Home
Oregon Scientific BAR608HGA Radar Detector User Manual
Contents
1. e Orecon SCIENT FIC Wireless Weather Station Model BAR608HGA User Manual BAR608HGA lab test cover R2 1 1 8 04 6 38 PM CONTENTS Silence Alarm Barometer gc ee 1 Barometric Trend eene Set Unit and Altitude Weather Forecast Introduction About Oregon Scientific Product Overview Front VEW 3 Back View Remote Sensor THGR122NX Getting Started oou 6 Temperature and Humidity Select Temperature Unit 11 Select Channel Number Minimum Maximum Records Moon Phase Batteries m Access Front Button Panel Backlight RE Change Settings Reset System Table Stand or Wall Mount nn 6 Safety and Care 12 Remote Sensor THGR122NX Warnings Setup Sensor Troubleshoolifigi sic timet armenmeecen 12 Data Transmission 8 Specifications Search for Sensor 8 Main Unit Dimensions Clock 8 Remote Sensor Dimensions 13 Turn Atomic Clock ON OFF Temperature eret ehe e ee eene Set Clock T 9 Relative Humidity Switch Clock Display Barometer Alarms Remote Sensor THGR122NX View Alarm Settings sess 9 Le inem A AE EEES Set Alarm Activate Alarm BAR608HGA lab test R2 1 1 17 04 4 39 PM cesT Thank y
2. take more accurate barometric measurements BAROMETER 1 Press PRESSURE to select the unit of measurement mb hPa or inHg Press and hold PRESSURE for 2 seconds This product tracks barometric pressure changes over the past 24 hours to provide the weather forecast 13 and a trend line showing the direction of 3 Select the altitude 328 feet to 8203 feet in barometric change Barometric changes are measured increments of approximately 33 Press UP or by the main indoor unit DOWN to change the setting Press PRESSURE to confirm WEATHER FORECAST Trend Description This product forecasts the next 12 to 24 hours of weather W Risin within a 30 to 50 km 19 31 mile radius with 70 to 9 75 percent accuracy The weather forecast is always displayed Steady Clear Partly Cloudy Cloudy Rainy Falling S PKT hf 10 BAR608HGA lab test R2 10 1 17 04 4 39 PM HEN BAR608HGA lab test R2 11 This product can display current minimum and maximum temperatures and humidity percentage information collected by the remote sensors and main indoor unit Outdoor data is collected and displayed every 40 seconds Indoor data is collected and displayed every 10 seconds Slide the C F switch into the desired location The Switch is located on the front button panel The setting for the main unit overrides the remote sensor setting Press CHANNEL to switch
3. x UM 3 AA 1 5V alkaline 2xUMH AAA 1 5V alkaline 1 17 04 4 40 PM OO This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Ka FCC STATEMENT BAR608HGA lab test R2 15 LI Reorient or relocate the receiving antenna Increase the separation between the eq
4. between sensors 1 3 The icon shows the selected sensor Kinetic wave Icon Remote Display Remote Display Remote Display To auto scan between sensors press and hold CHANNEL for 2 seconds Each sensor s data will be displayed for 3 seconds To end auto scan press CHANNEL or MEM TEMPERATURE AND HUMIDITY S NOTE f you use a sensor that collects only temperature data humidity will not be shown Press MEM to toggle between current maximum MAX and minimum MIN records To clear the records press and hold MEM for 2 seconds A beep will sound to confirm that the memory has been cleared MOON PHASE The Calendar must be set for this feature to work 9 Press A or V to view the moon phase for the next or previous day Press and hold A or W to scan quickly through the years 2001 to 2099 BACKLIGHT Press SNOOZE LIGHT to activate the backlight for 8 seconds RESET SYSTEM The RESET button is located behind the front button panel for the main unit Press RESET when you change the batteries and whenever performance is not behaving as expected for example unable to establish radio frequency link with remote sensor or Atomic clock 1 17 04 4 40 PM EN ga EN NOTE When you press RESET all settings will return to default value and you will lose all stored information SAFETY AND CARE Clean the product with a slightly damp cloth and alcohol free mild detergent Avo
5. failure This is normal and does not affect general product performance The reception will resume once the interference ends BAR608HGA lab test R2 8 P m ej oles This product shows the current time and day of week in English French German Italian or Spanish The US Atomic Clock in Boulder Colorado automatically updates this information unless you disable the feature The signals are collected by the main unit when it is within 1500 km 932 miles of a signal Initial reception takes 2 10 minutes and is initiated when you first setup the unit and whenever you press RESET Once complete the reception icon will stop blinking The icon is shown in the Clock Area Strong signal Weak signal Nosignal Pitta i l To force a manual search for Atomic Clock signals press and hold UP for 2 seconds If no signal is found check the batteries NOTE If the Atomic Clock signal is received and the hour is incorrect use the timezone offset feature to adjust it to the appropriate timezone Please see SET CLOCK on pg 9 for instructions 1 17 04 4 39 PM ee BAR608HGA lab test R2 9 Perform this step if you cannot receive Atomic Clock signals Press and hold DOWN for 2 seconds Then manually set the clock following the Set Clock instructions below SN The signal icon indicates that the Atomic Clock L feature is ON No icon means that it is OFF You only need to do this if you have disabled the Atom
