Home
KitchenAid Convection Oven Convection Oven User Manual
Contents
1. knockout opening Sp knockout for power opening for supply 40 amp cable power supply cord 8 m Depending on your electrical supply make the four wire or three wire connection to the range following the Power supply cord method or Direct wire method instructions for copper wire or aluminum wire depending on the connection needed Power supply cord method NOTE The bag containing three aluminum terminal lugs is not used when connecting the range using a power supply cord AWARNING Electrical Shock Hazard Disconnect power before servicing Use a new 40 amp power supply cord Plug into a grounded outlet Failure to follow these instructions can result in death fire or electrical shock WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded Do not modify the power supply cord plug If it will not fit the outlet have a proper outlet installed by a qualified electrician This range is manufactured with the neutral terminal connected to the cabinet Use a three wire U L listed 40 amp power supply cord pigtail or if local codes Do Not permit ground through the neutral use a four wire power supply cord rated at 250 volts 40 amps and investigated for use with ranges See Four wire electrical connecti
2. 30 76 2 cm opening width junction box 8 20 3 cm to wall or other 22 55 9 cm from either combustible cabinet 7 17 8 cm max from material floor 7 A1 l a 7 8 2 2 cm ez min required N between cutout and cabinet door or hinge NOTE 24 61 cm min when bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm min clearance between the top of the cooking platform and the bottom of an unprotected wood or metal cabinet Slide in ranges countertop preparation The cooktop sides of the slide in range fit over the cutout edge of your countertop If you have a square finish flat countertop and the opening width is 30 76 2 cm no countertop preparation is required 30 76 2 cm opening width Formed front edged countertops Must have molded edge shaved flat 1 2 1 3 cm from each front corner of opening 30 7 8 78 4 cm Tile countertops may need trim cut back 1 2 1 3 cm from each front corner and or rounded edge flattened If countertop opening width is greater than 30 76 2 cm adjust the 1 2 1 3 cm dimension Countertop must be level Place level on countertop at front corners of countertop opening first side to side then
3. KitchenAid HOME APPLIANCES Installation Instructions 30 Electric Range Quick Reference with self cleaning Table of Contents thermal convection Pages Before you start oven Product dimensions 3 Cabinet dimensions requirements Electrical requirements Freestanding 5 Installation steps Check operation Range If range does not operate If you need assistance service ll llale le gt 5 e N Moving the range If you need assistance Check your Use and Care Guide for a toll free number to call or call the dealer from whom you purchased this appliance The dealer is listed in the Yellow Pages of your phone directory under Appliances Household Major Service and Repair Call when you M Have questions about range installation or operation M Need to obtain the name and number of an authorized service company Slide in Range When you call you will need M The range model number M The range serial number Both numbers are listed on the model serial rating plate located on the oven frame behind the storage drawer panel AWARNING Part No 9757988 Tip Over Hazard IMPORTANT Read and save these instructions A child or adult can tip the range and be killed IMPORTANT Installer Leave Installation Instructions with the homeowner Homeowner Keep Installation Ins
4. 1 1 Pull drawer open to first stop position Lift front of drawer to clear white wheels in drawer guides Remove 1 5 m Replace the storage drawer or drawer and set it aside on a protected lower panel surface 1 6 m Reconnect power anti tip bracket 1 2 Making sure the anti tip bracket is installed e Look for the anti tip bracket securely attached to floor e Slide range back so rear range foot is under anti tip bracket 1 3 If installing the range ina mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Mobile home installation instructions Page 2 Check operation OFF 17 s 7 m Push in and turn each surface unit control knob to HI position Check the operation of the cooktop elements and indicator z 2 lights ae gQ s MED NIGHT LIGHT DELAY START SET PROBETEMP 18 88 mme O S88 F mee 8 88 ose ipaq 18 88 DEHYDRATE CONVECTION FOOD AT LLIN ENTER STANDARD COOKTIME HR MIN MIN SEC CLOSE CONTROL LOCK EASYCONVECT COOKTEMP CLEANTIME DOOR LOCKED START TIME SET START CANCEL CONVECTION STOP CONVECT fs OVEN OFF BAKE J BROIL ROAST TIME MEAL Q ucht ET START J CANCEL Control panels may vary EASY CONVECT CONVERSION MEATS 1 8 Check the operation of the oven element Press the BAKE pad 350 F will appear in the temperature display Press the START
