Home
NEC NDA-24233 Network Card User Manual
Contents
1. pl 00 FF Manufacturer code 49 NEC Else other vendor p2 00 FF Division code 00 NEC Else other division of NEC p3 00 FF Unit code 00 TC5000EX7 Ol TCS5000EX 10 02 MMVC 03 VL128 384 10 MCUS000A Else Reserved p4 OO FF Own Capability code D7 D6 D5 D4 D3 D2 D1 D0 DO Kanji Display Capability 0 Off 1 On D1 Composite Screen Display Capability 0 Off 1 On D2 H281 Camera Control Capability 0 Off 1 On p5 00 FF Reserved NDA 24233 Issue 2 Page 3 63 Console Command List VisuaLink 128 384 Engineering Guide IMOD Report of Common Mode in Communication 24 3 Description Reports the negotiated mode during a communication Command Format RMOD pl p2 p3 p4 p5 p6 p7 p8 pl B 2B 3B 4B 5B 6B communication speed p2 56 64 network TYPE p3 QCIF FCIF video format p4 ULW SBA LDC OFF audio mode ps 4 0 6 4 14 4 24 0 VMLP OFF MLP speed p6 ON OFF MBE capability p7 ON OFF T120 capability P8 1 2 4 8 9 6 14 4 O0FF LSD SPEED Page 3 64 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide 3 25 Alarm Status Report Command Console Command List RALM Alarm Status Change Report 1 of 2 25 1 Description Reports the VisuaLink alarm status This is reported when alarm and loopback status 1s changed Command Format RALM pl p2 p3 p4 p5 p6 pl 00 FF CPU VIDEO alarm p2 00 FF
2. NDA 24233 Issue 2 Page 3 21 Console Command List VisuaLink 128 384 Engineering Guide 3 5 ISDN Registering Setting Command NDSS Registering My Number 5 1 Description Registers a local dial number In a communication a local dial number is reported to the remote site at a call origination The local number to report at this time is registered The number of digit that can be registered is 20 digits for dial number and 8 digits for a sub address at a maximum Command Format NDSS p1 p2 p3 pl L11 line 1 dial No 1 L12 line 1 dial No 2 L21 line 2 dial No 1 L22 line 2 dial No 2 L31 line 3 dial No 1 L32 line 3 dial No 2 p2 0 9 dial Number within 20 digits sub address within 8 digits z dial number sub address separating code Off Registration Deleted Local Dial Format dial number Sub Address p3 0 9 Note 1 If pl is omitted the default is L11 Note 2 If VL128 setting L21 to L32 results in error Response Normal Response OK Error Response ERROI Page 3 22 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide NDSR Checking My Number Registration Console Command List 5 2 Description Command Format Response Note If pl is omitted the default is L11 Checks the current local dial number setting In a communication a local dial number is reported to the remote site at a call origination This is used to check a local dial number set by a NDSS command
3. NCRN pl p2 p3 pl xx speed dial call xx speed dial number 0 9 dial number within 20 digit Sub address within 8 digit F address sub address ch1 ch2 separating code R redial p2 B 64 kbps 2B 2x64 kbps 3B 192 kbps 4B 256 kbps 5B 320 kbps 6B 384 kbps TEL telephone p3 64 P x64k network 56 Px56k network Note 1 With p1 speed dial p2 and p3 are omitted Note 2 When p3 is omitted 64 is set Note 3 When p3 TEL p4 is omitted Response Normal Response OK Error Response ERRO1 ERRO05 ERR33 ERR34 ERR35 ERR41 ERR43 ERR44 ERR45 ERR47 ERR48 ERR86 ERR87 Note If VL128 setting 3B 6B in p1 results in error Page 3 52 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List NDSC Requesting Disconnection 19 2 Description Command Format A disconnect in an BRI ISDN call This command is used to execute a disconnection request and ending communication NDSC Response Normal Response OK Error Response ERROI ERR41 ERR46 ERR48 ERR87 NCIC Incoming Call Permit Reject 19 3 Description Permits or rejects incoming call on the BRI ISDN live When a manual Command Format Response incoming call mode is selected with a SINC command NCIC command permits or rejects an incoming call for NINC indication NCIC pl pl YES permit NO reject Normal Response OK Error Response ERROI ERROS5 ERR41 ERR42 ERR87 N
4. NDSR p1 pl Lil L12 L21 L22 L31 L32 line 1 dial No line 1 dial No line 2 dial No line 2 dial No line 3 dial No line 3 dial No Normal Response p1 p2 OK pl Lil L12 L21 L22 L31 L32 p2 0 9 xK NOR Nee Ne No Entry Local Dial Format dial number Sub Address Error Response ERROI ERRO05 ERRO7 ERR41 ERR87 line 1 dial No line 1 dial No line 2 dial No line 2 dial No line 3 dial No line 3 dial No 1 Z 1 ae 1 ar dial Number within 20 digits sub address within 8 digits dial number sub address separating code Registration Deleted NDA 24233 Issue 2 Page 3 23 Console Command List MDST Registering Speed Dial VisuaLink 128 384 Engineering Guide 5 3 Description Command Format Response VisuaLink can register a maximum of 130 speed dial numbers A dial number that can be registered shall be 20 digit at a maximum with a sub address of a maximum of 8 digits and a line speed must be set MDST p1 p2 p3 p4 p5 pl p2 p3 p4 p5 XXX 0 9 speed dial number xxx speed dial number 1 130 dial Number within 20 digits sub address within 8 digits address subaddress Ch1 Ch2 separating code Registration Deleted 64 kbps 2x64 kbps 192 kbps 256 kbps 320 kbps 384 kbps Telephone Px64 Network Px56 Network Remote Site Name 8 character Note 1 If p4 is omitted 64 is set Note 2
5. local camera 1 2 control remote camera I 2 control preset number zoom change focus change pan change tilt change diagonally upper direction diagonally lower direction center positive direction negative direction 0 stop moving changing T UP UP P P DP DP Te Response Normal Response OK Error Response ERROI ERR11 ERR12 ERR16 ERR20 ERR27 NDA 24233 Issue 2 Page 3 55 Console Command List VisuaLink 128 384 Engineering Guide 3 21 Option Control Command POCS Pointer Control 21 1 Description Activates or deactivates the on screen pointer The pointer is displayed at the remote monitor This pointer can only be activated when both systems Remote Local are set to a NEC mode Command Format POCS pl p2 p3 pl ON OFF control on off p2 1 99 X axis p3 1 99 Y axis Response Normal Response When Parameter is Omitted pl p2 p3 OK pl ON OFF control on off p2 1 99 X axis p3 1 99 Y axis When Parameter is Specified OK Error Response ERROI ERR36 VCTS Talker Detection Control 21 2 Description Activates or deactivates talker detection When audio is detected the camera will move to a selected preset 1 3 This command is valid only with preset or auto mode camera Command Format VCTIS pl pl ON speaker detection control ON p2 OFF speaker detection control OFF Response Normal Response When Parameter is Omitted plOK pl ON OFF control ON
6. pl OK pl ON report OFF not report When parameter is specified OK Error Response ERROI IMCU Multi point Conference Status Report Control 14 2 Description Activation deactivation of multipoint conference status reporting for things such as COPI CSPI CRPI CVCI CSSC CMPI CJNI CSTI Command Format IMCU pl pl ON report OFF not report Note pl can be omitted If so the current set value is displayed Response Normal Response When parameter is omitted p1 OK pl ON report OFF not report When parameter is specified OK Error Response ERROI NDA 24233 Issue 2 Page 3 43 Console Command List VisuaLink 128 384 Engineering Guide 1243 H 243 Report Control 14 3 Description Activation deactivation of H 243 multipoint conference status reporting for such things as COPI CSPI CRPI CVCI CSSC CMPI CJNI CSTI Command Format 243 pl pl ON report OFF not report Note pl can be omitted If so the current set value is displayed Response Normal Response When parameter is omitted pl OK pl ON report OFF not report When parameter 1s specified OK Error Response ERROI ICGP Command Generator Related Report Control 14 4 Description Activation deactivation of the command generator status reporting for things such as CGSI CGEI Command Format ICGP pl pl ON report OFF not report Note pl can be omitted If so the current set value is displayed Response Norma
7. 2 Description Checks the current video format setting Command Format RVFM Response Normal Response pl OK pl QCIF QCIF FCIF FCIF Error Response ERROI ERRO7 ERR87 Page 3 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SPIP Setting Picture in Picture 1 3 Description Sets PIP small screen display Command Format SPIP pl p2 pl ON PIP output ON OFF PIP output OFF P2 RT Display at top right RB Display at bottom right LT Display at top left LB Display at bottom left Note p2 is omitted when pl Off Response Normal Response OK Error Response ERROI ERRO7 ERR85 ERR87 RPIP Checking Picture in Picture Setting 1 4 Description Checks the current PIP display status Command Format RPIP Response Normal Response p1 p2 OK pl ON PIP output ON OFF PIP output OFF p2 RT Display at top right RB Display at bottom right LT Display at top left LB Display at bottom left Error Response ERROI ERROI ERR87 NDA 24233 Issue 2 Page 3 3 Console Command List VisuaLink 128 384 Engineering Guide SSND Setting Video Input Switch 1 5 Description This sets video input switch Command Format SSND pl p2 pl L local site R remote site p2 Cl Camera 1 C2 Camera 2 Response Normal Response OK Error Response ERROI ERRO7 ERR20 ERR85 ERR87 RSND Checking Video Input Setting 1 6 Description Checks the current video input sendin
8. If p2 Off p3 p4 and p5 are omitted Note 3 If p3 TEL p4 is omitted Normal Response OK Error Response ERRO1 ERROS5 Note If VL128 setting 3B to 6B results in error Page 3 24 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List MDRD Checking Speed Dial Registration 5 4 Description Command Format Response Checks the current registers speed dial number MDRD pl pl xxx Speed dial number xxx speed number Normal Response p1 p2 p3 p4 p5 OK pl xxx speed dial number xxx speed number 1 130 p2 0 9 dial Number within 20 digits sub address within 8 digits i address subaddress Ch1 Ch2 separating code p3 B 64kbps 2B 2x64 kbps 3B 192 kbps 4B 256 kbps 5B 320 kbps 6B 384 kbps TEL Telephone p4 64 Px64 Network 56 Px56 Network p5 xxx Remote Site Name Shift JIS 8 character Note I If pl is omitted all speed dials are displayed Note 2 If non registration only p1 is displayed Note 3 If p3 TEL p4 is omitted Response ERRO1 ERROS NDA 24233 Issue 2 Page 3 25 Console Command List VisuaLink 128 384 Engineering Guide NBZS Setting Incoming Call Buzzer 5 6 Description Sets the incoming call buzzer in a communication using BRI ISDN this sets an incoming call bell to rumble when a request for a incoming call from a remote office is received This setting is valid only when the incoming c
9. Voice Activate Microphone Report PPNI Report Table 35 System Error Command o S e e 5 1 System Error Report ERRI Report I I Table 36 On Screen Display 36 1 Setting On Screen Display SOSD Operation Table 37 Current Power OFF Condition 37 1 Set and read the current Power Off Condition CSTB Status Report Page 2 6 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List Chapter 3 Command Detailed Format Command details are described in this section according to the following format Command Name Command Number Description Describe command features Command Format Describe command input format Response Describe a response to a command NDA 24233 Issue 2 Page 3 1 Console Command List VisuaLink 128 384 Engineering Guide 3 1 VIDEO Commands SVFM Setting Video Format 1 1 Description This sets video format VisuaLink 128 384 is equipped with a feature to code active video with kinds of resolution The formats are QCIF and CIF FICF in parameter based on the ITU T Recommendation H 261 and H 263 Resolution setting affects transmitted video Received video format follows a specification from the transmitting side If FCIF is specified in the remote unit it automatically receives with FCIF resolution Command Format SVFM pl pl QCIF QCIF FCIF FCIF Response Normal Response OK Error Response ERRO1 ERRO7 ERR14 ERR21 ERR87 RVFM Checking Video Format Setting 1
10. a request for connection from a remote unit has been received Command Format NINC pl p2 p3 pl M manual incoming call mode A automatic incoming call mode S selective incoming call mode p2 Remote site number p3 B 64 kbps TEL TEL NONL On line Report 28 3 Description This is an on line report This report to shows the VisuaLink is in communications Command Format NONL pl pl B 64kbps 2B 2x64 kbps 3B 192 kbps 4B 256 kbps 5B 320 kbps 6B 384kbps TERY TEE NDA 24233 Issue 2 Page 3 69 Console Command List NDCI Disconnection Report VisuaLink 128 384 Engineering Guide 28 4 Description Command Format Reports disconnecting the ISDN line This is a report to show that communication is disconnected Section 9 describes the disconnection reason NDCI pl p2 p3 p4 p5 p6 p7 p8 hh mm ss XXXXX 000 999 000 999 000 999 000 999 000 999 000 999 Note If VL128 p5 p8 do not apply communication time hour minute seconds communication fee 0 99 999 Reason for CH1 disconnection Reason for CH2 disconnection Reason for CH3 disconnection Reason for CH4 disconnection Reason for CH5 disconnection Reason for CH6 disconnection Page 3 70 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 29 Camera Control Report Command CAMI Camera Status Report 29 1 Description This is a status report on the remo
11. advance of this disconnection If advance notice is not feasible you will be notified as soon as possible When you are notified you will be given the opportunity to correct the problem and informed of your right to file a complaint with the FCC In the event repairs are ever needed on your Visualink 128 or VisuaLink 384 they should be performed by NEC America Inc or an authorized representative of NEC America Inc For information contact NEC America Inc 1555 W Walnut Hill Lane Irving Texas 75038 3797 USA 972 751 7000 In order to connect this system to the telephone network provide the telephone company with e the quantities and USOC numbers of the required jacks shown below e the sequence in which the trunks are to be connected e the facility interface codes by position and e the ringer equivalence number or service code as applicable by position ee Port USOC Jack REN Service Facility Interface CO Stations Revistration Connector Code Code Ports 5 VisuaLink 128 E E a 021S5 AY5JPN 32617 XD N CSA Requirement To ensure that certified equipment is attached correctly and only to the networks of participating carriers the following statement shall accompany each unit of certified equipment offered for sale This statement must be included conspicuously in written or electronic format at or near the front of each copy of the operating manual or accompany other technical information or be includ
