Home
Kidde KN-OOSM-IB Carbon Monoxide Alarm User Manual
Contents
1. P gina 17 Funcionamiento del indicador LED P gina 17 Caracter stica de protecci n contra la manipulaci n indebida us pan Pati Qu hacer si suena la alarma Alarma contra humo Alarma contra mon xido de carbono Retiro de la alarma reemplazo de bater as Mantenimiento general de la alarma P ginas 17 18 P ginas 18 19 P ginas 20 P ginas 21 22 P ginas 26 27 Informaci n de seguridad sobre el mon xido de carbono Informaci n general sobre el mon xidode carbono Fuentes posibles Consejos de seguridad sobre el mon xidode carbono S ntomas de intoxicaci n por mon xidode carbono Informaci n de seguridad contra incendios Plan de Prevenci n de Normas de seguridad de la industria Asociaci n Nacional de Protecci n contraincendios cias Jefe de bomberos del estado de California Comisi n para la Seguridad de los Productosde Consumo Comisi n Reguladora Nuclear Informaci n de garant a limitada y servicio Registro del producto P gina 24 P gina 24 P gina 25 P ginas 25 26 P gina 26 P gina 27 P ginas 27 28 P gina 28 P gina 28 P gina 28 P ginas 29 30 P ginas 30 31 Introducci
2. Alarma fuerte de 85 decibeles e Sensores independientes de humo y mon xido de carbono permanentes La alarma contra humo tiene prioridad cuando se encuentren presentes humo y mon xido de carbono Recibe alimentaci n del cable de 120 V CA 60 Hz 25mA m x del conector El modelo KN COSM IB tambi n est equipado con una bater a de emergencia de 9 V El modelo KN COSM IB tambi n se encuentra equipado con una leng eta de extracci n para conectar f cilmente la bater a S lo saque la leng eta y se conectar la bater a Se interconecta con otras alarmas contra humo y mon xido de carbono de marca Kidde Nighthawk consulte la p gina 16 para obtener detalles Sistema de advertencia con mensaje de voz alarma que lo alerta de las siguientes condiciones en la manera que se describe a continuaci n eliminando de esa forma cualquier confusi n por la cual la alarma est sonando FUEGO El patr n de alarma voz son tres pitidos de alarma largos seguidos del mensaje de advertencia verbal FUEGO Este patr n se repite hasta que se elimine el humo El LED rojo destellar mientras se encuentre en el modo de alarma voz MONOXIDO DE CARBONO El patr n de alarma voz son cuatro pitidos de alarma cortos seguidos del mensaje de advertencia verbal ADVERTENCIA MONOXIDO DE CAR BONO Esto contin a hasta que se restablece la unidad o se elimina el mon xido de carbono Aunque s lo reciba ali mentaci
3. Kidde User s Guide for Models KN COSM I and KN COSM IB Combination Smoke and Carbon Monoxide Alarm e 120V AC 9V Battery Backup model KN COSM IB 2 LED Display Peak Level Memory Hush Voice Message System Kidde SMOKE AND CARBON MONOXIDE ALARM OPERATE SIGNALING LISTED For questions concerning your Smoke and Carbon Monoxide Alarm please call our Consumer Hotline at 1 800 880 6788 For your convenience write down the following information If you call our consumer hotline these are the first questions you will be asked Alarm Model Number located on back of the alarm Date of Manufacture located on back of the alarm Date of Purchase Where Purchased READ AND SAVE THIS USER S GUIDE Manual P N 810 1512 Rev H Table of Contents Introduction e i eoi L AAE iu SK cuu Page 1 Product View Pages 2 3 Features iio e wae Pages 4 7 Installation Instructions Step 1 Installation Instructions A Recommended Installation Locations Pages 8 10 B Where Not to Install Page 10 Step 2 Wiring Instructions Page 11 12 Step 3 Mounting Instructions Page 13 14 Step 4 Testing the Alarm Page 14 Operating Instructions Interconnect Feature 2 0 06606 riesaa Page 15 HUSH Control Feature 15
4. Prueba los dispositivos electr nicos de las unidades y verifica el funcionamiento correcto de las unidades Restablece la unidad durante la alarma contra mon xido de carbono Activa la funci n de silenciador Activa la funci n memoria de nivel m ximo Funci n de control de silenciador que silencia la unidad durante situaciones de alarmas molestas Consulte la p gina 16 La funci n memoria de nivel m ximo que alerta al usuario cuando la unidad ha detectado concentraciones de mon xido de carbono de 100 PPM o mayores Consulte la p gina 17 Caracter stica de memoria de alarma que proporciona se al visu al cuando una alarma ha detectado una condici n peligrosa Los LED verde y rojo indican el funcionamiento normal y el estado de la alarma consulte la p gina 17 para obtener detalles La caracter stica de protecci n contra la manipulaci n indebi da ayuda a evitar que ni os y otras personas retiren la alar ma Consulte la p gina 18 Caracter sticas de la alarma contra humo El modelo KN COSM IB tambi n se encuentra equipado con un se alizador del indicador de bater a que proh be la insta laci n cuando la bater a no se encuentra adentro Despu s de siete 7 a os del encendido inicial esta unidad emitir un chirrido cada 30 segundos Esta es una carac ter stica de fin de la vida til que indicar que es tiempo de reemplazar la alarma Alarma contra humo La alarma contra hum
5. mara y no necesita ajuste ni mantenimiento Esta alar ma contra humo cumple o supera todas las normas guberna mentales Se fabrica y distribuye bajo la licencia de la Comisi n Reguladora Nuclear de los Estados Unidos Garant a limitada GARANTIA LIMITADA DE CINCO A OS KIDDE garantiza que la alarma adjunta excluida la bateria no presenta defectos de material mano de obra ni de dise o para su uso y servicio en condiciones normales durante un per odo de cinco a os a partir de la fecha de compra La obligaci n de KIDDE seg n esta garant a se limita a reparar o reemplazar la alarma o cualquier pieza que consideremos que presente defectos de material mano de obra o disefio sin costo alguno contra envio de la alarma con un comprobante de la fecha de compra franqueo y franqueo de devoluci n prepagados a Warranty Service Department KIDDE 1016 Corporate Park Drive Mebane NC 27302 Esta garant a no ser v lida para una alarma contra humo si sta ha sufri do da os modificaciones se le ha dado un mal uso o ha sido alterada despu s de la fecha de compra o si no puede funcionar debido a un mantenimiento inadecuado o al uso inapropiado de CA o CC La duraci n de todas las garant as impl citas que surjan de esta venta entre otras las garant as impl citas de descripci n comerciabilidad e idoneidad para un prop sito en particular se limita al per odo de garant a arriba estipulado En ning n caso el fabricante ser res
6. n Gracias por comprar la alarma combinada contra humo y mon xido de carbono Kidde modelo 1 o KN COSM IB Esta alarma es apropiada para funcionar como estaci n nica y o m ltiples estaciones 24 dispositivos Esta alarma tiene una garant a limitada de cinco a os Dedique algunos minutos para leer completamente esta gu a del usuario y gu rdela para con sultarla en el futuro Ense e a sus hijos c mo deben responder a las alarmas y a nunca jugar con la unidad Su alarma contra humo mon xido de carbono Kidde fue dise ada para detectar humo y mon xido de carbono de cualquier fuente de com busti n en un ambiente residencial No est dise ada para su uso en un veh culo de recreaci n o bote Si tiene alguna pregun ta acerca del funcionamiento o de la instalaci n de su alarma llame gratis a la l nea directa para el consumidor al 1 800 880 6788 La gu a de la p gina 28 le ayudar a determi nar la ubicaci n correcta de los productos de seguridad que har n de su hogar un lugar m s seguro Vista del producto PARTE FRONTAL BOT N PROBAR LED ROJ O RE STAB LE C E R Diodo fotoemisor SILENCIADOR SMOKE AND CARBON MONOXIDE ALARM RESONADOR LED VERDE DE LA ALARMA Diodo fotoemisor Vista del producto PARTE POSTERIOR CARACTER STICA DE PROTECCI N CONTRA MANIPULACI N INDEBIDA ESPIGAS DEL COMPARTIMIENTO CONECTOR DE CA DE BATERIAS S lo modelo KN COSM IB Caracter sticas
