Home

Niles Audio PERS-3600B Radio User Manual

image

Contents

1. EXTERNAL SPEAKER JACK AND RELAY OUTPUT TERMINALS EXTERNAL SPEAKER BYPASS JUMPER FACTORY INSTALLED JAC 16VAC 1 25 AMP PLUG IN TRANSFORMER BATTERY FUSE COVER FUSE TYPE 2AG FUSE RATING 1 Zi TWO WAY DIGITAL VOICE AUDIO VOLUME VOLUME 4 BACKUP BATTERY INSTALLATION Ca O78 THE POWER SWITCH IS OFF gt N ON gt OFF PUSH THE RELEASE TABS IN AND SLIDE THE DOOR UPWARD CONNECT THE RED LEAD TO POSITIVE AND THE BLACK LEAD TO THE NEGATIVE BATTERY TERMINAL CAUTION CONNECTING THE BATTERY LEADS BACKWARDS WILL BLOW THE BATTERY FUSE FUSE TYPE 1 AMP 2AG BATTERY TYPE 12 VOLT 1 2 AMP HOUR SLIDE THE BATTERY INTO THE CASE AND a BATTERY DOOR IMPORTANT WHEN REPLACING THE BATTERY THE OLD BATTERY MUST BE RECYCLED DELIVER THE BATTERY TO AN APPROPRIATE RECYCLING FACILITY 3 TRANSFORMER INSTALLATION 6 APPLY POWER SELECT DIALING METHOD PLUG TRANSFORMER INTO AN UN SWITCHED AC OUTLET ON OFF NOTE THE DEFAULT DIALING METHOD IS TONE DIALING IF REQUIRED CHANGE THE DIALING METHOD BY PRESSING AND HOLDING THE HOME amp CANCEL BUTTONS FOR 3 SECONDS WHILE SWITCHING THE POWER ON TRANSFORMER WITH SCREW 7 BEEPS SOUND FOR PULSE DIALING 8 BEEPS SOUND FOR TONE DIALING FOR ALL TWO BUTTON TRANSMITTERS IT WILL PRESS CANCEL BUTTON WHEN IT IS ACTIVATE FOR 5 SECONDS INSTALLED 2 USING e CONSOLE ANNOUNCES WITH THE AW TH
2. ALLOW THE WIRE TO SLIDE INTO THE TERMINAL HOLE NOTE NOT BE USED IN UL INSTALLATIONS CONNECT WIRES TO RELAY TERMINALS NOTE THE CONSOLE IS SHIPPED WITH REMOVABLE LABELS COVERING SOME OF THE REAR CONNECTIONS CONSOLE TERMINALS 2 amp 3 TERMINAL BLOCK ARE A FORM A DRY CONTACT RELAY RATED 24 VOLTS AT 1 AMP MAXIMUM NOISEMAKER OR VISUAL INDICATOR EXTERNAL POWER SUPPLY 4 COMMON GROUND 5 EXTERNAL SPEAKER E gt o 5 a 2 F EN TERMINALS 4 amp 5 HAVE A FACTORY INSTALLED JUMPER DO NOT REMOVE UNLESS USING LISTED MODEL RSM 1 OR OTHER UL LISTED SPEAKER 18 SUPERVISORY CONDITIONS TRANSMITTER LOW BATTERY WHEN A TRANSMITTER SENDS A LOW BATTERY SIGNAL THE CONSOLE S STATUS INDICATOR WILL BLINK SLOWLY TRANSMITTER SUPERVISORY IF A TRANSMITTER PROGRAMMED AS SUPERVISED FAILS TO REPORT STATUS IN A 24 HOUR PERIOD THE CONSOLE S STATUS INDICATOR WILL LIGHT LOW CONSOLE BACKUP BATTERY THE CONSOLE WILL TEST ITS BACKUP BATTERY EVERY 8 HOURS IF THE BATTERY TESTS LOW THE POWER INDICATOR WILL BLINK SLOWLY WHILE THE CONSOLE CHARGES THE BATTERY WHEN TROUBLE EXISTS THE CONSOLE WILL ANNOUNCE THE CONDITION EVERY HOUR UNTIL CLEARED ERROR LOW SENSOR BATTERY CLEARING STATUS INDICATIONS PRESS THE CANCEL BUTTON TO CLEAR THE STATUS INDICATOR AND STOP THE ANNUNCIATION NOTE A TROUBLE CONDITION WILL LIKELY OCCUR AGAIN UNTIL THE PROBLEM IS FIXED THE CONSO
3. Alternately Ademco Contact ID format can be selected The telephone line is constantly monitored line failure and restoral will be locally announced by the Console optional through programming POWER SUPPLY Powered by a low voltage plug in transformer the Console has provisions for a rechargeable backup battery for operation during AC power outages A power switch allows for out of service storage of the Console without discharge of the battery The battery is recharged by the Console even if the POWER switch is off as long as the transformer is plugged in If the backup battery