12. the On Screen Message OFF Deactivates the On Screen Message Response Normal Response OK Error Response ERRO1 ERRO7 ERR85 ERR87 Page 3 82 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 37 Current Power OFF Condition CSTB Current Power OFF Condition 37 1 Description Set and read the current Power OFF Condition The CODEC outputs black video when no user intervention has been acted on for a period of time Command Format CSTB pl pl OO 10 up to 10 minutes with one minute intervals CSTB Response Normal Response OK Normal Response 05 OK NDA 24233 Issue 2 Page 3 83 Console Command List VisuaLink 128 384 Engineering Guide This page is for your notes Page 3 84 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Error Response Table 4 Error Response Table If a command input from console is not understandable or has a different configuration an error response is transmitted to the console Error responses are shown in the following table Table 4 1 Error Response Table 1 2 ERR Number Countermeasures accepted by the current system ERRO9 It is a command that cannot be Check current system settings executed in the current mode ERR10 A camera is not connected Check current system settings ERR11 This is not a preset camera Check current system settings ERR12 The displayed screen is not a received Check current system settings video so a remote camera
13. when Snapshot is Viewed 1 10 Description Setting the display image seen in the picture in picture PIP window when a snapshot is viewed Command Format SPSW p1 pl 1 Receiving video 3 Transmitting video Note When pl is omitted the current setting is reported Response Normal Response If pl is set OK If p1 is omitted pl OK pl 1 Receiving video 3 Transmitting video Error Response ERRO1 Page 3 6 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SCPI Setting Checking Video Priority 1 11 The VisuaLink has a function to automatically optimize the picture quality e g number of frames resolution coding noise etc In low bit rate coding there is characteristic for resolution and frame to oppose each other If resolution is imposed the number of frames motion becomes less If however the number of frames increases resolution quality is degraded This requires a trade off Command Format SCPI p1 Description pl R Resolution M Motion Note When pl is omitted the current setting is reported Response Normal Response If p1 is set OK If p1 is omitted p1 OK pl R Resolution M Motion Error Response ERROI S263 Setting H 263 1 12 Description Setting video coding mode to ITU T Recommendation H 263 Command Format S263 pl pl ON H 263 available OFF H 263 not available Response Normal Response OK Error Response ER
14. 24233 Issue 2 VisuaLink 128 384 Engineering Guide RMOD Read Common Mode During Communication Console Command List 7 2 Description Command Format Response Reads negotiated parameter setting RMOD Normal Response p1 p2 p3 p4 p5 p6 p7 p8 OK pl 64 2x64 192 256 320 384 p2 56 64 p3 QCIF FCIF 56 64 kbps 2x56 2x64 kbps 168 192 kbps 224 256 kbps 280 320 kbps 336 384 kbps 56 kbps network p4 ULW SBA LDC OFF ps 4 0 6 4 14 4 24 0 VMLP Off p6 On Off p7 On Off ps8 1 2 4 8 9 6 14 4 OFF Error Response ERRO1 ERRO7 ERR42 ERR46 ERR47 ERR85 ERR87 64 kbps network video format audio mode MLP speed MBE capability T120 capability LSD speed NDA 24233 Issue 2 Page 3 33 Console Command List VisuaLink 128 384 Engineering Guide R221 Read H 221 Synchronous Status 7 3 Description This reads a status of the H 221 frame specified in ITU T Recommendation Command Format R221 Response Normal Response pl OK pl AI frame synchronization established p2 DI frame not in synchronization Error Response ERROI ERRO7 ERR42 ERR46 ERR47 ERR85 ERR87 RPNA Read Remote Site Name at Point to Point 7 4 Description This reads the remote site name in Point to Point P P connection Command Format RPNA Response Normal Response p1 OK pl xx xx alphabet location name within 16 characters Error Response ERRO1 Page 3 34 NDA 24233 Issue 2 Visua
15. CRAM RAST R Table 16 Maintenance and Other Command Command Name Process een Conference Participating Location RMNA Beatie 16 2 Read Multi point Conference Operation Status NEC RMST Status Specific Read Multi point Conference Operation Status RMPS Status Read Multi point Conference Mode Status RMMD NDA 24233 Issue 2 Page 2 3 Chapter 2 VisuaLink 128 384 Engineering Guide Table 17 Model Identification Command Feature Command Name Process 17 1 Read Model Identification RMES Status Table 18 Audio Training Command ooir f Command Name Process 18 1 Initiate Audio Training ECTS Table 19 ISDN Control Command OOo ooo oeme Command Name Process 19 1 Requesting Connection NCRN 19 2 Request Disconnection NDSC 19 3 Incoming Call Permit Reject NCIC 19 4 Communication Status Inquiry NSTQ Table 20 Camera Control Command Oo Feature Command Name Process Request for Camera Direction Change CAMS Table 21 Option Control Command Oo p Fee Command Name Process E Table 22 Multi point Conference Control Oo oo Fee Command Name Request to Chairman Control COPR Multiple Address Transmission Request CSPR Specific Picture Reception Request CRPR Punts to Switch Multiple Address Originator CMPR Table 23 Opening Message Command NOT Feature Command Name Process Opening Message at Unit Activation OMES Page 2 4 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Gui
16. D7 Unused 0 fixed p3 H221 alarm D7 D6 D5 D4 D3 D2 D1 DO DO REC alarm O normal 1 abnormal abnormal D1 CRC alarm O normal 1 D2 7 Unused 0 fixed Page 3 36 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List CALM Read Alarm Status 2 of 2 8 1 Response p4 Bonding alarm D7 D6 D5 D4 D3 D2 D1 DO DO Bonding frame loss 0 normal 1 abnormal D1 Bonding speed negotiation fail 0 normal 1 abnormal D2 Network type negotiation fail 0 normal 1 abnormal 0 0 D3 Dialing number negotiation fail normal 1 abnormal D4 Additional channel connection fail normal 1 abnormal D5 7 Unused 0 fixed p5 TEST status D7 D6 D5 D4 D3 D2 D1 DO DO 3 Unused 0 fixed D4 5 Local Loopback 00 Off 01 Video 10 Audio 11 LINE D6 7 Unused 0 fixed p TEST status 2 D7 D6 D5 D4 D3 D2 D1 DO DO 1 Video mute 0 OFF 1 ON D2 3 Unused 0 Fixed D4 Audio mute 0 OFF 1 ON DS Line 1 loopback 0 OFF 1 ON D6 Line 2 loopback 0 OFF 1 ON D7 Line 3 loopback 0 OFF 1 ON Error Response ERRO1 ERRO7 ERR87 NDA 24233 Issue 2 Page 3 37 Console Command List VisuaLink 128 384 Engineering Guide 3 9 History Reading Command RLAM Read Communication Alarm History 9 1 Description Acquires communication history and alarm history Command Format RLAM pl p2 p3 pl L communica
17. DA 24233 Issue 2 Page 3 53 Console Command List VisuaLink 128 384 Engineering Guide NSTQ Communication Status Inquiry 19 4 Description Command Format Response Note If VL128 p4 p7 are not reported Gives a status on the ISDN communication NSTQ Normal Response p1 p2 p3 p4 p5 p6 p7 OK pl B communication speed B 2B communication speed 2B 3B communication speed 3B 4B communication speed 4B 5B communication speed 5B 6B communication speed 6B TEL communication speed TEL p2 Xx chl communication status see below p3 Xx ch2 communication status see below p4 xx ch3 communication status see below p5 Xx ch4 communication status see below p xx ch5 communication status see below p7 Xx ch6 communication status see below Communication Status xx 01 no communications 02 dialing 03 waiting to connect 04 calling Error Response 05 checking a response 06 communicating 07 disconnecting ERROI ERRO05 ERR41 ERR87 Page 3 54 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide 3 20 Camera Control Command Console Command List CAMS Request for Camera Direction Change 20 1 Description Sets camera head swing control This command is valid only when an preset or auto mode camera is in use A control of Camera 2 is only valid when the camera is the EVI D30 type Command Format CMAS pl p2 pl LI 2 R1 2 p2 1 9 ZX Fx Px Tx UPx DP x H Note x
18. However in parameter error and etc it immediately transmits an error response When an error response is received it analyzes the error contents and suspends the command issuance or reissues a command Page 1 6 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Chapter 1 1 6 Connecting and Incoming Call Control Basic Sequence Connecting and incoming call control basic sequence when the incoming call mode of the VisuaLink receiving a call is set to the manual incoming call setting is shown in the following Console VisuaLink ISDN VisuaLink Console NCRN a Call Origination p Incoming Call seal a OK NINC eR q Connecting pe Connecting am NCIC a NALT lt Connection pe Connection OK E pe NONL NONL m Communicating Disconnect Disconnect NDCI Note I Detailed sequence in a network is omitted in this description Note 2 Parameters of each command is omitted in this description NDA 24233 Issue 2 Page 1 7 Chapter 1 VisuaLink 128 384 Engineering Guide This page is for your notes Page 1 8 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Chapter 2 Chapter 2 Console Command List Table 1 VIDEO Command Command Name NO Feature Process 4 Checka Peuren Piore Seting ae Status 1 12 Setting H 263 S263 Setting Checking H263 Setting R263 Setting Table 2 AUDIO Command 2 1 Setting Audio Mode SAMD Setting Checking Audi
19. LINE alarm p3 00 FF H221 alarm p4 00 FF Bonding alarm p5 00 FF TEST status p6 00 FF TEST status 2 pl CPU VIDEO alarm D7 D6 D5 D4 D3 D2 D1 DO DO CPU alarm 0 normal 1 abnormal D1 FAN alarm 0 normal 1 abnormal D2 3 Unused 0 fixed D4 VIDEO alarm 0 normal 1 input cut D5 7 Unused 0 fixed p2 LINE alarm D7 D6 D5 D4 D3 D2 D1 DO DO 3 Unused 0 fixed D4 SYNC alarm 0 normal 1 abnormal D5 SYNC alarm 0 normal 1 abnormal D6 SYNC alarm 0 normal 1 abnormal D7 Unused 0 fixed p3 H221 alarm D7 D6 D5 D4 D3 D2 D1 DO DO REC alarm 0 normal 1 abnormal D1 CRC alarm 0 normal 1 abnormal D2 7 Unused 0 fixed NDA 24233 Issue 2 Page 3 65 Console Command List VisuaLink 128 384 Engineering Guide RALM Alarm Status Change Report 2 of 2 25 1 p4 Bonding alarm D7 D6 D5 D4 D3 D2 D1 DO DO Bonding frame loss 0 normal 1 abnormal D1 Bonding speed negotiation fail 0 normal 1 abnormal D2 Bonding type negotiation fail 0 normal 1 abnormal D3 Dial number negotiation fail 0 normal 1 abnormal D4 Additional channel connecting error 0 normal 1 abnormal D5 7 Unused 0 fixed ps TEST status D7 D6 D5 D4 D3 D2 D1 DO DO 3 Unused O0 fixed D4 5 Local Loopback 00 01 10 11 D6 7 Unused 0 P6 TEST status 2 D7 D6 D5 D4 D3 D2 D1 DO DO 1 Video mute D2 3 Unused D4 Audio mute D5 Line 1 lo
20. Link 128 384 Engineering Guide RMIC Checking MIC ON OFF Setting 2 6 Description Checks the current microphone setting Command Format RMIC Response Normal Response pl OK pl ON MIC ON OFF MIC OFF Error Response ERROI ERRO7 ERR87 SVOL Setting Volume 2 7 Description Sets adjusts received volume during a communication Command Format SVOL pl pl Volume 0 F 16 stages Volume up Volume down Response Normal Response OK Error Response ERROI ERRO7 ERR85 ERR87 RVOL Checking Volume Setting 2 8 Description Command Format Response Checks the current volume setting RVOL Normal Response Error Response pl OK pl Volume 0 F ERROI ERRO7 ERR87 Page 3 12 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SASW Setting Audio Input Output Port 2 9 Description Sets the audio input port and output port Command Format SASW pl pl LINE LINE HEAD Headset TEL Telephone AUTO Automatic Response Normal Response OK Error Response ERRO1 ERRO7 ERR87 RASW Checking Audio Input Output Port Setting 2 10 Description Checks the current audio input and output setting Command Format RASW Response Normal Response pl OK pl LINE LINE HEAD Headset TEL Telephone AUTO l Automatic Error Response ERROI ERRO7 ERR87 NDA 24233 Issue 2 Page 3 13 Console Command List VisuaLink 128 384 Engineering Guide SMMT Sets Audio or Audio Video
21. Link 128 384 Engineering Guide Console Command List RCST Read Participating Conference Status 7 5 Description This reads conference participating status Command Format RCST Response Normal Response p1 p2 OK pl PP point to point connection MP multi point connection p2 H243 multi point conference based on ITU T H243 MLP NEC specific multi point conference Note When pl PP p2 is omitted Error Response ERROI NDA 24233 Issue 2 Page 3 35 Console Command List VisuaLink 128 384 Engineering Guide 3 8 Alarm Related Command CALM Read Alarm Status 1 of 2 8 1 Acquires alarm status This is used to check the information of a generated alarm and the loopback status Description Command Format CALM Response Normal Response p1 p2 p3 p4 p5 p6 OK pl OO FF CPU VIDEO alarm p2 OO FF LINE alarm p3 OO FF H221 alarm p4 00 FF Bonding alarm p5 00 FF TEST status po OO FF TEST status 2 pl CPU VIDEO alarm D7 D6 D5 D4 D3 D2 D1 DO DO CPU alarm OQ normal 1 abnormal D1 FAN alarm Q normal 1 abnormal D2 3 Unused 0 fixed D4 VIDEO alarm 0 normal 1 input cut D5 7 Unused 0 fixed p2 LINE alarm D7 D6 D5 D4 D3 D2 D1 DO DO 3 Unused 0 fixed D4 Line 1 SYNC alarm 0 normal 1 abnormal D5 Line2 SYNC alarm0O normal 1 abnormal D6 Line3 SYNC alarm0O normal 1 abnormal
