Home
Linn Klimax Kontrol Preamplifier Stereo Amplifier User Manual
Contents
1. KLIMAX TWIN power amplifiers and in partnership with them positions KLIMAX as a family of products that are without parallel in terms of sound performance and engineering quality Each KLIMAX KONTROL preamplifier is unique in its manufacture The casing of the product is precision machined from two solid sections of aluminium alloy Due to the highest quality of machined finishes it is often possible to see the grain of the casing This grain is part of the aluminium alloy s structure and is indicative of an exceptional and individual product finished to the highest standard The distinctive product casework also serves to protect and stabilise the internal electronics as well as forming the heat exchanger to dissipate any heat generated by the preamplifier circuitry All KLIMAX products have been designed to be internally compact This reflects our desire to keep the audio signal path as short and simple as possible Applying this approach rigorously results in high density circuitry that generates and receives the absolute minimum level of electrical noise As with other products in the KLIMAX range the KLIMAX KONTROL preamplifier exemplifies Linn s unremitting commitment to exploiting the latest technology in order to produce ever better sounding products The unit s features include Linn s switch mode power supply and both balanced and unbalanced inputs and outputs We designed this product without compromise in order to bring you as close as
2. Instructions eS e 6a 10 11 12 13 14 15 16 17 18 19 20 Read instructions Read the safety and operating instructions before operating the appliance Retain instructions Retain the safety and operating instructions for future reference Heed warnings Observe all warnings on the appliance and in the operating instructions Follow instructions Follow all operating and use instructions Water and moisture Do not use the appliance near water for example near bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like Carts and stands Use only with a cart or stand that is recommended by the manufacturer An appliance and cart combination should be used with care Quick stops excessive force and uneven surfaces may cause the appliance and cart combination to overturn Wall or ceiling mounting Mount to a wall or ceiling only as recommended by the manufacturer Ventilation Site the appliance so that its location or position does not interfere with its proper ventilation For example the appliance should not be situated on bed sofa rug or similar surface that may block the ventilation openings or placed in a built in installation such as a bookcase or cabinet that may impede the flow of air through the ventilation openings Heat Site the appliance away from heat sources such as radiators heaters stoves or other appliances including amplifiers tha
3. USA see article 810 of the National Electrical Code ANSI NFPA 70 concerning installation requirements Lightning storms Unplug this apparatus during lightning storms or when unused for long periods of time Objects and liquid entry Do not let objects or liquids fall into the product Do not expose the product to dripping or splashing Do not place a vessel containing liquid on top of the product Damage requiring service The product should be serviced by qualified personnel if a The power cord or plug has been damaged b Objects or liquid have fallen into the product C The product has been exposed to rain d The product does not appear to operate normally or exhibits a marked change in operation e The product has been dropped or the enclosure damaged Servicing Do not attempt to service the product beyond that described in the operating instructions All other servicing should be referred to qualified service personnel 21 UK users please read this important safety information Replacing the fuse in the mains plug This appliance is fitted with a non rewireable 13 Amp mains plug The plug contains a 5 Amp fuse If the fuse has blown it can be replaced as follows a Pull out the red fuse cover carrier b Remove and dispose of the blown fuse c Fitanew 5 Amp BS1362 approved fuse into the carrier and push the carrier back into the plug Always ensure the fuse cover Is fitted If the fuse cover is missing do not use the plug Co
