Home
Leviton Scene Capable Electronic Switch Switch User Manual
Contents
1. WIRING COORDINATING REMOTE Connect wires per WIRING DIAGRAM as follows NOTE BK and RD terminals on coordinating remote are unused Tighten both screws NOTE Maximum wire length from switch to last remote is 300 ft 90 m e Green or bare copper wire in wall box to Green terminal screw e Load wall box wire identified tagged when removing old switch to First Traveler note color as above e Second Traveler wall box wire note color as above to terminal screw marked YL RD This traveler from the remote must go to the terminal screw on the switch marked YL RD e Remove White insulating label from terminal screw marked WH e Line Neutral wall box wire to terminal screw marked WH e Proceed to Step 5 Step 5 e Position all wires to provide room in outlet wall box for device e Ensure that the word TOP is facing up on device strap e Partially screw in mounting screws in wall box mounting holes NOTE Dress wires with a bend as shown in diagram in order to relieve stress when mounting device Testing your Switch prior to mounting in wall box e Restore power at circuit breaker or fuse e Press pad until locator light is OFF Lights should turn ON If lights do not turn ON refer to the TROUBLESHOOTING section Step 6 Including Switch into Z Wave Network NOTES e f using a non Leviton Programmer Controller refer to the Programmer Controller instructi
2. RF to provide remote control of your lighting Using RF technology allows Leviton to provide the greatest signal integrity possible Each module in Leviton s Vizia RF component line is a Z Wave enabled device In a Z Wave network each device is designed to act as a router These routers will re transmit the RF signal from one device to another until the intended device is reached This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots The Scene Capable Plug In Appliance Module is compatible with any Z Wave enabled network regardless of the manufacturer and can also be used with other devices displaying the Z Wave logo CAUTION Remember to exercise good common sense when using the Timer features of your Remote especially when scheduling unattended devices There can be some unexpected consequences if not used with care For example an empty coffee pot can be remotely turned on If that should happen your coffee pot could be damaged from overheating If an electric heater is turned on by remote control while clothing is draped over it a fire could result DO NOT USE the remote for the control of high power heating appliances such as portable heaters This device will not control lighting that is used with electronic low voltage and high frequency power supply transformers nor high pressure discharge lamps HID lighting This includes mercury vapor
3. Load in both the switch wall box and remote wall box Preparing and connecting wires This switch can be wired using side wire terminal screws or through backwire openings Choose appropriate wire stripping specifications accordingly 5 8 1 6 cm Strip Gage cui measure bare wire here if necessary Side Wire Connection Back Wire either hole may be used Side wire terminals accept 14 Back wire openings use 14 12 AWG AWG solid wire copper only solid wire copper only e Make sure that the ends of the wires from the wall box are straight cut if necessary e Remove insulation from each wire in the wall box as shown e For Single Pole Application go to Step 4a e For 3 Way Coordinating Remote no LEDs Application go to Step 4b Single Pole Wiring Application Terminal Screw marked White WH Terminal Screw marked Black BK Terminal Screw marked Yellow Red YL RD Terminal Screw marked Red RD Terminal Label Use Terminal for 3 Way or More Applications Only For Single Pole Applications Do Not Remove This Label Switch Hot Black Black Line 120VAC 60Hz Use Terminal for 3 Way or More Applications Only For Single Pole Applications White Do Not Remove This Label Neutral White WIRING SWITCH Connect wires per WIRING DIAGRAM as follows Green or bare copper wire in wall box to Green terminal screw Line Hot wall box wire
4. Single Pole One location or 3 Way Multi location Scene Capable Electronic Switch Cat No RZS15 1L Lighted Incandescent 1800W Magnetic Low Voltage 1800VA 1440W Electronic Low Voltage 1800W Fluorescent 1800VA Supplemental 1 2 HP 120VAC 60Hz INSTALLATION INSTRUCTIONS WARNINGS AND CAUTIONS e Use only one 1 Vizia RF electronic switch in a multi location circuit with up to 9 Vizia coordinating remotes without LEDs or Vizia RF remotes for multi location e Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft 90 m e Disconnect power at circuit breaker or fuse when servicing installing or removing fixture e Use this device only with copper or copper clad wire With aluminum wire use only devices marked CO ALR or CU AL Z LEVITON Building A Connected World DI 000 RZS15 00A X3 i al Compatible with TT enabled products IZIAG WARNINGS AND CAUTIONS e To be installed and or used in accordance with appropriate electrical codes and regulations e If you are unsure about any part of these instructions consult a qualified electrician e Vizia RF electronic switches are not compatible with standard 3 way or 4 way switches They must be used with compatible Vizia or Vizia RF controllers e Recommended minimum wall box depth is 2 1 2 INTRODUCTION Leviton s Vizia RF Z Wave components are designed to communicate with each other via Radio Frequency