7. va la memoria de nivel m ximo Despu s de la instalaci n PRUEBE LOS DISPOSITIVOS ELECTR NICOS DE LA UNIDAD presionando y soltando el bot n probar restablecer Sonar n una serie de pitidos seguidos del mensaje iFUEGO iFUEGO luego otras dos series de pitidos y el mensaje ADVERTENCIA MON XIDO DE CARBONO seguido de 4 pitidos cortos adicionales Es necesario hacer pruebas semanalmente Si en alg n momento no funciona como se describe verifique que la energ a est conectada correctamente y que no sea necesario reemplazar las bater as Limpie el polvo y otras acumulaciones de la unidad Si a n no funciona adecuadamente llame a la l nea directa para el consumidor al 1 800 880 6788 Caracter stica de interconexi n Su alarma combinada contra humo mon xido de carbono se puede interconectar con otros productos de estaciones m lti ples Kidde Nighthawk y Kidde Fyrnetics Cuando se interconectan alarmas contra humo y de calor compatibles a su alarma contra humo mon xido de carbono s lo responder n a un evento relacionado con el humo Cuando se mezclan modelos compatibles que poseen bater as de emergencia con modelos sin estos elementos advertimos que los modelos sin las bater as de emergencia no se accionar n durante un corte de CA Esta unidad s lo est aprobada para interconectarse con otros productos Kidde Nighthawk NO se encuentran aprobados para interconectarse con productos de det
8. 16 Reset Featuren asi o Ae Mies 16 Peak Level Memory Page 17 LED Indicator Page 17 Tamper Resist Feature Page 17 18 What to do if the Alarm Sounds Smoke Pages 18 19 Carbon Monoxide Alarm Pages 20 Alarm Removal Battery Replacement Pages 21 22 General Alarm Maintenance Pages 26 27 Carbon Monoxide Safety Information General CO Information Page 24 Possible SourceS Page 24 CO Safety Tips L u lan teat aes Page 25 Symptoms of CO Poisoning Page 25 26 Fire Safety Information Escape ts p ae Page 26 Fire Page 27 Industry Safety Standards National Fire Protection Association Page 27 28 California State Fire Marshall Page 28 Consumer Product Safety Commission Page 28 A soq kas Rese wes Page 28 Limited Warranty and Service Information Pages 29 30 Product Registration Page 30 Introduction Thank you for purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model KN COSM I or KN COSM IB This alarm is suitable as a Single Station and or Multiple Station 24 devices alarm This alarm has a five year limited warranty Please take a few minutes to thoroughly read this us
9. 9 m de lo siguiente La puerta que d a una cocina o a un ba o que tenga una ba era o ducha los conductos de suministro de aire a presi n para calefacci n o refrigeraci n los ventiladores de cielo raso o en otras reas de corrientes de aire Evite las reas con exceso de polvo suciedad o grasa El polvo la grasa y los qu micos dom sticos pueden contaminar los sensores de la alarma impi diendo su funcionamiento normal Coloque la alarma en lugares donde las cortinas u otros objetos no bloqueen el sensor El humo y el mon xido de carbono deben llegar a los sensores para que la unidad pueda detectar adecuadamente estas condiciones No la instale en v rtices de cielos rasos abovedados con forma de A o en techos de gabletes Mant ngala lejos de reas mojadas o h medas Inst lela a una distancia m nima de un 1 pie de luces fluores centes porque el ruido electr nico puede causar alarmas molestas No la exponga a la luz solar directa y mant ngala fuera de reas infestadas de insectos Las temperaturas extremas afectan la sensibilidad de la alarma contra humo mon xido de carbono No la instale en reas en que la temperatura sea inferior a 40 grados Fahrenheit 4 4 Celsius o superior a 100 grados Fahrenheit 37 8 Celsius No la instale en 10 Instrucciones de instalaci n reas en las cuales la humedad relativa HR sea superior al 85 Col quela lejos de puertas y ventanas que se abran hacia el exterio
10. It is manufactured and distributed under license from the U S Nuclear Regulatory Commission 28 Warranty and Service Information Limited Warranty FIVE YEAR LIMITED WARRANTY KIDDE warrants that the enclosed alarm but not the battery will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase The obligation of KIDDE under this warranty is limited to repairing or replacing the alarm or any part which we find to be defective in material workmanship or design free of charge upon sending the alarm with proof of date of purchase postage and return postage prepaid to Warranty Service Department KIDDE 1016 Corporate Park Dr M ebane NC 27302 This warranty shall not apply to the alarm if it has been dam aged modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC power Any implied warranties arising out of this sale including but not limited to the implied warranties of description merchantability and fitness for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liab
11. KN COSM IB only powered by only battery backup The LED will flash every 5 seconds Alarm Memory Condition The LED will flash every second signifying that the alarm sensed a smoke or CO hazard It will continue to flash every second until the test reset button is pressed thus resetting the alarm HUSH MODE Condition The LED will flash every 2 seconds while the alarm is in HUSH mode Tamper Resist Feature To make your smoke CO alarm tamper resistant a tamper resist feature has been provided Activate the tamper resist feature by breaking off the four posts in the square holes in the trim ring see figure 5A When the posts are broken off the tamper resist tab on the base is allowed to engage the mounting brack et Rotate the alarm onto the mounting bracket until you hear the tamper resist tab snap into place locking the alarm on the mounting bracket Using the tamper resist feature will help deter children and others from removing the alarm from brack et NOTE To remove the alarm when the tamper resist tab is engaged press down on the tamper resist tab and rotate the alarm off of the bracket see figure 5B 17 Operating Instructions FIGURE 5 FIGURE 5B NEVER IGNORE THE SOUND OF THE ALARM Determining what type of alarm has sounded is easy with your Nighthawk Combination Smoke CO Alarm The voice message warning system will inform you of the type of situation occur ring Refer to the Features
12. National Electrical Code ANSI NFPA 70 NFPA 72 and or any other codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the same raceway or cable as the AC power wiring In addition the resistance of the interconnect wiring shall be a maximum of 10 ohms The appropriate power source is 120 Volt AC Single Phase supplied from a non switchable circuit which is not protected by a ground fault interrupter Smoke alarms are not to be used with detector guards unless the combination alarm and detector guard have been evalu ated and found suitable for that purpose WARNING The alarm cannot be operated from power derived from a square wave modified square wave or modi fied sine wave inverter These types of inverters are some times used to supply power to the structure in off grid instal lations such as solar or wind derived power sources These power sources produce high peak voltages that will damage the alarm WIRING INSTRUCTIONS FOR AC QUICK CONNECT HARNESS CAUTION TURN OFF THE MAIN POWER TO THE CIRCUIT BEFORE WIRING THE ALARM For alarms that are used as single station DO NOT CONNECT THE RED WIRE TO ANYTHING Leave the red wire insulating cap in place to make certain that the red wire cannot contact any metal parts or the electrical box When alarms are interconnected all interconnected units must be powered from a single circuit 11 Installation Instructi
13. STICA EN LA P GINA 18 PARA OBTENER INSTRUCCIONES SOBRE EL RETIRO DE LA ALARMA Retire la alarma del soporte de montaje al girar la alarma en la direcci n de la flecha OFF que se encuentra en la cubierta Para desconectar el cableado de CA apriete los brazos de cierre de los lados del conector r pido sacando al mismo tiempo el conector de la parte inferior de la alarma consulte la p gina 14 Figura 4 Reemplazo de bater as S lo para el modelo KN COSM IB Si se detecta cualquier forma de falla de la bater a destellar el LED rojo y la unidad emitir un chirrido seguido del mensaje de advertencia BATER A BAJA Este ciclo se producir una vez cada minuto y continuar por lo menos durante siete d as 22 Reemplazo de bater as s lo el modelo KN COSM 1B Si el LED rojo destella junto con emitir un chirrido cada 30 segundos y no va seguido del mensaje de voz BATER A BAJA como se describi anteriormente su unidad no funciona bien Llame gratis a nuestra l nea directa para el con sumidor al 1 800 880 6788 para obtener instrucciones sobre la devoluci n de la unidad PRECAUCI N LA ALARMA CONTRA HUMO MON XIDO DE CARBONO ESTA SELLADA Y LA CUBIERTA NO ES REMOVIBLE Para reemplazar la bater a primero debe sacar la alarma del soporte de montaje de acuerdo con las instrucciones del RETIRO DE LA ALARMA que se encuentran al principio de esta secci n Despu s que retire la alarma
