1. ESCUTCHEON SCREWS 2 4 Check orientation of stop valve for water flow Stop is in the off position when screwdriver slot is vertical 5 Turn water supply on Not for use with Moentrol valves Ih N SHOWER ARM ESCUTCHEON f TUB LOOKOUT NIPPLE To Eliminate Cross Piping On Back To Back Installations or To Correct Reversed Rough In Where Hot and Cold Positions Are Reversed Remove cartridge assembly rotate 180 degrees and re install see Reassembly above CAUTION MAKE SURE NOTCH ON STEM IS POINTING UP Re install retainer clip handle washer stop tube key stop and handle parts HELPLINE Call our toll free Helpline number 800 BUY MOEN 289 6636 for answers to any product installation replacement parts or warranty questions QJMOEN MT692C NOV 02 25300 Al Moen Dr North Olmsted OH 44070 8022 U S A Moen Incorporated 2002 Printed in U S A
2. 11 04 2011 MT692C Released 00 T187 T188 T189 T190 T191 T628 2320 2325 2339 2370 2375 2389 Series MT692C Models 12189 12242 12341 12342 62300 TL181 TL182 TL183 TL191 __QJMOEN INSTALLATION INSTRUCTIONS THESE INSTRUCTIONS MUST BE LEFT WITH HOMEOWNER POSI TEMP TUB AND SHOWER VALVES Available with and without stops Connections are either 1 2 inch P S pipe or 1 2 inch copper sweat connections If the Moen Slip Fit spout is used a 1 2 inch copper drop and lookout may be used Measurements These are shown in the drawings The depth measurement is critical Use the front face of the plaster ground as a reference point for the finished wall position including tile 1 3 4 44mm The supply piping centerline should be a maxium of 2 51mm and a minimum of 1 25mm behind the wall surface Use thick wall handle extension kit 96945 for wall thickness 13 16 to 1 13 16 Use handle kit 96955 for wall thickness 1 13 16 to 2 13 16 WALL LINE IMPORTANT SEE FLUSHING INSTRUC FACE OF STUD TIONS PAGE 2 FINISHED WALL SURFACE N SCREW HANDLE MONEE He 1 3 4 44mm STOP ESCUTCHEON ns TUBE 7 HANDLE WASHER TEMPER
3. ATURE 2 5 16 59mm MAX IPS SCREW LIMIT STOP Y a 2 3 16 56mm MAX CC 5 6 Y 1981mm i 1 WW PLUG fl ei eee LE I BUTTON E i KEY STOP 4 7 LJ HANDLE o ADAPTER ane P PLASTER GROUND SHOWER 45 1143mm to 48 1219mm 32 813mm FOR TUB SHOWER F COMBINATIONS AND TUB Pg see a MODELS ONLY a TUB SPOUT Loc HANDLE SCREW FLOOR Y CAP C SCREW J ap HANDLE ASSEMBLIES Always turn water off before disassembling the valve Open valve handle to relieve water RETAINER CAUTI O N i pressure and to insure that complete water shut off has been accomplished CLIP Before turning water on during either rough in or trim out make sure that cartridge retainer clip is in place The cartridge and retainer clip were properly installed and tested before leaving the factory Although it is unlikely it is never theless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed This should be carefully checked at time of rough in and trim out If the retainer clip is not properly installed water pressure could force the cartridge out of the casting Personal injury or water damage to the premises could result Visit Moen s Web Site at www moen com 11 04 2011 MT692C Released 00 Stop O pe ration WITH STOPS WITHOUT STOPS CC This type is integr
4. al with casting actuated by screwdriver and require a 90 turn to lt A ie i open or close When the screwdriver slot is vertical the rubber stop is closed and when oar SHOWER the slot is horizontal the rubber stop is open Vin seas p i i o IPS This type has been added to the basic shower casting and is actuated by a screwdriv im aN er The stop is opened by rotating in a counterclockwise direction until it stops and closed ca Aa AH SUPPLY H w e by rotating in a clockwise direction until it bottoms Af 5 7 lA Y y Ne i 4 rania TUB TUB gt Ro u g h n 2 5 16 C C amp I P S 4 4 2 2 3 4 C C lt gt P R amp I P S MAKE SURE ALL WATER SUPPLIES ARE OFF EC SIZE AND WOMINAL OPENING Note the word TOP on the casting Install casting with the TOP facing UP If the valve is to be SUPPLY SUPPLY used for a shower only plug the bottom outlet If the valve is to be used for both a shower and a tub connect the top outlet to the shower and the bottom outlet to the tub Secure all pipes and the shower and tub drop ells Use thread seal tape on all threads CAUTION e This valve is equipped with the Moen FI ushing long life POSI TEMP cartridge designed for smooth trouble free operation When soldering do not heat IMPORTANT Before closing all wall openings pressure test valve and complete sys tem using flushing instructions valve any higher than necessary to flow Pipe chips sand and ot
