Home

Metrologic Instruments MS863 Barcode Reader User Manual

image

Contents

1. Keyboard Wedge Cable with Adapter Cable mlpn 45 45927 Figure 1 Caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN 60950 To maintain compliance with standard CSA C22 2 No 950 UL 1950 and norm EN 60950 the power source should meet applicable performance requirements for a limited power source 10 OPTIONAL IN COUNTER MOUNTING OPTIONS FOR THE MS860 Metrologic has designed three plates to accommodate in counter installation of the MS860 Included automatically with the purchase of the MS860 is Metrologic part 45 45471 Installation Plate The universal and replacement plates are available for an additional charge Contact the distributor dealer or Metrologic customer service representative to order one of these plates Metrologic Part Number mlpn 45 45471 Installation Plate This plate is designed for use in counters with no previous cutouts No routing is necessary for a flush fit as the stainless steel top is only 60mm 024 thick The cut out measurements are 180 34 mm 7 1 L x 175 26 mm 6 9 W The final cut out must not be greater than 1 5mm 1 16 or less than the exact measurement Metrologic Part Number mlpn 45 45474 Universal Plate This plate is designed to fit into an existing cut out up to 292 1 mm 11 5
2. Metro Suzhou Technologies Co Ltd 221 Xing Hai Street Suzhou lndustria Suzhou China 215021 Japan Metrologic Japan Co Ltd Matsunova Building 6 Floor 3 14 8 Higashiueno Taitou Ku Tokyo 110 0015 Japan Park Tel 65 6842 7155 Fax 65 6842 7166 Email info sg metrologic com Tel 86 512 62572511 Fax 86 512 62571517 Email info cn metrologic com Tel 81 03 3839 8511 Fax 81 03 3839 8519 Email info jp metrologic com Rua da Paz 2059 CEP 04713 002 Ch cara Santo Ant nio etrologic do Brasil Ltda S o Paulo SP Brasil Outside Brazil Rua da Paz 2059 CEP 04713 002 Ch cara Santo Ant nio Metrologic South America S o Paulo SP Brasil Copyright Tel 55 11 5182 8226 Fax 55 11 5182 8315 Email info br metrologic com Tel 55 11 5182 7273 Fax 55 11 5182 7198 Email info sa metrologic com 2002 by Metrologic Instruments Inc All rights reserved No part of this work may be reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may guote brief passages in a review or provided for in the Copyright Act of 1976 Products and brand names mentioned in this document are trademarks of their respective companies TABLE OF CONTENTS Introduction een en nn annee een 1 Scanner and Accessories si itrereeaacaraaareaaeanaaacananana 2 Scanner Connections to the Host 3 Configuration of the Scanner to the Host
3. Metrologic METROLOGIC INSTRUMENTS INC MS860 MS863 Mini Slot Laser Bar Code Scanner Installation and User s Guide LOCATIONS North America 90 Coles Road Blackwood NJ 08012 4683 European Headguarters Metrologic Instruments Inc Customer Service 1 800 ID METRO Tel 856 228 8100 Fax 856 228 6673 Email info metrologic com Internet www metrologic com Germany Metrologic Instruments GmbH Middle East and Africa Dornierstrasse 2 82178 Puchheim b Munich Germany Edificio Diapas n 28037 Madrid Italy Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano del Emilia BO Hampshire RG2 Metrologic Eria Ib rica SL Juli n Camarillo 29 D 1 ria France SA 69 Rue de la Belle Etoile ZI Paris Nord II BP 50057 95947 ROISSY CDG CEDEX struments UK Limited 58 Tempus Business Centre Kingsclere Road Basingstoke 6XG Tel 49 89 89019 0 Fax 49 89 89019 200 Email info europe metrologic com Germany Email info de metrologic com Tel 34 913 272 400 Fax 34 913 273 829 Email info es metrologic com Tel 39 0 51 6511978 Fax 39 0 51 6521337 Email info it metrologic com Tel 33 0 1 48 63 78 78 Fax 33 0 1 48 63 24 94 Email info fr metrologic com Tel 44 0 1256 365900 Fax 44 0 1256 365955 Email info uk metrologic com Metrologic Asia Pte Ltd No 8 Kaki Bukit Place 4 Floor Singapore 416186
4. 26 35 37 Humidilty mec ee 27 I Indicators vii nia 1 LED esce 1 13 15 16 27 Installation 11 39 Interfaces 4 38 K keyboard wedge 1 9 38 L Labels neis 21 LASERKLASSE 1 21 EDS ss m 3 10 15 M Maintenance 25 27 MECCA iii 1 28 Mechanical 26 N Notices 40 41 O OGIA 5 itis hs 1 27 35 37 Operation 27 40 Operational 27 Orientation 12 26 P Parts sites E lai 13 Patents 42 Re na a na 1 9 10 33 38 Pin Assignments 3 10 35 38 Property une 42 R Red LED storno 2220 13 Repair 4 He 39 RMA pile ia een 39 RS 485 ea 1 6 37 INDEX S ScanSelect 1 2 4 7 9 14 19 38 ScanSet 1 4 7 9 14 19 38 Seicelle 39 Specifications 26 27 Stand EE 2 12 14 T Temperature 27 U UL CSA TUV ses 26 44 V Ventilation 27 Voltage 3 10 26 Volume control card 2 19 20 30 W Warranty 39 Weight 26 Window 13 NOTES NOTES August 2002 Printed in the USA 00 02202A
5. L x 508 mm 20 W Metrologic Part Number mlpn 45 45470 Replacement Plate This plate is designed to fit into a cut out that previously contained an MS260 or MS362 scanner This plate fits into the existing 293 62 mm 11 56 L x 245 36 mm 9 66 W 11 VERTICAL STAND KIT Vertical Stand Kit MLPN 45 45472 includes a Vertical Stand b 46 32 x 3 8 Phillips Head Screw c 8 x 1 00 Round Head Wood Screw Installation MLPN 45 45472 MLPN 18 18317 MLPN 18 18057 Qty 1 Qty 2 Qty 3 Present Code bottom to top Orientation Note The arrow on the top of the scanner indicates the direction that items must be presented to the scanner Present Code top to bottom Present Code right to left Present Code left to right 1 Drill four 39 pilot holes into the counter top See Figure 2 2 Screw the stand to the counter top with the four 8 wood screws provided 3 Secure the unit to the stand using the four 6 32 x 3 8 screws provided See Figure 4 6 37 MLPN 32 32324 EE Lu ago Ne Vertical Stand 127 mm 69 18 mm Z Four 8 x 1 00 e T Wood Screws d 1 V Virna Dei A 39 Drill four 4 places Figure 2 MLPN 32 32324 Vertical Stand Ra Two 6 32 x 3 8 Phillips Head Screws MS860 x MS863 Figure 3 Figure 4 12 SCANNER PARTS Touch Plate When a sp
6. host system or desk transformer Input Voltage 11 30VDC 0 50VDC Operating Current 350 mA 20VDC Standby Current 175 mA 20VDC DC Transformers Class 2 20VDC 750 mA 26 SPECIFICATIONS CONT OPERATIONAL MS860 AND MS863 SPECIFICATIONS Depth of Field 0 mm 203 mm 0 8 programmable Minimum Bar Width 0 191 mm 7 5 mil Scan Speed 2000 scan lines per second Scan Pattern 5 fields of 4 parallel lines omnidirectional Exit Angle 70 Indicators LED Green laser on ready to scan Red good read Beeper Operation 3 tones or no beep 3 volume settings Maintenance Clean window periodically Decode Capability Autodiscriminates all standard bar codes for other symbologies call Metrologic System lnterfaces RS232 OCIA OCR A B Parallel IBM 468X 469X Light Pen Emulation Point to Point RS422 Keyboard Wedge Print Contrast 35 minimum reflectance difference Roll Pitch Yaw 360 60 60 ENVIRONMENTAL Storage Temperature 40 C 60 C 40 F 140 F Operating Temperature 0 C 40 C 32 F 104 F Humidity 5 95 relative humidity non condensing Light Levels Up to 4842 Lux 450 footcandles Ventilation None required Shock 100g for 1ms ESD 8 kV IEC 801 2 Contaminants Sealed to resist airborne p