14. alarma contra mon xido de carbono indica la presencia de mon xido de carbono CO que puede OCASIONARLE LA MUERTE Si suena una se al de alarma 1 Presione el bot n probar restablecer 2 Llame a los servicios de emergencias departamento de bomberos u 911 3 Ret rese de inmediato a un lugar donde corra aire puro ya sea afuera o cerca de una ventana o puerta abierta Cuente las personas una por una para comprobar que todas ellas se encuentren presentes No vuelva a entrar al lugar ni se aleje de la puerta o ventana abierta hasta que hayan llegado los servicios de emergencia se haya aireado el lugar y su alarma est en su condici n normal 4 Despu s de seguir los pasos 1 al 3 si su alarma se reactiva dentro de un per odo de 24 horas repita los pasos 1 al 3 y llame un t cnico calificado para que investigue las fuentes de ipa de carbono pravero niente de equipos y aparatos quemadores de combustible y verifique el correcto funcionamiento de este equipo Si se identifican problemas durante esta inspecci n haga reparar el equipo inmediatamente Observe todo equipo de combusti n que no haya sido inspeccionado por el t cnico y consulte las instrucciones del fabricante o comun quese directamente con el fabricante para obtener mayor informaci n acerca de la seguridad con respecto al mon xido de carbono y sobre este equipo Aseg rese de que los veh culos motorizados no est n o no hayan estado funcionando en
15. de dos salidas de cada habitaci n puerta y ventana e identifique un lugar de encuentro fuera de la casa en que cada uno de los integrantes se re na una vez que hayan salido de la vivienda Cuando hayan llegado dos personas al lugar de encuentro una debe llamar al 911 mientras que la segunda persona debe quedarse para contar a los miembros de la familia iEstablezca una regla de que una vez afuera no se debe volver a entrar por ning n motivo Prevenci n de incendios Nunca fume en la cama ni deje coci nando alimentos en la cocina sin supervisi n Ense e a sus hijos a nunca jugar con f sforos o encende dores Entrene a cada integrante de la I casa para que reconozca el patr n de l e a alarma la advertencia de mensaje de 1 LA VOZ y para que salga de la casa usando A su plan de escape cuando escuche la 1 1 z FIRE EXTINGUISHERS Sepa c mo detenerse dejarse caer y i rodar por el suelo si el fuego envuelve swoxe acarms su ropa y c mo gatear bajo el humo CARBON MONOXIDE Instale y mantenga extintores de Cra incendios en cada piso de la casa y en la cocina s tano y garaje Sepa c mo usar un extintor de incen dios antes de que se produzca una emergencia El segundo piso y las habitaciones con ventanas ocupadas en pisos m s altos deben tener una escalera de emergencia O smoke co ALARM 28 Informaci n de garant a
16. interconectado es de 1 000 pies En la Figura 3 se muestra un cableado de interconexi n Una conexi n inadecuada originar da os a la alarma incapacidad de funcionamiento de sta o riesgo de recibir una descarga el ctrica Aseg rese de que algunas alarmas est n cableadas en una linea de alimentaci n continua no conmutada NOTA Use el cable est ndar aprobado por UL calibre 18 o mayor seg n lo requieran los c digos locales disponible en todas las tien das de suministros el ctricos y la mayor a de las ferreter as 12 Instrucciones de instalaci n FUSIBLE O INTERRUPTOR AUTOM TICO Primera 7 alarma del m dulo de rel s de Kidde 7 adicional lt Accesorio opcional FIGURA 3 DIAGRAMA DEL CABLEADO DE INTERCONEXI N CABLES EN CABLEADO CONECTADO DEALARMA Negro Polo vivo de l nea de CA Blanco Polo neutro de linea roja de CA Rojo L neas de interconexi n cables rojos de otras unidades en un esquema de estaciones m ltiples Paso 3 Instrucciones de montaje PRECAUCI N LA ALARMA CONTRA HUMO MON XIDO DE CARBONO ESTA SELLADA Y LA CUBIERTA NO ES REMOVIBLE 1 Para ayudar a identificar la fecha de reemplazo de la unidad se ha colocado una etiqueta al costado de la alarma Escriba la fecha de reemplazo en la etiqueta Replace by 7 a os a partir de la activaci n inicial con un marcador permanente Para obtener
17. n de la bater a despu s de cuatro minutos el patr n de alarma voz sonar cada un minuto El diodo fotoemisor LED rojo se encender cuando se encuentre en el modo larma voz BATER A BAJA s lo para el modelo KNCO SM IB Cuando las bater as est n bajas y se deban reemplazar el LED rojo se encender y la unidad emitir un chirrido una vez seguido del mensaje de advertencia BATER A BAJA Este ciclo se producir una vez cada minuto y continuar por lo menos durante siete d as Caracter sticas El sistema de mensaje de voz alerta al usuario en las sigu ientes condiciones El sistema anuncia SE ACTIVO EL MODO DE SILENCI ADOR cuando la unidad se ponga por primera vez en el modo de silenciador El sistema anuncia SE CANCEL EL MODO DE SILENCI ADOR cuando la unidad reanuda su funcionamiento normal despu s que se haya cancelado el modo de silen ciador El sistema anuncia SE DETECT PREVIAM ENTE MONOXIDO DE CARBONO detectado concentraciones de mon xido de carbono de 100 PPM o mayores El sistema anuncia PRESIONE EL BOT N PROBAR cuan do se enciende la unidad lo que le recuerda al usuario que debe activar el bot n probar Un chirrido cada 30 segundos es una se al de que la alar ma no est funcionando bien Si esto sucede llame a la linea directa para el consumidor al 1 800 880 6788 El bot n probar restablecer realiza las siguientes funciones
18. ni os peque os de la casa Salga de la casa inmediatamente usando una de las rutas de escape planificadas consulte la p gina 28 Cada segundo cuenta no se detenga para vestirse o tomar objetos de valor Antes de abrir las puertas interiores aseg rese de ver si hay humo filtr ndose por los bordes y haga contacto con la parte posterior de la mano Si la puerta est caliente use la segun da salida de emergencia Si cree que es segura abra la puerta muy lentamente y est preparado para cerrarla de inmediato si entra una bocanada de humo y calor Si al escapar debe pasar a trav s del humo gatee por debajo del humo donde el aire est m s limpio Dir jase al lugar de encuentro predeterminado Cuando dos personas hayan llegado al punto de encuentro una debe lla mar al 911 desde la casa de un vecino y la otra debe uedarse para contar a los habitantes de la casa 19 Qu hacer si suena la alarma No vuelva a ingresar por ning n motivo hasta que os bomberos den la autorizaci n para hacerlo Hay situaciones en la que puede que una alarma contra humo no sea efectiva para proteger contra un incendio seg n lo que se establece en la Norma 72 de la NFPA Por ejemplo a fumar en la cama b dejar a los ni os sin supervisi n c limpiar con liquidos inflamables como gasolina 20 Qu hacer si suena la alarma Cuando suena la alarma contra mon xido de carbono ADVERTENCIA La activaci n de esta
19. nivel de mon xido de carbono de 100 PPM o superior desde el ltimo restablecimiento la funci n memoria de nivel m ximo lo regis trar Para acceder la memoria de nivel m ximo presione el bot n probar restablecer Si se registr una lectura de 100 ppm o mayor la unidad anunciar Se detect mon xido de carbono previamente Si ha estado ausente de su hogar esta funci n le permite verificar si hubo una lectura de mon xido de carbono de 100 PPM o superior durante su ausencia Al presionar el bot n probar restablecer se reestablece la memoria Tambi n se restablece cuando se desconecta la energ a Funcionamiento de indicador LED LED rojo El LED rojo destellar junto con el pitido de la alarma Por lo tanto el LED rojo destellar durante una alarma de humo una alarma de mon xido de carbono o un chirrido de modo de bater a baja y un chirrido de modo de error en la unidad LED verde El LED verde destellar como se describe a continuaci n de acuerdo con las siguientes condiciones CONDICI N DE ESPERA recibe alimentaci n de CA y de la bater a de emergencia El LED estar encendido con stantemente pero parpadear cada 30 segundos cuando se tome una lectura de mon xido de carbono CONDICI N DE ESPERA recibe alimentaci n de CA y de la bater a de emergencia El LED estar encendido con stantemente pero parpadear cada 30 segundos cuando se tome una lectura de mon xido de carbono 17 Instruc
