 F1 001 for the Model 8417 SCP card terminates in 16 BNC jacks See Table 3 Feature Number 8027 F 1 001 Pin Assignments on page 13 To cable an SCP card with an IMA uplink 1 Feed the supplied cable tie through the openings in the base of the 50 position connector 2 Fasten the splitter cable to the connector with the captive panhead screw 3 Wrap the cable tie
12. ctions 8400 A2 GZ40 10 The OC3 configuration of the SCP circuit card has provisions for the customer to install Class 1 laser transceivers to provide optical coupling to the telecommunications network Once a Class 1 laser is installed the equipment is considered to be a Class 1 laser product Appareil Laser de Classe 1 If the Class 1 laser device is not purchased from Paradyne Corp the customer is responsible to insure that the Class 1 AEL Allowable Emissions Limit per EN IEC 60825 is not exceeded after the laser transceivers have been installed Do not install laser products whose class rating is greater than 1 Refer to the important safety instructions that accompany the transceiver prior to installation Only laser Class 1 devices certified for use in the country of installation by the cognizant agency are to be utilized with this product Also laser warnings are to be provided in accordance with IEC 60825 1 and its Amendments 1 and 2 as well as 21 CFR 1010 and 1040 10 g October 2003 17 Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods m Internet Visit the Paradyne World Wide Web site at www paradyne com
13. lot 3 SHDSL Port 06 0 35 Slot A OC3 Port 1 2 85 PACKET PACKET User Interface Io Slot 3 SHDSL Port 07 0 35 Slot A OC3 Port 1 2 86 PACKET PACKET Redundancy Date and Time m Slot 3 SHDSL Port 08 0 35 Slot A OC3 Port 1 2 87 PACKET PACKET Syslog o Slot 3 SHDSL Port 09 0 35 Slot A OC3 Port 1 2 88 PACKET PACKET m Slot 3 SHDSL Port 10 0 35 Slot A OC3 Port 1 2 89 PACKET PACKET zl October 2003 11 BNC Jacks The following table shows the connections for BNC jacks Model 8411 Table 1 BNC Jack Connections Connector Label Connection Description Transmit TX Pin Transmit signal Shell Transmit signal return Receive RX Pin Receive signal Shell Receive signal return IMA Interface Pin Assignments Table 2 lists connector pin assignments for Model 8416 and the Model 8417 when used with modular connectors for a 120 ohm E1 connection Table 3 lists connector pin assignments for the Model 8417 when used with BNC connectors for a 75 ohm E1 connection Table 2 Feature Number 8026 F1 001 Pin Assignments 1 of 2 8026 F 1 001 DS1 or 120 Ohm 50 Position Telco RJ48C Connector E1 Port Connector Pinouts Pinouts Function Port 1 27 5 Data Out Tip 2 4 Data Out Ring 26 2 Data In Tip 1 1 Data In Ring Port 2 30 5 Data Out Tip 5 4 Data Out Ring 29 2 Data In Tip 4 1 Data In Ring Port 3 33 5 Data Out Tip 8 4 Data Out Ring 32 2 Data In Tip 7 1
14. ncy 8400 F 1 005 SC Connections Multi Mode Fiber Y Cable for SCP Redundancy 8400 F 1 006 SC Connections Single Mode Fiber Y Cable for SCP Redundancy 8400 F 1 007 DS3 50 Position Connector to Eight 8 Pin Modular Jacks Cable 8026 F 1 001 50 Position Connector to Sixteen BNC Jacks Cable 8027 F 1 001 October 2003 15 SCP Card Technical Specifications 16 Table 5 SCP Card Technical Specifications 1 of 2 Safety Certifications Specifications Criteria Size Length 10 4 inches 26 42 cm Height 11 15 inches 28 32 cm Width 1 0 inches 2 54 cm Weight Approximately 1 7 Ibs 0 76 kg Approvals Refer to the equipment s label for approvals on product Power The SCP card contains a DC to DC converter that requires 48V power input The 48V power is distributed through the Hotwire chassis backplane Power Dissipation DS3 32 watts OC3 29 watts IMA 32 watts Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 32 to 140 F 0 to 60 C 4 F to 158 F 20 C to 70 C 5 to 85 noncondensing Withstands normal shipping and handling DS3 Uplink Specifications Number of ports Connector Type Standards Supported 1DS3 Two 75 ohm BNC jacks Operations violations alarm states perrformance statistics ANSI T1 107 1995 ANSI T1 646 1995 Output jitter ITU G 709 ITU G 783 DS3 electrical specific