becomes low the POWER light will flash and the condition can be reported to the central station PROGRAMMING The Console is programmed using the RA 2400 remote access software available on CD and at Linear s Web site www linearcorp com Refer to the software s detailed instruction manual and built in help file for programming details OPERATION SUMMARY A variety of Linear s supervised DXS and non supervised DX format transmitters can be used with the Console Transmitters can be assigned to the following four functions EMERGENCY Portable supervised and non supervised pendant belt clip or wristband type transmitters Models DXT 41 DXT 42 DXT 61A DXS 21 DXS 23 DXS 62A and stationary supervised Model DXS 31 transmitters are used for medical alert applications When a medical alert transmitter is triggered the Console announces the emergency ala
4. NOT USED IN LISTEN ONLY AUDIO MODE THE 1 AND 3 KEYS CAN BE USED IN 2 WAY VOICE ACTIVATED MODE USING THEM WILL CAUSE THE SYSTEM TO SWITCH TO 2 WAY MANUAL MODE PRESSING 8 RESTORES 2 WAY VOICE ACTIVATED MODE PRESSING ANY KEY OTHER THAN 9 WILL EXTEND THE AUDIO TIME 90 MORE SECONDS 17 SPEAKERPHONE OPERATION PROGRAM THE CONSOLE TO ENABLE SPEAKERPHONE MODE NOTE SPEAKERPHONE MODE CAN ONLY BE USED ON INCOMING CALLS AND WILL NOT FUNCTION WHEN THE CONSOLE IS OPERATING FROM BACKUP BATTERY POWER ATTEMPTING TO ANSWER WHILE THE CONSOLE IS ON BACKUP POWER WILL CAUSE AN EMERGENCY ALARM WHILE THE TELEPHONE IS RINGING ACTIVATING AN EMERGENCY TRANSMITTER OR PRESSING THE HELP BUTTON WILL SEIZE THE TELEPHONE LINE THE SYSTEM WILL BEGIN 2 WAY VOICE ACTIVATED MODE FOR AUDIO COMMUNICATIONS WARNING THE CONSOLE WILL NOT BE ABLE TO REPORT AN EMERGENCY WHILE THE SPEAKERPHONE MODE IS ACTIVE NOTE TO REPORT AN EMERGENCY WHEN THE SPEAKERPHONE IS IN USE PRESS EITHER THE HELP BUTTON OR THE BUTTON ON AN EMERGENCY TRANSMITTER TO END THE PHONE CALL AND THEN PRESS ONE OF THESE BUTTONS AGAIN TO REPORT THE EMERGENCY THE CONSOLE WILL END AUDIO COMMUNICATIONS WHEN EITHER THE HELP BUTTON IS PRESSED ANY EMERGENCY TRANSMITTER IS ACTIVATED THE AUTO DISCONNECT TIMER RUNS OUT PROGRAMMABLE FOR 15 30 OR 60 MINUTES 19 OPTIONAL OUTPUT CONNECTIONS zi USE SMALL 0 SCREWDRIVER TO PUSH ON THE TERMINAL LOCKS TO
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e THE CONSOLE WILL ANNOUNCE ITS STATUS 2 PRESS AND HOLD THE HOME BUTTON FOR MORE THAN 10 SECONDS THE CONSOLE WILL RETURN TO STANDBY MODE 3 THE CONSOLE WILL ERASE ALL REMINDER MESSAGES AND PLAYBACK SCHEDULES AUTOMATICALLY AFTER 3 MINUTES 4 PRESS AND RELEASE THE CANCEL BUTTON TO EXIT TEST MODE 13 LOCAL PROGRAMMING WITH RA 2400 PERFORM THE STEPS DETAILED IN THE RA 2400 PERS REFERENCE GUIDE P N 224756 TO SET UP THE RA 2400 PROGRAM TO LOCALLY PROGRAM TH
6. AT IT IS READY TO EITHER LEARN TRANSMITTERS LEFT BUTTON BUTTON WHEN IT IS IT WILL ONLY 2 ACTIVATE TRANSMITTER 4 INSTALLED ACTIVATE CONSOLE ANNOUNCES yo WITH THE USING BOTH TRANSMITTER TYPE THEN RIGHT BUTTON BUTTONS REVERTS TO STANDBY MODE NOTE IF THE CONSOLE S MEMORY IS FULL THE CONSOLE WILL ANNOUNCE ERROR ZONES FULL FOR DXS 31 STATIONARY TRANSMITTERS DXS 62A REPEAT STEPS 1 amp 2 FOR ADDITIONAL WHEN IT IS INSTALLED WHEN IT IS INSTALLED TRANSMITTERS UP TO 16 TOTAL WITH THE JUMPER SET WITH THE JUMPER SET