7. 228 mm RE 8 0 203 mm X 8 0 203 mm sr 7 ras CET k 6 5 165 mm I EE 6 0 152 mm E 7 0 178 mm H Ph uc S 5 0 127 mm D x j C 5 7 145 mm N Dg CEE ee 3 0 76 mm B i A X 0 0 0 mm MINIMUM BAR CODE ELEMENT WIDTH A B C D E _ mm 79 25 31 33 53 WER rs 10 12 13 21 Figure 7 Depth of Field and Symbol Specification 24 MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wipe the scanner window 25 SPECIFICATIONS MS860 AND MS863 SPECIFICATIONS Application In Counter Laser Bar Code Scanner Light Source VLD 650 10 nm Laser Power 0 525 mW peak CDRH CLASS Ila EN60825 1 1994 A11 1996 Laser Class Class 1 UL Listed UL 1950 CSA certified C22 2 No 950 ULICSATUV TUV certified GS Mark and EN 60950 EMC FCC ICES 003 amp EN 55022 Class A MECHANICAL Dimensions 175 mm 6 9 L x 173 mm 6 8 W x 97 mm 3 8 H Weight 2 45 kg 5 4 Ibs Orientation May be used in any orientation MS860 Brushed stainless steel Top Cover MS863 ABS Plastic 1 8 m 6 contact a Metrologic customer service Cable representative for additional cable options ELECTRICAL Power 8 4 W
8. EE ZE RR K ES SD SEA ER None Fujitsu OMRON sisis is RAT RI SESE SEAS IBM Parallel Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS SIEMENS XS NNN DTS NIXDORF ki NCR F NIS S S NCR S Poll Light Pen 7 Source Light Pen Extra Transition Before Bar Code 29 DEFAULT SETTINGS CONT IBM KEYBOARD LIGHT Multi drop Address Beeper Tone Normal v v v Y v v Fast Beep v v v Y Volume Setting Loudest V v v Y v v Beep Transmit Before v v v v Sequence Communication None v v 7 v Timeout Razzberry Tone v v v on Timeout Three Beeps on v v v Va vy Timeout No Beeps on v v v s Timeout SE 10Mn v v m v v s imeout No Same Symbol Timeout A V v v v v Infinite Same Symbol Timeout z V n Same Symbol Rescan Timeout v v v v v v 100 msec Same Symbol Rescan Timeout v v v v v v 200 msecs 30 DEFAULT SETTINGS CONT IBM KEYBOARD LIGHT Same Symbol Rescan Timeout S v v v v v v 500 msecs Same Symbol Rescan Timeout v v v v v v 1250 msecs Same Symbol Rescan Timeout v v v v v v 2000 msecs Scanability Off v Scan Count Mode OF d Normal Depth of v v v 7 v Field Inte
9. RTS Output 6 Reserved 7 Signal Ground 8 Reserved 9 Edit Check 10 EOT 11 Data Ready 12 Adaptor Ready 13 Earth Ground 14 Power Ground 1 15 Light Pen Source 16 Light Pen Data 17 Data 1 18 Data 2 19 Power 11 30 volts DC 20 DTR Input 21 Data 3 22 Data 4 23 Data 5 24 Data 6 25 Power Ground 2 36 SCANNER PINOUT CONNECTIONS Version 11 Pin Assignments for RS 485 The version 11 scanner head cable is terminated with a male 25 pin D type connector Connecting the scanner to the host device may reguire a communication cable The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device This can be ordered when the scanner is purchased The version 11 scanner is designed to be used primarily with IBM 46XX series of electronic cash registers It can also be configured to communicate using the full RS 232 and OCIA protocol The following is a list of the pin assignments The pin numbers are impressed on the head cable s connector PIN FUNCTION 1 AC Shield Ground 2 RS 232 Receive Input 3 RS 232 Transmit Output 4 CTS Input 5 RTS Output 6 Reserved 7 Signal Ground 8 12 Reserved 13 Earth Ground 14 Power Ground 1 15 468X B 16 468X tA 17 OCIA Clock In Return 18 OCIA Clock In 19 Power 11 30 volts DC 20 DTR Input 21 OCIA Clock Out 22 OCIA Clock Out Return 23 OCIA RDATA 24 OCIA RDATA
10. Si le calculateur du scanner se trouve en mode Stand by le contacte de la plaque de palpeur r veille le scanner et active le laser L allumage de la diode verte indique que le scanner se met en service en attente d utilisation Au bout d environ 3 secondes le scanner est pr t servir La temporisation standard de plaque de palpeur est de 10 minutes Ceci peut toutefois tre modifi avec ScanSet ou par lecture d un code barres au chapitre C du manuel de programmation ScanSelect Les dur es disponibles sont deux minutes trente minutes ou m me aucune temporisation Sensorplatte Der Scanner tritt in den Stand by Modus ein wenn er f r einen bestimmten Zeitraum untatig geblieben ist Befindet sich der Rechner des Scanners im Stand by Modus weckt die Beruhrung der Sensorplatte den Scanner und aktiviert den Laser Das Aufleuchten der gr nen Leuchtdiode zeigt an da der Scanner sich fur volle Betriebsbereitschaft einschaltet Nach etwa drei Sekunden ist der Scanner betriebsbereit Der Standard Sensorfeld Timeout liegt bei zehn Minuten Dies kann jedoch ge ndert werden durch ScanSet oder Einlesen eines Barcodes in Abschnitt C des ScanSelect Programmierhandbuchs Die verfugbaren Zeitr ume sind zwei Minuten dreif ig Minuten oder gar kein Timeout Piastra sensore Se lo scanner rimasto disattivato per un determinato periodo esso passa in modalit stand by Quando il calcolatore dello scanner si trova in modalit stand
11. System 4 Cloning e 5 Version 11 IBM 46xx Scanner 6 Configuring the MS860 11 MS863 11 Scanner 7 Configuring the IBM A6xx iaia aa 8 Version 17 Keyboard Wedge Scanner e 9 Connection of an MS860 17 Scanner to a PC 10 Optional In Counter Mounting Options for the MS860 11 Vertical Stand Kit ian nen en ei 12 Scanner Parts additus betta abd husiu n h a 13 The MS860 Touch Plate 14 KUER ee 15 VOLUMES ne EE 19 EC me I 21 Depthrof Field cit et dte bx SS eue ee Lt is dl 22 Depth of Field and Symbol Specification ea 23 Maintenance ee pec ne IRE TT 25 Specifications wn nn nee v Re eae 26 Default Settings iri Rennen 28 Scanner Pinout Connections Version 1 for RS 232 OCIA and Light Pen Emulation 35 Version 2 for Parallel Communication nenne 36 Version 11 for RS 485 cns cnni dies Le des decere sente 37 Version 17 for Keyboard Wedge RS 232 and Light Pen Emulation 38 Limited Warranty erepti deer in ln 39 Noti Ces de ea Noo M ee Za OH 40 Patents RE na ib 42 lut cosas ace IUOS i og NE ME 43 INTRODUCTION Metrologic s MS860 and MS863 laser bar code Scanners are high speed aggressive in counter scanners Both models have compact durable housings for use with applications where counter top space is li
12. cable 3 Connect the other end of the communication cable to the host device 4 Ifthe scanner will not receive power from a transformer skip to Step 5 If the scanner will receive power from an external power source check the AC input reguirements of the transformer to make sure the voltage matches the AC outlet The outlet must installed near the eguipment and be easily accessible 5 Plug the transformer into the side of the female D type connector located on the communication cable 6 Plug the transformer into the AC outlet to supply power to the scanner 7 Power up the host system Note When the scanner first receives power the LEDs will flash and then the scanner will beep once After the scanner performs this start up seguence the green LED will remain ON for a specified time indicating that the laser is ON A caution To maintain compliance with applicable standards all circuits connected to the scanner must meet the reguirements for SELV Safety Extra Low Voltage according to EN 60950 To maintain compliance with standard CSA C22 2 No 950 UL 1950 and norm EN 60950 the power source should meet applicable performance reguirements for a limited power source CONFIGURATION OF THE SCANNER TO THE HOST SYSTEM The MS860 MS863 is shipped from the factory programmed to a set of default conditions noted in the Default Settings section of this guide and in the ScanSelect Scanner Programming Guide provided
