1. Port 0 LED Table 2 7 describes the LSI7102XP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 7 LSI7102XP LC Link Activity Link Fault LEDs ry Fat LED Appearance Green Blinking Physical Characteristics 2 11 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 3 LSI7102LXP LC Host Adapter Configuration 2 12 The LSI Logic LSI7102LXP LC is a single channel 2 Gbit s FC adapter One LC optical connector is used for I O which is accessible through the module bracket The LSI7102LXP LC host adapter uses the LSIFC919X processor providing one Fusion MPT channel The LSI7102LXP LC is a PCI short card the dimensions are 6 625 inches x 2 53 inches The external FC connections are made through a 2 Gbit s SFP optical module The component height on the top and bottom of the board conforms to the PCI X 133 Specification Revision 1 0a Figure 2 3 illustrates the major components on the LSI7102LXP LC Figure 2 3 LSI7102LXP LC Host Adapter Configuration LSI7102XP LC TEE ETE EEE EEE 6S SS a Voltage Regulator SRAM X2 eee Oso LSIFC919x 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 4 LSI7102LXP LC Connector and Indicator LED The LSI7102LXP LC I O bracket is configured as shown in Figure 2 4 The LC connect
2. 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 18 LSI7402EP Connectors and Indicator LEDs The LSI7402EP I O bracket is configured as shown in Figure 2 18 The Port 0 Port 1 Port 2 and Port 3 connectors provide the connections from the adapter channels to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 18 LSI7402EP Connectors and Indicator LEDs Port 3 Port 2 LUC Port 1 Port 0 Port 3 LED oo Port2 LED Port 1 LED Oo PortO LED Table 2 15 describes the LSI7402EP Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 15 LSI7402EP Link Activity Link Fault LEDs LED Appearance Green Blinking Physical Characteristics 2 27 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 28 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved Chapter 3 Firmware Installation Procedure This chapter provides information about installing and configuring FC firmware and includes the following sections e Section 3 1 FC Firmware e Section 3 2 Download New FC Firmware e Section 3 3 Update the FC Firmware e Section 3 4 Advanced User Adjusting Default Firmware Settings e
3. LSI7202XP LC TEEETEEEEE EEE EET j Osc LSIFC929x Voltage Regulator ae 2 16 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 8 LSI7202LXP LC Connectors and Indicator LEDs The LSI7202LXP LC I O bracket is configured as shown in Figure 2 8 The LC connectors provide the connections from the adapter channels to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 8 LSI7202LXP LC Connectors and Indicator LEDs Port 1 LED Port 1 Port 0 Port 0 LED Table 2 10 describes the LSI7202LXP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 10 LSI7202LXP LC Link Activity Link Fault LEDs LED Appearance Green Blinking Physical Characteristics 2 17 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 9 LSI7202EP LC Host Adapter Configuration 2 18 The LSI Logic LSI7202EP LC is a dual channel 2 Gbit s FC adapter Two LC optical connectors used for I O are accessible through the module bracket The LSI7202EP LC uses the LSIFC929X providing two Fusion MPT channels The LSI7202EP LC is a PCI short card the dimensions are 6 875 inches x 4 2 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top a
4. Target 0 Unit 0 Disk SEAGATE ST39173FC 6615 WWN 2100002037109d76 Port ID d9 Target 1 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 210000203710565a Port ID 17 Target 2 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037105212 Port ID 1 Target 3 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037103da8 Port ID 26 BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved Target 4 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 210000203710324a Port ID 73 pci 8 700000 scsi 6 Target 6 Unit 0 Removable Read Only device PLEXTOR CD ROM PX 20TS If the FC devices on your IntraServer adapter are not identified by your system check the following e Is the FC enclosure powered on e Does the LED on the adapter indicate Link Note that Link is valid only after the device is probed e Does the LED on the switch or remote enclosure indicate Link e Does the Link SPEED parameter selected by the adapter match that of the bus 1G 2G or Auto If you do not see disks the following additional debug information may help to identify the problem 4 7 3 Verifying Installation Use the following procedure to verify installation of your Fusion MPT adapter in the system Step 1 Power up the system Step 2 When the banner is displayed press the STOP A keys to interrupt the boot process and stop at the ok prompt Step 3 Use the show devs command to lis
5. page 2 9 for details 2 4 4 FC Link Activity Link Fault LED The LSI Logic 2 Gbit s host adapters provide dual purpose LEDs that indicate activity on the FC link These LEDs one per port are visible near the ports on the bracket Figure 2 4 shows the appearance of the Link Activity Link Fault LED that represents the given link status for each of the LSI Logic host adapters Table 2 4 LED Appearance to Represent Link Status Activity LSI7102XP LC Green Blinking Yellow LSI7102LXP LC Green Blinking Yellow LSI7202XP LC Green Blinking Yellow LSI7202LXP LC Green Blinking Yellow LSI7202EP LC Green Blinking Yellow LSI7202EP Green Blinking Yellow LS17402XP LC Green Blinking Yellow LS17402EP LC Green Blinking Yellow LSI7402EP Green Blinking Yellow 2 5 PCI System ID Values All LSI Logic 2 Gbit s host adapters share common PCI Vendor ID VID values and are assigned device ID DID values to allow drivers and BIOS to recognize them as 2 Gbit s capable FC products Table 2 1 provides the VID and DID for all LSI Logic 2 Gbit s FC host adapters PCI System ID Values 2 7 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Table 2 5 PCI System ID Values Host Adapter VID Number DID Number LSI7102XP LC 0x1000 0x0628 LSI7102LXP LC 0x1000 0x0628 LSI7202XP LC 0x1000 0x0626 LS I7202LXP LC 0x1000 0x0626 LS
6. Note The OpenBoot BIOS Fcode provides help when you enter a command that does contain the proper arguments In this case OpenBoot responds with usage syntax Figure 4 4 Setting Device 0 as Persistent ok 0 0 set persistent ok show persistent Entry 1 WWN 200000203710c4e8 Target 0 Note The command sequence in Figure 4 4 records an entry for device 0 as item 0 in the persistent device list Figure 4 5 Clearing Persistent Device Map ok 1 clear persistent Entry 1 has been cleared ok show persistent ok Note The command sequence in Figure 4 5 may be used to clear an entry in the persistent device map Entry 1 has been deleted from the table and the table is now empty BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 7 8 Manual Selection of FC Topology Under certain configurations you may want to force the selection of FC topology and disable the auto detect mechanism in the FC adapter This can be done on a port by port basis by using the following procedure Note It should not be necessary to change from automatic detection of topology Also firmware version 1 00 03 is the earliest version to support this functionality The following is an example of how to select a manual topology N_Port or NL_Port on a selected FC port Select the controller you want to modify as follows ok show disks a pci 1f 0 pci l1 IntraServer fc 2 disk b pci 1lf 0 pci
7. To update the firmware complete the following steps Step 1 Ensure that the host adapter is properly installed in the system PCI slot Step 2 Insert the LSI Logic FC firmware diskette into drive A Step 3 Boot the system to the DOS prompt A gt Step 4 Execute the MPTUtil program directly from the DOS command line by typing at the prompt A MPTutil The MPTUtil program identifies all LSI Logic host adapters in the system and it allows you to select which adapter to update Figure 3 4 Figure 3 4 MPTUtil Device Selection LSIMPTUTIL 1 00 00 Vendor Device Choice ID ID Bus Device 1000h 0626h Oh 28h LSI 929X Fibre Channel Host Adapter 2 Refresh Which chip 0 to quit __ Update the FC Firmware 3 7 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Step 5 The MPTUtil program displays a menu of options Figure 3 5 To update the firmware select option a Update Firmware Figure 3 5 MPTUtil Options LSI Logic Corp FC SAS Serial EEPROM FLASH Utility LSIMPTUTIL 1 00 00 Copyright c 2005 LSI Logic Corporation All rights reserved KKEKKKKKKKKKKKKKKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KK KKKKKKEKKK Currents Port 0 Port 1 World Wide P N 0x100000062B092448 0x100000062B092449 World Wide P N 0x200000062B092448 0x200000062B092449 Topology Auto fs 6 1 6 ere Auto Device Pathing All Paths to a device Protocol Support INIT TARG LAN Firmwar
8. Table 2 13 LSI7402XP LC Link Activity Link Fault LEDs LED Appearance Green Blinking Physical Characteristics 2 23 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 15 LSI7402EP LC Host Adapter Configuration 2 24 The LSI Logic LSI7402EP LC is a quad channel 2 Gbit s FC adapter Four LC optical connectors used for I O are accessible through the module bracket The LSI7402EP LC uses two LSIFC929X devices providing four Fusion MPT channels The LSI7402EP LC is a PCI short card the dimensions are 6 875 inches x 4 2 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI Express Specification Revision 1 0a Figure 2 15 illustrates the major components on the LSI7402EP LC Figure 2 15 LSI7402EP LC Host Adapter Configuration LSI7402EP CEECEE Ae LSIFC929X Port 3 SEP l LSIFC929X Port 2 SFP Flash i Port 1 SFP Backo PCI Express Voltage SRAM X2 Port 0 SFP Osc Bridge f eel 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 16 LSI7402EP LC Connectors and Indicator LEDs The LSI7402EP LC I O bracket is configured as shown in Figure 2 16 The LC connectors provide the connections from the adapter channels to the FC su
9. what nt Many types of errors are reported through the LED on the LSI Logic Host Adapter boards When these errors occur the LED flashes a four digit sequence which is the error code These types of errors should be reported to LSI Logic Technical Support The technical support representative will ask for additional system configuration information including the type of system used the FC configuration and type of peripherals including version numbers and the sequence of events when the error occurred 3 12 Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All rights reserved Chapter 4 BIOS Features This chapter describes the Fibre Channel FC BIOS and Configuration Utility and includes the following sections e Section 4 1 LSI Logic Boot BIOS e Section 4 2 Starting the LSI Logic Boot BIOS Configuration Utility e Section 4 3 Using the LSI Logic Boot BIOS CU e Section 4 4 Main Menu e Section 4 5 Exiting the LSI Logic Boot BIOS Configuration Utility e Section 4 6 Troubleshooting e Section 4 7 OpenBoot BIOS A BIOS is the ROM code that the system loads to facilitate booting from FC drives The BIOS also contains an embedded configuration manager with which you configure options provided by the firmware The LSI Logic BIOS integrates with a standard system BIOS extending the standard disk service routine provided through INT13h Tw