FORDELAY A NOTE PRESS CANCEL BEFORE TRANSMITTING TO RETURN TO STANDBY MODE WITHOUT ENTERING A TRANSMITTER THE CONSOLE WILL ANNOUNCE ITS STATUS THE CONSOLE WILL RETURN TO STANDBY MODE AUTOMATICALLY Sai onl WHEN TRANSMITTER IS LEARNED OR AFTER 30 SECONDS HAS ELAPSED AS EMERGENCY AS ACTIVITY FOR MODEL DXS 32 CUT JUMPER INSTANT TX FOR USE NOTE WRITE DOWN EACH TRANSMITTER S TYPE AND ZONE NUMBER AS AN ACTIVITY TX SEE DXS 32 INSTALLATION INSTRUCTIONS WHEN THE TRANSMITTER IS ADDED THE CENTRAL STATION WILL NEED TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER 9 INSTALLING MULTIPLE TRANSMITTERS 10 TESTING TRANSMITTERS ADDS MULTIPLE TRANSMITTERS PRESS TEST BUTTON 1 PRESS TEST BUTTON CONSOLE ANNOUNCES CONSOLE ANNOUNCES TEST MODE TEST MODE 2 PRESS TEST BUTTON AGAIN CONSOLE ANNOUNCES ITS 2 ACTIVATE EACH OF THE READY TO LEARN TRANSMI
7. E 1 DIAL THE NUMBER OF THE PHONE LINE THAT THE CONSOLE IS CONNECTED TO ALLOW IT TO RING THREE TIMES THEN HANG UP 2 WAIT ABOUT 10 SECONDS THEN CALL THE CONSOLE A SECOND TIME 3 WHEN THE CONSOLE ANSWERS A TONE WILL SOUND FOR ABOUT 8 SECONDS 4 WHEN THE TONE ENDS ENTER THE REMOTE AUDIO PASSWORD DEFAULT 1234 FOLLOWED BY THE KEY THE CONSOLE WILL BEGIN AUDIO COMMUNICATIONS 2 WAY DUPLEX 2 WAY MANUAL OR LISTEN ONLY DEPENDING ON THE CONSOLE S PROGRAMMING SEE SECTION 16 FOR AUDIO COMMUNICATION OPERATION DETAILS NOTE IF THE CONSOLE AUDIO IS SET TO NONE REMOTE AUDIO COMMUNICATIONS WILL NOT FUNCTION SPECIFICATIONS CODING FORMATS DX CODE 24 BIT A1D PPM DXS CODE 24 BIT A1D PPM POWER REQUIREMENTS PRIMARY SUPPLY BACKUP SUPPLY NORMAL OPERATING CURRENT ALARM OPERATING CURRENT BACKUP OPERATION DURATION BATTERY LIFE EXPECTED BACKUP SUPPLY OPERATING CURRENT BATTERY FUSE RF CHARACTERISTICS RECEIVER TYPE RF SENSITIVITY RADIO FREQUENCY MAXIMUM RANGE COMMUNICATOR COMMUNICATOR FORMATS DIALING DIALING DELAY REMOTE PROGRAMMING PASSWORD REMOTE COMMUNICATIONS PASSWORD ACCOUNT NUMBER LENGTH PRIMARY TELEPHONE NUMBER SECONDARY TELEPHONE NUMBER SUPERVISORY TELEPHONE NUMBER CONSOLE STATUS REPORT CONSOLE OPERATING TEMPERATURE HELP ALARM DURATION ACTIVITY TIMER PERIOD AUDIO RELAY OUTPUT Copyright 2008 Linear LLC 1 048 567 CODES 1 048 567 CODES 16 VAC 1 25 AMP PLUG IN TRANSFORMER 12 VOLT 1 2 AMP HO
8. E CONSOLE CONNECT THE MODEM S LINE JACK TO THE CONSOLE S LINE JACK PRESS THE TEST BUTTON MOMENTARILY e CONSOLE ANNOUNCES TEST MODE START A LOCAL CONNECTION WITH THE RA 2400 SOFTWARE NOTE CONSOLE WILL EXIT TEST MODE AUTOMATICALLY AFTER 3 MINUTES OR BY PRESSING THE CANCEL BUTTON WHEN RA 2400 CONNECTION TIMER STARTS COUNTING DOWN PRESS THE HELP BUTTON THE CONSOLE ANNOUNCES PHONE ON WHEN THE CONSOLE HAS CONNECTED PERFORM PROGRAMMING IN THE RA 2400 SOFTWARE SEND AND SAVE THE ACCOUNT PROFILE THEN DISCONNECT FROM THE CONSOLE 15 ACTIVITY TIMER OPERATION ENABLING THE ACTIVITY TIMER PRESS THE HOME BUTTON FOR 5 SECONDS TO TURN THE ACTIVITY TIMER ON NOTE THE ACTIVITY TIMER CAN BE ENABLED FOR 8 12 OR 24 HOURS OR DISABLED BY PROGRAMMING SECONDS THIS WILL ALSO TURN ON OFF REMINDER REPORTING IF REMINDER SCHEDULE TIME OUT REPORT IS ENABLED IN THE RA 2400 SOFTWARE ACTIVITY TIMER CAN BE DISABLED SEPARATELY IN RA 2400 ALARMS PROGRAMMING 2 ACTIVITY TIMER RUNNING THE HOME INDICATOR WILL LIGHT SHOWING THAT THE ACTIVITY TIMER IS ENABLED TIME RUNNING THE HOME INDICATOR WILL BLINK amp THE CONSOLE ANNOUNCES EVERY 10 SECONDS WHEN LESS THAN 15 MINUTES OF TIME REMAIN RESETTING ACTIVITY TIMER THE SUBSCRIBER NEEDS TO PRESS THE HOME BUTTON OR TRIGGER AN ACTIVITY TRANSMITTER BEFORE THE TIMER EXPIRES TO PREVENT AN INACTIVITY REPORT PRESSING THE HOME BUTTON RESTARTS
