Home
Mustang Survival MD3075 Life Jacket User Manual
Contents
1. MUSTANG SURVIVAL MD3075 Inflatable PFD Manual Inflation Model Recreational USCG Approved Type III INFLATABLE PERSONAL FLOTATION DEVICE DO NOT REMOVE PRIOR TO SALE CONTENTS Page 1 Approval Conditions and Carriage Regulations 1 Mandatory Carriage Requirements 1 What is an Inflatable PFD 2 Instructions for Use 2 Component Inspection Instructions 2 Readiness Checklist 3 Sizing and Fit 3 Donning Instructions 4 Inflating Your Inflatable PFD 5 Deflating the Inflatable PFD 6 Usage Below Freezing 6 Re arming Your PFD MD3075 8 Repacking 9 Is Your PFD in Good and Servicable Condition 9 Care and Maintenance Instructions 11 Cleaning and Storing of Your Inflatable PFD MD3075 11 Why are PFDs Required Safety Equipment 12 How and Why to Test Your PFD 12 How Do You Test Your PFD Using the Manual Inflator 13 How Do You Test Your PFD Using the Oral Inflator 14 Wear Your PFD 14 Hypothermia 15 Each of These Devices is Intended to Help You Save Your Own Life 16 Inflatable PFD Safety Accessories 16 Additional Information Inflatable PFD Owner s Manual i APPROVAL CONDITIONS AND CARRIAGE REQUIREMENTS This Inflatable PFD is approved by the U S Coast Guard USCG for use as a Type III Model MD3075 Personal Flotation Device PFD It is not approved for water skiing or other high impact high speed activities This Inflatable PFD was designed to be more comfortable and less restrictive to wear than inherently buoyant PFDs Whe
2. PFD Remove the dust cap from the end of the oral tube and blow into the tube until the Inflatable PFD is fully inflated Place the oral inflator dust cap back in the stowed position Fig 6 WARNING Avoid double inflation CO cylinder inflation after full oral inflation as it could damage the PFD FIGURE 4 E Deflating the Inflatable PFD To deflate the Inflatable PFD reverse the oral inflation tube dust cap and insert it into the valve or depress valve with fingertip The dust cap will not lock in the deflate position so it is necessary to hold it in place Fig 5 Gently squeeze the Inflatable PFD until all air or gas has been expelled To avoid damage do not wring or twist the Inflatable PFD Put the inflation tube dust cap back in its stowed position on the oral inflation tube Fig 6 Examine the service indicator Fig 1 If the service indicator is red the mechanism has been fired or is incorrectly fitted and the inflator requires service see Re arming your PFD MD3075 NOTE The service indicator must be green before proceeding Your device is ready to be repacked see Repacking p 8 Inflatable PFD Owner s Manual FIGURE 5 FIGURE 6 Oral Inflator a n Dust cap Dust cap Boios in stowed position for position deflation Y Usage Below Freezing When the temperature is below freezing the Inflatable PFD should be worn partially inflated because a fully discha
3. PFD so you know what to do in an emergency 11 Inflatable PFD Owner s Manual HOW AND WHY TO TEST YOUR PFD Inflate your Inflatable PFD and try it out in the water to Make sure it floats you e Comfortably when worn properly e Adequately for expected wave conditions body shapes densities affect performance Make sure it works e A flow of bubbles should not appear see CARE AND MAINTENANCE INSTRUCTIONS for leak tests p 9 It should inflate quick and easily Learn how it works by e Activating the CO3 inflation system e Re arming the CO3 inflation system e Using the oral inflator tube The U S Coast Guard recommends that you purchase two rearming kits One to be used immediately in testing the inflation system see HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR and the other to carry onboard as a spare To check the manual inflation system with CO cylinder bayonet assembly removed determine that the CO cylinder piercing pin moves freely when pushing up on the lever arm by pushing down on the pins and releasing the pins followed by the lever arm Repeat this several times to check the manual inflation system HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR 1 To test your Inflatable PFD you will need your fully armed Inflatable PFD and re arming kit approved for your Inflatable PFD MA7203 2 Put on the Inflatable PFD 3 Actuate the inflation system by jerking firmly downward on the pull tab The Inflatabl