5. 7 30 76 2 cm hea 27 3 4 25 3 4 width 70 5 cm When installed in a 24 65 4 cm depth with Pa 61 cm base cabinet with 25 depth with handle 63 5 cm countertop front of handle cabinet oven door protrudes 1 7 8 4 8 cm beyond 24 61 cm base Cabinet dimensions requirements Freestanding Range For minimum clearance to the top of the V cooktop see NOTE 13 33 cm max upper cabinet depth 30 76 2 cm min cabinet opening width 18 45 7 cm upper cabinet to countertop 30 76 2 cm opening width 4 10 2 cm min clearance from both sides FNS of range to side wall or other junction box 8 20 3 cm to 22 55 9 cm from Combustible either cabinet material 7 17 8 cm max from floor ae 1 Pea 7 8 2 2 cm Lc min required AS between cutout and cabinet door or hinge Cabinet opening dimensions shown are for 25 63 5 cm countertop depth 24 61 cm base cabinet depth 36 91 4 cm countertop height 18 45 7 cm upper cabinet to countertop 4 10 2 cm min clearance ya from both sides of range to side Slide in Range 13 33 cm max upper cabinet depth 30 76 2 cm min cabinet opening width For minimum clearance to the top of the cooktop see NOTE 22 3 4 57 8 cm opening depth lt j 1 2 1 3 cm radius both corners
6. be tightened to 20 in lbs of torque for proper electrical connection Complete electrical connection according to your type electrical supply Four wire electrical connection or Three wire electrical connection co Four wire electrical connection ground screw slotted set screw line 2 neutral center _ wire Figure 2 Use this method for new installations mobile homes recreational vehicles and whenever four wire installation is required 10 Remove the ground link screw from the range frame Save the ground link screw and cup washer Bend up the ground link so that it does not contact the range See Figures 1 and 2 Connect the bare ground wire to the range using the ground link screw and cup washer The ground wire must be attached first and must not contact any other terminal See Figure 2 12 Loosen do not remove the 3 slotted set screws Insert the neutral white wire into the hole at the bottom of the center position lug attached to center terminal screw black terminal block See Figure 2 Connect the other two wires line 1 and 2 to the outer aluminum lugs Securely tighten the set screws For 8 gauge copper wire tighten to 25 in lbs of torque and for _ 6 gauge aluminum wire tighten to 35 in Ibs of torque to make a proper electrical connection See Figure 2 13 Tighten the locking ring of the conduit connector 14 Replace the terminal bl
7. for cleaning or maintenance 1 Unplug range or disconnect power 2 Slide range forward to complete cleaning or maintenance anti tip bracket 3 Make sure the anti tip bracket is installed e Look for the anti tip bracket securely attached to floor e Slide range back so rear range foot is under anti tip bracket 4 Check that range is level 5 Plug in range or reconnect power Notes Part No 9757988 2003 KitchenAid Registered Trademark of KitchenAid Prepared by KitchenAid Benton Harbor Michigan 49022 Printed in U S A
8. four wire 120 208 volt if specified on the model serial rating plate is required on a separate 40 amp circuit fused on both sides of the line M A time delay fuse or circuit breaker is recommended M The range can be connected directly to the fused disconnect or circuit breaker box through flexible armored conduit See Direct wire method Copper wire or Direct wire method Aluminum wire sections Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary A U L listed conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with the rating of the range 40 amps The wiring diagram is located on the back of the range or on the inside of the storage drawer in a clear plastic bag If connecting to a four wire system This range is manufactured with the ground connected to the cabinet The ground must be revised so the green grounding wire of the four wire power supply cord is connected to the cabinet See Four wire electrical connection section Page 6 Formed or tiled countertop trimmed 1 2 1 3 cm back 1 2 FE 13 cm 22 5 8 57 5 cm Cooktop sides of range fit over edges of countertop opening When a four wire receptacle of NEMA Type 14 50R is used see Figure 1 a matching U L listed four wire 250 volt 40 amp range powe
9. installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located on the oven frame behind the storage drawer panel Check location where range will be installed The range should be located for convenient use in kitchen When installing a range under existing cabinets and the installation does not meet the minimum cabinet clearances install a range hood above the cooktop to avoid burn hazards All openings in the wall or floor where ranges is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical outlet is required See Electrical requirements Page 4 Mobile home installation The installation of this range must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or with local codes When this range is installed in a mobile home it must be secured to the floor during transit Any method of securing the range is adequate as long as it conforms to the standards listed above Four wire power supply cord or cable must be used in a mobile home installation The appliance wiring will
10. pad Lo will appear in the display then 170 F when oven reaches 170 F The bottom element should glow red and the indicator light should be on The upper element should become hot but not glow red As the oven temperature rises the temperature in the display will increase in 5 F increments until the oven reaches the set temperature Press CANCEL OFF pad 1 9 m Check the operation of the broil element Close the oven door Press the BROIL pad 500 F will appear in the temperature display Press the START pad Look through the oven window The top element should glow red Press the CANCEL OFF pad To get the most efficient use from your new electric range read your KitchenAid Use and Care Guide Keep Installation Instructions and Guide close to the electric range for easy reference If range does not operate Check that the circuit breaker is not tripped or the house fuse blown Check that the power supply cord is plugged into the outlet See Use and Care Guide for troubleshooting list If you need assistance If you have questions about operating cleaning or maintaining your range Refer to Use and Care Guide The KitchenAid Consumer Assistance Center will answer any questions about operating or maintaining your range not covered in the Installation Instructions The KitchenAid Consumer Assistance Center is open 24 hours a day 7 days a week Just dial
11. 1 800 422 1230 the call is free within the continental United States When you call you will need the range model number and serial number Both numbers can be found on the model serial rating plate located on the oven frame behind the door 10 If you need service In the event that your KitchenAid appliance should need service call the dealer from whom you purchased the appliance or a KitchenAid authorized service company A KitchenAid authorized service company is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service amp Repair You can also obtain the service company s name and number by dialing free within the continental United States the KitchenAid Customer Interaction Center telephone number 1 800 422 1230 A special operator will tell you the name of your nearest KitchenAid authorized service company Maintain the quality built into your KitchenAid appliance call a KitchenAid authorized service company Moving the range AWARNING Tip Over Hazard A child or adult can tip the range and be killed Connect aniti tip bracket to rear range foot Reconnect the anii tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults When moving range slide range onto cardboard or hardboard to prevent damaging the floor covering If removing the range is necessary
12. front to back If countertop is not level range will not be level Oven must be level for satisfactory baking conditions Electrical requirements If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path and wire gauge are in accordance with local codes This range must be connected to a grounded metal permanent wiring system Check with a qualified electrician if you are not sure range is properly grounded Do Not ground to a gas pipe Do Not have a fuse in the neutral or ground circuit Recommended ground method It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA 70 latest edition and all local codes and ordinances Power supply cord is not supplied but is available through your local electrical supply house Range must be connected to the proper electrical voltage and frequency as specified on the model serial rating plate The model serial rating plate is located on the oven frame behind the storage drawer panel Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 A four wire or three wire single phase 120 240 volt 60 Hz AC only electrical supply or three wire or
