Home

NuTone 9194NT Air Conditioner User Manual

image

Contents

1. Refer to FIGURE 1 Follow these basic steps when installing this heater 1 Nail housing to studs 2 Connect power cable 3 Fasten heater assembly and grille to housing DRYWALL THERMAL OVERLOAD HEATER HOUSING BUILT IN r THERMOSTAT POWER CABLE FIGURE 1 INSTALL THE HEATER Refer to FIGURE 2 1 Remove heater assembly from housing Take out the four 4 screws shown and set heater assembly aside Refer to FIGURE 3 2 Attach housing to wall studs NOTE Locate housing at least 12 from floor on any adjacent walls Use the measuring guides on the sides of housing to position housing so that it will be flush with finished wall Nail the housing to studs through the hole and slot on both sides of housing NOTE In 24 on center stud construction framing in between studs is necessary WIRE THE HEATER Refer to FIGURE 4 1 Connect power cable to housing Attach electrical power cable to housing using appropriate connector Allow 6 of wire inside housing Secure ground wire to housing with grounding clip as shown Refer to FIGURE 5 and FIGURE 6 2 Wire the heater assembly Connect wires from heater assem bly to power cable wires Follow wiring diagram If heater is wired direct use the built in thermostat for tempera ture control OPTIONAL WIRING CONVERSIONS When using a separate wall control simply turn the heater s built in thermostat to its highest setting There is no need to disco
2. instalaci n defectuosa o instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita a un per odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitaci n antes mencionada puede no corresponderle LA OBLIGACION DE NUTONE DE REPARAR O REEMPLAZAR SIGUIENDO EL CRITERIO DE NUTONE DEBERA SER EL UNICO Y EXCLUSIVO RECURSO LEGAL DELCOMPRADOR BAJO ESTA GARANTIA NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSIGUIENTES O POR DANOS ESPECIALES RESULTANTES A RAIZ DEL USO O DESEMPENO DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consiguientes por lo que la limitaci n antes mencionada puede no aplicarse a usted Esta garant a le proporciona derechos legales espec ficos y usted puede tambi n tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza todas las garant as anteriores Para tener derecho al servicio de garant a usted debe a notificar a NuTone en la direcci n o al n mero de tel fono abajo b dar el n mero del modelo y la identificaci n de la pieza y c describir la naturaleza de cualquier defecto en el producto o pieza En el momento de solicitar servicio cubierto por la garant a usted debe presentar comprobaci n de la fecha original de
3. b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Product specifications subject to change without notice _ 4820 Red Bank Road Cincinnati Ohio 45227 Printed in U S A 3 03 4 Part No 99043274A Nulone INSTRUCCIONES DE INSTALACI N LEA Y CONSERVE ESTAS INSTRUCCIONES Calentador de la Pared MODELOS 9192NT 9194NT 9198NT INSTRUCCIONES DE SEGURIDAD IMPORTANTES ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO GOLPE EL CTRICO O LESI N A PERSONAS OBSERVE LO SIGUIENTE 1 Todo el trabajo electrico debe realizarse de acuerdo con los codigos electricos locales y o nacionales correspondientes Para su seguridad este producto debe ser conectado a tierra Si usted no esta familiarizado con los metodos de instalacion del cableado electrico obtenga los servicios de un electricista competente 2 Al hacer el cableado limpieza o dar servicio a esta unidad corte la energia y asegure el panel de servicio Si no hace esto es posible que otras personas o el termostato resuma la energia en forma inesperada lo que puede causar un golpe electrico mortal 3 Para evitar descarga el ctrica e NO instale la unidad en una ba era o recinto de ducha e NUNCA coloque un interruptor