4. still strong All Velcro and waist belt are securely fastened Inflatable PFD is not twisted Oral inflation dust cap is in the stowed position Fig 6 Jerk to inflate tab exits bottom of pouch Your Inflatable PFD is ready for use if all applicable boxes are checked NOTE Contact your Mustang Dealer if you have any concerns about the readiness of your Inflatable PFD Sizing and Fit This PFD provides a minimum of 33 7 lbs of buoyancy when inflated and is designed for wearers over 16 years of age with a chest range of 30 52 inches 76 132 cm weighing over 80 pounds 36 kg Donning Instructions It is important that the Inflatable PFD is properly adjusted to fit the person wearing it An incorrect fit or improper fastening of attachments could impede its effectiveness 1 All belts and straps are already threaded correctly and only need to be adjusted for fit The MD3075 waist belt should fit securely below your rib cage 2 Put the Inflatable PFD on just like a standard waist belt pack and fasten the front buckle Adjust waist belt to a snug comfortable fit and secure the belt s loose end in the belt loop Do not wear Inflatable PFD under clothing as the inflation could be restricted or you could be injured Fig 2 Step 1 and 2 WARNING Do not wear Inflatable PFDs under clothing as the inflation could be restricted or you could be injured FIGURE 2 3 In
5. 16 50 60 1 2 hrs 1 6 hrs 16 21 60 70 2 7 hrs 2 40 hrs 21 27 70 80 2 12 hrs 3 hrs to Indefinite over 27 over 80 Indefinite Indefinite PFDs can increase survival time because they allow you to float without using energy treading water and because of their insulating properties Naturally the warmer the water the less insulation you will require When operating in cold waters below 60 F 15 6 C you should consider using a coat or jacket style PFD or a Type V Thermal Protective PFD as they cover more of the body than the vest or belt style PFDs Some Points to Remember About Hypothermia Protection 1 Always wear your Inflatable PFD Even if you become incapacitated due to hypothermia the Inflatable PFD will keep you afloat and greatly improve your chances of rescue Inflatable PFD Owner s Manual 14 Do not attempt to swim unless it is to reach a nearby craft fellow survivor or a floating object on which you can lean or climb Swimming increases the rate of body heat loss In cold water drown proofing methods that require putting your head in the water are not recommended Keep your head out of the water This will greatly lessen heat loss and increase your survival time Use the standard H E L P position when wearing an Inflatable PFD drawing the legs up to a seated position because doing so will help you conserve body heat Fig 10 Keep a positive attitude about your survival and rescue This will improve your c
6. IMD3075 Manual Inflator Tab SS Ooh Piercing Pin Ces Lever 5 Examine the service indicator Fig 8 and ensure it is GREEN If the service indicator is red the mechanism has been fired or is incorrectly fitted and the inflator requires service See Re arming Your PFD MD3075 p 6 NOTE The service indicator must be green before proceeding 7 Inflatable PFD Owner s Manual 6 Refold the Inflatable PFD in accordance with the Repacking section p 9 YOUR INFLATABLE PFD MD3075 IS NOW READY FOR MANUAL USE Repacking Gently squeeze the Inflatable PFD until all air or gas has been expelled Fig 5 Do not wring or twist the Inflatable PFD Put the oral tube dust cap back in its stowed position on the oral inflation tube Fig 6 NOTE Before following the repacking sequence be sure to properly re arm your Inflatable PFD 1 Lay the bladder and pouch out on a flat surface with the bladder s inflator and oral tube facing the flat surface Fig 9 2 Fold sides to meet in the middle 3 Start by folding bladder at first crease roughly 2 from bottom Continue folding the bladder using the creases as guidance FIGURE 9 Push in cap to deflate Bladder must be completely deflated before starting Lay flat on surface with CO2 cylinder and oral tube facing down FOLD Do not Roll Tuck fold