13. kann im Wohnbereich Funkst rungen verursachen in diesem fall kann vom Betrieber verlangt werden angemessene Ma amp nahmen durchf hren Standard Europeo Attenzione Questo un prodotto di classe A Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all utilizzatore opportune misure Attention Ce produit est de classe A Dans un environnement domestigue ce produit peut tre la cause interf rences radio Dans ce cas utiliseteur peut tre amen a predre les mesures ad guates 41 PATENTS Patent Information This METROLOGIC product may be covered by one or more of the following U S Patents U S Patent No 4 360 798 4 369 361 4 387 297 4 460 120 4 496 831 4 593 186 4 607 156 4 673 805 4 736 095 4 758 717 4 816 660 4 845 350 4 896 026 4 923 281 4 933 538 4 960 985 4 992 717 5 015 833 5 017 765 5 059 779 5 081 342 5 117 098 5 124 539 5 130 520 5 132 525 5 140 144 5 149 950 5 180 904 5 200 599 5 216 232 5 229 591 5 247 162 5 250 790 5 250 791 5 250 792 5 260 553 5 262 628 5 280 162 5 280 164 5 304 788 5 321 246 5 324 924 5 396 053 5 396 055 5 408 081 5 410 139 5 436 440 5 449 891 5 468 949 5 479 000 5 532 469 5 545 889 5 557 093 5 627 359 5 637 852 5 777 315 5 789 731 No license right or sublicense is granted either expressly or by implication estoppel or otherwise under any METROLOGIC or
14. located inside the window of the scanner noting that the device is a CDRH Class Ila laser product and IEC 825 LASERKLASSE 1 Another label located on the back of the unit shows the model number date of manufacture and serial number The following are samples of these labels Metrologic Metrologic Instruments Inc Blackwood New Jersey USA Contains no user servicable components Warranty void if case is opened Complies with FCC and ICES 003 Class A See manual Manufactured Blackwood NJ September 2001 L See User s Guide for patent coverage E LR 66345 DE LISTED 9448 LE CE Model MS860i 1 RS232 OCIA LTPN Barcode Scanner ti Serial 0000000000 11 30V 7 SAMPLE This product complies with US DHHS Standard 21 CFR Champter 1 Subchapter J Class Ila Laser Product Avoid long term viewing of direct laser light nach EN 60825 09 91 Eviter toute exposition prolongee de la vue au rayonnement laser direct Apparell laser Classe lla G E Sicherhet Made in U S A CAUTION Laser light when opened DO NOT STARE INTO BEAM Complies with 21 CFR Chapter 1 subchapter J Class Ila laser product Avoid long term viewing of direct laser light oo LASERKLASSE 1 Figure 5 Labels 21 DEPTH OF FIELD Through the glass at the front of the scanner safe low powered laser beams are projected in a complex pattern that resembles a spider web Each of the five scan f
15. DTR Handshaking Support lt RTS CTS Handshaking Character RTS CTS Message RTS CTS XON XOFF Handshaking ACK NAK 5 Retries on ACK NAK Time out AR AE JE RE Keyboard Country Type USA 33 DEFAULT SETTINGS CONT IBM KEYBOARD Keyboard Type Caps Lock v Alt Mode Y Inter Scan Code 800 Delay usec Transmit FOH Break Code AT x and PS 2 keyboards Special Software is required for the following Supplements Five Digit v Supplements Bookland v v 977 2 digit Supplemental v v v v v Reguirement Supplements are not v v v v v Reguired Two Digit x Redundancy V d d v m Five Digit Redundancy d v d id di 200 msec to Find v v v v v Supplement 100 msec to Find v v v v v Supplement Code 128 Coupon v v v v Extended Code Code 128 C1 Extended Code v v v v Format 34 SCANNER PINOUT CONNECTIONS Version 1 Pin Assignments for RS 232 OCIA and Light Pen Emulation The version 1 scanner head cable is terminated with a male 25 pin D type connector Connecting the scanner to the host device may reguire a communication cable The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device This can be ordered when the scanner is purchased The version 1 scanner is de
16. EBEN LIRE CE CODE POUR AUGMENTER LE VOLUME CONSERVER CETTE CARTE LEER CODIGO PARA AUMENTAR VOLUME GUARDAR ESTA CARTA QUESTO CODICE AUMENTA IL VOLUME CONSERVATE LA CARTA LER O CODIGO PARA VOLUME MAIS ALTO GUARDAR ESTE CARTAO NpockaHupy TE 3TOT KOA ANS NOBBILIEHHA TPOMKOCTH Coxpannte 3Ty KapTouky Aka fk PCR A FERMA Cu D K REZ KY LT Fa v Metrologic North American HQ Metrologic Instruments Inc 90 Coles Road Blackwood NJ 08012 Customer Service 1 800 ID METRO Tel 856 228 8100 Fax 856 228 6673 Email info metrologic com South America Metrologic South America Rua Fl rida 1821 5 Andar S o Paulo SP Brasil CEP 04571 090 Tel 5511 5505 6568 Fax 5511 5505 1681 Email info sg metrologic com Germany Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b Munich Germany Tel 49 89 89019 0 Fax 49 89 89019 200 Email info europe metrologic com Brazil Metrologic do Brasil Ltda Rua Fl rida 1821 5 Andar Sao Paulo SP Brasil CEP 04571 090 Tel 5511 5505 2396 Fax 55115507 2301 Email info br metrologic com Asia Metrologic Asia Pte Ltd 31 Kaki Bukit Road 3 05 08 Techlink Singapore 417818 Tel 65 842 7155 Fax 65 842 7166 Email info sg Metrologic com MLPN 2346 February 2000 19 VOLUME SETTINGS CONT IMPORTANT KEEP THIS CARD WITH THE SCANNER 0 Scan for Softer Volume 12345 88887 SCAN FOR SOFTER VO
17. LUME SAVE THIS CARD LEES CODE VOOR STILLER VOLUME KAART BIJHOUDEN DIESER CODE VERRINGERT DIE LAUTSTARKE BITTE KARATE AUFHEBEN LIRE CE CODE POUR BAISSER LE VOLUME CONSERVER CETTE CARTE LEER CONDIGO PARA BAJAR VOLUME GUARDAR ESTA CARTA QUESTO CODICE DIMINUISCE IL VOLUME CONSERVATE LA CARTA LER O CODIGO PARA VOLUME MAIS BAIXO GUARDAR ESTE CARTAO MMpocKaHKpyUTe 3TOT KOA ANA NOHAKEHNA TPOMKOCTH Coxpannte 3Ty kaprovky atra REA sea K tike ODIILEERZARELLT au Metrologic North American HQ Metrologic Instruments Inc 90 Coles Road Blackwood NJ 08012 Customer Service 1 800 ID METRO Tel 856 228 8100 Fax 856 228 6673 Email info metrologic com South America Metrologic South America Rua Florida 1821 5 Andar S o Paulo SP Brasil CEP 04571 090 Tel 5511 5505 6568 Fax 5511 5505 1681 Email info 3sg metrologic com Germany Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b Munich Germany Tel 49 89 89019 0 Fax 49 89 89019 200 Email info europe metrologic com Brazil Metrologic do Brasil Ltda Rua Florida 1821 5 Andar S o Paulo SP Brasil CEP 04571 090 Tel 5511 5505 2396 Fax 55115507 2301 Email info br metrologic com 8 Asia Metrologic Asia Pte Ltd 31 Kaki Bukit Road 3 05 08 Techlink Singapore 417818 Tel 65 842 7155 Fax 65 842 7166 Email info sg Metrologic com MLPN 2346 February 2000 LABELS There is one label