10. All rights reserved 2 8 6 LSI7202XP LC Connectors and Indicator LEDs The LSI7202XP LC I O bracket is configured as shown in Figure 2 6 The LC connectors provide the connections from the adapter channels to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 6 LSI7202XP LC Connectors and Indicator LEDs Port 1 LED Port 1 Port 0 Port 0 LED Table 2 9 describes the LSI7202XP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 9 LSI7202XP LC Link Activity Link Fault LEDs ey Frat LED Appearance Green Blinking Physical Characteristics 2 15 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 7 LSI7202LXP LC Host Adapter Configuration The LSI Logic LSI7202LXP LC is a dual channel 2 Gbit s FC adapter Two LC optical connectors used for I O are accessible through the module bracket The LSI7202LXP LC uses the LSIFC929X providing two Fusion MPT channels The LSI7202LXP LC is a PCI short card the dimensions are 6 625 inches x 2 53 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI X 133 Specification Revision 1 0a Figure 2 7 illustrates the major components on the LSI7202LXP LC Figure 2 7 LSI7202LXP LC Host Adapter Configuration
11. Handle plug in boards by the edge do not touch board components or gold Detailed Installation Procedure 1 3 Copyright 2002 2005 by LSI Logic Corporation All rights reserved connector contacts LSI Logic recommends using a static ground strap Step 5 Locate the slots for PCI plug in board installation Refer to the user s manual supplied with your computer to confirm the location of the PCI slots This host adapter requires a 32 bit or 64 bit PCI slot that allows bus master operation If a 32 bit PCI slot is used the portion of the J1 connector opposite the bracket remains uninserted Refer to Table 1 2 for details Note For this host adapter to function as a 64 bit device it must be inserted into a 64 bit PCI slot If the host adapter is inserted into a 32 bit PCI slot it functions as a 32 bit device Step 6 On the back of the computer remove the blank bracket panel that is aligned with the PCI slot you intend to use Save the bracket screw Figure 1 1 Hardware Connections for the LSI Logic Host Adapter Fibre Channel Link Activity Link Fault LED SFP Transceiver LSI Logic Host Adapter PCI Bus Edge Connector J1 Installation Procedures Copyright 2002 2005 by LSI Logic Corporation All rights reserved Step 7 Carefully insert PCI Bus edge connector J1 see Figure 1 1 of the host adapter into the PCI slot Make sure the edge connector is properly aligned before pressing the board into place
12. 12 6 V C to 55 14 4 W 12 6 V plus SFP power if any LSI7202EP C to 55 LSI7402XP LC C to 55 LSI7402EP LC LSI7402EP C to 55 2 3 2 Thermal Atmospheric Characteristics The thermal atmospheric characteristics of the LSI Logic 2 Gbit s family of FC host adapters are e Temperature range 0 C to 55 C dry bulb 100 linear feet per minute LFPM airflow minimum e Relative humidity range 5 to 90 noncondensing e Maximum dew point temperature 32 C The following parameters define the storage and transit environment for the LSI Logic 2 Gbit s family of FC host adapters e Storage Temperature 45 C to 85 C dry bulb e Relative Humidity Range 0 to 95 noncondensing Physical Environment 2 5 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 3 3 Electromagnetic Compliance These boards are designed and implemented to minimize susceptibility to electromagnetic emissions and the effects of electromagnetic discharge The boards are tested to comply with Class B and carry markings for CE VCCI Canada C Tick and the FCC 2 3 4 Safety Characteristics The bare boards meet the requirements of flammability rating UL 94 V O The bare boards are also marked with the supplier name or trademark type and UL flammability rating Because these boards are installed in a PCI bus slot all voltages are below the SELV 42 4 V limit 2 4 Operational Envir
13. Indicator LEDs LSIUtil Device Selection LSIUtil Download Options LSIUtil File Download MPTUtil Device Selection MPTUtil Options Interrupt Coalescing Values Select Controller Select Device Inserting Disk Name in Command Line Setting Device 0 as Persistent Clearing Persistent Device Map Copyright 2002 2005 by LSI Logic Corporation All rights reserved 1 4 1 5 2 10 2 11 242 2 13 2 14 2 15 2 16 247 2 18 2 19 2 20 ani 2 22 223 2 24 2 25 2 26 2 27 3 5 3 6 3 6 3 7 3 8 3 11 4 15 4 16 4 16 4 16 4 16 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Tables 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 AN 2z 2 13 2 14 215 LSI Logic 2 Gbit s FC Host Adapter Descriptions Hardware and Software Requirements Maximum Power Requirements LED Appearance to Represent Link Status PCI System ID Values PCI Subsystem ID Values LSI7102XP LC Link Activity Link Fault LEDs LSI7102LXP LC Link Activity Link Fault LEDs LSI7202XP LC Link Activity Link Fault LEDs LSI7202LXP LC Link Activity Link Fault LEDs LSI7202EP LC Link Activity Link Fault LEDs LSI7202EP Link Activity Link Fault LEDs LSI7402XP LC Link Activity Link Fault LEDs LSI7402EP LC Link Activity Link Fault LEDs LSI7402EP Link Activity Link Fault LEDs Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 2 2 3 25 2 7 2 8 2 8 211 2 13 2 15 2 17 2 19 2 21 2 23 2 25 2 27 xi xii
14. Settings 4 10 In certain circumstances advanced users may want to change settings for an individual adapter or port without affecting the other adapters in the system Specific examples of such settings are FC bus speed host adapter ID SCSI only not applicable to FC and Interrupt Coalescing To select a specific Fusion MPT adapter as the current adapter use the select command Selecting a port or adapter brings the port online and allows you to show or set certain adapter specific parameters BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved You should use caution while issuing the following commands because some commands such as forcing 1 Gbit s operation on a 2 Gbit s FC loop could render the bus unusable 4 7 4 1 select Command Use the select OpenBoot command to choose the adapter entry This opens the port to bring the port online ok select pci 8 700000 IntraServer fc 1 4 7 4 2 properties Command Use the properties command to show the adapter properties ok properties firmware version 1 02 00 mpt version 1 00 scsi initiator id 00 00 00 Of assigned addresses 81001010 00000000 00000700 00000000 00000100 83001014 00000000 001a0000 00000000 00020000 8300101c 00000000 00190000 00000000 00010000 82001030 00000000 02000000 00000000 00100000 compatible 70 63 69 31 33 65 39 2c 36 32 31 00 70 63 69
15. and LSIFC919X processors contain the FC functionality for all the LSI Logic 2 Gbit s FC host adapters The LSIFC929X and LSIFC919X processors generate signal timing and link protocol in compliance with FC standards The FC interface includes these features e 2 Gbit s serial link e LSIFC929X and LSIFC919X processor functionality Class 3 Arbitrated Loop AL Fabric Point to Point 2 Kbyte frame payloads Multiframe buffering e Link activity link fault LED 2 3 Physical Environment 2 4 This section provides information about the physical electrical thermal and safety characteristics of the LSI Logic 2 Gbit s family of FC host adapters Additionally these boards are compliant with FCC electromagnetic standards 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved Electrical Characteristics Table 2 3 lists the maximum power requirements and includes all of the LSI Logic 2 Gbit s FC host adapter boards under normal operation Table 2 3 Host Adapter PCI 3 3 V Maximum Power Requirements Over the Operating Range LSI7102XP LC 4 7 W 3 6V C to 55 C LSI7102LXP LC 47W 3 6V C to 55 LSI7202XP LC 6 5 W 3 6 V C to 55 LSI7202LXP LC 6 5 W 3 6 V C to 55 LSI7202EP LC 11 5 W 12 6 V C to 55 10 7 W 12 6 V plus SFP power if any 14 7 W 3 6 V plus 4 2 W 5 25 V 16 0 W
16. as shown in Figure 1 2 The bracket around the Small Form Factor Pluggable SFP transceiver cages should fit where you removed the blank panel Figure 1 2 Inserting the LSI Logic Host Adapter Be Bracket Screw Ke PCI Slots ear PCI Slots Step 8 Secure the board with the bracket screw see Figure 1 2 then make the external FC link connection Detailed Installation Procedure 1 5 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 1 6 Installation Procedures Copyright 2002 2005 by LSI Logic Corporation All rights reserved Chapter 2 2 Gbit s FC Host Adapter Characteristics This chapter provides specific details about the physical environment associated with the 2 Gbit s family of FC host adapters This chapter includes the following sections e Section 2 1 General Description e Section 2 2 Features e Section 2 3 Physical Environment e Section 2 4 Operational Environment e Section 2 5 PCI System ID Values e Section 2 6 PCI Subsystem ID Values e Section 2 7 Unique World Wide Name e Section 2 8 Physical Characteristics 2 1 General Description The LSI Logic 2 Gbit s family of FC host adapters makes use of state of the art 2 Gbit s FC technology to provide the highest possible performance and most flexible storage configuration available These LSI Logic host adapters support 1 Gbit s or 2 Gbit s FC speeds and
17. channel 2 Gbit s FC adapter Four LC optical connectors used for I O are accessible through the module bracket The LSI7402XP LC uses two LSIFC929X devices providing four Fusion MPT channels The LSI7402XP LC is a PCI short card the dimensions are 6 875 inches x 4 2 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI X 133 Specification Revision 1 0a Figure 2 13 illustrates the major components on the LSI7402XP LC Figure 2 13 LSI7402XP LC Host Adapter Configuration LSI7402 02XP aE aE LSIFC929X Port 3 SFP PCI X Bridge 2 22 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 14 LSI7402XP LC Connectors and Indicator LEDs The LSI7402XP LC I O bracket is configured as shown in Figure 2 14 The LC connector provides the connection from the adapter channel to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 14 LSI7402XP LC Connectors and Indicator LEDs Port 3 Port 2 LUC Port 1 Port 0 Port 3 LED oo Port2 LED Port 1 LED Oo PortO LED Table 2 13 describes the LSI7402XP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link