20. puede abrir la puerta del compar timiento de bater as y reemplazar la bater a Las instrucciones de instalaci n de las bater as se encuentran en el interior de la puerta del compartimiento de bater as Al instalar la bater a presione hacia abajo el enganche de reten ci n indicador de bater a en el compartimiento e instale la bater a consulte la Figura 6 Enganche de la bater a FIGURA 6 REEMPLAZO DE BATER AS PRECAUCI N SI NO SE MANTIENE PRESIONADO EL ENGANCHE DE RETENCI N INDICADOR DE BATER A EN EL COMPARTIMIENTO CORRESPONDIENTE LA PUERTA DEL COMPARTIMIENTO NO SE CERRAR EL CONECTOR R PIDO DE CA NO SE CONECTAR A LA ALARMA Y A SU VEZ STA NO SE CONECTAR AL SOPORTE DE MONTAJE Despu s de instalar o cambiar la bater a vuelva a instalar la alarma Pru bela usando el bot n probar restablecer y verifique que est encendido el LED verde 23 Mantenimiento general Reemplace las bater as por una de las siguientes marcas aprobadas Duracell MN1604 MX1604 Energizer 522 PANA SONIC 6AM 6 6AM 6 6AM 6PI 6AM 6X y 6LR61 GA Ultralife U9VL Estas bater as se pueden comprar en el mercado local ADVERTENCIA Use s lo las bater as que se especifican El uso de bater as diferentes puede tener un efecto adverso en la alarma contra humo mon xido de carbono Una buena medida de seguridad es reemplazar la bater a por lo menos una vez al a o o al mismo tiempo que cambie sus relojes a
21. ter mointercambiadores de caldera Verifique que el color de la llama del piloto y de los aparatos de calefacci n sea azul Una llama amarilla o anaranjada es una se al de que no se est con sumiendo adecuadamente el combustible Ense e a todos los miembros de la familia el sonido de la alarma y la forma de responder ante sta 26 Informaci n de seguridad contra incendios S ntomas de intoxicaci n por mon xido de car bono Los s ntomas iniciales de intoxicaci n por mon xido de carbono son similares a los de la gripe sin fiebre y pueden incluir mareos intensos dolores de cabeza n useas v mitos y desorientaci n Cada uno de nosotros es susceptible a sufrir intoxicaci n por mon xido de carbono pero los expertos est n de acuerdo en que los beb s nonatos las mujeres embarazadas los ancianos y las personas con problemas card acos y respiratorios son espe cialmente vulnerables Si experimenta s ntomas de intoxicaci n por mon xido de carbono busque inmediatamente atenci n m dica La intoxicaci n por mon xido de carbono se puede determinar mediante un examen de carboxihemoglobina Los siguientes s ntomas est n relacionados con la INTOXICACION POR MONOXIDO DE CARBONO y se deben analizar con TODOS los miembros de la familia 1 Exposici n leve Dolor de cabeza leve n useas v mi tos fatiga descritos normalmente como s ntomas simi lares a la gripe 2 Exposici n media dolor de cabeza intenso
22. un garaje adjunto o adyacente a la residencia Nunca vuelva a activar la fuente de un problema de mon xido de carbono hasta que se haya reparado iNUNCA IGNORE LA ALARMA N MERO DE TEL FONO 21 Retiro de la alarma reemplazo de bater as El sensor de mon xido de carbono cumple con los requerimien tos de tiempo de respuesta ante una alarma de UL norma 2034 Los tiempos de alarma est ndar son los siguientes Con 70 PPM la unidad debe dar la alarma dentro de 60 a 240 minutos Con 150 PPM la unidad debe dar la alarma dentro de 10 a 50 minutos Con 400 PPM la unidad debe dar la alarma dentro de 4 a 15 minutos Esta alarma contra mon xido de carbono est dise ada para detectar gas de mon xido de carbono desde CUALQUIER fuente de combusti n NO est dise ada para detectar ning n otro tipo de gas Los bomberos la mayor a de las compa as de servicios p blicos y los contratistas de HVAC realizar n inspecciones de mon xido de carbono algunos de ellos pueden cobrar por este servicio Es recomendable que pregunte por las tarifas correspondientes antes de que se preste el servicio Kidde Safety no pagara ni reembolsara al propietario o usuario de este producto por ninguna llamada de reparaci n o despacho relacionada con la activaci n de la alarma Retiro de la alarma SI EST ACTIVADA LA CARACTER STICA DE PROTECCI N CONTRA LA MANIPULACI N INDEBIDA CONSULTE LA DESCRIPCI N DE ESTA CARACTER
23. y servicio Normas de seguridad de la industria NFPA Asociaci n Nacional de Protecci n contra Incendios Para su informaci n la Norma 72 de la Asociaci n Nacional de Protecci n contra Incendios se ala lo siguiente Detecci n de humo Donde lo requiera la ley las normas o los c digos aplicables a la ocupaci n espec fica de una vivienda se deber n instalar las alarmas contra humo con estaci n m ltiple y simple aprobada de la siguiente manera 1 En todos los dor mitorios excepto No se requerir la instalaci n de alarmas con tra humo en los dormitorios de una y dos viviendas unifamil iares 2 Afuera de cada dormitorio y pr ximo a los mismos 3 En cada nivel de la vivienda unifamiliar incluyendo el s tano excepto Se permite el uso de alarmas contra humo accionadas con pilas y aprobadas en viviendas unifamiliares existentes Detecci n de humo Son necesarias m s alarmas contra humo Es posible que el n mero requerido de alarmas contra humo no proporcione una protecci n de advertencia confiable y a tiempo en aquellas reas que est n separadas por una puerta de las reas protegidas Por este motivo se recomienda que el propietario de la casa considere usar alarmas contra humo adi cionales en aquellas reas a fin de contar con una mejor pro tecci n Las reas adicionales incluyen el s tano los dormito rios el comedor el rea destinada a la calefacci n el rea desti nada a los servicios gen
24. 0 ppm or higher System announces PUSH TEST BUTTON when the unit is powered up reminding user to activate the Test Button One chirp every 30 seconds is an indication that the alarm is malfunctioning If this occurs call the Consumer Hotline at 1 800 880 6788 Test Reset button performs the following functions Tests the units electronics and verifies proper unit operation Resets the unit during CO alarm Activates HUSH Feature Activates Peak Level Memory Feature HUSH Control Feature that silences the unit during nuisance alarm situations see page 15 Peak Level Memory Feature which alerts user when the unit has detected CO concentrations of 100 ppm or greater see page 16 Alarm Memory Feature that gives visual indication when an alarm has sensed a hazardous condition Green and red LED lights that indicate normal operation and alarm status see page 17 for details Tamper Resist Feature that deters children and others from removing the alarm see page 17 Model KN COSM IB is equipped with a battery reminder flag that prohibits installation when battery is not present 5 Features and General Information Seven 7 years after initial power up this unit will chirp every 30 seconds This is an operational end of life feature which will indicate that it is time to replace the alarm Smoke Alarm The smoke alarm monitors the air for products of combustion that are produced w
25. Attn Warranty Returns 1016 Corporate Park Dr M ebane NC 27302 USA Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Consumer Hotline at 1 800 880 6788 Damage from neglect abuse or failure to adhere to any of the enclosed instructions will result in termination of the warranty and the unit will not be replaced or repaired Product Registration This manual and the products described herein are copyrighted with all rights reserved Under these copyright laws no part of this manual may be copied for use without the written consent of Kidde If you require further information please contact out Consumer Hotline at 1 800 880 6788 or write us at Kidde Products 1016 Corporate Park Dr Mebane NC 27302 Our internet address is www kidde com 30 QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at ww w kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 Custom Assembled in China with U S and Foreign Components Kidde Guia del usuario por Modelos KN COSM I y KN COSM IB ALARMA COMBINADA CONTRA HUMO Y MONOXIDO Con sistema de mensaje de voz silenciador y nivel de memoria maximo Bater a de emergencia de 120VCA y9V g Kidde SMOKE AND CARBON MONOXIDE ALARM SIGNALING LISTED Para consultas relac