18. Port 5B an IBM 4500 hand held bar code reader CCD 4680 OS Port 9B or an IBM 3687 2 fixed scanner 4680 OS Port 17 that matches the configuration of your scanner Regarding the 4690 OS at the time of this printing Metrologic does not know exactly which terminal port configuration screen is used for selecting scanners It should be listed under the Port 9A 9B 9C or 9E sections The 4693 terminal has a Port 5B that was originally used for the IBM 1520 scanner While IBM has withdrawn this product it was not clear how terminal configuration and device driver support would be provided for the installed base of users Save the configuration and activate it for the desired terminals Download the configuration to the terminal s per standard procedures IBM 4684 and 4694 Systems Initialize the RIPPS drivers for a hand scanner if hand scanner emulation was selected Initialize the RIPPS drivers for a POS scanner if the 3687 2 scanner has been selected VERSION 17 KEYBOARD WEDGE SCANNER The MS860 MS863 scanner version 17 provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code eguivalent The following are the supported keyboard and country types PC Type e AT includes IBM PS 2 and compatible models 50 55 60 80 e XT e PS 2 includes IBM PC and compatible models 30 70 8556 Keyboard Country Type e USA e Germany e France e Spain e Italy e Belguim e United Kingdom e Swiss W
19. Return 25 Power Ground 2 37 SCANNER PINOUT CONNECTIONS Version 17 Pin Assignments for Keyboard Wedge RS 232 and Light Pen Emulation The version 17 scanner head cable is terminated with a male 25 pin D type connector Connecting the scanner to a PC reguires a communication cable and a transformer Connecting the communication cable to a PC may reguire an adapter cable The version 17 scanner is designed to be used as a keyboard wedge With the appropriate communication cable the scanner will also provide an RS 232 or light pen emulation interface When configuring the scanner for an interface it is necessary to set the correct parameters for that interface For further information on configuring interfaces refer to the ScanSelect Scanner Programming Guide or ScanSet Scanner Configuration Guide The following is a list of the pin assignments The pin numbers are impressed on the head cable s connector PIN FUNCTION 1 AC Shield Ground 2 RS 232 Receive Input 3 RS 232 Transmit Output 4 CTS Input 5 RTS Output 6 Reserved 7 Signal Ground 8 10 Reserved 11 PC 5 Volts DC 12 Ground 13 Earth Ground 14 Power Ground 1 15 Light Pen Source 16 Light Pen Data 17 PC Data 18 PC Clock 19 Power 11 30 volts DC 20 DTR Input 21 Keyboard Clock 22 Keyboard Data 23 24 Reserved 25 Power Ground 2 38 Limited Warranty The MS860
20. TERFACE MS860 1 MS863 1 RS 232 OCIA Light Pen Emulation MS860 2 MS863 2 Parallel Output OCR A B MS860 11 MS863 11 IBM 46XX RS 485 RS 232 OCIA MS860 17 MS863 17 Keyboard Wedge RS 232 Light Pen SCANNER AND ACCESSORIES e MS860 or MS863 Laser Bar Code Projection Scanner e Installation and User s Guide eene MLPN 00 02202 e ScanSelect Scanner Programming Guide MLPN 00 02186 e Volume Control Card errei MLPN 00 02346 e Installation Plate for MS860 models only MLPN 45 45471 Optional Accessories e Power Supply sis iii sister MLPN 00 6114A e Communication Cable for Version 1 MS860 MS863 MLPN 51 51505 e Keyboard Wedge and Adapter Cable for the MS860 17 MS863 17 sse mnes MLPN 45 45927 e Cloning Gable 22 eee eR MLPN 51 51544 e Universal Plate for MS860 models only MLPN 45 45474 e Vertical Stand WEE MLPN 45 45472 If any item is missing or to order additional items contact the dealer distributor or call Metrologic s Customer Service Department at 1 800 ID METRO or 1 800 436 3876 SCANNER CONNECTIONS TO THE HOST STOP To avoid potential problems do not power up the scanner until the communication cable is secured to the host 1 Turn off the host system 2 Connect the 25 pin D type connector on the scanner s head cable to the communication
21. The default settings in the ScanSelect guide have an asterisk that appears before the brief definition next to the bar code Since each host system is unigue the scanner will need to be configured to match the specific host system s reguirements If using ScanSet refer to the ScanSet documentation for information on how to configure the scanner To configure the MS860 MS863 1 Connect the scanner to the host system refer to page 3 2 Enter program mode by scanning the ENTER EXIT program mode bar code the unit will beep three times 3 Scan the appropriate bar code s that appear in the ScanSelect Scanner Programming Guide Note Reveal only one bar code to the scanner at a time With your hand cover the bar code that is not to be scanned 4 Exit program mode by scanning the ENTER EXIT program mode bar code again Note Non RS 232 interfaces chosen in Section B of the ScanSelect Programming Guide do not match the default settings that are loaded when the same interface is selected with ScanSet CLONING FEATURE The cloning feature is used to program several scanners with the same settings To clone a scanner 1 Turn OFF the power to both scanners by unplugging the transformers Connect the cloning cable MLPN 51 51544 between the two scanners Turn ON the power to both scanners by plugging in the transformers When each scanner is ready scan the cloning bar code with the scanner that has the settings that need t
22. Verwendung anderer als der hier beschriebenen Steuerungen Einstellungen oder Verfahren kann eine gefahrliche Laserstrahlung hervorrufen Der Kunde sollte unter keinen Umst nden versuchen den Laser Scanner selbst zu warten Sehen Sie niemals in den Laserstrahl selbst wenn Sie glauben da der Scanner nicht aktiv ist ffnen Sie niemals den Scanner um in das Ger t hineinzusehen Wenn Sie dies tun k nnen Sie sich einer gef hrlichen Laserstrahlung aussetzen Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung 40 NOTICES CONT A Attenzione L utilizzo di sistemi di controllo di regolazioni o di procedimenti diversi da guelli descritti nel presente Manuale pu provocare delle esposizioni a raggi laser rischiose II cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser Non guardate mai il raggio laser anche se credete che lo scanner non sia attivo Non aprite mai lo scanner per guardare dentro apparecchio Facendolo potete esporVi ad una esposizione laser rischiosa L uso di apparecchi ottici equipaggiati con raggi laser aumenta il rischio di danni alla vista European Standard Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Funkstoreigenschaften nach EN 55022 1998 Warnung Dies ist eine Einrichtung der Klasse A Diese Einrichtung