18. devices 4 3 Using the LSI Logic Boot BIOS CU This section provides the menu formats and user inputs available to inform users about the boot BIOS CU prior to running it All BIOS CU screens that display various menus are partitioned into fixed areas This area provides static general help text information 4 4 Main Menu When you invoke the LSI Logic boot BIOS CU the Main menu appears This screen displays a scrolling list of up to 256 host adapters in the system and information about each of them Use the arrow keys to highlight a host adapter Then press ENTER to view and modify the selected host adapter properties and to gain access to the attached devices After selecting an adapter and pressing Starting the LSI Logic Boot BIOS Configuration Utility 4 3 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 4 1 ENTER the FC Link bus is scanned and the Adapter Properties screen appears On the Main menu two selections are the Boot Adapter List and Global Properties menus Boot Adapter List allows selection and ordering of boot adapters Refer to Section 4 4 4 Boot Adapter List Menu for details Global Properties allows changes to global scope settings Refer to Section 4 4 5 Global Properties Menu for details Only host adapters with LSI Logic Control enabled can be accessed Adapter Properties Menu The Adapter Properties menu allows you to view and modify adapter settings I
19. the LSI7202XP LC Port 1 upper port from the PCI connector select the following menu option Advanced User Adjusting Default Firmware Settings 3 9 Copyright 2002 2005 by LSI Logic Corporation All rights reserved g Toggle Board Speed on Function 1 Successively pressing the F key for Function 0 or the G key for Function 1 toggles the PORT speed setting between these three modes e AUTO e 1 Gbit s e 2 Gbit s Step 3 Exit the FCUtil utility using the menu option q Quit 3 4 2 Adjusting Interrupt Coalescing 3 10 The LSI Logic host adapters can complete multiple I O requests per host interrupt Interrupt coalescing is used to reduce CPU interrupts by pooling multiple disk command completions I O into one interrupt This feature may be enabled or disabled Important LSI Logic has performed significant testing under multiple I O conditions and has determined that interrupt coalescing can be very valuable for small transfer lengths or random transaction oriented I O workloads For this type of workload LSI Logic recommends that the Interrupt Coalescing values be set to a queue depth of 9 with a timeout of 1280 0x500 us This means that the host is interrupted only once for 9 I Os processed by the chip unless 1280 us have passed since the host was last interrupted If the workload is of a large transfer length and sequential LSI Logic recommends that interrupt coalescing be disabled to prevent performance degra
20. you wish to set or show the link speed for the adapter manually use the following procedure Select the port or adapter shown use the port name your system assigns ok select pci 8 700000 IntraServer fc 1 Then enter commands as shown in the following example ok show link speed Link speed selected is 1 Gbaud Current link speed is 1 Gbaud ok set link speed Note The OpenBoot BIOS provides help when you enter a command that does contain the proper arguments In this case OpenBoot responds with usage is lt link speed gt set link speed ok a set link speed Link speed selected is autobaud Link speed has been set Change will tak ffect after system power cycl BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved ok show link speed Link speed selected is autobaud Current link speed is 1 Gbaud Note The system must be power cycled before the changes take effect It is not sufficient to execute the reset all command 4 7 7 Persistent Device Naming One of the most powerful benefits of storage area networks SANs is scalability the freedom to quickly add or delete storage components To facilitate trouble free SAN reconfigurations you can save a list of devices currently connected to the host adapter Later if certain devices are powered off the adapter ensures that the remaining devices appear at the same mount point Technically the LSI Logic host adapter locks the
21. 1 3 2 Installing the Host Adapter Chapter 2 2 Gbit s FC Host Adapter Characteristics 2 1 General Description 2 2 Features 22i PCI X Interface 222 PCI Express Interface 22 3 FC Interface 2 3 Physical Environment 2 3 1 Electrical Characteristics 2 3 2 Thermal Atmospheric Characteristics 2 3 3 Electromagnetic Compliance 2 3 4 Safety Characteristics 2 4 Operational Environment 2 4 1 PCI X Interface 2 4 2 PCI Express Interface 2 4 3 FC Interface 2 4 4 FC Link Activity Link Fault LED 2 5 PCI System ID Values 2 6 PCI Subsystem ID Values 2 7 Unique World Wide Name 2 Gbit s Fibre Channel Host Adapters User s Guide Copyright 2002 2005 by LSI Logic Corporation All rights reserved 1 1 1 2 1 3 1 3 1 3 2A 2 3 2 4 2 4 2 4 2 5 2 5 2 6 2 6 2 6 2 6 2 6 27 2er ot 2 8 2 9 Chapter 3 2 8 Physical Characteristics 2 8 1 LSI7102XP LC Host Adapter Configuration 2 8 2 LSI7102XP LC Connector and Indicator LED 2 8 3 LSI7102LXP LC Host Adapter Configuration 2 8 4 LSI7102LXP LC Connector and Indicator LED 28 5 LSI7202XP LC Host Adapter Configuration 2 8 6 LSI7202XP LC Connectors and Indicator LEDs 28 7 LSI7202LXP LC Host Adapter Configuration 2 8 8 LSI7202LXP LC Connectors and Indicator LEDs 2 8 9 LSI7202EP LC Host Adapter Configuration 2 8 10 LSI7202EP LC Connectors and Indicator LEDs 2 8 11 LSI7202EP Host Adapter Configuration 2 8 12 LSI7202EP Connectors and Indicator LEDs 2 8 13 LSI7402XP LC Host Adapter Configurat
22. 1 IntraServer Ultra2 scsi 1 disk c pci 1lf 0 pci l1 1 ide 3 cdrom d pci 1 0 pci l1 1 ide 3 disk e pci lf 0 pci 1 1 ebus 1 fdthree 14 3203f0 q NO SELECTION Enter Selection q to quit a pci 1lf 0 pci l IntraServer fc 2 disk has been selected Type Y Control Y to insert it in the command line e g ok nvalias mydev Y for creating devalias mydev for pci 1f 0 pci 1 IntraServer fc 2 disk ok select pci 1f 0 pci 1 IntraServer fc 2 Then enter commands as shown in the following example ok show topology Topology selected is auto Current topology is unknown no link ok set topology lt Command with no options provides help usage is lt topology gt set topology topology 1 NL_Port topology 2 N_Port topology a auto OpenBoot BIOS 4 17 Copyright 2002 2005 by LSI Logic Corporation All rights reserved ok 1 set topology opology selected is NL Port Topology has been set Change will tak ffect after system power cycl ok 2 set topology opology selected is N_Port Topology has been set Change will tak ffect after system power cycl ok a set topology opology selected is auto Topology has been set Change will tak ffect after system power cycl Note The system must be power cycled before the changes take effect It is not sufficient to execute the reset all command 4 18 BIOS Features Copyright 2002 2005 by LSI Logi
23. 17402XP LC 0x1000 0x0626 LSI7202EP LC 0x1000 0x0626 LSI7202EP 0x1000 0x0626 LSI7402EP LC 0x1000 0x0626 LSI7402EP 0x1000 0x0626 2 6 PCI Subsystem ID Values 2 8 All LSI Logic 2 Gbit s host adapters are assigned PCI Subsystem Vendor IDs SVIDs and Subsystem IDs SSIDs to allow drivers and BIOS to differentiate the individual host adapter variants The SVID and SSID are listed below Table 2 6 provides the SVID and SSID for all the LSI Logic 2 Gbit s FC host adapters discussed in this user s guide Table 2 6 PCI Subsystem ID Values Host Adapter SVID Number SSID Number LSI7102XP LC 0x1000 0x0530 LSI7102LXP LC 0x1000 0x0530 LSI7202XP LC 0x1000 0x1010 LSI7202LXP LC 0x1000 0x1010 LS17402XP LC 0x1000 0x1020 LSI7202EP LC 0x1000 0x1180 LSI7202EP 0x1000 0x1170 LSI7402EP LC 0x1000 0x1090 LSI7402EP 0x1000 0x1190 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 7 Unique World Wide Name Each LSI Logic FC host adapter is provided with a unique World Wide Name specified by IEEE The last 12 hexadecimal characters of this address appear on a host adapter label This address is stored in the host adapter serial EEPROM 2 8 Physical Characteristics The LSI Logic 2 Gbit s family of FC host adapters includes one to four external FC connectors depending on the host adapter you have chosen The host adap
24. 2005 by LSI Logic Corporation All rights reserved TRADEMARK ACKNOWLEDGMENT LSI Logic the LSI Logic logo design Fusion MPT IntraServer and MyStorage are trademarks or registered trademarks of LSI Logic Corporation Sun Sun Microsystems and Solaris are trademarks or registered trademarks of Sun Microsystems Inc SPARC is a registered trademark of SPARC International Inc UNIX is a registered trademark of The Open Group All other brand and product names may be trademarks of their respective companies DB To receive product literature visit us at http www Isilogic com For a current list of our distributors sales offices and design resource centers view our web page located at http www lsilogic com contacts index html Copyright 2002 2005 by LSI Logic Corporation All rights reserved Audience Organization Preface This book is the primary reference and user s guide for the LSI Logic family of 2 Gbit s Fibre Channel host adapter boards It contains a complete functional description of these boards as well as complete physical and electrical specifications LSI Logic uses Class 1 transceivers on the host adapter boards contained in this user s guide This document assumes that you have some familiarity with Fibre Channel protocol and related support devices and will benefit persons installing and using these boards This document has the following chapters e Chapter 1 Installation Procedures provides bo