4. screws Check thermal overload button marked RESET Heater will not operate unless this button is de pressed Refer to FIGURE 9 3 Install grille Place grille over heater and attach with four 4 screws Push knob onto thermostat stem 4 Attach security cover to grille optional When heater is in stalled in a public area without a separate wall control it is recommended that a Built in thermostat be set to desired temperature level b Thermostat knob be removed c Security cover be attached to grille with two 2 screws pro vided 5 Check operation Turn on power at service entrance Turn ther mostat to its highest setting and make sure heating element and blower come on Then turn it to its lowest setting and make sure element and blower shut off NOTE The fan delay prevents the fan from coming on until the element is hot Likewise it keeps the fan running until the element cools down USE AND CARE CAUTION DISCONNECT POWER AT SERVICE ENTRANCE AND LOCK OUT PANEL BEFORE CLEANING OR SERVICING UNIT Thermal Overload Protector Your heater is equipped with a manual reset thermal overload pro tector If heater fails to operate when thermostat is turned to its highest setting 1 Turn off power at service entrance 2 Remove knob and grille 3 Press button marked RESET This type of device is particularly useful compared to automatic reset devices because it encourages the user to find and correc
5. PURPOSE During this one year period NuTone will at our option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by us faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limita tion may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY nutone SHALL NOT BE LI ABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAM AGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty super sedes all prior warranties To qualify for warranty service you must a notify us at the address or telephone number below
6. compra NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 Especificaciones de producto conforme a cambio sin el aviso 4820 Red Bank Road Cincinnati Ohio 45227 Printed in U S A 3 03 8 o Part No 99043274A
7. p ngala dentro de la caja del calentador NOTA La cubierta se pueded colocar en su lugar antes o despu s de reinstalar el conjunto del calentador 2 Reinstale el conjunto del calentador Fije el conjunto del calentador a la caja con cuatro 4 tornillos Mire el bot n RESET de sobrecarga t rmica El calentador no funcionar a menos que el bot n est oprimido Refiera a la FIGURA 9 3 Instale la rejilla Coloque la rejilla sobre el calentador y f jelo con cuatro 4 tornillos Empuje la perilla en el v stago del termostato 4 Fije la cubierta de seguridad a la rejilla opcional Cuando se instala el calentador en un rea p blica sin un control de pared separado se recomienda a Graduar el termostato incorporado al nivel de temperatura deseado b Quitar la perilla del termostato c Fijar la cubierta de seguridad a la rejilla con dos 2 tornil los que se proveen 5 Compruebe el funcionamiento Conecte la energ a en la entrada de servicio Active el termostato en su graduaci n m s alta y compruebe que se activen el elemento de calor y el soplador Luego act velo en su graduaci n m s baja y compruebe que se apaguen el elemento y el soplador NOTA El retrasador del ventilador evita que el ventilador se ac tive hasta que el elemento est caliente Asimismo mantiene al ventilador en funcionamiento hasta que el elemento se enfr e USO Y MANTENIMIENTO CUIDADO DESCONECTE LA ENERGIA EN LA E