22. M G 722 SB ADPCM G 728 LD CELP Mute Audio Byte Rate kbps 56 0 48 0 16 0 Cn a a a Ci SE cannot set A can set but video is not transmitting X snapshot not available 2B 128kbps Line Speed Audio Algorithms G 711 u Law PCM G 722 SB ADPCM G 728 LD CELP Mute Audio Byte Rate kbps 56 0 48 0 16 0 X cannot set NDA 24233 Issue 2 Page B 1 Appendix B VisuaLink 128 384 Engineering Guide This page is for your notes Page B 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Appendix C Appendix C ISDN Q 931 Cause Code Definitions The following table defines the Q 931 cause codes that the VisuaLink 128 384 writes to event files Q 931 specification defines the layer 3 protocol for two connected ISDN devices Table C ISDN Q 931 Cause Code Definitions Unallocated unassigned number aarti seen can not be reached because the number The route to the destination network is not recognized either No route to specified transit network because it does not exist or because it does not serve the equipment sending the message The network through which the call has been routed does not serve No route to destination the desired destination A call is being cleared because the B channel is being preempted for Preemption a call of higher priority If the preempted B channel is not needed for the preempted call it is released for prior use A call is being cleared because the B channel is being preempted for Pr
23. NDA 24233 Issue 2 Page 3 39 Console Command List 3 11 Serial Port Control Command VisuaLink 128 384 Engineering Guide SSIO Setting Serial Port 11 1 Description VisuaLink is equipped with two serial ports and four possible settings T120 data conference Camera control External console control User data Not compliant to T 120 Command Format SSIO pl pl 1 Serial 1 T120 Serial 2 Console 2 Serial 1 Camera Serial 2 Console 3 Serial 1 T120 Serial 2 Camera 4 Serial 1 Console Serial 2 Camera 5 Serial 1 User data Serial 2 Console 6 Serial 1 User data Serial 2 Camera Response Normal Response OK Error Response ERRO1 RSIO Checking Serial Port Setting 11 2 Description Command Format Response Checks the current serial port configuration RSIO Normal Response p1 OK pl NMmBWN Error Response Serial 1 T120 Serial 1 Camera Serial 1 T120 Serial 1 Console Serial 1 User data Serial 1 User data ERRO1 Serial 2 Console Serial 2 Console Serial 2 Camera Serial 2 Camera Serial 2 Console Serial 2 Camera Page 3 40 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 12 Acquiring Version Command RVER Requesting Software Version 12 1 Description Acquires the VisuaLink software version Command Format RVER Response Normal Response p p2 OK pl xXxxxxxxx F W version p2 XxXxxxxxxx DSP version Error Respons
24. NEC NDA 24233 ISSUE 2 STOCK 0293886 VisuaLink 128 384 Engineering Guide JANUARY 1999 NEC Amenica Inc LIABILITY DISCLAIMER NEC America Inc reserves the right to change the specifications functions or features at any time without notice NEC America Inc has prepared this document for use by its em ployees and customers The information contained herein is the property of NEC America Inc and shall not be reproduced without prior written approval from NEC America Inc Copyright 1999 NEC America Inc Printed in USA EXHIBIT J1 FCC REQUIREMENTS NEC America Inc VisuaLink 128 VisuaLink 384 TYPE OF SERVICE The VisuaLink 128 and the VisuaLink 384 are stand alone devices that allow multimedia conferencing by transmitting video audio and data to remote locations over the ISDN Basic Rate interface The VisuaLink 128 and VisuaLink 384 connect to the ISDN digital network through separately registered NTI equipment They provide POTS ports which allow a customer provided 2500 type telephone access to the digital network This equipment complies with Part 68 of the FCC Rules The equipment label will appear on the rear exterior panel of the unit and will provide the FCC Registration Number NEC trade name model number serial number or date of manufacture and the country of origin TELEPHONE COMPANY PROCEDURES The goal of the telephone company is to provide you with the best service it can In order to d
25. O 0 fixed p2 Number of Composite Screen 04 4 screens 09 9 screens 16 16 screens p3 Composite Pattern A fixed Response Normal Response When Parameter is specified OK When Parameter is omitted pl p2 p3 p4 p5 p6 OK pl Composite Screen Status D7 D6 D5 D4 D3 D2 D1 DO D7 D5 D4 D3 D2 D1 D0 p2 Example SXST 00 04 A 01 01 01 02 01 02 03 01 03 OK 0 fixed re lineup 00 none 10 in the order of terminal number speaker display 0 none 1 yes 0 fixed Number of Composite Screen 04 4 screens 09 9 screens 16 16 screens Composite Pattern A fixed Composite Screen Position 01 16 MCU number OO FF Terminal number OO FF Error Response ERROI Page 3 58 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 22 Multi point Conference Control COPR Request to Chairman Control 22 1 Description Acquires or deletes chairman control Command is only valid when the VisuaLink is in a multi point conference Command Format COPR pl p2 pl 1 14 conference room number specified only in a NEC specific multi point conference p2 ON acquire OFF release Note 1 When pl is omitted it becomes a local office conference room number Note 2 pl is omitted in H 243 multi point conference Response Normal Response OK Error Response ERROI ERR20 ERR22 ERR23 ERR24 ERR26 NDA 24233 Issue 2 Page 3 59 Console Comma
26. OFF When Parameter is Specified OK Error Response ERROI Page 3 56 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List STPR SnapShot Transmission Request 21 3 Description Command Format Sends a snapshot still graphic image to the remote site STRP Response Normal Response OK Error Response ERROI SXMR Standard Display Screen Setting Request 21 4 Description Requests for a display setting change when going through the MCU This Command Format Response command is only valid when going through an NEC multi point control unit that has multi screen control capability SXMR pl pl S single screen M multiple composite screen Normal Response When Parameter is Omitted pl OK pl S single screen M multiple composite screen When Parameter is Specified OK Error Response ERROI NDA 24233 Issue 2 Page 3 57 Console Command List VisuaLink 128 384 Engineering Guide SXST Request to Acquire Composite Screen Setting 21 5 Description Request for status on the various video screens displays This command is only valid when going through an NEC multi point control unit MCUSOQ00A that has multi screen control capability Command Format SXST pl p2 p3 pl Composite Screen Status D7 D6 D5 D4 D3 D2 D1 DO D7 D5 0 fixed D4 D3 re lineup OO none 10 in the order of terminal number D2 speaker display 0 none 1 yes D1 D0
27. Outgoing Mute Setting 2 11 Description Sets whether the audio or audio and video outgoing is muted or unmuted at the start of communication when the VisuaLink automatically answers or manual answered calls Command Format SMMT pl pl ON Mute outgoing audio or audio and video at the start of communication OFF Donot Mute audio at the start of communication Default Response Normal Response OK RMMT Checking Audio or Audio VideoOutput Mute Setting 2 12 Description Reads the current MUTED mode setting Command Format RMMT Response Normal Response pl OK pl ON Mute outgoing audio or audio and video at the start of communication OFF Donot Mute audio at the start of communication Page 3 14 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SMTC Sets Audio or Audio Video Mute Setting 2 13 Description Command Format Sets whether the audio or audio and video outgoing is muted or unmuted at the start of communication when the VisuaLink automatically answers or manual answered calls SMTC pl pl A Audio is set to be Muted Default AV Video Audio is set to be Muted Response Normal Response OK RMTC Checking Audio or Audio VideoOutput Mute Setting 2 14 Description Reads what is to be MUTED at the start of communication Command Format Response RMTC Normal Response pl OK pl A Audio is set to be Muted AV Video Audio is set to be Muted NDA 24233 I
28. PNA Read Remote Site Name at Point to Point Ti err re 3 34 RCST Read Participating Conference Status POD ETETA 3 35 PY EED ii e e AE aioli sanieieabnaaiatatciankGurnn T 3 36 CALM Read Alarm Status 1 of 2 G ocninins 3 36 MISON Reading C Om seei E SEEE 3 38 RLAM Read Communication Alarm History 1 inh 3 38 Registering Local Location Name GeOTINVANG caceceiessciravsdnavecsssditsaveacatecmensserrsricerehinitews 3 39 MRNS Registering Local Site Name TOET sceceiderents 3 39 olf cl Mate Oo lide EG oii ealcla s maererenereetr er rere nn Tenn Ceent tren eer nen tatters rn ete eeT etn treat net re 3 40 SSIO Setting Serial Port TROD sehen 3 40 RSIO Checking Serial Port Setting TT Antes 3 40 Aeara ronen 1501 10 4 2 keene eee anemone nie te te eee te A 3 41 RVER Requesting Software Version a gee 3 41 Slice ig aes Uli Ld meee ne eee ee teen ae acne nerN Cer mere en enter ee armen ty thorny aenre maton Meret y 3 42 SLLB Setting Local Loopback f ite 3 42 RLLB Checking Local Loopback Setting 13 2 oo 3 42 Page ii NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Report Response Control Command cccccceeeeecceeeeeaeeeeseeeeeeseaees ITCS Conference Status Report Control IMCU Multi point Conference Status Report Control 1243 H 243 Report Control ICGP Command Generator Related Report Control Maintenance and Other Command c ccccccececcccecececccccecececeeerecens ISPR Setting Parameter Initialization CRAM Cle
29. ROI NDA 24233 Issue 2 Page 3 7 Console Command List VisuaLink 128 384 Engineering Guide R263 Checking H 263 Setting 1 13 Description Reporting the current setting by 263 command Command Format R263 Response Normal Response pl OK pl ON H 263 available OFF H 263 not available Error Response ERROI ERRO7 ERR14 ERR21 ERR87 Page 3 8 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 2 AUDIO Command SAMD Setting Audio Mode 2 1 Description Sets the audio coding format The VisuaLink is capable of u Law PCM SBADPCM and LP CELP Command Format SAMD pl pl OFF OFF ULW G711 u Law PCM 56 kbps SBA G722 SB ADPCM 48 kbps 56 kbps LDC G728 LD CELP 16 kbps Response Normal Response OK Error Response ERROI ERRO7 ERR14 ERR21 ERR87 RAMD Checking Audio Mode Setting 2 2 Description Check current audio mode setting Command Format RAMD Response Normal Response pl OK pl OFF OFF ULW G711 u Law PCM 56 kbps SBA G722 SB ADPCM 48 kbps 56 kbps LDC G728 LD CELP 16 kbps Error Response ERROI ERRO7 ERR87 NDA 24233 Issue 2 Page 3 9 Console Command List VisuaLink 128 384 Engineering Guide SADL Setting Audio Delay 2 3 Description Sets audio delay lip sink Delay is generated when video is coded in transmission and the amount of delay differs depending on a transmission speed On the contrary audio coding del
30. XX OK normal ending EMPTY nodata EX ERR access error CMD ERR command execution error NDA 24233 Issue 2 Page 3 73 Console Command List VisuaLink 128 384 Engineering Guide 3 32 Multi Point Related Report Command IMPS Multi point Conference Operation Status Report 32 1 Description This is a report on the status of multi point conference Command Format IMPS pl p2 p3 p4 p5 p6 pl 1 2255 local site conference room number p2 0 1 status of acquisition of a right to operate in a local site 1 acquired O released p3 1 255 location number of a video transmitting p4 0 1 local site transmitting status 0 OFF 1 ON p5 1 255 a number of multi point conference participants p6 0 1 screen composite capability 0 none 1 yes IMMD Multi point Conference Mode Status Report 32 2 Description This is a report on the status of multi point conference mode Command Format IMMD pl audio switch local site transmission operator reception selection a status of multiple address transmission by operator pl Co COPI Acquisition of Right to Operate Report 32 3 Description This is a report on the acquisition or release of right of chairman mode Command Format COPI pl p2 pl 1 255 conference room number p2 ON OFF acquire release Page 3 74 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List CSPI Multiple Address Transmission Report 32 4 Description Thi
31. all setting is manual Command Format NBZS pl pl ON rng OFF noring Response Normal Response OK Error Response ERROI ERROS5 Note This command is ineffective when setting incoming mode is set to Automatic Utilize this command only in the Manual Answer mode NBZI Checking Incoming Call Buzzer Setting 5 7 Description Checks the current incoming call ring indication setting Command Format NBZI Response Normal Response pl OK pl ON ring OFF noring Response ERRO1 ERROS5 Page 3 26 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SINC Setting Incoming Call Mode 5 8 Description Command Format Response Sets the incoming call mode There are three ways to receive an incoming call manual incoming call mode automatic incoming call mode and selective incoming call mode In a manual incoming call mode an operation to receive a call is required In an automatic incoming call mode a communication starts when a request for an incoming call is received In a selective incoming call mode only those calls that are registered are received All others are rejected SINC pl M manual incoming call mode A automatic incoming call mode S selective incoming call mode pl Note 1 When p1 is omitted the current setting status is displayed in a normal response Note 2 When p1 S an incoming call from the dial number other than those ISDN numbers registered as s
32. aring Backup Memory RRST System Reset Request WCLK Setting System Clock RCLK Checking System Clock Setting Mutli point Conference Status Command cccceececeeeeeeeeeeseeeeeees RMNA Read Multi point Conference Participating Location Name RMST Read Multi point Conference Operation Status NEC Specific RMPS Read Multi point Conference Operation Status RMMD Read Multi point Conference Mode Status Model Identification Command ccecececccecececececececececcaeccacaccavaeass RMES Read Model Identification PU Tanino CGD aser EE ECTS Audio Training Command ISDN Control Command wicoxesecisiassvikevassdesddnnciaesccnecedssanceonienviavsseasssaianens NCRN Requesting Connection NDSC Requesting Disconnection NCIC Incoming Call Permit Reject NSTQ Communication Status Inquiry Camera Control Command ccccccecceccceccsccceccccecscaceccacseacececusuaces CAMS Request for Camera Direction Change Opon Contool Comm tsiciarecaeadepenioesseoneciabotnaeionenenteecoieseesndphierns POCS Pointer Control VCTS Talker Detection Control STPR SnapShot Transmission Request SXMR Standard Display Screen Setting Request SXST Request to Acquire Composite Screen Setting Multi point Conference Control oi ccccavecconceseciccecsacetesavenmatenneaisiereotesseeems COPR Request to Chairman Control CSPR Multiple Address Transmission Request CRPR Specific Picture Reception Request CMPR Request to Switch Multiple Addre