13. need to be revised See Four wire electrical connection Page 4 The floor anti tip bracket MUST be installed To install the anti tip bracket 5 shipped with the range see Page 5 and the anti tip bracket template Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Tools needed level e flat blade screwdriver e 3 8 drive ratchet e 3 8 and 5 16 nut driver e hand or electric drill e channel lock pliers e safety glasses gloves measuring tape or ruler e wood floors 1 8 drill bit e concrete ceramic floors 3 16 carbide tipped masonry drill bit Hammer may be needed for anchors Parts supplied Not shown 2 plastic anchors E 2 screws floor mounted 10 x 1 1 2 anti tip bracket Brackets must be securely mounted to sub floor Thickness of flooring may require longer screws to anchor bracket to sub floor Longer screws are available from your local hardware store Product dimensions Freestanding Range 30 8 1 4 76 2 cm 21 cm cooktop width ee F 1 1 2 turns NS 1 2 5 om l spacer z 44 3 3 112 7 cm overall height 36 91 4 cm cooktop height with feet loosened 36 91 4 cm 22 5 8 cooktop 57 5 cm height with feet loosened 1 1 2 turns q 2 5 cm Slide in Range 30 76 2 cm 1 1 2 cooktop 3 8 cm Ta
14. ock cover Three wire electrical connection slotted set screw line 1 Figure 3 Use this method only if local codes permit connecting ground conductor to neutral supply wire 10 Loosen do not remove the 3 slotted set screws Insert the neutral white wire into the hole at the bottom of the center position lug attached to center terminal screw of terminal block See Figure 3 Connect the other two wires lines 1 and 2 to the outer aluminum lugs Securely tighten the set screws For 8 gauge copper wire tighten to 25 in lbs of torque and for 6 gauge aluminum wire tighten to 35 in lbs of torque to make a proper electrical connection See Figure 3 Tighten the locking ring of the conduit connector 12 Replace the terminal block cover 1 _ Operating position 9 m Move range close to cabinet LLM SS opening LMU 1 0 Remove cardboard or 1 4 hardboard from under range Carefully m Place rack in oven Place level move range into final position on rack first side to side then front to back If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket Use 3 8 drive ratchet and channel lock pliers to adjust leveling legs up or down until range is level Push range back into position Check that rear leveling leg is engaged in anti tip bracket NOTE Oven must be level for satisfactory baking conditions
15. om the carton Stack one cardboard corner on top of another Repeat with other two corners Place them lengthwise on the floor behind the range to support the range when it is laid on its back Firmly grasp the range and gently lay it on its back on the cardboard corners 3 m Pull cardboard shipping base firmly to remove 4 Use an adjustable wrench to loosen the leveling legs four complete turns 5 m Place cardboard or hardboard in front of range Stand range back up onto cardboard or hardboard AWARNING Tip Over Hazard A child or adult can tip the range and be killed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type floor covering 6 m Use the anti tip bracket template to install the anti tip bracket Anti tip bracket must be anchored securely to the sub floor Depending on the thickness of your flooring longer screws may be necessary to anchor the bracket to the sub floor Longer screws are available from your local hardware store Check that range is on cardboard shipping base to protect floor covering Electrical connection terminal block cover 7 Remove the terminal block cover located on the back of range
16. on opening for conduit connector remove knockout for 40 amp power cord and U L listed strain relief 1 Disconnect power 2 Remove the knockout for the 40 amp power supply cord 3 Assemble a U L listed strain relief in the opening 4 Insert the power supply cord through the strain relief allowing enough slack to 6 easily attach the wiring to the terminal block 5 Use only ring type terminals to connect the power supply 6 Complete electrical connection according to your type electrical supply Four wire electrical connection or Three wire electrical connection Four wire electrical connection Figure neutral wire center wire center terminal block screw PN om sy ground link w Cc ground link screw SUG line 1 line 2 green ground ULL listed strain relief and 40 amp range power supply cord Figure 2 Use this method for new installations mobile homes recreational vehicles and whenever four wire installation is required 7 Remove the ground link screw from the range frame Save the ground link screw Bend up the ground link so that it does not contact the range See Figure 1 Connect the green ground wire from power supply cord to the range using the ground link screw The ground wire must be attached first and must not contact any other terminal See Figure 2 Use 3 8 nut driver and remove the out
