Home

Panasonic KX-TDA15 IP Phone User Manual

image

Contents

1. Doorphone 1 Doorphone 2 Installation Manual 111 2 8 Connection of Doorphones Door Openers External Sensors and External Relays Connection of Door Openers External Sensors and External Relays Use 8 pin and 10 pin terminal blocks included with the card for connection 1 While pressing down on the hole at the top of the terminal block using a screwdriver insert the wire into the side hole as shown below Repeat this procedure for other door openers external sensors and external relays Refer to 2 5 1 DPH4 Card for pin assignments Door Opener c ES External Sensor External Relay Device Liste See he ee ee eS To door openers external relays To external sensors 112 Installation Manual 2 9 Connection of Peripherals 2 9 Connection of Peripherals 2 9 1 Connection of Peripherals Cable Maximum Distance 26 AWG to 22 AWG 10 m 32 ft 10 m 32 ft Cable Maximum Distance l ae n 26 AWG to 22 AWG 10m 32 ft LO ene CAT 5 10 m 32 ft Pager i Amplifier Speaker Maximum Distance 2m 6 ft PC Printer Maximum Distance 5 m 16 ft
2. BGM MOH The Hybrid IP PBX provides Background Music and Music on Hold Only 1 external music source e g a user supplied radio can be connected to the Hybrid IP PBX CAUTION e Wiring should be done carefully to prevent undue force being exerted on the plug Otherwise music may be intermittent e An External Music Jack is a SELV port and should only be connected to an approved SELV device Note When the Hybrid IP PBX and external music sources are not connected to the same ground hum noise may be induced into Background Music and Music on Hold Installation Manual 113 2 9 Connection of Peripherals Pager Only one paging device user supplied can be connected to the Hybrid IP PBX CAUTION An External Paging Jack is a SELV port and should only be connected to an approved SELV device PC Printer via RS 232C The Hybrid IP PBX is equipped with an RS 232C interface This interface provides communication between the Hybrid IP PBX and the user supplied devices such as PC or line printers The RS 232C port is used for system programming SMDR diagnostics and external system database storage save load functions When using special accessories such as cable the user should use those specified in this installation manual to comply with the limits for a Class B digital device pursuant to the FCC Rules Note Use an RS 232C cross cable for connection between the Hybri
3. Signal Name Function D2 DI D1 Data port High Ei D2 Data port Low ae z Reserved 1 The PT interface CS can be connected to the Hybrid IP PBX using a cable like a PT Installation Manual 67 2 4 Installation of the Extension Cards 2 4 6 SLC8 Card Function 8 port extension card for SLTs To extensions Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Pin Assignments RJ11 Connector Signal Name Function RT T Tip H R Ring i Reserved 68 Installation Manual 2 4 Installation of the Extension Cards 2 4 7 PLC8 Card Function 8 port extension card for APTs DSS consoles and a VPS To extensions Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Pin Assignments RJ11 Connector Signal Name Function ea Di D1 Data port High i T Tip TIT R Ring 4 1 i D2 Data port Low Installation Manual 69 2 5 Installation of the Other Cards 2 5 Installation of the Other Cards 2 5 1 DPH4 Card Function 4 port doorphone card for 4 doorphones 4 door openers or external relays and 4 external sensors LE 5 GARE gt To external sensors I SE Telephone Line Cord To d
4. 127 3 3 1 Installing and Starting the KX TDA50 Maintenance COnsole n 127 4 TEGUDISSIOOUING seesssssnsnnnssusnssccedattavssisavedsanuannnnutiniacadsddecdssssaisidieastaannnnn 133 4 1 Troubleshooting adi ssscesinesszesnes fuses doe sens tsa casenstaseesssentccsecsncoasseatesescesscesssessce2cceesceseecsseesesese 134 4 1 1 Installation 134 AN Connection aulin 136 4 1 3 CE oa 138 4 1 4 Using the ResetBultoncinc carla 140 4 1 5 Troubleshooting by Error Logistic 141 5 Appendice 151 5 1 Revision HistolV reali 152 bol MPR Version 1I errie eia aeaa aa iaa aa 152 51 2 MPR Version 2 0 153 gt PR RR T A ER 155 Installation Manual Section 1 System Outline This section provides general information on the Hybrid IP PBX including the system capacity and specifications Installation Manual 15 1 1 System Highlights 1 1 System Highlights 1 1 1 System Highlights Networking Features The Hybrid IP PBX supports the following private networking features TIE Line Service PBXs can be connected via a privately leased telephone lines forming a private network These TIE lines provide a cost effective way to route calls and communications and are often used to connect corporate offices located in different cities QSIG Support TIE line service can be used on a private network that implements the QSIG protocol Q 931 QSIG offers TIE line service as well as advanced caller and
5. e Do not block the openings of the cabinet Leave at least 20 cm 8 in of space above and 10 cm 4 in to the sides of the Hybrid IP PBX for ventilation e Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on the back of the cabinet will not be blocked e Be careful not to drop the cabinet 50 Installation Manual 2 2 Installation of the Hybrid IP PBX Mounting on Concrete or Mortar Wall CAUTION Drive mounting screws into the wall Be careful to avoid touching any metal laths wire laths or metal plates in the wall 1 Place the reference for wall mounting on the last page of this manual on the wall to mark the three screw positions 130 mm 5 1 8 in 250 mm 9 13 16 in 2 Install three anchor plugs user supplied in the wall Hammer Anchor Plug 6 4 mm 1 4 in 29 mm 1 1 8 in 3 Install the screws included in the wall Drive the screw to this position 4 Hookthe main unit on the screw heads NEO L i ILS III Lu p M ill Ta wigs ee 5 Installation Manual 51 2 2 Installation of the Hybrid IP PBX Notes e Do not block the openings of the cabinet Leave at least 20 cm 8 in of space above and 10 cm 4 in to the sides of the Hybrid IP PBX for ventilation e Make sure that the wall behind the cabinet is flat and free of obstacles so that the openings on
6. IT KX TDA5175 Voice Processing APT DSS Console System DPH4 KX TDA5161 I ECHO8 E KX TDA5166 l Doorphone amp Door Opener External Sensor External Relay Device MEC EXT CID KX TDA5105 KX TDA5168 Station Message Detail Recording SMDR e Pager Amplifier RMT MSG2 Speaker KX TDA5196 KX TDA5191 Gn o Kx T7696 Radio 4 Super Hybrid Ports Q aP Ce m o q latin fk KX 17633 e ia 2 d CTI Server PC MS PT interface CS PS Voice KX T7600 DPT KX T7600 DPT Processing Main Board System 1 One LCOT4 card is installed by default 2 In addition to the supplied AC adaptor an additional AC adaptor can be connected to the Hybrid IP PBX 3 The Hybrid IP PBX has 4 Super Hybrid Ports pre installed 20 Installation Manual 1 3 Options 1 3 Options 1 3 1 Options RO Maximum Model No Model Name Description Quantity KX TDA5105 Memory Expansion Card Memory expansion card to increase Personal 1 MEC System Speed Dialing number storage space double the number of DPTs using Digital XDP connection and display language selection for VM Menu To be installed in the MEC slot KX TDA5161 4 Port Doorphone Card 4 port doorphone card for 4 doorphones 4 door 1 DPH4 openers or external relays and 4 external sensors KX TDA5166 8 Channel Echo Canceller 8 channel card for echo cancellation during 1 Card ECHO8 con
7. Terminal Equipment Type Without Additional AC With Additional AC Adaptor Adaptor Without MEC Card Without MEC Card With MEC Card SLT 24 24 A seres PE URS Total 24 Total 24 Total 48 KX T7600 series DPT 24 24 48 KX T7600 series DSS console 4 4 Other DPT DSS console and APT Total 4 Total 24 Other DPT 4 24 Other DSS console 4 4 APT 4 24 DSS console 4 4 CS 4 8 PS 28 28 VPS 4 ports 1 VPS 1 4 ports 1 VPS 1 SLT PT DSS console and VPS Total 28 Total 28 Total 52 Doorphone 4 Door Opener External Relay 4 4 External Sensor 4 Add on Key Module 48 panini Total 24 Total 24 si 1 A maximum of 4 ports 8 channels of a single VPS can be connected to the Hybrid IP PBX Installation Manual 1 4 Specifications Note Devices connected to the Hybrid IP PBX that exceed the system capacity will not function MEC Card Calculation Calculate the MEC figure from the type and total number of items of equipment to be connected If the MEC figure exceeds 28 you need to install an MEC card Note that you also need to connect an additional AC adaptor in this case MEC Card Calculation Equipment Type MEC Figure PT KX T7600 series DPT DSS console 1 Other DPT DSS console 1 APT 1 Pre installed 4 Super Hybrid Ports 4 Extension Card SLC4 4 SLC8 8 HLC4 0 PLC4 0 PLC8 0 CS 1 unit 0 VPS 1 port 1 1 Only the extension cards that can support SLTs count for
8. KX TDA5105 Memory Expansion Card MEC Changed Contents e 1 4 3 System Capacity 152 Installation Manual 5 1 Revision History 5 1 2 MPR Version 2 0 New Options e System Components Table KX TDA5920 SD Memory Card for Software Upgrade to Enhanced Version Changed Contents e 1 4 3 System Capacity e 2 8 1 Connection of Doorphones Door Openers External Sensors and External Relays Installation Manual 153 5 1 Revision History 154 Installation Manual Index Installation Manual 155 Index Numerics 2 Channel Message Card KX TDA5191 21 74 4 Channel VoIP Gateway Card KX TDA5480 22 61 4 Port Analog Trunk Card KX TDA5180 21 59 4 Port Caller ID Card KX TDA5193 21 60 4 Port Digital Extension Card KX TDA5171 21 64 4 Port Doorphone Card KX TDA5161 21 70 4 Port Hybrid Extension Card KX TDA5170 21 63 4 Port Proprietary Extension Card KX TDA5175 21 66 4 Port Single Line Telephone Extension Card KX TDA5173 21 65 8 Channel Echo Canceller Card KX TDA5166 21 73 8 Port Digital Extension Card KX TDA5172 21 67 8 Port Proprietary Extension Card KX TDA5176 21 69 8 Port Single Line Telephone Extension Card KX TDA5174 21 68 A About the Other Manuals 9 AC Adaptor Selection 27 Additional AC Adaptor KX A236 22 After Site Survey 100 Appendix 151 Basic System Construction 18 Before Installation 30 Before Site Survey 94 Built in Small Call Center Features 16 C Cal
9. Operator call and Idle Line Access ARS numbers 0 or 9 The feature numbers for operator call and Idle Line Access ARS can be selected Remote Maintenance Dial Number Enter the complete telephone number of the Hybrid IP PBX including the country code When necessary this number will be used to access the Hybrid IP PBX from a remote location for maintenance purposes 1 Connect the PC to the Hybrid IP PBX with a USB cable 2 Start the KX TDA50 Maintenance Console from the Start menu 128 Installation Manual 3 3 Installation of the Hybrid IP PBX PC Programming Software SS 3 Type the Installer Level Programmer Code INSTALLER then click OK Enter Programmer Code Ji The Programmer Code authorizes different programming levels and the Quick Setup is only available when you start oma e the KX TDA50 Maintenance Console with the Installer Level Programmer Code Note There are 2 other Programmer Codes with limited authorization Administrator Level ADMIN and User Level USER 4 Click Connect USB from the menu bar File Connect Tool Utility View Window Help 2 52 2 Modem Disconnect A a x 5 Type the system password for installer default 1234 then Password II coca e click OK to log in Quick Setup Step i 6 Follow the instructions of the wizard and assign the basic item ick Setup Date amp Time 2003 108123 12000 sita Qu CER up Help
10. e Be aware that pressing the Reset Button with the System Initialize Switch in the SYSTEM INITIALIZE position clears all data stored in the Hybrid IP PBX Do not perform this operation unless you intend to delete all data from the Hybrid IP PBX Operation If the Hybrid IP PBX does not operate properly 1 Set the System Initialize Switch to the NORMAL position 2 Press the Reset Button RUN Indicator ALARM Indicator N RESET l BE Reset Button System Initialize Switch SYSTEM INITIALIZE NORMAL e f f CHO OC 140 Installation Manual 4 1 Troubleshooting 4 1 5 Troubleshooting by Error Log When a major system error occurs in the Hybrid IP PBX the ALARM indicator on the front of the cabinet turns on red and the system logs the error information Error Log Display Format Below is the display format of the error log To see the error log using the KX TDA50 Maintenance Console refer to the on line help of the KX TDA50 Maintenance Console Example KX TDA50 Maintenance Console E Kx TDA50 Maintenance Console Error Log File Connect Tool Utility view Window Help Error Message Example Station Message Detail Recording SMDR 04 01 01 10 37AM MJ ALM 000 10000 MPR WDT overflow 04 01 01 11 07AM MN ALM 010 10000 AC power down 04 01 01 03 5
11. 250 mm 9 13 16 in TN yy 240 mm 9 7 16 in AN a Install a Install a screw here screw here 130 mm 5 1 8 in Reference for Wall Mounting D Note Make sure to set the print size to correspond with the size of this page If the dimensions of the paper output still deviate slightly from the measurements indicated here use the measurements indicated here Install a screw here 65 mm 2 9 16 in DA ay 120 mm 4 3 4 in Panasonic Consumer Electronics Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus NJ 07094 Panasonic Puerto Rico Inc Ave 65 de Infanteria Km 9 5 San Gabriel Industrial Park Carolina Puerto Rico 00985 http www panasonic com csd Copyright This material is copyrighted by Panasonic Communications Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic Communications Co Ltd 2004 Panasonic Communications Co Ltd All Rights Reserved PSQX3100WA KK0104EK3055
12. e Parallel mode or XDP mode can be selected through system programming e If XDP mode is enabled through system programming parallel connection is not possible Refer to 1 10 9 Paralleled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information With KX T7600 Series DPT Using a Modular T Adaptor To DLC4 DLC8 card lt To a Super Hybrid Port Modular for connection of SLT T Adaptor Sage wiag oid Connect pins T and R 4 conductor wiring cord 4 conductor wiring cord Connect pins sland ber Connect pins D1 and D2 SLT Master DPT Slave DPT TO MAIN UNIT Maximum Distance p 30 m 98 ft 9 rN oa 50 m 164 ft 3 i i fs 60 m 196 ft Ia i LN I 50 m 164 ft sa RES TO MAIN UNIT PABX Master DPT 4 i To DLC4 DLC8 card l To a Super Hybrid Port i for connection of SLT 84 Installation Manual 2 6 Connection of Extensions Using an EXtra Device Port To DLC4 DLC8 card 7 e t To a Super Hybrid Port 4 conductor wiring cord for connection of SLT Connect pins T R 2 conductor wiring cord D1 and D2 Connect pins T and R 4 conductor wiring cord Connect pins T R 7 D1 and D2 Maximum Distance i 5 30m 98 ft 50m 164 ft f T 60 m 196 ft 50 m 164 ft at 9 TO MAIN UNIT os 9 i PABX Master DPT 4 4 To DLC4 DLC8 card
13. 1246 ft Digital XDP connection 24 AWG 550 m 1804 ft 22 AWG 630 m 2066 ft CAT 5 550 m 1804 ft e al Cable Maximum Distance ss Wa 26 AWG 140 m 459 ft 24 AWG 229 m 751 ft 22 AWG 360 m 1181 ft CAT 5 229 m 751 ft Ta _ Cable Maximum Distance 26 AWG 698 m 2289 ft SLT 24 AWG 1128 m 3700 ft 22 AWG 1798 m 5897 ft vi CAT 5 1128 m 3700 ft dai da iii Notice The maximum cabling distance may vary depending on the conditions 80 Installation Manual 2 6 Connection of Extensions DSS Console PT interface CS DPT APT SLT KX T7600 series Other Super Hybrid Ports Main Board v v v v v SLC4 SLC8 Cards v4 DLC4 DLC8 Cards Vv Vv Vv Vv PLC4 PLC8 Cards Vv Y HLC4 Card Vv Vv Vv Vv Vv VY indicates that the extension card or Super Hybrid Ports support the terminal Installation Manual 81 2 6 Connection of Extensions 2 6 2 Parallel Connection of the Extensions Any SLT can be connected in parallel with an APT or a DPT as follows Note In addition to an SLT an answering machine a fax machine or a modem PC can be connected in parallel with an APT and a DPT With APT To a Super Hybrid Port lt 4 Modular amp T Adaptor t4 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 gt and D2 APT SLT With DPT Parallel mode or eXtra Device Port XDP m
14. 14 15 Read and understand all instructions Follow all warnings and instructions marked on the product Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Clean with a damp cloth Do not use this product near water for example near a bathtub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool Do not place the product on an unstable surface as a fall may cause serious internal damage Slots and openings in the front back and bottom of the cabinet are provided for ventilation to protect it from overheating these openings must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface while in use The product should never be placed near or over a radiator or other heat source This product should not be placed in a sealed environment unless proper ventilation is provided The product should only be connected to the type of electrical power supply specified on the product label If you are not sure of the type of power supply to your home consult your dealer or local power company For safety purposes this unit is equipped with a grounded plug If you do not have a grounded outlet please have one installed Do not bypass this safety feature by tampering with the plug Do not allow anything to rest on the power cord Do not locate this product where the power cord may be step