5. cartridge assembly A cartridge twisting tool is required for this The inner spool in the cartridge assembly should shake back and forth freely If this does not happen remove the stem assembly from the cartridge sleeve remove the cap from the stem assembly and remove the balance spool Sometimes the stem assembly may have to be jarred to free the spool Carefully clean any foreign material from the balance spool and stem assembly and reassemble ORIENT THE CLIP IN THE SPOOL AND THE see illustration CAUTION DO NOT DAMAGE O RINGS The spool should move back and forth after the stem CAP FINGERS AS SHOWN ABOVE assembly is cleaned If spool still does not free up replace the entire cartridge assembly O RINGS STEM ASSEMBLY i H Wh nd 0 HY 7 i Make sure O rings are free of foreign material and are lubricated Re assemble stem CAP assembly into cartridge sleeve Re assemble cartridge into valve See Reassembly Turn both water supplies on The valve should function properly UM 1 A Slip Fit spouts BALANCE CLIP BARS C C SPOUT The Moen Slip Fit spout is designed with an O ring seal It is specifically SPOOL designed for installation with copper water tube Lookout must be free from burrs inside and out The edge must not be rolled inward from a dull tubing cutter The outside surface must be free from nicks and scratches C C LPS Press and twist
6. her solids found in new and renovated plumbing can damage the sealing surfaces the solder Overheating may damage of the cartridge causing a leak or cause the spool to become blocked To avoid damage DO NOT the cartridge or rubber stop valves TURN ON SUPPLY VALVES until instructed below Potowing tls Clecton WIN atow you to solder without removing the car Make sure both hot and cold supplies are off Rotate the cartridge stem until the notched flat points up to tridge or rubber stop valves relieve pressure and insure complete shut off Remove the cartridge assembly see Disassembly WARNING The cartridge and rubber Slowly turn on both hot and cold supplies and thoroughly flush out the body and lines Close the hot and stop valves MUST be removed before cold supplies and replace the cartridge assembly see Reassembly turn on both supplies and check the system either brazing or resistance electric forlaaks soldering If the balancing spool becomes stuck it will be apparent at the trim out test in that the valve will deliver only a small trickle of water or it will deliver only hot or cold water If this occurs proceed as follows TET T CLIP BARS Make sure that both the hot and cold water service lines are ON Also make sure that both rubber stop valves are open stop models The valve WILL NOT OPERATE unless both supplies are ON If the valve still does not function properly turn off BOTH the hot and cold supplies and remove the
7. n water pull up on tub spout diverter knob and flush the shower riser for 15 seconds Install showerhead and check system for leaks If there are no leaks turn OFF water and remove handle and limit stop Install escutcheon plate with two screws provided Mount with the escutcheon notch UP Install limit stop see temperature limit stop section The notched flat on the cartridge stem must point DOWN when mounting handle Handle Attachment For handle style A B Mount handle on the stem and replace handle screw tightly Snap handle insert or plug button in place on the handle For handle style Mount handle adapter on the stem and replace handle screw tightly Mount handle on handle adapter and replace set screw TO REMOVE STOP VALVE Always turn water supply OFF before disassembly see disassembly Removal of stop valve 1 Remove handle parts see disassembly and escutcheon 2 Using snap ring pliers remove retaining ring from valve body 3 Grip stop valve stem with pliers and rotate slightly to remove from valve body Re Installation of new stop valve 1 Check to be sure that stop valve stem is fully seated in plug 2 Insert stop valve until fully seated beyond retaining ring groove in valve body 3 Using snap ring pliers place retaining ring in valve body making sure that ring is fully seated SHOWERHEAD LIMIT STOP
