1. System ID Enter the System ID number Disable Admin if required Number _ Auto Q Choose if you want the FastRAD to report alarms The default is report On Q off Report Enter the line number Enter a number between 001 and 999 Line J The default is 001 Alarm Enter the telephone number of the device where the FastRAD Number1 reports alarms Alarm Enter the telephone number of a second device where the Number 2 _________ FastRAD reports alarms Retry Enter the number of minutes the FastRAD waits before it retries Delay _ to report an alarm Enter a number between 1 and 99 Number Enter how many times a FastRAD tries to send an alarm after a of Retries __________ failed connection attempt Enter a number between 0 and 9 Alarm Low QO Choose the alarm baud number The default is High Baud Medium High Q Parity None Q Choose which parity setting the FastRAD uses The default is Odd Q None O Auto Choose if you want the FastRAD to answer incoming calls answer On must be ON to allow remote unassisted access The default is Off Answer Enter the line number An on core KSU line is recommended Line __________ Enter a number between 001 and 999 The default is 001 FastRAD Installation Guide 23 Answer Enter the number of seconds the FastRAD waits before answer Delay __________ ing a call Enter a number between 6 to 60 The default
2. TCM Port DB 9 Pin Barrel Power Connector Supply Plug LED Figure 2 KSU connection 6 Connect one end of the RJ 11 teladapt cord to the TCM port on the side panel of the FastRAD See Figure 2 7 Connect the other end to the RJ 11 teladapt jack to the KSU Make sure the cord is less than 800 m 2600 feet long Note A connection to the FastRAD DB 9 pin serial port is only required for a direct connection to a PC at the site FastRAD Installation Guide 8 Mounting the Before you mount the FastRAD select a location within 800 m FastRAD 2600 feet of the distribution block that is free of traffic dust and dampness Note You do not need to mount the FastRAD on the wall if it is only being used temporarily to program the KSU The FastRAD can be mounted either horizontally or vertically To mount the FastRAD on the wall 1 Attach the paper mounting template to the wall Make sure the template is even with the wall See Figure 3 Note This template is found at the center of this guide 130 mm 5 25 in 130 mm 5 25 po 130 mm 5 25 pulg Figure 3 Paper wall mounting template FastRAD Installation Guide Put the two screws in the wall leaving 10 mm 3 8 in of each screw exposed The marks on the template show where the two screws are placed After the screws are in place remove the paper template Li
3. IN RTEL NORSTAR FastRAD Figure 4 Mounting the FastRAD 3 Placethetwo keyhole slots at the back of the FastRAD over the screws and slide the FastRAD onto the screws When the FastRAD is securely mounted you are ready to start programming FastRAD Installation Guide 10 Programming the FastRAD Before you start make sure you have completed the FastRAD Programming Record found at the end of this guide This record must include the System ID Auto answer line number and Alarm reporting line number Table 2 shows the different programming parameters and their default values If your programming information does not specify a value for one of the fields assign it to the default value Note You must program the Required fields for the FastRAD to operate Also program any Optional fields that apply to your system Auto answer should be set to ON if unassisted remote access to the FastRAD is desired Programming Field Range Required Optional Default Password 8 to 10 digits Required none System ID Up to 10 digits Optional blank Auto answer line number 1 999 Required for auto answering Line 001 Alarm reporting line number 1 999 Required for alarm reporting Line 001 Local baud rate 300 1200 2400 4800 Optional 9600 9600 19200 Auto report alarms ON OFF Optional OFF Alarm number 1 up to 16 digits
4. Press CHHG The display shows Press dk The display shows CLEAR EKSF m Enter the telephone number for Alarm 2 Hum reteies 5 BACK CHHG zm Note If you are using the default setting s press HEXT and go to step 18 Press CHHG The display shows between 0 and 9 Hum retriesi CLEAR BESP ae Enter the number of retries This must be a number FastRAD Installation Guide 20 21 22 23 24 Press dk The display shows Retraminsa 15 BACE CHHG HET Press CHHG The display shows Retra minsi CLEAR EKSF DE Enter the number of minutes between retries This must be anumber between 1 and 99 Press DK The display shows Alarm baud High BACK CHMG HEXT To change the baud rate press CHHG until the desired baud rate appears The baud rate should match that of the alarm device s modem You have three choices Low Medium and High The default is High IMPORTANT Changing the baud rate is not required un less the alarm centre modem is connected to a slow de vice such as an old printer Selecting the Low setting limits the baud rate to less than 300 Selecting the Medium setting limits the baud rate to less than 1200 Selecting the High setting the baud rate is determined entirely by the FastRAD and the alarm centre modems Press HEST The display shows Farita Hone BACE CHHG HET To change