25. 31 model ESI 929 reg 00001000 00000000 00000000 00000000 00000000 01001010 00000000 00000000 00000000 00000100 03001014 00000000 00000000 00000000 00020000 0300101c 00000000 00000000 00000000 00010000 02001030 00000000 00000000 00000000 00100000 version 1 00 16 device_type scsi 2 name IntraServer fc fcode rom offset 00000000 66mhz capable devsel speed 00000001 class code 00010000 interrupts 00000001 latency timer 00000040 cache line size 00000010 max latency 00000008 min grant 0000001e subsystem id 00000621 subsystem vendor id 000013e9 revision id 00000001 device id 00000621 vendor id 00001000 OpenBoot BIOS 4 11 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 7 4 3 show children Command While you have the host adapter or port selected use the show children command to display the devices currently connected to this adapter First select the port or adapter shown use the port name your system assigns ok select pci 8 700000 IntraServer fc 1 ok show children PT Version 1 00 Firmware Version 1 02 00 Link is ready port is online WWN 100000a0b8040353 Port ID ef Target 0 Unit 0 Disk SEAGATE ST39173FC 6615 WWN 2100002037109d76 Port ID d9 T Target 1 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 210000203710565a Port ID 17 T Target 2 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037105212 Port ID 1 T Target 3
26. Copyright 2002 2005 by LSI Logic Corporation All rights reserved Chapter 1 Installation Procedures This chapter contains general information about the LSI Logic 2 Gbit s family of Fibre Channel FC host adapters It also provides host adapter installation instructions This chapter describes these topics in the following sections e Section 1 1 General Description e Section 1 2 Quick Installation Procedure e Section 1 3 Detailed Installation Procedure 1 1 General Description LSI Logic provides high performance cost effective 2 Gbit s FC controllers and host adapters The LSI Logic controllers and their associated host adapters that support 2 Gbit s FC contained in this User s Guide are as follows Controller Host Adapter LSIFC919X LSI7102XP LC LSI7102LXP LC LSIFC929X LSI7202XP LC LSI7202LXP LC LSI7202EP LC LSI7202EP LSI7402XP LC LSI7402EP LC LSI7402EP Installing these host adapters into your PCI X system allows you to connect FC devices You can use these FC boards in computer systems with a standard bracket type or with a low profile bracket LSI7102LXP LC or LSI7202LXP LC For specific information about the FC controllers refer to LSIFC929X Dual Channel Fibre Channel I O Processor Technical Manual and LSIFC919X Single Channel Fibre Channel I O Processor Technical Manual 2 Gbit s Fibre Channel Host Adapters User s Guide 1 1 Copyright 2002 2005 by LSI Logic Corporation All rig
27. I7202EP is a PCI short card the dimensions are 6 875 inches x 4 2 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI Express Specification Revision 1 0a Figure 2 11 illustrates the major components on the LSI7202EP Figure 2 11 LSI7202EP Host Adapter Configuration LSI7202EP CEECEE LSIFC929X Port 1 SFP PCI Express Bridge Voltage Regulator 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 12 LSI7202EP Connectors and Indicator LEDs The LSI7202EP I O bracket is configured as shown in Figure 2 12 The Port 0 and Port 1 connectors provide the connections from the adapter channels to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 12 LSI7202EP Connectors and Indicator LEDs Port 1 LED Port 1 Port 0 Port 0 LED Table 2 12 describes the LSI7202EP Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 12 LSI7202EP Link Activity Link Fault LEDs LED Appearance Off Green Blinking Physical Characteristics 2 21 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 13 LSI7402XP LC Host Adapter Configuration The LSI Logic LSI7402XP LC is a quad
28. OS provides support for the BIOS Boot Specification BBS which allows you to choose which device to boot from by selecting the priority To use this feature the system BIOS must be compatible with the BBS If your system supports the BBS use the system BIOS setup menu to select the boot and drive order In the system BIOS setup the Boot Connection Devices menu appears with a list of available boot options Use that menu to select the device and rearrange the order Then exit to continue the boot process 4 2 BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 2 Starting the LSI Logic Boot BIOS Configuration Utility The LSI Logic boot BIOS allows you to change the default configuration of your host adapters using the embedded BIOS Configuration Utility CU When the BIOS loads the following message appears on your monitor Press Ctrl C to start LSI Logic Configuration Utility This message remains on your screen for about five seconds giving you time to start the utility After you press CTRL C the message changes to Please wait invoking LSI Logic Configuration Utility After a brief pause your computer monitor displays the Main menu of the BIOS CU Note Not all devices detected by the CU can be controlled by the BIOS Devices such as tape drives and scanners require loading a device driver specific to that peripheral The BIOS CU allows parameters to be modified for these
29. S 4 7 1 OpenBoot BIOS Features 4 7 2 Identifying the FC Devices 4 7 3 Verifying Installation 4 7 4 Adapter Specific Settings 4 7 5 Interrupt Coalescing 4 7 6 Set FC Link Speed 4 7 7 Persistent Device Naming 4 7 8 Manual Selection of FC Topology Customer Feedback Contents Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 10 4 13 4 14 4 15 4 17 vii viii Contents Copyright 2002 2005 by LSI Logic Corporation All rights reserved Figures tal 12 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 2 10 2 11 Zale 2 13 2 14 219 2 16 21r 2 18 3 1 3 2 3 3 3 4 3 5 3 6 4 1 4 2 4 3 4 4 4 5 Hardware Connections for the LSI Logic Host Adapter Inserting the LSI Logic Host Adapter LSI7102XP LC Host Adapter Configuration LSI7102XP LC Connector and Indicator LED LSI7102LXP LC Host Adapter Configuration LSI7102LXP LC Connector and Indicator LED LSI7202XP LC Host Adapter Configuration LSI7202XP LC Connectors and Indicator LEDs LSI7202LXP LC Host Adapter Configuration LSI7202LXP LC Connectors and Indicator LEDs LSI7202EP LC Host Adapter Configuration LSI7202EP LC Connectors and Indicator LEDs LSI7202EP Host Adapter Configuration LSI7202EP Connectors and Indicator LEDs LSI7402XP LC Host Adapter Configuration LSI7402XP LC Connectors and Indicator LEDs LSI7402EP LC Host Adapter Configuration LSI7402EP LC Connectors and Indicator LEDs LSI7402EP Host Adapter Configuration LSI7402EP Connectors and
30. Section 3 5 Troubleshooting The LSI Logic FC chips and host adapters contain firmware that presents a multiprotocol service layer based on the Fusion MPT architecture The FC firmware provides FCP SCSI 3 over FC Initiator FCP Target and LAN interface services to the host system The FC929X ROM file contains the firmware to operate the LSIFC929X or LSIFC919X controllers used on the associated 2 Gbit s LSI Logic host adapters When updates are necessary LSI Logic releases new firmware to improve the functionality or performance of these host adapters You may download the latest firmware from the LSI Logic web site at http drivers silogic com 2 Gbit s Fibre Channel Host Adapters User s Guide 3 1 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 3 1 3 1 1 FC Firmware This section includes the features description installation and configuration of the FC firmware The installation method varies depending on the operating system LSI Logic provides firmware installation tools for the Windows Linux and Solaris operating systems Features The FC firmware for the LSI Logic FC chips supports the following features e 1 Gbit s and 2 Gbit s FC transfers with AutoNegotiation select 1 Gbit s 2 Gbit s or Auto e 64 bit 66 MHz host PCI bus and 133 MHz PCI X bus backward compatible with 32 bit 33 MHz e Transaction performance capability of gt 70 000 I Os per second both channels e T
31. USER S GUIDE 2 Gbit s Fibre Channel Host Adapters LSI7102XP LC LSI7102LXP LC LSI7202XP LC LSI7202LXP LC LSI7402XP LC LSI7202EP LC LSI7202EP LSI7402EP LC LSI7402EP August 2005 Version 2 1 LSIDKee DB15 000264 02 This document contains proprietary information of LSI Logic Corporation The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation LSI Logic products are not intended for use in life support appliances devices or systems Use of any LSI Logic product in such applications without written consent of the appropriate LSI Logic officer is prohibited Document DB15 000264 02 August 2005 This document describes Version 2 1 of the LSI Logic family of 2 Gbit s Fibre Channel host adapters and will remain the official reference source for all revisions releases of this product until rescinded by an update LSI Logic Corporation reserves the right to make changes to any products herein at any time without notice LSI Logic does not assume any responsibility or liability arising out of the application or use of any product described herein except as expressly agreed to in writing by LSI Logic nor does the purchase or use of a product from LSI Logic convey a license under any patent rights copyrights trademark rights or any other of the intellectual property rights of LSI Logic or third parties Copyright 2002
32. Unit 0 Disk SEAGATE ST39173FC 6258 WWN 2100002037103da8 Port ID 26 T Target 4 Unit 0 Disk SEAGATE ST39173FC 6258 WWN 210000203710324a Port ID 73 T 4 12 BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 7 5 Interrupt Coalescing The LSI Logic host adapters can complete multiple I O requests per host interrupt Interrupt coalescing is used to reduce CPU interrupts by pooling multiple disk command completions I O into one interrupt This feature may be enabled or disabled LSI Logic has performed significant testing under multiple I O conditions and has determined that interrupt coalescing can be very valuable for small transfer lengths or random transaction oriented I O workloads For this type of workload LSI Logic recommends that the Interrupt Coalescing values be set to a queue depth of 9 with a timeout of 1280 0x500 us This means that the host is interrupted only once for 9 I Os processed by the chip unless 1280 us have passed since the host was last interrupted If the workload is of a large transfer length and sequential LSI Logic recommends that interrupt coalescing be disabled to prevent performance degradation Although LSI Logic has determined that these settings are optimal for a wide variety of situations your own I O load may benefit from a deeper queue or a longer timeout LSI Logic provides a mechanism to modify these values and write them to the nonvo
