Nortel Networks 8010 Switch User Manual

image

Contents

1. CE Mark 11
2. F 25 to 70 C 13 to 158 F 85 maximum relative humidity noncondensing 95 maximum relative humidity noncondensing 3 024 m 10 000 ft 22 9 in 58 2 cm 17 5 in 44 5 cm 19 9 in 50 5 cm 85 Ib 39 kg 225 Ib 101 kg 2 per chassis 8 per fan tray One per fan tray Electrical Specifications System Line Frequency 47 to 63 Hz System with one power supply or two supplies in redundant configuration Input Volt Amperes Rating 1 236 VA maximum Input Power 1 112 W maximum Input Voltage 100 240 VAC Input current 12 to 6 A per line cord Thermal rating 3 792 BTU per hour maximum System with two power supplies nonredundant or three supplies in redundant configuration Electromagnetic Immunity RF Susceptibility Electrostatic discharge ESO Electrical Fast Transitions EFT B Electromagnetic Emissions Meets requirements of Safety Agency Approvals UL Listed CUL Approved CB report and certificate NOM Approved Input Volt Amperes Rating 2472 VA maximum Input Power 2224 W maximum Input Voltage 100 240 VAC Input current 12 to 6 A per line cord Thermal rating 7584 BTU per hour maximum IEC801 3 Level 2 1EC801 2 Level 2 3 1EC801 4 Level 1 2 USA FCC CFR 47 Part 15 Subpart B Class A Canada ICES 003 Issue 2 Class A Australia New Zealand AS NZS 3548 1995 Class A Japan VCCI V 3 97 04 Class A Taiwan CNS 13438 Class A EN 55 022 CISPR 22 1985 Class A
3. that bracket against the other side of the chassis 9103FA 9104FA 1 Hold each rack mounting bracket against 2 Insert the supplied flat head screws to fasten one side of the chassis Make sure the each bracket to the chassis attachment holes in the bracket match the holes in the chassis Installing the Chassis in a Rack Required tool Phillips screwdriver 9074FA 9075FA 1 Slide the chassis into the rack 2 Insert and tighten the rack mounting screws To complete the installation process refer to Installing the Power Supply Installing the Power Supply Required tool Phillips screwdriver 8957FA 8958FA 1 Ifnecessary remove the filler panel from a 2 Push the supply firmly into the bay power supply bay Note If you are installing a power supply in a new chassis be sure to remove the bag of dessicant from the middle power supply bay 8959FA 8960FA 3 Align and tighten the retaining screws 4 Connect the power cord to the power supply and to an AC power outlet that is on a circuit with no other equipment connected to it Connect each power supply in the chassis to a separate AC circuit 8964FA 5 Turn on the power switch Note In a newly installed chassis that requires two power supplies non
4. FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense European Requirements Only EN 55 022 Statement This is to certify that the Nortel Networks Passport 8010 Chassis is shielded against the generation of radio interference in accordance with the application of Council Directive 89 336 EEC Article 4a Conformity is declared by the application of EN 55 022 Class A CISPR 22 Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten in welchen F llen der Benutzer f r entsprechende Gegenma nahmen verantwortlich ist Attention Ceci est un produit de Classe A Dans un environnement domestique ce produit risque de cr er des interf rences radio lectriques il appartie
5. Part No 204518 B April 2000 4401 Great America Parkway Santa Clara CA 95054 Installing the Passport 8010 Chassis NORTEL NETWORKS Copyright O 2000 Nortel Networks All rights reserved April 2000 The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Nortel Networks NA Inc Trademarks NORTEL NETWORKS is a trademark of Nortel Networks Passport is a trademark of Nortel Networks All other trademarks and registered trademarks are the property of their respective owners Statement of Conditions In the interest of improving internal design operational function and or reliability Nortel Networks NA Inc reserves the right to make changes to the products described in this document without notice Nortel Networks NA Inc does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein USA Requirements Only Federal Communications Commission FCC Compliance Notice Radio Frequency Notice Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the
6. agement hardware For table or shelf installation make sure the surface will support at least 225 pounds 101 kilograms Make sure the area where you will install and use the Passport 8010 Chassis meets these environmental requirements Ambient temperature between 5 and 40 C 41 and 104 F Relative humidity between 5 and 85 noncondensing No nearby heat sources such as hot air vents or direct sunlight No nearby sources of severe electromagnetic noise No excessive dust Adequate power source within six feet one 15 Amp circuit required for each power supply Unpacking 9073FA 1 Passport 8010 Chassis 2 Power Supply one or more ordered separately 3 Documentation 4 Power cord optional 5 DB 25 to DB 9 adapter for use with comm port cable 6 Comm port cable for Passport 8132TX module purchased separately 7 Rack mounting brackets 8 Screws for brackets and equipment rack 9 Cable guides For detailed information about the comm port cable for the Passport 8132TX Switch Module refer to the documentation that was shipped with that module To purchase a replacement shipping carton assembly for the Passport 8010 Chassis contact the manufacturer Tharco at 1 800 772 2332 Attaching the Rack Mounting Brackets Required tool Phillips screwdriver Note Each bracket fits only one side of the chassis If the mounting holes do not line up between a bracket and the chassis try