7. e PFD should fully inflate within 5 seconds 4 Get into shallow water just deep enough that you can stand with your head above the surface 5 See if the Inflatable PFD will float you on your back or just slightly Inflatable PFD Owner s Manual 12 7 back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs and how you float Get out of the water and remove the Inflatable PFD Completely deflate the Inflatable PFD using the oral inflator see Deflating the Inflatable PFD p 5 Remove the CO cylinder bayonet assembly from the inflator Let the Inflatable PFD dry thoroughly Re arm amp Repack the PFD p 6 HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR 1 13 No spare parts or re arming kits are needed to test your Inflatable PFD Remove the CO cylinder bayonet assembly to prevent inadvertent inflation which could potentially damage the Inflatable PFD Inspect the cylinder to confirm it is unused Fig 7 Put on the Inflatable PFD Get into shallow water just deep enough that you can stand with your head above the surface If you are a weak swimmer or non swimmer orally inflate the Inflatable PFD partially so that you are supported well enough to be able to complete inflation without touching bottom Note this level of inflation because it is the minimum needed for you to safely use this Inflatable PFD Fully in
8. ed bladder into pouch and close bottom __ 6 JERK TO INFLATE TAB MUST EXIT THE BOTTOM OF THE OPENING MAKE SURE GREEN INDICATOR IS VISIBLE THROUGH WIDOW Inflatable PFD Owner s Manual 8 4 Without twisting fold the bladder over once and place into the centre of the pouch between the two wings Fig 9 Ensure the yellow inflator pulltab is positioned so it hangs out from the bottom between the Velcro closure 5 Position so that green indicator is visible through window 6 Ensure yellow pulltab is still hanging out the bottom of the pouch 7 Close Velcro at bottom of pouch IS YOUR PFD IN GOOD AND SERVICEABLE CONDITION Check your Inflatable PFD between outings to be sure that it is properly armed that it is free of rips tears or holes that all seams are securely sewn and that the fabric straps and hardware are still strong See Readiness Checklist p 2 Inspect the inflatable portion of the Inflatable PFD in accordance with the CARE AND MAINTENANCE INSTRUCTIONS CARE AND MAINTENANCE INSTRUCTIONS Federal Regulations require Coast Guard approved personal flotation devices PFDs that are legibly marked with the Coast Guard approval number are in good and serviceable condition and are the correct size for each person on board It is the responsibility of the operator to be sure this PFD is in serviceable condition To be considered serviceable this PFD shall not exhibit deteriora
9. flatable PFD Owner s Manual Deployment and Use of the PFD Fig2 Step 3 6 Inflating then donning 1 Either pull out the bladder from fabric casing then inflate orally or pull sharply on tab to inflate 2 Put over head 3 Tie the tie tapes at neckline Donning then inflating 1 Pull out the bladder 2 Put over head 3 Pull sharply on tab to inflate or inflate orally 4 Tie the tie tapes at neckline Inflating Your Inflatable PFD It is recommended that the following procedures be followed to inflate your Inflatable PFD 1 Manual Inflation Activate the inflation system by jerking firmly downward on the pull tab Fig 3 The Inflatable PFD should fully inflate within 5 seconds FIGURE 3 Permeation Loss Information When inflated the carbon dioxide CO gas used to inflate the PFD will slowly escape through the fabric over time A slight reduction of pressure will be observed after several hours of inflation Topping up by oral inflation may be required in the event of very prolonged immersion 2 Oral Inflation Properly armed and inspected Inflatable PFDs will inflate when manually or automatically activated However you can fully inflate Inflatable PFD Owner s Manual 4 the Inflatable PFD by mouth Fig 4 should inflation not occur or if you are in a non emergency situation To orally inflate the Inflatable PFD first locate the oral inflation tube by opening the cover panel of the Inflatable