33. asks to store or discard changes if needed 4 4 3 Device Properties Menu The Device Properties menu allows you to view and update individual device settings for an adapter Note The number of fields on the menu requires that you scroll left right to view all the information When accessing this menu use the HOME and END keys to scroll to columns currently not displayed The scroll indicator on the bottom of the menu shows the position of the cursor relative to the first and last columns 4 4 4 Boot Adapter List Menu The Boot Adapter List menu specifies the order in which adapters boot when more than one LSI Logic host adapter is in a system Up to four adapters in a system can be selected as bootable Only one of the four bootable adapters can control a boot volume To select this menu 1 Press F2 while on the Main menu to move the cursor to the menu area 2 Move the cursor to Boot Adapter List with the arrow keys 3 Press ENTER Adapters can be added or deleted using this menu To add an adapter to the boot list press the INSERT key while on the Boot Adapter List Use the arrow keys to select the desired adapter and press ENTER to add it to the end of the Boot Adapter List To remove an adapter from the boot list press the DELETE key while the desired adapter is selected in the Boot Adapter List You can also change the boot order by using the PLUS or MINUS keys For example place the cursor on the adapter that you wan
34. association of an FC target with an alias name reference The LSI Logic host adapter manages the details When you mark a device persistent mapping information is saved on the LSI Logic host adapter in a nonvolatile memory device The following is an example of how to save devices in the persistent device table using LSI Logic Fcode Step 1 Select the controller you want to modify making a selection from the list as shown in Figure 4 1 Figure 4 1 Select Controller ok show disks a pcei 1l 0 pci l IntraServer fc 2 disk b pcei l O pcei l IntraServer Ultra2 scsi l disk c pei l 0 pcei l l ide 3 cdron d pcei l 0 pci l 1l ide 3 disk e pcei lft 0 pci l l ebus l fdthree l4 3203 0 q NO SELECTION Enter Selection q to quit a OpenBoot BIOS 4 15 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 16 Step 2 From the displayed list select a device to mark persistent as shown in Figure 4 2 Figure 4 2 Select Device pci 1lf 0 pci 1 IntraServer fc 2 disk has been selected ok select pci 1f 0 pci l IntraServer fc 2 ok show children MPT Firmware Version 1 02 12 Target 0 Unit 0 Disk SEAGATE ST39173FC 6615 WWN 200000203710c4e8 PortID a3 Step 3 Type Y Ctrl Y to insert disk name in the command line as shown in Figure 4 3 Figure 4 3 Inserting Disk Name in Command Line ok set persistent usage is lt current target id gt lt persistent target id gt set persistent
35. bsystem The indicator LEDs indicate link status activity and link fault Figure 2 16 LSI7402EP LC Connectors and Indicator LEDs Port 3 Port 2 LUC Port 1 Port 0 Port 3 LED oo Port2 LED Port 1 LED Oo PortO LED Table 2 14 describes the LSI7402EP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 14 LSI7402EP LC Link Activity Link Fault LEDs LED Appearance Green Blinking Physical Characteristics 2 25 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 17 LSI7402EP Host Adapter Configuration 2 26 The LSI Logic LSI7402EP is a quad channel 2 Gbit s FC adapter Four connectors used for I O are accessible through the module bracket The LSI7402EP uses two LSIFC929X devices providing four Fusion MPT channels The LSI7402EP is a PCI short card the dimensions are 6 875 inches x 4 2 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI Express Specification Revision 1 0a Figure 2 17 illustrates the major components on the LSI7402EP Figure 2 17 LSI7402EP Host Adapter Configuration LSI7402EP UHV HHH LL LSIFC929X Port 3 SFP LSIFC929X iF Flas 4 Bac l L 4 PCI Express Bridge Voltage l Regulator SRAM X2 I 1
36. c Corporation All rights reserved Customer Feedback We would appreciate your feedback on this document Please copy the following page add your comments and fax it to us at the number shown If appropriate please also fax copies of any marked up pages from this document Important Please include your name phone number fax number and company address so that we may contact you directly for Clarification or additional information Thank you for your help in improving the quality of our documents 2 Gbit s Fibre Channel Host Adapters User s Guide Ver 2 1 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Reader s Comments Fax your comments to LSI Logic Corporation Technical Publications M S E 198 Fax 408 433 4333 Please tell us how you rate this document 2 Gbit s Fibre Channel Host Adapters User s Guide Place a check mark in the appropriate blank for each category Excellent Good Average Fair Poor Completeness of information Clarity of information Ease of finding information Technical content Usefulness of examples and illustrations Overall manual What could we do to improve this document If you found errors in this document please specify the error and page number If appropriate please fax a marked up copy of the page s Please complete the information below so that we may contact you directly for clarification or additional informatio
37. dation Note The LSI7202XP LC LSI7202EP LC and LSI7202EP each have two FC ports and the LSI7402XP LC LSI7402XP LC and LSI7402XP LC each have four FC ports so Interrupt Coalescing must be configured for each port The LSI7102XP LC has only one port Use the following procedure to adjust Interrupt Coalescing depth and timeout values Step 1 To set the link speed of the host adapter execute this command from the DOS command line Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All rights reserved A Mptutil The MPTUtil program identifies all LSI Logic host adapters in the system and allows you to select which adapter to update See Figure 3 4 Step 2 The MPTUtil program displays a menu of options See Figure 3 5 To change Interrupt Coalescing on the LSI7202XP LC Port 0 select the following menu option 1 Change Interrupt Coalescing Values on Port 0 The current values are displayed within a submenu that allows the values to be changed Figure 3 6 Figure 3 6 Interrupt Coalescing Values IOC Page l I Flags weancscnnvanneae Oxo0001 2 Coalescing Timeout 0x500 3 Coalescing Depth 0x9 Flags By default the host adapter has Interrupt Coalescing enabled as indicated by the Flags value of 0x0001 If you want to disable Interrupt Coalescing enter a value of 0x0000 for Flags Interrupt Coalescing should only be disabled to resolve issues in unique sys
38. detect and correctly set the speed of operation automatically LSI Logic host adapters are available with LC optical interfaces using optical SFP transceivers These LSI Logic FC host adapters offer the highest degree of integration available for your PCI X or PCI Express based computer system allowing for maximum performance optimized use of system resources and true Plug and Play installation 2 Gbit s Fibre Channel Host Adapters User s Guide 2 1 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 2 This manual serves as a step by step guide during the installation of your LSI Logic host adapter Table 2 1 lists the 2 Gbit s FC host adapters discussed in this User s Guide Table 2 1 LSI Logic 2 Gbit s FC Host Adapter Descriptions Adapter Description LSI7102XP LC 2 Gbit s PCI X single port standard height bracket optical LSI7102LXP LC 2 Gbit s PCI X single port low profile bracket optical LSI7202XP LC_ 2 Gbit s PCI X dual port standard height bracket optical LSI7202LXP LC 2 Gbit s PCI X dual port low profile bracket optical 2 Gbit s PCI Express dual port standard height bracket optical LSI7202EP LC LSI7202EP i PCI Express dual port standard height bracket no LSI7402XP LC_ 2 Gbit s PCI X quad port standard height bracket optical LSI7402EP LC a PCI Express quad port standard height bracket LSI7402EP ae PCI Express quad port standard
39. e LSIFC929X 1 02 12 2005 06 15 KEKKKKKKKKKKKKKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKK KKKKKKKK KK KKK a Update Firmware b Update BIOS amp Firmware c Upload current firmware to a file d Upload current BIOS to a file f Toggle Board Speed on Function 0 g Toggle Board Speed on Finction 1 f Toggle Topologies on Function 0 g Toggle Topologies on Finction 1 1 Change Interrupt Coalescing Values on Port 0 m Change Interrupt Coalescing Values on Port 1 x Erase BIOS y Change Protocol Support z Change Adapters q Quit Selection Step 6 When prompted type the filename of the BIOS Fcode update The update process commences and completes in about 20 30 seconds Step 7 Exit the MPTUtil utility using the menu option q Quit 3 4 Advanced User Adjusting Default Firmware Settings Occasionally a user may find it necessary to adjust default firmware parameters set by LSI Logic during the original manufacturing process Adjustments to these parameters will affect future behavior of the Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All rights reserved LSI Logic Adapter and should be reserved for advanced users who fully understand the implications of such changes The LSI Logic firmware supports several configuration options defined individually in Section 3 4 1 Adjusting Link Speed and Section 3 4 2 Adjusting Interrupt Coalescin
40. ecture parallel SCSI host drivers can be used with the LSI Logic FC controllers with little or no additional functionality for FC 3 2 Download New FC Firmware To begin you must first download new host adapter firmware component s from the LSI Logic web site www lsilogic com Type the following address into your preferred browser http drivers silogic com The web page presents three drop down menus under Find Specific Products Make the following selections Step 1 Select Storage Adapters Step 2 Select Fibre Channel HBAs Step 3 Select LSI7202XP LC or other 2 Gbit s LSI Logic host adapter Step 4 Check the box next to BIOS Firmware Then click the Go button This search locates the latest BIOS Firmware available for your host adapter Save the file to your hard drive You may have to unzip this file Typically the download will contain three separate files FC929X ROM LSI Logic Firmware update PTBIOS ROM LSI Logic Boot BIOS update LSI9x9 ROM LSI Logic Fcode update Download New FC Firmware 3 3 Copyright 2002 2005 by LSI Logic Corporation All rights reserved These files represent updated code that you may store on your LSI Logic host adapter using one of the methods described in the next sections 3 3 Update the FC Firmware 3 3 1 The process of updating the FC firmware varies slightly depending on the operating system GUI Update Tool for Windows and Linux Platforms Wi