15. Output 1 conductor jack Mode Conversion DP DTMF DTMF DP Ring Frequency 20 Hz 25 Hz selectable Central Office Loop Limit 1600 Q maximum Operating Temperature 0 C to 40 C 32 F to 104 F Environment Humidity 10 to 90 non condensing Conference Call CO Line From 10 x 3 party conference call to 4 x 8 party conference call Music on Hold 1 port Level Control 11 dB to 11 dB in 1 dB steps Selectable Tone External Music Source port Paging Internal Level Control 15 dB to 6 dB in 3 dB steps External 1 port Volume Control 15 dB to 15 dB in 1 dB steps Serial Interface RS 232C 1 maximum 115 2 kbps Port USB Installation Manual 23 1 4 Specifications Extension Connection Cable SLT 1 pair wire T R DPT 1 pair wire D1 D2 or 2 pair wire T R D1 D2 APT 2 pair wire T R D1 D2 PT interface CS 1 pair wire D1 D2 DSS Console and Add on Key Module 1 pair wire D1 D2 Dimension 275 mm W x 376 mm H x 117 mm D 10 4 5 in x 14 4 5 in x 4 3 5 in Weight when fully mounted Under 3 5 kg 7 72 Ib 24 Installation Manual 1 4 Specifications 1 4 2 Characteristics Terminal Equipment Loop Limit e PT KX T7600 series 90 Q all other DPTs APTs 40 Q e SLT 600 Q including set e Doorphone 20 Q e PT interface CS 65 Q Minimum Leakage Resista
16. RMT Analog modem card for remote communication 1 with the Hybrid IP PBX ITU T V 90 support KX TDA5480 4 Channel VoIP Gateway 4 channel VoIP gateway card Compliant with 1 Card IP GW4 VoIP H 323 V 2 protocol and ITU T G 729a G 723 1 and G 711 CODEC methods KX TDA5920 SD Memory Card for Optional SD Memory Card to upgrade the 1 Software Upgrade to Hybrid IP PBX with MPR version 1 or 1 1 to Enhanced Version version 2 0 and for NDSS feature and CTI enhancement KX A236 Additional AC Adaptor AC adaptor and AC cord for system expansion 1 1 The PT interface CS can be connected to the Hybrid IP PBX using a cable like a PT 2 One LCOT4 card is installed by default Two more LCOT4 cards can be optionally installed in the Hybrid IP PBX 22 Installation Manual 1 4 Specifications 1 4 Specifications 1 4 1 General Description Switching Non blocking AC Adaptor AC Input 100 V AC to 240 V AC 1 5 A 50 Hz 60 Hz DC Output 40 V 1 38 A 55 2 W DC Input e DCIN 1 40 V 1 38 A 55 2 W e DC IN 2 40 V 1 38 A 55 2 W Maximum Power Failure Tolerance 300 ms Memory Backup Duration 7 years Dialing CO Line Dial Pulse DP 10 pps 20 pps Tone DTMF Dialing Extension Dial Pulse DP 10 pps 20 pps Tone DTMF Dialing Connectors CO Line RJ11 2 wire x each CO ports Extension RJ11 4 wire x each extension ports Paging Output 1 conductor jack External MOH Music on Hold
17. Site Survey Change the access system setting of the PS to the appropriate system or automatic 138 Installation Manual 4 1 Troubleshooting PROBLEM PROBABLE CAUSE SOLUTION Noise is frequent while using the PS Conversations disconnect while using the PS Call handover is not working while using the PS PS is out of CS coverage area Locate the CS properly refer to 2 7 5 Site Survey PS stays out of service when the CS status is changed from Out of Service to In Service It may take about 10 s for CS to start up after the status has been changed to In Service Wait until the CS starts up Installation Manual 139 4 1 Troubleshooting 4 1 4 Using the Reset Button If the Hybrid IP PBX does not operate properly use the Reset Button Before using the Reset Button try the system feature again to confirm whether there definitely is a problem or not CAUTION In order to avoid possible corruption of data on the SD Memory Card please ensure that the SD ACCESS LED is off before pressing the Reset Button Notes e When the System Initialize Switch is set to the NORMAL position pressing the Reset Button causes the following Camp on is cleared Calls on hold are terminated Calls on exclusive hold are terminated Calls in progress are terminated Call park is cleared Other data stored in memory except the above are not cleared
18. System Password 1234 Re enter System Password Please change the system password from default If you did not change this the system security problem may happen on your PBX system Installation Manual 129 3 3 Installation of the Hybrid IP PBX PC Programming Software 7 The program menu appears You may now begin File Connect Tool Utility View Window Help programming the Hybrid IP PBX D w ed eela 2 System 3 Groups 4 Extension 5 Optional Device 6 Feature 7 TRS s ARS 9 Private Network 10 00 amp Incoming Call 11 Maintenance E Cameos e During long programming sessions it is highly recommended that you periodically save the system data to the SD Memory Card If the Hybrid IP PBX suffers a sudden power failure or if the system is reset for some reason and all system data is lost it can be restored from the SD Memory Card To save the system data to the SD Memory Card either click the SD Memory Backup icon or exit KX TDA50 Maintenance Console and click Yes to save when prompted e When programming Hybrid IP PBX data which can be displayed on a proprietary telephone PT extension names group names System Speed Dialing names etc it is possible to enter characters which cannot be displayed on a KX T7600 series PT Characters which can be displayed on a KX T7600 series PT are shown bel
19. To install or uninstall the software into Windows 2000 Professional or Windows XP Professional the user must be grouped either of Administrators or Power Users When the Hybrid IP PBX is first connected to the PC via USB a wizard should appear and ask you to select the appropriate USB driver Browse for and select the KX TDA USB driver which is copied to the local drive during installation 1 CopytheKX TDA50 Maintenance Console setup file to a local drive on the PC Its icon is shown here on the left 2 Double click the setup file to run the installer 3 Follow the on screen instructions provided by the installation wizard Starting the KX TDA50 Maintenance Console and Assigning the Basic Items Quick Setup When you start the KX TDA50 Maintenance Console with the Installer Level Programmer Code and connect to the Hybrid IP PBX for the first time after initialization with the factory default setting Quick Setup will launch automatically During Quick Setup you will setup the following basic items Date and Time of the Hybrid IP PBX The date and time set on the PC will be used System Password for installer for PC programming Operator extension numbers Operator extensions for all time modes day lunch break night can be assigned Flexible Numbering type to pattern 1 or pattern 2 If pattern 1 with x is selected must prefix all feature numbers except access numbers when an extension user wants to use a feature
20. regulations and guidelines Safety Installation Instructions When installing telephone wiring basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 2 3 4 Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Installation Precautions This Hybrid IP PBX is designed for wall mounting only and should be installed in a location where it is accessible for inspections and maintenance To prevent malfunction noise or discoloration avoid installing the system in the following locations SU de In direct sunlight and hot cold or humid places Temperature range 0 C to 40 C 82 F to 104 F Areas where sulfuric gases may be present such as near thermal springs Areas where shocks or vibrations are frequent or strong High dust areas or places the system may come into contact with water or oil Near devices that generate high frequencies such as sewing machines or electric welders On or near computers telexes or other office equipment as well as microwave ovens or air conditioners It is preferable not to install the system in
21. Accessories included Extension Bolt x 1 Screw x 1 User supplied not included none Note To establish a conference call involving 6 to 8 parties install an ECHO8 card and enable the echo cancellation for conference using the KX TDA50 Maintenance Console For details refer to the on line help of the KX TDA50 Maintenance Console Installation Manual 73 2 5 Installation of the Other Cards 2 5 3 MSG2 Card Function 2 channel message card Accessories and User supplied Items Accessories included Extension Bolt x 1 Screw x 1 User supplied not included none 74 Installation Manual 2 5 Installation of the Other Cards 2 5 4 EXT CID Card Function Sends Caller ID signals to extension ports Accessories and User supplied Items Accessories included Extension Bolt x 1 Screw x 1 User supplied not included none Installation Manual 75 2 5 Installation of the Other Cards 2 5 5 MEC Card Function Memory expansion card to increase Personal System Speed Dialing number storage space double the number of DPTs using Digital XDP connection and display language selection for VM Menu To be installed in the MEC slot MEC Slot Accessories and User supplied Items Accessories included none User supplied not included none CAUTION Make sure to insert the MEC card between the guide rails until it locks into the MEC slot Push the card firmly into place until you hear a click
22. Compliant with VoIP H 323 V 2 protocol and ITU T G 729a G 723 1 and G 711 CODEC methods To private IP network Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ45 connector Notes e Maximum length of the cable to be connected to this optional service card is 100 m 328 ft e For programming instructions and other information about the IP GW4 card refer to the documentation for the IP GW4 card e To confirm the CO line connection refer to Confirming the CO Line Connection in 2 11 1 Starting the Hybrid IP PBX Pin Assignments RJ45 Connector 10BASE T 100BASE TX Signal Name Input 1 Output O Function TROS TPO O Transmit data iia TPO O Transmit data TT TPl I Receive data l i TPI l Receive data Reserved Installation Manual 61 2 3 Installation of the CO Line Cards LED Indications Indication Color Description ON LINE Green On line status indication e ON On line mode e OFF Off line mode e Flashing Maintenance mode Note If the LINK indicator is OFF the ON LINE indicator will also be OFF ALARM Red Alarm indication e ON Alarm OFF Normal LINK Green Link status indication ON Normal Connection OFF Connection Error DATA Green Data transmission indication e ON Data transmitting OFF No data transmitted 62
23. GHz Portable Stations 3 After setting the DIP switch connect an AC adaptor or battery box to the CS using a power supply adaptor Note The AC adaptor should be connected to a vertically oriented or floor mounted AC outlet Do not connect the AC adaptor to a ceiling mounted AC outlet as the weight of the adaptor may cause it to become disconnected Telephone Cord Power Supply Adaptor PSZZ1TDA0142 To AC Adaptor KX A11 KX TCA1 Battery Box PSZZTD142CE Modular 4 Install the CS temporarily for the site survey Install the CS at least 2 m 6 ft 7 in above the floor keeping the antennas in the upright position Installation Manual 95 96 2 7 Connection of 2 4 GHz Portable Stations 2 7 5 Site Survey The PS has a Radio Signal Test mode that monitors the state of the radio link to the CS After installing the CSs temporarily set the PS to the Radio Signal Test mode and measure each CS coverage area Then record the results on the map of the installation site Testing the Radio Signal Strength Note The display language for the site survey is only in English 1 Enter the Radio Signal Test mode Using the KX TD7680 Display example DEI gt gt lt lt SEARCHING gt gt 5 Press 1 9 and POWER 1t09 SAVE 0123456789 for more than 2 seconds CS NO 1 LEVEL 12 To store the scan data gt Scan Data No Using the KX TD7690 Display example DAA gt
24. Hybrid IP PBX LED Indications Indication Color Description RUN Green PBX status indication e OFF Power off includes normal reset e ON Power on and running on line e Flashing 60 times per minute Starting up e Flashing 120 times per minute Starting up or resetting with e the System Initialize Switch in SYSTEM INITIALIZE position e the SD Memory Card not inserted ALARM Red Alarm detection status indication e OFF Normal e ON Alarm CPU stop alarm for each card e Flashing Alarm MPR file error in restarting Confirming the CO Line Connection After initialization program the Hybrid IP PBX and establish CO line connection and then use a PT to confirm it To confirm dial X 3 7 CO line number 3 digits or press an S CO button You will hear a dial tone if CO line is available and connected Turning off the Hybrid IP PBX For safety reasons make sure to turn off the power switch before unplugging the Hybrid IP PBX To unplug follow the reverse steps to plug it in Installation Manual 121 2 11 Starting the Hybrid IP PBX 122 Installation Manual Section 3 Guide for the Hybrid IP PBX PC Programming Software This section explains the installation and structure of the Hybrid IP PBX PC Programming Software Installation Manual 123 3 1 Overview 3 1 Overview 3 1 1 Overview KX TDA50 Maintenance Console is designed to serve as an overall system p
25. PBX CAUTION e SD Memory Card must be inserted in the SD Memory Card slot of the main board before start up e Before touching the System Initialize Switch discharge static electricity by touching ground or wearing a grounding strap e Once you have started the Hybrid IP PBX and if you unplug the Hybrid IP PBX do not perform the following procedures to start the Hybrid IP PBX again Otherwise your programmed data is cleared To restart the Hybrid IP PBX refer to 4 1 4 Using the Reset Button e The Hybrid IP PBX will continue to be powered even if the power switch is turned OFF e The power supply cord is used as the main disconnect device Ensure that the AC outlet is located near the equipment and is easily accessible 1 Set the System Initialize Switch to the SYSTEM INITIALIZE position RUN Indicator a ALARM Indicator RESET a Reset Button 4 O pen System Initialize Switch SYSTEM INITIALIZE NORMAL e fi f fi Oooo 639 id 118 Installation Manual 2 11 Starting the Hybrid IP PBX 2 Plug the DC connector of the AC adaptor into DC IN 1 DC Connector AC Adaptor Notes The AC adaptor supplied with the Hybrid IP PBX must be connected to DC IN 1 If an AC adaptor i
26. Pass the cable through the groove of the CS in any direction depending on your preference TO MAIN UNIT PABX 4 To a Super Hybrid Port or HLC4 DLC4 DLC8 card 102 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations Registering the PS The PS must be registered to the Hybrid IP PBX before it can be used Programming of both the PS and Hybrid IP PBX is required A PT with multiline display e g KX T7636 6 line display is required for the Hybrid IP PBX system programming Note For details about system programming using a PT refer to 2 3 2 PT Programming and 3 3 PT Programming in the Feature Guide Entering the System Programming Mode PT Administrator Level O System Password for Administrator PROGRAM gt gt for PT Programming gt Programming No PAUSE 1234 3 digits PS Using the KX TD7680 S gt Dr DOW ror DB Or Press POWER Select Select for 2 seconds PS PROGRAM SYSTEM SET ifrequred gt gt System Lock Password gt 2 System Setting Menu 4 digits A A i E oe bl PS Using the KX TD7690 A gt Sb gt S S Press POWER SI Select SI Select SI for 2 seconds PS PROGRAM SYSTEM SETTING Hfrequired aC System Lock Password gt System Setting Menu Loi 4digits Sl it Note means default value throughout this section Installation Manual 103 2 7 Connection of 2 4 GHz
27. Portable Stations PS Registration 690 gt gt gt PSNo Extn No gt CO gt Toners gt E 001 to 028 1 to 4 digits below END ENTER ENTER 33 When the PS has not been registered yet When registering the PS for the first time it is possible to select the desired language for the display You do not need to enter the PS system programming mode when registering for the first time Using the KX TD7680 F2 F3 BH C Tone Press Press S2 repeatedly Press S3 POWER for to select the desired for 2 2 seconds language seconds Using the KX TD7690 gt A gt 2 gt EEB d gt BH 2 O C Tone Press Press S2 repeatedly Press S3 POWER for to select the desired for 2 2 seconds language seconds When the PS has already been registered to another Hybrid IP PBX One PS can be registered to a maximum of 4 different Hybrid IP PBXs Using the KX TD7680 gt eor e gt et C Tone Select Choose REGISTRATION SYSTEM 1 4 Using the KX TD7690 SEL SEL gt Db MV gt Dy z Ca DI C Tone Select SI Choose SI REGISTRATION SYSTEM 1 4 Setting the System Lock When a system lock has been set the system lock password will be required for PS system setting Using the KX TD7680 Do gt E r Q r Choose Select n i i SYSTEM LOCK Enable Disable gt gt 2 gt System Lock Password gt 2 System Lock Password gt gt ENABLE ne igit pee
