Home
LSI SAS2 Computer Hardware User Manual
Contents
1. Refer to Chapter 4 for more information about Integrated Striping volumes The SAS2 BIOS CU is part of the Fusion MPT BIOS When the BIOS loads during boot and you see the message about the LSI Configuration Utility press Ctrl C to start the CU After you do this the message changes to Please wait invoking SAS Configuration Utility After a brief pause the main menu of the SAS2 BIOS CU appears On some systems however the following message appears next LSI Corp Configuration Utility will load following initialization In this case the SAS2 BIOS CU loads after the system completes its power on self test You can configure one or two Integrated RAID volumes on each LSI SAS2 controller For a two volume configuration you can have two Integrated Striping RAID 0 volumes two mirrored volumes or one volume of each type The two volumes can have a maximum of 14 disk drives This configuration includes one or two hot spare disks for mirrored volumes The following guidelines apply when creating an Integrated Striping volume All physical disks in an Integrated Striping volume must be either SATA with extended command set support or SAS with SMART support You cannot combine SAS and SATA disks in the same volume However you can create one volume with SAS disks and a second volume with SATA disks on the same controller Page 25 Chapter 5 Creating Integrated Striping Volumes Creating Integrated Striping Volumes SA
2. Select View Existing Array The View Array window appears If necessary press Alt N to switch to another array on this adapter Select Manage Array The Manage Array window appears Select Manage Hot Spares which is the first option as shown in the following figure Page 17 Chapter 3 Creating Mirrored Volumes Managing Hot Spare Disks SAS2 Integrated RAID Solution User Guide LSI Corp Config Utility Identifier LSILOGIC Logical Volume 3000 Type RAID 1 Size GB XXXXXXX Status Optimal Figure 6 Manage Array Window The Manage Hot Spares window appears 6 Identify a disk that is not part of a RAID volume i e the value in the Drive Status column is not RAID and that is not already identified as a hot spare disk A global hot spare disk must have 512 byte blocks and nonremovable media The disk type must be either SATA with extended command set support or SAS with SMART support 7 Select the Hot Spr Hot Spare field for this disk and press the space bar The Hot Spare status changes to Yes Optional Repeat the preceding step to select a second global hot spare disk Press C to create the hot spare disk A menu window appears An error message appears if the selected disk is not at least as large as the smallest disk used in the existing volume s An error message also appears if you try to add a SATA disk as a hot spare for volumes that use SAS disks or vice versa 10 Select Save changes then exit this
3. Copyright 2010 LSI Corporation All Rights Reserved SAS2 Integrated RAID Solution User Guide Table of Contents Table of Contents Chapter 1 Introduction to the Integrated RAID Solution 5 Ree EE 5 1 2 Behefits and Features xd EE HEEN ee cvs seas BN NEEN EEN Reap aM vad BEN eyed apa de LENERS 6 T2 Host Interface ives caries san SEN Wo cea ere ER wane eine EEN e ENNEN EN EEN GENEE 6 132 2 Metadata SUP POM EE 6 UE Ee e EE EE 6 12 4 FUSIONS MPT SUDDO resi e av eels dee vets ee oe e ele Gen ed MAPS Roda Mareen e soe 6 Chapter 2 Overview of Integrated RAID Mirrored Volumes 0 0 cece ccc eenen een ene cnet eee b seen eee e nent en eaee 7 K luese te de EE H 2 2 Integrated Mirroring and Integrated Mirroring Enhanced Features 7 2 3 Operation of Mirrored Volumes neg dE ENEE Bate ag EEN doen enue cody RAG Neb uae vena g Meee weds EEA 8 2 4 Mirrored Volume Features t SEENEN NNN ENNEN EEN any eee TERE gape maui NENNEN eh Ed Se 11 2 4 1 Resynchronization with Concurrent Host I O Operation 11 24 2 HOt SWAPPING ET EE 11 24 3 Hot Spare Disk nde AEN ett Eet Arbecht A AEN SEENEN balance ade bina 4 han g tt 11 2 44 Online Capacity Expansions EE EE 11 24 5 Meel leefeg AE NEEN deme ENEE ANE e EE HEEN ENEE EEN sane gaits 11 2 46 Disk Write Caching 2 d Negi d EEN EE EEN ENTENTE d EAR ENEE AE ee Ce 12 24 7 NVSRAM Deet dee EES EE on bt KEE wade du EOE EE Ee ato 12 24 8 Background Initialization 33 5s EE dE dua ER E ENER bk ek Ave
4. RAID firmware fails one of the mirrored disks it automatically replaces the failed disk with a hot spare disk and then resynchronizes the mirrored data The firmware automatically receives a notification when a hot spare replaces the failed disk and it then designates that disk as the new hot spare The OCE feature enables you to expand the capacity of an existing two disk Integrated Mirroring RAID 1 volume by replacing the original disk drives with higher capacity drives that have the same protocol SAS or SATA NOTE The new drives must have at least 50 GB more capacity than the original drives of the volume After you replace the disk drives and run the OCE command you must use a commercial tool specific to the operating system to move or increase the size of the partition on the volume The Integrated RAID firmware supports a background media verification feature that runs at regular intervals when the mirrored volume is in the Optimal state If the verification command fails for any reason the firmware reads the other disk s data for this segment and writes it to the failing disk in an attempt to refresh the data The firmware periodically writes the current media verification logical block address to nonvolatile memory so that the media verification can continue from where it stopped prior to a power cycle Page 11 Chapter 2 Overview of Integrated RAID Mirrored Volumes Mirrored Volume Features SAS2 Integrated RAID Solution U
5. Vista WinPE 2 1 Server 2008 Requires Windows driver v2 00 00 17 or greater UEFI 2 1 Linux 2 6 Kernel Red Hat Enterprise Linux RHEL 5 SUSE Linux Enterprise Server SLES 10 Requires Linux driver v00 255 04 00 or greater m MS DOS 6 22 and FreeDOS 1 0 SAS2IRCU runs on DOS only if the system BIOS supports 32 bit BIOS services including the PCI BIOS services SAS2IRCU uses these services to locate the controller and its interface registers because it must directly access the controller chip s interface registers Format commands as follows for the SAS2IRCU command line interface sas2ircu lt controller_ gt lt command gt lt parameters gt Use a space to separate the program name the controller number the command and the parameters fields The format of lt parameters gt is command specific Information passes between the user environment and the SAS2IRCU through the command line the standard output and standard error interfaces and the program return value You can redirect the output streams as permitted by the operating system When the program exits it returns a value of 0 if the command is successful Otherwise it returns a value of 1 If a RAID command fails the SAS2IRCU prints the IOC Status and OCLogInfo on the console You can use this information to analyze the cause of the failure The following table shows which commands the SAS2IRCU supports on each operating system Table 1 SASIRCU
6. a specific drive in a volume by turning on its location indicator and flashing its LED sas2ircu lt controller gt locate lt Enclosure Bay gt lt action gt m lt controller_ gt The index of the controller with the drives that you need to locate m lt Enclosure Bay gt The enclosure and bay number of the drive m lt action gt The possible actions are as follows ON Turn on the location indicator of the drive OFF Turn off the location indicator of the drive 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPTER_NOT_FOUND Cannot find specified adapter The LOGIR command uploads or clears the Integrated RAID log information sas2ircu lt controller gt logir lt action gt filename noprompt m lt controller_ gt The index of the controller with the logs that you need to upload or clear m lt action gt The possible actions are as follows UPLOAD Upload the controller logs to a file CLEAR Clear the controller logs filename This optional parameter specifies the filename where the logs must be uploaded The default filename is LOGIR LOG noprompt This optional parameter prevents warnings and prompts from appearing while the command is running 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPRTER NOT FOUND Cannot find specified
7. adapter Page 41 la Lei
8. an inactive volume This option is available only when the selected volume is currently inactive Follow these steps to activate a selected volume 1 In the Adapter List window use the arrow keys to select an LSI SAS adapter and press Enter The Adapter Properties window appears 2 Select RAID Properties and then press Enter The Select New Array Type window appears 3 Select View Existing Array The View Array window appears If necessary press Alt N to switch to another array on this adapter 4 Select Manage Array The Manage Array window appears 5 Select Activate Array on the Manage Array window A menu window appears 6 Press Y to activate the array The array becomes active after a pause 3 4 4 Deleting an Array CAUTION Before you delete an array be sure to back up all data on the array that you want to keep Follow these steps to delete a selected volume array 1 In the Adapter List window use the arrow keys to select an LSI SAS adapter The Adapter Properties window appears 2 Use the arrow keys to select RAID Properties and then press Enter The Select New Array Type window appears 3 Select View Existing Array The View Array window appears If necessary press Alt N to switch to another array on this adapter 4 Select Manage Array The Manage Array window appears 5 Select Delete Array A menu window appears 6 Either press Y to delete the array or press N to cancel the delet