5. e reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving Antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio tv technician for help DI 000 RZS15 00A X3
6. edies provided herein are the exclusive remedies under this warranty whether based on contract tort or otherwise OPERATION NOTE The locator light will illuminate when the load is in the OFF position to facilitate access in the dark Push Pad Default settings Turn ON from OFF position Tap Lights turn ON Turn OFF from ON position Tap Lights turn OFF If there is a power outage when the power is restored the lights will return to the last setting before the power interruption Cleaning Clean with a damp cloth DO NOT use chemical cleaners Push Locator TROUBLESHOOTING Pad Light e Lights Flickering Lamp has a bad connection Wires not secured firmly under terminal screws of switch and or remote Light does not turn ON and Locator LED does not turn ON Circuit breaker or fuse has tripped Lamp is burned out Lamp Neutral connection is not wired e Remote does not operate lights Ensure that total wire length does not exceed 300 ft 90 m For additional information contact Leviton s Techline at 1 800 824 3005 or visit Leviton s website at www ViziaRF com U S amp Foreign Patents Pending Copyright 2006 Leviton Manufacturing Co Inc All Rights Including Trade Dress Rights Reserved FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provid
7. o Include it again without first excluding it from the network the switch will retain the first node ID it had received and ignore the second Programmer Controller Cat No RZCPG Menu Button Center Button Programmer Controller Cat No RZCPG NOTE Programmer Controller must be in close proximity to switch when including in the network Sela Excluding Switch from Z Wave Network NOTE It is very important to accurately Exclude devices from the network when moving or removing a device from a Z Wave network This ensures that all information has been removed from your Primary Programmer Controller s information table and is not counted on to be part of the mesh network A lf using a Leviton Z Wave Programmer Controller Cat No RZCPG press the Menu button and scroll down to System Setup Press the center button to select System Setup Menu Press the center button to select Network B While standing close to the switch approximately 2 5 ft press the center button to lt Exclude gt device from the network C While the Programmer Controller is in the Exclusion mode and the locator LED is ON on the Dimmer press the push pad to turn on the switch The Programmer Controller will verify Exclusion and the locator LED will turn OFF If the switch is flashing Amber while in the Exclusion mode the Programmer Controller is still trying to communicate with the switch Wait until the device stops fla
8. on sheet for Including a device A If using a Leviton Z Wave Programmer Controller Cat No RZCPG press the Menu button and scroll down to System Setup Press the center button to select System Setup Menu Press the center button to select Network B While standing close to the switch approximately 2 5 ft press the center button to lt Include gt device in the network NOTE Only one device may be included at a time DO NOT put multiple devices into the Inclusion mode at any time C While the Programmer Controller is in the Inclusion mode and the Locator LED is ON on the switch press the push pad to turn on the switch The Programmer Controller will verify inclusion and the Locator LED will turn OFF If the switch is flashing Amber while in the Inclusion mode the Programmer Controller is still trying to communicate with the switch Wait until the device stops flashing then press the push pad NOTE If the Locator LED on the switch turns solid Red while including there has been a communication error Refer to Troubleshooting section D The Primary Programmer Controller will assign a node ID number Name for this device NOTE This ID number Name will be stored in the controller to be used for future reference NOTE You may name or edit the node of this device at this time E The switch is now installed in the network NOTE If the switch has been successfully Included in the network and the user tries t