28. To SLT To a Super Hybrid Port H for connection of SLT Installation Manual 85 2 6 Connection of Extensions 2 6 4 First Party Call Control CTI Connection CTI connection between a PC and a KX T7633 T 7636 DPT provides first party call control The CTI connection is made via a USB interface version 1 1 and uses the TAPI 2 1 protocol A USB Module KX T7601 must be connected to the KX T7633 T7636 DPT Note The operating system of the PC required for first party call control depends on your CTI application software For details refer to the manual for your CTI application software To PC USB Port USB Module e Maximum length of the USB cable is 3 m 9 ft 10 in e USB Modules must not be connected to DPTs in the Digital XDP connection In a Digital XDP connection the PC cannot be used If a USB module is connected to a slave DPT the DPT will not work properly 86 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations 2 7 2 7 1 Connection of 2 4 GHz Portable Stations Overview The following equipment is required to connect the wireless system CS Cell Station KX T0141 This unit determines the area covered by the wireless system Up to 2 calls can be made at the same time through each CS PS 2 4 GHz Portable Station KX TD7680 KX TD7690 The KX TDA50 can support up to 28 PSs For more details about the PS refer to the PS Operating Instructions CAUTION Th
29. Vv Vv SLC8 2 3 Vi viv PLC8 Vv Vv Vv DPH4 1 Viiv ECHO8 1 Vv Vv Vv Vv EXT CID 1 Y Y Vv Vv MSG2 2 Vv Vv Vv 1 Including one LCOT4 card that is installed by default 2 Only one of HLC DLC4 SLC4 or PLC4 card can be installed Installation Manual 39 2 2 Installation of the Hybrid IP PBX 3 A maximum of two DLC8 SLC8 and PLC8 cards can be installed CAUTION To protect the main board from static electricity do not touch parts on the main board or on the optional service cards To discharge static electricity touch ground or wear a grounding strap Notes e When installing or removing the optional service cards the power switch of the Hybrid IP PBX must be in the off position e For each card the maximum number that can be installed in the Hybrid IP PBX is listed in 1 3 1 Options e Any card that exceeds the capacity of the Hybrid IP PBX will be ignored e When the Hybrid IP PBX starts up with an invalid configuration some cards will be ignored Installing Optional Service Cards 1 Before installing the optional service cards cut and remove the appropriate dummy cover plates from the main unit CAUTION For safety reasons smooth the cut edges after removing the dummy cover plates 40 Installation Manual 2 2 Installation of the Hybrid IP PBX 2 Position the card in the open slot making sure that the tabs on the both sides of the card fit in
30. called party identification features Voice over Internet Protocol VoIP Network The Hybrid IP PBX can be used on a private network which implements VoIP On this type of network information is sent over the private network in IP packets which allows voice as well as data to be sent to other devices in the private network Built in Small Call Center Features Extensions can form an incoming call distribution ICD group and be used as a small call center which can take advantage of several features some of which are highlighted below Queuing When all available extensions in an ICD group are busy additional calls can be placed in a queue as they arrive While calls are waiting in the queue callers can hear background music BGM an outgoing message OGM etc Log in Log out Members of an ICD group can log in to or log out of a group manually Group members can log in at the beginning of a work shift and log out at the end of the day While logged in ICD group members can be allotted a specified amount of time after completing a call during which new calls will not be received by their extensions allowing them to finish any necessary paperwork before being eligible to receive new calls Wrap up VIP Call The VIP Call feature is one method of making sure that calls from preferred customers or callers are answered quickly When using VIP Call mode ICD groups are assigned a priority allowing calls in higher priority groups to be
31. e Detection of IP GW Core data e Press the Reset Button Link Error Link error e Collect the log data of IP GW refer to the Installation Manual for IP GW card 310 Port Link Failure e Voice Processing System e Check the Voice Processing System malfunction e See if the corresponding optional e Ports defective on optional service card is installed properly service card DLC e Replace the corresponding optional service card 320 IP GW H 323 e Detection of IP GW H 323 e Replace the corresponding optional Dummy Call Test Dummy Call Test error service card Error e Collect the log data of IP GW refer to the Installation Manual for IP GW card 321 IP GW e Detection of Gatekeeper e Check the IP address setting of Gatekeeper Error access error Gatekeeper Check whether the Gatekeeper is connected to the network and work properly Check the route to the Gatekeeper 322 IP GW e Gatekeeper Registration is e Check the Gatekeeper setting Gatekeeper failed Registration Error 323 IP GW SDRAM Detection of IP GW SDRAM Replace the corresponding optional Failure error service card 324 IP GW DPRAM Detection of IP GW DPRAM e Replace the corresponding optional Failure error service card 325 IP GW LAN Chip Detection of IP GW LAN Chip Replace the corresponding optional Failure failure service card e Collect the log data of IP GW refer to the Installation Manual for IP GW card 326 IP GW Stop e IP GW is stopped from e Thi
32. only after all wiring is completed Mis wiring may cause the Hybrid IP PBX to operate improperly Refer to Section 2 Installation when wiring the system If an extension does not operate properly disconnect the telephone from the extension line and connect it again or turn off the Hybrid IP PBX using power switch then turn it on again For safety purposes this unit is equipped with a grounded plug If you do not have a grounded outlet please have one installed Do not bypass this safety feature by tampering with the plug Use twisted pair cable for CO line connection CO lines should be installed with surge protectors For details refer to 2 2 10 Surge Protector Installation To assure good quality telephone connection it is recommended new and modifications to existing installation of customer premise wiring shall use solid twisted pair copper conductors with minimum 24 gauge that comply with the electrical specifications for Category 3 wiring as detailed in ANSI EIA TIA 570A Building Wiring Standards Installation Manual 31 2 2 Installation of the Hybrid IP PBX 2 2 Installation of the Hybrid IP PBX 2 2 1 Unpacking Unpack the box and check the items below Main Unit 1 AC Cord 1 AC Adaptor 1 Screws for Wall Mounting 5 Washers for Wall Mounting 5 Mini Plug for pager and music source 2 SD Memory Card 1 Main Strap 1 Strap for the pre installed LCOT4 card 1 Optional C
33. position When the headset is not used select the HANDSET mode by Personal Programming The PT does not ring The ringer volume is off Turn on the ringer volume During a power failure extensions connected to ports 1 and 2 of super hybrid ports do not operate A DPT or APT is connected to the extension port The dialing mode tone or pulse is incorrect Disconnect the DPT or APT and connect an SLT Set the Tone Pulse switch to the other position Originating an outside call call transfer or conference cannot be performed The corresponding CO button does not exist on the PT Program the CO button Refer to 1 18 2 Flexible Buttons in the Feature Guide Cannot register the PS Wrong Personal Identification Number PIN is registered to the PS CS is not connected properly Register the PIN set to the Hybrid IP PBX into the PS Make sure that the cable is connected properly with correct pin assignments Also make sure that the cable does not make short circuits Switch all DIP switches off PS becomes out of range Cannot make calls using the PS CS is not working Location of CS is not good Access system of the PS is not properly set Make sure that the cable is connected properly with correct pin assignments Also make sure that the cable does not make short circuits Switch all DIP switches off Locate the CS properly refer to 2 7 5
34. reflected Window Glass Radio waves usually penetrate them Glass with wire nets Radio waves can penetrate them but tend to be reflected Glass covered with Radio waves are weakened considerably when they penetrate heat resistant film windows Floor Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are reflected Partition Steel Radio waves are reflected and rarely penetrate them Plywood Glass Radio waves usually penetrate them Column Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves tend to be reflected or diffracted Metal Radio waves tend to be reflected or diffracted Cabinet Steel Radio waves are usually reflected or diffracted and rarely penetrate them Wood Radio waves can penetrate them but they are weakened Installation Manual 91 2 7 Connection of 2 4 GHz Portable Stations CS Coverage Area The example below shows the size of the coverage area of 1 CS if it is installed where there is no obstacle Note Radio signal strength levels are measured during the site survey refer to 2 7 5 Site Survey Coverage Area Radio signal strength level is greater than 3 About 50 m to 60 m 164 ft to 197 ft Good Coverage Area Radio signal strength level is greater than 8 About 30 m to 40 m 98 ft to 131 ft Good conversation will be kept Gray Zone Conversation will be intermittent Out of
35. the MEC figures Calculation Example Equipment Type MEC Figure Pre installed Super Hybrid Ports 4 ports 4 KX T7600 series DPT 16 units 16 SLC4 2 cards 8 VPS 4 ports 4 Total 32 The total MEC figure is 32 As this exceeds 28 you need to install an MEC card for this configuration AC Adaptor Selection You must connect an additional AC adaptor in any of the following conditions e A total of more than 4 APTs DPTs except KX T7600 series and DSS consoles except KX T7600 series are connected e More than 4 CSs are connected e An MEC card is required to support a configuration with a total MEC figure exceeding 28 Installation Manual 27 1 4 Specifications Note For how to connect an AC adaptor or additional AC adaptor refer to 2 11 1 Starting the Hybrid IP PBX 28 Installation Manual Section 2 Installation This section describes the procedures to install the Hybrid IP PBX Detailed instructions for planning the installation site installing the optional service cards and cabling of peripheral equipment are provided Further information on system expansion and peripheral equipment installation is included Installation Manual 29 2 1 Before Installation 2 1 2 1 1 30 Before Installation Before Installation Please read the following notes concerning installation and connection before installing the Hybrid IP PBX and terminal equipment Be sure to comply with all applicable laws
36. 0 are recovered the ALARM indicator will turn off automatically indicating successful troubleshooting When other errors are logged the ALARM indicator will turn off only when the log for major or minor errors is cleared from the KX TDA50 Maintenance Console In other words the ALARM indicator will turn off under the following conditions e When the errors 021 091 092 and 510 are logged when the error conditions are recovered When other errors are logged when the log for major or minor errors is cleared from the KX TDA50 Maintenance Console Optional Service Card Initial Self Diagnosis Error Code Error Message PROBABLE CAUSE SOLUTION 212 Echo canceller e Optional service card e See if the corresponding optional access error malfunction ECHO service card is installed properly 216 MSG card DSP e Optional service card e Pulloutandre insertthe error malfunction MSG corresponding optional service card e Press the Reset Button e Replace the corresponding optional service card 217 MSG card data e Optional service card e See if the corresponding optional error malfunction MSG service card is installed properly e Erroneous recording of e Pull out and re insert the messages corresponding optional service card e Press the Reset Button e Re recordthe messages e Replace the corresponding optional service card System Start up and On line Operation Error Code Error Messa
37. 3 and 8 d Make sure that adjacent CS coverage areas overlap where the radio signal strength level is 8 by at least 5 m 16 ft e Make sure that the radio signal strength level is greater than 3 at any location within the service area demanded by the user 88 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations 4 Finish the site survey Refer to 2 7 6 After Site Survey a Return all DIP switches of each CS to the OFF position and stop supplying power b Turn off the PS 5 Connect the CS and PS to the Hybrid IP PBX and test the operation Refer to 2 7 7 Connecting a Cell Station to the Hybrid IP PBX a Connect the CSs to the Hybrid IP PBX b Register the PSs to the Hybrid IP PBX c Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 6 Mount the CS on the wall Refer to 2 7 8 Wall Mounting a Assuming everything goes as planned mount the CS on the wall Installation Manual 89 2 7 Connection of 2 4 GHz Portable Stations 2 7 3 Site Planning Choosing the best site for the CS requires careful planning and testing of essential areas The best location may not always be convenient for installation Read the following information before installing the unit Understanding the Radio Waves Characteristics of Radio Waves The transmission of radio waves and the CS coverage
38. 5PM MN ALM 392 10401 Clock master card selected L J Uo Ss l 1 2 3 4 5 6 Description Item Description 1 Date Date of the error detection 2 Time Time of the error detection 3 Level Major Alarm MJ ALM Errors that affect the whole system operation or result in system failure Minor Alarm MN ALM Errors that affect certain part of system operation 4 Error Code Three digit error code Installation Manual 141 4 1 Troubleshooting 142 Item Description 5 Sub Code Five digit sub code 1XXYY 1 Cabinet number XX Slot number 00 to 11 00 MPR 01 Super Hybrid Ports 02 to 11 Slots for optional service cards YY Physical port number 01 to 16 For optional service cards that are installed in Slots 08 to 11 sub slot number port number will be displayed Sub slot 1 11 to 14 Note When there is no parameter for slot and physical port number XX and YY will be displayed as 00 Example Sub code for MPR 10000 6 Error Message Error description Installation Manual 4 1 Troubleshooting List of Errors and Solutions The tables below list the errors and their solutions When an error whose error code is indicated with occurs in the Hybrid IP PBX the ALARM indicator on the front of the cabinet turns on red and the system logs the error information When the error conditions indicated by the error codes 021 091 092 and 51
39. 76 New Options 152 153 O Opening Closing the Covers 34 Operation 138 Options 21 Overview 87 124 P Parallel Connection of the Extensions 82 Paralleled Telephone Features 17 Password Security 127 PLC4 Card 66 PLC8 Card 69 Portable Station PS Features 17 Power Failure Connections 117 Procedure Overview 88 R Remote Card KX TDA5196 22 78 Removing Attaching the Front Cover 35 Revision History 152 RMT Card 78 S Safety Installation Instructions 30 SAFETY REQUIREMENTS 4 SD Memory Card 37 SD Memory Card for Software Upgrade to Enhanced Version KX TDA5920 22 37 Site Planning 90 Site Survey 96 SLC4Card 65 SLC8 Card 68 Slot Position 39 Slot Restrictions 39 Specifications 23 Starting the Hybrid IP PBX 118 Starting the KX TDA50 Maintenance Console and Assigning the Basic Items Quick Setup 128 Surge Protector Installation 56 System Capacity 26 System Components Table 2 System Connection Diagram 19 System Highlights 16 System Outline 15 T The Structure of this Manual 9 Troubleshooting 133 134 Troubleshooting by ErrorLog 141 Turning off the Hybrid IP PBX 121 Types of Connectors 49 U Unpacking 32 Using a Modular T Adaptor 82 84 Using an EXtra Device Port 83 Using the Reset Button 140 V Voice Mail Features 17 W Wall Mounting AC Adaptor 53 Wall Mounting CS 107 Wall Mounting KX TDA50 50 Wiring Precautions 30 Installation Manual 157 Index 158 Installation Manual
40. 84 264 First Party Call Control CTI Connection irc 86 2 7 Connection of 2 4 GHz Portable Stations c ceeceesesseeeeeeeeeeeeeeeeeseeeeeeeeeeensnneeeeneneeees 87 2 7 1 COEN 87 27 2 Proced re OVEIVIOW rientra 88 273 SICPENMNNilitll ai aaa 90 2 7 4 Before Site Survey lccleacaaiaaat 94 275 S te SUVy enrere K EKEK NRE E de E E KERERE ERE 96 27 6 After Site SUV lalla 100 2 7 7 Connecting a Cell Station to the Hybrid IP PBX 101 279 Wall MouUntiMg segetes ror ea a ses eet E eee 107 2 8 Connection of Doorphones Door Openers External Sensors and External Relays 109 2 8 1 Connection of Doorphones Door Openers External Sensors and External Relays 109 2 9 Connection OF Peripherals sata 113 2 9 1 Connection of Peripherals cates ceo hcg pao tee ce Sree ee a ai 113 2 10 Power Failure Connections uiii nnmnnn nnna 117 2 10 1 Power Failure Connections ea 117 2 11 Starting the Hybrid IP PBX ssicccisiscccscccstessceseseaneconsncccstcenisessecnaateresncnucedenie sexsecsnseaceseedees 118 2 41 1 Staring the Hybrid IP PBX sisarena e RN 118 3 Guide for the Hybrid IP PBX PC Programming Software 123 3 1 E asics secisccceasccccenencac ececucnneenesanueces cxnanceecncncccssanctecnceaiecacessccaseszaneceseeeansezeacneateexiase 124 dll Riccia 124 3 2 CONNEGOnitin ia 125 3 21 AONNEdioizaileiilaaaiaianaivali 125 3 3 Installation of the Hybrid IP PBX PC Programming Software