33. ay is about 1 1000 1 100 so a problem that a person s lips and audio cannot be synchronized lip sink VisuaLink is equipped with a feature to insert a delay in audio to compensate lip sink by adjusting a mount of delay Command Format SADL pl p2 p3 pl 64 56 64 kpbs 2x64 2x56 2x64 kbps 3B 168 192 kbps 4B 224 256 kbps 5B 280 320 kbps 6B gt 336 384 kbps p2 000 024 3 digit in decimal fixed 10msec step p3 TX Transmission side Response Normal Response OK Error Response ERROI ERROS5 ERR49 ERR87 Note If VL128 setting 3B to 6B at p1 results in error Page 3 10 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List RADL Checking Audio Mode Setting 2 4 Description Checks the current audio delay setting Command Format RADL pl p2 pl 64 56 64kpbs 2x64 2x56 2x64 kbps 3B 168 192kbps 4B 224 256kbps 5B 280 320kbps 6B gt 336 384kbps p2 TX Transmission side Response Normal Response pl OK pl 000 024 3 digit in decimal fixed 10msec step Error Response ERROI ERROS5 ERR49 ERR87 Note If VL128 setting 3B to 6B at p1 results in error SMIC Setting MIC ON OFF 2 5 Description Sets transmitted audio from a microphone to either ON or OFF Command Format SMIC pl pl ON MICON OFF MIC OFF Response Normal Response OK Error Response ERROI ERRO7 ERR85 ERR87 NDA 24233 Issue 2 Page 3 11 Console Command List Visua
34. cified video reception It is not a specific video reception if it is OO pll O fixed p12 0 fixed p13 0 fixed pl4 O fixed p15 O fixed pl6 O fixed p17 1111 fixed p18 O 1 local site in transmission O not transmitting 1 transmitting Note 1 When pl 0 a local office withdraw from a multi point conference Note 2 Bit assignment of 0000 FFFF is as follows X X 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Master Only Slave Master NDA 24233 Issue 2 Page 3 77 Console Command List VisuaLink 128 384 Engineering Guide 3 33 Multi Screen Related Report Command XMII Composite Screen Setting Report 33 1 Description Reports a composite screen setting Command Format XMII p1 p2 p3 p4 p5 p6 pl Composite Screen Status D7 D6 D5 D4 D3 D2 D1 D0 D7 D5 O fixed D4 D3 _ re lineup 00 none 10 in the order of terminal number D2 speaker display 0 none 1 yes D1 D0 0 fixed p2 Number of Composite Screen 04 4 screens 09 9 screens 16 16 screens p3 Composite Pattern A fixed p4 Composite Screen Position 01 16 p5 MCU number 00 FF p6 Terminal number 00 FF Example XMII 00 04 A 01 01 01 02 01 02 03 01 03 Note p4 p5 p6 is reported only when received from a MCU XMCI Standard Display Screen Setting Report 33 2 Description Reports a standard display screen setting Command Format XMCI pl pl S single screen M malt
35. control cannot be performed ERR16 NEC specific features cannot be Check current system settings performed ERR17 The remote terminal has no capability It is impossible in the current configuration to perform this command ERR18 Cannot be controlled for it is set for a VL is in remote maintenance pass through mode ERR21 Error in data speed setting combination Check current system settings ERR22 The local site is not participating in the Check communication status conference room ERR23 A specified conference room is not Check communication status and execute participating in a multi point command conference ERR26 VL is not in multi point conference Check communication status and execute command ERR32 It cannot be set in the current network Check communication status and execute command ERR37 The remote terminal cannot be Check communication status and execute recognized as a NEC model command ERR20 MLP port has not yet been established Check communication status and execute command again ERR24 Multi point command is either invalid or Check communication status and execute overlapping command ERR38 Local loopback cannot be done since it Execute a command after release of the is processing a remote loopback remote loopback ERR 40 It is in a telephone communication Command to execute is impossible mode ERR41 Network in use is not an ISDN line Check current system settings ERR42 No incoming call Check communica
36. d Normal Response OK Error Response ERRO1 ERR10 Page 3 30 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SCMK Setting Camera Model 6 3 Description Sets types of camera which will be controlled Command Format SCMK pl pl S EVI D30 C VC Cl Response Normal Response OK Error Response ERROI RCMK Checking Camera Model Setting 6 4 Description Checks current camera control setting Command Format Response RCMK Normal Response pl OK pl S EVI D30 C VC Cl Error Response ERROI NDA 24233 Issue 2 Page 3 31 Console Command List 3 7 Communication Status Reading Command RMAC Read Manufacturer Code VisuaLink 128 384 Engineering Guide 7 1 Description Acquires manufacturer code of a remote site Command Format RMAC Response Normal Response p1 p2 p3 p4 p5 OK pl 00 FF Manufacturer code 49 p2 00 FF Division code p3 00 FF Unit code p4 00 FF Own Capability code D7 D6 D5 D4 D3 D2 D1 DO DO Kanji Display Capability D1 Composite Screen Display Capability D2 H281 Camera Control Capability p5 OO FF Error Response Reserved ERROI ERRO7 ERR42 ERR46 ERR47 ERR85 ERR87 NEC other vendor NEC other division of NEC TCS5000EX7 10 MMVC VL128 384 MCUS000A Reserved 0 Off option 1 On option 0 Off 1 On QO Off option 1 On option Page 3 32 NDA
37. d 20 ccceccccceeccceeceeeeeeecaeeceaueceaeececeeeceseeceseueeeseecessaecesaeessaecessaeeesaeeeteneeesaeeeeas 3 19 SDM2 Setting LSD Speed a ere 3 19 RDM2 Checking LSD Speed Setting Oe ntenberaes 3 20 SDM3 Setting MLP Speed i eee oe 3 20 RDM3 Checking MLP Speed Setting 4 4 ooecceeeeees 3 21 ISDN Registering Setting Command cccccssececseececceeeeecceeeeceeeceesaueeeeseusesseaeeessneeeseaaes 3 22 NDSS Registering My Number EN aaa 3 22 NDSR Checking My Number Registration D 2 aaeain 3 23 MDST Registering Speed Dial es anaes 3 24 MDRD Checking Speed Dial Registration OF EET 3 25 NBZS Setting Incoming Call Buzzer Ae ine 3 26 NBZI Checking Incoming Call Buzzer Setting OP sean 3 26 SINC Setting Incoming Call Mode Oe nwnpran 3 27 SRNG Setting Checking Incoming Call Buzzer at Auto Answer Mode 5 9 3 28 SPID Registering SPID Gel epee eee 3 28 RPID Checking SPID PET sarim 3 29 Camera Related Registering Setting Command ccceccccseeeeeteeeeeeeeeeeeeaeeeeeseeeeseaeeeeeees 3 30 CPPS Registering Camera Preset Position BE E 3 30 CPNS Registering Talker Name Bru aaa 3 30 SCMK Setting Camera Model Ao Wiese 3 31 RCMK Checking Camera Model Setting 6 4 ainoana 3 31 Communication Status Reading Command cccceccccceeeecceeeeeeeeeeeeeeeeeeeeaueeeseaeeesseaeeeseas 3 32 RMAC Read Manufacturer Code Fa ETERN 3 32 RMOD Read Common Mode During Communication T sehrini 3 33 R221 Read H 221 Synchronous Status o EENE 3 34 R
38. de Chapter 2 Table 24 Communication Status Report Command NO Feature Command Name Process H 221 Synchronous Status Report H221 Table 25 Alarm Status Report Command NO Feature Command Name Process 25 Table 26 Video Status Report Command Oo Feature Command Name Process 26 1 Incoming Video Synchronous Status Report RVSR Table 27 Participating Status Report Command Oo Feature Command Name Process Participating Conference Status Report ICST Table 28 ISDN Report Command Oo Feature Command Name Process Display During Calling VALT incoming Call Repor NING Orne Report NON Disconnection Repor NDC Table 29 Camera Control Report Command mw Camera Status Report CAMI Report Talker Name Display Report CPNI Report NDA 24233 Issue 2 Page 2 5 Chapter 2 VisuaLink 128 384 Engineering Guide Table 32 Multi point Related Report Command NO Feature CommandName Process Multi point Conference Mode Status Report Report Talker Detection Control Report CVCI SnapShot Transmission Permit Report CSSC oy Address Originator Monitor Video Switch CMPI Terminal Connection Report CJNI 32 10 Conference Status Report CSTI Table 33 Multi Screen Related Report Command NO Feature Command Name Process Composite Screen Setting Report XMII Standard Display Screen Setting Report XMCI R Response to Composite Screen Setting Request XSCI R Table 34 Microphone Command eae N 4 1
39. e lt lt 1 Command 1 is issued using the external control port rather than a personal computer 2 Analysis of a received command parameter error etc is implemented 3 After an analysis if it is normal a normal response is transmitted to a personal computer after transmitting to the remote in communication However if it is error response the error shall be analyzed and a command shall be either suspended or re issued 4 After verifying that Response 1 is normal issue Command 2 Note After issuing a command from a console 1f an alarm emits in VisuaLink an alarm report may be transmitted before a response to the command Abnormal Handshake Procedure When the VisuaLink receives a report command from a remote unit at a time the VisuaLink is sending a command to the remote unit in communication the VisuaLink transmits an indication to a PC using the external control port and then transmits a command to the remote unit Console VisuaLink Remote Command 1 p Report lt Report Command 1 Response 1 sommando NDA 24233 Issue 2 Page 1 5 Chapter 1 VisuaLink 128 384 Engineering Guide 1 Command is issued using the external control port rather than a personal computer 2 Ifa report is received from the remote unit before a transmission of Command 1 it transmits a report to a PC and then transmits Command to the remote unit It transmits Response to the PC after the transmission
40. e ERRO1 ERRO7 ERR87 NDA 24233 Issue 2 Page 3 41 Console Command List VisuaLink 128 384 Engineering Guide 3 13 Maintenance Command SLLB Setting Local Loopback 13 1 Description Command Format Response Sets local loopback process VisuaLink is equipped with a loopback test point inside a terminal for autonomous diagnosis as a maintenance feature Loopback points are as follows AUDIO analog audio section loopback VIDEO analog video section loopback LINE line interface section loopback SLLB pl pl Off release AUDIO audio loopback VIDEO video loopback LINE line loopback Normal Response OK Error Response ERRO1 ERRO7 ERR13 ERR14 ERR38 ERR45 ERR47 ERR87 RLLB Checking Local Loopback Setting 13 2 Description Command Format Response Checks the current loopback status RLLB Normal Response pl OK pl Off release AUDIO audio loopback VIDEO video loopback LINE line loopback Error Response ERROI ERR87 Page 3 42 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 14 Report Response Control Command ITCS Conference Status Report Control 14 1 Description Activation deactivation of conference status reporting for thing such as CAMI CPNI STEI Command Format ITCS pl pl ON report OFF not report Note pl can be omitted If so the current set value is displayed Response Normal Response When parameter is omitted
41. e 1 yes Error Response ERROI RMMD Read Multi point Conference Mode Status 16 4 Description Acquires the multi point conference mode status Command Format RMMD Response Normal Response p1 OK pl 1 audio switch 2 local site video transmission 3 chairman control 4 selective receive 5 a status of multiple address transmission by operator Error Response ERROI NDA 24233 Issue 2 Page 3 49 Console Command List VisuaLink 128 384 Engineering Guide 3 17 Model Identification Command RMES Read Model Identification 17 1 Description Read model identification Command Format RMES Response Normal Response p1 p2 OK pl TC2000_EC VL128 TC2000_6B VL384 p2 F W version ex V01 01 01 Error Response ERROI Page 3 50 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 18 Audio Training Command ECTS Audio Training Command 18 1 Description Initiate audio training White noise is generated while 7 seconds Command Format ECTS Response Normal Response OK Error Response ERROI1 NDA 24233 Issue 2 Page 3 51 Console Command List VisuaLink 128 384 Engineering Guide 3 19 ISDN Control Command NCRN Requesting Connection 19 1 Description Placing a BRI ISDN call A call can be requested by either directly specifying a remote number or using an speed dial number If using an speed dial number it must be registered in advance with MDST command Command Format
42. ed as a separate sheet The required statement is CP 01 Issue 8 Part I Section 14 1 NOTICE The Industry Canada label identifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system 1f present are connected together This precaution may be particularly important in rural areas CAUTION Users should not attempt to make such connections themselves but should contact the ap
43. eece neem rene eter Serene ae tane er aneD nee tente reer nnerst yh nieeer nent rT ett tr Omer 2 5 Table 32 Multi point Related Report Command s seiistesscxssisasianysrarssonionassitedsemmerseraepmnonieaees 2 6 dable ss Mul 5crcen Related Repori Command cniicaccrciiecsraraiisevitecorrrs n EA Aa 2 6 Table 49 Microphone Contant nn cence eee er E ER SEE E REER 2 6 Table 35 System Error Command ssoenessessssssoeeerssssssssserrsssssssscererssssssescreessssssseeeeresssssseeeeees 2 6 De Uian n DPA iora 2 6 Tapie o Corrent Pover OFF LC OnI O tas nna ccnsxcostansssetcsanehaataesneeaaenetcentenaieatsenseentatasasensisants 2 6 dable d i Emor Repone Tae sernai EEE 4 NDA 24233 Issue 2 Page vi VisuaLink 128 384 Engineering Guide Chapter 1 Chapter 1 VisuaLink Command Fundamentals Preface Thank you very much for purchasing the VisuaLink 128 or VisuaLink 384 VisuaLink is suitable for a conference with one to three people on a site and it is a device to realize a multimedia communication of video voice and graphic information by connecting to an ISDN line This document explains the external console of the VisuaLink from a console such as a personal computer NEC Corporation Notes to Remember 1 It is prohibited to copy a part of or the whole of the contents of this document without permission 2 The contents of this document may be modified without notice 3 We did our best in creation of this document however if you notice a