6. ic Clock feature for example if you are too far from or cannot receive a signal 1 Press and hold MODE for 2 seconds The Clock Area will blink 2 Select the time zone hour minute year month day and language Press UP or DOWN to change the setting Press MODE to confirm NOTE The language options are E English F French D German I Italian and S Spanish NOTE The time zone options are PA Pacific CE Central MO Mountain and EA Eastern Press MODE to toggle between Clock with Seconds and Clock with Weekday display ALARMS This product is equipped with a 2 minute crescendo alarm Press The Alarm Time and status will show in the Clock Area Press to switch to Alarm display 2 Press and hold again for 2 seconds The Alarm settings will blink 3 Select the hour and minute Press UP or DOWN to change settings Press to confirm Press to activate or deactivate the Alarm P shows in the Clock Alarm Area when the Alarm is activated When the Alarm time is reached the crescendo alarm will sound for 2 minutes Press SNOOZE LIGHT to silence it for 8 minutes Or press to turn it off until the next day 1 17 04 4 39 PM zZ 5 If no button is pressed the Alarm will automatically silence after 2 minutes It will then sound again after You can set the unit of measurement mb hPa or inHg 8 minutes and altitude Doing this allows the product to
7. id dropping the product or placing it in a high traffic location This product is designed to give you years of service if handled properly Observe the following guidelines Never immerse the product in water This can cause electrical shock and damage the product Do not subject the main unit to extreme force shock or fluctuations in temperature or humidity Do not tamper with the internal components Do not mix new and old batteries or batteries of different types Donotuserechargeable batteries with this product Remove the batteries if storing this product for a long period of time Do not scratch the LCD display BAR608HGA lab test R2 12 Do not make any changes or modifications to this product Unauthorized changes may void your right to use the product The technical specification of this product and contents of this user guide are subject to change without notice Images not drawn to scale TROUBLESHOOTING Check here before contacting our customer service department Problem Symptom Remedy Calendar Strange date Change language month gt 9 Clock Cannot adjust Disable Atomic Clock clock gt 9 Cannot auto 1 Adjust batteries synch gt 6 2 Press RESET gt 11 3 Manually activate Atomic Clock feature 9 Temp Shows LLL Temperature is out of or HHH range Remote Cannot locate Check batteries 6 sensor remote sensor Chec
8. k location 7 1 17 04 4 40 PM Problem Symptom Remedy Remote Cannot Check sensors Only sensor change one sensor is working channel 27 Data does Initiate a manual sensor not match search 8 main unit BAR608HGA lab test R2 SPECIFICATIONS LxWxH Weight LxWxH Weight Unit Indoor Range Outdoor Range Resolution 142 x 63 x 158 mm 5 5 x 2 5 x 6 2 inches 366 g 12 96 ounces with battery 92 x 60 x 20 mm 3 6 x 2 4 x 79 inches 63 grams 2 22 ounces without battery C or F 5 C to 50 C 23 F to 122 F 20 C to 60 C 4 F to 140 F 0 1 C 0 2 F 1 17 04 4 40 PM MTT Z UU Range Resolution Memory Unit Range Resolution Altitude Display RF frequency Range Transmission Channel No BAR608HGA lab test R2 25 to 95 1 Minimum maximum mb hPa or inHg 700 to 1050 mb 20 67 to 30 01 inHg 1 mb 0 03 inHg 328 to 8203 feet Rainy cloudy partly cloudy sunny 433 MHz 30 meters 98 feet with no obstructions every 40 seconds 1 3 Atomic Clock Clock display Hour format Time zone Calendar Alarm Main unit batteries Sensor batteries Auto or manual disabled HH MM SS 12hr AM PM PA Pacific MO Mountain CE Central or EA Eastern MM DD weekday in 5 languages E D F S Single alarm with 2 minute crescendo and 8 minute Snooze 3
9. ou for selecting the Oregon Scientific M Wireless Weather Station BAR608HGA This device bundles precise time keeping weather forecast barometric trend with altitude adjustment and indoor and outdoor temperature and humidity monitoring features into a single tool you can use from the convenience of your home In this box you will find Main unit Remote sensor THGR122NX Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know BAR608HGA lab test R2 2 z INTRODUCTION ABOUT OREGON SCIENTIFIC Visit our website www oregonscientific com to learn more about other Oregon Scientific products such as digital cameras hand held organizers health and fitness gear and projection clocks The website also includes contact information for our customer service department in case you need to reach us 1 17 04 4 39 PM PRODUCT OVERVIEW x L fo 39 dbi 4 es Cus 6 BAR608HGA lab test R2 PB OE Ol IN 11 12 13 14 15 SNOOZE LIGHT button Weather Forecast amp Barometric Trend Area Outdoor Temperature amp Humidity Area Indoor Temperature amp Humidity Area Clock Alarm Area Moon Phase A and Y increase or decrease setting activate or deactivate Atomic Clock RESET hole view alarm status set alarm MEMORY view current maximum and minimum tem