26. E INSTALAR EN UN CIELO RASO O EN UNA PARED iNO FUE DISE ADA PARA SU USO COMO UN DISPOSITIVO PARA COLOCAR SOBRE UNA REPISA INST LELA COMO SE INDICA A Ubicaciones de instalaci n recomendadas Kidde Safety recomienda la instalaci n de una Alarma contra humo mon xido de carbono en las siguientes ubicaciones Para obtener una m xima protecci n recomendamos instalar la alar ma en cada piso de una casa de varios pisos que incluya cada dormitorio pasillos ticos y s tanos terminados Coloque las alarmas en ambos extremos del dormitorio pasillo o habitaci n grande si el pasillo o la habitaci n tiene m s de 30 pies 9 1 m de largo Si tiene s lo una alarma aseg rese de que est ubica da en el pasillo fuera del rea principal de los dormitorios o en la habitaci n principal Verifique que la alarma se pueda o r en todas las habitaciones Coloque una alarma en cada habitaci n en que una persona duerma con la puerta cerrada Es posible que la puerta cerrada impida que una alarma que no est ubi cada en esa habitaci n despierte a la persona que duerme El humo el calor y los productos de combusti n suben al cielo raso y se propagan horizontalmente La instalaci n de la alarma en el cielo raso en el centro de la Minimo habitaci n deja la ak alarma m s cerca de todos los puntos de la habitaci n En 4 pulg 10 cm construcciones de MEJOR NUNCA de viviendas comunes es AQU AQUI preferi
27. F THE BATTERY REMINDER FINGER IS NOT HELD DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY THE BATTERY DOOR WILL NOT CLOSE THE AC QUICK CONNECTOR WILL NOT ATTACH TO THE ALARM AND THE ALARM WILL NOT ATTACH TO THE MOUNTING BRACKET After installing or changing the battery reinstall your alarm Test your alarm by using the test reset button and check that the green LED is on Replace batteries with one of the following approved brands Duracell MN1604 M X1604 Energizer 522 PANASONIC 6AM6 6AM 6 6AM 6PI 6AM 6X and 6LR61 GA Ultralife U9VL J These batteries can be purchased at your local retailer 22 General Maintenance WARNING Use only the batteries specified Use of different batteries may have a detrimental effect on the Smoke CO alarm A good safety measure is to replace the battery at least once a year or at the same time yo change your clocks for day light saving time Alarm Replacement Seven years after initial power up this unit will chirp every 30 seconds to indicate that it is time to replace the alarm A label has been provided on the side of the alarm that has Replace by printed on it Write the replace by date on the label The date written on the label should be after seven 7 years of cumulative power REPLACE IMMEDIATELY IT WILL NOT DETECT CO IN THIS CONDITION To keep your Smoke CO Alarm in good working order please follow these simple steps Verify the unit s alarm and LED lights o
28. ION BEFORE USING THE ALARM HUSH FEATURE IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS Reset Feature If the the Smoke CO Alarm is sounding a CO alarm pressing the test reset button will silence the alarm If the CO condition that caused the alert continues the alarm will reactivate Reactivation times depend on the amount of CO present see page 21 Peak Level Memory If the CO sensor has detected a CO level of 100 PPM or higher since last reset it will be recorded by the Peak Level Memory function To access the Peak Level Memory press the test reset button If a reading of 100 PPM or higher has been recorded the unit will announce Carbon Monoxide Previously detected If you ve been away from home this feature allows you to check if there was a CO reading of 100 or higher during your absence Pushing the test reset button resets the memory It s also reset when the power is removed 16 Operating Instructions LED Indicator Operation Red LED Red LED will flash in conjunction with the alarm beep Therefore the red LED will flash during a smoke alarm a CO alarm a low battery mode chirp and a unit error mode chirp Green LED The green LED will flash as described below under the following conditions Standby Condition powered by AC and battery backup The LED will be constantly on but will flicker every 30 seconds when a CO reading is taken Standby Condition for model
29. NGUISHERS Know how to do Stop Drop smoke ararms and Roll if clothes catch on CARBON MONOXIDE fire and how to craw low ALARMS under smoke Install and smokevco ALARM maintain fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emer gency Second level and higher occupied rooms with windows should have an escape ladder Industry Safety Standards NFPA National Fire Protection Association For your information the National Fire Protection Association s Standard 72 reads as follows Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms Exception Smoke alarms shall not be required in sleeping rooms in existing one and two family dwelling units 2 Outside of each separate sleeping area in immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit including basements Exception In existing one and two family dwelling units approved smoke alarms powered by batteries are permitted Smoke Detection Are More Smoke Alarms Desirable The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door 27 Industry Safety Standards from the areas protected by the required smoke alarms For this reason it
30. Note any combustion equipment not inspected by the technician and consult the manufacturer s instructions or contact the manufacturer s directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence Never restart the source of a CO problem until it has been fixed NEVER IGNORE THE ALARM 20 Alarm Removal and Battery Replacement The CO sensor meets the alarm response time requirements of UL standard 2034 Standard alarm times are as follows At 70 PPM the unit must alarm within 60 240 minutes At 150 PPM the unit must alarm within 10 50 minutes At 400 PPM the unit must alarm within 4 15 minutes This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion It is NOT designed to detect any other gas Fire Departments most utility companies and HVAC contractors will perform CO inspections some may charge for this service It s advisable to inquire about any applicable fees prior to having the service performed Kidde Safety will not pay for or reim burse the owner or user of this product for any repair or dis patch calls related to the alarm sounding Alarm Removal IF TAMPER RESIST FEATURE HAS BEEN ACTIVATED REFER TO TAM PER RESIST FEATURE DESCRIPTION ON PAGE 19 FOR REMOVAL INSTRUCTIONS Remove the alarm from the mounting bracket by rotating th
31. ONEXI N R PIDA DE CA 6 Instale la alarma en el soporte de montaje y gire la alarma en la direcci n de la flecha ON de la cubierta hasta que la alarma se ajuste en su lugar esta funci n de ajuste permite una alineaci n est tica Nota La alarma se montar en el soporte en 4 posiciones cada 90 grados 7 Active la CA Se debe encender el indicador verde de CA cuando la alarma est funcionando con CA 8 Se incluyen dos etiquetas con la alarma Contienen informa ci n importante sobre qu hacer en caso de una alarma Agregue el n mero de tel fono de su proveedor de servicios de emergencia bomberos o el 911 en el espacio correspon diente Coloque una etiqueta junto a la alarma despu s de montarla y la otra cerca de una fuente de aire fresco tal como una puerta o una ventana 9 S lo para el modelo KN COSM IB Saque completamente la leng eta de extracci n de la bater a leng eta amarilla que sobresale de la unidad Esto conectar autom ticamente la bater a x 14 Instrucciones de puesta en funcionamiento Paso 4 Prueba de la alarma PRECAUCI N Debido a la intensidad ac stica 85 decibeles de la alarma permanezca siempre a un brazo de distancia de la unidad en el momento de realizar la prueba El bot n probar restablecer tiene cuatro prop sitos Prueba los dispositivos electr nicos de la unidad restablece la alarma con tra mon xido de carbono activa la funci n de silenciador y acti
32. a en una condici n de insensibilidad temporal Su alar ma contra humo mon xido de carbono se restablecer autom ticamente despu s de aproximadamente 10 minutos Cuando la unidad regrese al funcionamiento normal despu s de haber estado en el modo de silenciador anunciar verbalmente SE CANCELO EL MODO DE SILENCIADOR y sonar la alarma si todav a hay humo presente La funci n de silenciador se uede usar repetidamente hasta que haya desaparecido la condi ci n que causa la alarma M entras la unidad est en el modo de silenciador tambi n puede presionar el bot n probar restablecer de la alarma para terminar el per odo de silenciador NOTA LA PRESENCIA DE HUMO MUY DENSO ANULAR LA FUNCI N DE CONTROL DE SILENCIADOR Y LA ALARMA SONARA EN FORMA CONTINUA 16 Instrucciones de puesta en funcionamiento PRECAUCI N ANTES DE USAR LA FUNCI N DE SILENCI ADOR DE LA ALARMA IDENTIFIQUE LA FUENTE DEL HUMO Y ASEGURESE DE QUE LAS CONDICIONES EXIS TENTES SEAN SEGURAS Funci n restablecer Si la alarma contra humo mon xido de carbono emite una alar ma de mon xido de carbono presione el bot n probar restable cer para silenciar la alarma Si contin a la condici n de mon xi do de carbono que caus la alerta se reactivar la alarma Los tiempos de reactivaci n dependen de la cantidad de mon xido de carbono presente Consulte la p gina 22 Memoria de nivel m ximo Si el sensor de mon xido de carbono detecta un