23. and MS863 scanners are manufactured by Metrologic at its Blackwood New Jersey U S A facility The MS860 and MS863 scanners have a two 2 year limited warranty from the date of manufacture Metrologic warrants and represents that all MS860 and MS863 scanners are free of all defects in material workmanship and design and have been produced and labeled in compliance with all applicable U S Federal state and local laws regulations and ordinances pertaining to their production and labeling This warranty is limited to repair replacement of Product or refund of Product price at the sole discretion of Metrologic Faulty eguipment must be returned to the Metrologic facility in Blackwood New Jersey U S A or Puchheim Germany To do this contact Metrologic s Customer Service Repair Department to obtain a Returned Material Authorization RMA number In the event that it is determined the eguipment failure is covered under this warranty Metrologic shall at its sole option repair the Product or replace the Product with a functionally eguivalent unit and return such repaired or replaced Product without charge for service or return freight whether distributor dealer reseller or retail consumer or refund an amount egual to the original purchase price This limited warranty does not extend to any Product which in the sole judgement of Metrologic has been subjected to abuse misuse neglect improper installation or accident nor any damage d
24. articulate contaminants Specifications subject to change without notice 27 DEFAULT SETTINGS Many function of the scanner can be programmed that is enabled or disabled The scanner is shipped from the factory programmed to a set of default conditions The default parameter of the scanner has an asterisk in the charts on the following pages If an asterisk is not in the default column then the default setting is OFF or DISABLED Every communication does not support every parameter If the communication supports a parameter listed in the charts on the following pages a check mark will appear IBM KEYBOARD m LIGHT v Y Y v v v UPC EAN Code 128 i v Code 93 m v Y Y v v Codabar x v Y Y v v Interleaved 2 x of 5 ITF V y d id MOD 10 Check KS on ITF Code 11 v Y v v v Code 39 ki v Y Y v v Full ASCII Code 39 d d v t d MOD 43 Check on Code 39 V Y v MSI Plessey v v v v v MSI Plessey 10 10 Check v v v v v Digit MSI Plessey MOD 10 Check v v v v v Digit UK Plessey v v v v Airline 2 of 5 v Y v VA Telepen v v v v MECCA v v v v v v 28 DEFAULT SETTINGS CONT IBM KEYBOARD LIGHT Paraf Support Matrix 2 of 5 EAN 8 ki EAN 13 xd UPC E i UPC A id ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock SWEDA i Var 04 S S SISISISISIS SIA RRR E SEE
25. by occorre toccare la piastra sensore per svegliare lo scanner ed attivare il laser L accensione del diodo luminoso verde indica che lo scanner si accende per diventare completamente pronto Dopo circa tre secondi lo scanner ha raggiunto la condizione pronto Il timeout standard della zona sensore regolato su dieci minuti Questo valore pu per essere modificato con lo ScanSet oppure con la lettura di un codice a barre come descritto nella sezione C del Manuale di programmazione ScanSelect Gli intervalli possibili sono due minuti trenta minuti oppure nessun timeout 14 VISUAL INDICATORS There is a red and green LED at the top of the scanner When the scanner is on the flashing or stationary activity of the LEDs indicates the status of the scan and scanner Steady Green When the laser is on the green LED is also on This occurs when the touch plate has been touched The green LED will remain on until the touch plate timeout elapses or until the scanner turns off Steady Green Red Flash When the scanner successfully reads a bar code the red LED will flash then beep once If this does not happen then the bar code has not been successfully read Steady Red and Green After a successful scan the scanner transmits the data to the host device When the host is not ready to accept the information the scanner s red LED will remain on until the data can be transmitted Alternating Red and Green This indicates the sca
26. de 39 and Interleaved 20f5 l2 of 5 The Version 11 scanner formats Codabar Code 128 and Code 93 using the Code 39 function code designation supported by the IBM device driver for this scanner type Other emulation modes currently available are the IBM 3687 2 Port 17 fixed scanner and the Port 9B IBM 4500 CCD hand held bar code reader The use one of these other emulation modes may be needed depending on which operating system 4680 0S 4690 0S POS DOS or DOS RIPPS is in use at your site Note The IBM 4683 and IBM 4684 terminals have a good proven track record of supplying power to Metrologic scanners The IBM 4693 and IBM 4694 terminals may be restricted from supplying power to certain scanner models Specifically Metrologic currently recommends using an external power supply for the scanner when connecting to an IBM 4694 Metrologic has no recommendations at this time for IBM 4693 terminals CONFIGURING THE MS860 11 MS863 11 SCANNER Located in the Version 11 scanner are two computer boards One computer board is for decoding and the other for 46XX IO processing The decode board is configured using ScanSet or ScanSelect while the IO board is configured with an internal DIP Switch bank For UPC EAN scanning the decode board should be set as follows Enable IBM 4680 Communication Enable UPC EAN Beep after Transmit Enable Communication Timeouts Transmit UPC A Check Digit Transmit UPC E Check Digit These settings configure the dec
27. ecified time has elapsed without any scanning the unit will enter a standby mode Touching the touch plate arrow on the top cover will reactivate the scanner Red LED When the red LED flashes ON the scanner has read a bar code successfully When the red light turns OFF communication to the host is complete Green LED When the green LED is ON this indicates the unit is receiving power and the laser is ON Output Window This aperture emits laser light Head Cable This cable can be connected directly to the host device or to a communication cable Stainless Steel Top Plate On the MS860 only Dark Grey ABS Top Plate On the MS863 only MS860i MS863 Figure 5 MS860 8 MS863 Scanner Parts 13 The MS860 ToucH PLATE The MS860 will enter standby when it remains dormant for a time When the scanner s computer is on standby touching the touch plate will wake up the scanner and activate the laser When the green LED comes on the scanner is powering up for full operation After approximately three seconds the scanner will be ready to operate The default touch plate timeout is ten minutes However this can be changed through ScanSet or by scanning a bar code in Section C of the ScanSelect Programming Guide The available times are two minutes thirty minutes or no timeout Plague de palpeur Le scanner passe en mode Stand by quand il n est pas utilis pendant une certaine p riode