41. Board MPR 023 System data file e Old system files on SD e Restore the backup files version error Memory Card e Re installthe software 024 System e Defective system files on SD initialization file Memory Card version error 025 Card initialization file version error 026 LCD file version error 027 System data file checksum error 028 System initialization file checksum error 029 Card initialization file checksum error 030 LCD file checksum error Installation Manual 145 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 031 System data file e SD Memory Card not Press the Reset Button not found installed Reprogram the Hybrid IP PBX 032 System e Bad connection of SD Replace the SD Memory Card initialization file Memon Cate Replace the Hybrid IP PBX not found e SD Memory Card malfunction 033 Card initialization Main Board malfunction file not found 034 LCD file not found 035 System data file access error 036 System initialization file access error 037 Card initialization file access error 038 LCD file access error 039 SD file access error 041 Expansion e MEC card is not properly See if the corresponding optional Memory Card connected service card is installed properly Failure Pull out and re insert the corresponding optional service card Replace the corresponding optional service card 090 Over Card e Too many optional servic
42. CS No CS No 1 LEvEL 12 Press 1 9 and POWER 1t09 SAVE 0123456789 for more than 2 seconds To store the scan data gt Scan Data No 1 CS number and radio signal strength level 2 Scan data test result number Empty memory space will be indicated by a number stored memory space will be indicated by a Installation Manual 2 7 Connection of 2 4 GHz Portable Stations 2 Measure the radio signal strength by moving to and away from the CS a Move to the CS until the point the radio signal strength level becomes 12 b Move away from the CS and identify the CS coverage area within which the radio signal strength level is greater than 8 Draw the area on the map c Move away from the CS and identify the CS coverage area within which the radio signal strength level is greater than 3 Draw the area on the map PS CS NO 1 LEVEL 8 CS NO 1 LEVEL 3 Radio Signal Strength Levels Level 00 Out of range Level 01 to 02 Receives noise easily or disconnects Level 03 to 07 May receive noise Level 08 to 10 Good Level 11 to 12 Better 3 Repeat the steps 1 and 2 for other CSs and relocate the CSs when necessary a Overlap adjacent CS coverage areas where the radio signal strength level is 8 by 5 to 10 meters 16 to 33 feet 5mto10m 16 ft to 33 ft Installation Manual 97 2 7 Connection of 2 4 GHz Portable Stations b Overlap the CS c
43. E CHANGE PIN 01234 Using the KX TD7690 D b gt PIN for PS Registration gt S n Al Select da 1t04 ai CHANGE PIN o12 Installation Manual 105 2 7 Connection of 2 4 GHz Portable Stations PS Termination Confirm the following before canceling the PS registration e PS is turned on e PS is within the range 691 gt FSM gt gt 1 to 02 ENTER 001ta 028 ENTER i If Rejected or Time out is displayed CLEAR YES gt E p gt H E gt amp TothePs pp oc cc D operation Press CLEAR Press YES i sz below If the registration information is still stored in the PS Using the KX TD7680 gt DrOor Dror DD Select DELETE Select the Select YES SYSTEM desired item gt gt d C Tone Using the KX TD7690 CEL CEL gt gt gt amp Seo Select DELETE SI Select the SI Select YES SYSTEM desired item pr g C Tone Testing the Operation Walk around the service area while having a conversation using a registered PS If noise is frequent or conversations disconnect relocate the CSs or install an additional CS 106 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations 2 7 8 Wall Mounting 1 Place the reference for wall mounting on the following page on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Notes e Make sure that the screw heads are a
44. Installation Manual 2 4 Installation of the Extension Cards 2 4 Installation of the Extension Cards 2 4 1 HLC4 Card Function 4 port extension card for SLTs APTs DSS consoles a Voice Processing System VPS and PT interface CSs To extension Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Note For details about connecting the CS refer to 2 7 7 Connecting a Cell Station to the Hybrid IP PBX Pin Assignments RJ11 Connector Signal Name Function RITO D1 Data port High Li T Tip IL R Ring D2 Data port Low 1 The PT interface CS can be connected to the Hybrid IP PBX using a cable like a PT Installation Manual 63 2 4 Installation of the Extension Cards 2 4 2 DLC4 Card Function 4 port digital extension card for DPTs DSS consoles a VPS and PT interface CSs 1 To extension Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Note For details about connecting the CS refer to 2 7 7 Connecting a Cell Station to the Hybrid IP PBX Pin Assignments RJ11 Connector Signal Name Function D2 DI D1 Data port High ITI D2 Data port Low as Reserved 1 The PT interface CS can be connected to the Hybrid I
45. Installing the Doorphone KX T30865 1 Loosen the screw to separate the doorphone into 2 halves Installation Manual 109 2 8 Connection of Doorphones Door Openers External Sensors and External Relays 2 Pass the wires through the hole in the base cover and attach the base cover to a wall using 2 screws gt To terminal box Note Two kinds of screws are included with KX T30865 Please choose the appropriate kind for your wall type when a doorphone plate has been fixed to the wall ps when you wish to install the doorphone directly to the wall 3 Connect the wires to the screws located in the front cover gt To terminal box 4 Re attach the 2 halves and re insert the screw 110 Installation Manual 2 8 Connection of Doorphones Door Openers External Sensors and External Relays Connection of Doorphones 1 Connect DPH4 Card to the terminal boxes using telephone line cords Refer to 2 5 1 DPH4 Card for pin assignments 2 Connect the wires of doorphones 1 and 3 to the red and green screws on the terminal box 3 Connect the wires of doorphones 2 and 4 to the yellow and black screws on the terminal box To DPH4 card t Telephone Line Cord Doorphone 3 Doorphone 4 Telephone Line Cord
46. LAN to provide third party call control CTI The CTI connection uses the CSTA Phase 3 or TAPI 2 1 protocol Note The operating system of the PC or CTI server required for third party call control depends on your CTI application software For details refer to the manual for your CTI application software Pin Assignments No Signal Name a yo VBUS 3 4 2 USB D 3 USB D 4 GND Installation Manual 2 10 Power Failure Connections 2 10 Power Failure Connections 2 10 1 Power Failure Connections When the power supply to the Hybrid IP PBX fails power failure transfer PFT will switch from the current connection to the Power Failure Connection Refer to 2 4 1 Power Failure Transfer in the Feature Guide for further information Note If DC power is provided by backup batteries the Hybrid IP PBX will remain fully operational and the connection will not switch to the Power Failure Connection Using Analog CO Line Card and Super Hybrid Ports In the event of power failure SLTs connected to Ports 1 and 2 of the Super Hybrid Ports on the Main Board are automatically connected to PFT ports 1 and 2 of the first LCOT4 card installed in the least slot number Note Even when the power returns the conversation established during power failure will be maintained Installation Manual 117 2 11 Starting the Hybrid IP PBX 2 11 Starting the Hybrid IP PBX 2 11 1 Starting the Hybrid IP
47. P PBX using a cable like a PT 64 Installation Manual 2 4 Installation of the Extension Cards 2 4 3 SLC4 Card Function 4 port extension card for SLTs To extension Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Pin Assignments RJ11 Connector Signal Name Function RT T Tip LI TTT R Ring 4 1 a Reserved Installation Manual 65 2 4 Installation of the Extension Cards 2 4 4 PLC4 Card Function 4 port extension card for APTs DSS consoles and a VPS To extension Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Pin Assignments RJ11 Connector Signal Name Function D3 Di D1 Data port High RT T Tip i H R Ring 4 1 i D2 Data port Low 66 Installation Manual 2 4 Installation of the Extension Cards 2 4 5 DLC8 Card Function 8 port digital extension card for DPTs DSS consoles a VPS and PT interface CSs To extensions Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Note For details about connecting the CS refer to 2 7 7 Connecting a Cell Station to the Hybrid IP PBX Pin Assignments RJ11 Connector
48. Panasonic Hybrid IP PBX Installation Manual Model No KX T DA50 SLL Atte N N N N N N NIN N N IN N IN N N K Thank you for purchasing a Panasonic Hybrid IP PBX SD Please read this manual carefully before using this product and save this manual for future use i SD Logo is KX TDA50 MPR Version 2 0 a trademark System Components System Components Table Model Description Main Unit KX TDA50 Main Unit CO Line Cards KX TDA5180 4 Port Analog Trunk Card LCOT4 KX TDA5193 4 Port Caller ID Card CID4 KX TDA5480 4 Channel VoIP Gateway Card IP GW4 Extension Cards KX TDA5170 4 Port Hybrid Extension Card HLC4 KX TDA5171 4 Port Digital Extension Card DLC4 KX TDA5172 8 Port Digital Extension Card DLC8 KX TDA5173 4 Port Single Line Telephone Extension Card SLC4 KX TDA5174 8 Port Single Line Telephone Extension Card SLC8 KX TDA5175 4 Port Proprietary Extension Card PLC4 KX TDA5176 8 Port Proprietary Extension Card PLC8 Other Cards KX TDA5105 Memory Expansion Card MEC KX TDA5161 4 Port Doorphone Card DPH4 KX TDA5166 8 Channel Echo Canceller Card ECHO8 KX TDA5168 Extension Caller ID Card EXT CID KX TDA5191 2 Channel Message Card MSG2 KX TDA5196 Remote Card RMT Optional SD Memory Card KX TDA5920 SD Memory Card for Software Upgrade to Enhanced Version Cell Station CS KX T0141 2 Channel Cell Station Unit for 2 4 GHz Portable Stati
49. Service Cannot make receive calls Radio Signal Strength Levels Level 00 Out of range Level 01 to 02 Receives noise easily or disconnects Level 03 to 07 May receive noise Level 08 to 10 Good Level 11 to 12 Better Site Survey Preparation 1 Obtain the map and investigate the installation site a Check the obstacles e g shelves columns and partitions b Check the materials of the structures e g metal concrete and plywood c Check the layout and dimensions of the room corridor etc d Write down the above information to the map 2 Examine the service area demanded by the user on the map referring to the following example a Draw the coverage area around a CS Extend the coverage area to 30 to 60 meters 98 to 197 feet in one direction depending on the materials of the building structures and obstacles in the installation site Note that a CS cannot be installed outside a building b If one CS cannot cover the entire service area install additional CSs as required Overlap the coverage areas of adjacent CSs Where CS coverage areas overlap the PS will start call handover to the next CS if the signal from 92 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations one CS becomes weak However if a PS moves away from a CS and there are no CSs available for handover the PS may go out of range and the call could be lost If the signal from the CS fades due to the structure of the buildin
50. T MAY ONLY BE INSTALLED AND SERVICED BY QUALIFIED SERVICE PERSONNEL e IF DAMAGE TO THE UNIT EXPOSES ANY INTERNAL PARTS DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THE UNIT TO YOUR DEALER e UNPLUG THIS UNIT FROM THE AC OUTLET IF IT EMITS SMOKE AN ABNORMAL SMELL OR MAKES UNUSUAL NOISE THESE CONDITIONS CAN CAUSE FIRE OR ELECTRIC SHOCK CONFIRM THAT SMOKE HAS STOPPED AND CONTACT AN AUTHORIZED PANASONIC FACTORY SERVICENTER e WHEN RELOCATING THE EQUIPMENT FIRST DISCONNECT THE TELECOM CONNECTION BEFORE DISCONNECTING THE POWER CONNECTION WHEN THE UNIT IS INSTALLED IN THE NEW LOCATION RECONNECT THE POWER FIRST AND THEN RECONNECT THE TELECOM CONNECTION e TO PREVENT POSSIBLE FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE e THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE ENSURE THAT THE AC OUTLET IS LOCATED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE CAUTION DANGER OF EXPLOSION EXISTS IF A BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE BATTERY MANUFACTURER DISPOSE OF USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS Installation Manual 7 When you ship the product Carefully pack and send it prepaid adequately insured and preferably in the original carton Attach a postage paid letter detailing the symptom to the outside of the carton DO NOT send the product to the Executive or Regional Sales offices They are NOT equ
51. adio frequency energy The unit operates in the frequency range of 2401 MHz to 2480 MHz and the power output level can range from 0 004 W to 0 4 W Do not use the unit in health care facilities if any regulations posted in the area instruct you not to do so Hospitals or health care facilities may be using equipment that could be sensitive to external RF radio frequency energy Installation Manual Table of Contents 1 SySstemOUuiine a i see recat te cetendsvctceseentwemstsiceciecesteattecdeadsostuetececsnsxend 15 1 1 System Highlights aiar 16 1 1 1 System Highlights osc tas ei 16 1 2 Basic System Constilcelioni aisi 18 2 50 Mam UN eee E E EE vechaezinaeeesndeae cers 18 1 2 2 System Connection DIagrams clc aliene 19 1 3 INS e E E E E cde enc TT 21 ist Held 21 1 4 SPEciticati0ONS uccl cca 23 1 41 General Descriplion aaa 23 14 2 Characteristics 25 1 4 3 System Capaccio 26 2 oi Eio a P iano 29 2 1 Before Installation ai 30 2 1 1 Before Installation cece eee e ee eect eee eee ered ee ee eet i Eiane eni n aek Eaa aRt 30 2 2 Installation of the Hybrid IP PBX sscccceessssessenseeeeeeeeeesseeneeeeeeeensnseeeeneeeeeeeseeeesnenoes 32 221 Uil 32 2 2 2 NamesandLocations eee eee e eee tennt anartan naera rrer egtggeeeeeeneeseeeeeeeeeseeees 33 22 93 Opening Closing the Covers css ss we steered ed alata capes ute ela 34 2 2 4 Installation of the SD Memor
52. allation of the Hybrid IP PBX Connector Type Pin Number Used for RJ11 Twisted pair cable DPH4 KX TDA5161 HLC4 KX TDA5170 DLC4 KX TDA5171 DLC8 KX TDA5172 SLC4 KX TDA5173 SLC8 KX TDA5174 PLC4 KX TDA5175 PLC8 KX TDA5176 LCOTA KX TDA5180 Super Hybrid Ports Main Board TTT 1 8 IP GW4 KX TDA5480 Twisted pair cable 10 pin 8 pin DPH4 KX TDA5161 Terminal Block Terminal Block 1 ie tti 8 7 ANZI Main Board 1 5 6 9 USB Main Board DI 2 PD 3 4 N n Main Board Pager port MOH port Mini Plug I A Installation Manual 49 2 2 Installation of the Hybrid IP PBX 2 2 8 Wall Mounting KX TDA50 Mounting on Wooden Wall 1 Place the reference for wall mounting on the last page of this manual on the wall to mark the three screw positions 130 mm 5 1 8 in 250 mm 9 13 16 in 2 Install the screws and washers included in the wall Washer Drive the screw to this position Notes e Make sure that the screw heads are at the same distance from the wall e Install the screws perpendicular to the wall 3 Hook the main unit on the screw heads 3A pk il cae Wile
53. answered before calls in lower priority groups Computer Telephony Integration CTI Features Computers can be connected to the Hybrid IP PBX to provide extension users with access to advanced features such as pop up display of caller information computer based speed dialing etc PC Phone PC Console These Panasonic CTI applications can be used on computers connected to each extension providing their respective extension users with powerful and flexible call handling and display features 16 Installation Manual 1 1 System Highlights Third Party CTI Applications The Hybrid IP PBX supports industry standard protocols allowing third party CTI applications to be integrated with the Hybrid IP PBX and its extensions Voice Mail Features A Voice Processing System VPS can be connected to the Hybrid IP PBX to provide Voice Mail VM and Automated Attendant AA services A Panasonic VPS which supports DPT Digital Integration can be connected to the Hybrid IP PBX effortlessly and with minimal setup required Conventional DTMF analog voice mail systems including those from other manufacturers are also supported Paralleled Telephone Features By connecting telephones in parallel you can increase the number of telephones connected to the Hybrid IP PBX without adding additional extension cards Parallel Mode An SLT can be connected to an APT or DPT which is connected to a Super Hybrid Port of the Hybrid IP PBX The SLT shares th