9. and two 120 GB disks the volume uses only 100 GB on each of the 120 GB disks Refer to Chapter 2 Overview of Integrated RAID Mirrored Volumes for more information about the features of Integrated Mirroring Integrated Mirroring Striping and Integrated Mirroring Enhanced volumes The SAS2 BIOS CU is part of the Fusion MPT BIOS When the BIOS loads during the startup sequence and you see the message about the LSI Configuration Utility press Ctrl C to start the SAS2 BIOS CU After you do this the message changes to Please wait invoking SAS Configuration Utility After a brief pause the main menu Adapter List window of the SAS2 BIOS CU appears On some systems however the following message appears next LSI Corp Configuration Utility will load following initialization In this case the SAS2 BIOS CU loads after the system completes its power on self test You can configure one or two Integrated Mirroring Integrated Mirroring Striping and Integrated Mirroring Enhanced volumes on each LSI SAS2 controller You can also configure one mirrored volume and one Integrated Striping volume on the same controller up to a maximum of 14 disk drives for the two volumes This includes one or two optional hot spare disks for the mirrored volume s m All physical disks in a volume must be either SATA with extended command set support or SAS with SMART support You cannot combine SAS and SATA disks in the same volume However you can
10. controller The command does not change any other controller configuration parameters sas2ircu lt controller gt delete noprompt m lt controller_ gt The index of the controller with the volume s that you want to delete E noprompt This optional parameter prevents warnings and prompts from appearing while the command is running 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPRTER NOT FOUND Cannot find specified adapter The DISPLAY command displays information about LSI SAS2 controller configurations including controller type firmware version BIOS version volume information physical drive information and enclosure See the following Sample Output example The physical device information section displays the duplicate device of a dual port SAS drive sas2ircu lt controller gt display filename m lt controller_ gt The index of the controller for which you want to display information filename An optional valid filename to store the command output to a file 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPRTER NOT FOUND Cannot find specified adapter Page 35 Appendix A Commands Page 36 Sample Output SAS2 Integrated RAID Solution User Guide Following is a sample of the information that the DISPLAY command returns Read configuration
11. create one volume with SAS disks and a second volume with SATA disks on the same controller Page 13 Chapter 3 Creating Mirrored Volumes Creating Mirrored Volumes SAS2 Integrated RAID Solution User Guide m Disks must have 512 byte blocks and must not have removable media Integrated mirroring volumes must have two disks Integrated Mirroring Enhanced volumes can have three to ten disks and Integrated Mirroring Striping volumes can have an even number of disks ranging from four to ten disks NOTE LSI strongly recommends that you create global hot spare disks for all mirrored volumes to increase the level of data protection If a disk in a mirrored volume fails the Integrated RAID firmware rebuilds it using one of the global hot spares and the data is safe If you create two mirrored volumes on an LSI SAS 2 controller either of the two mirrored volumes can use the global hot spares if a disk fails 3 2 1 Creating an Integrated Mirroring Follow these steps to create a two disk Integrated Mirroring RAID 1 volume with the Volume SAS2 BIOS CU The steps begin with the Adapter List window that appears when the SAS2 BIOS CU starts 1 On the Adapter List window use the arrow keys to select an LSI SAS adapter and then press Enter The Adapter Properties window appears as the following figure shows LSI Corp Config Utility Adapter SAS2008 PCI Slot 02 PCI Address Bus Dev 06 04 MPT Firmware Revision XX XX xx xx IR SAS A
12. disk drives in a volume select the volume in the left column of the SAS Topology window and press Enter The LEDs flash on all disk drives in the volume until you press a key to stop them NOTE The LEDs on the disk drives flash as previously described if the firmware configuration is correct and the drives are in a disk enclosure You can select a boot disk in the SAS Topology window The next time you boot the computer the firmware moves this disk to scan ID 0 making it the new boot disk This makes it easier to set BIOS boot device options and to keep the boot device constant during device additions and removals You can also select an alternative boot device If the BIOS cannot find the preferred boot device when it loads it will attempt to boot from the alternate device Follow these steps to select a boot disk 1 In the SAS2 BIOS CU select an adapter from the Adapter List 2 Select the SAS Topology option If a device is currently designated as the boot device the Device Info column on the SAS Topology window lists the word Boot as shown in the following figure Page 21 Chapter 3 Creating Mirrored Volumes Other Configuration Tasks SAS2 Integrated RAID Solution User Guide Corp Config Utility SAS2008 06 00 Controller h Controller PHY 1 S SAS PHY 2 e Dis SAS SSD Expander I g q2 AO Expander PHY 1 F I SATA SSD PHY 2 si jis SATA SSD PHY 3 ne A SATA Alt PHY A P 3 SATA SSD Enclosure l Encl
13. menu to create the hot spare disk s The SAS2 BIOS CU pauses while it configures the global hot spares 3 3 2 Deleting Hot Spare Disks Follow these steps to delete a global hot spare disk 1 Access the Manage Hot Spares window by following steps 1 through 5 of the previous section Select a hot spare disk for deletion and press C Select Save changes then exit this menu to commit the changes The configuration utility pauses while it removes the global hot spare Page 18 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 3 4 Other Configuration Tasks 3 4 1 Viewing Volume Properties 3 4 2 Running a Consistency Check LSI Corporation Confidential August 2010 Chapter 3 Creating Mirrored Volumes Other Configuration Tasks This section explains how to perform other configuration and maintenance tasks for mirrored volumes Follow these steps to view the RAID properties of the mirrored volume s 1 In the SAS2 BIOS CU select an LSI SAS2 adapter from the Adapter List The Adapter Properties window appears 2 Select RAID Properties The Select New Array Type window appears 3 Select View Existing Array The View Array window appears showing information about the array and each disk in it The window includes global hot spare information if any exists NOTE If you create one volume using SAS disks another volume using SATA disks and one or two global hot spare disks the h
14. on the specified volume sas2ircu lt controller gt constchk lt volumeId gt noprompt m lt controller_ gt The index of the controller on which the consistency check operation will run E lt volumeId gt The volume ID of an Integrated RAID volume as listed in the DISPLAY command on which the consistency check operation will run noprompt This optional parameter prevents warnings and prompts from appearing while the command is running 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPTER_NOT_FOUND Cannot find specified adapter The ACTIVATE command activates an inactive Integrated RAID volume sas2ircu lt controller_ gt activate lt volumelId gt m lt controller_ gt The index of the controller with the volume that requires activation E lt volumeId gt The volume ID of an Integrated RAID volume currently in the Inactive state 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADARTER NOT FOUND Cannot find specified adapter LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide A 3 11 LOCATE Command Command Line Parameters Program Return Value A 3 12 LOGIR Command Command Line Parameters Program Return Value LSI Corporation Confidential August 2010 Appendix A Commands The LOCATE command locates
15. 3 Expanding an Integrated Mirroring Volume with OCE Page 16 4 Move the cursor to the RAID Disk column and select a line that has a No entry in this column which indicates that the disk is not already part of the volume you are creating To add the disk to the new array change the No to Yes by pressing the space bar CAUTION The SAS2 BIOS CU deletes all existing data from the disks drives when you select them to use for a mirrored volume 5 Move the cursor to another line and press the space bar to add another disk to the array If you select an odd number of disks the SAS2 BIOS CU creates an Integrated Mirroring Enhanced array If you select an even number of disks it creates an Integrated Mirroring Striping array As you add disks the Array Size field changes to reflect the size of the new array 6 Press C to create the array A menu window appears 7 From the menu options select Save changes then exit this menu A processing message appears briefly and then the SAS2 BIOS CU returns to the Adapter Properties window Initialization of the new array continues in the background NOTE To create a second Integrated Mirroring Enhanced or Integrated Mirroring Striping volume repeat the instructions above NOTE See the instructions in Section 3 3 Managing Hot Spare Disks if you want to create one or two global hot spares You can use the online capacity expansion OCE feature to expand the capacity of a two disk