33. alta frecuencia que da ar n la alarma INSTRUCCIONES PARA UN CABLEADO DE CONEXI N RAPIDA DE CA PRECAUCI N DESACTIVE EL SUMINISTRO DE ENERG A PRINCIPAL QUE VA AL CIRCUITO ANTES DE CONECTAR LOS CABLES DE LA ALARMA 11 Instrucciones de instalaci n En alarmas que se usan como una estaci n nica NO CONECTE EL CABLE ROJO A NADA Deje en su lugar el casquillo aislante para asegurar que el cable rojo no haga contacto con ninguna pieza de metal ni con la caja el ctrica e Cuando las alarmas est n interconectadas todas las unidades interconectadas deben activarse desde un circuito nico En una disposici n de estaciones m ltiples se pueden inter conectar un m ximo de 24 dispositivos Kidde Safety El sis tema interconectado no debe exceder el l mite de interconex i n de la NFPA de 12 alarmas contra humo y o 18 alarmas en total contra humo mon xido de carbono combinada contra humo mon xido de carbono de calor etc Esta alarma com binada contra humo mon xido de carbono se debe consider ar como una alarma contra humo al determinar el n mero de unidades de una linea de interconexi n Con 18 alarmas interconectadas a n es posible interconectar un total de 6 dispositivos de se alizaci n remotos y o m dulos de rel Consulte la p gina 16 para obtener detalles sobre la inter conexi n de dispositivos Kidde La distancia m xima del tendido de cables entre la primera y la ltima unidad en un sistema
34. anchada presione la leng eta y gire la alarma hasta sacarla del soporte consulte la Figura 5B FIGURA 5 FIGURA 5B Ubicaci n de los terminales lt Qu hacer si suena la alarma iNUNCA IGNORE EL SONIDO DE LA ALARMA Es f cil determinar qu tipo de alarma son con la alarma com binada contra humo mon xido de carbono Nighthawk El sis tema de advertencia de mensaje de voz le informar el tipo de situaci n que se est produciendo Consulte la secci n Caracter sticas en las p ginas 4 7 para obtener una descripci n detallada de cada patr n de alarma Qu hacer si suena la alarma Cuando suena la alarma contra humo Las alarmas contra humo est n dise adas para reducir al m ni mo las falsas alarmas El humo de cigarrillo normalmente no la activar a menos que llegue directamente a la alarma Las part culas por combusti n provenientes de la cocina pueden activar la alarma si est ubicada demasiado cerca del rea en que se cocina Se generan grandes cantidades de part culas combustibles por derrames o al asar El uso del ventilador de una campana de cocina que expulsa el aire hacia el exterior que no sea de recirculaci n tambi n ayuda a eliminar estos productos combustibles de la cocina Si la alarma suena primero verifique si hay un incendio Si des cubre un incendio siga estos pasos jFamiliaricese con estos puntos y rev selos con todos los miembros de su familia Alerte a los
35. ble la insta ues laci n en cielo raso Al instalar una alarma en AQUIES el cielo raso ACEPTABLE col quela a una dis tancia m nima de 4 pulg 10 cm de la pared lateral consulte la Figura 1 Si instala 8 FIGURA 1 Instrucciones de instalaci n la alarma en la pared use una pared interior con el borde supe rior de la alarma a un m nimo de 4 pulg 10 cm y un m ximo de 12 pulg 30 5 cm bajo el cielo raso consulte la Figura 1 Instalaci n en un techo con pendiente La siguiente informaci n la proporciona la Asociaci n Nacional de Protecci n contra Incendios y se indica en el C digo de incendios 72 Instale alarmas contra humo en cielos rasos en pendiente a dos vertientes o catedral a 3 pies 0 9 m o menos del punto m s alto en 8 pies 0 3 m a 2 4 m medido horizontalmente se deben ubicar en el lado m s alto de la habitaci n La NFPA 72 se ala que las alarmas en hilera deben estar sepa radas y ubicadas a menos de 3 pies 0 9 m del v rtice del cielo raso medido horizontalmente Consulte la Figura 2 AREA EN CUALQUIER LUGAR DENTRO DE ESTA AREA 4 102m FIGURA 2 Casas rodantes Las casas rodantes modernas han sido dise adas y construidas para lograr un uso eficiente de la energ a Instale las alarmas contra humo mon xido de carbono seg n las recomendaciones anteriores Consulte las Instrucciones de instalaci n recomen dadas y la Figura 1 En casas
36. ciones de puesta en funcionamiento CONDICI N DE MEMORIA DE ALARMA El LED destellar a cada segundo lo que significa que la alarma detect un riesgo de humo o de mon xido de carbono Seguir destellando a cada segundo hasta que se presione el bot n probar restablecer para restablecer la alarma CONDICI N DE MODO DE SILENCIADOR El LED destel lar cada 2 segundos mientras la alarma se encuentre en modo de silenciador Caracter stica de protecci n contra la manipu laci n indebida Su alarma contra humo mon xido de carbono viene con una caracter stica de protecci n contra la manipulaci n indebida Active la caracter stica de protecci n contra la manipulaci n indebida desprendiendo los cuatro terminales de tornillo de los orificios cuadrados del anillo de ajuste consulte la Figura 5A Una vez que se haya desprendido los terminales de tornillo es posible enganchar la leng eta de protecci n contra la manipu laci n indebida que se ubica en la base al soporte de montaje Haga girar la alarma en el soporte de montaje hasta que escuche el enganche de la leng eta de protecci n contra la manipulaci n indebida en su lugar lo que bloquea la alarma en el soporte de montaje Esta caracter stica de protecci n contra la manipulaci n indebida ayuda a evitar que los ni os y otras personas saquen la alarma del soporte NOTA Para retirar la alarma cuando la leng eta de protecci n contra la manipu laci n indebida est eng
37. con pulsa ciones somnolencia confusi n ritmo card aco acelera do 3 Exposici n extrema Inconsciencia convulsiones paro cardiorespiratorio muerte Los niveles anteriores de exposici n est n relacionados con adul tos saludables Los niveles difieren para quienes est n en alto riesgo La exposici n a altos niveles de mon xido de carbono puede ser fatal o provocar da os e incapacidades permanentes Muchas v ctimas de intoxicaci n por mon xido de carbono indi can que aunque estaban conscientes de que estaban enfermas se sintieron tan desorientadas que no fueron capaces de ayudarse a s mismas saliendo del edificio o pidiendo ayuda Recuerde los ni os y las mascotas pueden ser los primeros afec tados Es importante familiarizarse con los efectos de cada nivel 27 Normas de seguridad de la industria Plan de escape Haga que todos se familiaricen con el sonido de la alarma con tra humo y capac telos para que salgan de la casa cuando lo escuchen Lleve a cabo un simulacro de incendio cada seis meses por lo menos tambi n debe incluir simulacros noc turnos Aseg rese de que los ni os peque os escuchen la alar ma y que despierten cuando sta suene ya que deben desper tar para ejecutar el plan de escape Esta pr ctica permite que todos los ocupantes prueben su plan ante una emergencia Es posible que no pueda llegar donde est n los ni os Es impor tante que usted sepa qu hacer Tenga conocimiento
38. e alarm in the direction of the OFF arrow on the cover To dis connect the AC power harness squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bottom of the alarm see page 13 figure 4 Battery Replacement For model KN COSM IB only If any form of battery failure is detected the red LED light will flash and the unit will chirp one time followed by the warn ing message LOW BATTERY This cycle will occur once every minute and will continue for at least seven days If the red LED light flashes along with a chirp every 30 seconds and is not followed by the voice message LOW BATTERY as described above your unit has malfunc tioned Call our toll free Consumer Hotline at 1 800 880 6788 for instructions on how to return the unit 21 Alarm Removal and Battery Replacement CAUTION YOUR SMOKE CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE To replace the battery you must first remove the alarm from the mounting bracket by following the ALARM REM OVAL instruc tions at the beginning of this section After the alarm has been removed you can open the battery door and replace the bat tery Battery installation instructions are provided on the inside of the battery door FIGURE 6 Battery Replacement When installing the battery press the battery reminder finger down into the battery compartment and install the battery see figure 6 CAUTION I