9. ICKLY WHEN AC IS ABSENT CONSOLE ON BATTERY POWER OFF IN TEST AND SETUP MODES CANCEL BUTTON e STOPS ALARM ADDS CANCEL TO AN ALARM REPORT IN PROGRESS e PRESS IMMEDIATELY AFTER EMERGENCY TO PREVENT REPORT CLEARS INDICATORS STOPS TROUBLE BEEPER PRESS FOR 5 SECONDS TO ADD ATRANSMITTER CLEARS REMINDER MESSAGE 3 TELEPHONE CONNECTIONS CONNECT THIS JACK TO THE TELEPHONE LINE RESIDENT S TELEPHONE JACK IF ACTIVITY TIMER IS OFF PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER AND REMINDER REPORT ON USED IN TEST MODE RECORD AND PLAYBACK REMINDER MESSAGES SENDING INDICATOR NORMALLY OFF FLASHES WHEN CONSOLE IS PLACING A CALL HELP BUTTON PRESS AND HOLD TO TRIGGER THE EMERGENCY ALARM e PRESS DURING RING FOR SPEAKERPHONE MODE PRESS DURING SPEAKERPHONE MODE TO DISCONNECT PRESS WHILE IN TEST MODE TO CONNECT THE CONSOLE TO A PC FOR LOCAL PROGRAMMING WITH THE RA 2400 SOFTWARE HOME BUTTON COVER HIDES THE HOME BUTTON IF THE ACTIVITY TIMER IS NOT USED REMOVE IF INSTALLED TO RECORD AND PLAYBACK REMINDER MESSAGES REAR OF CONSOLE CONNECT THIS JACK TO THE LOCAL TELEPHONE RESIDENT S LOCAL TELEPHONE OPTIONAL 2 REAR SIDE AND BOTTOM FEATURES BACKUP BATTERY ACCESS DOOR NOTE THE CONSOLE IS SHIPPED WITH REMOVABLE LABELS COVERING SOME OF THE REAR CONNECTIONS CONSOLE REAR SWITCH TEST BUTTON EXTERNAL MICROPHONE TERMINALS CONSOLE BOTTOM PHONE
10. IONS see ceara acea eee aaa cea aaa a va 5 OPTIONAL OUTPUT CONNECTIONS 5 OPTIONAL REMOTE SPEAKER MIC 5 NON VOICE PROMPT BEEP 6 65555 5555555 5 6 WIRELESS INSTALLATION 6 SPECIFICATIONS e eee ea e n aa ae a e na a na 6 LINEAR LIMITED WARRANTY 5 5 555555 555560 50 5 6 PRODUCT DESCRIPTION The PERS 3600B Console is a supervised wireless emergency reporting product designed for medical alert applications The table top Console provides pushbutton emergency assistance to anyone who desires additional security and peace of mind For the visually impaired each button on the Console is molded with braille characters to identify the button s function The Console can receive signals from up to 16 Linear wireless transmitters Activating a transmitter causes the Console s digital communicator to send the appropriate alarm report to the central monitoring station via the standard telephone network In addition to the central station report audible and visual indications occur and the alarm relay energizes during an emergency activation The emergency alarm can be triggered by the large HELP button on the top of the Console or with a wireless transmitter The fire alarm can be triggered by a wireless smoke a