16. Commands SAS2IRCU Operating System Command eg Ss CREATE D xX X 7 DELETE X X X 7 DISPLAY X X x 7 HOTSPARE X X X x LIST D X X 7 STATUS X X X X MFGPAGE X Z Z LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide A 3 1 Common Command Line Parameters A 3 2 CREATE Command LSI Corporation Confidential August 2010 Appendix A Commands Table 1 SASIRCU Commands Continued SAS2IRCU Operating System Command ET z CONSTCHK X X X x ACTIVATE X X X X LOCATE X X X 7 LOGIR X X X X The commands are not case sensitive The command descriptions use the following conventions Enter the text in italic exactly as shown on the command line Replace text enclosed in lt gt with a required parameter Replace text enclosed in with an optional parameter Enter parameters enclosed in one or more times as required for the command being executed Do not enter the command line definition characters lt gt and on the command line This section describes command line parameters that are common to more than one command m lt controller_ gt The unique controller number that the program assigns to each PCI function found on supported controller chips in the system starting with controller 0 For example in a system containing two LSISAS2008 controllers controller 0 references the first contro
17. Disk Drives in a VOIUME 6 cece cece nt E EEEE eet e eben een eee Ea 21 3 4 6 Selecting a BOOtDISK 208 ERENNERT EEN NEEN EE ERER EEN ts ae E deeg 21 Chapter 4 Overview of Integrated Striping 23 lge le EEN ER 42 Integrated Striping Features Ve gekee e d ENER AE EEN NNN E ebe EN dEN SEKERAN dd dE Ke ege EN ge EEN E date E ER 4 3 Integrated Striping Description 24 LSI Corporation Confidential August 2010 Page 3 Table of Contents SAS2 Integrated RAID Solution User Guide Chapter 5 Creating Integrated Striping Volumes 6 cece cece een e nen e ened ence etn e ened bene ete n teenie eneees 25 5 1 Integrated Striping Configuration Overview 25 5 2 Creating Integrated Striping Volumes 25 5 3 Other Configuration Tasks siitcxia s aaccenccceie tae a Elie ENT ENEE ENEE SREL EE 27 5 3 1 Viewing Volume Properties nsss eners H SNE ating rhel ERR SNE EEN SEENEN Eeer Sei ENN NNN AER deer ER KE dE le EI CEET ER 5 3 3 Deletingan Array ereire Bean ENEE EEN ENEE EE EE Ae 28 5 3 4 Locating Disk Drives in a Volume 28 5 3 5 Selecting a Bot Disk i235 Geet SNE re ele baddest SNE Aen SET EEN eech NN Aen erte 29 Appendix A Using the SAS2 Integrated RAID Configuration Utility Lunner cee cent e ene e nent ne en een eneees 31 A 1 Hardware and Software Requirements ccc cece cece ee eee nn ne nen ene n EEE EEE EERE R ER EEE EEE EEE EERE E EE EE EE SEES GES 31 ALA Controller SUpport oeiee nonae ee S
18. I Integrated RAID solution includes the following RAID features The Integrated Mirroring solution which provides features of RAID 1 The Integrated Mirroring Striping solution which provides features of RAID 10 The Integrated Mirroring Enhanced solution which provides features of RAID 1 Enhanced RAID 1E The Integrated Striping solution which provides features of RAID 0 By simplifying the configuration options and by providing firmware support in its SAS2 host adapters LSI can offer the Integrated RAID solution at a lower cost than a hardware RAID implementation LSI Fusion MPT firmware supports Integrated Mirroring volumes Integrated Mirroring Striping volumes Integrated Mirroring Enhanced volumes and Integrated Striping volumes You can create up to two Integrated RAID volumes on each LSI SAS2 controller The LSI Integrated RAID solution supports the following LSI SAS2 controllers and the host bus adapters based on these controllers LSISAS2004 LSISAS2008 LSISAS2108 LSISAS2208 LSISAS2304 LSISAS2308 LSI Integrated RAID firmware uses the same device drivers as the standard LSI Fusion MPT based controllers This eliminates the need for complex backup software or expensive RAID hardware To conserve system resources the Integrated RAID firmware operates independently from the operating system The BIOS based configuration utility documented in Chapter 3 and Chapter 5 makes it easy to configure mirrored and stri
19. Integrated Mirroring RAID 1 volume by replacing the original disks with two higher capacity disk drives while the volume remains online This process maintains data integrity at all times even if one of the disks fails during the replacement process The new disks must have at least 50 GB more capacity than the disks they are replacing and they must use the same protocol SAS or SATA as the disks they are replacing Follow these steps to expand an existing RAID1 volume with OCE 1 Physically replace one of the two volume disk drives with a drive that has at least 50 GB more capacity If necessary you can identify the disks in the volume by following the instructions in Section 3 4 5 Locating Disk Drives ina Volume 2 Wait until synchronization completes on the new disk and the volume returns to the Optimal state as indicated in the Adapter Properties window of the SAS2 BIOS CU 3 Physically replace the other volume disk drive with a drive that has at least 50 GB more capacity LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 3 3 Managing Hot Spare Disks 3 3 1 Creating Hot Spare Disks LSI Corporation Confidential August 2010 10 11 Chapter 3 Creating Mirrored Volumes Managing Hot Spare Disks Again wait until synchronization completes on the new disk and the volume returns to the Optimal state In the Adapter List window of the SAS2 BIOS CU use the arrow keys to selec
20. S status LED support for drives used in Integrated Striping volumes LSI Corporation Confidential August 2010 Page 23 Chapter 4 Overview of Integrated Striping Integrated Striping Description 4 3 Integrated Striping Description Page 24 SAS2 Integrated RAID Solution User Guide On Integrated Striping volumes the firmware writes data across multiple disks instead of onto one disk It does this by partitioning each disk s storage space into 64 KB stripes The firmware interleaves the stripes round robin so that the combined storage space consists alternately of stripes from each disk The following figure shows an example of integrated striping the firmware writes segment 1 to disk 1 segment 2 to disk 2 segment 3 to disk 3 and so on When the firmware reaches the end of the disk list it continues writing data at the next available segment of disk 1 LSI SAS2 Controller Segment 1 Segment 2 Segment 3 Segment 4 Segment 5 Segment 6 Segment 7 Segment 8 Segment 9 Segment 10 Segment 11 Segment 12 3_00010 00 Figure 8 Integrated Striping Example The following figure shows a logical view and a physical view of an Integrated Striping volume with three disks Logical View Physical View Stripe 8 3_00011 00 Figure 9 Integrated Striping Logical and Physical Views Speed is the primary advantage of the Integrated Striping solution because it transfers data to or from multiple disks simultaneously Howev
21. S2 Integrated RAID Solution User Guide m Disks must have 512 byte blocks and must not have removable media m Integrated Striping volumes must have at least two disks and no more than 10 disks Integrated Striping volumes do not support hot spare disks Follow these steps to configure an Integrated Striping volume with the SAS2 BIOS CU after The steps begin with the Adapter List window that appears when the SAS2 BIOS CU starts 1 On the Adapter List window select an LSI SAS adapter and press Enter The Adapter Properties window appears as the following figure shows LSI Corp Config Utility Adapter SAS2008 PCI Slot 02 PCI Address Bus Dev 06 04 MPT Firmware Revision XX XX XX XX IR SAS Address XXXXXXXX XXXXXXXX NVDATA Version XX XX Status Enabled Boot Order X Boot Support E Help Figure 10 Adapter Properties Window 2 Select RAID Properties and press Enter The Create Array window appears 3 Select Create RAID 0 Volume The Create New Array window appears 4 Move the cursor to the RAID Disk column and select a line that has a No entry in this column which indicates that the disk is not already part of the volume you are creating To add the disk to the new array change the No to Yes by pressing the space bar 5 Move the cursor to another line and press the space bar to add another disk to the array Continue adding disks in this way until you have added the desired number of disks 7 Press C t
22. ddress XXXXXXXX XXXXXXXX NVDATA Version XX XX Status Enabled Boot Order X Boot Support F Figure 5 Adapter Properties Window 2 Use the arrow keys to select RAID Properties and then press Enter The Create Array window appears 3 Select Create RAID 1 Volume The Create New Array window appears Page 14 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 3 2 2 Creating an Integrated Mirroring Enhanced or Integrated Mirroring Striping Volume LSI Corporation Confidential August 2010 Chapter 3 Creating Mirrored Volumes Creating Mirrored Volumes 4 Move the cursor to the RAID Disk column and select a line that has a No entry in this column indicating that the disk is not already part of the volume you are creating To add the disk to the new array change the No to Yes by pressing the space bar This is the Primary disk in the array CAUTION The SAS2 BIOS CU deletes all existing data from the disks drives when you select them to use in a mirrored volume 5 Move the cursor to another line and press the space bar to add the second disk to the array This is the Secondary disk in the array 6 Press C to create the array A menu window appears 7 From the menu options select Save changes then exit this menu A processing message appears briefly and then the SAS2 BIOS CU returns to the Adapter Properties window Initialization of the new array continues in the backgrou
23. designated as the alternate boot device the Device Info column shows the word Alt 3 To select the preferred boot disk move the cursor to the disk and press Alt B To remove the boot designator move the cursor to the current boot disk and press Alt B This controller no longer has a disk designated as boot 5 To change the boot disk move the cursor to the new boot disk and press Alt B The Boot designator moves to this disk LSI Corporation Confidential August 2010 Page 29 Chapter 5 Creating Integrated Striping Volumes Other Configuration Tasks SAS2 Integrated RAID Solution User Guide 6 To select an alternate boot disk move the cursor to the disk and press Alt A NOTE To change the alternate boot device from one disk to another follow steps 4 and 5 in this procedure but use Alt A instead of Alt B Page 30 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Appendix A Appendix A Hardware and Software Requirements Using the SAS2 Integrated RAID Configuration Utility This appendix explains how to use the command line driven SAS2 Integrated RAID configuration utility SAS2IRCU to create Integrated RAID volumes on LSI SAS2 controllers in the manufacturing environment A 1 Hardware and Software Requirements A 1 1 Controller Support LSI Corporation Confidential August 2010 SAS2IRCU is a command line utility that you can use to configure the Int