39. e connector snap into place Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket Install the alarm on the mounting bracket and rotate the alarm in the direction of the ON arrow on the cover until the alarm ratchets into place this ratcheting function allows for aesthetic alignment Note The alarm will mount to the bracket in 4 positions every 90 degrees 13 Installation Instructions 7 on the AC power The green AC Power On Indicator should be lit when the alarm is operating from AC power 8 Two labels are included with your alarm They have impor tant information on what to do in case of an alarm Add the phone number of your emergency service provider Fire Department or 911 in the space provided Place one label next to the alarm after it is mounted and one label near fresh air source such as a door or window 9 For model KN COSM IB only Pull the Battery Pull Tab yellow tab protruding from unit completely out of unit This will automatically connect the battery Step 4 Testing the Alarm CAUTION Due to the loudness 85 decibels of the alarm always stand an arms length away from the unit when testing The test reset button has four purposes It tests the unit s elec tronics resets the CO alarm activates the HUSH feature and activates the Peak Level M emory Feature After installation TEST THE UNIT S ELECTRONICS by pressing and relea
40. ecci n Las alarmas de detecci n de ionizaci n pueden detectar part culas de humo invisibles asociadas a incendios de expansi n r pida m s r pido que las alarmas fotoel ctric as Las alarmas de detecci n fotoel ctricas pueden detectar part culas de humo visibles asociadas a incendios de expan si n lenta m s r pido que las alarmas de ionizaci n Los incendios en las casas se pueden producir de diferentes for mas y con frecuencia son impredecibles Kidde recomienda que para una m xima protecci n se instalen alarmas de ion izaci n y fotoel ctricas Caracter sticas de la alarma contra humo Una alarma alimentada por bater as debe tener una bater a del tipo especificado en buenas condiciones e instalada ade cuadamente Una alarma alimentada por bater as debe tener una bater a del tipo especificado en buenas condiciones e instalada ade cuadamente Las alarmas contra humo se deben probar regularmente para asegurarse de que las bater as y los circuitos de alarma est n en buenas condiciones de funcionamiento Las alarmas contra humo no pueden dar la alarma si el humo no llega a ellas Por lo tanto es posible que estas alarmas no detectenincendios que se inicien en chimeneas paredes techos al otro lado de una puerta cerrada o en otro piso Si la alarma esta ubicada fuera del dormitorio o en otro piso es posible que no despierte a una persona de sue o profun do El uso de alco
41. ecci n de cualquier otra marca 15 Instrucciones de puesta en funcionamiento Esta alarma admite la interconexi n con las siguientes alarmas y accesorios Alarmas contra humo 12020 112040 112060 112080 1235 1275 1276 1285 1296 PE120 PI2000 KN COSM IB KN COSM I y RF SM ACDC Alarma de calor HD135F Alarmas contra mon xido de carbono KN COB IC KN COP IC M dulos de rel s 120X SM120X CO120X Luz estrobosc pica 511771 Consulte las Gu as del usuario para encontrar informaci n espec fica acerca de cada aplicaci n Para obtener mayor informaci n sobre las unidades de inter conexi n compatibles y su funcionalidad en un sistema inter conectado visite nuestro sitio Web en www kidde com Funci n de control de silenciador La funci n de silenciador tiene la capacidad de insensibilizar temporalmente el circuito de la alarma durante aproximada mente 10 minutos Esta funci n s lo se debe usar cuando una condici n de alarma conocida como humo proveniente de la cocina activa la alarma Puede poner la alarma contra humo mon xido de carbono en el modo de silenciador presion ando el bot n probar restablecer Si el humo no es demasiado denso la alarma se silenciar inmediatamente la unidad anun ciara verbalmente SE ACTIVO EL MODO DE SILENCIA DOR y el LED verde destellar cada 2 segundos durante aproximada mente 10 minutos Esto indica que la alarma contra humo se encuentr
42. er s guide and save for future reference Teach children how to respond to the alarms and that they should never play with the unit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combus tion in a residential environment It is not designed for use in a recreational vehicle RV or boat If you have any questions about the operation or installation of your alarm please call our toll free Consumer Hotline at 1 800 880 6788 The guide on Page 27 will help you determine the correct location of safety products that will help keep your home a safer place Product View TEST RESET RED LED HUSH BUTTON Light Emitting Diode SMOKE AND CARBON MONOXIDE ALARM ALARM GREEN LED SOUNDER Light Emitting Diode Product View TAMPER RESIST FEATURE AC CONNECTOR BATTERY PINS COMPARTMENT Model KN COSM IB Only Features Loud 85 decibel alarm Permanent independent smoke and carbon monoxide sensors Smoke alarm takes precedence when both smoke and carbon monoxide are present Powered by 120V AC 60 Hz 25 max wire in connector Model KN COSM IB is also equipped with a 9V battery back up e Model KN COSM IB is equipped with Battery Pull Tab that allows for easy battery connection Simply pull tab out and battery is connected nterconnectable to other Kidde Nighthawk brand smoke and CO alarms see page 16 for details Alarm Voice m
43. erales y los pasillos no protegidos por las alarmas contra humo requeridas Por lo general no se recomienda la instalaci n de alarmas contra humo en cocinas ticos terminados y no terminados o garajes ya que estos lugares ocasionalmente experimentan condiciones que pueden dar como resultado un funcionamiento inadecuado Jefe de bomberos del estado de California La detecci n temprana de una advertencia de incendio se logra mejor mediante la instalaci n de equipos de detecci n de incendios en todas las habitaciones y reas de la vivienda de la siguiente manera Una alarma contra humo instalada en cada rea para dormir separada en las proximidades pero fuera de los dormitorios detectores de calor o humo en comedores liv ings dormitorios cocinas pasillos ticos reas destinadas a la calefacci n cl sets reas destinadas a los servicios generales y despensas s tanos y garajes adyacentes 29 Garant a Comisi n para la Seguridad de los Productos de Consumo La Comisi n para la Seguridad de los Productos de Consumo CPSC recomienda el uso de por lo menos una alarma contra mon xido de carbono por vivienda ubicada cerca del rea de dormitorios NRC Las alarmas contra humo de ionizaci n usan una peque a can tidad de un elemento radiactivo en la c mara de detecci n para permitir la detecci n de productos de combusti n visibles e invisibles El elemento radiactivo est guardado en forma segura en la c
44. essage warning system that alerts you of the ollowing conditions in the manner described below thus eliminating any confusion over which alarm is sounding FIRE The alarm voice pattern is three long alarm beeps fol lowed by the verbal warning message FIRE FIRE This pat tern is repeated until the smoke is eliminated The red LED light will flash while in alarm voice mode CARBON MONOXIDE The alarm voice pattern is four short alarm beeps followed by the verbal warning message WARNING CARBON MONOXIDE This continues until the unit is reset or the CO eliminated While powered by battery only after four minutes the alarm voice pattern will sound once every minute The red Light Emitting Diode LED light will flash while in alarm voice mode LOW BATTERY model KN COSM IB only When the bat teries are low and need replacing the red LED light will flash and the unit will chirp one time followed by the warning message LOW BATTERY This cycle will occur once every minute and will continue for at least seven days Features Voice Message System that alerts user to the following condi tions System announces HUSH M ODE ACTIVATED when the unit is first put into HUSH Mode System announces HUSH MODE CANCELLED when unit resumes normal operation after Hush Mode has been cancelled System announces CARBON M ONOXIDE PREVIOUSLY DETECTED when the unit has detected CO concentrations of 10