5. System overview of remote connection FastRAD Installation Guide Before you start Make sure you read and follow the instructions in this guide Make sure you have the necessary tools to complete the installation A Special parts check list is provided in this guide Make sure all equipment in the FastRAD package is accounted for A Package check list is provided in this guide Make sure the necessary environment and electrical con ditions are met An Environment check list and list of Electrical requirements are provided in this guide Important Only one FastRAD can be connected to a KSU Environment check list The FastRAD installation area should be O OOO clean free of dust dry and well ventilated between 0 and 50 Celsius 32 to 122 Fahrenheit non condensing relative humidity between 5 and 95 within 800 m 2600 feet of the Norstar KSU Note When using a Norstar 3X8 KSU the FastRAD must be installed within 305 m 1000 feet free of Bridge taps on the FastRAD KSU TCM loop free of Loading coils on the FastRAD KSU TCM loop Package check list Make sure the package contains m m m m the Norstar FastRAD an RJ 11 teladapt cord a power supply with a barrel connector a paper template for mounting FastRAD Installation Guide 4 Special check To begin an installation you need bi an operating Nortel two line display telephone for programming the F
6. The product may fall causing serious damage to the product This product should never be placed near or over a radiator or heat register This product should not be placed in a built in installation unless proper ventilation is provided Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock Never spill liquid of any kind on the product To reduce the risk of electric shock do not disassemble this product but have it sent to a qualified service person when service or repair work is required Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged or frayed b If the product has been exposed to rain water or liquid has been spilled on the product disconnect and allow the product to dry out to see if still operates but do not open up the product c If the product housing has been damaged d If the product exhibits a distinct change in performance Avoid using telephone equipment during an electrical storm There may be a remote risk of electric shock from lightning Do not use the telephone equipment to report a gas leak in the vicinity of the leak CAUTION To eliminate the possibility of accidental damage to cords plugs jack
7. such as a printer or terminal Before you begin an alarm programming session make sure the display shows RAD Admin If you do not have this display on the Norstar telephone follow the steps listed in Starting a Programming Session To program the FastRAD Alarm Reports 1 Press ALARM The display shows Auto rerort OFF BACK CHHG HEXT 2 Press CHHG to turn automatic alarm reporting on The display shows Auto report OH BACE CHHG HET 3 Press HET The display shows Refort line BAI BACE CHHG HEKT 4 Press CHHG The display shows Rerort linet CLEAR BESP OK 5 Enter the KSU line number the FastRAD uses for remote connections Refer to the Programming Record for the correct line number 6 Press HEST The display shows Alarm number 1 BACE SHOW HEST 7 Press SHOW to see where the FASTRAD reports its alarms The display shows Alarm number BACE CHHG HET FastRAD Installation Guide Press CHHG to enter the first alarm report telephone number The display shows CLEA BKSF Ok Enter the telephone number for Alarm 1 The display shows Press dk The display shows Press SHOW The display shows lt alarm number gt CLEAR BESP Ok Alarm number 2 BACK SHOW S HEAT Alarm number BACK CHHG HEAT If you do not want to enter a second alarm number press HET and go to step 14
8. the parity setting press EHHG until the desired setting appears The parity should match that of the alarm device s modem You have three choices None Odd and Even The default is None Press HEST The display shows RAD Admin GEH ALARM DATA FastRAD Installation Guide 17 Programming Data This completes alarm programming To continue programming FastRAD call handling refer to the next section Programming Data Data programming allows you to determine how many seconds the FastRAD waits before answering a call on an incoming KSU line This allows a line to be used normally during business hours and provides Auto answer capabilities after hours Auto answer must be set to ON to allow unassisted access to the FastRAD Before you begin programming make sure the display shows RAD Admin If you do not have this display on the Norstar telephone follow the steps in Starting a Programming Session To program the FastRAD s Data 1 Press DATA The display shows Auto answer OFF BACK CHHG HEAT J 2 Press CHHG to turn automatic answer ON The display shows Aute answer OH BACE CHHG HEST 3 Press HET The display shows Answer line Bai BACE CHHG HEST 4 Press CHHG The display shows Answer line 5 Enter the KSU line number the FastRAD uses for remote connections Refer to the Programming Record for the correct line number FastRAD Installa