54. ard Label Sheet 1 32 Installation Manual 2 2 Installation of the Hybrid IP PBX 2 2 2 Names and Locations DC IN 2 DCIN 1 Power Switch gs gt SD Memory Card Slot Cover Reset Button System Initialize Switch Super Hybrid Ports RS 232C port r USB port Installation Manual 33 2 2 Installation of the Hybrid IP PBX 2 2 3 Opening Closing the Covers Opening the Covers 1 Pull the slide button to the right and holding it slide the cable cover upwards Then turn the cable cover slightly to remove it Cable Cover 2 Remove the three screws 34 Installation Manual 2 2 Installation of the Hybrid IP PBX Removing Attaching the Front Cover If you prefer you can remove the front cover Removing the Front Cover Holding the front cover open at about a 45 angle remove the front cover by pushing it in the direction of the arrow as shown below Attaching the Front Cover Fit the front cover to the main unit as shown below and then close the front cover Installation Manual 35 2 2 Installation of the Hybrid IP PBX Closing the Covers 1 Close the front cover then tighten the three screws 2 Attach the rear hooks on the cable cover to the main unit then swing the cable cover closed so
55. area depend on the structure and materials of the building Office equipment such as computers and fax machines can interfere with radio waves Such equipment may create noise or interfere with the performance of the PS The illustration below shows the special transmitting patterns of radio waves 1 Radio waves are reflected by objects such as those made of metal 2 Radio waves are diffracted by objects such as metallic columns 3 Radio waves penetrate objects such as those made of glass 1 Reflection CS Column 2 Diffraction 3 Penetration Relationships Between Radio Waves and Building Structure and Materials e The CS coverage area is affected more by the building materials and their thickness than the number of obstacles e Radio waves tend to be reflected or diffracted by conductive objects and rarely penetrate them e Radio waves tend to penetrate insulated objects and are rarely reflected by them e Radio waves penetrate thin objects more than thick objects e The table below shows the transmission tendency of radio waves when they reach objects made from various materials 90 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations Object Material Transmission Tendency Wall Concrete The thicker they are the less radio waves penetrate them Ferroconcrete Radio waves can penetrate them but the more iron there is the more radio waves are
56. culation Example 27 Changed Contents 152 153 Characteristics 25 CID4 Card 60 Computer Telephony Integration CTI Features 16 Confirming the CO Line Connection 121 Connecting a Cell Station to the Hybrid IP PBX 101 Connection 125 136 Connection Diagram for External Sensors and External Relays 72 Connection of 2 4 GHz Portable Stations 87 Connection of Doorphones Door Openers External Sensors and External Relays 109 Connection of Extensions 80 Connection of Peripherals 113 Construction of Main Unit 18 CTl First Party Call Control 86 CTI Third Party Call Control 116 D Digital EXtra Device Port Digital XDP Connection 84 Digital XDP 82 84 DLC4Card 64 DLC8 Card 67 Door Opener 70 109 Doorphone 70 109 DPH4 Card 70 156 Installation Manual E ECHO8 Card 73 EXT CID Card 75 Extension Caller ID Card KX TDA5168 21 75 External Relay 70 109 External Sensor 70 109 EXtra Device Port XDP Mode 82 84 F First Party Call Control CTI Connection 86 Frame Ground Connection 38 G General Description 23 Guide for the Hybrid IP PBX PC Programming Software 123 H Handling of the Cables 45 HLC4 Card 63 Hospitality Features 17 Installation 29 Installation of the CO Line Cards 59 Installation of the Extension Cards 63 Installation of the Hybrid IP PBX 32 Installation of the Hybrid IP PBX PC Programming Software 127 Installation of the Other Cards 70 Installation of the SD Memory Card 37 In
57. d IP PBX and PC Pin Assignments Circuit Type No Signal Name Function EIA CCITT i i 2 RD RXD Receive Data BB 104 3 SD TXD Transmit Data BA 103 a 4 ER DTR Data Terminal Ready CD 108 2 5 SG Signal Ground AB 102 6 DR DSR Data Set Ready CC 107 7 RS RTS Request To Send CA 105 8 CS CTS Clear To Send CB 106 Connection Charts For connecting a printer PC with a 9 pin RS 232C connector Hybrid IP PBX Printer PC Creutt Type Signal pin No Pino Signa Circuit Type BB RD RXD 2 2 RD RXD BB BA SD TXD 3 Gal 3 SD TXD BA CD ER DTR 4 4 ER DTR CD AB SG 5 5 SG AB CC DR DSR 6 6 DR DSR CC CA RS RTS 7 7 RS RTS CA CB CS CTS 8 7 dA 8 CS CTS CB 114 Installation Manual 2 9 Connection of Peripherals For connecting a printer PC with a 25 pin RS 232C connector Hybrid IP PBX Printer PC Circuit Type Signal Signal Circuit Type EIA Name Pin No Pin No Name EIA BB RD RXD 2 1 FG AA BA SD TXD 3 3 RD RXD BB CD ER DTR 4 2 SD TXD BA AB SG 5 20 ER DTR CD CC DR DSR 6 7 SG AB CA RS RTS 7 5 CS CTS CB CB CS CTS 8 Ma i 6 DR DSR CC 4 RS RTS CF RS 232C Signals Receive Data RXD input Conveys signals from the printer or the PC Transmit Data TXD output Conveys signals from the unit to the printer or the PC A Mar
58. dition that needs to be solved However if this is logged frequently with 305 Data Link failure check the connection as it may not be done properly 392 Clock mastercard e Clock master card has been e Check if the proper card is selected as selected changed to the one indicated the new clock master card by the sub code 393 LAN Carrier e IP GWcardconnectedto the e This information is logged when detected LAN synchronization of LAN is established 394 IP GW Core Data e IP GW Core Data Link e This information is logged when IP GW Link established established Core Data Link is recovered 148 Installation Manual 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 395 IP GW e Connection to the e This information is logged when Gatekeeper Error Gatekeeper is recovered connection to the Gatekeeper is Cleared recovered 396 IP GW Run e IP GWis started from remote e This information is logged when IP GW maintenance PC is started from remote maintenance PC 510 SMDR disconnect RS 232C cable not e Check the RS 232C cable connected Breaking of RS 232C cable Printer terminal equipment malfunction Check the terminal equipment Installation Manual 149 4 1 Troubleshooting 150 Installation Manual Section 5 Appendix Installation Manual 151 5 1 Revision History 5 1 Revision History 5 1 1 MPR Version 1 1 New Options e System Components Table
59. e 38 To ground For grounding wire green and yellow insulation is required and the cross sectional area of the conductor must be more than 0 75 mm or 18 AWG e Be sure to comply with applicable local regulations e g law guidelines e Proper grounding connection to ground is very important to protect the Hybrid IP PBX from the bad effects of external noise or to reduce the risk to the user of electrocution in the case of a lightning strike e The ground wire of the AC cable has an effect against external noise and lightning strikes but it may not be enough to protect the Hybrid IP PBX A permanent connection between ground and the ground terminal of the Hybrid IP PBX must be made In most of the continental United States the ground provided by the Third wire ground at the commercial power outlet will be satisfactory However in a small percentage of cases this ground may be installed incorrectly Therefore the following test procedure should be performed Test Procedure 1 2 3 Obtain a suitable voltmeter and set it for a possible reading of up to 250 V AC Connect the meter probes between the 2 main AC voltage points on the wall outlet The reading obtained should be 108 V AC to 132 V AC Move one of the meter probes to the 3rd prong terminal GND Either the same reading or a reading of 0 volt should be obtained If a reading of 0 volt at one terminal and a reading of 108 V AC to 132 V AC at the
60. e CS should be kept free of dust moisture high temperature more than 40 C 104 F low temperature less than 0 C 32 F vibration and should not be exposed to direct sunlight The CS should not be placed outdoors use indoors The CS should not be placed near high voltage equipment The CS should not be placed on a metal object Systems using 2 4 GHz ISM Industrial Scientific and Medical band may interfere with the KX TDA wireless system Examples of such systems are cordless telephones wireless LAN Home RF microwave ovens and other ISM devices These systems may cause minor noise Keeping some distance between the equipment listed below may prevent interference The distance may vary depending on the environment Equipment Distance CS and office equipment such as a computer telex fax More than 2 m 6 ft 7 in machine etc CS and PS More than 1 m 3 ft 3 in Each PS More than 0 5 m 1 ft 8 in Hybrid IP PBX and CS More than 2 m 6 ft 7 in CS and CS More than 15 m 49 ft Please take into consideration the distance between the CSs when site planning Please consult a certified dealer for details However the required distance between CSs may vary depending on the environment of the installation site and conditions in which the wireless system is used Conduct the site survey to determine the appropriate distance Installation Manual 87 2 7 Connection of 2 4 GHz Portable Sta
61. e Reduce the number of optional service Limitation cards installed cards 091 PT connection e Too many PTs connected Reduce the number of PTs over 092 CS connection e Too many CSs connected Reduce the number of CSs over 234 DPLL clock failure e Optional service card See if the corresponding optional malfunction DLC IP GW service card is installed properly e Main Board malfunction Pull out and re insert the corresponding optional service card Press the Reset Button Replace the corresponding optional service card Replace the Hybrid IP PBX 251 MSG DSP failure e Optional service card See if the corresponding optional malfunction MSG service card is installed properly Replace the corresponding optional service card 146 Installation Manual 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 305 Data Link failure e Data link between the CS and e Check the connection between the CS Hybrid IP PBX failed and Hybrid IP PBX e Data link between the e Check the connection between the network and IP GW card network and IP GW card failed 307 LAN No Carrier e IP GW card not connected to e Check the connection between the the LAN LAN and IP GW card 308 IP GW LAN Loop e Detection of IP GW LAN e Replace the corresponding optional back Error Loop back Test error service card e Collect the log data of IP GW refer to the Installation Manual for IP GW card 309 IP GW Core Data
62. e same extension number with the APT or DPT EXtra Device Port XDP Mode An SLT can be connected to a DPT which is connected to a Super Hybrid Port of the Hybrid IP PBX Unlike parallel mode XDP mode allows each telephone to act as an independent extension with its own extension number Digital XDP A DPT can be connected to another DPT which is connected to a DPT port or a Super Hybrid Port of the Hybrid IP PBX Similar to XDP mode each DPT acts as an independent extension with its own extension number Portable Station PS Features A Panasonic PS can be used in place of a PT to provide wireless access to PBX features and call handling When in Wireless XDP Parallel Mode a PS can share an extension number with a wired telephone allowing extension users to use their PSs when they are away from their desks to answer or make calls as if they were using their wired telephones Hospitality Features This Hybrid IP PBX has several features that support its use in a hotel type environment Extensions corresponding to guest rooms can be checked in or checked out by a designated hotel operator who can also check or set wake up calls Installation Manual 17 1 2 Basic System Construction 1 2 Basic System Construction 1 2 1 Main Unit The main unit is equipped with 4 analog trunk ports one LCOT4 card and 4 extension ports Super Hybrid Ports For system expansion optional service cards can be installed and an additional AC ada
63. ener 1 com Relay 1 com OP2a RL2a ORA OP2b RL2b Door opener 2 Relay 2 lil OP2a RL2a Door opener 2 com Relay 2 com i ERRATA 0 OP3b RL3b Door opener 3 Relay 3 OP3a RL3a Door opener 3 com Relay 3 com OP4b RL4b Door opener 4 Relay 4 OP4a RL4a Door opener 4 com Relay 4 com Reserved Installation Manual 71 2 5 Installation of the Other Cards Connection Diagram for External Sensors and External Relays Power to the external sensor is provided from the DPH4 card and must be grounded through the DPH4 card as indicated in the diagram below A pair of sensor and common lines must be connected to the DPH4 card for each external sensor The Hybrid IP PBX detects input from the sensor when the signal is under 100 Q E sensor g e Sensor 4 A common ai 4 7 e a rere aaa _ sensor 6 A l ZI i nsor Sensor 3 common 5 a OE sensor i 2 ATTS Sensor 2 fi common e __ sensor 2 Sensor 1 ci common 1 e oO 0 e 0 e 0 e e N 0 Aa 0 DO NY CO O 72 Installation Manual 2 5 Installation of the Other Cards 2 5 2 ECHO8 Card Function 8 channel card for echo cancellation during conferences Accessories and User supplied Items
64. essive input level from external music source Decrease the output level of the external music source by using the volume control on the music source Alternate Calling Ring Voice and Live Call Screening LCS do not function as set when using a Wireless Phone KX T7880 KX T7885 KX TD7894 KX TD7895 Voice calling mode and Hands free mode with LCS are not available with Wireless Phones Switch the calling mode to ring calling Set the LCS mode to Private 134 Installation Manual 4 1 Troubleshooting PROBLEM PROBABLE CAUSE SOLUTION The ALARM indicator on the A major system error occurs in See the error log using the KX TDA50 front of the cabinet turns on red the Hybrid IP PBX Maintenance Console refer to 4 1 5 Troubleshooting by Error Log Installation Manual 135 4 1 Troubleshooting 4 1 2 Connection Connection between the Hybrid IP PBX and a PT C dial No CAUSE SOLUTION an you dia an a The T R is connected to the D1 D2 Use the correct cord the inner 2 wires are for T R and D1 D1 the outer 2 wires are for T T D1 D2 R R D2 D2 Hybrid IP PBX Extension Connection between the Hybrid IP PBX and an SLT CAUSE SOLUTION The T R is connected to the D1 D2 Use the correct cord the inner 2 wires are for T R DIO o e If a telephone equipped Te_ with an A A1 relay is R er A D2 Se connected to the Hyb
65. f ground rod and the required depth depend on the composition of the soil 58 Installation Manual 2 3 Installation of the CO Line Cards 2 3 Installation of the CO Line Cards 2 3 1 LCOT4 Card Function 4 port analog CO line card with 2 power failure transfer PFT ports One CID4 card can be mounted on the LCOT4 card refer to 2 3 2 CID4 Card PFT Port 2 PFT Port 1 RJ11 lt AT e To CO line Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 User supplied not included RJ11 connector Notes e To confirm the CO line connection refer to Confirming the CO Line Connection in 2 11 1 Starting the Hybrid IP PBX e For details about power failure transfer refer to 2 10 1 Power Failure Connections Pin Assignments RJ11 Connector Signal Name Function TR R Ring LI rT u Tip 4 1 Reserved Installation Manual 59 2 3 Installation of the CO Line Cards 2 3 2 CID4 Card Function 4 port Caller ID signal type FSK FSK with Call Waiting Caller ID Visual Caller ID DTMF To be mounted on the LCOT4 card CID4 Card LCOT4 Card Accessories and User supplied Items Accessories included none User supplied not included none Note If you need to remove the CID4 card 60 Installation Manual 2 3 Installation of the CO Line Cards 2 3 3 IP GW4 Card Function 4 channel VoIP gateway card
66. ferences KX TDA5168 Extension Caller ID Card Sends Caller ID signals to extension ports 1 EXT CID KX TDA5170 4 Port Hybrid Extension 4 port extension card for SLTs APTs DSS 1 Card HLC4 consoles a Voice Processing System VPS and PT interface CSs KX TDA5171 4 Port Digital Extension 4 port digital extension card for DPTs DSS 1 Card DLC4 consoles a VPS and PT interface CSs 1 KX TDA5172 8 Port Digital Extension 8 port digital extension card for DPTs DSS 2 Card DLC8 consoles a VPS and PT interface CSs KX TDA5173 4 Port Single Line 4 port extension card for SLTs 1 Telephone Extension Card SLC4 KX TDA5174 8 Port Single Line 8 port extension card for SLTs 2 Telephone Extension Card SLC8 KX TDA5175 4 Port Proprietary 4 port extension card for APTs DSS consoles 1 Extension Card PLC4 and a VPS KX TDA5176 8 Port Proprietary 8 port extension card for APTs DSS consoles 2 Extension Card PLC8 and a VPS KX TDA5180 4 Port Analog Trunk Card 4 port analog CO line card with 2 power failure 2 2 LCOT4 transfer PFT ports KX TDA5191 2 Channel Message Card 2 channel message card 2 MSG2 KX TDA5193 4 Port Caller ID Card 4 port Caller ID signal type FSK FSK with Call 3 CID4 Waiting Caller ID Visual Caller ID DTMF To be mounted on the LCOT4 card Installation Manual 21 1 3 Options iui Maximum Model No Model Name Description Quantity KX TDA5196 Remote Card