4. uk 19 Explanation of symbols used in this manual and on the product dangerous voltages within the enclosure of sufficient magnitude to This symbol is intended to alert the user to the presence of uninsulated IN cause electric shock This symbol is intended to alert the user to the presence of important maintenance and servicing information in the instruction and service manuals CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE CORRECT TYPE OF FUSE DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE WARNING SHOCK HAZARD DO NOT OPEN TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE THIS APPLIANCE MUST BE EARTHED MAINS PLUGS This appliance is supplied with a non rewireable mains plug for the intended country Replacement mains leads can be obtained from your Linn retailer Should you need to change the plug please dispose of it carefully A plug with bared conductors is dangerous if engaged in a live socket The Brown wire must be connected to the Live Line supply pin The Blue wire must be connected to the Neutral supply pin The Green Yellow wire must be connected to the Earth Ground supply pin Please contact your retailer or a competent electrician if you are in any doubt 20 General Safety
5. LINN Klimax Kontrol Owner s Manual English Copyright Linn Products Limited First edition September 2002 Linn Products Limited Floors Road Waterfoot Glasgow G76 OEP Scotland United Kingdom All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of the publisher Printed in the United Kingdom KLIMAX KONTROL Linn and the Linn logo are trade marks of Linn Products Limited The information in this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by Linn Products Limited Linn Products Limited assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual Introduction Unpacking Voltage selection Cleaning Back Panel Front Panel Handset Source Setup Operation Product Lock User Options Technical Specification Guarantee and Service Important Safety Information General safety instructions UK users CE Declaration of Conformity amp FCC Notice 12 13 14 17 18 20 21 22 23 Dear Customer Linn s KLIMAX KONTROL is a two channel preamplifier designed for use in high performance multi amplifier and multi channel audio and audio video systems The KLIMAX KONTROL follows Linn s KLIMAX SOLO and
6. ME To store settings and exit user options mode B Press STANDBY The available user options are detailed in the following table Defaults are shown in bold User Option SLEEP DISPLAY SLEEP TIME INPUT 1 STARTUP SOURCE STARTUP VOLUME DEFAULT VOLUME Description The display on the front panel when the unit Is in sleep mode The time between the audio signal ceasing and the unit entering sleep mode Signal type for input 1 Source the unit is in when brought out of standby Volume level the unit is in when brought out of standby Volume level the unit selects when brought out of standby if STARTUP VOLUME above is set to DEFAULT 14 Possible settings VOLUME LOGO SOURCE NOTHING 2s 55 105 20s NEVER BALANCED UNBALANCED INPUT 1 LAST SOURCE INPUTS 2 5 DEFAULT LAST SOURCE 50 40dB 0 co to 100 10dB User Option Description Possible settings MAX VOLUME Upper limit on the volume control 100 10dB 0 co to 100 10dB BINDING If set to GLOBAL the same volume and balance GLOBAL PER SOURCE settings are used for each source If set to PER SOURCE separate volume and balance settings are allowed for each source PRODUCT IR Enables or disables the infra red receiver on the ENABLED DISABLED front of the unit REMOTE IR Allows you to specify which remote infra red device RCU NOTHING MOGEYE the unit responds to or disables operation of the unit via a remote in
7. NN KLIMAX KLIMAX KEON TER SOURCE SETUP 3 Myre PH2 CINN KOLOM A KONTROL 4 Change the source type Select the source type to match the name of the key on the handset you wish to use You can select a source type more than once if you have more than one device of the same type e g two CD players connected to the KLIMAX KONTROL To display the next previous source type Press VOLUME VOLUME SETUP 3 Possible source types for setups 1 to 4 are CD PH1 PH2 TUN TAPE 1 TYPE TUN TAPE 2 AUX1 NONE Possible source types for setup 5 are KNEKT NONE 5 Changethe name for the source You are able to give the source a name which will be shown on the display when that source is selected SOURCE SETUP 3 INPUT 3 Press SOURCE on the front panel or BAL L on the handset The display shows the current name for the source with the first character flashing To change the character Repeatedly press or hold VOLUME VOLUME to cycle forwards backwards through the characters The following characters are available to Z 0 to 9 space To move to the next character Press MUTE Note The name can be up to eight characters long For any source setups you are not using select NONE 6 Change the volume offset for the source Volume offset is for adjusting the volume of a source in comparison to other sources You may