11. LE WILL REPORT THESE SUPERVISORY CONDITIONS TO THE CENTRAL STATION IF ENABLED IN THE COMMUNICATOR PROGRAMMING AUTOMATIC FULL SYSTEM CONSOLE SUPERVISORY REPORTS CAN ALSO BE SENT AT 1 7 OR 30 DAY INTERVALS 20 OPTIONAL REMOTE SPEAKER MIC CONNECTIONS REMOVE JUMPER WIRE CONSOLE MAIN TERMINAL BLOCK 9 1 12 VDC 100 Ma O 2 RELAY NORMALLY OPEN 3 RELAY NORMALLY OPEN TO 4 GROUND 5 5 EXTERNAL SPEAKER CONSOLE MIC TERMINALS EXTERNAL MICROPHONE MICROPHONE COMMON Ble USE SHIELDED TWISTED PAIR WIRE FOR MICROPHONE NOTE REMOVE JUMPER WHEN USING A UL LISTED MODEL RSM 1 OR OTHER UL LISTED SPEAKER NOTE BE USED IN UL INSTALLATIONS SPKR SPKR MIC MIC RSM 1 TERMINAL BLOCK LINEAR MODEL RSM 1 TERMINALS 21 NON VOICE PROMPT BEEP LEGEND WHEN VOICE PROMPTS ARE DISABLED THE CONSOLE WILL SOUND BEEPS TO INDICATE VARIOUS CONDITIONS TRANSMITTER ADDED TO A SENSOR ZONE 1 LONG BEEP 2 BEEPS 3 BEEPS 4 BEEPS 5 BEEPS 6 BEEPS 7 BEEPS 8 BEEPS SENSOR ZONES FULL CONSOLE IN STANDBY MODE ACTIVITY TIMER ON CONSOLE IN STANDBY MODE ACTIVITY TIMER OFF CONSOLE IN TEST MODE CONSOLE IN LEARN TRANSMITTER MODE CONSOLE HAS ERASED ALL TRANSMITTERS PULSE DIALING HAS BEEN SELECTED FOR THE CONSOLE TONE DIALING HAS BEEN SELECTED FOR THE CONSOLE 22 REMOTE AUDIO COMMUNICATIONS TO ESTABLISH REMOTE AUDIO COMMUNICATIONS WITH THE CONSOL
12. PERS 3600B PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION amp OPERATION INSTRUCTIONS Linear Building On Innovation USA amp Canada 800 421 1587 amp 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com CONTENTS CONTROL AREA FEATURES scene oie Ca ee eee 8 459855 1 REAR SIDE AND BOTTOM FEATURES 1 TELEPHONE seo teed esa ce a e aa 1 BACKUP BATTERY INSTALLATION 1 TRANSFORMER 1 2 APPLY POWER SELECT DIALING METHOD 2 TRANSMITTER INSTALLATION 2 INSTALLING SINGLE 2 INSTALLING MULTIPLE 3 TESTING TRANSMITTERS i500 ccc eee ae e na aa a aa 3 ERASING TRANSMITTERS 0 22 55 555 056006586669 698555 660 3 RECORDING REMINDER MESSAGES 3 LOCAL PROGRAMMING WITH RA 2400 4 SYSTEM OPERATION i arnunt s Meade 4 ACTIVITY TIMER OPERATION gt 2 ceea ee 5959999555 es 4 AUDIO OPERATION si e e ea ae aa eat aaa a we a aa 4 SPEAKERPHONE OPERATION 5 SUPERVISORY CONDIT
13. THE TIMER 14 SYSTEM OPERATION CONSOLE STANDING BY HOME LIGHT SHOWS ACTIVITY TIMER STATUS THE OTHER CONSOLE LIGHTS ARE NORMALLY OFF PRESS AND MOMENTARILY HOLD THE HELP BUTTON OR ACTIVATE AN EMERGENCY TRANSMITTER PRESS TRANSMITTER BUTTON FOR AT LEAST 2 SECONDS CONSOLE ENDING LIGHT IN ALARM R T gt FLASHES DURING COMMUNICATION T 1 z PRESS CANCEL TO STOP THE ALARM ADDS CANCEL TO ALARM REPORT IN PROGRESS THE CONSOLE ANNOUNCES EMERGENCY UNTIL THE CANCEL BUTTON IS PRESSED CENTRAL STATION REPORT IS COMPLETE OR THE SIREN TIME EXPIRES 16 AUDIO OPERATION PROGRAM THE CONSOLE FOR THE DESIRED AUDIO MODE 1 LISTEN ONLY 2 2 WAY MANUAL 3 2 WAY VOICE ACTIVATED DUPLEX 2 AFTER THE CENTRAL STATION OPERATOR ACKNOWLEDGES THE COMMUNICATOR S REPORT THE CONSOLE WILL STOP ITS LOCAL ALARM AND SWITCH TO THE SELECTED AUDIO MODE FOR 90 SECONDS AUDIO OPERATION CAN ALSO BE ESTABLISHED BY CALLING THE CONSOLE TWICE AND KEYING IN THE FOUR DIGIT REMOTE AUDIO PASSWORD FOLLOWED BY THE KEY SEE SECTION 22 CENTRAL STATION OPERATOR OR AUDIO CALLER USE THESE KEYS ON A TELEPHONE SET TO CONTROL THE CONSOLE S AUDIO MODE IN CENTRAL STATION CONNECT A TELEPHONE TO THE SAME TELEPHONE LINE AS THE CENTRAL STATION RECEIVER PRESS 9 DISCONNECT THE CALL MANUAL AUDIO MODE PRESS 1 TO TALK 2 WAY PRESS 3 TO LISTEN THE 1 AND 3 KEYS ARE