41. figuration Utility is a powerful tool If you disable all of your controllers while using it pressing CTRL A or 4 6 BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved CTRL E after memory initialization during reboot This allows you to re enable and reconfigure The following messages may appear during the boot process e Adapter removed from boot order parameters will be updated accordingly appears when an adapter is removed from the system or is relocated behind a PCI bridge This message is for information only and no further user action is required e Configuration data invalid saving default configuration appears if none of the information in nonvolatile random access memory NVRAM is valid This message is for information only and can occur when the BIOS is upgraded or when some external event has rendered the NVRAM temporarily unreadable e Found FC Controller not in following Boot Order List to Add Press Ctrl C to start LSI Logic Configuration Utility appears when fewer than four adapters are in the boot order and adapters exist in the system that are not in the boot order This message is for information only and indicates that more than four adapters exist in the system The additional adapters are not managed by the CU 4 7 OpenBoot BIOS LSI Logic Solaris capable Fusion MPT host adapters have Fcode resident on board allowing operation under the Sun Microsystems OpenBoot co
42. g These options may be configured using the MPTUtil utility menu as described in the subsection entitled Running the MPTUtil Program 3 4 1 Adjusting Link Speed The link speed of the LSI Logic host adapters is configurable By default the link speed is set to Auto This means the host adapter automatically detects the link speed of all other nodes on the link and automatically adjusts itself to work with those nodes If this automatic operation fails for example other nodes on a loop do not support AutoNegotiation the LSI Logic host adapters may be configured specifically to either the 2 Gbit s or 1 Gbit s speed Note The LSI7202XP LC LSI7202EP LC and LSI7202EP each have two FC ports and the LSI7402XP LC LSI7402XP LC and LSI7402XP LC each have four FC ports so the link speed must be configured for each port The LSI7102XP LC has only one port Configure the link speed of the host adapter by following these steps Step 1 To set the link speed of the host adapter execute this command from the DOS command line A MPTutil The MPTUtil program identifies all LSI Logic host adapters in the system and allows you to select which adapter to update Figure 3 4 Step 2 The MPTUtil program displays a menu of options Figure 3 5 To change the link speed on the LSI7202XP LC Port 0 lower port near the PCI connector select the following menu option f Toggle Board Speed on Function 0 To change the link speed on
43. height bracket no Hardware and Software Support The LSI Logic 2 Gbit s family of FC host adapter supports most major software operating systems such as Sun Solaris 2 6 and greater Windows Server NT 4 0 2000 XP 2003 Linux RedHat Suse Caldera Turbo NetWare and UnixWare These host adapters use the Fusion MPT architecture for all major operating systems Fusion MPT architecture offers the unique feature of having a single binary operating system driver that supports FC devices and other bus architectures Refer to the Fusion MPT Device Management User s Guide for details regarding software support for this family of host adapters Before you use any of this family of host adapters make sure your system meets the specific hardware and software requirements shown in Table 2 2 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved Table 2 2 Hardware and Software Requirements Component Requirements For Solaris SPARC hardware environments Hardware Any Sun Microsystems computer with a 3 3 V PCI slot Software Solaris 8 operating environment Firmware OpenBoot PROM version 2 1 or greater For Intel IA 32 or IA 64 hardware environments Hardware Any Intel compatible system with 3 3 V PCI slots Windows Server NT 4 0 2000 XP 2003 Software Linux Red Hat Suse Caldera Turbo NetWare and UnixWare Firmware Any Intel compatible BIOS
44. hroughput capability of 400 Mbytes s across 64 bit 66 MHz PCI both channels e Low host CPU utilization e Interrupt coalescing tunable to system requirements e Auto Topology Detection for Arbitrated Loop Fabric Loop or Direct Fabric attachment user selects N_ Port NL_Port or Auto e FC Class 3 support e FC Tape FC AL2 Class 3 confirmed delivery support e Fusion MPT common software interface e Initiator Target and FC LAN capability 3 1 2 Description 3 2 The LSIFC929X and LSIFC919X controllers operate in an environment where one or more host drivers serve as the interface layer between the operating system and the Fusion MPT services provided by the LSI Logic FC firmware The host driver is responsible for initializing the controller building request message frames issuing request message Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All rights reserved frames to the controller and processing reply message frames received from the controller The LSI Logic firmware translates Fusion MPT message frames into FC specific sequences frames and primitives that are delivered to the FC transmit and receive physical interfaces The firmware based Link Services library transparently provides all link service support that the host uses for all FC topologies The firmware also manages all link exceptions which isolates the host driver from FC unique exceptions With the Fusion MPT archit
45. hts reserved 1 2 Quick Installation Procedure 1 2 This section provides an overview of the installation procedure If you are an experienced computer user with prior host adapter installation and FC setup experience this section may describe the procedure sufficiently If you prefer more detailed guidance for installing the host adapter proceed to Section 1 3 Detailed Installation Procedure For safe and proper installation refer to the user s manual supplied with your computer and perform the following steps Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Ground yourself before removing this host adapter board Remove the host adapter from the packaging and check that it is not damaged Figure 1 1 on page 1 4 illustrates an example of this host adapter board Also refer to Chapter 2 2 Gbit s FC Host Adapter Characteristics to see more detailed drawings of the 2 Gbit s host adapter boards Open your PC cabinet and select an appropriate open PCI slot Insert the host adapter board Make any configuration changes Close your PC cabinet cover Connect the FC cable to the host adapter Installation Procedures Copyright 2002 2005 by LSI Logic Corporation All rights reserved 1 3 Detailed Installation Procedure This section provides step by step instructions for installing the host adapter If you are experienced in these tasks you may prefer to use Section 1 2 Quick Installatio
46. ion 2 8 14 LSI7402XP LC Connectors and Indicator LEDs 2 8 15 LSI7402EP LC Host Adapter Configuration 2 8 16 LSI7402EP LC Connectors and Indicator LEDs 2 8 17 LSI7402EP Host Adapter Configuration 2 8 18 LSI7402EP Connectors and Indicator LEDs Firmware Installation Procedure vi 3 1 FC Firmware Sle Features 3 1 2 Description 3 2 Download New FC Firmware 3 3 Update the FC Firmware 33 1 GUI Update Tool for Windows and Linux Platforms 3 3 2 Command Line Update Tool for Solaris Linux and Windows 333 Command Line Update Tool for DOS 3 4 Advanced User Adjusting Default Firmware Settings 3 4 1 Adjusting Link Speed 3 4 2 Adjusting Interrupt Coalescing 3 5 Troubleshooting Contents Copyright 2002 2005 by LSI Logic Corporation All rights reserved 29 2 9 2 10 2 12 2 13 2 14 2 15 2 16 zi 2 18 2 19 2 20 2 21 2 22 2 23 2 24 2 25 2 26 2 27 3 2 3 2 3 2 9 3 4 3 4 3 4 ot 3 8 3 9 3 10 3 12 Chapter 4 BIOS Features 4 1 4 2 4 3 4 4 4 5 4 6 4 7 LSI Logic Boot BIOS 4 1 1 LSI Logic Boot BIOS Features 4 1 2 BIOS Overview 4 1 3 LSI Logic BIOS Boot Specification BBS Starting the LSI Logic Boot BIOS Configuration Utility Using the LSI Logic Boot BIOS CU Main Menu 4 4 1 Adapter Properties Menu 4 4 2 Persistent ID Menu 4 4 3 Device Properties Menu 4 4 4 Boot Adapter List Menu 4 4 5 Global Properties Menu Exiting the LSI Logic Boot BIOS Configuration Utility Troubleshooting OpenBoot BIO
47. latile EEPROM on the adapter Select the port or adapter shown use the port name your system assigns ok select pci 8 700000 IntraServer fc 1 Then enter commands as shown in the following example ok show interrupt coalescing Interrupt coalescing timeout is 500 1280 decimal microseconds Interrupt coalescing depth is 9 9 decimal ok set interrupt coalescing Note The OpenBoot BIOS provides help when you enter a command that does contain the proper arguments In this case OpenBoot responds with usage is lt timeout gt lt depth gt set interrupt coalescing ok 100 8 set interrupt coalescing OpenBoot BIOS 4 13 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Interrupt coalescing timeout selected is 100 256 decimal microseconds Interrupt coalescing depth selected is 8 8 decimal Interrupt coalescing has been set Change will tak ffect after system reset Note The system must be power cycled before the changes take effect It is not sufficient to execute the reset all command 4 7 6 Set FC Link Speed 4 14 There are two modes of operation for FC 1 Gbit s and 2 Gbit s It is important to match the speed of the port with the speed of the loop or fabric to which the port is attached LSI Logic has implemented autonegotiation on the 2 Gbit s capable Fusion MPT devices If you are experiencing difficulty with the AutoNegotiate algorithm on your fabric or loop or if
48. link Maintain Logins 98 Reset FC link 99 Reset port Select an option 1 99 or 0 to quit Step 6 When prompted type the firmware file name Step 7 Type Yes when asked to continue Figure 3 3 Figure 3 3 LSIUtil File Download Enter firmware name FC929X ROM Do you want to continue Yes or No default is No Y Downloading image Download succeeded The update process requires about 20 30 seconds Upon completion the system should display this message download succeeded Step 8 Reset the adapter using option 99 or reboot to begin running the new firmware Step 9 Enter 0 to quit the program Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All rights reserved 3 3 3 Command Line Update Tool for DOS Using a DOS bootable floppy users can use a FC Flash Utility called MPTUtil to update LSI Logic adapters with new firmware Section 3 2 Download New FC Firmware page 3 3 This section provides the procedure for operating this program Note The MPTUtil program will not operate properly from a windows command window It must be run from a DOS floppy Running the MPTUtil Program Use the MPTUtil program to update the LSI Logic FC firmware on any 4 Gbit s host adapter Locate the MPTUtil exe program and FC929X ROM code on your distribution media as well as the DOS4GW exe file Copy these files to a blank formatted diskette Label it FC Firmware diskette