10. perature humidity readings CHANNEL switch remote sensor MODE change display settings C F switch P turn alarm off for 24 hours Altitude pressure change measurement unit mb hPa or inHg and value 1 17 04 4 39 PM Zz UU Zz UU BACK VIEW 1 Wall mount 2 Battery compartment 3 Table stand BAR608HGA lab test R2 4 1 17 04 4 39 PM cel 2 3 c 4 Daaa uma 15vV CD iij VW nav ume vv 4 Wall mount hole RESET Channel number 1 3 Battery compartment Battery compartment cover not shown 1 LCD display 2 LED Status indicator Bo mo BAR608HGA lab test R2 5 1 17 04 4 39 PM HEN 1 z GETTING STARTED 1 Press and hold MODE for 2 seconds to enter setting mode Batteries are not supplied with this product You will need to purchase 3 x UM 3 AA 1 5V alkaline batteries for Pe Press UP OPDOWN tochange settings the main unit and 2 x UM 4 AAA 1 5V alkaline batteries 3 Press MODE to confirm for the remote sensor Insert batteries before first use matching the polarity as Use the stand on the back of the product or mount it on shown in the battery compartment For best results a wall with a nail install batteries in the remote sensor before the main unit Press RESET after each battery change NOTE Do not use rechargeable batteries sa shows when ba
11. tteries are low UNIT sq LOCATION Main Indoor Temperature Humidity Area Remote Outdoor Temperature Humidity Area REMOTE SENSOR THGR122NX This product is shipped with a THGR122NX Thermo Hygro Sensor that collects Temperature and Humidity The front button panel is located inside the right portion data Data can be collected from up to 3 sensors of the main unit Slide it right to access the buttons Additional sensors sold separately BAR608HGA lab test R2 6 1 17 04 4 39 PM BAR608HGA lab test R2 7 Open the remote sensor battery compartment with a small Phillips screwdriver Insert the batteries matching the polarity as shown in the battery compartment SWITCH OPTION Channel Channel 1 3 If you are using more than one sensor select a different channel for each sensor Set the channel The switch is located in the battery compartment Place the sensor near the main unit Press RESET on the sensor Then press and hold MEM and CHANNEL on the main unit to initiate signal sending between the sensor and the main unit The reception icon on the main unit will blink for approximately 3 minutes while it is searching for the sensor Refer to the Sensor Data Transmission section for more information Close the remote sensor battery compartment Secure the sensor in the desired location using the wall mount or table stand For best results Insert the batteries and select the channel before
12. uipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 1 17 04 4 40 PM EN ga zZ DECLARATION OF CONFORMITY is in conformity with Part 15 of the FCC Rules Operation The information below is not to be used as contact for is subject to the following two conditions support or sales Please call our customer service number 1 This device may not cause harmful listed on our website at www oregonscientific com or interference on the warranty card for this product for all inquiries 2 This device must accept any instead interference received including interference that We may cause undesired operation Name Oregon Scientific Inc Address 19861 SW 95 Place Tualatin Oregon 97062 USA Telephone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the product Product No BAR608HGA Product Name Wireless Weather Station Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estate Phase 1 41 Man Yue St Hung Hom Kowloon Hong Kong 16 BAR608HGA lab test R2 16 1 17 04 4 40 PM BAR608HGA lab test back cover Ka 2004 Oregon Scientific All rights reserved P N 086 003312 012 12 29 08 10 40 PM
13. you mount the sensor Place the sensor out of direct sunlight and moisture Do not place the sensor more than 30 meters 98 feet from the main indoor unit Position the sensor so that it faces the main indoor unit minimizing obstructions such as doors walls and furniture Place the sensor in a location with a clear view to the sky away from metallic or electronic objects Position the sensor close to the main unit during cold winter months as below freezing temperatures may affect battery performance and signal transmission You may need to experiment with various locations to get the best results 1 17 04 4 39 PM Zz UU MT E EN Data is sent from the sensor s every 40 seconds The reception icon shown in the Temperature and Humidity Areas show the status ICON DESCRIPTION Main unit is searching for A gt CN sensors Z Atleast 1 channel has D ART been found Channel 1 is selected number ta will change depending on the Sensor you select shows in Outdoor The selected sensor cannot Temp Humidity Area be found Search for the sensor or check batteries To search for a sensor press and hold MEM and CHANNEL for 2 seconds NOTE If the sensor is still not found check the batteries obstructions and remote unit location NOTE Signals from household devices such as doorbells electronic garage doors and home security Systems may cause temporary reception