10. flate the Inflatable PFD using the oral tube See if the Inflatable PFD will float you on your back or just slightly back of vertical In a relaxed floating position verify that your mouth is well above the water s surface Note the effect of where you hold your legs on how you float Get out of the water and remove the Inflatable PFD Completely deflate the Inflatable PFD using the oral tube Let the Inflatable PFD dry thoroughly Re arm and repack the PFD p 6 Inflatable PFD Owner s Manual WEAR YOUR PFD In approximately 80 percent of all boating fatalities the victims were not wearing a PFD Most fatal accidents happen on calm sunny days This Inflatable PFD is much more comfortable to wear than other PFD types Get into the habit of wearing this Inflatable PFD Non swimmers and children especially should wear a hybrid or non Inflatable PFD at all times when on or near the water HYPOTHERMIA Prolonged exposure to cold water causes a condition known as hypothermia a substantial loss of body heat which leads to exhaustion and unconsciousness Most drowning victims first suffer from hypothermia The following chart shows the effects of hypothermia how hypothermia affects most adults How hypothermia affects most adults Water Exhaustion or Expected Temperature C F Unconsciousness Time of Survival 0 3 32 5 Under 15 min Under 15 45 min 0 3 4 32 5 40 15 30 min 30 90 min 4 10 40 50 30 60 min 1 3 hrs 10
11. hances of extending your survival time until rescued Your will to live does make a difference If there is more than one person in the water huddling is recommended while waiting to be rescued This action tends to reduce the rate of heat loss and thus increase the survival time FIGURE 10 Zl HELP Position EACH OF THESE DEVICES IS INTENDED TO HELP YOU SAVE YOUR OWN LIFE For your Inflatable PFD to function properly follow these suggestions to verify that it fits floats and remains in good condition 1 Check the inflation mechanism status indicators before each use 2 Get in the habit of re arming the inflation mechanism right after 15 each inflation Inflatable PFD Owner s Manual 3 Try your wearable Inflatable PFD on and adjust it until it fits comfortably in and out of the water 4 Mark your Inflatable PFD with your name if you are the only wearer 5 Do not alter your Inflatable PFD If it doesn t fit properly get one that does An altered device is no longer Coast Guard approved 6 Your Inflatable PFD is not intended for use as a fender or kneeling pad 7 If your Inflatable PFD is wet allow it to dry thoroughly before storing it Store it in a well ventilated area 8 Do not dry your Inflatable PFD in front of a radiator or other source of direct heat Inflatable PFD Safety Accessories For the MD3075 MA7203 Re arm Kit Contains 33 gram replacement CO cylinder bayonet assembly fo
12. horse design is a registered trademark of Mustang Survival Corp Our commitment to quality has earned our Burnaby facilities ISO 9001 registration the highest of all international standards This is our guarantee you re receiving the ultimate in design and manufacturing HT 3075 Rev 10Aug2011
13. lve Test To check the oral inflation valve fully inflate the Inflatable PFD using the oral inflator and hold valve under water If bubbles appear deflate and re inflate to test again Should the leak persist take your Inflatable PFD to your Mustang dealer for evaluation and or servicing iii Perform a thorough visual examination See Readiness Checklist p 2 Perform these tests more often if exposed to potential damage or used in extreme conditions After Each Inflation Re arm the Inflatable PFD See Re arming Your PFD p 6 Annually Perform the following at the beginning of each boating season after inflation or whenever the integrity of the Inflatable PFD is in doubt i Check all components for dirt or corrosion Clean or replace as neccessary See Readiness Checklist p 2 ii Visually examine your Inflatable PFD for damage or excessive abrasion wear tear or contamination Particular attention must be paid to the stitching straps and hardware If in doubt send it to your Mustang dealer for evaluation and or servicing iii Perform the Oral Inflation Valve Test See the Oral Inflation Valve Test in the Every Two 2 Months Care and Maintenance Instructions section Inflatable PFD Owner s Manual 10 iv Perform the Leak Test See the Leak Test in the Every Two 2 Months Care and Maintenance Instructions section v Ensure the service indicator is green Fig 1 vi Record as an Annual inspection in per