67. g there may be some handover delay The user will hear a range warning before handover in this case This also applies in the case of interference from 2 4 GHz apparatus Example Installing in a Room Separated by Walls Things to take note of e The room is separated by walls e The room is surrounded by concrete walls CS installation plan e The coverage area of each CS will not extend as far as when there is no obstacle because the radio signals will be weakened by separating walls Therefore you will need 5 CSs to cover the entire room lt lt 150 m 492 ft aH 70m 230 ft Installation Manual 93 2 7 Connection of 2 4 GHz Portable Stations 2 7 4 Before Site Survey Setting and Installing the CS Temporarily for Site Survey 1 Switch the Radio Signal Test switch from OFF to ON 2 Set the CS number switches as desired DIP Switch OFF ON l Radio Signal li ert Test Switch CSno 1 CSno2 CSno 3 CSno 4 CSno 5 CSno 6 CSno 7 CSno 8 CSno 9 E E E H Les oO n E 2 E 3 E 4 N e To see the radio signal strength of more than 1 CS a CS number must be set for each CS e f more than 1 CS is in Radio Signal Test mode each CS must have a unique CS number 94 Installation Manual 2 7 Connection of 2 4
68. ge PROBABLE CAUSE SOLUTION 000 MPR WDT e Main Board MPR e Press the Reset Button overflow malfunction e Reprogram the Hybrid IP PBX 001 SDRAM bit error Erroneous processing of e Replace the Hybrid IP PBX Main Board MPR software e Software error due to external factors Installation Manual 143 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 002 System Reset Reset Button is pressed Power failure Main Board malfunction Erroneous processing of Main Board software Software error due to external factors Ignore if not frequent Press the Reset Button Reprogram the Hybrid IP PBX Replace the Hybrid IP PBX additional AC cord 010 AC power down AC power down e Check the power supply system Bad connection or breaking of e See if the AC cord is connected AC cord properly e Check the AC cord e Replace the AC cord be sure to turn off the Hybrid IP PBX when replacing 011 DC power down AC power down e Check the power supply system Power supply circuit Main e See if the AC cord is connected Board malfunction properly Detection of over current e Check the AC cord short circuit on optional e Replace the AC cord be sure to turn service cards off the Hybrid IP PBX when replacing e Replace the Hybrid IP PBX e Remove the optional service cards and restart the Hybrid IP PBX 012 MPR RAM Battery out e Replace the Hybrid IP PBX battery l
69. h of the external modem to ON then the external modem will be initialized with the default values The following AT command settings may be required for the modem e The Data Terminal Ready DTR signal should be ignored e The Data Terminal Equipment DTE Modem flow control should be turned off e The data compression should be disabled e Error Correction is not necessary e Use an RS 232C straight cable for connection between the Hybrid IP PBX and external modem e An AT command for initialization enabling automatic answer etc can only be programmed by KX TDA50 Maintenance Console AT amp FOQOEOV1S0 1X0 amp DO is stored as the default value For more information about the AT command refer to the external modem s instructions 126 Installation Manual 3 3 Installation of the Hybrid IP PBX PC Programming Software 3 3 Installation of the Hybrid IP PBX PC Programming Software 3 3 1 Installing and Starting the KX TDA50 Maintenance Console System Requirements Operating System e Microsoft Windows 98 SE Windows Me Windows 2000 or Windows XP Hardware e CPU Intel Pentium 133 MHz or better microprocessor e RAM at least 64 megabytes MB of free RAM 128 MB recommended e HDD at least 100 MB of hard disc space Password Security Warning to the Administrator or Installer regarding the system password 1 Please provide all system passwords to the customer 2 To avoid una
70. ing 4 1 1 Installation PROBLEM PROBABLE CAUSE SOLUTION Extension does not operate Bad extension card Exchange the card for a known working one Bad connection between the Hybrid IP PBX and telephone Take the telephone and plug it into the same extension port using a short telephone cord If the telephone works then the connection between the Hybrid IP PBX and the telephone must be repaired A telephone with an A A1 relay is connected Use a 2 wire cord Set the A A1 relay switch of the telephone to the OUT or OFF position Bad telephone Take the telephone and plug it into another extension port that is working If the telephone does not work replace the telephone The number of terminal equipment exceeds the capacity of the Hybrid IP PBX with the supplied AC adaptor only Connect an additional AC adaptor The Hybrid IP PBX does not operate properly Press the Reset Button refer to 4 1 4 Using the Reset Button Turn off the power switch and then turn it back on Turn off the power switch and then unplug the Hybrid IP PBX After 5 minutes plug the Hybrid IP PBX back in and turn the power switch back on Noise on external paging Induced noise on the wire between the Hybrid IP PBX and the amplifier Use a shielded cable as the connection wire between the Hybrid IP PBX and amplifier A short shielded cable is recommended Distorted external music Exc
71. ing sound 76 Installation Manual 2 5 Installation of the Other Cards Removing the MEC Card Pull open the guide rails using a flathead screwdriver and while holding them open remove the MEC card Installation Manual 77 2 5 Installation of the Other Cards 2 5 6 RMT Card Function Analog modem card for remote communication with the Hybrid IP PBX ITU T V 90 support RMT Card RMT Slot Accessories and User supplied Items Accessories included none User supplied not included none CAUTION Make sure to insert the RMT card between the guide rails until it locks into the RMT slot Push the card firmly into place until you hear a clicking sound 78 Installation Manual 2 5 Installation of the Other Cards Removing the RMT Card Pull open the guide rails using a flathead screwdriver and while holding them open remove the RMT card Installation Manual 79 2 6 Connection of Extensions 2 6 Connection of Extensions 2 6 1 Maximum Cabling Distances of the Extension Wiring Twisted Cable Cable Maximum Distance 26 AWG 222 m 728 ft Parae SS 24 AWG 347 m 1138 ft i 22 AWG 500 m 1640 ft i CAT 5 347 m 1138 ft a a KX T7600 Series i Cable Maximum Distance 26 AWG 500 m 1640 ft 24 AWG 720 m 2362 ft 22 AWG 830 m 2723 ft CAT 5 720 m 2362 ft i e KX T7600 Series Cable Maximum Distance i Master DPT on the 26 AWG 380 m
72. ipment installation is included Section 3 Guide for the Hybrid IP PBX PC Programming Software Explains the installation procedure structure and basic information of the KX TDA50 Maintenance Console Section 4 Troubleshooting Provides information on the Hybrid IP PBX and telephone troubleshooting About the Other Manuals Along with this Installation Manual the following manuals are available Feature Guide Describes all basic optional and programmable features of the Hybrid IP PBX and step by step instruction for performing system programming using a proprietary telephone or a personal computer PC User Manual Provides operating instructions for end users using a PT SLT PS or DSS Console Trademarks e Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries e Intel and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries e All other trademarks identified herein are the property of their respective owners e Screen shots reprinted with permission from Microsoft Corporation Installation Manual 9 F C C REQUIREMENTS AND RELEVANT INFORMATION 10 Notification to the Telephone Company This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA On the side of this equipment is a label that contains among other informati
73. ipped to make repairs Product Service Panasonic Factory Servicenters for this product are listed in the servicenter directory Consult your certified Panasonic dealer for detailed instructions For Future Reference Please print record and retain the following information for future reference Note The serial number of this product can be found on the label affixed to the unit You should record the model number and the serial number of this unit as a permanent record of your purchase to aid in identification in the event of theft MODEL NO SERIAL NO DATE OF PURCHASE NAME OF DEALER DEALER S ADDRESS DEALER S TEL NO 8 Installation Manual Introduction This Installation Manual is designed to serve as an overall technical reference for the Panasonic Hybrid IP PBX KX TDA50 It provides instructions for installing the hardware and programming the Hybrid IP PBX using the KX TDA50 Maintenance Console The Structure of this Manual This manual contains the following sections Section 1 System Outline Provides general information on the Hybrid IP PBX including the system capacity and specifications Section 2 Installation Describes the procedures to install the Hybrid IP PBX Detailed instructions for planning the installation site installing the optional service cards and cabling of peripheral equipment are provided Further information on system expansion and peripheral equ
74. ired But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary Changes in Telephone Company Communications Facilities Equipment Operations and Procedures The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service Trouble with this equipment If trouble is experienced with this equipment for repair or warranty information please see the attached warranty which includes the Servicenter Directory If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Connection to Party Line Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Installation Manual 7 Combined Use with Alarm Equipment If your home has specially wired alarm equipment connected to the telephone line ensure the installation of this equipment does not disable your alarm equipment If you have questions about what will disable alarm equipment consult your telephone company or a qua
75. k condition is held unless data or BREAK signals are being transmitted Data Terminal Ready DTR output This signal line is turned ON by the unit to indicate that it is ON LINE Circuit ER DTR ON does not indicate that communication has been established with the printer or the PC It is switched OFF when the unit is OFF LINE Signal Ground SG Connects to the DC ground of the unit for all interface signals Data Set Ready DSR input An ON condition of circuit DR DSR indicates the printer or the PC is ready Circuit DR DSR ON does not indicate that communication has been established with the printer or the PC Request To Send RTS output This lead is held ON whenever DR DSR is ON Clear To Send CTS input An ON condition of circuit CS CTS indicates that the printer or the PC is ready to receive data from the unit The unit does not attempt to transfer data or receive data when circuit CS CTS is OFF Frame Ground FG Connects to the unit frame and the earth ground conductor of the AC power cord Installation Manual 115 2 9 Connection of Peripherals 116 PC CTI Server via USB version 1 1 The Hybrid IP PBX is equipped with a USB interface This interface provides communication between the Hybrid IP PBX and a PC or a CTI server The PC is used for system programming diagnostics and external system database storage save load functions The CTI server is used for connecting PCs on a
76. lified installer Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this device When programming emergency numbers and or making test calls to emergency numbers 1 Remain on the line and briefly explain to the dispatcher the reason for the call before hanging up 2 Perform such activities i
77. n the off peak hours such as early morning hours or late evenings WARNING The software contained in the ARS and TRS features to allow user access to the network must be upgraded to recognize newly established network area codes and exchange codes as they are placed into service Failure to upgrade the on premise PBXs or peripheral equipment to recognize the new codes as they are established will restrict the customer and users of the PBX from gaining access to the network and to these codes KEEP THE SOFTWARE UP TO DATE WITH THE LATEST DATA Installation Manual 11 12 For Cell Station CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void user s authority to operate this device Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encou
78. nce 15 000 Q minimum Maximum Number of Extension Instruments per Line 1 for PT or SLT 2 by Parallel or eXtra Device Port connection of a PT and an SLT 3 by Digital eXtra Device Port connection of two DPTs and an SLT Ring Voltage 75 Vrms at 20 Hz 25 Hz depending on the Ringing Load Central Office Loop Limit 1600 Q maximum Hookswitch Flash Timing Range 24 ms to 2032 ms Door Opener Current Limit 24 V DC 30 V AC 1 A maximum External Relay Current Limit 24 V DC 30 V AC 1 A maximum External Sensor Current Limit Power to the external sensor is provided from the DPH4 card and must be grounded through the DPH4 card For the connection diagram refer to 2 5 1 DPH4 Card The Hybrid IP PBX detects input from the sensor when the signal is under 100 Q Paging Terminal Impedance 600 Q MOH Terminal Impedance 10 000 Q Installation Manual 25 1 4 Specifications 1 4 3 System Capacity Maximum CO Line and VoIP Line 26 The Hybrid IP PBX supports the following number of CO lines and VoIP lines Line Type Maximum Number CO Line 12 VoIP Line 4 Maximum Terminal Equipment The following number of items of terminal equipment can be supported by the Hybrid IP PBX For how to count the total number of items of equipment to be connected refer to MEC Card Calculation
79. ng the screw included with the card instead of the extension bolt 44 Installation Manual 2 2 Installation of the Hybrid IP PBX Handling of the Cables Attach the strap included with the card to one of the connected cables 1 2 Bind all the connected cables together using the strap 3 Repeat the procedure for other cards Installation Manual 45 2 2 Installation of the Hybrid IP PBX 4 Attach the main strap included with the Hybrid IP PBX to any of the 5 rails depending on your preference Main Strap 46 Installation Manual 2 2 Installation of the Hybrid IP PBX 5 Bind all the connected cables together using the main strap and then close the cable cover For how to close the cable cover refer to 2 2 3 Opening Closing the Covers Cable Cover Notes e For safety reasons do not stretch bend or pinch the cables e Ifyou prefer you can cut the other side of the cable cover and run the cables through that opening For safety reasons smooth the cut edges Installation Manual 47 2 2 Installation of the Hybrid IP PBX Removing the Optional Service Cards 1 Loosen the extension bolt CAUTION When removing the optional service cards do not put pressure on any parts of the main board e g tall capacitors Doing so may result in damage to the Hybrid IP PBX 48 Installation Manual 2 2 7 Types of Connectors 2 2 Inst
80. nnecting the CS to the Hybrid IP PBX 1 Keep pressing POWER button on the PS until the PS is turned OFF 2 Disconnect the AC adaptor or battery box from the CS and stop supplying electricity 3 Switch all DIP switches on the CS from ON to OFF OFF ON 100 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations 2 7 7 Connecting a Cell Station to the Hybrid IP PBX Refer to the following example to connect a CS to the Hybrid IP PBX Super Hybrid Port Cable Maximum Distance 26 AWG 222 m 728 ft 24 AWG 347 m 1138 ft 22 AWG 500 m 1640 ft 347 m 1138 ft A Super Hybrid Port or HLC4 DLC4 DLC8 card RJ11 Signal Name Signal Name D1 IS SESSI FEES 2 _3s_ Ooo S 8 E Accessories and User supplied Items for the CS Accessories included Screws x 2 Washers x 2 User supplied not included RJ11 connector Note For details about HLC4 card DLC4 card or DLC8 card refer to 2 4 1 HLC4 Card 2 4 2 DLC4 Card or 2 4 5 DLC8 Card Installation Manual 101 2 7 Connection of 2 4 GHz Portable Stations Connecting the CS 1 Connect the cable from a Super Hybrid Port or the HLC4 DLC4 DLC8 card to the CS Modular To a Super Hybrid Port or HLC4 DLC4 DLC8 card 2
81. ode can be selected through system programming If XDP mode is enabled through system programming parallel connection is not possible Refer to 1 10 9 Paralleled Telephone and 2 1 1 Extension Port Configuration in the Feature Guide for further information Using a Modular T Adaptor To a Super Hybrid Port Modular amp T Adaptor 44 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins D1 and gt D2 DPT SLT 82 Installation Manual 2 6 Connection of Extensions Using an EXtra Device Port With KX T7600 Series DPT To a Super Hybrid Port SIOE 2 conductor wiring cord Connect pins T and R 4 conductor wiring cord Connect pins T R D1 and D2 DPT SLT To a Super Hybrid Port TOSLT lt With Other DPT except KX T7560 and KX T7565 To a Super Hybrid Port 2 conductor wiring cord 4 conductor wiring cord Connect pins T and R Connect pins T R 7 D1 and D2 Lo gt To SLT To a Super Hybrid Port lt Installation Manual 83 2 6 Connection of Extensions 2 6 3 Digital EXtra Device Port Digital XDP Connection A DPT can be connected to another DPT on the Digital XDP connection In addition if the DPT is connected to a Super Hybrid Port it can also have an SLT connected in Parallel mode or XDP mode Notes e Both DPTs must be KX T7600 series DPTs excluding KX T7640