17. r supply cord pigtail must be used This cord contains four copper conductors with ring terminals at the appliance end terminating in a NEMA Type 14 50P plug on the supply end The fourth grounding conductor must be identified by a green or green yellow cover and the neutral conductor by a white cover Cord should be Type SRD or SRDT with a U L listed strain relief and be at least four feet long The minimum conductor sizes for the copper four wire power cord are 40 amp circuit 2 No 8 conductors 1 No 10 white neutral 1 No 8 green grounding If connecting to a three wire system Local codes may permit the use of a U L listed 250 volt 40 amp range power supply cord pigtail This cord contains three No 10 copper wires and matches a three wire receptacle of NEMA Type 10 50R shown in Figure 2 Connectors on the appliance end must be provided at the point the power supply cord enters the appliance UG Y xi y fw 4 wire wall 3 wire wall receptacle 14 50R receptacle 10 50R Figure 1 Figure 2 Now start AWARNING Excessive Weight Hazard Use two or more people to move and install range Failure to do so can result in back or other injury 1 m Put on safety glasses and gloves Remove shipping materials tape and protective film from range Keep cardboard bottom and shipping base under range Remove oven racks and parts package from inside oven 2 m Take four cardboard corners fr
18. side nuts on the terminal block screws Do not loosen the factory tightened nuts behind the outside nuts go so 10 Connect the neutral wire center wire to the center terminal screw on the terminal block See Figure 2 11 Connect the other two wires lines 1 and 2 to the outer screws on the terminal block See Figure 2 12 Securely tighten nuts with 3 8 nut driver for proper electrical connection 13 Tighten the strain relief screws 14 Replace the terminal block cover 15 Plug power supply cord into grounded electrical outlet Three wire electrical connection center terminal block screw NI Sy neutral IE SA eK 72 ww L listed strain relief and 40 amp range power supply cord Figure 3 Use this method only if local codes permit connecting cabinet ground conductor to neutral wire of power supply cord 7 Use 3 8 nut driver and remove the outside nuts on the terminal block screws Do not loosen the factory tightened nuts behind the outside nuts 8 Connect the neutral wire center wire to the center terminal screw on the terminal block See Figure 3 9 Connect the other two wires lines 1 and 2 to outer terminal screws on the terminal block See Figure 3 10 Securely tighten nuts with 3 8 nut driver for proper electrical connection 11 Tighten the strain relief screws 12 Replace the terminal block cover 13 Plug power supply cord into grounded elec
19. trical outlet Direct wire method Copper or Aluminum wire NOTE The bag containing three aluminum terminal lugs must be used when making a direct wire connection AWARNING 4 Electrical Shock Hazard Disconnect power before servicing Use 8 gauge copper or 6 gauge aluminum wire Elecirically ground range Failure to follow these instructions can result in death fire or electrical shock This range may be connected directly to the fuse disconnect or circuit breaker box or with a U L listed 40 amp range power supply cable Depending on your electrical supply make the required three wire or four wire connection 1 Disconnect power 2 Remove the knockout as needed for conduit connection 3 Assemble a U L listed conduit connector in opening U L listed conduit connector CS N SZ 7 gt a Ea Strip the insulation back 1 inch from the end of each wire Allow enough slack in the wire to easily attach the wiring terminal block Use 3 8 nut driver and remove the outside nuts on the terminal block screws Do not loosen the factory tightened nuts behind the outside nuts o D terminal aluminum Screw lug set screw must face out 7 IMPORTANT the aluminum lugs must be assembled to the terminal posts with the set screws facing out as shown 8 Attach three aluminum lugs to terminal posts Use a 3 8 nut driver and tighten the nuts securely Nuts must
20. tructions for future reference Save Installation Instructions for local electrical inspector s use Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is moved Failure to follow these instructions can result in death or serious burns to children and adults www kitchenaid com Before you start Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean ADANGER You can be killed or seriously injured if you don t immediately follow instructions AWARNING You can be killed or seriously injured if you don t follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed IMPORTANT Observe all governing codes and ordinances Failure to meet codes and ordinances could lead to fire or electrical shock Proper installation is your responsibility A qualified technician must install this range Make sure you have everything necessary for correct installation It is the