28. ields that generate the scan pattern extend to a range of 127mm 5 0 This range begins from the face of the scanner window and extends from the unit for a distance of 127mm 5 0 measured along the scanning beam at the center of each scan segment This 0 0mm 127mm 0 5 range is the depth of field for the MS860i scanner see figure 6 The scan pattern is projected at an angle away from the touch plate approximately 20 degrees overall As the scan fields move outward they expand Like an image expands from a film projector as it moves toward the screen at a movie theater the scan pattern projects out to a well defined region Any label that is facing toward the scanner can be read at any point within the scanning field Figure 6 Depth of Field 22 DEPTH OF FIELD AND SYMBOL SPECIFICATION CODE TYPE MINIMUM SMALL ELEMENT COLE DENSITY DEPTH OF MiL 1 1000 FIELD UPC EAN 10 4 8096 0 5 UPCIEAN 13 0 100 0 6 5 Code 39 7 5 High 0 3 Code 39 12 0 Medium 0 6 Code 39 21 0 Low 0 8 2 0f5 7 5 High 0 3 2 0f5 12 0 Medium 0 6 2 0f5 21 0 Low 0 8 Codabar 6 5 High 0 3 Codabar 9 8 Medium O 5 Codabar 13 0 Low 0 6 5 Code 93 10 4 80 0 5 Code 93 13 0 100 0 6 5 Code 128 10 4 80 0 5 Code 128 13 0 100 0 6 5 23 DEPTH OF FIELD AND SYMBOL SPECIFICATION Width of Scan Field Distance from Face 9 0
29. ith the appropriate communication cable the scanner will also provide an RS 232 or light pen emulation interface When configuring the scanner for one interface versus another change all necessary parameters for that particular interface For instance when configuring the scanner for keyboard wedge emulation recall defaults select the PC type keyboard country type and intercharacter delay For further information refer to the ScanSelect Scanner Programming Guide or ScanSet Scanner Configuration Guide CONNECTION OF A MS860 17 SCANNER TO A PC If the PC is on exit your application and turn the PC off Disconnect the keyboard from the PC Plug the Keyboard Wedge cable to the PC and the keyboard Use the adapter cable if necessary Connect the 25 pin D type connector on the scanner s head cable to the Keyboard Wedge cable Check the AC input reguirements of the transformer to make sure the voltage matches the AC outlet A socket outlet should installed near the eguipment and be easily accessible Plug the transformer into the side of the female D type connector located on the communication cable Plug the transformer into the AC outlet to supply power to the scanner Turn the PC on When the scanner first receives power the LEDs will flash and the scanner will beep once After the scanner performs this start up seguence the green LED will remain on for a specified time indicating the laser is on MS860 17 Z A MS863 17
30. l info europe metrologic com Munich Germany 39 NOTICES Notice This eguipment has been tested and found to comply with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the eguipment is operated in a commercial environment This eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this eguipment in a residential area is likely to cause harmful interference in which case the user will be reguired to correct the interference at his own expense Any unauthorized changes or modifications to this eguipment could void the users authority to operate this device This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Notice This Class A digital apparatus complies with Canadian ICES 003 Remargue Cet appareil num rigue de la classe A conform a la norme NMB 003 du Canada A Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure Under no circumstances should the cu
31. mited The MS860 and MS863 autodiscriminate all standard bar codes Each model includes a code correcting feature MECCA that enables the scanner to decode damaged or truncated codes on the first pass Both models can be programmed by using the bar code menus from the ScanSelect Programming Guide or by using Metrologic s ScanSet IBM compatible software program The MS860 has a brushed stainless steel top plate with an optional universal adapter plate available for purchase that makes it simple to replace older larger flatbed scanners with the smaller MS860 The MS860 also has a unique Touch on power save mode and easily visible LED indicators mounted on the brushed stainless steel top plate The MS863 has a dark gray plastic top instead of the brushed stainless steel of the MS860 The MS863 also uses IR activation An optional hardened glass window is available for both models Metrologic also provides a vertical mounting option so customers can use the MS860 or MS863 as a projection scanner Each version of the MS860 provides three interface options with full RS 232 protocol available on every scanner RS 232 OCIA and Light Pen Emulation are consolidated into the standard model For simple PC connectivity a keyboard wedge interface is also available Metrologic also offers a patented Hand Held Option which allows users to connect the MS941 Hand Held Scanner to the MS860 or MS863 for greater scanning versatility MODEL IN
32. nanzeigen nicht aufleuchten Erstens Wenn der Scanner mit Strom versorgt wird und die Leuchtdiodenanzeigen nicht aufleuchten so ist der Scanner f r einen bestimmten Zeitraum untatig geblieben und der Laser ist abgeschaltet Ber hren Sie das Sensorfeld zur Reaktivierung der Einheit Zweitens Wenn der Scanner weder vom Hostrechner noch vom Transformator Energie erhalt leuchten die Leuchtdiodenanzeigen ebenfalls nicht auf Feststehende gr ne Anzeige Wenn der Laser eingeschaltet ist leuchtet die gr ne Leuchtdiodenanzeige ebenfalls auf Dies ist der Fall wenn das Sensorfeld ber hrt wurde Die gr ne Leuchtdiodenanzeige leuchtet solange auf bis das Sensorfeld Timeout abgelaufen ist oder bis der Scanner abgeschaltet wird Feststehende gr ne Leuchtanzeige rote Blinkanzeige Nach erfolgreichem Lesen eines Barcodes durch den Scanner blinkt die rote Leuchtdiode auf gefolgt von einem einmaligen Piep Signal Blinkt die rote Leuchtdiodenanzeige nicht auf oder sendet der Scanner kein einmaliges Piep Signal aus so konnte der Barcode nicht erfolgreich gelesen werden Feststehende rote und gr ne Leuchtanzeige Nach erfolgreichem Abtasten Ubertragt der Scanner die Daten an das Hostgerat Falls das Hostgerat zur Datenannahme nicht bereit ist leuchtet die rote Leuchtdiodenanzeige solange auf bis die Daten bertragen werden k nnen Alternierende rote und griine Leuchtanzeige Zeigt an da sich der Scanner im Programmiermodus befindet Fests
33. ndi viene emesso un unico segnale beep Se il diodo luminoso rosso non lampeggia oppure lo scanner non emette un segnale beep unico ci significa che la lettura del codice a barre non riuscita Sono accesi sia il diodo luminoso rosso che quello verde Dopo la scansione riuscita lo scanner trasmette i dati al host Se l host non pronto per accettare i dati il diodo luminoso rosso dello scanner acceso fino a che i dati possono essere trasmessi II diodo luminoso rosso e quello verde sono accesi in alternanza Ci indica che lo scanner si trova nella modalit di programmazione Il diodo luminoso rosso acceso Ci indica che lo scanner si trova nella modalit ScanSet Il diodo luminoso rosso lampeggia Ci indica che lo scanner ha un guasto a livello del laser Fate riparare l apparecchio da un centro di assistenza autorizzato 18 VOLUME SETTINGS There are four volume settings available low medium high and no volume The operator can temporarily change the volume of the scanner by scanning the bar codes on the volume control card To change the volume of the scanner permanently enter program mode and scan the appropriate volume setting bar code in Section C of the ScanSelect Programming Guide or use ScanSet IMPORTANT KEEP THIS CARD WITH THE SCANNER Il IL 0 12345 lll SCAN FOR LOUDER VOLUME SAVE THIS CARD LEES CODE VOOR LUIDER VOLUME KAART BIJHOUDEN DIESER CODE ERHOHT DIE LAUTSTARKE BITTE KARTE AUFH