44. eempted circuit reserved for reuse a call of higher priority The B channel is dedicated to the preempted call Normal call clearing A call is being cleared at the request of one of the users No user responding Ae paet o indication was received within the prescribed Connection has not been established in the specified time period No answer from user user alerted and an alert has been received Internal network timers may generate this cause 2 Call rejected ie epi rejected despite the equipment being compatible and The number of the called party is no longer assigned the new number may be reported in the message Cause code 1 is assigned if the network does not support this function A signaling message could not be delivered to the user indicating Destination out of order that the interface to the destination is not functioning correctly Invalid number format address The user cannot be reached because the number is incomplete or in incomplete the wrong format Ea Response to STATUS ENQUIRY A message has been received in response to a STATUS ENQUIRY 31 Normal unspecified A normal event has occurred for which no other cause applies rs Nis fircuiehannebavailable bat appropriate circuit or channel is currently available to handle the at Temporary failure The network is temporarily not functioning correctly Switching equipment congestion The switching equipment is experiencing a period of high tra
45. eport Response Lonirol Command siccrconcienercranveriiarimerameeentmerinwiuans 2 3 Table 15 Manienance and Oiher COMMIT desis cdisrcotecresteisdinsceacelostersiedsectneuestulsdermeloeneii 2 3 Table 16 Maintenance and Other Command ssisisssisiissssisikisosisssisirisiksssnisinis dni ikarinisinsnasintais atni 2 3 Table 17 Model Iidomincanon ON sirsrirrirerieitiditicnis s EE 2 4 Table 18 Audio Training Command enseessssseoeeessssssseserrsssssssscererssssssseceressssssseeeerssssssseeeeeeo 2 4 TDR OE O r curs aero teaniener a eernr unseat convay ret Taenter see 2 4 dant ee EE IC sarran rne IPERE AEN EEEN TANTE RAR 2 4 Tabe ee Ophion Cono C Omm asr E E 2 4 dabie 22 Mut pont Te LONO eroica a 2 4 Table 23 Opening Message Command cccccccccccccssseessecceceeecaaeessecceceeesaeeeseeeeeeseseuaaeesees 2 4 Table 24 Communication Status Report Command ssssssseenessssssseoeersssssssecererssssssseerrrsssssssses 2 5 Jable 253 Alarm Status Keport CT sserssiiiseegsiriedsiniaui anaiai onia nE arn sanaaa 2 5 Tabe 20 Vido BIAS Kopon C onima pestis eerie NE NE EAT 2 5 Table 27 Participating Status Report Command sos seienssnsiveneovesiasseasciornensgiareencemensensiesernicionnenras 2 5 Tate 25 gt WLI Kepo C Omand sssini eniradon Ei a inea 2 5 Table 23 Camera Conirol Report Command sesirikanira a EEEE 2 5 Table 30 Option Control Report Command ccccccccccssssesseeeeceeeeeaeeesssececeeceeaaeeeseeeeeeeeeeeaas 2 5 TPE e a 155 R
46. equested additional service is not Contact a retailer or a service not implemented supported center A connection could Limited digital transmission Contact a retailer or a service LU LN not be made capability among requested center 69 70 transmission capabilities is supported Service or option Report that a service cannot be After checking a remote not implemented provided number retry Invalid call Different dial number from the After checking a remote reference value currently used number is used number retry Please dial again Invalid channel number is used After checking a remote number retry A connection could A different number from the interrupt After checking a remote not be made call discriminating number is used number retry A connection could The interrupt call discriminating After checking a remote not be made number currently in use is used number retry LN LN t num LN LN A connection could Call discriminating number is not After checking a remote RU not be made used number retry A connection could Interrupt call has already been After checking a remote TN LN not be made disconnected number retry Incompatible Attribute of a terminal unit does not After checking a remote LN destination match number retry No available line for Format of a transit network is not After checking a remote use normal number retry 79 81 82 83 84 85 86 88 91 95 96 A c
47. erence room number for a monitor of a simulcast transmission originator Command Format CMPI pl p2 pl 1 255 conference room number of simulcast transmission originator p2 1 255 conference room number to be monitored by simulcast transmission originator Note In pl and p2 indicates screen composition CJNI Terminal Connection Report 32 9 Description This is a terminal connection report Command Format CJNI pl pl 1 255 conference room number of participating terminal Page 3 76 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide CSTI Conference Status Report Console Command List 32 10 Description This is to report the multi point conference status This is reported only in a NEC specific multi point conference Command Format CSTI pl p2 p3 p4 p5 p6 pl 1 14 local site conference number p2 0000 FFFF conference participating status 1 participate 0 not participate p3 0000 FFFF terminal connection status 1 connect 0 not connected p4 0000 FFFF audio switch status 1 switch 0 not switch ps 0000 fixed p6 0000 fixed p7 1 14 operator conference room number 00 no operator p8 1 14 conference room number of the originator of multiple address transmission p9 1 14 conference room number of a location receiving multiple address transmission plo 1 14 conference room number of the originator of a transmission at a spe
48. ffic Number changed NO NO NDA 24233 Issue 2 Page C 1 Appendix C VisuaLink 128 384 Engineering Guide Table C ISDN Q 931 Cause Code Definitions The network could not deliver access information the type of 43 Access information discarded information discarded for example sub address or protocol may be provided in the message ereman ramone Tre capent oss ror somon erence EE requested facility not implemented eee does not support the requested supplemental 70 Only restricted digital information bearer The equipment supports only the restricted version of a service capability is available capability 79 Service or option not implemented The service or option is not implemented and no other cause code unspecified applies 81 Invalid call reference value The call reference value does not match an existing call The requested channel can not be assigned to the call for example Identified channel does not exist channel 13 through 23 have been requested and the user has NO subscribed only to channels 1 through 12 83 A suspended call exists but this call The requested call can not be resumed because it does not identify does not correspond to a suspended call TE The requested call can not be accommodated because of protocol 88 Incompatible destination differences or other incompatibilities such as data rate i E R The call can not be completed because a mandatory information Mandato
49. fied Response Normal Response OK Error Response ERROI ERR20 ERR22 ERR23 ERR24 ERR26 CMPR Request to Switch Multiple Address Originator Monitor 22 4 Description Request to switch the broadcasting video image at the originator s monitor This command is only available when it is in a NEC specific conference mode Command Format CMPR pl pl 1 14 conference room number Response Normal Response OK Error Response ERROI ERR20 ERR22 ERR23 ERR24 ERR26 NDA 24233 Issue 2 Page 3 61 Console Command List VisuaLink 128 384 Engineering Guide 3 23 Opening Control Command OMES Opening Message at Unit Activation 23 1 Description Report opening message at power up This is reported when the unit is automatically re start due to some failure In the case of automatic reset please perform necessary procedures to reconnect the line Command Format OMES pl p2 pl TC2000 EC VL128 TC2000 6B VL384 p2 F W version ex VO1 00 00 Page 3 62 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide 3 24 Communication Status Report Command Console Command List H221 H 221 Synchronous Status Report 24 1 Description H 221 reporting status change Command Format H221 pl pl Al synchronization established DI out of synchronization IMAC Manufacturer Code Report 24 2 Description Reports a manufacturer code for the remote site Command Format IMAC pl p2 p3 p4 p5 OK
50. g status Command Format RSND pl pl L local site R remote site Response Normal Response pl OK pl Cl Camera 1 C2 Camera 2 Error Response ERROI ERRO7 ERR20 ERR87 Page 3 4 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List SDSP Setting Monitor Output Video 1 7 Description Sets output video image Command Format SDSP pl pl TX Transmission Video RX Reception Video STL Still picture Response Normal Response OK Error Response ERROI ERRO7 ERR85 ERR87 Note User will be unable to switch to STILL PICTURE if STILL PICTURE graphics has not been sent RDSP Checking Monitor Output Video Setting 1 8 Description Checks the current video output setting Command Format RDSP Response Normal Response pl OK pl TX Transmission Video RX Reception Video STL Still picture Error Response ERROI ERRO7 ERR87 NDA 24233 Issue 2 Page 3 5 Console Command List VisuaLink 128 384 Engineering Guide SPDP Setting Checking PIP Display Format 1 9 Description Setting the display image seen in the picture in picture PIP window Command Format SPDP p1 pl M miror image is displayed N non mirror image is displayed Note When pl is omitted the current setting is reported Response Normal Response If pl is set OK If p1 is omitted pl OK pl M mirror display N non mirror display Error Response ERRO1 SPSW Setting Checking PIP Image
51. gital basic leased lines are currently only available in Japan NNSI Checking Transmission Line Type Setting 3 4 Description Checks the current line interface setting Command Format NNSI Response Normal Response pl OK pl D2B High speed digital basic leased line 128k Interface I2B National ISDN 1 Basic Interface Rate Error Response ERROI ERROS5 ERRO7 ERR87 NDA 24233 Issue 2 Page 3 17 Console Command List VisuaLink 128 384 Engineering Guide SLSP Setting Transmission Line Speed 3 5 Description Sets transmission speed Command Format SLSP pl pl B 56 64 kbps 2B 2x56 2x64 kbps 3B 168 192 kbps 4B 224 256 kbps 5B 280 320 kbps 6B 336 384 kbps Response Normal Response OK Error Response ERROI ERROS5 ERRO7 ERR21 ERR45 ERR87 Note If VL128 setting 3B to 6B results in error RLSP Checking Transmission Line Speed Setting 3 6 Description Checks the current transmission speed setting Command Format RSLP Response Normal Response pl OK pl 64 56 64 kbps 2x64 2x56 2x64 kbps 192 168 192 kbps 256 224 256 kbps 320 280 320 kbps 384 336 384 kbps Error Response ERROI ERRO7 ERR87 Note The response will always be a 64 kbps increment It is recommended that the RNET command be used combined with RLSP Page 3 18 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide 3 4 DATA Command SDM2 Setting LSD Speed Console Command List 4 1 Descr
52. ilure Line layer 1 failure Physical Contact a retailer or a service connection error center 904 Network failure Line layer 2 failure Electric Contact a retailer or a service interface error center 905 Network failure or TEI error Contact a retailer or a service wrong contact center 906 Network failure Layer 3 Appreciation layer calling Contact a retailer or a service timed out center 907 Disconnected by Not used initialization 908 Disconnected by Not used Contact a retailer or a service initialization center 909 Disconnected by Not used Contact a retailer or a service initialization center 912 Disconnected by Message inconsistent with the After a while retry initialization current condition is received 913 Disconnected by Connect and disconnect during are After a while retry initialization start response waiting 914 Network failure Lower layer in failure 915 network failure Lower layer in failure 916 The provisioned Calling condition is NG communication time expired 917 A connection could Layer 3 initialization not completed not be made 918 A connection could Layer 3 initialization missed not be made 919 A connection could CES pointing error not be made 980 VCP Video chip hang up After a while retry NDA 24233 Issue 2 Page 5 3 Factors of Disconnections This page is for your notes Page 5 4 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Appendix A Append
53. iple composite screen Page 3 78 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List XSCI Response to Composite Screen Setting Request 33 3 Description This is a response report of composite screen setting acquisition request Command Format XSCI pl pl OK normal ERRxx NG NDA 24233 Issue 2 Page 3 79 Console Command List VisuaLink 128 384 Engineering Guide 3 34 Microphone Command PPNI Voice Activate Microphone Report 34 1 Description Report microphone that inputs the voice Command Format PPNI pl pl l to 3 Page 3 80 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 35 System Error Command ERRI System Error Report 35 1 Description Report system error Command Format ERRI pl pl S_RAM BACKUP ERROR SRAM error SYSTEM BACKUP ERROR System parameter error M_DIAL BACKUP ERROR Speed dial information error S_ NAME BACKUP ERROR Preset talker name error C_PRIS BACKUP ERROR VC C1 preset error CG FILE BACKUP ERROR CG file error S_PRIS BACKUP ERROR EVI D30 preset error R_ DIAL BACKUP ERROR Redial information error AEC_7K INITIAL ERROR Echo canceller initialize failure NDA 24233 Issue 2 Page 3 81 Console Command List VisuaLink 128 384 Engineering Guide 3 36 On Screen Command SOSD Setting On Screen Display 36 1 Description Sets the On Screen displays for the VisuaLink Command Format SOSD pl pl ON Activates