7. he left side of the chassis so the bundled cables will not obstruct airflow to the right side of the chassis Fed pa 9105FA 9106FA 1 Loosen but do not remove the 2 Slide the guide onto the loosened screws rack mounting screws needed to install one cable guide 9107FA 3 Tighten the screws to secure the guide to the chassis Installing a Module For details about the operation of modules refer to the documentation that was shipped with each module Required tool Phillips screwdriver 9058FA 9059FA 1 Remove a filler panel from a module slot 2 Make sure the inserter extractor levers are rotated away from the front of the module 9060FA 9070FA 3 Align the module circuit board with the card 4 Rotate the inserter extractor levers to seat the guides in the chassis Slide the module into a backplane connectors slot in the chassis until the module touches the backplane connectors 9071FA 5 Align and tighten the retaining screws Chassis Specifications Environmental Specifications Operating temperature Storage temperature Operating humidity Storage humidity Operating altitude Physical Specifications Height Width Depth Weight Empty Weight Fully Loaded Cooling System Fan Trays Fans Thermal Sensors 0 to 40 C 32 to 104
8. ndra alors l utilisateur de prendre les mesures sp cifiques appropri es EC Declaration of Conformity This product conforms to the provisions of Council Directive 89 336 EEC and 73 23 EEC Go to http libra2 corpwest baynetworks com cgi bin ndCGl exe DocView on the Nortel Networks World Wide Web site for a copy of the Declaration of Conformity ii Japan Nippon Requirements Only Voluntary Control Council for Interference VCCI Statement CORB AURRE SERRE ERRE VCCI OHM KED YFA ARM E TT CORREALE CHATS CBE GEEBARITIE NICO ET TOBARRA OIR AS ZEKLDBRENSZTEMHBVET Taiwan Requirements Bureau of Standards Metrology and Inspection BSMI Statement LARA ERAHNEN ERE PRA T S RH ATE CGR AESH ERAN REM BNR Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus Passport 8010 Chassis does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique Passport 8010 Chassis respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada 111 iv About this Guide This guide provides information ab
9. out installing and using the Passport 8010 Chassis It includes the following information e Requirements for the operating environment of the chassis e Instructions for attaching rack mounting brackets e Instructions for installing the chassis e Instructions for installing one or more power supplies in the chassis e Instructions for installing cable guides e Instructions for installing a module in the chassis e Specifications for the chassis TM For information about available switch modules for this chassis consult your Nortel Networks Reseller For detailed information about setting up your network and using Nortel Networks switches refer to the documentation for the switch modules you install in the chassis Before You Begin The physical requirements for installing the Passport 8010 Chassis in an equipment rack are Adequate room 13 1 spaces is provided in an EIA or IEC standard 19 inch 48 2 centimeter equipment rack that is Bolted to the floor Braced if necessary Grounded Side rail dimensions are similar to this illustration Typical eal racks with these dimensions are the Chatsworth Products N Inc CPD rack and the B Line rack 9114FA At least 6 inches 15 2 cm exists between adjacent equipment racks to allow airflow and cooling Adequate front and side clearance exists for cables One module may have up to 48 ports Allow enough space at the left of the chassis for cables and cable man
10. redundant configuration you must turn on both units within 2 seconds of each other If you wait longer to turn on the second power supply both power supplies will turn off To correct this condition turn off both power supplies wait at least 30 seconds and turn both power supplies on again within 2 seconds Operational Notes for the Power Supply A Passport 8010 Chassis with up to five installed modules can operate with one installed power supply For a redundant power configuration install two power supplies A Passport 8010 Chassis with more than five installed modules requires a minimum of two power supplies for a nonredundant configuration A redundant configuration for such a chassis requires three power supplies In a chassis with a nonredundant power supply configuration if one power supply fails the system loses power and network connectivity In a chassis with two installed power supplies you can add a third power supply without powering down the chassis When you first install a Passport 8000 Series chassis that requires two power supplies nonredundant configuration you must turn on both power supply units within 2 seconds of each other If you wait longer to turn on the second power supply both power supplies will turn off To correct this condition turn off both power supplies wait at least 30 seconds and turn both power supplies on again within 2 seconds Attaching a Cable Guide Attach the cable guides to t