8. termostato incorporado o un termostato a distancia Seleccione el termostato de tensi n de l nea Modelo 86W o utilice el transformador rele Modelo 82 un termostato de bajo voltaje apropiado El conjunto Modelo 85NT est disponible para aplicaciones de montaje en superficie Adquiera estos accesorios en forma separada Proporcione al calentador la tensi n de l nea y cable de energ a el ctrica apropiados NOTA La energ a se puede tomar de un circuito cercano lo que depender del vatiaje requerido del calentador y amperaje nomi nal del circuito El calentador se puede convertir a mitad de vatiaje para evitar sobrecargar dichos circuitos MODELO VOLTIOS AMPS VATIOS BTU HR 9192NT 240 8 33 4 17 2000 1000 6827 3413 9194NT 240 12 50 6 25 3000 1500 10240 5120 9198NT 240 16 67 8 33 4000 2000 13653 6827 El cableado viene de f brica para las corrientes nominales en letras oscuras Secci n CONVERSIONES DE CABLEADO ORIGINAL encontrar las instrucciones de conversi n de vatiaje Refiera a la FIGURA 1 Al instalar este calentador siga estos pasos b sicos 1 Clave la caja en las vigas 2 Conecte el cable de energ a el ctrica 3 Fije el conjunto del calentador y la rejilla a la caja TN PARED DE YESO CAJA DEL BRECAR gii CALENTADOR TERMICA TERMOSTATO INCORPORADO gt CABLE DE ENERGIA ELECTRICA FIGURA 1 INSTALACION DEL CALENTADOR Refiera a la F
9. IGURA 2 1 Saque el conjunto de calentador de la caja Saque los cuatro 4 tornillos que se muestran y saque el conjunto del calentador Refiera a la FIGURA 3 2 Enganche la caja en las vigas de la pared NOTA Sit e la caja a una distancia por lo menos de 30 48 cm del piso o de cualquier pared adyacente Use las gu as de medida al costado de la caja a fin de colocarla a nivel con la pared terminada Clave la caja a las vigas a trav s del agujero y la ranura en ambos lados de la caja NOTA En una construcci n de vigas con centro de 60 96 cm 24 pulg se hace necesaria una armaz n entre las vigas CABLEADO DEL CALENTADOR Refiera a la FIGURA 4 1 Conecte el cable de electricidad a la caja Conecte el cable de energ a el ctrica a la caja usando el conector adecuado Deje 15 24 cm 6 pulg de cable dentro de la caja Fije firmemente a la caja el cable de conexi n a tierra con el sujetador tal como se muestra Refiera a la FIGURA 5 y 6 2 Cableado del conjunto de calentador Conecte los alambres del conjunto de calentador a los alambres de cable de energ a Siga el diagrama de cableado Si el calentador est cableado en forma directa use el termostato incorporado para el control de temperatura CONVERSIONES DE CABLEADO OPCIONAL Al usar un control de pared separado prenda el termostato incorporado al calentador en su graduaci n m s alta No es necesario desconectar el termostato incorporado Para evitar
10. NTRADA DE SERVICIO Y ASEGURE EL PANEL ANTES DE LIMPIAR O DAR SERVICIO A LA UNIDAD Protector de sobrecarga termica Su calentador cuenta con un protector de sobrecarga t rmica de reposici n manual Si el calentador no funciona cuando el termostato est activado en su graduaci n m s alta 1 Corte la energ a en la entrada de servicio 2 Saque la perilla y la rejilla 3 Oprima el bot n RESET Este tipo de dispositivo es especialmente til comparado con los de reposici n autom tica ya que alienta al usuario a encontrar y corregir la causa del sobrecalentamiento de una unidad al reajustar el protector A fin de evitar da os a la propiedad cuando se use este calentador para evitar congelamientos COMPRUEBE que el calentador funciona correctamente ANTES de dejarlo desatendido Un protector desconectado evitar que el calentador opere Limpieza Limpie el calentador con el cepillo redondo de su aspiradora Saque las acumulaciones grandes de polvo pelusa etc que puedan impedir el flujo de aire por el calentador Ese bloqueo disminuir la eficiencia y crear una posible condici n de sobrecalentamiento Para limpiar la rejilla use un trapo suave humedecido con limpidador para ventanas CUIDADO LAS PIEZAS METALICAS Y ELECTRICAS NUNCA SE DEBEN SUMERGIR EN AGUA PUENTE CONECTOR NEGRO T2 ELEMENTO DE CALOR U J l l SOBRECARGA l TERMICA A NEGRO ca TERMOSTATO J I l