14. TTERS CONSOLE S TRANSMITTERS ONE AT A TIME NOTE EACH TIME THE TEST BUTTON IS PRESSED IN THE ADD TRANSMITTER MODE THE CONSOLE WILL BE READY TO INSTALL A TRANSMITTER IN THE NEXT AVAILABLE SENSOR ZONE LOCATION THE CONSOLE WILL ANNOUNCE THE SENSOR ZONE LOCATION NUMBER ACTIVATE TRANSMITTER CONSOLE ANNOUNCES TAE TRANSMIMER THE CONSOLE WILL ANNOUNCE NOTE IF THE CONSOLE S MEMORY THE TRANSMITTER S TYPE IS FULL THE CONSOLE WILL ANNOUNCE AND ZONE NUMBER AND ANY ERROR ZONES FULL SUPERVISORY CONDITIONS 2 REPEAT STEPS 2 8 3 FOR FOR THE TRANSMITTER ADDITIONAL TRANSMITTERS UP TO 16 TOTAL 5 PRESS CANCEL TO RETURN TO STANDBY MODE 0 THE CONSOLE WILL ANNOUNCE ITS STATUS THE CONSOLE WILL RETURN TO STANDBY MODE PRESS CANCEL TO RETURN TO STANDBY MODE AUTOMATICALLY AFTER 3 MINUTES THE CONSOLE WILL ANNOUNCE ITS STATUS NOTE WRITE DOWN EACH TRANSMITTER S TYPE AND ZONE NUMBER WHEN THE TRANSMITTER IS ADDED THE CENTRAL STATION WILL NEED THE CONSOLE WILL RETURN TO STANDBY MODE TO KNOW THE TYPE AND REPORTING ZONE FOR EACH TRANSMITTER AUTOMATICALLY AFTER 3 MINUTES 11 ERASING TRANSMITTERS 12 RECORDING REMINDER MESSAGES RECORDING REMINDER MESSAGES A 1 PRESS AND RELEASE THE TEST BUTTON CAUTION ALL TRANSMITTERS WILL BE ERASED 2 PRESS AND HOLD THE HOME BUTTON FOR 5 SECONDS BE READY TO RECORD 3 RECORD UP TO A 15 SECOND MESSAGE SPEAK AT NORMAL VOLUME TWO FEET FROM CONSOLE 1
15. UR BATTERY 120 mA 190 mA 30 HOURS MINIMUM 3 YEARS 40 mA 1 AMP TYPE 2AG DUAL DIVERSITY SUPERHETERODYNE 100 dBm TYPICAL 315 Mhz 400 FEET LINE OF SIGHT OPEN RANGE UL LISTED FOR 150 FEET 4 BY 2 GENERAL OR POINT TO POINT ADEMCO CONTACT ID UL TESTED WITH SURGARD SGMLRG DG CENTRAL STATION RECEIVER TONE OR PULSE 0 OR 15 SECONDS 6 DIGITS 4 DIGITS 4 DIGITS 20 DIGITS 20 DIGITS 20 DIGITS OPTIONAL 1 7 OR 30 DAY REPORT NOTE THE INSTALLER MUST VERIFY COMPATIBILITY BETWEEN THE PERS 3600B AND THE UL LISTED DIGITAL ALARM COMMUNICATOR RECEIVER 32 120 F 0 49 C 1 30 MINUTES 8 12 OR 24 HOURS LISTEN ONLY 2 WAY MANUAL 2 WAY VOICE ACTIVATED DUPLEX SPEAKERPHONE N O 24 VOLT AC DC 1 AMP MAXIMUM NEC CLASS II CIRCUITRY 23 WIRELESS INSTALLATION TIPS WALLBOARD AND WOOD STUDS CONSTRUCTION MATERIALS WILL AFFECT RADIO RANGE 90 100 OF FULL POWER CONCRETE WITH STEEL REINFORCEMENT OR METAL LATH AND PLASTER LIGHT CONCRETE OR BRICK 65 95 OF FULL POWER 10 70 OF FULL POWER CENTRALLY LOCATE CONSOLE CONSOLE LOCATION WILL AFFECT RADIO RANGE TRANSMITTERS AT THE OTHER END OF THE HOUSE MIGHT BE TOO FAR AWAY LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve 12 months This warranty extends only to wholesale customers who buy direct from Linear or through Linears normal distribu
16. he central station The activity timer can be turned on or off at the Console or through programming AUTOMATIC FULL SYSTEM TEST The Console can be programmed to perform a full system test daily weekly or monthly The automatic full system test can also be disabled As long as all system components are operational the system test report will be sent at the programmed interval The full system test report will NOT be sent if any system component transmitter Console phone line is not fully functional EMERGENCY 41 DXT 42 CARBON MONOXIDE ACTIVITY DXT 61A DXS 21 DXS 23 DXS 62A NOTE COMPATABILITY WITH THE PERS 3600B HAS NOT BEEN VERIFIED BY UL DXS 31 32 DXS 54 UP TO 16 TRANSMITTERS TOTAL CAN BE USED WITH EACH CONSOLE NOTE NOT A UL LISTED DEVICE 1 CONTROL AREA FEATURES HOME INDICATOR LIGHTS WHEN ACTIVITY