8. ced xlr output LEFT IN 1 balanced xlr input LEFT IN 2 unbalanced input LEFT IN 3 unbalanced input LEFT IN 4 unbalanced input 13 14 115 116 17 A 9 00 11 BALANCED LEFT IN 2 LEFT IN 3 LEFT IN 4 LEFT IN 1 LEFT OUT 5232 VOLTAGE RANGE e IN 400 240V 50 60Hz 800 RS232 OUTPUT INPUT for operation of this product via computer or touch screen interface RC5 OUT for control of this product in a KNEKT system KNEKT IN input for use in KNEKT system RCU KNEKT Room Control Unit input RC5 IN for control of this product in a KNEKT system MAINS INPUT global mains input 100V to 240V mode then disconnected from the mains supply before connecting or disconnecting any of the plugs on the back panel If this is not done you may generate surges which could damage the KLIMAX KONTROL or other components in your audio AV system The KLIMAX KONTROL should be put into standby STANDBY SOURCE VOLUME 9 99 Front panel display source wur m stanoey co PH 1 PH 2 TUN TAPE 1 TAPE 2 AUX 1 Source selection keys BALL BAL R Balance adjustment PH 2 TUN TAPE 1 TAPE2 REPORT MONO RECORD See Product Lock page 13 BALL LINN HI FI PERSONAL HANDSET 3 mono u MUTE LI
9. erence by one or more of the following measures Reorient or relocate the receiving antenna ncrease the separation between the equipment and receiver Connectthe equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 23
10. es set to No If unity gain is set to Yes for a source other than an AV processor the volume level from your KLIMAX KONTROL will be very high non adjustable and could damage your loudspeakers Press SOURCE or BALL again The display shows whether unity gain for the currently selected source is on Yes or off No change the unity gain setting B Press VOLUME 9 Exit source setup mode To save your adjustments and exit source setup mode B Press STANDBY Note If you wish to reset the KLIMAX KONTROL to the original settings configured by the installer enter user options mode and select YES for the INSTALLER SETUP option see User Options page 15 11 _ This section provides general operating instructions for the KLIMAX KONTROL Standby mode To exit or enter standby mode B Press STANDBY Source selection Handset To switch source Press the key for the appropriate source e g CD Note If you have used a source type more than once see Source Setup page 9 repeatedly press the appropriate source key to cycle through the available sources Front panel To switch source Repeatedly press or hold SOURCE SOURCE until the desired source is shown on the front panel display Volume To adjust the volume Repeatedly press or hold VOLUME VOLUME Volume range is from 0 to 100 in 200 x 0 5 steps Muting To mute or unmute a source Press MUTE Balance Handse
11. fra red device UNITS Units in which volume level is displayed NUMERICAL dB LOGO The graphics used as the logo in the SLEEP DISPLAY Linn logo musical notes option KEY RATE Rate at which volume changes when VOLUME 21 range 1 slowest to 40 keys are held fastest MUTE RATE Rate at which volume mutes unmutes when 3 range 1 slowest to 10 switching sources or muting unmuting fastest BRIGHTNESS Brightness of front panel display 15 range 0 dimmest to 15 brightest RS232 CONNECTION Enables or disables the RS232 circuitry ENABLED DISABLED DEVICE ADDRESS Which RC5 addresses the unit will respond to HANDSET 0x10 0x13 INSTALLER SETUP reset the unit to the settings defined by the NO YES installer when the unit was first configured set to YES FACTORY SETUP reset the unit to the settings defined at NO YES only appears if installer manufacture i e the defaults shown in the settings have been altered right hand column and a blank set of source Setups set to YES fsetto YES the unit will display names given to sources during initial source setup To reset the factory defaults you must first reset the installer settings set INSTALLER SETUP option to YES then exit and re enter user options mode 15 fus Lt Sa WES ne C sii m 16 General Audio inputs Gain range Audio outputs Dimen
12. nd should be stamped by your retailer and returned to Linn as soon as possible WARNING Unauthorised servicing or dismantling of the product invalidates the manufacturer s warranty There are user serviceable parts inside the product and all enquiries relating to product servicing should be referred to authorised retailers only Technical support and information For technical support product queries and information please contact either your local retailer or one of the Linn offices opposite Full details of your local retailer distributor can be found on the Linn web site www linn co uk IMPORTANT Please keep a copy of the sales receipt to establish the purchase date of the product Please ensure that your equipment is insured by you during any transit or shipment for repair 18 _ _GuarentecondService Linn Products Limited Floors Road Waterfoot Glasgow G76 OEP Scotland UK Phone 44 0 141 307 7777 Fax 44 0 141 644 4262 Helpline 0500 888909 Email helpline linn co uk Website http www linn co uk Linn Incorporated 8787 Perimeter Park Boulevard Jacksonville FL 32216 USA Phone 1 904 645 5242 Fax 1 904 645 7275 Helpline 888 671 LINN Email helpline linninc com Website http www linninc com Linn Deutschland GmbH Albert Einstein Ring 19 22761 Hamburg Deutschland Phone 49 0 40 890 660 0 Fax 49 0 40 890 660 29 Email info linngmbh de Website http www linn co