14. manent ink on the Care and Storage label in the Date Maintained column Repack the Inflatable PFD as outlined in the Repacking section p 8 WARNING If you are not confident in the self inspection and servicing of your Inflatable PFD in accordance with these instructions take your Inflatable PFD to a Mustang dealer for professional servicing or contact Mustang Survival see contact information on back of manual Cleaning and Storing of Your Inflatable PFD MD3075 To clean your Inflatable PFD remove the CO3 cylinder bayonet assembly Hand wash or sponge down the Inflatable PFD including inflator in warm soapy water and rinse with clean water Hang to dry on a plastic coat hanger Be sure to replace CO gt cylinder bayonet assembly See Re arming your PFD MD3075 p 6 Always store your Inflatable PFD in a warm dry place out of direct sunlight WHY ARE PFDS REQUIRED SAFETY EQUIPMENT Drownings are the leading cause of fatalities involving recreational boating A PFD provides flotation to help keep your head above water help you to stay face up in the water and increase your chances for survival and rescue Most adults only need an extra 7 to 12 pounds of flotation to keep their heads above water The proper size PFD will properly support the weight of the wearer Since this Inflatable PFD does not have inherent buoyancy it provides flotation only when inflated Familiarize yourself with the use of this Inflatable
15. n worn used and serviced according to this owner s manual this Inflatable PFD can greatly increase your chances of survival in the water Not recommended for non swimmers or weak swimmers Users of inflatable PFDs must be at least 16 years old MANDATORY CARRIAGE REQUIREMENTS Federal regulations in 33 CFR 175 1993 require you to carry Coast Guard approved personal flotation devices PFDs legibly marked with the Coast Guard approval number which are in good and serviceable condition and are the correct size for each person on board To be considered serviceable this PFD shall not exhibit deterioration that could diminish its performance such as broken or deformed hardware detached webbing rotted structural components airleaks or nonfunctional oral inflation tube Unless worn this PFD must also be properly armed with a full CO cylinder inflation system status indicator and an accessible manual inflation lanyard A PFD which is approved only when worn or required to be worn must be worn under the specified conditions WHAT IS AN INFLATABLE PFD While traditional PFDs are inherently buoyant inflatable PFDs rely entirely on inflation for buoyancy Uninflated the Inflatable PFD is a comfortable slim collar that can be inflated at any time with a 33 gram CO3 gas cylinder The Inflatable PFD is designed to offer maximum mobility with minimum bulk The Inflatable PFD IMD3075 can be inflated either manually by jerking a pull tab or
16. orally by mouth This device DOES NOT inflate automatically It is recommended that you familiarize yourself with the procedures outlined in INSTRUCTIONS FOR USE p 2 1 Inflatable PFD Owner s Manual INSTRUCTIONS FOR USE This manual supplies instructional maintenance and safety information for model MD3075 unless specified otherwise The model number is listed on the underside label Congratulations on your Inflatable PFD purchase Component Inspection Instructions 1 Examine the service indicator through the window panel Fig 1 Ensure the service indicator is green If the service indicator is red the mechanism has been fired or is incorrectly fitted see Re arming Your PFD p 6 NOTE The service indicator must be green before proceeding Undo the Velcro strips along the underside of the PFD FIGURE 1 MD3075 Service Indicator Manual Inflator Ensure the oral inflation dust cap is in the stowed position Fig 6 Ensure the service indicator is green and the pull tab lanyard is hanging on the outside Fig 1 secure the Velcro strips on the underside of the Inflatable PFD Readiness Checklist Check your Inflatable PFD and ensure all of the checkpoints listed below are true before use latable PFD Owner s Manual Service indicator is green Fig 1 No rips tears or holes all seams are securely sewn and the fabric straps and hardware are