82. of a gas leak to report the leak Installation Manual SAVE THESE INSTRUCTIONS Installation Manual 5 Precaution WARNING DO NOT REMOVE SD MEMORY CARD WHILE POWER IS SUPPLIED TO THE HYBRID IP PBX Doing so may cause the Hybrid IP PBX to fail to start when you restart the system 6 Installation Manual e Keep the unit away from heating appliances and devices that generate electrical noise such as fluorescent lamps motors and televisions These noise sources can interfere with the performance of the Hybrid IP PBX e This unit should be kept free of dust moisture high temperature more than 40 C 104 F and vibration and should not be exposed to direct sunlight e Ifyou are having problems making calls to outside destinations follow this procedure to test the CO lines 1 Disconnectthe Hybrid IP PBX from all CO lines 2 Connect known working SLTs to those CO lines 3 Make a call to an external destination using those SLTs If a call cannot be carried out correctly there may be a problem with the CO line that the SLT is connected to Contact your telephone company If all SLTs operate properly there may be a problem with your Hybrid IP PBX Do not reconnect the Hybrid IP PBX to the CO lines until it has been serviced by an authorized Panasonic Factory Servicenter e Wipe the unit with a soft cloth Do not clean with abrasive powders or with chemical agents such as benzene or thinner WARNING e THIS UNI
83. on Proprietary Equipment KX A236 Additional AC Adaptor KX T30865 Doorphone Available Proprietary Telephones The Hybrid IP PBX supports Panasonic KX T7000 and KX TD7000 series telephones Note The Hybrid IP PBX does not support the following telephones KX T30800 series Proprietary Telephones and DSS consoles KX T61600 series Proprietary Telephones and DSS consoles KX T123200 series Proprietary Telephones and DSS consoles 2 Installation Manual Digital Analog proprietary telephones e g KX T7625 KX T7630 KX T7633 KX T7636 Portable stations e g KX TD7690 DSS consoles e g KX T7640 For the equipment e g Add on Key Module USB Module Headset that can be connected to a particular telephone refer to the telephone s manual For other equipment that can be connected to the Hybrid IP PBX refer to 1 2 2 System Connection Diagram Abbreviations in this manual Proprietary telephone PT Digital proprietary telephone DPT Analog proprietary telephone APT Portable station PS Single line telephone SLT 1 The KX T7090 headset can be connected to the KX T7000 KX T7200 KX T7300 and KX T7400 series telephones Installation Manual Important Safety Instructions 4 SAFETY REQUIREMENTS When using your telephone equipment basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 2 3 10 11 12 13
84. on a product identifier in the format US ACUMFO3AKX TDASO If requested this number must be provided to the telephone company Installation must be performed by a qualified professional installer If required provide the telephone company with the following technical information e Telephone numbers to which the system will be connected e Make Panasonic e Model KX TDA50 e Certification No found on the side of the unit e Ringer Equivalence No 0 3A e Facility Interface Code 02LS2 e Service Order Code 9 0F e Required Network Interface Jack RJ11 Ringer Equivalence Number REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local telephone company The REN for this product is part of the product identifier that has the format US ACJMFO3AKX TDASO The digits represented by 03 are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label Incidence of Harm to the Telephone Lines If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be requ
85. oor openers external relays To doorphones Accessories and User supplied Items Accessories included Extension Bolt x 1 Strap x 1 8 pin terminal block x 1 10 pin terminal block x 1 Telephone Line Cord x 2 Terminal Box x 2 User supplied not included Copper wire Note For details about connection to doorphones door openers external sensors and external relays refer to 2 8 1 Connection of Doorphones Door Openers External Sensors and External Relays Pin Assignments RJ11 Connector Signal Name Function DP2 Doorphone 2 transmit 1 i i 8 DP1 Doorphone 1 transmit ji mans com1 Doorphone 1 receive DP2 DP4 DEI DES com2 Doorphone 2 receive comi com3 com2 com4 z DP4 Doorphone 4 transmit DP3 Doorphone 3 transmit com3 Doorphone 3 receive com4 Doorphone 4 receive 70 Installation Manual 8 pin Terminal Block 2 5 Installation of the Other Cards Signal Name Function SENS ia SENS 1a Sensor Input 1 SENS 1b SENS 2a SENS 1b com 1 SENS 2b SENS 3 BENE Gb SENS 2a Sensor Input 2 AE SENS 2b com 2 1 foot 8 SENS 3a Sensor Input 3 SENS 3b com 3 SENS 4a Sensor Input 4 SENS 4b com 4 10 pin Terminal Block Signal Name Function OP 1b RL1b OP 1b RL1b Door opener 1 Relay 1 OP 1a RL1a ORSO Fi 2b OP1a RL1a Door op
86. other terminal is not obtained the outlet is not properly grounded This condition should be corrected by a qualified electrician per article 250 of the National Electrical Code If a reading of 0 volt at one terminal and a reading of 108 V AC to 132 V AC at the other terminal is obtained then set the meter to the OHMS RX1 scale place one probe at the GND Terminal and the other probe at the terminal which gave a reading of 0 volt A reading of less than 1 ohm should be obtained If the reading is not obtained the outlet is not adequately grounded See qualified electrician Installation Manual 2 2 Installation of the Hybrid IP PBX 2 2 6 Installing Removing the Optional Service Cards Slot Position tL 4 Jey L o9 JU os JEL oe Dl Oo esa 9 I 1 Slots 10 and 11 accept only cards that do not have external ports Therefore these slots do not have removable cover plates 2 Slot 02 has an LCOT4 card pre installed 3 Slot 01 contains the pre installed Super Hybrid Ports No optional service card can be installed Slot Restrictions The following table shows the slot restrictions W indicates that the slot supports the optional service card Card Slot Number Type Max 02 03 04 05 06 07 08 09 10 11 LCOT4 3 Viviv HLC4 Vv Y Y DLC4 Vv Vv Vv SLC4 Ylvi Y PLC4 Y Y Y IP GW4 1 Y Vv Vv DLC8 Vv
87. overage areas of at least 2 CSs at any location in the installation site c Make sure that the radio signal strength level is greater than 3 at any location in the service area demanded by the user Referring to the Stored Scan Data Using the KX TD7680 Display example DD S gt P Scan Data No gt pren there is scan data 0 1 CS No 2 LEVEL 9 Press 1 9 and POWER Oto9 for more than 2 seconds When there is no scan data NOT SAVED z e o To the Desired Scan Data No Using the KX TD7690 Display example A gt P Scan Data No gt When there is scan data CS No 2 LEVEL 9 Press 1 9 and POWER Oto9 for more than 2 seconds z e H When there is no scan data NOT SAVED z e o To the Desired Scan Data No 98 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations Deleting the Stored Scan Data Using the KX TD7680 O QD gt ScanDatano gt O gt Press 1 9 and POWER 0 to 9 or for all data for more than 2 seconds To the Desired Scan Data No Using the KX TD7690 Od gt ScanDataNo gt gt Press 1 9 and POWER 0 to 9 or for all data for more than 2 seconds To the Desired Scan Data No Installation Manual 99 2 7 Connection of 2 4 GHz Portable Stations 2 7 6 After Site Survey After obtaining the proper measurement results exit the Radio Signal Test mode before co
88. ow Main Board MPR malfunction 013 Additional AC Additional AC power down e Check the power supply system power down Bad connection or breaking of e See if the additional AC cord is additional AC cord connected properly e Check the additional AC cord e Replace the additional AC cord be sure to turn off the Hybrid IP PBX when replacing 019 Additional AC Additional AC power on e Check the power supply system power on Bad connection or breaking of e See if the additional AC cord is connected properly Check the additional AC cord Replace the additional AC cord be sure to turn off the Hybrid IP PBX when replacing 144 Installation Manual 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 020 SD file access e SD Memory Card malfunction e Press the Reset Button error e Bad connection of SD e Reprogramthe Hybrid IP PBX Memory Card e Replace the SD Memory Card e Main Board malfunction e Replace the Hybrid IP PBX 021 SD Memory Card SD Memory Card not disconnected installed e Bad connection of SD Memory Card e SD Memory Card malfunction e Main Board malfunction 022 Not enough free e Not enough memory space e Delete the files whose file names start space on SD card available to save the system with from SD Memory Card data or to upload system files from the KX TDA50 Note Maintenance Console Do not delete the PSMPR file it is the program file of the Main
89. ow in the white cells 00 01 02 03 04 05 06 07 08 09 0a Ob Oc Od Oe oF e 11 oM so o 1 2 3 I4 zello JL IL lt IL 1 12 40 e A8 c Dl e u iy lik Lim so P_ oR S T wx yzi 60 EN a o o la Lg nli i ikli im Ln Lo zo e llall rI sI t wix ly z 4 ao lt e GN BESNESNSN o A ATATA LA c e eee i i i i ole RA ol te t6 6 iae o e 0 0 Malena gA SN O 5 72MM Ga yy MD e The PC will not perform any shutdown operation or enter the power saving system standby mode while the KX TDA50 Maintenance Console is connected to the Hybrid IP PBX To perform either of the operations above first close the connection to the Hybrid IP PBX 3 fe felre BERR lt 1 a leo Mal a lalala o o gt x Eo 130 Installation Manual 3 3 Installation of the Hybrid IP PBX PC Programming Software CAUTION Do not remove the SD Memory Card while power is supplied to the Hybrid IP PBX Doing so may cause the Hybrid IP PBX to fail to start when you try to restart the system Installation Manual 131 3 3 Installation of the Hybrid IP PBX PC Programming Software 132 Installation Manual Section 4 Troubleshooting This section provides information on the Hybrid IP PBX and telephone troubleshooting Installation Manual 133 4 1 Troubleshooting 4 1 Troubleshoot
90. ped on or tripped on To reduce the risk of fire or electric shock do not overload wall outlets and extension cords Do not insert objects of any kind into this product through its slots and openings as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock Never spill liquid of any kind on or in the product To reduce the risk of electric shock do not disassemble this product Only qualified personnel should service this product Opening or removing covers may expose you to dangerous voltages or other risks Incorrect reassembly can cause electric shock Unplug this product from the wall outlet and have it serviced by qualified service personnel in the following cases a When the power supply cord or plug is damaged or frayed b If liquid has been spilled into the product c If the product has been exposed to rain or water d Ifthe product does not operate according to the operating instructions Adjust only the controls that are explained in the operating instructions Improper adjustment of other controls may result in damage and may require service by a qualified technician to restore the product to normal operation e If the product has been dropped or the cabinet has been damaged f If product performance deteriorates Avoid using wired telephones during an electrical storm There is a remote risk of electric shock from lightning Do not use a telephone in the vicinity
91. ptor can also be connected Panasonic E Construction of Main Unit LCOT4 card installed by default A Front Cover Main Board Cable Cover 18 Installation Manual 1 2 Basic System Construction 1 2 2 System Connection Diagram CO Telephone Company Lines ____ Analog Remote PC Hybrid IP o Fax Machine ig Wireless Phone External Sensor External Relay Device E Doorphone amp Door Opener BGM Music On Hold MOH Pager Amplifier Speaker Voice Processing System gn QU Private IP Network O Router PBX seoor 00000000 CTI Server I PC PC APT DSS Console DPT DSS Console KX T7636 KX T7633 AA KX T7600 DPT KX T7600 DPT Installation Manual 19 1 2 Basic System Construction Hybrid IP PBX ___ KX T7636 KX T7633 PC DSS Console LCOTA4 DLC8 KX TDA5180 KX TDA5172 Telephone Analog I d Company CO Line CID4 DLC4 H Voice KX TDA5193 fm KX TDA5171 Je PT interface CS PS System IP GW4 ARI EE Voice Processing Private Router HLC4 AP DSS Console System IP Network KX TDA5170 oi SLC8 Wireless Phone Fax Machine PT interface CS PS KX TDA5174 SLC4 5 5 3 KX TDA5173 T f o Kx TDASITO Wireless Phone Fax Machine PLC4 J b
92. r DISABLE igits 4 digits X gt 2 C Tone 104 Installation Manual 2 7 Connection of 2 4 GHz Portable Stations Using the KX TD7690 QS D gS BD Select SI SI Choose _ SYSTEM LOCK Enable Disable GEL System Lock Password gt gt System Lock Password gt gt S Bice S1 DISABLE 4 digits 4 digits lt q gt gt J C Tone S1 Setting the Personal Identification Number PIN for PS Registration To prevent registering the PS to a wrong Hybrid IP PBX a PIN for PS registration can be set to the Hybrid IP PBX Before registering the PS to the Hybrid IP PBX register the PIN set to the Hybrid IP PBX into the PS By doing so the PS will only be registered to the Hybrid IP PBX with the matching PIN Notes e By default the PIN for PS registration is 1234 for both the Hybrid IP PBX and PS Therefore the PS can be registered to the Hybrid IP PBX without setting the PIN e The PIN for PS registration will only be used when registering the PS to the Hybrid IP PBX Therefore even when there is more than 1 Hybrid IP PBX with the same PIN near the PS the PS will not be linked to a different Hybrid IP PBX during normal operation after registration Setting the PIN for Hybrid IP PBX 692 gt PINfor PS Registration gt gt 1 to 4 a 123 ENTER ENTER Setting the PIN for PS Using the KX TD7680 D gt PINforPSRegistration gt d T Select 1 to 4 digits SAR
93. raged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Some wireless telephones operate at frequencies that may cause interference to nearby TVs and VCRs To minimize or prevent such interference the base of the wireless telephone should not be placed near or on top of a TV or VCR If interference is experienced move the wireless telephone further away from the TV or VCR This will often reduce or eliminate interference Operating near 2 4 GHz electrical appliances may cause interference Move away from the electrical appliances CAUTION To comply with FCC RF exposure requirements in uncontrolled environment e This equipment must be installed and operated in accordance with provided instructions and a minimum 20 cm 8 in spacing must be provided between antenna and all person s body excluding extremities of hands wrist and feet during wireless modes of operation e This transmitter must not be co located or operated in conjunction with any other antenna or transmitter Medical consult the manufacturer of any personal medical devices such as pacemakers to determine if they are adequately shielded from external RF r
94. rid IP PBX set the A A1 Hybrid IP PBX Extension relay switch of the telephone to OFF Yes Connection between the Hybrid IP PBX and an SLT that is polarity sensitive CAUSE SOLUTION The T is connected to the R Reverse the connections of the T R D10 T T Re te R D2 J Hybrid IP PBX Extension Continued on the next page 136 Installation Manual 4 1 Troubleshooting Continued from the previous page Connection between the central office and the Hybrid IP PBX CAUSE SOLUTION CO line is connected to the T2 T1 T2 e eR e e Ti Can you dial No R2 outona gt CO line CO line Hybrid IP PBX CO line is connected to the T2 R1 CO line T2 R1 Ti R2 Hybrid IP PBX Reconnect the CO line to the T1 R1 or T2 R2 of the telephone jack using 2 conductor wiring Installation Manual 137 4 1 Troubleshooting 4 1 3 Operation PROBLEM PROBABLE CAUSE SOLUTION When using the speakerphone on an APT nothing is audible When using the speakerphone monitor mode with a DPT nothing is audible The HANDSET HEADSET selector is set to the HEADSET position The HEADSET mode is selected by Personal Programming Handset Headset Selection When the headset is not used set the HANDSET HEADSET selector to the HANDSET
95. rogramming reference for the Hybrid IP PBX To program and administer the Hybrid IP PBX by PC you need to install the KX TDA50 Maintenance Console onto the PC This manual describes overview and installation of the KX TDA50 Maintenance Console only KX TDA50 Maintenance Console Menu Bar GSO amp E 4 Extension 5 Optional Device 9 Private Network E 10 C0 amp Incoming Call 11 Maintenance Program Menu 1 The contents and design of the software are subject to change without notice 124 Installation Manual 3 2 Connection 3 2 Connection 3 2 1 Connection Serial Interface Connection f RS 232C Port To COM Port gt U sii To USB Port gt PC USB Port For pin assignments and maximum cabling distance refer to 2 9 1 Connection of Peripherals Installation Manual 125 3 2 Connection External Modem Connection i RS 232C Port DODO To CO line Hybrid IP PBX extension port assigned as the CO line destination Hybrid IP PBX External Modem Signal Name Pin No Pin No Signal Name D RXD 2 2 SD TXD SD TXD 3 sr a 3 RD RXD R DTR 4 6 DR DSR DR DSR 6 un 20 ER DTR After connecting the Hybrid IP PBX and the external modem set the power switc