49. n Name Date Telephone Fax Title Department Mail Stop Company Name Street City State Zip
50. n Procedure 1 3 1 Before You Start Before starting look through the following task list to get an overall idea of the steps you will perform If you are not confident you can perform the tasks as described here LSI Logic recommends getting assistance Each FC host adapter channel that you install can act as a host for up to 126 Arbitrated Loop FC devices not including the adapter itself Follow the detailed instructions in Section 1 3 2 Installing the Host Adapter to install your host adapter board successfully 1 3 2 Installing the Host Adapter For safe and proper installation refer to the user s manual supplied with your computer and perform the following steps to install the host adapter Step 1 Ground yourself before removing this host adapter board Step 2 Remove the host adapter from the packaging and check that it is not damaged Figure 1 1 illustrates an example of this host adapter board Also refer to Chapter 2 2 Gbit s FC Host Adapter Characteristics to see more detailed drawings of the 2 Gbit s host adapter boards Step 3 Switch off the computer and unplug the power cords for all components in your system Step 4 Remove the cover from your computer according to the instructions in the user s manual for your system to access the PCI slots Caution Ground yourself by touching a metal surface before removing the cabinet top Static charges on your body can damage electronic components
51. nd bottom of the board conforms to the PCI Express Specification Revision 1 0a Figure 2 9 illustrates the major components on the LSI7202EP LC Figure 2 9 LSI7202EP LC Host Adapter Configuration LSI7202EP LC EEA LSIFC929X Port 1 SFP PCI Express Bridge 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 10 LSI7202EP LC Connectors and Indicator LEDs The LSI7202EP LC I O bracket is configured as shown in Figure 2 10 The Port 0 and Port 1 connectors provide the connections from the adapter channels to the FC subsystem The indicator LEDs indicate link status activity and link fault Figure 2 10 LSI7202EP LC Connectors and Indicator LEDs Port 1 LED Port 1 Port 0 Port 0 LED Table 2 11 describes the LSI7202EP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 11 LSI7202EP LC Link Activity Link Fault LEDs i pey o LED Appearance Green Blinking Physical Characteristics 2 19 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 11 LSI7202EP Host Adapter Configuration 2 20 The LSI Logic LSI7202EP is a dual channel 2 Gbit s FC adapter Two connectors used for I O are accessible through the module bracket The LSI7202EP uses the LSIFC929X providing two Fusion MPT channels The LS
52. nsole All basic functionality is available in an OpenBoot environment including the ability to display devices connected to the adapter and to boot devices on the adapter 4 7 1 OpenBoot BIOS Features The LSI Logic FC OpenBoot BIOS supports the following e Solaris SPARC 2 6 Solaris SPARC 2 7 and Solaris 8 Open Firmware environments e Root Boot device selection from any target device e Standard command line interface with help query e Configuration options and selection capability for each host adapter OpenBoot BIOS 4 7 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 7 2 4 8 Identifying the FC Devices The probe scsi all command identifies the FC devices on your Fusion MPT adapter To show all disks available from the OpenBoot prompt use the probe scsi all command Note that this command is used regardless of whether the disks are FC or SCSI All disks available on all Fusion MPT devices are displayed The following example shows the kind of information that is displayed when you enter this command ok probe scsi all pcik8 600000 SUNW qlc 4 LiD HA LUN Port WWN Disk description 1 1 0 2100002037e4d65b SEAGATE ST318304FSUN18G 0726 pci 8 700000 IntraServer Ultral60 scsi 3 1 pci 8 700000 IntraServer Ultral60 scsi 3 Target 0 Unit 0 Disk IBM DDRS 34560D DC1B pci 8 700000 IntraServer fc 2 A PT Version 1 00 Firmware Version 1 02 00
53. o types of BIOS are available for the LSI Logic host adapters e LSI Logic FC boot BIOS for Intel AMD based platforms and e LSI Logic FC OpenBoot BIOS for Solaris SPARC platforms Both the LSI Logic boot BIOS and OpenBoot BIOS are stored on the FC host adapter boards 2 Gbit s Fibre Channel Host Adapters User s Guide 4 1 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 1 LSI Logic Boot BIOS This section provides the features description and installation of the LSI Logic FC boot BIOS 4 1 1 LSI Logic Boot BIOS Features The LSI Logic FC boot BIOS supports e Selection and configuration for up to 256 adapters e Boot device selection from any four host adapters e Automatic INT13 drive mapping for FC drives 4 1 2 BIOS Overview If Boot is enabled the boot BIOS scans for FC Hard disks connected to the FC host adapter All discovered disks are enumerated with drive letters and appended to a master list of disks discovered on the host Upon scan completion the host serially inspects the master list of disks beginning with drive letter A and attempts to boot from the first device it finds with a boot record If boot from FC is desired you may elect to remove or disable IDE drives as these tend to get lower drive letter assignments than FC devices Note The Boot feature is disabled by default on all host adapters shipped from LSI Logic 4 1 3 LSI Logic BIOS Boot Specification BBS The LSI Logic BI
54. onment 2 4 1 Use the LSI Logic 2 Gbit s family of FC host adapters in PCI X or PCI Express computer systems with an Industry Standard Architecture Extended Industry Standard Architecture ISA EISA bracket type The LSI Logic supplied FC BIOS and firmware operate the host adapters An on board flash memory device and a serial EEPROM are provided to allow BIOS code and OpenBoot code support over the PCI bus PCI X Interface The PCI X interface operates as a 64 bit DMA bus master The edge connector makes the PCI X connection which provides connections on both the front and back of the board The signal definitions and pin numbers conform to the PCI X 133 Specification Revision 1 0a Refer to that specification for details regarding the signal assignments 2 4 2 PCI Express Interface 2 6 The LSI Logic PCI Express interface operates as a x8 lane DMA bus master The narrow edge connector makes the PCI Express connection which provides connections on both the front and back of the board The signal definitions and pin numbers conform to the PCI Express base Specification Revision 1 0a Refer to that specification for details regarding the signal assignments 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 4 3 FC Interface The FC interface varies depending on which LSI Logic 2 Gbit s host adapter you have selected Refer to Section 2 8 Physical Characteristics
55. or provides the connection from the adapter channel to the FC subsystem The indicator LED indicates link status activity and link fault Figure 2 4 LSI7102LXP LC Connector and Indicator LED Port 0 Port 0 LED Table 2 8 describes the LSI7102LXP LC Link Activity Link Fault LED appearance that indicates a valid link presence of link activity or a fault on the link Table 2 8 LSI7102LXP LC Link Activity Link Fault LEDs bin powy Fat J LED Appearance Green Blinking Physical Characteristics 2 13 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 8 5 LSI7202XP LC Host Adapter Configuration The LSI Logic LSI7202XP LC is a dual channel 2 Gbit s FC adapter Two LC optical connectors used for I O are accessible through the module bracket The LSI7202XP LC uses the LSIFC929X providing two Fusion MPT channels The LSI7202XP LC is a PCI short card the dimensions are 6 625 inches x 2 53 inches The external FC connections are made through the 2 Gbit s SFP optical modules The component height on the top and bottom of the board conforms to the PCI X 133 Specification Revision 1 0a Figure 2 5 illustrates the major components on the LSI7202XP LC Figure 2 5 LSI7202XP LC Host Adapter Configuration LSI7202XP LC TEEPE EEE LSIFC929X Voltage Regulator 2 14 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation
56. rights reserved Step 2 Open a terminal window and open the directory containing the LSIUtil program Step 3 Execute the LSIUtil program Step 4 Select a device to update Figure 3 1 Figure 3 1 LSIUtil Device Selection root lsiutil LSI Logic MPT Configuration Utility Version 1 28 November 12 2004 2 MPT Ports found Port Name Chip Vendor Type MPT Rev Firmware Rev 1 proc mpt iocd LSI Logic FC929X 103 01021200 2 proc mpt iocl LSI Logic FC929X 103 01021200 Select a device 1 2 or 0 to quit Step 5 From the subsequent displayed list select option menu 2 or 4 as shown Figure 3 2 Update the FC Firmware 3 5 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 3 6 Figure 3 2 LSIUtil Download Options 1 Identify firmware BIOS and or FCode 2 Download firnnyare update the FLASH 3 Upload firmware 4 Download BIOS and or FCode update the FLASH 5 Upload BIOS and or FCode Download SEEPROM Upload SEEPROM Scan for devices Read change configuration pages 10 Change IOC settings interrupt coalescing 13 Change FC Port settings 14 Change enable disable multi pathing 15 Change persistent mappings 16 Displaylogged in devices 17 Show port aliases 19 Test configuration page actions 20 Diagnostics 21 RAID actions 22 Reset bus 23 Reset target 80 Set port offline 81 Set port online 94 Send GID_FT 95 Send GA_ NXT 96 Send ELS 97 Reset FC
57. system 2 2 Features This section provides an overview of the PCI X Interface the PCI Express Interface and the FC Interface for the 2 Gbit s family of host adapters 2 2 1 PCI X Interface PCI X interfaces I O components to the processor and memory subsystems in equipment ranging from PCs to servers The PCI X interface operates as a 64 bit DMA bus master capable of 64 bit addressing The PCI X interface includes the following features e Full 64 bit DMA bus master e LSIFC929X LSIFC919X functionality Zero wait state bus master data bursts up to 1 Kbyte Host adapters comply with PCI Local Bus Specification Rev 2 2 3 3 V interface e Serial EEPROM configuration storage e Host adapters comply with PCI X 133 Local Bus Specification Rev 1 0a Features 2 3 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 2 2 2 PCI Express Interface The PCI Express launched in 2002 interface is a new serial I O interface standard being used in next generation computer storage and communications platforms This scalable interface allows vendors to choose the number of 2 5 Gbit serial lanes two to 16 most suitable to their product design and application need The PCI Express interface featured on the LSI Logic Fibre to PCI Express boards includes e 8 serial I O lanes 2 5 GHz full duplex e Fully PCl compatible software model e Serial EEPROM configuration storage 2 2 3 FC Interface The LSIFC929X