13. neral requirements Marking Hazardous radiation Heating under normal conditions Shock hazards under normal operating conditions Insulation requirements Fault conditions Mechanical strength Parts connected to the mains supply Components Terminal devices External flexible cords Electrical connections and mechanical fixings Protection against electric shock Stability and mechanical hazards Resistance to fire The conformity of the designated product with the provisions of Directive number 89 336 EEC EMC is proved by full compliance with the following standards Standard number Date of issue Test type EN55013 2001 Conducted emissions EN55013 2001 Absorbed emissions EN55020 2002 Immunity FCC Notice NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interf
14. ntact your Linn retailer to obtain a replacement fuse cover Fuses are for fire protection and do not protect against electric shock Mains plug replacement Should your mains plug need replacing and you are competent to do this proceed as follows If you are in doubt contact your Linn retailer or a competent electrician a Disconnect the plug from the mains supply b Cut off the plug and dispose of it safely A plug with bared conductors is dangerous if engaged in a live socket Only fit a 13 Amp BS1363A approved plug with a 5 Amp fuse d The cable wire colours or a letter will be marked at the connection points of most quality plugs Attach the wires securely to their respective points The Brown wire must go to the Live pin the Blue wire must go to the Neutral pin and the Green Yellow wire must go to the Earth pin e Before replacing the plug top ensure that the cable restraint is holding the outer sheath of the cable firmly and that the wires are correctly connected WARNING THIS APPLIANCE MUST BE EARTHED 22 CE Declaration of Conformity Linn Products Ltd declare that this product is in conformance with the Low Voltage Directive 73 23 EEC and Electromagnetic Compatibility 89 336 EEC as amended by 92 31 EEC and 93 68 EEC The conformity of the designated product with the provisions of Directive number 73 23 EEC LVD is proved by full compliance with the following standards Standard number Date of issue Test type EN60065 1998 Ge
15. possible to the music you love We are certain that it will bring you a great deal of pleasure and satisfaction both now and in the years to come ET Pm S Yours faithfully a Pu p ae The KLIMAX Design Team ud p Ah yes Unpacking The KLIMAX KONTROL is supplied with the following accessories mains lead B handset silver interconnects warranty card B this manual We recommend that you retain all packaging in case you need to transport the unit at a later date Voltage Selection The KLIMAX KONTROL contains an automatic internal mains voltage switch This switch operates on all worldwide mains voltages from 100V to 240V Manual adjustment on the product for setting the input mains voltage is not possible This unit must be earthed Use the earthed moulded mains lead supplied Never use an unearthed plug or adaptor Cleaning Disconnect the KLIMAX KONTROL preamplifier from the power supply before cleaning Remove dust and fingerprints with a soft dry cloth Avoid using domestic cleaning products on the unit RIGHT IN 4 RIGHTIN3 RIGHTIN 2 BALANCED RIGHT IN 1 RIGHT OUT WARNING THIS APPARATUS MUST BE EARTHED RIGHT IN 4 unbalanced input RIGHT IN 3 unbalanced input 14 RIGHT IN 2 unbalanced input 15 RIGHT IN 1 balanced xlr input 16 RIGHT OUT balanced xlr output RIGHT OUT unbalanced output LEFT OUT unbalanced output LEFT OUT balan
16. sions Weight Power consumption Mains supply fuse Mains supply range Impedance unbalanced Signal unbalanced Impedance balanced Signal balanced Common mode rejection ratio Minimum to maximum Impedance unbalanced Signal unbalanced Impedance balanced Signal balanced Frequency response Distortion harmonic Noise floor Cross talk channel to channel Cross talk source to source Noise measurement Dynamic range 60mm H x 350mm W x 355mm D 9kg 15W 100V to 240V AC T800mA anti surge 100V to 240V AC nominal 10kQ OdBV nominal 15dBV maximum 7 8kQ 6dBV nominal 20dBV maximum 70dB 1kHz OdBV 95 54 to 9 5dB in 0 5dB steps 3000 15dBV maximum 8V peak 600 15dBV maximum 8V peak 2 3Hz to 200kHz 0 002596 1kHz 9 OdBV Less than 100dBV 116dBv 116dBv 123dBV 1kHz V1Hz 115dB 17 This product is guaranteed under the conditions which apply in the country of purchase and your statutory rights are not limited In addition to any statutory rights you may have Linn undertake to replace any parts which have failed due to faulty manufacture To help us please ask your Linn retailer about the Linn warranty scheme in operation in your country In parts of Europe the United States of America and some other markets extended warranty may be available to customers who register their purchase with Linn A warranty registration card is included with the product a