11. Nulone Wall Heater MODELS 9192NT 9194NT 9198NT IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOW ING l All electrical work must be done in accordance with local or national electrical code as applicable For safety this product must be grounded If you are unfamiliar with methods of in stalling electrical wiring secure the services of a qualified elec trician When wiring servicing or cleaning this unit turn off power and lock out service panel Failure to do so could allow others or thermostat to turn on power unexpectedly which may cause fatal electrical shock To avoid electrical shock e Do not install unit in a tub or shower enclosure or any loca tion where it may come in contact with water e Never place a switch where it can be reached from a tub or shower Do not install this unit in an area where chemicals and other flammables are stored or used Explosion and fire may result CAUTION l 2 This product may ONLY be installed in a wall Do not mount in any other position Install heater at least 12 from floor or any adjacent vertical surface Do not locate heater behind a door furniture drapes etc where the air flow to the unit would be restricted Provide heater with an appropriately rated electrical circuit to prevent tripped breakers or blown fuses Do not connect heater to dimmer switch or speed control
12. RETRASADOR I DEL VENTILADOR l CALENTADOR CABLEADO EN FABRICA LINEA DE ENTRADA 240 208 VAC FIGURA 6 PUENTE CONECTOR NEGRO T2 ELEMENTO DE CALOR SOBRECARGA TERMICA A NEGRO x m l l l l l l l TERMOSTATO l l l l l l l l RETRASADO DEL VENTILADOR A CORTE EL CABLE PARA CALENTADOR EL CABLEADO TERMOSTATO EN FABRICA REMOTO LINEA DE ENTRADA 240 208 VAC FIGURA 7 PARTE SUPERIOR FRENTE DE CALENTADOR QUITE ESTE ALAMBRE DE CIERRE CALENTADOR CONVERTIDO A MITAD DE VATIAJE FIGURA 8 FIGURA 9 97009334 99390015 99030190 98006989 99271155 99270723 99270724 99400061 97008688 97008690 97008692 99150491 97008683 93270619 99260425 99160350 99030324 99080251 99080249 99020255 97013822 99150478 99091017 99360136 99110687 93150462 97013945 LISTA DE PIEZAS NUMERO DEPIEZAS DESCRIPCION Caja Sujetador de toma de tierra Retraso de ventilador Soporte del elemento Se requieren 2 Elemento de calefacci n Modelo 9192NT Elemento de calefacci n Modelo 9194NT Elemento de calefacci n Modelo 9198NT Manguito aislador Conjunto de alambre negro 74 93 cm Alambre de puente Soporte de sobrecarga t rmica Sobrecarga t rmica Alambre de energ a rojo Tornillo phillips cabeza grande 8 18 x 3 8 se requieren 14 Conjunto de placa de separaci n Sujetador del alambre se requie
13. S LIST PART NUMBER PART DESCRIPTION 97009334 99390015 99030190 98006989 99271155 99270723 99270724 99400061 97008688 97008690 97008692 99150491 97008683 93270619 99260425 99160350 99030324 99080251 99080249 99020255 97013822 99150478 99091017 99360136 99110687 93150462 97013945 Housing Grounding Clip Fan Delay Element Bracket 2 Required Heating Element Model 9192NT Heating Element Model 9194NT Heating Element Model 9198NT Bushing Black Wire Assembly 29 1 2 Black Jumper Wire Thermal Overload Bracket Thermal Overload Red Power Wire Screw 8 18 x 3 8 Ph Pan Head 14 Required Partition Plate Assembly Wire Clamp 3 Required Nut 8 32 Hex Keps 2 Required Screw 6 32 x 1 4 Ph Pan Head 2 Required Thermostat Motor Model 9198NT Motor Models 9192NT amp 9194NT Fan Blade Grille Screw 8 18 x 3 8 PH Truss Hd 4 Required Grille Logo Knob Security Cover Screw 8 18 x 5 8 Oval Head 2 Required Assembly Thermal Overload Includes Key Nos 9 10 amp 12 2 WARRANTY NUTONE ONE YEAR LIMITED WARRANTY NuTone warrants to the original consumer purchaser of our products that such products will be free from defects in materials or workman ship for a period of one year from date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED IN CLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FORA PARTICULAR