58. t also provides access to the device settings of a host adapter To display this menu select a device under the Adapter field on the Main menu and press ENTER 4 4 2 Persistent ID Menu 4 4 You can use the Persistent ID menu simply to review the automatic mapping between a drive World Wide Name WWN and its assigned logical SCSI bus and Target ID The screen also can force a drive to a specific logical Target ID Selecting Add WWN at an unused location clears out the associated WWN DID field and allows you to enter the first 16 characters of the WWN Pressing ENTER afterwards allows the last 16 characters to be entered The Configuration Utility automatically adds any leading zeros if necessary If an entry was put in by mistake selecting Erase on the appropriate line removes the entry Logical ID selection defaults to be the lowest ID available This can be changed by using the PLUS or MINUS keys to cycle the numbers The Bus field always defaults to 0 and cannot be changed It is displayed whenever an outside utility has reserved a different number The Next Page and Previous Page options are provided on the persistent ID screens through the F2 key which moves the screen forward or back by 16 entries However the CU requires storing any modifications to the BIOS Features Copyright 2002 2005 by LSI Logic Corporation All rights reserved current page before new entries may be viewed or modified A pop up confirmation window
59. t the system devices You should see an output similar to the following ok show devs SUNW UltraSPARC III 0 0 virtual memory memory m0 0 aliases options openprom chosen packages OpenBoot BIOS 4 9 Copyright 2002 2005 by LSI Logic Corporation All rights reserved upa pei pci pci pci pci pci pci pci pei pci pci ok 8 480000 S 8 700000 I 8 700000 I 8 700000 I 8 700000 I 8 700000 I 8 700000 I 8 700000 I 8 700000 I 8 700000 I n n n n n n n n gi UNW b 0 0 raServer fc raServer fc raServer fc raServer fc raServer fc raServer fc raServer fc raServer fc raServer fc 8 700000 scsi 6 1 tape 8 700000 scsi 6 1 disk e 6 pci 8 700000 IntraServer fc 1 identifies the first FC interface on an LSIFC929X based adapter e 6 pci 8 700000 IntraServer fc 1 1 identifies the second FC interface on an LSIFC929X based adapter 2 1 1 1 2 disk 2 tape 1 1 disk 1 1 tape 1 disk 1 tape e An LSIFC919X based adapter shows only one such FC device Note The above listing is an example The show devs output may vary depending on your system and configuration Use the corresponding entries on your system not the ones given here If these devices are not listed check to assure that the adapter is correctly installed and reseat the adapter in the PCI slot if necessary 4 7 4 Adapter Specific
60. t to change and use the PLUS or MINUS key to raise or lower the boot order respectively Main Menu 4 5 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 4 4 5 Global Properties Menu The Global Properties menu allows you to pause if an alert message has been displayed to view display boot information and to set display and video modes 4 5 Exiting the LSI Logic Boot BIOS Configuration Utility The Exit menu for the LSI Logic boot BIOS configuration utility is used for all six of the menus listed in Section 4 4 Main Menu page 4 3 However the available functionality is different for the Main menu and the five subordinate menus To exit from the Adapter Properties Persistent ID Device Properties Boot Adapter List or Global Properties menus use the following exit options Cancel exit Returns you to the previous menu Save changes then Implements any changes you made on the previous exit this menu menu and returns you to the Main menu Discard changes Restores the default settings and returns you to the then exit this menu Main menu To exit from the Main menu use the following exit options Cancel exit Returns you to the Main menu Exit the Configuration Exits the configuration and automatically reboots your Utility system Important If you reboot the system without properly exiting from this utility some changes may not take effect 4 6 Troubleshooting The LSI Logic boot BIOS Con
61. tem configurations Consult LSI Logic Host Adapter Support to verify the need to disable Interrupt Coalescing for specific system configurations When enabled two parameters are relevant for interrupt coalescing Coalescing Depth Specifies the number of I Os that must complete before a host interrupt is generated For example if set to 4 then the adapter waits until four I Os complete before notifying the host CPU via the interrupt mechanism You can decrease this value to improve system performance if the system contains lower performance servers and or peripherals Coalescing Timeout This is failsafe time period that specifies the maximum amount of time in milliseconds to interrupt regardless of Coalescing depth Advanced User Adjusting Default Firmware Settings 3 11 Copyright 2002 2005 by LSI Logic Corporation All rights reserved 3 5 Troubleshooting Some potential problems and their suggested solutions are as follows The firmware and BIOS revisions typically must be in sync for proper operation Check with LSI Logic Technical Support to make sure that the Firmware is the correct version to use with your BIOS If the firmware revision is not in sync with the BIOS revision system failures may occur How do you identify the version number of the firmware The UNIX compatible WHAT EXE program for DOS included on your distribution media can identify the ROM files on the diskette s Examples what
62. ters are all available with optical or copper interconnects No host adapter configuration is necessary 2 8 1 LSI7102XP LC Host Adapter Configuration The LSI Logic LSI7102XP LC is a single channel 2 Gbit s FC adapter One LC optical connector is used for I O which is accessible through the module bracket The LSI7102XP LC host adapter uses the LSIFC919X processor providing one Fusion MPT channel The LSI7102XP LC is a PCI short card the dimensions are 6 625 inches x 2 53 inches The external FC connections are made through a 2 Gbit s SFP optical module The component height on the top and bottom of the board conforms to the PCI X 133 Specification Revision 1 0a Figure 2 1 illustrates the major components on the LSI7102XP LC Unique World Wide Name 2 9 Copyright 2002 2005 by LSI Logic Corporation All rights reserved Figure 2 1 LSI7102XP LC Host Adapter Configuration LSI7102XP LC HEE ETE LSIFC919X Port 0 SFP LS SS Se 2 8 2 LSI7102XP LC Connector and Indicator LED 2 10 The LSI7102XP LC I O bracket is configured as shown in Figure 2 2 The LC connector provides the connection from the adapter channel to the FC subsystem The indicator LED indicates link status activity and link fault 2 Gbit s FC Host Adapter Characteristics Copyright 2002 2005 by LSI Logic Corporation All rights reserved Figure 2 2 LSI7102XP LC Connector and Indicator LED Port 0
63. th quick and detailed installation instructions e Chapter 2 2 Gbit s FC Host Adapter Characteristics describes the physical and operational environments of the host adapters e Chapter 3 Firmware Installation Procedure describes the installation and configuration procedures for the Fusion MPT and Fibre Channel drivers e Chapter 4 BIOS Features describes the installation procedures for the Fibre Channel BIOS and Configuration Utility 2 Gbit s Fibre Channel Host Adapters User s Guide iii Copyright 2002 2005 by LSI Logic Corporation All rights reserved Related Publications LSIFC929X Dual Channel Fibre Channel I O Processor Technical Manual Document No DB14 000202 01 LSIFC919X Single Channel Fibre Channel I O Processor Technical Manual Document No DB15 000225 01 Fusion MPT Device Management User s Guide Volume 1 2 Document No DB15 000186 01 PCI Local Bus Specification Rev 2 2 PCI X 133 Local Bus Specification Rev 1 0a PCI Express Base Specification Rev 1 0a Revision Record Revision Remarks Preliminary release Final release Updated to add the LSI7102LXP LC LSI7202LXP LC LSI7202EP LSI7202EP LC LSI7402EP and LSI7402EP LC iv Preface Copyright 2002 2005 by LSI Logic Corporation All rights reserved Contents Chapier 1 Installation Procedures 1 1 General Description 1 2 Quick Installation Procedure 1 3 Detailed Installation Procedure 134 Before You Start
64. th the MyStorage management software installed on either Windows or Linux operating systems you can use the MyStorage software to update LSI Logic host adapters with new firmware Section 3 2 Download New FC Firmware The CD ROM media distributed with many LSI Logic host adapter kits contains the MyStorage software alternatively users can download the MyStorage software from the LSI Logic web site www I silogic com Refer to LSI Logic MyStorage Management Software User s Guide for detailed usage instructions 3 3 2 Command Line Update Tool for Solaris Linux and Windows 3 4 LSI Logic provides a FC Flash command line utility called LSIUtil to update LSI Logic host adapters with new firmware Section 3 2 The software is available for the Windows Linux and Solaris operating systems This section provides the procedure for operating this program Note The LSIUtil program will not operate properly unless an LSI Logic OS driver is also installed Running the LSIUtil Program The LSIUtil program may be used to update the LSI Logic FC firmware of any 2 Gbit s host adapter Locate and copy the LSIUtil exe program and the FcC929X ROM code files to a directory on your hard drive To update the firmware complete the following steps Step 1 Ensure that the host adapter is properly installed in the system PCI PCI X or PCI Express slot Firmware Installation Procedure Copyright 2002 2005 by LSI Logic Corporation All
Download Pdf Manuals
Related Search
Related Contents
View Data and Installation Sheet Here Samsung RS25KLAT 用戶手冊 取扱説明書 Massive Wall light 17203/31/10 Manual de instalação para sifões シード 2weekFine UV(PDF:2.3MB) Megapixel Indoor Fixed IPC User`s Manual V2.1 201106 revised TESTConnect Plus ` sort du brouillard - Les services de l`État dans le Haut-Rhin Copyright © All rights reserved.