15. net Explorer Version 6 or above is recommended 2 Type http and the IP address of the SCP card into the Address field of your browser window This is 10 10 10 10 by default or the address you set using the CLI For example Address E http 135 26 10 37 3 A login window appears Enter the default User ID GSUPERUSER and Password ASN 1500 and click on OK The web interface screen appears 4 Click on the menu tab appropriate to what you would like to do Configuration To configure the system and interfaces Status To display statistics status and contents of memory System To display system information download firmware back up configurations and modify users Tests To start and stop tests PA i FAVADIN a SCP R3 0 Status System Configuration ATM Delete Selected Select All CrossConnects E eos Create New Cross Connect Create Cross Connect by Slot SHDSL General Port Port A VC VPIVCl Port B VC VPI VCl Up Stream Profile Down Stream Profile Segments Line Profile m Slot 3 SHDSL Port 01 0 35 Slot A OC3 Port 1 2 80 PACKET PACKET Alarm Profile oc o Slot 3 SHDSL Port 02 0 35 Slot A OC3 Port 1 2 81 PACKET PACKET Configuration E m Slot3 SHDSL Port 03 0 35 Slot A OC3 Port 1 2 82 PACKET PACKET ATM Mgmt PVC IP Port m Slot 3 SHDSL Port 04 0 35 Slot A OC3 Port 1 2 83 PACKET PACKET IP Security m Slot 3 SHDSL Port 05 0 35 Slot A OC3 Port 1 2 84 PACKET PACKET m S
16. of the 8620 GranDSLAM B gt Procedure To install the Hotwire SCP Card in a GranDSLAM chassis 1 If there is a filler plate covering the slot remove it 2 Remove the yellow screw covers 3 Insert the card into the card guides of the slot on the chassis 4 Carefully slide the card into the slot until the card meets the connectors on the backplane Then press in on the insertion ejection levers until the card is fully seated 5 Verify that the SYSTEM Active or Standby indicator on the card s faceplate is cycling off and on See SCP Card LEDs on page 8 6 Secure the card by fastening the screws on each end of the faceplate This is required to maintain proper gasket pressure on the faceplate as well as proper air flow 7 Attach appropriate connections to the uplink These are described in the following sections DS3 Uplink on page 5 OC3 Uplink on page 6 IMA Uplink on page 7 8400 A2 GZ40 10 October 2003 3 Installing Two SCP Cards in the Same DSLAM Two SCP cards may be installed in one DSLAM to provide redundancy or load sharing There are three basic configurations for paired SCP cards m Y Cable The OC3 ports of the two SCP cards are connected to the same uplink device If the active SCP card fails the backup SCP card automatically becomes the uplink See Equipment List on page 15 for available Y cables Dual Link Automatic switching occurs
Download Pdf Manuals
Related Search
Related Contents
エコビジョン Manuel D`UTILISATION - EuroTeknika Implants ポール用金具ー重量用 取扱説明書 Endless Summer EWUR730SP Instructions / Assembly OM, 570 Auto Tune, 576XP Auto Tune, 576XPG Auto Agrodok-18-Protection des céréales et des légumineuses GE FCM7DAWH User's Manual Pioneer Premier PRS-D4000F User's Manual Gebrauchsanweisung Instructions for use Mode d`emploi Infinitis incite les salariés des assureurs à rejoindre son réseau Copyright © All rights reserved.
Failed to retrieve file