24. eatures This section describes features of Integrated Mirroring Integrated Mirroring Striping and Integrated Mirroring Enhanced volumes You can configure one or two mirrored volumes on each LSI SAS2 controller The Integrated RAID firmware allows host I O transactions to continue on a mirrored volume while it resynchronizes the volume in the background The firmware automatically starts resynchronizing data after a disk failure activates a hot spare or after a disk in a mirrored volume has been hot swapped The Integrated RAID firmware supports hot swapping and it automatically resynchronizes the hot swapped disk in the background without any host or user intervention The firmware detects hot swap removal and disk insertion Following a hot swap event the firmware verifies that the new physical disk has enough capacity for the mirrored volume The firmware resynchronizes all replaced hot swapped disks even if the same disk is re inserted In a mirrored volume with an even number of disks the firmware marks the hot swapped disk as a secondary disk and the other disk with data as the primary disk The firmware resynchronizes all data from the primary disk onto the new secondary disk In a mirrored volume with an odd number of disks primary and secondary sets include three disks instead of two You can configure two disks as global hot spare disks to protect data on the mirrored volumes configured on the SAS2 controller If the Integrated
25. eed deelt et bech ges AA Deeg E Ehe elt dE 31 A 1 2 Operating System and Software Support 32 A2 Interface Description a eege Beet EE eech pam me aes meen AE eege EE e SERA ett ER Ee EE 32 A 3 1 Common Command Line Parameters 00 c ccc cee een n ener n nent ened enced eee e ents been eeneeee 33 A 3 2 CREATE eu EE 33 A33 DELETE COMMANA ae e Dee ee A Ae EA enpaibew ney dae a ited setae EE 35 A 3 4 DISPLAY Command Zeen bade age tok seek beatae Gee Mas ioe ee eee 35 A3 5 HOTSPARE Commanid EE 37 A 3 6 STATUS Command EE 38 A237 LIST Command EE 39 A 3 8 MFGPAGE Command Aa EEN ated o e ERENNERT ade ee Rea 40 A3 9 CONSTCHK COMMANA Kasis cad dees hees deg dee dr E EE ee obama SES ang 40 A3A0 ACTIVATE COmMANG ieee nes ice ake cate E ER de EEN a a ae eae AA Soe Sea ee ce ee 40 A3 MI LOCATE Commando EE 41 A312 LOGIR Command BEER 41 Page 4 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 1 Chapter 1 Introduction to the Integrated RAID Solution Overview Introduction to the Integrated RAID Solution This chapter provides an introduction to the features and benefits of the LSI Integrated RAID solution for LSI SAS2 controllers 1 1 Overview LSI Corporation Confidential August 2010 The LSI Integrated RAID solution provides cost benefits for the server or workstation market that requires the extra performance storage capacity and or redundancy of a RAID configuration The LS
26. een the SAS2 controller and the devices that connect to it The Fusion MPT drivers for all supported operating systems implement the Fusion MPT interface to communicate with the controller and firmware Page 6 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 2 Chapter 2 Overview of Integrated RAID Mirrored Volumes Introduction Overview of Integrated RAID Mirrored Volumes This chapter provides an overview of the LSI Integrated RAID features that support the creation of mirrored arrays 2 1 Introduction 2 2 Integrated Mirroring and Integrated Mirroring Enhanced Features LSI Corporation Confidential August 2010 As a result of the shift towards network attached storage NAS Internet service providers need a cost effective fault tolerant solution to protect the operating systems on small form factor high density rack mountable servers The mirroring features of the LSI Integrated RAID solution provide data protection for the system boot volume which safeguards the operating system and other critical information on servers and high performance workstations The Integrated RAID solution supports the following types of mirrored arrays The Integrated Mirroring solution which provides features of RAID 1 m The Integrated Mirroring Striping solution which provides features of RAID 10 The Integrated Mirroring Enhanced solution which provides features of RAID 1 En
27. egrated RAID functions of LSI SAS2 controllers SAS2IRCU is a minimally interactive program that you can execute from a command line prompt or a shell script When you use a SAS2IRCU command the program returns a status value to the operating system when it exits OEMs can use SAS2IRCU to configure Integrated RAID devices on the LSI family of MPT2 0 based SAS2 controllers You typically use this utility for system configuration on the manufacturing floor NOTE End users should not use the SAS2IRCU utility Instead they should use the LSI SAS2 BIOS Configuration Utility SAS2 BIOS CU to create and manage Integrated RAID volumes For more information see Chapter 3 and Chapter 5 SAS2IRCU runs on the following platforms X86 or X64 compatible m United Extensible Firmware Interface UEFI 2 m EM64T AMD64 m Sun SPARC v9 SAS2IRCU works with storage devices that are compliant with existing SCSI standards SAS2IRCU supports the following LSI SAS2 controllers and the host bus adapters based on these controllers LSISAS2004 LSISAS2008 LSISAS2108 LSISAS2208 LSISAS2304 LSISAS2308 Page 31 Appendix A Interface Description A 1 2 Operating System and Software Support A 2 Interface Description A 3 Commands Page 32 SAS2 Integrated RAID Solution User Guide SAS2IRCU requires PCI 2 x or PCI 3 0 firmware and MPI v2 0 SAS2IRCU supports the following operating systems m WinPE 1 x Server 2003 XP WinPE 2 0
28. er there is no data redundancy Back the data up on other media to avoid losing unsaved data if one disk fails LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 5 Chapter 5 Creating Integrated Striping Volumes Integrated Striping Configuration Over Creating Integrated Striping Volumes This chapter explains how to create Integrated Striping volumes using the LSI SAS2 BIOS Configuration Utility SAS2 BIOS CU 5 1 Integrated Striping Configuration Overview 5 2 Creating Integrated Striping Volumes LSI Corporation Confidential August 2010 The LSI SAS2 BIOS CU is a menu driven utility program that enables you to easily configure and manage Integrated RAID volumes You can use the SAS2 BIOS CU to create one or two Integrated Striping volumes on each LSI SAS2 controller Each volume can have from two to ten drives All disks in an Integrated Striping volume must be connected to the same LSI SAS2 controller Although you can use disks of different size in Integrated Striping volumes the smallest disk in the volume determines the logical size of all disks in the volume In other words the firmware does not use the excess space of the higher capacity member disk s For example if you create an Integrated Striping volume with two 100 GB disks and two 120 GB disks the firmware uses only 100 GB on each of the 120 MB disks for the volume The supported stripe size is 64 kilobytes
29. f the initialization Observe the following rules when creating Integrated RAID volumes and hot spare disks Alldisks that are part of a volume including hot spares for that volume must be on the same SAS2 controller m You can create RAID 0 RAID 1 RAID 1E and RAID 10 Integrated RAID volumes m You can create a maximum of two Integrated RAID volumes per controller m The configuration of the Integrated RAID firmware determines the maximum and minimum number of drives that you can use in Integrated RAID volumes The following fields of IOC Page 6 specify the configuration MaxDrivesRAIDO MaxDrivesRAID1 MaxDrivesRAID10 MaxDrivesRAID1E MinDrivesRAIDO MinDrivesRAID1 MinDrivesRAID10 MinDrivesRAID1E MaxVolumes MaxPhysDisks MaxGlobalHotSpares MaxPhysDisks maximum number of physical drives combined in all volumes on the controller For more information refer to the description of the IOC configuration pages in the Fusion MPT 2 0 MPI Specification Guide m SAS2IRCU does not allow you to create an Integrated RAID volume that combines SAS and SATA hard disk drives m SAS2IRCU does not allow you to create an Integrated RAID volume that combines SSDs solid state drives and hard disk drives m SAS2IRCU does allow you to use both SATA and SAS solid state drives in a single Integrated RAID volume if the Integrated RAID firmware supports it Support for such a mixing is specified by values in static fields in Manufacturing Page 4
30. hanced RAID 1E These three mirroring solutions provide a robust high performance fault tolerant solution to data storage needs at a lower cost than a dedicated RAID controller Mirrored volumes may have from two to ten disks to provide fault tolerant protection for critical data Mirrored volumes also support one or two global hot spare drives with a maximum of 14 drives on each LSI SAS2 controller NOTE Fourteen drives is the theoretical upper limit for a single LSI SAS2 controller although the controller itself may support fewer than 14 drives You can also configure one mirrored volume and one Integrated Striping volume on the same LSI SAS controller Each SAS2 controller can have two global hot spare disks available to automatically replace a failed disk in the one or two mirrored volumes configured on the controller The hot spares make the mirrored volumes even more fault tolerant Integrated Mirroring Integrated Mirroring Striping and Integrated Mirroring Enhanced volumes support the following features Configurations of one or two mirrored volumes on each LSI SAS2 controller Each volume can consist of two mirrored disks for an Integrated Mirroring volume three to ten mirrored disks for an Integrated Mirroring Enhanced volume or four six eight or ten mirrored disks for an Integrated Mirroring Striping volume Optional Two global hot spare disks per LSI SAS2 controller to automatically replace failed disks in mi