17. t produce heat Power sources Connect the appliance to a power supply only of the type described in the operating instructions or marked on the appliance Grounding or polarisation Do not defeat the safety purpose of the polarised or grounding type plug A polarised plug has two blades with one wider than the other A grounding type plug hastwo blades and a third grounding prong The wide blade orthe third prong is provided for your safety When the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Power cord protection Route power cords so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs power sockets and at the point where they exit from the appliance Protective attachment plug As a safety feature the product is equipped with an attachment plug containing overload protection See the instruction manual about resetting or replacing the plug Should the plug need replacing ensure that a replacement is used which has the same overload protection as the original Cleaning The product should be cleaned only as recommended by the manufacturer Power lines An outdoor antenna should be located away from power lines Outdoor antenna grounding If an outdoor antenna is connected to the tuner receiver ensure that the antenna system is grounded to provide some protection against voltage surges and static build up In the
18. t only To adjust the balance Repeatedly press or hold BALL BAL Balance range is from 15 increments to the left to 15 increments to the right Stereo mono switching Handset only To toggle between stereo or mono output Press MONO 12 ProductLock ccs OoOO The product lock prevents any changes being made to the KLIMAX KONTROL entering standby changing the volume or source etc while it is powered up i e when it is not in standby mode Note To turn the product lock on the unit must be powered up To turn the product lock on B Hold MUTE on the front panel or handset until the display shows LOCK B While LOCK is displayed press RECORD on the handset The display changes to KEY LOCKED The product lock is now on To turn the product lock off B Hold MUTE on the front panel or handset for approximately 12 seconds until the display shows UNLOCK B While UNLOCK is displayed press RECORD on the handset The product lock is now off 13 This section explains how you can configure certain features of the KLIMAX KONTROL to suit your requirements Note The unit must be in standby mode To enter user options mode B Hold STANDBY until the front panel display shows SLEEP DISPLAY To cycle through the user options Repeatedly press or hold SOURCE SOURCE on the front panel or BALR BALL on the handset To adjust the setting of an option Repeatedly press VOLUME VOLU
19. want to adjust the volume offset for a source if for example your tuner sounds quieter than your CD player when played at the same volume setting Press SOURCE or BALL again The display shows the volume offset for the source SOURCE SETUP 3 VOLUME 0 To increase decrease the volume offset for this source Repeatedly press or hold VOLUME VOLUME Volume offset range Is from 10 lowest setting to 10 highest setting in 40 x 0 5 steps with no volume offset being 0 7 Change the balance offset for the source Balance offset is for adjusting the balance of a source in comparison to other sources You may want to adjust the balance offset for a source if for example your tuner sounds louder through the left channel than it does through the right Press SOURCE or BALL again The display shows the balance offset for the currently selected source SOURCE SETUP 3 dE To shift the balance offset to the right Repeatedly press VOLUME To shift the balance offset to the left Repeatedly press VOLUME Balance offset range is from 5 increments to the left to 5 increments to the right 10 8 Change the unity gain for the source The unity gain setting lets you use the KLIMAX KONTROL in a multi channel AV system If you are setting up an AV processor as one of your sources and the front speakers are going to be channelled through the KLIMAX KONTROL set unity gain to Yes In all other cas
Download Pdf Manuals
Related Search
Related Contents
Netgear RANGEMAX WAG302 User's Manual CAOUTCHOUC LIQUIDE Montamateriales (Luis Mª Recacoechea Olabarria) SV-AT18 User Manual Untitled Kenroy Home 91701CH Installation Guide カタログ (pdf形式、331.89KByte) Avaya Octel 200 Server User Manual Flo-tech PFM6 Digital Portable Hydraulic Tester Manual Copyright © All rights reserved.
Failed to retrieve file