96. s connected only to DC IN 2 the Hybrid IP PBX will not start If you need to connect an additional AC adaptor plug the DC connector of the additional AC adaptor into DC IN 2 DC Connector gt DC IN 2 Xx Additional AC Adaptor AC Adaptor Installation Manual 119 2 11 Starting the Hybrid IP PBX 3 Plug the AC cord into the AC adaptor and then plug the other end into an AC outlet AC Adaptor I to AC Cord To AC outlet a 4 Turnon the power switch The RUN indicator will flash Power Switch Notes e For safety reasons follow the procedures as indicated when turning on the Hybrid IP PBX e For safety reasons do not stretch bend or pinch the AC cord and the DC cable of the AC adaptor 5 While the RUN indicator is flashing return the System Initialize Switch to the NORMAL position Depending on the configuration initialization takes about 1 min to 3 min If successfully executed the RUN indicator will stop flashing and be kept lit All data will be cleared and the Hybrid IP PBX as well as all optional service cards except for the IP GW4 card will be initialized to the default values The DPTs should show the time as 01 00 The data of the IP GW4 card will not be initialized Note Use the same types of AC adaptor and AC cord that are supplied with the Hybrid IP PBX only 120 Installation Manual 2 11 Starting the
97. s information is logged when IP GW remote maintenance PC is stopped from remote maintenance PC Installation Manual 147 4 1 Troubleshooting Error Code Error Message PROBABLE CAUSE SOLUTION 370 IP GW Rebooted e IP GW is rebooted from a e This information is logged when IP GW by Maintenance remote maintenance PC is rebooted from a remote Console maintenance PC 371 IP GW Rebooted e Optional service card e Check whether the software version of malfunction IP GW the IP GW card is correct e Replace the corresponding optional service card 372 NDSS message Optional service card e Ignore if not frequent over IPGW malfunction IP GW e Change the IP GW card status to Out notification of Service and then back to In Service caused by IPGW Tx resource limitation 373 NDSS message over IPGW notification caused by IPGW Rx resource limitation 374 NDSS message over IPGW notification caused by shortage of IPGW resource 375 NDSS message Network malfunction e Ignore if not frequent over IPGW e Consult your network administrator notification caused by Network side 391 Data Link e Connection with PC Phone e This information is logged when established PC Console or Voice connection with PC Phone PC Processing System DPT Console or Voice Processing System Integration established or DPT Integration is established and restored does not indicate an error con
98. s page and use as a reference for wall mounting Install a screw here 110 mm 4 5 16 in Install a screw here Note Make sure to set the print size to correspond with the size of this page If the dimension of the paper output still deviates slightly from the measurement indicated here use the measurement indicated here Installation Manual 55 2 2 Installation of the Hybrid IP PBX 2 2 10 Surge Protector Installation 56 Overview A massive electrical surge can be caused if lightning strikes a telephone cable 10 m 33 ft above ground or if a telephone line comes into contact with a power line A surge protector is a device that is connected to a CO line to prevent potentially dangerous electrical surges from entering the building via the CO line and damaging the Hybrid IP PBX and connected equipment To protect the system from electrical surges we strongly recommend connecting the system to a surge protector that meets the following specifications e Surge arrestor type 3 electrode arrestor e DC spark over voltage 230 V e Maximum peak current at least 10 kA Additionally proper grounding is very important for the protection of the system refer to 2 2 5 Frame Ground Connection Many countries areas have regulations requiring surge protection Be sure to comply with all applicable laws regulations and guidelines Installation CO Line CO Line CO Line S
99. stallation Precautions 30 Installing and Starting the KX TDA50 Maintenance Console 127 Installing the KX TDA50 Maintenance Console 128 Installing Removing the Optional Service Cards 39 IP GW4 Card 61 K KX A236 Additional AC Adaptor 22 KX TDA5105 Memory Expansion Card 21 76 KX TDA5161 4 Port Doorphone Card 21 70 KX TDA5166 8 Channel Echo Canceller Card 21 73 KX TDA5168 Extension Caller ID Card 21 75 KX TDA5170 4 Port Hybrid Extension Card 21 63 KX TDA5171 4 Port Digital Extension Card 21 64 KX TDA5172 8 Port Digital Extension Card 21 67 KX TDA5173 4 Port Single Line Telephone Extension Card KX TDA5174 8 Port Single Line Telephone Extension Card KX TDA5175 4 Port Proprietary Extension Card 21 66 KX TDA5176 8 Port Proprietary Extension Card 21 69 KX TDA5180 4 Port Analog Trunk Card 21 59 KX TDA5191 2 Channel Message Card 21 74 KX TDA5193 4 Port Caller ID Card 21 60 KX TDA5196 Remote Card 22 78 KX TDA5480 4 Channel VoIP Gateway Card 22 61 KX TDA5920 SD Memory Card for Software Upgrade to Enhanced Version 22 37 21 65 21 68 nnan Index L LCOT4 Card 59 M Main Unit 18 Maximum Cabling Distances of the Extension Wiring Twisted Cable 80 Maximum CO Line and VoIP Line 26 Maximum Terminal Equipment 26 MEC Card 76 MEC Card Calculation 27 Memory Expansion Card KX TDA5105 MPR Version 1 1 152 MPR Version 2 0 153 MSG2 Card 74 N Names and Locations 33 Networking Features 16 21
100. t the same distance from the wall e Install the screws perpendicular to the wall 3 Hook the CS on the screw heads Installation Manual 107 2 7 Connection of 2 4 GHz Portable Stations Reference for Wall Mounting Please copy this page and use as a reference for wall mounting Install a screw here 71mm 2 13 16 in Install a screw here Note Make sure to set the print size to correspond with the size of this page If the dimension of the paper output still deviates slightly from the measurement indicated here use the measurement indicated here 108 Installation Manual 2 8 Connection of Doorphones Door Openers External Sensors and External Relays 2 8 Connection of Doorphones Door Openers External Sensors and External Relays 2 8 1 Connection of Doorphones Door Openers External Sensors and External Relays A maximum of 4 doorphones KX T30865 4 door openers or external relays and 4 external sensors can be connected to the Hybrid IP PBX Note Doorphones door openers external sensors and external relays are user supplied Maximum Cabling Distance j Cable Maximum Distance Doorphone 26 AWG 70 m 230 ft 24 AWG 113 m 371 ft 22 AWG 180 m 590 ft CAT 5 113 m 371 ft Door Opener External Sensor External Relay Device Meio yet rece en Sen eee Ni eye er ee cae eres ane ee ae eer
101. that the front hooks fit in place Im l aif _ SS 36 Installation Manual 2 2 Installation of the Hybrid IP PBX 2 2 4 Installation of the SD Memory Card LED E S O SD Memory Card SD Memory Slot Cover Card w Nng i o E CAUTION e Useonly the SD Memory Card included with the Hybrid IP PBX or a Panasonic optional upgrade SD Memory Card e The SD Memory Card contains software for all the processes of the Hybrid IP PBX and all the customer data The SD Memory Card must be inserted before start up e Do not remove the SD Memory Card while power is supplied to the Hybrid IP PBX Doing so may cause the Hybrid IP PBX to fail to start when you try to restart the system Note If you need to remove the SD Memory Card LED Indications Indication Color Description SD ACCESS Green SD memory card status e ON Accessing Installation Manual 37 2 2 Installation of the Hybrid IP PBX 2 2 5 Frame Ground Connection IMPORTANT Connect the frame of the Hybrid IP PBX to ground 1 Loosen the screw 2 Insert a grounding wire user supplied 3 Tighten the screw 4 Connect the grounding wire to ground Grounding wir
102. the back of the cabinet will not be blocked e Be careful not to drop the cabinet 52 Installation Manual 2 2 Installation of the Hybrid IP PBX 2 2 9 Wall Mounting AC Adaptor Mounting on Wooden Wall 1 Place the reference for wall mounting on the following page on the wall to mark the two screw positions Install the screws and washers included in the wall Drive the La to this position Notes e Make sure that the screw heads are at the same distance from the wall e Install the screws perpendicular to the wall 3 Hook the AC adaptor on the screw heads Note Be careful not to drop the AC adaptor Installation Manual 53 2 2 Installation of the Hybrid IP PBX Mounting on Concrete or Mortar Wall CAUTION Drive mounting screws into the wall Be careful to avoid touching any metal laths wire laths or metal plates in the wall 1 Place the reference for wall mounting on the following page on the wall to mark the two screw positions 110 mm 4 5 16 in 2 Install two anchor plugs user supplied in the wall Hammer Anchor Plug gt 29 mm 1 1 8 in 6 4 mm 1 4 in 3 Install the screws included in the wall Drive the screw to this position 4 Hook the AC adaptor on the screw heads Note Be careful not to drop the AC adaptor 54 Installation Manual 2 2 Installation of the Hybrid IP PBX Reference for Wall Mounting Please copy thi
103. the same room as the above equipment Within 1 8 m 6 ft of radios and televisions Both the Hybrid IP PBX and PTs should be at least 1 8 m 6 ft away from such devices Locations where other objects will obstruct the area around the Hybrid IP PBX Be especially careful to leave at least 20 cm 8 in of space above and 10 cm 4 in to the sides of the Hybrid IP PBX for ventilation Do not stack up the optional service cards To avoid damage to the optional service cards always use the extension bolts Wiring Precautions Be sure to follow these instructions when wiring the unit 1 Do not run unshielded telephone cables near AC power cables computer cables AC power sources etc When running cables near other noise generating devices or cables use shielded telephone cables or shield the telephone cables with metal tubing If cables are run on the floor use protectors to prevent the cables from being stepped on Avoid running cables under carpets Avoid using the same AC outlet for computers telexes and other office equipment as noise generated by such equipment may hamper system performance or interrupt the system Installation Manual 11 2 1 Before Installation Use 2 pair telephone cables when connecting PTs Use 1 pair telephone cables when connecting SLTs data terminals answering machines computers Voice Processing Systems etc Unplug the system from its power source when wiring and plug the system back in
104. tions 2 2 Procedure Overview When connecting the wireless system use extreme care to conduct a site survey Inadvertent site survey can result in poor service area frequent noise and disconnection of calls 1 Investigate the installation site Refer to 2 7 3 Site Planning a Obtain the map of the CS installation site b Consider the service area demanded by the user on the map c Plan the locations of each CS taking account of distance building materials and etc 2 Prepare the CS for site survey Refer to 2 7 4 Before Site Survey a Assign a CS number to each CS by setting the DIP switches on the back of the CS b Supply electricity to each CS using an AC adaptor or a battery box c Install each CS temporarily as planned Notes e Install at least 2 m 6 ft 7 in above the floor e Keep the antennas in the upright position 3 Conduct the site survey Refer to 2 7 5 Site Survey a Test the radio signal strength using the PS Confirm that the radio signal strength level is 12 near the CS Using the KX TD7680 Display example see I Press 1 9 and POWER 1t09 A for more than 2 seconds Using the KX TD7690 Display example 220 gt E Press 1 9 and POWER 1t09 dn for more than 2 seconds b By walking away from the CS with the PS check the radio signal strength The radio signal strength weakens as you walk away from the CS c Map the CS coverage area at radio signal strength levels
105. to place Then holding the card firmly in place lower the rear end so that the hole of the card fits over the extension bolt Extension Bolt CAUTION When installing the optional service cards do not put pressure on any parts of the main board e g tall capacitors Doing so may result in damage to the Hybrid IP PBX 3 Insert the new extension bolt included with the card into the hole on the card and tighten it to secure the card Installation Manual 41 2 2 Installation of the Hybrid IP PBX 4 Stick an appropriate optional card label included to the left side of the corresponding card a Optional Card Label 5 Connect a cable to an appropriate port of the card For details about pin assignments refer to the appropriate section in 2 3 Installation of the CO Line Cards and 2 4 Installation of the Extension Cards Note Make sure to connect cables after installing the card in the Hybrid IP PBX not before 42 Installation Manual 2 2 Installation of the Hybrid IP PBX 6 Repeat the procedure for other cards A When installing a card in Slot 07 make sure to detach the LED holder first After installing the card reattach the LED holder To detach the LED holder 2 o kej A LU sa To attach the LED holder Installation Manual 43 2 2 Installation of the Hybrid IP PBX B When installing a card in Slot 11 tighten the card usi
106. urge Protector Terminal Board Exin Hybrid IP PBX Extn Extn Extn ia de ee F SLT PT CS dini Ground Extn Extension line Installation Manual 2 2 Installation of the Hybrid IP PBX Outside Installation Main Building Surge Protector CO Line CO Line Another Building A SLT PT Terminal Hybrid Extn IP PBX CS Board Ein Sura 08 Protector Extn Extn x n SLT PT CS Ground Extn Extension Line If you install an extension outside of the building the following precautions are recommended a Install the extension wire underground b Use a conduit to protect the wire Note The surge protector for an extension and CS is different from that for a CO line Installation of a Ground Rod Surge Protector CO Line N Hybrid ire IP PBX Underground Ground Rod Installation Manual 57 2 2 Installation of the Hybrid IP PBX Connect the ground rod to the surge protector using a grounding wire with a cross sectional area of at least 1 3 mm2 2 Bury the ground rod near the protector The grounding wire should be as short as possible 3 The grounding wire should run straight to the ground rod Do not run the wire around other objects 4 Bury the ground rod at least 50 cm 20 in underground N e The above figures are recommendations only e The length o
107. uthorized access and possible abuse of the PBX keep the passwords secret and inform the customer of the importance of the passwords and the possible dangers if they become known to others 3 The PBX has default passwords preset For security change these passwords the first time that you program the PBX 4 Change the passwords periodically 5 Itis strongly recommended that passwords of 10 numbers or characters be used for maximum protection against unauthorized access For a list of numbers and characters that can be used in system passwords refer to 3 1 3 Entering Characters in the Feature Guide 6 Ifa system password is forgotten it can be found by loading a backup of the system data into a PC and checking the password using the KX TDA50 Maintenance Console software If you do not have a backup of the system data you must reset the PBX to its factory defaults and reprogram it Therefore we strongly recommend maintaining a backup of the system data For more information on how to back up the system data refer to the on line help of the Maintenance Console However as system passwords can be extracted from backup copies of the system data file do not allow unauthorized access to these files Installation Manual 127 3 3 Installation of the Hybrid IP PBX PC Programming Software Installing the KX TDA50 Maintenance Console Notes E Make sure to install and use the KX TDA50 Maintenance Console for MPR version 2 0
108. y Card ii 37 22 5 Frame Ground Connection illa 38 2 2 6 Installing Removing the Optional Service Cards 0 ecccecceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeteneeeeeeea 39 2 27 WOES Ol COMMECIONS inni Rigi 49 2 2 8 Wall Mounting KA T DAS sisecicvcticercuwuasneencesdmendendieaseenadnecaaunniten a xeundebt aaa 50 2 2 9 Wall Mounting AC Adaptor ascii lager 53 2 2 10 Surge Protector Installation farro 56 2 3 Installation of the CO Lime Cards ssssssssserssssssessesssersssesenssneseceessensnsecensorseseessnesnonoes 59 dal OA 59 2 32 CID4 Caid irie rara aaa 60 23 3 odia 61 2 4 Installation of the Extension Cards ceseeeseeeeesseeeeeeeeeneeeeeeeeeeeeeseeeseeeseeeseneneees 63 a e E EIA 63 242 DIA anali 64 248 PALI Lierac 65 244 PLUG araldica 66 24 5 DIR Clicca ian 67 246 Edili 68 247 PBI lla 69 2 5 Installation of the Other Card cccccssseeeeeeeeesseessneeeeeeeeeeesnneneeeeeeeenenseeeeneeeeeeeeeeeesenoes 70 251 PPHECadisclollo lella 70 252 EH ciccia 73 Oa po RM Melilli a 74 254 EXFCID aaa 75 25 5 MEC Cardesse ac tee Gorman aae EAEE EEEE EEE ha encores iii 76 256 RMT Card lara 78 2 6 Connection of Extensions Ie 80 Installation Manual 13 14 2 6 1 Maximum Cabling Distances of the Extension Wiring Twisted Cable 80 2 6 2 Parallel Connection of the Extensions ii 82 2 6 3 Digital EXtra Device Port Digital XDP Connection

Download Pdf Manuals