31. has been initiated for controller 0 Controller type BIOS version Firmware version Channel description SCSI Initiator ID Maximum physical devices Concurrent commands supported Slot Segment Bus Device Function RAID Support Physical device information Initiator at ID 112 Device at ID 335524 Device is a Hard disk Enclosure Slot Connector ID State Size in MB in sectors Manufacturer Model Number Firmware Revision Serial No Protocol Drive Type Enclosure Logical ID Numslots StartSlot SAS2008 7 00 02 00 00 250 19 0 1 Serial Attached dE 62 266 3 0 64 2 2 4 Ready RDY 70007 143374738 HP DGO72A9BB7 HPDO B365P720H7330709 SAS SAS 51234567 89012345 8 0 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide A 3 5 HOTSPARE Command LSI Corporation Confidential August 2010 Appendix A Commands Logical drive status values are as follows Okay OKY The volume is active and drives are functioning properly User data is protected if the current RAID level provides data protection Degraded DGD The volume is active User data is not fully protected because the configuration has changed or a drive has failed Failed FLD The volume has failed Missing MIS The volume is missing Initializing INIT The volume is initializing Online ONL The volume is online Physical device status values are as follow
32. in the MPI2 specification and is specific for SSD drives only sas2ircu lt controller gt create lt volume_type gt lt size gt lt Enclosure Bay gt VolumeName noprompt m lt controller_ gt The index of the controller for the newly created volume m lt volume_type gt Volume type for the new volume Valid values are RAIDO RAID1 RAID10 or RAID1E m lt size gt Size of the RAID volume in Mbytes or MAX for the maximum size available E lt Enclosure Bay gt The Enclosure Bay value of the disk drive for the new RAID volume You can get these values from the output of the DISPLAY command DOS does not support addressing by Enclosure Bay E VolumeName A user specified string to identify the volume noprompt This optional parameter prevents warnings and prompts from appearing while the command is running LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Program Return Value A 3 3 DELETE Command Command Line Parameters Program Return Value A 3 4 DISPLAY Command Command Line Parameters Program Return Value LSI Corporation Confidential August 2010 Appendix A Commands 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPTER_NOT_FOUND Cannot find specified adapter The DELETE command deletes all of the Integrated RAID volumes and hot spare drives from the specified LSI SAS2
33. ion process Page 20 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 3 4 5 Locating Disk Drives in a Volume 3 4 6 Selecting a Boot Disk LSI Corporation Confidential August 2010 Chapter 3 Creating Mirrored Volumes Other Configuration Tasks After a pause the utility deletes the array If there is another remaining array and one or two hot spare disks the BIOS checks the hot spare disks to determine if they are compatible with the remaining volume If they are not compatible too small or wrong disk type the BIOS deletes them also You can use the SAS2 BIOS CU to locate and identify a specific physical disk drive in a disk enclosure by flashing the drive s LED You can also flash the LEDs of all the disk drives in a RAID volume if they are in a disk enclosure When you add a disk drive to a new mirrored volume the LED on the disk drive starts flashing The LED stops flashing when you finish creating the volume You can locate individual disk drives from the SAS Topology window by flashing their LEDs To do this follow these steps 1 Select the desired SAS2 controller on the Adapter List window and press Enter The Adapter Properties window appears 2 Highlight SAS Topology and press Enter The SAS Topology window appears 3 Select the disk in the Device Identifier column and press Enter The LED on the disk flashes until you press a key to stop it 4 To identify all the
34. ivate Array option allows you to reactivate an inactive volume This option is available only when the selected volume is currently inactive Follow these steps to activate a selected volume 1 In the Adapter List window use the arrow keys to select an LSI SAS adapter and press Enter The Adapter Properties window appears 2 Select RAID Properties and then press Enter The Select New Array Type window appears 3 Select View Existing Array The View Array window appears If necessary press Alt N to switch to another array on this adapter 4 Select Manage Array The Manage Array window appears 5 Select Activate Array on the Manage Array window A menu window appears Page 27 Chapter 5 Creating Integrated Striping Volumes Other Configuration Tasks SAS2 Integrated RAID Solution User Guide 5 3 3 Deleting an Array 5 3 4 Locating Disk Drives in a Volume Page 28 6 Press Y to activate the array The array becomes active after a pause CAUTION Before you delete an array be sure to back up the data Follow these steps to delete a selected volume array 1 In the Adapter List window use the arrow keys to select an LSI SAS adapter The Adapter Properties window appears Use the arrow keys to select RAID Properties and then press Enter The Select New Array Type window appears Select View Existing Array The View Array window appears If necessary press Alt N to switch to anothe
35. l Lei SAS2 Integrated RAID Solution User Guide Version 2 0 August 2010 Revision History Version and Date Description of Changes Version 2 0 August 2010 Added new models of supported controllers Version 1 1 August 2009 Applied extensive general editing improvements Version 1 0 July 2009 Initial release of this document LSI the LSI logo Fusion MPT are trademarks or registered trademarks of LSI Corporation or its subsidiaries All other brand and product names may be trademarks of their respective companies LSI Corporation reserves the right to make changes to the product s or information disclosed herein at any time without notice LSI Corporation does not assume any responsibility or liability arising out of the application or use of any product or service described herein except as expressly agreed to in writing by LSI Corporation nor does the purchase lease or use of a product or service from LSI Corporation convey a license under any patent rights copyrights trademark rights or any other of the intellectual property rights of LSI Corporation or of third parties This document contains proprietary information of LSI Corporation The information contained herein is not to be used by or disclosed to third parties without the express written permission of LSI Corporation Corporate Headquarters Email Website Milpitas CA globalsupport lsi com www lsi com 800 372 2447 Document Number DB15 000543 02
36. lity 1 2 1 Host Interface The Integrated RAID host interface uses the message passing interface as described in the Fusion MPT Message Passing Interface Specification The Fusion MPT interface gives the host OS access to the RAID volumes as well as to additional non RAID physical disks 1 2 2 Metadata Support The Integrated RAID firmware supports metadata which describes the logical drive configuration stored on each member disk of a volume After initialization the firmware queries each member disk to read the metadata and verify the configuration The firmware reduces the usable disk space for each member disk when it creates the the volume which makes room for the metadata 1 2 3 SMART Support The Self Monitoring Analysis and Reporting Technology SMART monitors disk drives for signs of future disk failure and generates an alert if it detects such signs The Integrated RAID firmware polls each physical disk in the volume at regular intervals If the firmware detects a SMART ASC ASCQ code on a physical disk in the volume it processes the SMART data and stores it in a log The volume does not support SMART directly because it is only a logical representation of the physical disks in the volume 1 2 4 Fusion MPT Support The Integrated RAID BIOS uses the LSI Fusion MPT interface to communicate to the SAS2 controller and firmware This process includes reading the Fusion MPT configuration to access the parameters that define behavior betw
37. ller and controller 1 references the other controller Valid controller number values are 0 to 255 decimal E lt Enclosure Bay gt The enclosure and bay slot of a peripheral device attached to the bus The argument must use a colon as a separator and must follow the enclosure bay format Enclosure is a 16 bit EnclosureHandle value set by the I O controller IOC A value of 0 is invalid Bay Slot is a 16 bit slot value set by the IOC Use the DISPLAY command to get the enclosure and slot numbers of a drive The CREATE command creates Integrated RAID volumes on LSI SAS2 controllers When you add a disk to an Integrated RAID volume the volume might not use all of the disk s storage capacity For example if you add a 300 GB disk drive to a volume that only uses 200 GB of capacity on each disk drive the volume does not use the remaining 100 GB of capacity on the disk drive Page 33 Appendix A Commands Page 34 Command Line Parameters SAS2 Integrated RAID Solution User Guide The disk identified by the first Enclosure Bay on the command line becomes the primary disk drive when you create an Integrated Mirroring RAID 1 volume If the controller resynchronizes the disk drives the data on the primary disk drive becomes available when you access the newly created volume When the IR firmware creates a RAID 1 volume it starts a background initialization of the volume You can use the STATUS command to monitor the status o