TIMER IS ON e LIGHT IS OFF WHEN ACTIVITY TIMER IS OFF STATUS INDICATOR NORMALLY OFF e LIGHTS WHEN ANY TRANSMITTERS ARE MISSING SUPERVISORY BLINKS SLOWLY WHEN ANY TRANSMITTERS HAVE A LOW BATTERY BLINKS SLOWLY WHEN LESS THAN 15 MINUTES REMAIN ON THE ACTIVITY TIMER BLINKS QUICKLY WHEN THE ACTIVITY TIMER HAS EXPIRED HOME BUTTON PRESS TO RESET ACTIVITY TIMER PRESS FOR 5 SECONDS TO TURN ACTIVITY TIMER AND REMINDER RPT OFF POWER INDICATOR LIGHTS WHEN AC IS PRESENT BLINKS SLOWLY WHEN BATTERY IS CHARGING BLINKS QU
17. larm ACTIVITY TIMER The optional activity timer can be set for 8 12 or 24 hour operation or disabled The emergency alarm will trigger automatically if the time set elapses before an activity transmitter is triggered or the Console s HOME button is pressed VOICE PROMPTS To simplify operation the Console can speak to the subscriber with its built in digitally synthesized voice The Console will say emergency fire CO alarm timer done soon and other system operation setup and supervisory prompts from a 50 word vocabulary If necessary the voice option can be disabled AUDIO COMMUNICATIONS The Console can perform 2 way voice activated duplex 2 way manual and 1 way listen only audio communications through the Console s built in high sensitivity microphone and speaker Communications with central station monitoring personnel starts after an alarm Communications can also be started without any subscriber action by calling the Console twice from any telephone and keying in a four digit password REMINDER MESSAGES As a special feature the PERS 3600B Console can record and play up to approximately eight 15 second audio reminder messages The reminder messages can be used to help the subscriber remember to take medications call someone get ready for an appointment etc Each message is controlled by a real time clock and can be programmed via the RA 2400 software to play daily every other day weekl
18. rm and an emergency report is sent to the central station The emergency alarm can also be triggered by pressing the Console s HELP button FIRE Supervised Model DXS 73 wireless photoelectric smoke alarm triggers the fire alarm When the fire alarm is activated the Console announces the fire alarm and a fire report is sent to the central station CARBON MONOXIDE CO Supervised Model DXS 80 wireless carbon monoxide detectors trigger the CO alarm When a carbon monoxide alarm is activated the Console sounds a repeated series of four beeps and a carbon monoxide report is sent to the central station ACTIVITY Supervised switch or motion triggered transmitters Models DXS 31 DXS 32 and DXS 54 can be used for ensuring human activity The DXS 54 motion detector will monitor room activity The DXS 31 and DXS 32 transmitters can be wired to a pushbutton or switch for manual activity monitoring As long as a signal is received at least once every 8 12 or 24 hours programmable an alarm will not be triggered 15 minutes before the programmed time expires the HOME indicator will start blinking and the Console will announce every ten seconds that the timer will run out soon The activity timer can be reset with a signal from one of the activity transmitters or by pressing the HOME button on the Console Failure to reset the activity timer within the programmed time period will trigger the Console s emergency alarm and send an inactivity report to t