9. 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference which may cause undesired operation While these rules are designed to provide reasonable protection there is no guarantee that interference will not occur in a particular installation You can determine whether interfer ence occurs by monitoring your receiving device while the equipment is connected and a phone call in place If problems are experienced Reorient or relocate the receiving TV or radio antenna where this may be done safely To the extent possible move the telephone system and the radio or television farther away from each other or connect the telephone system and the radio or television to outlets on separate cir cuits Consult the dealer or an experienced radio television technician for additional suggestions Note FCC registration does not constitute an expressed or implied guarantee of performance For Devices Intended to be Connected to the Public Switched Telephone Network FCC Registration Number This telephone equipment complies with Part 68 FCC Rules for connection to the Public Switched Telephone Network The FCC registration number appears on a label affixed to the KSU Your connection to the telephone line must comply with these FCC Rules Use only an FCC Standard network interface jacks an
10. Optional blank Alarm number 2 up to 16 digits Optional blank Retry delay 1 99 minutes Optional 15 minutes Number of retries 0 9 Optional 5 Alarm reporting baud rate Low Medium High Optional High Alarm reporting parity None Odd Even Optional None Auto answer ON OFF Optional OFF Answer delay 6 to 60 seconds Optional 18 seconds Table 2 Programming parameters and default values FastRAD Installation Guide 11 Starting a programming session The FastRAD cannot be used for remote or direct connections until the user password has been programed through Feature 9 This initial password programming must occur on site IMPORTANT There is no way to recover a lost or forgotten password or return to the default state A FastRAD is programmed from a Norstar two line display tele phone that is connected to the KSU Programming information is entered into the FastRAD using the dialpad on the telephone Follow the prompts that appear on the display Note You cannot start a programming session while you are on acall When a programming session is in progress press only the buttons indicated The programming session is termi nated when you press incorrect buttons or when you make or answer acall Only on aDR2 KSU can you put the programming session on hold to make or answer a call If you need to go back a step while you are programming press BACK or press and start again If you stop programming for more than three minu
11. astRAD 3 TXD Transmitted Data to FastRAD 4 DTR Data Terminal Ready to FastRAD 5 GND Ground 6 DSR Data Set Ready from FastRAD 7 RTS Request to Send to FastRAD 8 ICTS Clear to Send from FastRAD 9 IRI Ring Indicator from FastRAD Table 1 RS 232 Pin configuration FastRAD Installation Guide 6 Connecting When equipment and environment conditions have been veri the FastRAD fied you can begin connecting the FastRAD to the distribution bl ock Before you connect the FastRAD make sure the port works Attach a working Norstar two line display telephone to the port If the telephone operates the port is working To connect the FastRAD 1 Plug the barrel connector of the power supply into the power connector of the FastRAD and the other end into the wall outlet See Figure 2 This unit must be powered from a pluggable AN Type A Class 2 power source that is UL and CSA listed Check that the LED on the FastRAD unit is lit to confirm the power connection Locate the distribution block Mount the RJ 11 teladapt jack next to the distribution block Using twisted pair station wire connect the teladapt jack to a free station port at the distribution block Note Do not connect the FastRAD to port 101 This port is reserved for the prime set The FastRAD should be con nected to one of the on core station ports FastRAD Installation Guide
12. astRAD a screwdriver two round head size 8 wood screws 1 inch long a roll of tape or four tacks for mounting the template alist of programming parameters for the FastRAD a unique System identification ID number a unique password COvovovovov vv the Norstar ICS Remote Toolssoftware and documentation package Electrical Make sure the following electrical requirements are met requirements Q line voltage 120 V 102 127 Vac If you are using a PC at the site to test the FastRAD installation this package is required FastRAD Installation Guide Requirements for PC communication APCcommunicates with a FastRAD either through a modem or through an RS 232 cable A modem is used when the PC is situated at aremote location An RS 232 cable is used when the PC is situated near the FastRAD at the customer site When you use a PC at the customer site you must use a 9 pin cable to connect the PC to the RS 232 port on the FastRAD This connector is not supplied with the FastRAD Table 1 shows which pins are used to make a connection with the FastRAD Note The FastRAD modem supports V 32 V 32bis protocols only We recommend a baud rate of 9600 or greater be selected when connecting Norstar PC applications to the FastRAD remotely using a modem Refers to the PC Modem DTE speed Pin Name Function Direction 1 DCD Data Carrier Detect from FastRAD 2 RXD Received Data from F