38. lumes Other Configuration Tasks NOTE The LEDs on the disk drives flash as previously described if the firmware configuration is correct and the drives are in a disk enclosure 5 3 5 Selecting a Boot Disk You can select a boot disk in the SAS Topology window The next time you boot the computer the firmware moves this disk to scan ID 0 making it the new boot disk This makes it easier to set BIOS boot device options and to keep the boot device constant during device additions and removals You can also select an alternative boot device If the BIOS cannot find the preferred boot device when it loads it attempts to boot from the alternate device Follow these steps to select a boot disk 1 In the SAS2 BIOS CU select an adapter from the Adapter List 2 Select the SAS Topology option If a device is currently designated as the boot device the Device Info column on the SAS Topology window lists the word Boot as the following figure shows LSI Corp Config Utility SAS2008 06 00 Controller Controller PHY 1 SAS PHY 2 N SAS SSD Expander J Expander PHY 1 R SATA SSD PHY 2 RA SATA SSD PHY 3 SATA Alt PHY A sical SATA SSD Enclosure Enclosure l SLOTO SATA l SLOT 6 SATA l SLOT 7 SATA IR VOL i ban PHY 1 Some Disk Model Y RAID PHY 2 Some Disk Model Y RAID PHY A Some Disk Model X Hot Spare Alt M More Figure 11 Boot Device on SAS Topology Window If a device is currently
39. mand returns when a volume resynchronization is in progress Background command progress status for controller 0 IR Volume 1 Volume ID 6 Current operation Synchronize Volume status Enabled Volume state Degraded Physical disk I Os Not quiesced Volume size in sectors 70311936 Number of remaining sectors 68250624 Percentage complete 2 93 Following is an example of the status information that the STATUS command returns if a background volume operation is not in progress Background command progress status for controller 0 IR Volume 1 Current operation None Volume ID 6 Volume status Enabled Volume state Optimal Physical disk I Os Not quiesced The possible values for the fields in the status data are as follows Current operation Synchronize Consistency Check OCE Background Init or None Volume status Enabled or Disabled Volume state Inactive Optimal Degraded Missing or Failed Physical disk I Os Quiesced or Not quiesced The LIST command displays a listing of all controllers present in system along with each corresponding controller index You use the controller index as an input parameter for other SAS2IRCU commands sas2ircu list None 0x00 SUCCESS Command completed successfully 0x01 FAILURE Command failed 0x02 ADARTER NOT FOUND Cannot find specified adapter Following is an example of the output of the LIST command The format and fields in the output may vary depending on the
40. mirrored stripe to a disk and mirrors it to an adjacent disk RAID 10 is another term for this type of mirrored striped configuration Logical View Physical View Mirrored Stripe 1 Mirrored Stripe 1 Mirrored Stripe 1 Mirrored Stripe 2 Mirrored Stripe 2 Mirrored Stripe 2 Mirrored Stripe 3 Mirrored Stripe 3 Mirrored Stripe 4 Mirrored Stripe 4 Mirrored Stripe 3 cy Mirrored Stripe 5 A Mirrored Stripe 5 Mirrored Stripe 6 f A Mirrored Stripe 6 Mirrored Stripe 4 Mirrored Stripe 7 Mirrored Stripe 7 Mirrored Stripe 8 Mirrored Stripe 8 Mirrored Stripe N Mirrored Stripe N 1 Mirrored Stripe N 1 Mirrored Stripe N Mirrored Stripe N 3_00009 00 Figure 4 Integrated Mirroring Striping with Four Disks The LSI SAS2 BIOS configuration utility enables you to create mirrored volumes during initial setup and to reconfigure them in response to hardware failures or changes in the environment CAUTION The SAS2 BIOS CU deletes all existing data from the disks drives when you select them to use for a mirrored volume Page 10 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 2 4 Mirrored Volume Features 2 4 1 Resynchronization with Concurrent Host I O Operation 2 4 2 Hot Swapping 2 4 3 Hot Spare Disk 2 4 4 Online Capacity Expansion 2 4 5 Media Verification LSI Corporation Confidential August 2010 Chapter 2 Overview of Integrated RAID Mirrored Volumes Mirrored Volume F
41. nd NOTE To create a second Integrated Mirroring volume repeat these instructions starting with step 2 Alternatively follow the instructions in the following section to create an Integrated Mirroring Enhanced or Integrated Mirroring Striping volume NOTE See the instructions in Section 3 3 Managing Hot Spare Disks if you want to create one or two global hot spares Integrated Mirroring Enhanced volumes can have from three to ten physical disks Data is written to a disk and mirrored on an adjacent disk Integrated Mirroring Striping volumes can have a minimum of four and a maximum of 10 physical disks in even numbers In an Integrated Mirroring Enhanced or Integrated Mirroring Striping volume the data is both mirrored and striped Follow these steps to create an Integrated Mirroring Enhanced RAID 1E or Integrated Mirroring Striping RAID 10 volume with the SAS2 BIOS CU The steps begin with the Adapter List window that appears when the configuration utility starts 1 On the Adapter List window use the arrow keys to select an LSI SAS adapter and then press Enter The Adapter Properties window appears as shown in Figure 5 2 Use the arrow keys to select RAID Properties and then press Enter The Create Array window appears 3 Select Create RAID 1E Volume The Create New Array window appears Page 15 Chapter 3 Creating Mirrored Volumes Creating Mirrored Volumes SAS2 Integrated RAID Solution User Guide 3 2
42. nd when you move a redundant volume from one SAS controller to another SAS controller MDC compares the data on the primary and secondary disks If MDC finds inconsistencies it copies data from the primary disk to the secondary disk Page 12 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 3 Chapter 3 Creating Mirrored Volumes Mirrored Volume Configuration Overview Creating Mirrored Volumes This chapter explains how to create Integrated Mirroring Integrated Mirroring Striping and Integrated Mirroring Enhanced volumes with the LSI SAS2 BIOS Configuration Utility SAS2 BIOS CU 3 1 Mirrored Volume Configuration Overview 3 2 Creating Mirrored Volumes LSI Corporation Confidential August 2010 The LSI SAS2 BIOS CU is a menu driven utility program that enables you to easily configure and manage Integrated RAID volumes You can use the SAS2 BIOS CU to create one or two mirrored volumes on each LSI SAS2 controller with up to two optional global hot spare disks You must connect all disks in a mirrored volume to the same LSI SAS2 controller Although you can use disks of different size in mirrored volumes the smallest disk in the volume determines the logical size of all disks in the volume In other words the volume does not use the excess space of the higher capacity member disk s For example if you create an Integrated Mirroring Enhanced volume with two 100 GB disks
43. ng feature has many of the advantages of a more expensive RAID striping solution You can configure an Integrated Striping volume as the boot disk or as a data disk The Integrated Striping solution provides better performance and more capacity than individual disks without burdening the host CPU The firmware distributes host I O transactions over multiple disks and presents the disks as a single logical drive In general striping is transparent to the BIOS the drivers and the operating system You can use the LSI SAS2 BIOS CU to configure Integrated Striping volumes These volumes can consist of two to ten disks 4 2 Integrated Striping Features Integrated Striping supports the following features Support for volumes with two to ten disks Support for two Integrated Striping volumes with up to 14 drives total on a SAS2 controller Support for combining one Integrated Striping volume and one Integrated Mirroring Integrated Mirroring Striping or Integrated Mirroring Enhanced volume on a single controller Support for both SAS and SATA drives although you cannot combine the two types of drives in one volume Fusion MPT architecture Easy to use SAS BIOS configuration utility Error notification Disk write caching which is enabled by default on all Integrated Striping volumes Use of metadata to store volume configurations on disks OS specific event log Error display inside the Fusion MPT BIOS SCSI Enclosure Services SE
44. ntroller_ gt The index of the controller on which you want to create the hot spare disk m lt Enclosure Bay gt The Enclosure Bay value for the hot spare disk drive You can get these values from the output of the DISPLAY command DOS does not support addressing by Enclosure Bay m delete This optional command deletes the hot spare disk at enclosure bay 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADARTER NOT FOUND Cannot find specified adapter The STATUS command displays the current status of any existing Integrated RAID volumes and the status of any operation that is currently in progress on the selected controller If an operation is not in progress the SAS2IRCU prints a message indicating this condition before it exits sasZircu lt controller gt status m lt controller_ gt The index of the controller with the volumes whose status you want to display 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPTER_NOT_FOUND Cannot find specified adapter LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide A 3 7 LIST Command Sample Output Command Line Parameters Program Return Value LSI Corporation Confidential Sample Output August 2010 Appendix A Commands Following is an example of the information that the STATUS com