19. tings 5 Changes or modifications to the device may void FCC compliance e Infrequently used radio links should be tested regularly to protect against undetected interference or fault e general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer and these facts should be communicated to the ultimate users 228305 A
20. tion channels Linear does not warrant this product to consumers Consumers should inquire from their selling dealer as to the nature of the dealer s warranty if any There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property revenue or profit or cost of removal installation or reinstallation All implied warranties including implied warranties for merchantability and implied warranties for fitness are valid only until the warranty expires This Linear LLC Warranty is in lieu of all other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Contact Linear Technical Services at 1 800 421 1587 for an RPA and other important details IMPORTANT WIRELESS INFORMATION Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling However there are some limitations which must be observed e For U S installations only The radios are required to comply with FCC Rules and Regulations as Part 15 devices As such they have limited transmitter power and therefore limited range e receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies regardless of code set
21. y or monthly Reminder messages are played and repeated in three minute intervals for either 15 or 30 minutes programmable until canceled Messages can also be programmed for single play BUILT IN SPEAKERPHONE The Console can be programmed to act as a remote controlled speakerphone With the speakerphone mode enabled the Console will monitor the telephone line for an incoming call Activating any emergency transmitter or the Console s HELP button while the telephone is ringing will cause the Console to seize the line and begin speakerphone communications Activating any emergency transmitter or HELP button during the call will disconnect the line The Console will auto disconnect after 15 30 or 60 minutes programmable TRANSMITTER SUPERVISION Supervised transmitters regularly send status reports to the Console and low battery reports when their batteries are low When the Console receives a low battery report the STATUS indicator blinks If the Console fails to receive a status report from a transmitter for a period of 24 hours the STATUS indicator will light All supervisory conditions can sound a local annunciation and be reported to the central station optional through programming DIGITAL COMMUNICATOR The Console s digital communicator can route calls to three telephone numbers primary secondary and supervisory General reporting codes and individual sensor reporting codes are programmable for the 4x2 format

Download Pdf Manuals

image

Related Search

Related Contents

〇ရ安全データシート  MANUALE TECNICO SISTEMI SOLARCOM A CIRCOLAZIONE  Zanussi ZA 98/3 W Instruction Booklet  取扱説明書 TLMS-5500RV TLMS-5500RV-LR  Analogue Signal Transmitter AST3    SYBA CL-SPK20138 soundbar speaker  

Copyright © All rights reserved.
Failed to retrieve file