9. shing then press the push pad Factory Default If your switch is not responding or you are unable to control it after you have tried to Include Exclude it multiple times it may be necessary to reset the switch to its original factory settings To accomplish this proceed as follows e On the switch engage the air gap switch by gently pulling the bottom of the push pad until it lifts completely out of the frame and a Click is heard refer to figure Wait 5 seconds and then press the push pad back into the frame and hold push pad until the locator LED flashes Amber and turns solid Red The switch is now reset Once the switch is reset it will be necessary to Re Include it to a network before it can be used CAUTION SETTING A DEVICE TOA FACTORY DEFAULT DOES NOT EXCLUDE THAT DEVICE FROM A NETWORK THE EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE FROM THE PRIMARY CONTROLLER S INFORMATION TABLE FAILURE TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND OR MAY FAIL TO RESPOND TO SOME DEVICES Seles Switch Mounting TURN OFF POWER AT CIRCUIT BREAKER OR FUSE Gently lift bottom of push pad out Installation may now be completed by tightening mounting screws into wall box Attach wallplate Restore Power Restore power at circuit breaker or fuse Installation is complete Step 9 LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and no
10. sodium vapor and metal halide lamps e Switch ON OFF e Scene Capable e ON OFF LED e Two way communication e RF reliability e Ease of installation No new wiring e Compatible with other Z Wave enabled devices Tools needed to install your Switch Slotted Phillips Screwdriver Electrical Tape Pencil Cutters Changing the color of your Switch Your switch includes three color options The switch ships with the White frame attached To change color of frame proceed as follows Pliers Ruler eal Push in Line up tabs side at tab and press in to release side to attach INSTALLING YOUR SWITCH NOTE Use check boxes V when Steps are completed WARNING TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring Ec Identifying your wiring application most common NOTE If the wiring in your wall box does not resemble any of these configurations consult a qualified electrician o o Single Pole 3 Way 1 Line Hot 1 Line or Load see 2 Neutral important instruction 3 Ground Neutral 4 Load Ground First Traveler note color Second Traveler note color ORON IMPORTANT For 3 Way applications note that one of the screw terminals from the old switch being removed will usually be a different color Black or labeled Common Tag that wire with electrical tape and identify as the common Line or
11. t for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date Leviton s only obligation is to correct such defects by repair or replacement at its option if within such five year period the product is returned prepaid with proof of purchase date and a description of the problem to Leviton Manufacturing Co Inc Att Quality Assurance Department 59 25 Little Neck Parkway Little Neck New York 11362 2591 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merchantability and fitness for a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warranty including merchantability and fitness for a particular purpose is limited to five years Leviton is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of any equipment lost sales or profits or delay or failure to perform this warranty obligation The rem
12. to terminal screw marked BK Load wall box wire to terminal screw marked RD Line Neutral wall box wire to terminal screw marked WH Switch terminal screw marked YL RD should have Red insulation label affixed NOTE If insulating label is not affixed to terminal screw marked YL RD use electrical tape to cover Proceed to Step 5 3 Way Wiring with Coordinating Remote H no LED Application Coordinating Remote Terminal Screw marked White WH Switch Terminal M Screw marked Black BK Terminal Screw marked Yellow Red Switch Coordinating Remote no LED Ground YL RD Line 120VAC 60Hz Neutral White WIRING SWITCH Connect wires per WIRING DIAGRAM as follows NOTE The switch must be installed in a wall box that has a Line Hot connection NOTE Maximum wire length from switch to all installed remotes cannot exceed 300 ft 90 m e Green or bare copper wire in wall box to Green terminal screw e Line Hot common wall box wire identified tagged when removing old switch to terminal screw marked BK e First Traveler wall box wire to terminal screw marked RD note wire color e Remove Red insulating label from terminal screw marked YL RD e Second Traveler wall box wire to terminal screw marked YL RD note wire color This traveler from the switch must go to the terminal screw on the remote marked YL RD e Line Neutral wall box wire to terminal screw marked WH
Download Pdf Manuals
Related Search
Related Contents
Advance User Manual Graco 313435T User's Manual Mi451 Clarity XLC3.1 telephone Copyright © All rights reserved.
Failed to retrieve file