34. nner is in program mode Steady Red This indicates the scanner is in ScanSet mode No Red or Green LED There are two reasons why the LEDs will not be illuminated First if the scanner is receiving power and the LEDs are not on then the scanner has remained dormant for a specified time and the laser has turned off To reactivate the unit touch the touch plate Secondly if the scanner is not receiving power from the host or transformer then the LEDs will not turn on Flashing Red This indicates the scanner has experienced a laser subsystem failure Return the unit for repair at an authorized service center 15 VISUAL INDICATORS Signaux optigues Sur la partie superieure du scanner se trouvent une diode LED rouge et une diode LED verte Quand le scanner est sous tension les diodes rouge et verte clignotantes ou allum es vous informent sur l tat du scanner Ni la diode rouge ni la diode verte n est allum e Il existe deux raisons possibles pour que les diodes ne s allument pas Premi rement si le scanner regoit de nergie sans que les diodes ne s allument le scanner est rest sans servir pendant une certaine p riode et le laser est d sactiv Pour le r activer touchez le palpeur infrarouge Deuxi mement quand le scanner ne recoit de nergie ni de ordinateur central ni du transformateur les diodes restant teintes Diode verte reste allum e Quand le laser est en service la diode verte s allume galemen
35. o be transferred to the other scanner CLONING W i VERSION 11 IBM 46XX SCANNER Output Format IBM RS 485 serial input output for the 4680 and 4690 46XX point of sale terminals The Version 11 46XX interface can be used in several different ways Both the 46XX terminal and the scanner must be configured to match each other Warning Power to the scanner and 46XX terminal should be turned off before making physical connection The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners Scanner ports include Port 5B Port 17 and Port 9 A B C or E A Port 9 type connector is present on all versions of the 46XX families of terminals That is one reason why it is the normal point of connection for Metrologic scanners Another reason is that there is enough 12 volt power available to operate many Metrologic scanners If your terminal configuration reguires the use of a different physical port for connecting bar code scanners contact Metrologic to get particular adapter cable information All devices use a common communications bus inside the 46XX terminal despite what port that is in use for the physical connection Each device has a different address that it uses when it communicates The terminal must be configured to look for a device at a logical address The IBM 1520 mode address was selected as a default because it was the first IBM 46XX family scanner to support UPC EAN Co
36. ode board to beep after transmitting the data to the terminal device driver If the data does not clear the communications buffer within two seconds it is discarded without giving the operator a good scan indication This accommodates newer versions of the IBM device drivers that enable disable scanning in many different situations The default setting of the interface board is to emulate the IBM 1520 hand scanner that supports UPC EAN and alphanumeric code types The following is a list of switch settings for the internal interface board that handles the 46XX SIOC communications There are eight DIP switches on the board that are both software and hardware switches Switch 1 Switch 2 Emulation Mode OFF OFF Li Model 2 Laser Scanner OFF ON Port 9B CCD IBM 4500 Opticon ON OFF Port 17 IBM 4014 Adapter for 3687 2 to 468X ON ON Reserved Switch 3 Reserved Should be OFF Switches 4 5 6 and 7 Must be ON Switch 8 Should be OFF Reserved CONFIGURING THE IBM 46XX The 4683 and 4693 terminals are configured on the store controller The 4684 and 4694 terminals are typically configured on the individual terminals Follow the appropriate guide for your type of eguipment IBM 4683 and 4693 Terminals Driven by a 46XX Store Controller Running 4680 OS or 4690 0S Access the terminal configuration menu on the store controller If not already selected select an IBM 1520 laser hand scanner 4680 OS
37. rcharacter i msec Z v v Delay Scan Buffer 1 v v v v v v Transmit UPC A x Check Digit d d Y lt Transmit UPC E Check Digit v Y v d id Expand UPC E v v V4 v v Convert UPC A to EAN 13 d k x ve d Transmit Lead Zero on UPC E x d e s d Convert EAN 8 to EAN 13 v Y d Y d Transmit EAN 13 Check Digit Y Ka S S 31 DEFAULT SETTINGS CONT IBM KEYBOARD LIGHT Transmit EAN 8 Check Digit Transmit UPC A Number System Y di Y Transmit Codabar Start Stop d v V d v Characters Transmit Mod 43 Check Digit on v v v v Code 39 Transmit Code 39 Stop Start v v v v Characters Transmit Mod 10 ITF d Y v Transmit Code 11 Check Digit d Mi d Transmit MSI Plessey Check v v v v Digits Transmit UK Plessey Check v Y v Digits lt Parity Space Baud Rate 9600 8 Data Bits NPN SN S 7 Data Bits Transmit Sanyo v ID Characters lt Shell Schulmberger v v Formatting SNI Beetle Mode v v 32 DEFAULT SETTINGS CONT IBM KEYBOARD LIGHT CLSI Editing French PC Term lt Transmit AIM ID Characters Nixdorf ID UPC Prefix UPC Suffix STX Prefix ETX Suffix Carriage Return Line Feed Tab Prefix Tab Suffix SISSI SNS SS AJ S SK DE Disable Command NISISISISI SI s S S al lt FL Laser Enable Command lt
38. signed to be used for RS 232 OCIA or Light Pen Emulation communication The following is a list of the pin assignments The pin numbers are impressed on the head cable s connector PIN FUNCTION 1 AC Shield Ground 2 RS 232 Receive Input 3 RS 232 Transmit Output 4 CTS Input 5 RTS Output 6 Reserved 7 Signal Ground 8 12 Reserved 13 Earth Ground 14 Power Ground 1 15 Light Pen Source 16 Light Pen Data 17 OCIA Clock In Return 18 OCIA Clock In 19 Power 11 30 volts DC 20 DTR Input 21 OCIA Clock Out 22 OCIA Clock Out Return 23 OCIA RDATA 24 OCIA RDATA Return 25 Power Ground 2 35 SCANNER PINOUT CONNECTIONS Version 2 Pin Assignments for Parallel Communication The version 2 scanner head cable is terminated with a male 25 pin D type connector Connecting the scanner to the host device may reguire a communication cable The communication cable may include a connection for a transformer or it may be designed to draw power directly from the host device This can be ordered when the scanner is purchased The version 2 scanner is designed to be used for Parallel communication The following is a list of the pin assignments The pin numbers are impressed on the head cable s connector PIN FUNCTION 1 AC Shield Ground 2 RS 232 Receive Input 3 RS 232 Transmit Output 4 CTS Input 5