8. pull out the cartridge TEMPERATURE et a gt NOTCH TUBE LIMIT STOP compas KEY amet OC Ay KNOB HANDLE KNOB WASHER HANDLE SCREW INSERT FRONT VIEW TOP VIEW PLUG BUTTON HOT INLET Or COLD INLET iii am le FORWARD S5 TO REAR lt LEVER NEN HANDLE O c T ye never E CARTRIDGE CAUTION CARTRIDGE STEM NOTCH MUST BE INSTALLED j DOWN WITH HOT amp COLD PEISE INLETS AS SHOWN CAUTION CARTRIDGE MUST BE INSTALLED WITH HOT amp COLD INLETS AS SHOWN ee Fre CAP SCREW Reassembly Properly orient the cartridge see illustration above then re insert cartridge by pushing it all the way into the body until the front of the ears on the cartridge shell are flush and aligned with the top and bottom of the valve body Replace the retainer clip so that the legs straddle the cartridge ears and slide down into the bottom slot in the body This prevents the cartridge from rotating and locks it in the body Reinstall stop tube and parts Limit stop must be installed with offset at TOP 12 o clock position to obtain maximum hot water The notched flat on the stem must point DOWN when mounting the handle To Adjust Temperature Limit Stops CAUTION Due to seasonal temperature change of the cold water supply the temperature limit must be readjusted accordingly to maintain the desired ma
9. the spout onto the lookout upside down Tighten the clamp screw CLAMP with a 5 32 hex wrench until it just starts to bind Turn spout upright into position dzs SCREW against the wall and finish tightening the clamp screw by hand The use of pliers or O me another wrench on the hex wrench is not necessary Do not overtighten i S5 IPS SPOUT CAUTION This spout is A B S plastic and will crack when in contact with some pipe thread compounds Please read the pipe compound label to be certain We recommend using thread seal tape thread sealant Screw tub spout onto pipe and tighten by hand If final turn by wrench is needed use small wrench with smooth jaws otherwise pad wrench teeth with rag Pull outward on spout while tightening to avoid scratching wall DO NOT INSERT TOOL INTO SPOUT END TO TURN SPOUT MT692C 11 04 2011 MT692C Released 00 Disassembly Turn OFF both hot and cold water supplies then rotate handle counterclockwise until the lever points straight up to relieve pres sure Remove handle parts 1 For handle style A B remove handle insert or plug button Take out handle screw remove handle and washer For handle style C remove cap screw and handle Remove handle screw and handle adapter 2 Remove temperature limit stop key stop and stop tube Lift out retainer clip Rotate cartridge shell between the Eleven and One O Clock position with Moen cartridge twist wrench grasp the cartridge stem with pliers and
10. ximum discharge temperature 1 Rotate the handle counterclockwise to the stop let the water run for several minutes to purge cool water from the hot water supply line check the hot water temperature 2 Rotate handle clockwise to off Remove handle parts see Disassembly and temperature limit stop rotate the stop clockwise to decrease counterclockwise to increase maximum hot water temperature and reinstall into key stop 3 For handle styles A amp B replace handle for style C replace handle adapter do not use handle screws 4 Rotate the handle or handle adapter counterclockwise to the stop recheck maximum hot water temperature 5 Repeat steps 2 3 amp 4 until desired maximum temperature is achieved Install handle parts see Handle Attachment under Trim on following page ROTATE LIMIT STOP CLOCKWISE KEY STOP TEMPERATURE TO REDUCE LIMIT STOP FULL HOT POSITION m S ee fx 11 04 2011 MT692C Released 00 Trim MAKE SURE ALL WATER SUPPLIES ARE OFF TO INSTALL TRIM AFTER ROUGH IN Slide the flange onto the long end of the shower arm Wrap both ends of shower arm with thread seal tape and screw long end of shower arm into pipe ell inside the wall Do not install the showerhead Install tub spout see page 2 Remove screw holding plaster ground and stop tube guard in place and discard Temporarily teqqpeRaTuRE install handle Turn o
Download Pdf Manuals
Related Search
Related Contents
Serie Kurzanleitung - Harlander.com シングルシェード ドラム式 取扱説明書 ADATA DashDrive UV128 16GB StarTech.com 4 ft Retractable High Speed HDMI Cable with Ethernet - HDMI to HDMI manual de instrucciones con 51 _esp Aiptek PocketDV AHD Z600 Husqvarna GTH2350 User's Manual Series 40 M25 Axial Piston Pumps and Motors Service Manual 組付・取扱説明書 Hotpoint RGA724EKWH Specifications Copyright © All rights reserved.