54. iption Command Format Response Setting Low Speed Data LSD port speed e Allows for H 281 far end camera control e PC to PC data transmission SDM2 pl pl OFF 12 4 8 6 4 9 6 Normal Response Error Response 14 4 OFF 1 2 kbps 4 8 kbps 6 4 kbps 9 6 kbps 14 4 kbps ERRO1 ERROS ERRO7 ERR21 ERR87 NDA 24233 Issue 2 Page 3 19 Console Command List VisuaLink 128 384 Engineering Guide RDM2 Checking LSD Speed Setting 4 2 Description Reporting the current LSD speed by SDM2 command Command Format RDM2 Response Normal Response pl OK pl OFF OFF l2 i 1 2 kbps 4 8 4 8kbps 6 4 6 4 kbps 9 6 9 6 kbps 14 4 14 4 kbps Error Response ERROI ERROS5 ERRO7 ERR21 ERR87 SDM3 Setting MLP Speed 4 3 Description Sets the Multi Layer Protocol MLP data port speed e Allows for NEC far end camera and system control e Allows for T 120 transmission Command Format SDM3 pl pl OFF OFF 40 4 0 kbps 6 4 6 4kbps 14 4 14 4 kbps 24 0 24 0 kbps Response Normal Response OK Error Response ERROI ERROS5 ERRO7 ERR21 ERR87 Page 3 20 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List RDM3 Checking MLP Speed Setting 4 4 Description Checks the current MLP speed setting Command Format RDM3 Response Normal Response pl OK pl OFF OFF 40 4 0 kbps 6 4 6 4kbps 14 4 14 4 kbps 24 0 24 0 kbps Error Response ERROI
55. it Line Field OAH Report Format Command Name Space Parameter CR LF Command Transmit 4 character reports Command only upper case can be used Space More than one space is transmitted between a command and a parameter Parameter If a command requires a parameter a parameter is assigned Only upper case can be used However if parameters are more than one more than one space is transmitted between parameters CR Transmit Carriage Return Code ODH LF Transmit Line Field OAH Page 1 4 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Chapter 1 1 5 Communication Procedure There is no procedure for communication between a console and VisuaLink as a rule Therefore a communication line is presumed to be error free When it is remotely operated with a modem efficient Operation may not be expected when a line error occurs Because of this in a remote control a modem with error correction feature shall be used or VisuaLink shall be checked for operation Command Response Procedure VisuaLink transmits a confirmation on whether a command is received and the process is completed After sending a command please always analyze the transmitted response before issuing a next command If the next command is issued before a response an error response such as currently processing may be returned PC Console VisuaLink Command 1 os Response Command 2 p p Respons
56. ix A Pin out Specification Pin out specifications for all the VL 128 384 connectors To 4 8 6 5 3 2 1 8 PIN MIN DIN FEMALE SERIAL 1 PORT Note The signal direction shown is seen from the VisuaLink 128 DTE SERIAL 2 PORT Request to Send al Clear to Send 8 6 7 IN l OUT OUT Data Terminal Read y 8 PIN MIN DIN FEMALE IN Data set Ready Note The signal direction shown is seen from the VisuaLink 128 DTE RING Headset TIP Name Function A l O SLEEVE HEADSET JACK MIC Connection 1 3 RING Name Funcion Polarity TIP Input from microphone x i SLEEVE MIC JACK RING Output to ear piece pe SLEEVE Ground NDA 24233 Issue 2 Page A 1 Appendix A VisuaLink 128 384 Engineering Guide S T Line ISDN Connection Symbol Function Polarity 9 ReceiveTip e Receive Ring ate ame ea CTransmitRing Note I The signal direction shown is seen from the VisuaLink 128 DTE Note 2 Pins 1 2 7 and 8 are not used RJ45 FEMALE Telephone Connection RJ11 FEMALE SOCKET B Output S Video Socket Input Output Analog GND Analog GND Y Signal I O Signal IN Analog GND Y Signal OUT AG AG AG Analog GND AG O Signal OUT SOCKET A Input Page A 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Appendix B Appendix B Line Speed Specifications 1B 64kbps Line Speed Audio Algorithms G 711 u Law PC
57. l Response When parameter is omitted pl OK pl ON report OFF not report When parameter is specified OK Error Response ERROI Page 3 44 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 15 Maintenance and Other Command ISPR Setting Parameter Initialization 15 1 Description Initializes all VisuaLink values to factory default Command Format ISPR Response Normal Response OK Error Response ERRO1 CRAM Clearing Backup Memory 15 2 Description Initializes registered data Command Format CRAM pl pl T abbreviated speed dial registration S camera preset registration Note If not specified both registered contents are initialized Response Normal Response OK Error Response ERROI RRST System Reset Request 15 3 Description Resets the VisuaLink Command Format RRST Response Normal Response OK Error Response ERRO1 NDA 24233 Issue 2 Page 3 45 Console Command List VisuaLink 128 384 Engineering Guide WCLK Setting System Clock 15 4 Description Sets the VisuaLink built in system clock date and time Command Format WCLK pl p2 p3 p4 p5 p6 p7 pl yyyy year p2 01 12 month p3 01 31 date p4 01 24 hour p5 00 59 minute po 00 59 second p7 XXX day of the week MON TUE WED THU FRI SAT SUN Response Normal Response OK Error Response ERROI RCLK Checking System Clock Setting 15 5 Description Reads the VisuaLink bui
58. l connection status 1 connect 0 not connected audio switch status 1 switch 0 not switch fixed fixed operator conference room number 00 no operator conference room number of the originator of multiple address transmission conference room number of a location receiving multiple address transmission conference room number of the originator of a transmission at a specify video reception Itis not a specific video reception if it is 00 fixed fixed fixed fixed fixed fixed fixed local office in transmission O not transmitting 1 transmitting When p1 0 a local site withdraw from a multi point conference Bit assignment of 0000 FFFF is as follows XIX Master Only 12 11101 9 817161514 131211 Master Page 3 48 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List RMPS Read Multi point Conference Operation Status 16 3 Description Acquires the multi point conference status Command Format RMPS Response Normal Response p1 p2 p3 p4 p5 p6 OK pl 1 255 local site conference room number p2 0 1 status of acquisition of a right to operate in a local site 1 acquired O released p3 1 255 location number of a video being received p4 0 1 local site video transmitting status 0 OFF 1 ON p5 1 255 a number of multi point conference participants p6 0 1 screen composite capability 0 non
59. lt in system clock date and time Command Format RCLK Response Normal Response p1 p2 p3 p4 p5 p6 p7 OK pl yyyy year p2 01 12 month p3 01 31 date p4 01 24 hour p5 00 59 minute po 00 59 second p7 XXX day of the week MON TUE WED THU FRI SAT SUN Error Response ERROI1 Page 3 46 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 16 Mutli point Conference Status Command RMNA Read Multi point Conference Participating Location Name 16 1 Description Command Format Response Acquires location name of all location participating locations in multi point conference RMNA pl pl 1 255 conference room number can be specified in multiple Normal Response p1 p2 p3 OK pl 1 999 conference room number p2 XXXXXXXX location name in alphabet p3 XXXXXXXX location name in Japanese character Error Response ERRO1 ERR24 NDA 24233 Issue 2 Page 3 47 Console Command List VisuaLink 128 384 Engineering Guide RMST Read Multi point Conference Operation Status NEC Specific 16 2 Description Acquires a status of a multi point conference status when in activated for NEC specific multi point conference Command Format RMST p1 p2 p3 p4 p5 p6 pl p2 1 14 0000 FFFF QOOO FFFF 0000 FFFF 0000 0000 1 14 O OO OS OS local site conference number conference participating status 1 participate 0 not participate termina
60. mand Format Command Name Space Parameter CR LF Command Transmit 4 character commands only upper case can be used Space More than one space is transmitted between a command and a parameter Parameter If a command requires a parameter a parameter is assigned Only upper case can be used However if parameters are more than one more than one space is transmitted between parameters CR Transmit Carriage Return Code ODH LF Transmit Line Field OAH Response Format When the VisuaLink 128 384 is provisioned and controlled with a console VisuaLink 128 384 always sends a response Responses are normal response and error response When sending a command from a console please transmit the next command after checking a response A response is transmitted in the following format Normal Ending Response Parameter when required OK CR LF Parameter If a command is inquiring a provisioned value a response parameter is returned If there is no parameter it 1s omitted However if parameters are more than one more than one space is transmitted between parameters Space More than one space is transmitted between a command and a parameter CR Transmit Carriage Rerun Code ODH LF Transmit Line Field OAH Error Ending ERRxx CR LF ERRxx Three character ERR and a 2 digit error number are transmitted indicating a failure CR Transmit Carriage Return Code ODH LF Transm
61. mat a 3 6 SPSW Setting Checking PIP Image when Snapshot is Viewed TE senian 3 6 SCPI Setting Checking Video Priority 1 11 we 3 7 S263 Setting H 263 TU ecru 3 7 R263 Checking H 263 Setting oe ee 3 8 pO aes iirc 8 ener nate ener men tonne ete en tray rene O 3 9 SAMD Setting Audio Mode Ol EEES 3 9 RAMD Checking Audio Mode Setting 2 2 hivintiintcnenin 3 9 SADL Setting Audio Delay AF cee 3 10 RADL Checking Audio Mode Setting On eeceeseeeeeees 3 11 SMIC Setting MIC ON OFF T ET 3 11 RMIC Checking MIC ON OFF Setting D coronas 3 12 SVOL Setting Volume E aaen 3 12 RVOL Checking Volume Setting CAO EN 3 12 SASW Setting Audio Input Output Port E ceapisiieteen 3 13 RASW Checking Audio Input Output Port Setting 2A E 3 13 SMMT Sets Audio or Audio Video Outgoing Mute Setting PAT Giese 3 14 RMMT Checking Audio or Audio VideoOutput Mute Setting 2 12 e 3 14 SMTC Sets Audio or Audio Video Mute Setting 2 13 wo 3 15 RMTC Checking Audio or Audio VideoOutput Mute Setting OPA E 3 15 Ma l a E i EEEE PN ate neee arrestee ere enemaees 3 16 SNET Setting Network Type P x 64 56 DAI pereon 3 16 RNET Checking Network Type Setting P x 64 56 e EE 3 16 NNSS Setting Transmission Line Type a a EA 3 17 NNSI Checking Transmission Line Type Setting S ET 3 17 SLSP Setting Transmission Line Speed 3 5 ieatieceinneies 3 18 RLSP Checking Transmission Line Speed Setting UD aois 3 18 NDA 24233 Issue 2 Page i Table of Contents VisuaLink 128 384 Engineering Guide DATA Comman
62. n off and on again ice i Negotiation between switch and CODEC has failed Power the unit 908 Disconnected by initialization off and on again 912 Disconnected by initialization Software processing other task Power the unit off and on again 913 Disconnected by initialization Software processing other task Power the unit off and on again Lower layer negation has failed Try again If problem continues 314 Network failure contact your carrier Lower layer negation has failed Try again If problem continues 319 Network failure contact your carrier 916 E Communica von UMET Call condition is No Good Please check number and try again 917 Running Network Initialize Procedure an 3 initialization has not completed Wait a few minutes and try 918 Incorrect registered SPID numbers Check SPID registration CES pointing error Wait a few seconds and try again If problem 919 Aconnection could not be made continues contact your carrier 980 VCE Video Chip has hung up Reset the unit and try again NDA 24233 Issue 2 Page C 3 Appendix C VisuaLink 128 384 Engineering Guide This page is for your notes Page C 4 NDA 24233 Issue 2
63. nd List VisuaLink 128 384 Engineering Guide CSPR Multiple Address Transmission Request 22 2 Description Command Format Response Acquires the simulcast transmission CSPR pl pl 0 255 conference room number to be received composite screen display Note I When pl is omitted it becomes a local office conference room number Also in a NEC specific multi point conference 1 14 only can be specified Note 2 Inpl is valid only when a MCU to connect has a capability of screen composition Note 3 In pl 0 is valid in H 243 multi point conference It means a release of simulcast transmission Normal Response OK Error Response ERROI ERR20 ERR22 ERR23 ERR24 ERR26 Page 3 60 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List CRPR Specific Picture Reception Request 22 3 Description Activates or deactivates selective receive mode Command Format CRPR pl p2 p3 pl 1 255 reception side conference room number p2 1 255 transmission side conference room number F composite screen display p3 ON reception selection setting release OFF reception selection release Note 1 When pl is omitted it becomes a local office conference room number Note 2 pl is omitted in H 243 multi point conference Note 3 In p2 is valid only when a MCU to connect has a capability of screen composition Also in a NEC specific multi point conference 1 14 only can be speci
64. ne3 Channel L32 Line3 Channel2 Response Note If VL128 setting L21 L32 in pl are not valid and will create an error Normal Response Error Response pl p2 OK pl L11 Linel Channell L12 Linel Channel2 L21 Line2 Channell L Line2 Channel2 L31 Line3 Channel L32 Line3 Channel2 p2 SPID ERRO1 NDA 24233 Issue 2 Page 3 29 Console Command List VisuaLink 128 384 Engineering Guide 3 6 Camera Related Registering Setting Command CPPS Registering Camera Preset Position 6 1 Description Command Format Registers a camera preset position CPPS pl p2 p3 p4 pl Ll 2 Local Camera Number R1 2 Remote Camera Number p2 1 9 Preset Number p3 ON Register OFF Release p4 x x Talker Registration alphabet 16 character Note 1 When p3 is OFF p4 is omitted Note 2 A talker name is deleted in p4 Response Normal Response p1 OK Response ERR01 ERR10 CPNS Registering Talker Name 6 2 Description Registers a preset talker name Command Format Response CPNS pl p2 p3 pl Ll 2 Local Camera Number p2 1 9 Talker Name Number p3 x x Talker Name Registration alphabet 16 character Note 1 When p2 is OFF the contents of registration of a talker name number is displayed Note 2 A talker name is deleted in p2 Note 3 When p1 and p2 are omitted all the registered contents are displayed When a talker name is not registered No Entry is displaye
