Home

LevelOne FSW-0507TX Switch User Manual

image

Contents

1. the LED Indicator section for detailed information about each of the hub s LED indicators Rear Panel 7 5VDC 1A FSW 0507TX l i 7 5VDC 1A FSW 0807TX DC Power Jack Power is supplied through an external AC power adapter Check the technical specification section for information about the AC power input voltage Since the switch does not include a power switch plugging its power adapter into a power outlet will immediately power it on Auto MDI Jacks These jacks supports automatic MDI MDIX crossover detection function gives true plug and play capability without the need of confusing crossover cables or crossover ports With the Auto MDI function you just need to plug in the network cable to the hub directly and no need to care if the end node is NIC Network Interface Card or switches and hubs LED Indicators Power Indicator PWR This indicator lights green when the hub is receiving power otherwise it is off 14 Full Duplex Collision Full Duplex Collision This LED indicator light green when a respective port is in full duplex FDX mode Otherwise it is blinking when collisions are occurring on the respective port Link Activity 100M green 10M amber This indicator light green when the port is connected to a 100Mbps Fast Ethernet station if the indicator blinking green will be transmit or received data on the 100Mbps network Otherwise if the indicator light amber when the por
2. unpacking and setup information for the Switches Unpacking Open the shipping cartons of the Switch and carefully unpacks its contents The carton should contain the following items One LevelOne 5 8 Port 10 100Mbps PalmCon Switch One external power adapter This User s Guide If any item is found missing or damaged please contact your local reseller for replacement Setup The setup of the Switch can be performed using the following steps The surface must support at least 1 5 Kg for the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the DC power jack and make sure that it is fully secured to the power adapter Make sure that there is proper heat dissipation from and adequate ventilation around the Switch Do not place heavy objects on the Switch 10 11 12 IDENTIFYING EXTERNAL COMPONENTS This section identifies all the major external components of the hub Both the front and rear panels are shown followed by a description of each panel feature The indicator panel is described in detail in the next chapter Front Panel The figure below shows the front panels of the switch Inga 100Mbps 5 rao n 09 woo a 00 o GO O FSW 05071X 5 Port 10 100MbpsPalmCon Switch FSW 0507TX 00000000 PWR Q O O O QA 100Mbps 123 4 5 6 7 8 O ten Ds H For Tay Qo Vibes Peruon Swot FSW 0807TX LED Indicator Panel Refer to
3. 0BASE TX 2 pair UTP Cat 5 EIA TIA 568 STP ae erof 5 8 x 10 100Mbps NWay Auto MDI ports 13 Physical and Environmental DC inputs 7 5 VDC 1A Power Consumption 7 5 watts max Temperature Operating 0 50 C Storage 10 70 C Humidity Operating 10 90 Storage 5 90 Dimensions 171 x 98 x 29 mm W x Hx D EMI FCC Class B CE Mark B VCCI B Performance Transmission Store and forward RAM Buffer 128KBytes per device Filtering Address Table 4K entries per device Packet 10Mbps Ethernet 14 880 pps Filterin g Forwar ding Rate 100Mbps Fast Ethernet 148 800 pps Learning 14
4. ING AND SETUP 9 UNPACKING 8 EEA 9 SETUP tias 9 IDENTIFYING EXTERNAL COMPONENTS ooococccuoaooroconcsoscnmmmesees 13 FRONT PANEL occocooconcconinocinaconconoconinononecincnnsoneconnnncornconcanecan concen 13 REAR TIN vccccccscssscsssesesssessscssssseesecsssssteseessesaressesunsseesseessens 13 LED INDICATORS ooccocconconccnnionicninononecincnnsonocnnnanconoconcanecin conca 14 CONNECTING THE SWITCH 9 PETOSWIICH iii dias 9 HUB TO SWITCH nemcine nna a 10 A LOBASE T Hub 10 B 100BASE TX Hub 10 SWITCH TO SWITCH OTHER DEVICES sscssssssssseessees 10 PORT SPEED amp DUPLEX MODE TECHNICAL SPECIFICATIONS 13 ABOUT THIS GUIDE Congratulations on your purchase of the LeveOne 5 8 Port 10 100Mbps PalmCon Switch This device integrates 100Mbps Fast Ethernet and 10Mbps Ethernet network capabilities in a highly flexible desktop package Purpose This manual discusses how to install your LevelOne 5 8 Port 10 100Mbps PalmCon Switch Terms Usage In this guide the term Switch first letter upper case refers to your LevelOne 5 8 Port 10 100Mbps PalmCon Switch and switch first letter lower case refers to other Ethernet switches Overview of this User s Guide Introduction Describes the Switch and its features Unpacking and Setup Helps you get started with the basic installation of the Switch Identifying External Components Describes the front panel rear panel a
5. LevelOne FSW 0507TX FSW 0807TX 5 8 Port 10 100M PalmCon Switch User s Guide FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures VCCI Mark Warning ER COREL PRUBRESERES Bl ARS VCCI OB CK A PRARNBECT ORES ZR TER TA ER BeES AHRITILEBHVET COBS CI A IIA RAE LOBRENOLLBDVEF P N 6012 1052004 Rev H1 01 TABLE OF CONTENTS ABOUT THIS GUIDE 1 PURPOSE Gasnor Deals 1 TERMS USAGE nE A ANA 1 OVERVIEW OF THIS USER S GUIDE 1 INTRODUCTION 7 FEATURES anannnnsnnenensennennennsnnnnnnennnennenennnnnnennennnennane 7 UNPACK