39. stomer attempt to service the laser scanner Never attempt to look at the laser beam even if the scanner appears to be nonfunctional Never open the scanner in an attempt to look into the device Doing so could result in hazardous laser light exposure The use of optical instruments with the laser eguipment will increase eye hazard A atenci n La modificaci n de los procedimientos o la utilizaci n de controles o ajustes distintos de los especificados agu pueden provocar una luz de l ser peligrosa Bajo ninguna circunstancia el usuario deber realizar el mantenimiento del l ser del esc ner Ni intentar mirar al haz del l ser incluso cuando este no est operativo Tampoco deber abrir el esc ner para examinar el aparato El hacerlo puede conllevar una exposici n peligrosa a la luz de laser El uso de instrumentos pticos con el eguipo laser puede incrementar el riesgo para la vista A Attention L emploi de commandes r glages ou proc d s autres que ceux d crits ici peut entra ner de graves irradiations Le client ne doit en aucun cas essayer d entretenir lui m me le scanner ou le laser Ne regardez jamais directement le rayon laser meme si vous croyez gue le scanner est inactif Nouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous exposez une rayonnement laser gu est hazardous L emploi appareils optigues avec cet guipement laser augmente le risgue endommagement de la vision A Achtung Die
40. t C est le cas quand vous avez touch le palpeur La diode verte reste allum e tant que la temporisation de l infrarouge dure ou jusqu ce que le scanner soit d sactiv Diode verte reste allum e diode rouge clignotante Apr s lecture avec succ s d un code barres par le scanner la diode rouge se met clignoter suivie d un bip sonore unique Si la diode rouge ne clignote pas ou quand aucun bip sonore n est mis cela signifie que le code barres n a pas pu tre lu avec succ s Diode rouge et verte reste allum es Une fois le palpage effectu avec succ s le scanner transmet les donn es l ordinateur central Si ce dernier n est pas pr t recevoir les donn es la diode rouge du scanner s allume jusqu ce que les donn es puissent tre transmises Diode rouge et verte en alternance Indique que le scanner se trouve en mode de programmation Diode rouge reste allum e Indique que le scanner se trouve en mode ScanSet Diode rouge clignotante Indique une panne de laser pendant le palpage Veuillez envoyer votre appareil chez un concessionnaire pour r paration 16 VISUAL INDICATORS Optische Anzeigen Auf dem Scanner befinden sich eine rote und eine grune Leuchtdiodenanzeige Bei eingeschaltetem Scanner geben lhnen die blinkenden oder feststehenden Leuchtdiodenanzeigen Aufschlu uber den Abtast und Scannerstatus Weder rote noch gr ne Leuchtdiodenanzeige Es gibt zwei m gliche Gr nde weshalb die Leuchtdiode
41. tehende rote Leuchtanzeige Zeigt an da sich der Scanner im ScanSet Modus befindet Aufblinkende rote Leuchtanzeige Zeigt an da beim Scanner ein Laserausfall vorliegt Bringen Sie das Ger t zur Reparatur in ein Vertragsservicecenter 17 VISUAL INDICATORS Segnali ottici Sullo scanner si trovano due diodi luminosi uno rosso e uno verde Ouando lo scanner inserito i diodi luminosi che possono o essere accesi in continuazione o lampeggiare Vi informano sullo stato della scansione e del apparecchio Ne il diodo luminoso rosso ne guello verde sono accesi Vi sono due possibili cause se i diodi luminosi non sono accesi Prima causa se lo scanner viene alimentato e i diodi luminosi non sono accesi lo scanner rimasto disattivato per un determinato periodo e il laser spento Per riattivare l unit dovreste toccare la zona sensore Seconda causa se lo scanner non viene alimentato n dal calcolatore host n dal trasformatore i due diodi luminosi non sono accesi II diodo luminoso verde acceso Quando il laser inserito acceso anche il diodo luminoso verde Questo si ha quando la zona sensore stata toccata Il diodo luminoso verde acceso fino al raggiungimento del timeout della zona sensore oppure fino allo spegnimento dello scanner Il diodo luminoso verde acceso quello rosso lampeggia Dopo la lettura riuscita di un codice a barre da parte dello scanner il diodo luminoso rosso lampeggia e qui
42. third party intellectual property rights whether or not such third party rights are licensed to METROLOGIC including any third party patent listed above except for an implied license only for the normal intended use of the specific eguipment circuits and devices represented by or contained in the METROLOGIC products that are physically transferred to the user and only to the extent of METROLOGIC s license rights and subject to any conditions covenants and restrictions therein 42 INDEX A Adapter Cable 1 6 10 38 Application 10 B Bar codes 1 19 27 BASES PC 8 Beeper 3 4 7 10 15 18 27 C Cable 3 5 9 10 13 26 35 38 adapter 1 6 10 38 fe e ul pe fiale ahi 5 communication 1 4 7 10 13 28 35 38 Caution 3 10 GE lice hee at 40 Classe li 41 Communications buffer 7 Communications bus 6 Compliance 3 10 39 Configuration 6 8 Customer Service ii 39 D Default settings 4 E Electrical 39 ES BEE el atika 27 External Power supply 6 G Good read 27 Green LED 3 10 13 14 15 H Host 3 4 13 15 18
43. ue to use or misuse produced from integration of the Product into any mechanical electrical or computer system The warranty is void if the case of Product is opened by anyone other than Metrologic s repair department or authorized repair centers THIS LIMITED WARRANTY EXCEPT AS TO TITLE IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES EITHER EXPRESS OR IMPLIED AND SPECIFICALLY EXCLUDES WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FORA PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE OR ARISING OUT OF CUSTOM OR CONDUCT THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEGUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES TO PERSON OR PROPERTY OR EFFECT ON BUSINESS OR PROPERTY OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT EXCEPT AS STATED IN THIS WARRANTY IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN Corporate Headguarters Metrologic Instruments Inc Customer Service 1 800 ID METRO 90 Coles Road Tel 856 228 8100 Blackwood NJ 08012 4683 Fax 856 228 6673 Email info metrologic com Website www metrologic com Germany Metrologic Instruments GmbH Tel 49 89 89019 0 Dornierstrasse 2 Fax 49 89 89019 200 82178 Puchheim b Emai

Download Pdf Manuals

image

Related Search

Related Contents

User Manual  ユーザーズマニュアル [PDF形式]  Samsung 305T User Manual  Para o cabo de interface USB  Manuel d`utilisation  AUTORISATION DU DROIT DES SOLS  Globe Electric 64300 Installation Guide  ホームAVサーバ スタートガイド  ARTICLE 251. CLASSIFICATION ET DEFINITONS  Manual de Instruções do Usuário  

Copyright © All rights reserved.
Failed to retrieve file