45. o create the array A menu appears Page 26 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide 5 3 Other Configuration Tasks 5 3 1 Viewing Volume Properties 5 3 2 Activating an Array LSI Corporation Confidential August 2010 Chapter 5 Creating Integrated Striping Volumes Other Configuration Tasks 8 From the menu options select Save changes then exit this menu A Processing message appears briefly and then the SAS2 BIOS CU returns to the Adapter Properties window Initialization of the new array continues in the background NOTE Repeat the previous instructions to create a second Integrated Striping volume if desired and if enough additional disks are available This section explains how to perform other configuration and maintenance tasks for Integrated Striping volumes Follow these steps to view the RAID properties of a volume 1 In the SAS2 BIOS CU select an LSI SAS2 adapter from the Adapter List The Adapter Properties window appears 2 Select RAID Properties The Select New Array Type window appears 3 Select View Existing Array The View Array window appears showing information about the array and each disk in it 4 Ifthe currently displayed array is not the one you want press Alt N to view another array on the adapter A volume array can become inactive if for example you remove it from one controller or computer and install it on a different one The Act
46. osure l SLOTO SATA l SLOT Some Di SATA l SLOT 7 SATA IR VOL I Boot PHY 1 Some Disk Model Y RAID PHY 2 Some Disk Model Y PHY A Some Disk Model X AlttM k Figure 7 Boot Device on SAS Topology Window If a device is currently designated as the alternate boot device the Device Info column shows the word Alt 3 To select the preferred boot disk move the cursor to the disk and press Alt B To remove the boot designator move the cursor to the current boot disk and press Alt B This controller no longer has a disk designated as boot 5 To change the boot disk move the cursor to the new boot disk and press Alt B The Boot designator moves to this disk 6 To select an alternate boot disk move the cursor to the disk and press Alt A NOTE To change the alternate boot device from one disk to another follow steps 4 and 5 but use Alt A instead of Alt B Page 22 LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 4 Overview of Integrated Striping Introduction Chapter 4 Overview of Integrated Striping This chapter provides an overview of the LSI Integrated RAID features that support the creation of striped arrays 4 1 Introduction The LSI Integrated RAID solution enables you to create Integrated Striping volumes for TTT ap plications that require the faster performance and increased storage capacity of striping The low cost Integrated Stripi
47. ot spare disks only appear when you view the mirrored volume that uses the same type of disks as the hot spare disks 4 If the currently displayed array is not the one you want press Alt N to view another array on the adapter Use the Consistency Check command to verify that the data is synchronized on the mirrored disks in the volume Follow these steps to run a consistency check on a selected mirrored volume 1 In the Adapter List window use the arrow keys to select an LSI SAS adapter The Adapter Properties window appears 2 Use the arrow keys to select RAID Properties and then press Enter The Select New Array Type window appears 3 Select View Existing Array The View Array window appears If necessary press Alt N to switch to another array on this adapter 4 Select Manage Array The Manage Array window appears 5 Select Consistency Check on the Manage Array window A menu window appears 6 Press Y to start the consistency check The consistency check runs a read read compare algorithm in the background If it encounters any data miscompares it stores the information in a bad block table Page 19 Chapter 3 Creating Mirrored Volumes Other Configuration Tasks SAS2 Integrated RAID Solution User Guide 3 4 3 Activating an Array A volume array can become inactive if for example you remove it from one controller or computer and install it on a different one The Activate Array option allows you to reactivate
48. owerdown situations Use of metadata to store volume configuration on disks in a mirrored volume Automatic background resynchronization while host I Os continue Background media verification which ensures that data on mirrored volumes is always accessible The LSI Integrated RAID solution supports one or two mirrored volumes on each LSI SAS2 controller or one mirrored volume and one Integrated Striping volume Typically one of these volumes is the boot volume Boot support is available through the firmware of the LSI SAS2 controller that supports the standard Fusion MPT interface The runtime mirroring of the boot disk is transparent to the BIOS the drivers and the operating system Host based status software monitors the state of the mirrored disks and reports any error conditions The following figure shows an Integrated Mirroring volume in which the second disk is a mirrored copy of the data on the first primary disk LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 2 Overview of Integrated RAID Mirrored Volumes Operation of Mirrored Volumes Integrated Mirroring Volume Primary NVSRAM For Write Journaling LSI Memory Bus Fusion MPT SAS2 Controller FLASH For Configuration 3_00006 00 Figure 1 Typical Integrated Mirroring Implementation The following figure shows the logical view and physical view of an Integrated Mirroring volume Each logical block addres
49. ped volumes The Integrated RAID solution is currently available as an optional component of the Fusion MPT architecture on LSI SAS2 controllers Page 5 Chapter 1 Introduction to the Integrated RAID Solution Benefits and Features SAS2 Integrated RAID Solution User Guide 1 2 Benefits and Features The LSI Integrated RAID solution has the following benefits and features Support for up to 10 disks per Integrated RAID volume with one or two volumes on each SAS2 controller Each controller can support can support 14 volume drives including one or two hot spare disks Support for two disk Integrated Mirroring volumes RAID 1 Support for online capacity expansion OCE for RAID 1 volumes OCE allows you to increase the size of a RAID 1 volume by replacing the disk drives with higher capacity drives Low cost RAID volume creation which meets the needs of most internal RAID installations Easy installation and configuration Support for booting from any kind of Integrated RAID volume Ability to operate without special operating system specific software High reliability and data integrity Nonvolatile write journaling Physical disks in a volume are not visible to the operating system OS or to application software m Low host CPU and PCI bus utilization Processing power provided by Fusion MPT architecture Shared memory architecture minimizes external memory requests Device hardware and firmware contain the functiona
50. r array on this adapter Select Manage Array The Manage Array window appears Select Delete Array A menu window appears Either press Y to delete the array or press N to cancel the deletion process After a pause the utility deletes the array You can use the SAS2 BIOS CU to locate and identify a specific physical disk drive in a disk enclosure by flashing the drive s LED You can also flash the LEDs of all the disk drives in a RAID volume if they are in a disk enclosure When you add a disk drive to a new mirrored volume the LED on the disk drive starts flashing The LED stops flashing when you finish creating the volume You can locate individual disk drives from the SAS Topology window by flashing their LEDs To do this follow these steps 1 Select the desired SAS2 controller on the Adapter List window and press Enter The Adapter Properties window appears Highlight SAS Topology and press Enter The SAS Topology window appears Select the disk in the Device Identifier column and press Enter The LED on the disk flashes until you press a key to stop it To identify all the disk drives in a volume select the volume in the left column of the SAS Topology window and press Enter The LEDs flash on all disk drives in the volume until you press a key to stop them LSI Corporation Confidential August 2010 SAS2 Integrated RAID Solution User Guide Chapter 5 Creating Integrated Striping Vo
51. rrored volumes Page 7 Chapter 2 Overview of Integrated RAID Mirrored Volumes 2 3 Operation of Mirrored Volumes Page 8 Operation of Mirrored Volumes SAS2 Integrated RAID Solution User Guide Ability of mirrored volumes to run in optimal mode or in degraded mode if one mirrored disk in an Integrated Mirroring volume fails or if one or more mirrored disks fail in an Integrated Mirroring Striping volume or Integrated Mirroring Enhanced volume Support for hot swapping Support for online capacity expansion OCE for RAID 1 volumes OCE allows you to increase the size of a RAID 1 volume by replacing the existing disk drives with higher capacity disk drives Data is protected during the expansion process and the RAID 1 volume remains online Presentation of a single virtual drive to the operating system for each mirrored volume Support for both SAS and SATA disks although you cannot combine the two types of disks in the same volume However an LSI SAS2 controller can support one volume with SATA disks and a second volume with SAS disks Automatic background initialization after volume creation Consistency checking Fusion MPT architecture Menu driven BlIOS based configuration utility Error notification in which the drivers update an OS specific event log Support for SCSI Enclosure Services SES status LED Write journaling which allows automatic synchronization of potentially inconsistent data after unexpected p