13. ated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment WARNING Users should not attempt to make electrical ground connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate NOTICE The Ringer Equivalence Number REN assigned denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading Please refer to the installation instructions with the KSU for more details This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations as specified in the Industry Canada Standard ICES 003 Issue 2 Substitution of non approved equipment will void the Nortel warranty Address for warranty and repairs in Canada Nortel Networks 30 Norelco Drive Weston Ontario MAL 2X6 For more information call 1 800 4NORTEL FastRAD Regulations iV US Regulations Federal Communication Commission FCC Notice Please Read Carefully Radio TV Interference This equipment classified as a digital apparatus generates radio frequency inter ference and if not installed and used properly in strict accordance with the manufacturer s instructions may cause interference with receiving mediums This Class A equipment complies with Part
14. d FCC compliant line cord and plug to connect this equipment to premise wiring If a network interface jack is not already installed in your location you can order one from your telephone company Please refer to your Owner s Manual User s Guide for specific installation instructions FastRAD Regulations US Regulations continued In some states customers are permitted to install their own jacks The equipment may not be connected to a party line or coin toll telephone line Connection to Party Line Service is subject to state tariffs Contact the state public utility commission public ser vice commission or corporation commission for information It is no longer necessary to notify the Telephone Company of your system s Registration and REN numbers However you must provide this information to the telephone com pany if they request it If this equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required If advance notice is not practi cal the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in o
15. ed call is not accepted by the FastRAD ensure the FastRAD is not involved in a programming session Then ask the ICSRT user to attempt another operator assisted call FastRAD Installation Guide 21 Troubleshooting Troubleshooting the FastRAD installation is needed if you start a programming session and the display shows Inactive feature 1 Check the wiring at the distribution block 2 Make sure the Norstar port that the FastRAD is attached to is working 3 Check that the power LED on the FastRAD unit is lit to confirm the power connection 4 Refer to the appropriate Norstar Installer Guide for further diagnostic tests Note If the wiring at the distribution block has been discon nected the FastRAD can take up to two minutes to reset after the wiring is reconnected After you have checked all the wiring 1 Press Feature 9 J The display should show Enter password EXIT CHHG WEST 2 Press HEST The display shows RAD Admin GEH ALARM DATA If the display is still showing Inactive feature repackage the FastRAD and return it to the point of purchase FastRAD Installation Guide 22 Programming Complete the FastRAD Programming Record before you start programming Record FastRAD Programming Record Work Site Address Notes Telephone Number Installation Date Installer GENERAL
16. intended to alert the user to the pres ence of important operating and maintenance servicing instructions in the literature accom panying the product This symbol if applicable on the product is used to identify the following important information For equipment with internal power supplies Mains nominal AC voltage 110 120 V 50 60 Hz Mains nominal AC voltage 220 240 V 50 60 Hz For equipment with external power supplies Must be powered from aCSA certified and UL listed or CSA NRTL C certified Class 2 power source equipped with an appropriate mating connector Please refer to installation instructions for details For current ratings refer to product specific documentation and product labels FastRAD Regulations Important Safety Instructions Please Read Carefully When using your telephone equipment basic safety precautions should always be followed to reduce the risk of fire electric shock and injury of persons including the following 1 2 3 13 14 Read and understand all instructions Follow the warnings and instructions marked on the product Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning Do not use this product near water for example near a bathtub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool Do not place this product on an unstable cart stand or table
17. is 18 Local 300 U Choose the baud rate the FastRAD uses for the RS 232 port Baud Rate 1200 U The default is 9600 2400 U 4800 QU 9600 U 19200 A FastRAD Installation Guide 24 FastRAD Installation Guide 1 800 4NORTEL www nortel com norstar Norstar is a trademark of Nortel Networks Printed in Canada P0855601 Issue 05