6. indicator is light amber B 100BASE TX Hub For a 100BASE TX hub the Switch LED indicators should light up as the following Full Duplex Collision LED indicator is OFF 100LINK ACT 10LINK ACT LED indicator is light green Switch to switch other devices The Switch can be connected to another switch or other devices routers bridges etc via a two pair Category 3 4 5 UTP STP cable 1 The 100LINK ACT 1OLINK ACT LED indicator light green for hookup to 100Mbps speed or light amber for hookup to 10Mbps speed 2 The Full Duplex Collision LED indicator depends upon LAN card capabilities for full duplex or half duplex 10 Port Speed amp Duplex Mode After plugging the selected cable to a specific port the system uses auto negotiation to determine the transmission mode for any new twisted pair connection If the attached device does not support auto negotiation or has auto negotiation disabled an auto sensing process is initiated to select the speed and set the duplex mode to half duplex 11 TECHNICAL SPECIFICATIONS General Standards IEEE 802 3 10BASE T Ethernet IEEE 802 3u 100BASE TX Fast Ethernet ANSI IEEE 802 3 NWay Auto negotiation IEEE 802 3x Full duplex Flow Control CSAC Data Ethernet 10Mbps half duplex 20Mbps full duplex Transfer Rate Network 10BASE T 2 pair UTP Cat 3 4 5 EIA TIA 568 STP Cables Fast Ethernet 100Mbps half duplex 200Mbps full duplex 10
7. nd LED indicators of the Switch Connecting the Switch Tells how you can connect the Switch to your Ethernet network Technical Specifications Lists the technical general physical and environmental and performance specifications of the Switch INTRODUCTION This chapter describes the features of the Switch and some background information about Ethernet Fast Features The Switch was designed for easy installation and high performance in an environment where traffic on the network and the number of user increase continuously The Switch with its small compact size was specifically designed for small to middle workgroups This Switch can be installed where space is limited moreover they provide immediate access to a rapidly growing network through a wide range of user reliable functions The Switch is ideal for deployment with multiple high speed servers for shared bandwidth 10Mbps or 100Mbps workgroups With the highest bandwidth 200Mbps 100Mbps full duplex mode any port can provide workstations with a congestion free data pipe for simultaneous access to the server The Switch is expandable by cascading two or more switches together As all ports support 200Mbps the Switch can be cascaded from any port and to any number of switches The Switch is a perfect choice for site planning to upgrade to Fast Ethernet in the future Ethernet workgroups can connect to the Switch now and change adapters and hubs anytime later without
8. needing to change the Switches or reconfigure the network The Switch combine dynamic memory allocation with store and forward switching to ensure that the buffer is effectively allocated for each port while controlling the data flow between 7 the transmit and receive nodes to guarantee against all possible packet loss The Switch is a managed 10 100 Fast Ethernet Switch that offers solutions in accelerating small Ethernet workgroup bandwidth Other key features are Auto MDI function supports automatic MDI MDIX crossover detection function gives true plug and play capability without the need of confusing crossover cables or crossover ports Store and forward switching scheme capability As the result of complete frame checking and error frame filtering this scheme prevents error packages from transmitting among segments NWay Auto negotiation for any port This allows for auto sensing of speed 10 100Mbps thereby providing you with automatic and flexible solutions in your network connections Flow control for any port This minimizes dropped packets by sending out collision signals when the port s receiving buffer is full Note that flow control is only available in half duplex mode Data filtering forwarding rate is wire speed for 10Mbps and 100Mbps speed 4K MAC address entry table per device with self learning for the Switch 128KBytes RAM buffer per device for the Switch UNPACKING AND SETUP This chapter provides
9. t is connected to a 10Mbps Ethernet station if the indicator blinking amber will be transmit or received data on the 10Mbps network 15 CONNECTING THE SWITCH This chapter describes how to connect the Switch to your Fast Ethernet network In each of the following figures the LevelOne 5 8 Port 10 100Mbps PalmCon Switch is shown PC to Switch A PC can be connected to the Switch via a two pair Category 3 4 5 UTP STP cables The PC equipped with a RJ 45 10 100Mbps phone jack should be connected to any of the 5 8 ports The LED indicators for PC connection dependent on the LAN card capabilities If LED indicators are not light after making a proper connection check the PC LAN card the cable the Switch conditions and connections The following are LED indicator possibilities for a PC to Switch connection 1 The 1OOLINK ACT 1OLINK ACT LED indicator light green for hookup to 100Mbps speed or light amber for hookup to 10Mbps speed 2 The Full Duplex Collision LED indicator depends upon LAN card capabilities for full duplex or half duplex Hub to Switch A hub 10 or 100BASE TX can be connected to the Switch via a two pair Category 3 4 5 UTP STP cable The connection is accomplished from the hub to any of the Switch RJ 45 ports A LOBASE T Hub For a 10BASET hub the Switch LED indicators should light up as the following Full Duplex Collision indicator is OFF 100LINK ACT 10LINK ACT LED

Download Pdf Manuals

image

Related Search

Related Contents

6316008 horloge contrôlée par radio mode d`emploi  ham2007 – three-digit entry alarm + magnetic contact  ESPECIFICAÇÕES TÉCNICAS - Portal Gênesis / Senac-Am  HP ENVY Recline 27-k190ez TouchSmart  4000112810-02 francais.indd    据付工事説明書 - トーヨーキッチン  My Weigh Durascale 50 & 100 Models User Manual  Amtrol SPT-56 User's Manual  Nodor RDOS 46  

Copyright © All rights reserved.