1. Detection accuracy 1 cent Sound accuracy 1 5 cents Tuning guide range Auto chromatic 50 cents 3 cents b 3 cents 3 cents b 3 cents 50 cents Manual 500 cents 3 cents 3 cents 3 cents 3 cents 500 cents zb b if Connectors INPUT 1 4 mono OUTPUT 1 4 mono DCIN 9V Power supply AAA batteries x 2 3V or AC adapter O Battery life Approximately 100 hours Alkaline batteries Meter mode A4 continuous input Dimensions WxDxH 74 x 120 x 36mm 2 91 x 4 71 x 1 42 Weight 193g 6 8 oz including the battery Included items AAA batteries x 2 for checking operation Options AC adapter C 0 sold separately Appearance and specifications are subject to change without notice Using the stand By opening the stand located on the back you can position the GT 120 at a convenient angle amp The VUstyle meter may drift from the 0 position center when the OT 120 is tilted If this occurs perform the procedure described in Adjusting the zero point of the VU style meter while the unit is tilted so that the VU style meter points to 0
2. OOO O Thank you for purchasing the Korg GT 120 guitar bass chromatic tuner Be fore you use the GT 120 GUITAR BASS CHROMATIC TUNER GT 120 Owner s Manual please read this owner s manual carefully and use the GT 120 as directed Keep this manual for fu ture reference Precautions Location Using the unit in the following locations can result in a malfunction In direct sunlight Locations of extreme temperature or humidity Excessively dusty or dirty locations Locations of excessive vibration Power supply Please connect the designated AC adaptor to an AC outlet of the correct voltage Do not connect it to an AC outlet of voltage other than that for which your unit is in tended Interference with other electrical devices This product contains a microcomputer Radios and televisions placed nearby may experience reception interference Operate this unit at a suitable distance from ra dios and televisions Handling To avoid breakage do not apply excessive force to the switches or controls Care If the exterior becomes dirty wipe it with a clean dry cloth Do not use liquid clean ers such as benzene or thinner or cleaning compounds or flammable polishes Keep this manual After reading this manual please keep it for later reference Keeping foreign matter out of your equipment Never set any container with liquid in it near this equipment If liquid gets into the equipment it could cause a break
3. 1E 6E DADGAD 6D 5A 4D 3G 2A 1D 6D BASS LB 4E 3A 2D 1G HC LB LB Low B HC High C Specify the note name When using AUTO Play a single note on your instrument and the name of the nearest note will appear in the LCD display Tune your instrument so that the cor rect note name is shown in the LCD display When using MANUAL Press the NOTE switch until the note you wish to tune C B appears in the LCD display e Each time you press the AUTO MANUAL switch the setting will switch between AUTO and MANUAL 6 Play a single note on your instrument and tune it so that the needle of the meter is at the 0 position center and both indicators of the tuning guide are lit amp While tuning do not allow extraneous sounds to enter the mic AUTO Meter mode Auto MANUAL Meter mode manual SOUND Sound mode manual Note name C C D Eb E F FH G G A Bb B String number not displayed for CHROMATIC u Flat tuning AUTO bbbb MANUAL yy SOUND Ip Octave 0 displayed only for CHROMATIC Reference pitch calibration Tuning is correct when the needle indicates the 0 position center and both tuning guide indicators are lit E Sound mode 1 Make the settings described in steps 1 4 of Meter mode 2 Press the SOUND switch to enter Sound mode manual 3 Press the NOTE switch until the note to which you wish to tune appears in the LCD display 4 Listen to
4. the pitch sounded by the GT 120 and tune your instrument accordingly To return to Meter mode press the AUTO MANUAL switch Flat tuning When the TUNING TYPE dial is set to GUITAR or BASS you can use Meter mode or Sound mode to tune to a pitch that is lowered by 1 4 semitones b bbb for the specified note 1 As described in Meter mode or Sound mode make the note you wish to flatten by 1 4 semitones appear in the LCD display Set the TUNING TYPE dial to either GUITAR or BASS Flat tuning can only be used for these selections 2 Press the FLAT switch to select the number of semitones that you wish to lower the selected note The LCD screen will indicate b bbb 1 4 semitones 3 Tune your instrument Replacing the batteries and the memory function As the batteries begin to run down accurate tuning will become more difficult Check the battery indicator in the LCD display and replace the batteries as soon as necessary The batteries are also used to preserve the memory when the power is turned off allowing the reference pitch meter mode manual and the note you selected for Sound mode to be remembered Memory function amp When the batteries are removed or if they run down completely the various settings preserved by the memory function will be reset If an AC adapter is connected to the GT 120 and plugged into an AC outlet the settings will not be reset Even if you are using the GT 120 wi
