Home

Mitsubishi Electronics GT15-RS2/4

image

Contents

1. GT15 RS4 TE Mounting screw set 2 screws 2 labels Terminal block socket For handling of the ferrite core refer to For users intending to connect the GOT directly to a PLC using the RS 422 cable GT01 C30R4 25P provided with the product DIN 5265 ISO 2380 2 compliant product Recommended driver DIN 5264 Product with the tip chrome plated based on the ISO 2380 1 standard Applicable wire size 0 08 to 1 5 mm 3 Name of the Parts and External Dimen sions 1 GT15 RS2 9P PS4 9S 63 2 48 3_ GOT main o writ a ae 3 0 02 Waan 112 5 117 4 61 Dimensions of X when mounted to the GOT 8 4 23 0 91 10 4 12 1 15 21 0 83 Unit mm inch 3 Back view GT15 RS4 9S TE 0000000000 Expanded figure of part 6 6 gt ON 4 SzZdsy NO No Name Description 1 Mounting screw Mounting screws fixed with the front 9 communication unit or GOT 2 Interface Connector connected to the front communication connector unit or GOT 3 Extension Connector with which the back communication connector unit is fixed Serial Connector for connecting a serial communication 4 communication cable For GT15 RS4 TE the terminal block connector socket is connected 5 Terminal block Connects a serial communication cable to the socket serial comm
2. 6 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd RD Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea HAN NEUNG TECHNO CO LTD 1F Dong Seo Game Channel Bldg 660 11 Deungchon dong Kangsec ku Seoul Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6473 2308 Thailand F A Tech Co Ltd 898 28 29 30 S V City Building Office Tower 2 Floor 17 18 Rama 3 Road Bangkpongpang Yannawa Bangkok 10120 Tel 66 2 682 6522 Indonesia P T Autoteknindo SUMBER MAKMUR Jl Muara Karang Selatan Block a Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 Tel 62 21 663 0833 India Messung Systems Put Ltd Electronic Sadan NO 111 Unit No15 M I D C BHOSARI PUNE 411026 India Tel 91 20 712 2807 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road PostalBag No 2 Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
3. Insert the terminal block socket in the serial communication unit 2 Fasten the terminal block by tightening the terminal block fixing screws 2 places with the tightening torque of 0 20 to 0 25 Nem Expanded figure of part A A terminal block fixing screw Point When attaching or removing a communication cable to from the terminal block socket detach the terminal block socket from the connector When communication units are installed in multiple layers the units do not have to be removed from the GOT main unit Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occ
4. MITSUBISHI GT15 Serial communication unit User s Manual GT15 RS2 9P GT15 RS4 9S GT15 RS4 TE Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 RS2 4 U MODEL CODE IB NA 0800325 A 0507 MEE 1D7M40 GRAPHIC OPERATION TERMINAL GOTioo900 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause lt DANGER hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause CAUTION hazardous conditions resulting in medium or slight personal injury or physical damage ewer eee Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS Do not bunch the control
5. RECAUTIONS A CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation 1 Overview This User s Manual describes the GT15 Serial communication unit hereafter abbreviated to the serial communication unit The following shows the kinds of the serial communication unit For attachable GOTs refer to the GT15 User s Manual Model name Description GT15 RS2 9P bea The communication unitInterface D Sub GT15 RS4 9S Hy ae toner uaa unitInterface D GT15 RS4 TE oie nari communication unitInterface The serial communication unit is used when performing the serial communication between GOT and a FA device Select a serial communication unit according to the connection type For the details of connection types refer to the GOT1000 Series Connection Manual 2 Specifications 2 1 Performance Specifications The performance specifications of the serial communication unit are indicated below Refer to the used GT15 User s Manual for the general specifications of the serial communication unit Manuals The following shows manuals relevant to this product Detailed Manual M
6. acturer specified tools If the connection is incomplete it may cause the module to short circuit catch fire or malfunction Connect the connectors to the unit securely Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault STARTUP AND MAINTENANCE PRECAUTIONS Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction CAUTION Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION P
7. anual Number Manual name Type code GT15 User s Manual SH 080528ENG Option 1D7M23 Specification Item GT15 RS2 9P GT15 RS4 9S GT15 RS4 TE Transmission RS 232 RS 422 485 RS 22 485 method compliant compliant compliant D sub 9 pin D sub 9 pin A Interface Male Female Terminal block Transmission speed 115200 57600 38400 19200 9600 4800bps GOT1000 Series Connection Manual SH 080532ENG Option 1D7M26 Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software used 2005 MITSUBISHI ELECTRIC CORPORATION Synchronous type Non Synchronous type Asynchronous type Error detection method Parity check sum check Maximum transmission 15m 1200m 1200 distance Product Componets The serial commnunication units consists of the following items Model name Product mane Quantity GT15 RS2 9P GT15 RS2 9P Imternal current consumption 5V 0 20A Weight 0 09kg Mounting screw set 2 screws 2 labels GT15 RS4 9S GT15 RS4 9S Mounting screw set 2 screws 2 labels The maximum transmission distance differs depending on the controller connected For details refer to the GOT1000 Series Connection Manual 2 2 Specifications of terminal block socket Ferrite Core Item Specifications GT15 RS4 TE Screw tightening torque 0 20 to 0 25 N m
8. unication connector Switch to set terminating resistor When using the DIP switch built in terminating resistor 100Q turn both No 6 For GT15 RS4 1 and No 2 switches on When using the external 9S TE only terminating resistor turn both No 1 and No 2 switches off 7 Rating plate 4 Installation Procedure 4 1 Serial communication unit installation The following figures show an example of the GT15 RS2 9P RS4 9S installation The installation of the GT15 RS4 TE follows the same procedure 1 Power off the GOT 2 Remove the one extension unit covers of the GOT 3 Fit the Ethernet communication unit along the groove of the GOT case 4 Fasten the Ethernet communication unit by tightening its mounting screws 2 places with tightening torque 0 36 to 0 48 Nem 5 When installing a communication unit on the outer layer remove the connector cover and peel the seal When not mounting any communication unit on the outer layer stick accessory labels on the top of mounting screws 2 places to cover the top of them in order to avoid receiving electrostatic Keep the connector cover fixed Keep the seal stuck as it is Accessory labels Connector cover If you remove the serial communication unit detach it from specified direction shown PULL so as not to break a connector 4 2 Terminal block socket installation For GT15 RS4 TE only 1
9. ur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Herts AL10 8XB UK Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 20041 Agrate B Milano Italy Tel 39 039 6053344 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries LTD Tripswitch Drive Elandsfontein Gauteng South Africa Tel 27 11 928 2000 Hong Kong Ryoden Automation Ltd 10th Floor Manulife Tower 169 Electric Road North Point HongKong Tel 852 2887 8870 China Ryoden Automation Shanghai Ltd 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd Shanghai 200233 China Tel 8
10. wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction A CAUTION Use this unit in the environment given in the general specifications of the GT15 User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Use crimp contact pressure displacement or soldering to wire the connectors for external connections properly using the manuf