14. To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Please read specification label on product for further informa tion and requirement INSTALLATION INSTRUCTIONS READ amp SAVE THESE INSTRUCTIONS PLAN THE INSTALLATION This heater is intended to be used to supply supplemental heat from a wall location in new or existing construction Choose a location where edge of heater will be at least 12 from the floor or any adjacent vertical surface The heater can be operated using its built in thermostat or a re mote thermostat Choose either the Model 86W Line Voltage ther mostat or use the Model 82 Transfomer Relay with an appropriate low voltage thermostat The Model 85NT Kit is available for sur face mount applications Purchase these accessories separately Plan to supply the heater with proper line voltage and appropriate power cable NOTE Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit Heater can be converted to half wattage to avoid overloading such circuits MODEL VOLTS AMPS WATTS BTU HR 9192NT 240 8 33 4 17 2000 1000 6827 3413 9194NT 240 12 50 6 25 3000 1500 10240 5120 9198NT 240 16 67 8 33 4000 2000 13653 6827 Bold ratings are factory wired See OPTIONAL WIRING CONVERSIONS section for wattage conversion instructions
15. en un lugar que pueda ser alcanzado desde una ba era o ducha 4 NO instale esta unidad en un rea donde se almacenen o usen productos qu micos u otros productos inflamables De lo contrario pueden producirse explosiones e incendios CUIDADO 1 Este producto SOLAMENTE se puede instalar en una pared No lo monte en ninguna otra posicion 2 Instale el calentador por lo menos a 30 48 cm de distancia del piso o de alguna superficie vertical adyacente 3 NO COLOQUE el calentador detr s de una puerta muebles cortinas etc donde el flujo de aire a la unidad se encuentre restringido 4 Proporcione al calentador un circuito el ctrico de capacidad apropiada a fin de impedir la desconexi n de disyuntores o quemado de fusibles 5 No conecte el calentador a un variador de luz o control de velocidad 6 Para evitar da os al cojinete del motor e impulsores ruidosos y o desequilibrados mantenga la unidad de energ a alejada de roc os de yeso polvo de construcci n etc 7 Para m s informaci n y requisitos lea la etiqueta de especificaci n sobre el producto PLANIFICACION DE INSTALACI N Este calentador ha sido dise ado para proporcionar calefacci n adicional desde el cielo raso en una construcci n nueva o una ya existente Escoja un lugar en que el borde del calentador se encuentre por lo menos a 30 48 cm de cualquier superficie vertical adyacente Este calentador se puede poner en funcionamiento usando su
16. nnect the built in thermostat a Turn built in thermostat to highest setting b Remove knob c Fasten security cover to grille LINE VOLTAGE THERMOSTAT Refer to FIGURE 7 If wall mounted control is desired use the Model 86W Line Volt age Thermostat Purchase thermostat separately Cut blue wire Strip 12 of insulation from each end Connect wires from wall control to each stripped wire LOW VOLTAGE THERMOSTAT If wall mounted control is desired use a Model 82 Transfomer Relay with an appropriate low voltage thermostat purchase sepa rately Follow the mounting and wiring instructions packed with the controls HALF WATTAGE CONVERSION Refer to FIGURE 8 The heater will produce less heat and use less electricity if con verted to half wattage Remove the black jumper wire from the heating element and discard wire THERMAL OVERLOAD RESET BUTTON HEATER ASSEMBLY MOUNTING SCREWS THERMOSTAT FIGURE 2 NAIL HERE BOTH SIDES MEASURING GUIDES FIGURE 3 FIGURE 4 FIGURE 5 COMPLETE THE INSTALLATION 1 Install housing mask A housing mask has been provided to keep construction dust drywall spray paint etc from damag ing the heater Bend the flap on the mask and push it into the heater housing NOTE Mask can be put into place before or after heater assembly is reinstalled Remove mask before operation 2 Reinstall heater assembly Secure heater assembly to hous ing with four 4