65. ny problems errors and omissions please let us know 4 We are not responsible for the result of any operation of the device regardless of the above note 5 Please prepare countermeasures such as recovery and backup for possible failures on a system side when you use this device in a system in which a superior reliability is expected 1 1 Summary VisuaLink is equipped with a serial external control port that enables a control from a console such as a personal computer The VisuaLink executes a command and returns a response based on the inputting of a command that consist of 4 characters or one character and three numbers 1 2 Communication Outline Communication protocol between the VisuaLink and a console are consisted of the following 1 Command A protocol issued by a console executes a process on VisuaLink 2 Response A protocol that issues a result for a command to a console It is always issued at a command reception Responses are normal ending response and error response 3 Report When a status is changed inside VisuaLink a change notice such as an alarm is issued to a console Message protocol is issued independently from a command NDA 24233 Issue 2 Page 1 1 Chapter 1 VisuaLink 128 384 Engineering Guide 1 3 Physical Electrical Interface The external control port is at the back of the VisuaLink and uses DIN8 pin connectors The maximum length of the control cable shall be no more than 20 ft 6 1 meter d
66. o Mode Setting RAMD Status Setting Audio Delay SADL Setting Checking Audio Delay Setting RADL Status Seting MIC OON SWIC Checking MIC On Off Setting RMIC Status Seting Volume SVOL Checking Volume Setting RVOL Status Setting Audio Input Output Port SASW Checking Audio Input Output Port Setting RASW D11 Setting Audio Mute Operation at start of SMMT Setting Communications 9 12 Reads the current Mute mode setting at start of RMMT Status Communications 9 13 Sets the Audio and Audio Video Mute mode at start SMTC Satin of Communications 9 14 Reads the current Mute control at start of RMTC Status Communications Table 3 LINE Setting Command Command Name Setting Network Type P x 64 56 SNET Setting Checking Network Type Setting P x 64 56 RNET Status Ses oo Seting Transmission Line Type NDA 24233 Issue 2 Page 2 1 Chapter 2 VisuaLink 128 384 Engineering Guide Table 4 DATA Command Command Name Seting Checking LSD Speed Setting Status Setting MLP Speed SDV Checking MLP Speed Setting RDM3 Table 5 ISDN Registering Setting Command Oo ooo oeme O Command Name Process i Registering My Number NSS Sng Checking My Number Registration sa Redisterng Speed Dial e Y Sting ee Checking Speed Dial Registration 5 6 Seting incoming CalBuzzer NBZS Sting Checking Incoming Call Buzzer Setting NBZI Status 58 o Setting Incoming Call Mode SINC Setting Status Setting Checking Incoming Call Buzzer at Aut
67. o SRNG Setting Status Answer Mode 510 Registering SPID SPID Checking SPID mo oo Status Table 6 Camera related Registering Setting Command Oo p Feaue CommandName Process Table 7 Communication Status Reading Command Omo o Fee Command Name Process Read Manufacturer Code RMAC Read Common Mode During Communication RMOD Read H 221 Synchronous Status R221 7 4 Read Remote Site Name at Point to Point RPNA tatus Read Participating Conference Status RCST Status Table 8 Alarm related Command o Feature CommandName 8 1 Read Alarm Status CALM Status Table 9 History Reading Command ee ee Name _ 9 1 Read Communication Alarm History RLAM Status Page 2 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Chapter 2 Table 10 Registering Local Location Name Command NO Feature CommandName Process 10 1 Registering Local Site Name MRNS Setting Table 11 Serial Port Control Command NO Feature CommandName Process Seting Serial Pori SSI0 Checking Serial Port Setting RSIO Table 12 Acquiring Version Command NO Feature Command Namie Process Requesting Software Version RVER Table 13 Maintenance Command NO Feature CommandName Process Seting Local Loopback SILE Checking Local Loopback Setting RLLB Table 14 Report Response Control Command Omo Foe CommandName Process Table 15 Maintenance and Other Command NOT Fee Command Name SPR
68. o this it may occasionally be necessary for them to make changes in their equipment operations or procedures If these changes might affect your service or the operation of your equipment the telephone company will give you notice in writing to allow you to make any changes necessary to maintain uninterrupted service If you have any questions about your telephone line such as how many pieces of equipment you can connect to it the telephone company will give you notice in writing to allow you to make any changes necessary to maintain uninterrupted service In certain circumstances it may be necessary for the telephone company to request from you concerning the equipment which you have connected to your telephone line Upon request of the telephone company provide the FCC registration number and the ringer equivalence number REN of the equipment which is connected to your line both of these items are listed on the equipment label The sum of all of the REN s on your telephone lines should be less than five in order to assure proper service from the telephone company In some cases a sum of five may not be usable on a given line IF PROBLEMS ARISE If any of your telephone equipment is not operating properly you should immediately remove it from your telephone lines as it may cause harm to the telephone network If the telephone company notes a problem they may temporarily discontinue service When practical they will notify you in
69. onnection could Report of other invalid messages not be made Mandatory Required information element is in Contact a retailer or a service LU LN information element short center is missing A connection could Undefined or not provided message Contact a retailer or a service LU LN not be made is received center A connection could Message mismatch Contact a retailer or a service LU LN not be made center A connection could Information element is undefined Contact a retailer or a service LU LN not be made center 100 Invalid information The contents of information element Contact a retailer or a service LU LN element contents is invalid center 101 Message not Received message and a call status After checking a remote LU LN compatible with call mismatch number retry state 102 Recovery on timer Restoration due to an expiration of After checking a remote LU LN expiry timer number retry Page 5 2 NDA 24233 Issue 2 97 98 99 VisuaLink 128 384 Engineering Guide Factors of Disconnections Number Message Factors for Disconnection Countermeasure Example 111 Protocol error Report of other protocol error After checking a remote unspecified number retry 127 Interworking Inter work occurrence in a network After checking a remote unspecified that cannot display a reason for number retry operation 901 No response from Automatic Dial timed out Check a remote unit status the remote terminal 903 Network fa
70. opback D6 Line 2 loopback D7 Line 3 loopback Off Video Audio LINE fixed 0 normal 0 fixed 0 normal 0 OFF 0 OFF 0 OFF p pi ee abnormal abnormal ON ON ON Page 3 66 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 26 Video Status Report Command RVSR Incoming Video Synchronous Status Report 26 1 Description VisuaLink monitors a synchronization status of a received video and a report is made when a received video synchronization status changes Command Format RVSR pl pl Al synchronization established DI out of synchronization NDA 24233 Issue 2 Page 3 67 Console Command List VisuaLink 128 384 Engineering Guide 3 27 Participating Status Report Command ICST Participating Conference Status Report 27 1 Description Reports participating conference status Command Format ICST pl p2 pl PP point point connection MP multipoint connection p2 H243 multi point conference based on ITU T H243 MLP NEC specific multi point conference Note When p1 PP p2 is omitted Page 3 68 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 28 ISDN Report Command NALT Display During Calling 28 1 Description Call report status an origination point This means calling to remote site Command Format NALT NINC Incoming Call Report 28 2 Description Incoming call report This is a report to indicate
71. ork Remote is busy Connected channel is used channel is used After a while After a while retry connection connection Normal is busy Bate e restoration of a disconnection of a he again call is requested User busy It is currently in a communication After a while make a RU RN with others connection again 18 No user response user response No response response Check status of remote unit status of remote unit 19 a alerting no EC rE response after a call message is Bianchina status of remote unit answer received Call rejected Communication is rejected Check status of remote unit 22 Aes terminal number has been Check remote number make a 26 Non selected user No incoming bell After a while aie clearing 27 a out of Remote terminal is P ener veneer status of remote unit RU a 28 Invalid number a format or incomplete Danana remote number and AA format address number retry incomplete alll Facility rejected Requested facility is not allowed bisa remote number LRU Response to Inquiry for status was received aetna remote number and LU LN STATus ENquiry retry 31 Normal Normal status was reported After a while retry unspecified Circuit channel No line or channel is available Check communication status LN RN TN pongeston 38 Network is not functioning normally After a while retry a 41 a Temporary failure Network is temporarily not available After a
72. peed dial numbers Normal Response If p1 is set OK If p1 is omitted pl OK M manual incoming call mode A automatic incoming call mode S selective incoming call mode pl Error Response ERRO1 ERRO05 NDA 24233 Issue 2 Page 3 27 Console Command List VisuaLink 128 384 Engineering Guide SRNG Setting Checking Incoming Call Buzzer at Auto Answer Mode 5 9 Description Setting ringing times of incoming call buzzer in auto answer mode or selective answer mode Command Format SRNG pl pl 0 9 0 not ringing 1 9 ringing times Note When pl is omitted the current setting is reported Response Normal Response If pl is set OK If p1 is omitted pl OK pl 0 not ringing 1 9 ringing times Error Response ERROI SPID Registering SPID 5 10 Description Setting Service Profile ID SPID Command Format SPID pl p2 pl Lil Linel Channell L12 Linel Channel2 L21 Line2 Channell L22 Line2 Channel2 L31 Line3 Channell L32 Line3 Channel2 p2 SPID 0 9 up to 20 digits OFF Delete Response Normal Response OK Error Response ERROI Note If VL128 setting L21 L32 in pl are not valid and will create an error Page 3 28 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide RPID Console Command List Checking SPID 5 11 Description Reporting current SPID Command Format RPID pl pl Lil Linel Channell L12 Linel Channel2 L21 Line2 Channel L22 Line2 Channel2 L31 Li
73. propriate electric inspection MODEL CERTIFICATE NUMBER CERTIFICATION NUMBER VisuaLink 128 19318 140 9004A VisuaLink 384 19603 140 9104A VisuaLink 128 384 Engineering Guide Table of Contents Table of Contents Chapter 1 VisuaLink Command Fundamentals ccesseceeseeeeeeeeeeeenseesees 1 1 BITS AEE A EET E EAE ease mare teneeny A EAS 1 1 CEMAT i E iE E Ei 1 1 Physical eI II sirsiran ana EA EEE eel 1 2 Ca a FOE erriren EEEN EAE EEE EEE ER 1 3 Communication Procedure cceecccceeccceeceeceeeceeeceeeuceeseeceeseeeeseeessaceeseeeessueessusesseeeesaeeeesaes 1 5 Connecting and Incoming Call Control Basic Sequence cccceecccseeeeceeeeceeeeseeeeeseeeessees 1 7 Chapter 2 Console Command List ssccceseeseeeceeseeeeenseeeeeseeeseesseesenneessonneesees 2 1 Chapter 3 Command Detailed Format scseeeesssesseeeseeesseeeeeeessseeseeenseeessneeaes 3 1 VIDEO Commands ccc eecccsecccceeceeceececeeeeeceececeuceeseeeceeeeeseneesseeeeseueessaeeessneesseeeseeeesaneessaes 3 2 SVFM Setting Video Format Pi Gann 3 2 RVFM Checking Video Format Setting T a 3 2 SPIP Setting Picture in Picture e TEE 3 3 RPIP Checking Picture in Picture Setting Tl etienienens 3 3 SSND Setting Video Input Switch Fo sue 3 4 RSND Checking Video Input Setting E E EEEN 3 4 SDSP Setting Monitor Output Video 1 jac 3 5 RDSP Checking Monitor Output Video Setting 190 EEEE 3 5 SPDP Setting Checking PIP Display For
74. ry information element is missing element is missing 97 Message type non existent or not The received message is not a recognized message type implemented Message not compatible with call state or The message can not be received while in the call state message type non existent or not implemented ids Information received could not be processed because of incorrectly 100 Invalid information element contents coded elements 101 Message not compatible with call state The message received is not compatible with the call state 102 Recovery on time expiry A recovery procedure has been initiated after the prescribed time l The message was triggered by internetworking with a network that 127 Interworking unspecified does not provide ice pee J Page C 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Appendix C Table C ISDN Q 931 Cause Code Definitions 901 No response from the remote terminal Automatic dialer has timed out Please check number and try again 903 Network failure Layer 1 failure Verify physical network connection Layer 2 failure Verify the pin out between the CODEC and the 908 Networstalllre network termination device is correct 905 Network Failure or wrong contact TEl error If failure continues contact your carrier Network Contact Layer 3 caller timer timed out Try again sken di saag Negotiation between switch and CODEC has failed Power the unit 907 Disconnected by initializatio