18. numbers 1 Remain on the line and briefly explain to the dispatcher the reason for calling before hanging up 2 Perform such activities in the off peak hours such as early mornings or late evenings Substitution of non approved equipment will void the NORTEL warranty Address for warranty and repairs in the US Nortel Networks 640 Massman Drive Nashville TN 37210 For more information call 1 800 4NORTEL FastRAD Regulations vi FastRAD Regulations Introduction The Norstar Fast Remote Access Device FastRAD allows a personal computer PC running Norstar ICS Remote Tools ICSRT to communicate with a Key Service Unit KSU FastRAD also runs with Companion Diagnostics System CDS and Companion Manager The FastRAD e i located on site near either the KSU or the PC e receives calls from a PC via modem or PC direct connec tion e authorizes a PC to access a KSU connects a PC with the KSU e reports KSU alarms to an off site alarm center Refer to Figure 1 FastRAD Installation Guide Teladapt Jack NORTEL E I FastRAD E FIvivieisivimisivivisi Distribution block At the remote site the external Nie i line is connected to the FastRAD through a KSU line Norstar KSU The FastRAD and the modem are connected through the telephone network ICSRT PC Figure 1
19. on the local baud rate must be set to 9600 baud Press HEYT The display shows FAD Admin GEH ALARM DATA Press to end programming The FastRAD programming is completed You must now test the FastRAD to make sure it is operating properly FastRAD Installation Guide 20 Testing the FastRAD After the FastRAD installation and on site programming are completed you should test the FastRAD data transfer capabil ities To test the FastRAD make a connection between the PC running ICSRT and the KSU at the customer site If the PC is not located at the customer site and the FastRAD is not programmed with Auto answer ON you must phone the ICSRT operator and instruct the operator to establish a connection with the FastRAD In this case refer to Rerouting a call to the FastRAD If you are using a PC at the work site refer to ICS Remote Tools User Guide for instructions about connecting to the RAD The test is passed when the remote or local PC establishes a connection with the KSU If the FastRAD is programmed to report alarms you can test alarm calls by disconnecting the FastRAD power supply After a few seconds reconnect the power supply The FastRAD reports an alarm to the specified alarm connection centers Rerouting a Call to the FastRAD If the FastRAD is not set up to Auto answer a Central Office CO line ask the ICSRT user to set up an operator assisted call to your site If the operator assist
20. rder for you to make necessary modifications to maintain uninterrupted service Do not attempt to repair this equipment yourself If trouble is experienced with this equipment please refer to the repair and warranty information noted below If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved Signaling Method The equipment allows signaling in DTMFtones It can complete calls to local and long distance lines and can also complete long distance calls via computer phone systems such as MCI or SPRINT This equipment is capable of providing access to interstate providers of operator services through the use of access codes Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990 Ringer Equivalence Number The FCC Registration information on the product label includes a Ringer Equivalence Number REN which is used to determine the number of devices you may connect to your phone line Please refer to the installation instructions with the KSU for more details Hearing Aids The telephone station sets are compatible with hearing aids equipped with an appropriate telecoil and is compliant with the requirements of the Americans with Disabilities Act ADA Programming Emergency Numbers When programming emergency numbers and or making test calls to emergency
21. s and the tele phone equipment do not use sharp instruments during the assembly procedures Save these instructions FastRAD Regulations Canadian Regulations Industry Canada Notice Please Read Carefully The Industry Canada label identifies Public Switched Telephone Network PSTN certified equipment This certification means that the equipment meet certain telecommunications network protective oper ational and safety requirements Industry Canada does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facili ties of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Existing telecommunications company requirements do not permit their equipment to be connected to customer provided jacks except where specified by individual telecommunications company tariffs Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precau tion may be particularly important in rural areas Repairs to certified equipment should be made by an authorized Canadian maintenance facility desig n