17. ren 3 Tuerca Keps hexagonales de 8 32 se requieren 2 Tornillo cabeza m vil ph 6 32 x 1 4 se requieren 2 Termostato Motor Modelo 9198NT Motor Modelos 9192NT amp 9194NT Paleta de ventilador Rejilla Tornillo de ranura 8 18 x 3 8 PH Truss Hd se requieren 4 Logotipo de rejilla Perilla Cubierta de seguridad Tornillo cabeza ovalada 8 18 x 5 8 se requieren 2 Conjunto de sobrecarga t rmica Incluye Numero de Codigo 9 10 y 12 2 GARANTIA GARANTIA NUTONE LIMITADA POR UN A O NuTone garantiza al consumidor comprador original de sus productos que dichos productos carecer n de defectos en materiales o en mano de obra por un per odo de un a o a partir de la fecha original de compra NO EXISTEN OTRAS GARANTIAS NI EXPLICITAS NI IMPLICITAS INCLUYENDO PERO NO LIMITADAS A GARANTIAS IMPLICITAS DE COMERCIALIZACION O APTITUD PARA UN PROPOSITO PARTICULAR Durante el per odo de un a o y a su propio criterio NuTone reparar o reemplazar sin costo alguno cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso ESTA GARANTIA NO SEAPLICAA TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES Esta garant a no cubre a mantenimiento y servicio normales ni b cualquier producto o piezas que hayan sido utilizadas de forma err nea negligente que hayan tenido un accidente o que hayan sido reparadas o mantenidas incorrectamente por otras compa as que no sean NuTone
18. t the cause of overheating unit when resetting the protector To avoid property damage when using this heater to prevent freeze ups Make sure heater functions properly before leaving unattended A tripped protector will prevent the heater from operating Cleaning Clean the heater using the round brush tool on your vacuum cleaner Remove large accumulatoins of dust lint etc that might impede the flow of air through the heater Such blockage will lower its effi ciency and create a possible overheating condition To clean grille use a soft cloth which has been moistened with household window cleaner CAUTION METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER T1 y BLACK JUMPER T2 HEATING ELEMENT O e e x THERMAL z OVERLOAD L l l l l 1 a J BLK a p y m z THERMOSTAT FAN i DELAY T l BLU l a x a a FACTORY WIRED HEATER APA AAA AAA 240 208 VAC jsi FIGURE 6 A A ee ee ee T1 BLACK JUMPER T2 l _ _ _ _ S__ lt HEATING ELEMENT y U 0 J x THERMAL l a OVERLOAD A Buk x y m z THERMOSTAT FAN i DELAY i T l BLU l l a x x CUTWIRE a FOR FACTORY REMOTE l I WIRED THERMOSTAT HEATER eee eee AA AS 240 208 VAC LINE IN FIGURE 7 TOP FRONT OFHEATER REMOVE THIS JUMPER WIRE HEATER CONVERTED TO HALF WATTAGE FIGURE 8 FIGURE 9 PART
19. un ajuste descendente no deseado del termostato incorporado a Ponga el termostato incorporado en su graduaci n m s alta b Quite la perilla c Fije la cubierta de seguridad a la rejilla TERMOSTATO DE TENSI N DE L NEA Refiera a la FIGURA 7 Si se desea control montado en la pared use el termostato de tensi n de l nea Modelo 86W Compre el termostato por separado Corte el cable azul Quite 1 27 cm 2 pulg de aislamiento en cada extremo Conecte los cables del control de pared con cada cable desnudo TERMOSTATO DE BAJO VOLTAJE Si se desea control montado en la pared uso Modelo 82 un termostato de bajo voltaje apropiado compre por separado Siga las instrucciones de montaje y cableado que vienen con los controles CONVERSI N A MITAD DE VATIAJE Refiera a la FIGURA 8 El calentador producir menos calor y usar menos electricidad si se le convierte a mitad de vatiaje Saque del elemento de calor el alambre negro de puente y bote ste RESET DE SOBRECARGA TERMICA TORNILLOS DE MONTAJE DEL CONJUNTO DEL CALENTADOR TERMOSTATO FIGURA 2 CLAVE AQUI EN AMBOS LADOS GUIDAS DE MEDIDA FIGURA 3 DETALLE DEL SUJETADOR CLIP DE CONEXION A TIERRA FIGURA 4 FIGURA 5 COMPLETE LA INSTALACION 1 Instale la cubierta de la caja Se provee una cubierta de caja para evitar que el polvo de la construcci n rocios de yeso pintura etc da en el calentador Doble la aleta de la cubierta y

Download Pdf Manuals

image

Related Search

Related Contents

Sonorous Surefix 231  Fujitsu LIFEBOOK E734  Sea Gull Lighting 79136BLE-12 Installation Guide  Shure Microphone SM80 User's Manual  Honey-Can-Do SHO-01384 Instructions / Assembly      02/08/2013 Istruzioni di montaggio con radiocomando 944,22 Kb  User manual / Operating Instructions - El  Installation Manual - Hearth & Home Technologies  