17. r the manual inflator ADDITIONAL INFORMATION If you need more information about PFDs and safe recreational boating contact your state boating authority U S Coast Guard Auxiliary U S Power Squadron Red Cross or your nearest unit of the U S Coast Guard or call the free boating course number 1 800 336 BOAT in VA 1 800 245 BOAT DO NOT ATTACH PFD S TO YOUR BOAT Each PFD has straps hooks buckles or other means for securing the device in place on the wearer Some PFDs also incorporate decorative d rings or tabs Such items are not to be used to attach the device to the boat Attaching the device to the boat will not permit it to perform as intended AIRLINE OPERATOR POLICY ON CARRIAGE OF INFLATABLE PFDS AND CO CARTRIDGES Please be aware that the following regulations apply to the air transport of this product According to U S Research and Special Programs Administration Regulations Title 49 CFR 75 10 a 25 With the approval Inflatable PFD Owner s Manual 16 of the aircraft operator one small carbon dioxide cylinder fitted into a self inflating jacket plus one spare cartridge may be carried by a passenger or crew in checked or carry on baggage Please refer to the governing body s documentation found online at http hazmat dot gov 17 Inflatable PFD Owner s Manual WE SAVE LIVES FOR A LIVING www mustangsurvival com TOLL FREE 1 800 526 0532 EMAIL custserv mustangsurvival com Mustang Survival and sea
18. rged cylinder may not quickly or adequately inflate your Inflatable PFD Under these conditions use the oral inflator to adequately top up the PFD after CO3 inflation WARNING CO3 inflation could over pressurize and damage your Inflatable PFD if already fully inflated Re arming Your PFD IMD3075 NOTE A re arm kit MA7203 is required for this procedure IMPORTANT Follow instructions in the exact sequence below 1 Open bottom cover flap so that manual inflator is exposed Fig 7 2 Remove the cylinder bayonet assembly by rotating counterclockwise and then pull out Discard the used cylinder bayonet assembly 3 Check the new cylinder bayonet assembly to ensure the o ring is in place and the sensor ring is attached Fig 7 Ensure that the CO3 cylinder has not been pierced Fig 7 Inflatable PFD Owner s Manual FIGURE 7 3F Manual Inflator Cylinder Step 2 Sensor Ring P J Step 3 zi Bayonet Tab Step 4 O Ring A Step 3 Service m Le Indicator Prater Step 5 eR Service Indicator B If green unit is operable stor If red stop and service unit 4 Raise and hold the lever into the inflator housing Install a new cylinder bayonet assembly by engaging bayonet tabs in housing pushing in then turning clockwise 1 8 turn to a full stop Fig 8 JW WARNING PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP FIGURE 8
19. tion that could diminish its performance such as broken or deformed hardware detached webbing rotted structural components air leaks or nonfunctional inflators Unless worn inflated this PFD must also be properly armed with a cylinder installed in the inflator and service indicator showing green See Page 2 for instructions Failure to follow these instructions rigorously could result in a non functioning PFD causing injury or death Check the following at the intervals listed below 1 Before Each Use i Examine the service indicator through the window panel ensuring it is green If the indicator is red the mechanism requires service See Re arming Your PFD MD3075 p 6 9 Inflatable PFD Owner s Manual ii Ensure the manual pull tab is accessible iii Visually examine your Inflatable PFD for damage or excessive abrasion wear tear or contamination Particular attention must be paid to the stitching straps and hardware If in doubt send it to your Mustang dealer for evaluation and or servicing Every Two 2 Months i Leak Test The Inflatable PFD should be tested for general leakage by orally inflating your Inflatable PFD until firm and let stand for 16 hours A leaking Inflatable PFD will not hold its firmness and should be replaced If your Inflatable PFD leaks take it to your Mustang dealer for evaluation and or servicing Repack the Inflatable PFD as outlined in the Repacking section p 8 ii Oral Inflation Va
Download Pdf Manuals
Related Search
Related Contents
SmartVision HG2ユーザーズマニュアル Ergotron 200 Series Sliding Pivot w/ P/L. Grey 679L Liebherr Side by Side Fridge PKSBSES7253 User Manual version PDF 平成19年度における主な支出先とその内訳(PDF:1.1MB) M-Cab Serial ATA 150 Cable DeLOCK PCMCIA PCI Card, 1x CardBus Spectracide HG-63307-2 Instructions / Assembly Copyright © All rights reserved.
Failed to retrieve file