5. down fire or electrical shock Be careful not to let metal objects get into the equipment If something does slip into the equipment unplug the AC adaptor from the wall outlet Then contact your nearest Korg dealer or the store where the equipment was purchased CE mark for European Harmonized Standards CE mark which is attached to our company s products of AC mains operated apparatus until December 31 1996 means it conforms to EMC Directive 89 336 EEC and CE mark Directive 93 68 EEC And CE mark which is attached after January 1 1997 means it conforms to EMC Directive 89 336 EEC CE mark Directive 93 68 EEC and Low Voltage Directive 73 23 EEC Also CE mark which is attached to our company s products of Battery operated apparatus means it conforms to EMC Directive 89 336 EEC and CE mark Di rective 93 68 EEC THE FCC REGULATION WARNING for U S A This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guar antee that interference will not occur in a particular installation If this equip ment does cause
6. er you may want to turn the GT 120 power switch STANDBY to avoid noise amp If a plug is inserted into the INPUT jack or OUTPUT jack the built in mic cannot be used Both jacks are mono They cannot be used with stereo plugs If you wish to tune your instrument using the built in mic do not con nect a plug to the INPUT jack or OUTPUT jack In steps 5 and 6 place your instrument as close as possible to the built in mic Turn the power switch to the ON or position At the lt position the power will be on and in addition the display will be illuminated When the power is turned on the previously selected reference pitch default setting A 440 Hz will be selected and the GT 120 will be in Meter mode Auto If you wish to change the reference pitch calibration press the CALIB switch Each time you press it the reference pitch will rise 1 Hz If you con tinue holding it the pitch will rise continuously The available range is 438 Hz 445 Hz Rotate the TUNING TYPE dial to select the appropriate instrument or set to CHROMATIC Move the appropriate instrument name to the gt mark Each setting allows the following tuning Default values for MANUAL CHROMATIC C D Eb E F Ft G Gt A Bb B A sound output A4 GUITAR 6E 5A 4D 3G 2B 1E 6E OPEN D 6D 5A 4D 3 2A 1D 6D OPEN E 6E 5B 4E 3G 2B 1E 6E OPENG 6D 5G 4D 3G 2B 1D 6D OPEN A 6E 5A 4E 3A 2C
7. harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Unauthorized changes or modification to this system can void the user s au thority to operate this equipment 2005 KORG INC LCD display 1B wii Meter dienne KORG TA Tuning guide AUTO NOTE switch l MERET ofe w ou AUTO MANUAL switch QMQOOoOwMG CALIB switch TY SOUND switch FLAT switch Power switch STANDBY ON 4 TUNING TYPE dial DC IN jack connect to AC adapter OUTPUT jack INPUT jack Tuning procedure The GT 120 has two tuning modes Meter mode auto manual in which you tune while watching a meter and Sound mode manual in which you tune to an audible reference tone E Meter mode 1 If you are using an instrument with a pickup such as an electric gui tar or a mic connect the instrument or mic to the INPUT jack of the GT 120 If you connect the GT 120 s OUTPUT jack to your amp etc the sound will be output thru the tuner During your performance howev
8. th an AC adapter you should leave the batteries installed 1 Press lightly and slide in the direction of the arrow to open RG the lid of the battery case Adjustment screw 3 Close the lid of the battery case 2 Insert two AAA Oo batteries Be careful to observe the correct polarity Adjusting the zero point of the meter needle If the GT 120 is jarred while being transported etc or due to normal ag ing after extended use the VU style meter may drift away from the 0 position center Please re adjust the VU style meter to the 0 position so that tuning will be accurate 1 While holding down the AUTO MANUAL switch turn the power switch ON and check whether the meter needle indicates the 0 posi tion N If it does not indicate the 0 position refer to the diagram in the above section Replacing the batteries and the memory function open the battery cover and use a small Philips screwdriver such as a jeweler s screwdriver to rotate the adjustment control so that the needle indicates 0 Q After making the adjustment or if the meter needle indicated 0 in step 1 press any one of the switches to return to normal operation and close the battery cover Scale 12 note equal temperament A0 C8 C2 C7 5 octaves Meter auto manual Sound manual Range Reference tone Tuning modes Flat tuning 1 4 semitones semitone steps Calibration range A4 438 445 Hz 1 Hz steps

Download Pdf Manuals

image

Related Search

Related Contents

iCatchLive Pet WS 取扱説明書  User Manual of U452 USB relay board  HERMA Removable labels A4 Ø 20 mm round white Movables/removable paper matt 2400 pcs.  CLICK PLC/PLCs/Programmable Logic Controllers/PLC controller  Garmin GHC 20 Control Unit Flat Mount Template  Signal Hound BB60A  RT-ZD40 User Manual  Blackbird Docking Adapter PMD-DOK2    