52. s Online ONL The drive is operational and is part of a logical drive Hot Spare HSP The drive isa hot spare that is available to replace a failed drive in an array Ready RDY The drive is ready for use as a normal disk drive or it is ready to be assigned to a disk array or a hot spare pool Available AVL The drive may or may not be ready and it is not suitable for use in an array or a hot spare pool Failed FLD The drive failed and is now offline Missing MIS The drive has been removed or is not responding Standby SBY The device is not a hard disk device Out of Sync OSY The drive which is part of a logical drive is not in sync with other drives that are part of the logical drive Degraded DGD The drive is part of a logical drive and is in degraded state Rebuilding RBLD The drive is part of a logical drive and is currently rebuilding Optimal OPT The drive is optimal and is part of a logical drive Physical device Drive Type values are as follows SAS HDD The drive is a SAS HDD SATA_HDD The drive is a SATA HDD SAS SSD The drive is a SAS SSD SATA SSD The drive is a SATA SSD Physical device Protocol values are as follows SAS The drive supports SAS protocol SATA The drive supports SATA protocol The HOTSPARE command adds a hot spare drive to spare pool 0 or deletes a hot spare drive The capacity of the hot spare drive must be greater than or equal to the capaci
53. s LBA is mirrored on the second disk Logical View Physical View 3_00007 00 Figure 2 Integrated Mirroring Volume You can configure an Integrated Mirroring Enhanced volume with up to 10 mirrored disks The following figure shows the logical view and physical view of an Integrated Mirroring Enhanced volume with three mirrored disks The firmware writes each mirrored stripe to a disk and mirrors it to an adjacent disk RAID 1E is another term for this type of mirrored configuration LSI Corporation Confidential August 2010 Page 9 Chapter 2 Overview of Integrated RAID Mirrored Volumes Operation of Mirrored Volumes SAS2 Integrated RAID Solution User Guide Logical View Physical View Mirrored Stripe 1 Mirrored Stripe 1 Mirrored Stripe 1 Mirrored Stripe 2 Mirrored Stripe 2 Mirrored Stripe 2 Mirrored Stripe 3 Mirrored Stripe 3 Mirrored Stripe 3 cy Mirrored Stripe 4 A Mirrored Stripe 4 Mirrored Stripe 5 Mirrored Stripe 4 Mirrored Stripe 5 Mirrored Stripe 6 Mirrored Stripe 6 Mirrored Stripe N Mirrored Stripe N 1 Mirrored Stripe N Mirrored Stripe N 3_00008 00 Figure 3 Integrated Mirroring Enhanced with Three Disks You can configure an Integrated Mirroring Striping volume with an even number of disks ranging from four minimum to ten maximum The following figure shows the logical view and physical view of an Integrated Mirroring Striping volume with four mirrored disks The firmware writes each
54. s KEEN die ew Ob bow de ce a EE SR eens EEA RE EE ceeds 12 24 9 Consistency CHECK ER scaleissiraon ie Eet EEN Ne acne Siw ups ERE EE EEN alates RGU ege E 12 24 10 Make Data Consistent 1 3 34 06 senri rnaen SEENEN dine EE cia ve 12 Chapter 3 Creating Mirrored Volume 13 3 1 Mirrored Volume Configuration Overview 13 3 2 Creating Mirrored Volumes siris olen ence Gntdceiioaaceegae coeds chee Gas ceo dta salve eet A E EREE ds eee Meads N e ca Betas 13 3 2 1 Creating an Integrated Mirroring Volume 14 3 2 2 Creating an Integrated Mirroring Enhanced or Integrated Mirroring Striping Volume 15 3 2 3 Expanding an Integrated Mirroring Volume with OCE 0 cece eee cece nen ene ene eee e eden eee nee eeneneees 16 3 3 Managing Hot Spare Disks ene EE EEN se EE pe nee be SEENEN EE NEE EEN EE E be ead tees 17 3 3 Creating HOt Spare DISKS vierge saeco geen ate RENE ele ee ees ENNER we saad se ewe eebe 17 3 3 2 Deleting Hot Spare DiSkS ot sc eee nace cha ieres T uni tha ENEE EE ee eee ER d EAE Seen te EE ead 18 3 4 Other Configuration Tasks eg Z0N ENER case cp avin ERENNERT NEES ANE MEN KEE SEN Sen 19 3 4 1 Viewing Volume Properties 0 cece cece cece een ee ne ne een enn eden eee t dene need ene e Ete e ene an ees 19 3 42 Running a Consistency Check eege dia NEES EEN EK S E RRENE Se RENE eee hem 19 343 Activatingan Array fycisis adic eE NE bene ees EE EE Rodda ews E eee RE RE 20 3 44 Deleting an Aay EE 20 3 4 5 Locating
55. ser Guide 2 4 6 Disk Write Caching By default the Integrated RAID firmware disables disk write caching for mirrored volumes It does this to ensure that the write journal entry stored in nonvolatile static RAM NVSRAM is always valid If you enable disk write caching not recommended you may cause the disk write log to be invalid 2 4 7 NVSRAM Usage The Integrated RAID firmware requires at least a 32 KB NVSRAM to perform write journaling for mirrored volumes on LSI SAS2 controllers The NVSRAM also preserves configuration information across reboots The firmware uses write journaling to verify that the disks in the mirrored volume are synchronized with each other 2 4 8 Background Initialization Background initialization BGI is the process of copying data from primary to secondary disks in a mirrored volume The Integrated RAID firmware starts BGI automatically as a background task when it creates a volume The volume remains in the Optimal state while BGI is in progress 2 4 9 Consistency Check A consistency check is a background process that reads data from primary and secondary disks in a mirrored volume and compares it to make sure the data is identical on both disks You can use the LSI SAS2 BIOS Configuration Utility to run a consistency check on a mirrored volume 2 4 10 Make Data Consistent If it is enabled in the Integrated RAID firmware the make data consistent MDC process starts automatically and runs in the backgrou
56. t the LSI SAS adapter with the RAID 1 volume and then press Enter The Adapter Properties window appears Use the arrow keys to select RAID Properties and then press Enter The Select New Array Type window appears Select View Existing Array The View Array window appears If necessary press Alt N to switch to the RAID 1 volume with the new higher capacity disk drives Select Manage Array The Manage Array window appears Select Online Capacity Expansion A menu window appears with a warning message and with options to start the expansion process or quit Press Y to start the expansion The RAID Properties window appears when the expansion process completes Run a commercial tool specific to the operating system to move or increase the size of the partition on the newly expanded RAID1 volume You can create one or two global hot spare disks to protect the data on mirrored volumes on an LSI SAS2 controller You can also delete hot spare disks Follow these steps to add global hot spare disks to an existing volume The steps begin with the Adapter List window that appears when the configuration utility starts 1 In the Adapter List window use the arrow keys to select the LSI SAS adapter on which you want to create hot spare disks and then press Enter The Adapter Properties window appears as shown in Figure 5 Use the arrow keys to select RAID Properties and then press Enter The Select New Array Type window appears
57. ty of the smallest drive in the RAID volume You can verify this by using the DISPLAY command on the drive Page 37 Appendix A Commands Command Line Parameters Program Return Value A 3 6 STATUS Command Page 38 Command Line Parameters Program Return Value SAS2 Integrated RAID Solution User Guide Observe the following rules when creating hot spare disks You cannot create a hot spare disk unless at least one RAID1 RAID10 or RAID1E volume already exists m You cannot create a hot spare and add it to an inactive Integrated RAID volume For hard disk drives you cannot add a SAS hot spare disk if the existing volumes on the controller use SATA disks You cannot add a SATA hot spare disk if the existing volumes on the controller use SAS disks For solid state drives you can add a SAS hot spare SSD to a volume with SATA SSDs and you can add a SATA hot spare SSD to a volume with SAS SSDs if the Integrated RAID firmware allows it This depends on the values in the static fields in Manufacturing Page 4 For more information see the Fusion MPT 2 0 MPI Specification Guide m The maximum allowable number of hot spare drives depends on the value of the MaxGlobalHotSpares field in IOC Page 6 Normally the maximum is two global hot spares per controller You cannot add an SSD hot spare to a volume that has HDDs or vice versa sas2ircu lt controller gt hotspare delete lt Enclosure Bay gt m lt co
58. types of installed controllers Adapter Vendor Devic SubSys SubSys Index Type ID ID Pci Address Ven ID Dev ID 0 SAS2008 1000h 72h 00h 01h 00h 00h 1000h 00dah 1 SAS2008 1000h 72h 00h 05h 00h 00h 1000h 00dah Page 39 Appendix A Commands A 3 8 MFGPAGE Command Command Line Parameters Program Return Value A 3 9 CONSTCHK Command Command Line Parameters Program Return Value A 3 10 ACTIVATE Command Page 40 Command Line Parameters Program Return Value SAS2 Integrated RAID Solution User Guide The MFGPAGE command updates information on manufacturing pages Only DOS and EFI support this command sas2ircu lt controller gt mfgpage lt passcode gt lt mfgpage_ gt lt offset gt lt value gt m lt controller_ gt The index of the controller with the manufacturing pages you want to update m lt passcode gt The passcode required for DOS access lt mfgpage_ gt The manufacturing page 4 or 10 that requires an update lt offset gt The DWord offset of the specified manufacturing page that requires an update in hexadecimal format m lt value gt The value for the offset to be modified in hexadecimal format 0x00 SUCCESS Command completed successfully 0x01 FAILURE Bad command line arguments or operational failure 0x02 ADAPTER_NOT_FOUND Cannot find specified adapter The CONSTCHK command sends requests to the Integrated RAID firmware to start a consistency check operation
Download Pdf Manuals
Related Search
Related Contents
INCA SMART 24 & 28"GRAY Projecta Pre-Installation Box Yamaha AW4416 Stereo System User Manual manuel d`utilisation pour perceuse électrique de 3/8 SERVICE MANUAL - Mitsubishi Electric Cooling & Heating barzellette 2007.08.05.odt Tripp Lite DB9F-RJ45 User's Manual BENDIX BW2377 User's Manual Paradyne 8785 Network Card User Manual Copyright © All rights reserved.
Failed to retrieve file