75. s is to report the completion of a simulcast transmission Command Format CSPI pl pl 0 255 conference room number Note 1 When pl 0 it indicates a release of a multiple address transmission in H 243 multi point conference Note 2 When pl it indicates a screen composition CRPI Specific Picture Reception Report 32 5 Description This report on a completion of specific video reception process Command Format CRPI pl p2 p3 pl 1 255 reception side conference room number p2 1 255 transmission side conference room number p3 ON OFF reception selection setting release Note 1 In a NEC specific multi point conference 1 14 only can be specified Note 2 In p2 indicates a screen composition CVCI Talker Detection Control Report 32 6 Description This report the execution of an audio switch process Command Format CVCI pl p2 p1 0 255 audio switch control conference room number p2 ON OFF audio switch execution release Note When p1 0 it indicates a general setting NDA 24233 Issue 2 Page 3 75 Console Command List VisuaLink 128 384 Engineering Guide CSSC SnapShot Transmission Permit Report 32 7 Description This report is a request to transmit a snapshot Command Format CSSC pl pl 1 255 conference room number where a still picture transmission request was made CMPI Multiple Address Originator Monitor Video Switch Report 32 8 Description This report a conf
76. seeeeeeneeeneeees 5 1 Appendix A Pin out Specification cccccccccssseeecesseeccenseeeeenseeseessessonseeseenneessones A 1 Appendix B Line Speed Specifications cccccssseseeesseseeeeeeeseeseesseeseeeseeesensseesenass B 1 Appendix C ISDN Q 931 Cause Code Definitions ccccccesssssssseeeeeeeeeessnseeeees C 1 NDA 24233 Issue 2 Page v VisuaLink 128 384 Engineering Guide List of Tables List of Tables gis Ml bee Go Ge Gor arr Wan rtry brit soon Pern tT PeOnrTerT rs nny ee rarer Tety 2 1 Doke AUDRI COMI eee eenenne te reser TET trees te tr satel terete rr vse erie errr er eer rrr er 2 1 UPN MR a O are EREIN EE AAEE TNTA 2 1 DBEST DAAE O oa E 2 2 Table 5 ISDN Regsistering Setting Command siisesisrirsssricsinrrsssakareiiriinraiaratr isinaka 2 2 Table 6 Camera related Registering Setting Command ccccccesseesseeceeceeeceeeeseeeceeeeeeeaas 2 2 Table 7 Communication Status Reading Command icescntsreceiaiieinarearacdalannuademnomselieiaaeacccns 2 2 Tae Anminan eiriaa a Aea r R EAS 2 2 Tabes Fistory Kendis Comman sarsripritrrinar riar EE EA E E ATAN 2 2 Table 10 Registering Local Location Name Command ssesssooenesssssssseeeressssssseeeresssssssseeeeee 2 3 Table 11 Serial Port Control Command esseesseeoeenssssssssserrrssssssssserrsssssssseeressssssssseeeesssssssees 2 3 Labe Lo An Varron a serr 2 3 Tape a COMMON ahr caceces ccesetmgp tacit uneis innen EERE r OER NANESTE 2 3 Table 14 R
77. snnonnnnennnnnnnnnsenensnrnnnnneerrreesnreerreee IMPS Multi point Conference Operation Status Report IMMD Multi point Conference Mode Status Report COPI Acquisition of Right to Operate Report CSPI Multiple Address Transmission Report CRPI Specific Picture Reception Report CVCI Talker Detection Control Report CSSC SnapShot Transmission Permit Report CMPI Multiple Address Originator Monitor Video Switch Report CJNI Terminal Connection Report CSTI Conference Status Report Multi Screen Related Report Command ccccececseeeeceeeeceeeeeceneesseeeeses XMII Composite Screen Setting Report XMCI Standard Display Screen Setting Report XSCI Response to Composite Screen Setting Request Kro P One COmnmMaA N aaepe E E PPNI Voice Activate Microphone Report CR Error COMMA stateside ErskErsr tsr eE KSs EN TARTINE SS Erir S rs eii ERRI System Error Report On Screen Command cccccecececcccccecececccccccececececeacauaeaeaeeaeavaceeseesersnenens SOSD Setting On Screen Display Current Power OFF Condition ccccccccecececececececececcceccccaeacacececenensneness CSTB Current Power OFF Condition VisuaLink 128 384 Engineering Guide Page iv NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Table of Contents Chapter 4 Error Response Table ccccesseeccesseeceenseeecesseeseesseesensseeeeenseesenseees 4 1 Chapter 5 List of Factors for Disconnection in Table ccccsssseessse
78. ss Originator Monitor Opening Control Command esse tics cecsensics ereslidceie deiaceceseareeerdsperemes OMES Opening Message at Unit Activation Communication Status Report Command ccccceecceeeeeeceeeeeeeeeeeees H221 H 221 Synchronous Status Report IMAC Manufacturer Code Report IMOD Report of Common Mode in Communication Table of Contents NDA 24233 Issue 2 Page iii Table of Contents Alarm Status Report Command cccccceeccceeeeeeceeeeeeeeeeeesaeeeeeeaeeeeseeeeesens RALM Alarm Status Change Report 1 of 2 RALM Alarm Status Change Report 2 of 2 Video Status Report Command aetna eee eee ean cea ae eee ee RVSR Incoming Video Synchronous Status Report Participating Status Report Command cccccecsececeeececeeeeseeseeseeeesseeeess ICST Participating Conference Status Report Fe sinini AEn Aane NA NALT Display During Calling NINC Incoming Call Report NONL On line Report NDCI Disconnection Report Camera Control Report Command sicsssicninnritetisdarivenrtcecdasteneditastiaccnceese nines CAMI Camera Status Report CPNI Talker Name Display Report Op on Control Report Command secientet resbecinepesuteersieewsdirenetceseneaeweadeensi STEI SnapShot Transmission Ending Report RFVR SnapShot Reception Report Oter Fanon LOMMEN siais engaia ni SDi CGSI Automatic Activation File Starting Report CGEI Automatic Activating File Ending Report Multi Point Related Report Command s sas
79. ssue 2 Page 3 15 Console Command List VisuaLink 128 384 Engineering Guide 3 3 LINE Setting Command SNET Setting Network Type P x 64 56 3 1 Description Sets a network type P x 64 56 Some networks use 8 kbps out of the 64 kbps for network control information so the network available for users may be limited to P x 56 kbps When connecting to the network check if it is a limited network P x 56 or clear network P x 64 Command Format SNET pl pl Px64 Clear Network Type Px56 Limited Network Type Response Normal Response OK Error Response ERROI ERROS5 ERRO7 ERR21 ERR45 ERR87 Note The command can only be issued when the VisuaLink is not in a call RNET Checking Network Type Setting P x 64 56 3 2 Description Checks the current network setting P x 64 56 Command Format RNET Response Normal Response pl OK pl Px64 Unlimited network Px56 Limited network Error Response ERROI ERRO7 ERR87 Page 3 16 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List NNSS Setting Transmission Line Type 3 3 Description Sets the line interface High speed digital basic leased line 128k I Interface or National ISDN 1 Basic Rate Interface Command Format NNSS pl pl D2B High speed digital basic leased line 128k I Interface 2B National ISDN 1 Basic Interface Rate Response Normal Response OK Error Response ERROI ERROS ERRO7 ERR87 Note High Speed di
80. te camera condition When remote camera control is used Command Format CAMI pl pl 0 not connected 1 fixed camera J preset camera CPNI Talker Name Display Report 29 2 Description This is a report on a conference room number of a remote camera and a preset talker name Command Format CPNI pl p2 pl 0 99 conference room number p2 XXxxx preset talker name alphabet 16 character NDA 24233 Issue 2 Page 3 71 Console Command List VisuaLink 128 384 Engineering Guide 3 30 Option Control Report Command STEI SnapShot Transmission Ending Report 30 1 Description This is a report notifying a snapshot transmission is completed Command Format STEI pl pl OK normal ending NG failure RFVR SnapShot Reception Report 30 2 Description This is a report when receiving a snapshot picture Command Format RFVR pl pl 01 receiving 00 receiving is completed Page 3 72 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 31 Other Report Command CGSI Automatic Activation File Starting Report 31 1 Description This is a report to show the start of auto executed file Command Format CGSI pl pl 0 7 number of file for auto executed file CGEI Automatic Activating File Ending Report 31 2 Description This is a report to show the completion of auto executed file Command Format CGEI p1 p2 pl 0 7 number of file for auto executed file p2 Xxxxx ending result XX
81. tion history A alarm history p2 yyyy mm dd hh mm starting date p3 yyyy mm dd hh mm ending date yyyy year mm month dd date hh hour mm minute Note p2 and p3 can be omitted If so all the histories are output Response Normal Response p1 p2 OK pl yyyy mm ddhh mm date p2 XXXXXXXXXX contents of history xx is moved to a new line after 50 byte Error Response ERROI Example 1 Communication history RLAM L 1997 10 20 09 46 NALT 1997 10 20 09 47 NONL 2B 1997 10 20 09 57 NDCI 00 10 00 110 016 016 OK Example 2 Alarm history RLAM A 1997 10 20 09 35 RALM 10 00 00 00 00 00 1997 10 20 09 37 RLAM 00 00 01 00 00 00 1997 10 20 09 38 RLAM 00 00 00 00 00 00 OK Page 3 38 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Console Command List 3 10 Registering Local Location Name Command MRNS Registering Local Site Name 10 1 Description Command Format Response Registers a local site location name MRNS pl p2 pl Xxxxxxxx alphabet location name within 16 characters p2 XXXXXXXX character location name within 16 characters Note I When pl is omitted a location name is deleted Note 2 When p1 is omitted p2 is omitted Normal Response when parameter is specified OK when parameter is omitted p1 p2 OK pl Xxxxxxxx alphabet location name within 16 characters p2 XXXXXXXX character location name within 16 characters Error Response ERROI
82. tion status and execute command ERR43 Currently originating a call Check communication status and execute command ERR44 Incoming call Check communication status and execute command ERR45 On line Check communication status and execute command again NDA 24233 Issue 2 Page 4 1 Error Response Table VisuaLink 128 384 Engineering Guide Figure 4 1 Error Response Table 2 2 ERR Number ERR46 Off line Check communication status and execute command again ERR48 Disconnecting Check communication status and execute command again ERR49 Specified delay time is not in decimal Check the format of command step generator Is In execution Execution is impossible Re start VL unit Page 4 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Factors of Disconnections 5 List of Factors for Disconnection in Table Location of Factors for Disconnection LU Local User LN Local Network TN Transit Network RU Remote User RN Remote Network Number Message Factors for Disconnection Countermeasure Example 1 Unassigned Call cannot come in since it is Check the remote number LN RU number currently a unassigned number 2 No route to Specified transit network cannot be Check the remote number TN LN specified transit recognized network 3 No route to No route to remote site Check the remote number LN RU destination 6 Cancel A channel cannot be accepted in a After a while retry connection ar roe netw
83. ue to electric characteristics Connector pin positions are as follows No Name Direction Features 2 Serao afew Sanat Groun s fo WN Reeve p p o sf e os N aasia Note Directions of signals are output from VisuaLink Page 1 2 NDA 24233 Issue 2 VisuaLink 128 384 Engineering Guide Chapter 1 1 4 Communication Format Communication between a console and VisuaLink 128 384 is done in a start stop synchronization of the following format Data Format START AS CII 8bit PTY STOP 1 2 3 4 5 6 7 8 9 Data Length 7 8 bit ASCII code Stop Bit 1 bit Parity Even Odd NONE parity Baud 1200 2400 4800 9600bps Note Default setting for VisuaLink is 9600 8 none 1 To change the default setting use the SSPR command A Connect terminal to VisuaLink Serial 2 B Set terminal application to Baud 9600 Parity Even Bit 8 Stopbit 1 C Calculate the Baud Parity and Bit by be bs by bz by bi bo Not in use Not in use 00 1200bps 01 2400bps 10 4800bps 11 9600bps 00 7 bit EVEN I STOP 01 1 7 bit IODD STOP 10 8 bit EVEN STOP 11 8 bit NONE I STOP D Set system parameter command for the appropriate setting Example SSPR 168 21 Means Your VL in now set up for 2400 8 EVEN 1 E Reset the VL NDA 24233 Issue 2 Page 1 3 Chapter 1 VisuaLink 128 384 Engineering Guide Com
84. while Afterawhile retry a Switching Switch is busy a a while retry equipment oro Access information Requested information element After a while nr discarded cannot be transmitted to a remote as channel Reported line or channel cannot be ee a while retry a not available provided Resource oo status that other network is Contact a retailer or a service unavailable busy center unspecified 49 This service is QOS cannot be provided RU RN currently not LN available NDA 24233 Issue 2 Page 5 1 Factors of Disconnections Requested facility Procedure for a requested facility is Contact a retailer or a service not subscribed not taken center Bearer capability Unauthorized transmission Contact a retailer or a service not authorized capability was requested center Bearer capability Transmission capability currently Contact a retailer or a service not presently not available for use center available Service or option Report that other services cannot be Contact a retailer or a service not available used center Number Message Factors for Disconnection Countermeasure Example 50 57 58 Bearer capability Requested transmission capability Contact a retailer or a service not implemented is not supported center LN LN LN 63 LN 65 66 N This service is Requested channel class is not Contact a retailer or a service RU RN currently not supported center L available Requested facility R
Download Pdf Manuals
Related Search
Related Contents
Important Safety Instructions Instrucciones de seguridad importantes Enduit de réparation Cortadora láser instrucciones AUTOCAD THE ACPD TECHNIQUE : Copyright © All rights reserved.
Failed to retrieve file