22. tes the display returns to the date and time and you must restart programming from the beginning IMPORTANT You must wait 60 seconds before you attempt to program the FastRAD when the FastRAD is connected or restarted the power supply is disconnected or the KSU is restarted To start a programming session 1 Press Feature 9 09 The display shows Password EXIT CHHG HEST Note When the password has been changed the display shows Enter password Check the FastRAD installation wiring and start again if the display shows Inactive feature For more information refer to Troubleshooting later in this guide FastRAD Installation Guide Press CHHG to change your programming password Using the dialpad enter your new password Your pass word must be from eight to 10 characters long As you enter your password the display shows asterisks The display changes to show Confirm password When you re enter your password asterisks appear on the display Note We recommend you assign a password the first time you start a programming session You must assign a pass word before you can perform remote access Write down your password keep it in a safe place and avoid giving it to co workers This password can be changed at any time Press Ok to accept your new password The display changes to show Password again Press HEMT The display shows RAD Admin GEH ALARM DATA The RAD Admin displa
23. tion Guide Note In general the following points should be consid ered while choosing the FastRAD Auto answer line e If possible use an on core line for auto answering This allows remote access to the KSU even in the event of an expansion module failure e Usea line that is not often used for other purposes since the FastRAD will auto answer after a pre programmed delay e Choose only lines that are enabled Press DK The display shows Answer delan 18 EACK CHHG HEAT Press CHHG to change the number of seconds the FastRAD waits before answering an incoming data call The display shows Answer delat CLEAR BESP OK Enter the number of seconds you want the FastRAD to wait prior to answering an incoming data call This number must be between 6 and 60 Note The modem wait for carrier delay S Register 7 must be longer than the time it takes for the modem to dial the FastRAD Auto answer line plus the Answer delay time For example if it takes 10 seconds for the modem to dial in to the FastRAD and Answer delay is set to 50 seconds then the modem wait for carrier delay must be greater than 60 seconds Press OK The display shows Local baud 9600 BACE CHHG HET FastRAD Installation Guide 19 12 Press CHHG until the display shows the desired local serial port baud rate 300 1200 2400 4800 9600 or 19200 Note To use Norstar Manager in a direct connecti
24. to Menu NORTEL NORSTAR FastRAD Installation Guide Table of Contents Canadian amp US Safety Installation Instructions i For equipment with internal power supplies For equipment with external power supplies Important Safety Instructions ii Canadian Regulations iii Industry Canada Notice iii US Regulations iv Federal Communication Commission FCC Notice iv Introduction 1 Before you start 3 Special check list 4 Requirements for PC communication 5 Connecting the FastRAD 6 Mounting the FastRAD 8 Programming the FastRAD 10 Starting a programming session 11 General Programming 13 Programming Alarm Reporting 14 FastRAD Installation Guide ii Table of Contents Testing the FastRAD Troubleshooting Programming Record 20 21 22 FastRAD Installation Guide Canadian amp US Safety Installation Instructions Please Read Carefully WARNING To avoid electrical shock hazard to personnel or equipment damage observe the following precautions when installing telephone equipment 1 Never install telephone wiring during a lightning storm 2 Never install telephone jacks in wet locations unless the jack is specifically designed for wet loca tions 3 Never touch uninsulated telephone wires or terminals unless the telephone line has been discon nected at the network interface 4 Use caution when installing or modifying telephone lines The exclamation point within an equilateral triangle is
25. y is the main programming display This display must appear on the telephone before you can begin to program the FastRAD FastRAD Installation Guide General Programming General programming allows you to define the System ID number Before you begin entering general programming information make sure the display shows RAD Admin If you do not have this display on the Norstar telephone follow the steps in Starting a Programming Session To enter general FastRAD programming information 1 Press GEH The display shows ee BACK SHOW HEST 2 Press SHOW The display shows EACK CHHG HEAT Note If this is a first time installation we recommend the system ID number must be programmed to allow remote access If this is nota first time installation the display shows the last System ID entered 3 Press CHHG The display shows f CLEAR BESP GE 4 Using the dialpad enter the System ID number Note If you enter a wrong number press EKSF to delete the last number entered or CLEAR to erase all numbers entered 5 Press Ok to accept the System ID number This completes general programming To continue program ming alarm reporting refer to the next section Programming Alarm Reporting FastRAD Installation Guide 14 Programming Alarm Reporting The alarm programming session allows you to program the FastRAD to report alarms to the telephone number of a dedicated alarm center

Download Pdf Manuals

image

Related Search

Related Contents

DE Bedienungsanleitung FIN Käyttöohje EN Operating  User Manual for ULTR..  Montage- und Installationsanleitung Mounting and  「アクセスラインチェッカー[ALC-55U]で充電式電池を  price 1,488,000 1,488,000円  Viewsonic X Series VP2650wb  IA-573-A  ETC Desire Quick Guide D40, D40XT, D60  デジタルビデオカメラを用いた 月や小惑星による恒星の  UBZ-LK20 - Kenwood  