45. haust fans simultaneous operation of several fuel burning appliances competing for limited internal air vent pipe connec tions vibrating loose from clothes dryers furnaces or water heaters obstructions in or unconventional vent pipe designs which can amplify the above situations extended operation of unvented fuel burning devices range oven fireplace etc temperature inversions which can trap exhaust gasses near the ground car idling in an open or closed attached garage or near a home CO Safety Tips Every year have the heating system vents chimney and flue inspected and cleaned by a qualified technician Always install appliances according to manufacturer s instructions and adhere to local building codes Most appliances should be installed by professionals and inspected after installation Regularly exam ine vents and chimneys for improper connections visible rust or stains and check for cracks in furnace heat exchangers Verify the color of flame on pilot lights and burners is blue A yellow or orange flame is a sign that the fuel is not burning completely Teach all household members what the alarm sounds like and how to respond Symptoms of CO Poisoning Initial carbon monoxide poisoning symptoms are similar to the flu with no fever and can include dizziness severe headaches nausea vomiting and disorientation Everyone is susceptible but experts agree that unborn babies pregnant women senior citi zens and peop
46. hen something is burning or smoldering When smoke particles in the smoke sensor reach a specified concentration the alarm voice message warning system will sound and be accompanied by the flashing red LED light The smoke alarm takes precedence when both smoke and carbon monoxide are present WARNING PLEASE READ CAREFULLY AND THOROUGHLY NFPA 72 states Life safety from fire in residential occupancies is based primarily on early notification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or young or physically or mentally impaired such that they cannot escape even when warned early enough that escape should be possi ble For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost however alarms have sens ing limitations lonization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ionization alarms Home fires develop in different ways and are often unpredictable For maximum protection K
47. hol o drogas tambi n puede disminuir la capaci dad de escuchar la alarma Para una maxima protecci n se debe instalar una alarma en cada area de dormitorios y en cada piso de una casa e Aunque las alarmas contra humo pueden ayudar a salvar vidas al advertir oportunamente de un incendio no son un sustituto de una p liza de seguro Los propietarios y arren datarios deben contratar un seguro adecuado para proteger su vida y su propiedad Alarma contra mon xido de carbono CO La alarma contra mon xido de carbono CO supervisa la pres encia de mon xido de carbono en el aire Se activar ante nive les altos y bajos de mon xido de carbono durante un per odo prolongado Consulte la p gina 22 para conocer los tiempos de alarma Cuando una condici n de mon xido de carbono corresponda a una de estas situaciones sonar el sistema de advertencia de mensaje de voz alarma junto con el LED rojo destellante El sensor de mon xido de carbono usa una tec nolog a electroqu mica PRECAUCI N Esta alarma s lo indicar la presencia de gas de mon xido de carbono en el sensor El gas de mon xido de carbono puede estar presente en otras reas Las personas con problemas m dicos pueden considerar el uso de dispositivos que entreguen se ales sonoras y visuales para las concentraciones de mon xido de carbono de menos de 30 PPM 7 Instrucciones de instalaci n Paso 1 Gu a de instalaci n IMPORTANTE ESTA ALARMA SE DEB
48. ida u otros seguros de cualquier clase La cobertura de un seguro apropiado es su responsabilidad Consulte a su agente de seguros El retiro de la cubierta delantera anula la garant a Esta alarma no est dise ada para alertar a personas con discapaci dad auditiva Durante el per odo de garant a especificado Kidde Products reparar o reemplazar a su discreci n toda alarma combinada contra humo y mon xido de carbono Nighthawk que sea devuelta en un paquete con el franqueo pagado a la siguiente direcci n Kidde Products Attn Warranty Returns 1016 Corporate Park Dr Mebane NC 27302 USA Incluya su nombre direcci n y n mero de tel fono junto con una breve descripci n del problema que experimenta la alarma Para obtener m s ayuda ll menos en forma gratuita a la l nea directa para el consumidor al 1 800 880 6788 Los da os debidos a negligencia mal uso o desatenci n a las instrucciones incluidas dar como resultado el t rmino de la garant a y por consiguiente no se reemplazar ni reparar la unidad Registro del producto Este manual y los productos descritos est n registrados con todos los derechos reservados Seg n estas leyes de propiedad intelectual ninguna parte de este manual se puede copiar para su uso sin el consentimiento escrito de Kidde Si necesita informaci n adicional p ngase en contacto con la l nea directa para el consumidor al 1 800 880 6788 o escr banos a Kidde Products 1016 Corp
49. idde recommends that both lonization and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly Features and General Information AC powered alarms without battery backup will not operate if the AC power has been cut off such as by an electrical fire or an open fuse Smoke alarms must be tested regularly to make sure the bat teries and the alarm circuits are in good operating condition Smoke alarms cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor If the alarm is located outside the bedroom or on a different floor it may not wake up a sound sleeper The use of alcohol or drugs may also impair ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in each sleeping area on every level of a home Although smoke alarms can help save lives by providing an early warning of a fire they are not a substitute for an insur ance policy Home owners and renters should have adequate insurance to protect their lives and property Carbon Monoxide CO Alarm The Carbon Monoxide CO alarm monitors the air for the pres ence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of ti
50. ility in tort or otherwise The Manufacturer shall have no liability for any personal injury property damage or any special incidental contingent or con sequential damage of any kind resulting from gas leakage fire or explosion Since some states do not allow limitations of the duration of an implied warranty or do not allow the exclusion or limitation of incidental or consequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have other rights which vary from state to state Also KIDDE makes no warranty express or implied written or oral including that of merchantability or fitness for any particu lar purpose with respect to the battery 29 Warranty and Service Information The above warranty may not be altered except in writing signed by both parties hereto Your Nighthawk Combination Smoke amp CO Alarm is not a sub stitute for property fire disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Removal of the front cover will void the warranty This alarm is not intended to alert hearing impaired indi viduals During the specified w arranty period Kidde Products will repair or replace at its discretion any defective Nighthawk Combination Smoke amp CO Alarms that are returned in a postage paid package to the following address Kidde Products
51. informaci n adicional consulte la secci n Reemplazo de la alarma 2 Retire el soporte de montaje de la parte posterior de la alarma sosteni ndolo y girando la alarma en la direcci n que indica la flecha OFF en la cubierta de la alarma 3 Despu s de seleccionar la ubicaci n adecuada para la alarma contra humo mon xido de carbono como se describe en las p ginas 8 11 y de conectar los cables de CONEXI N R PIDA de CA seg n se describe en las INSTRUCCIONES DE CABLEA DO conecte el soporte de montaje a la caja el ctrica Para ase gurarse de que la alarma est alineada con el pasillo o la pared la l nea A del soporte de montaje debe estar paralela 13 Instrucciones de instalaci n al pasillo cuando se instala en el cielo raso u horizontal cuando se instala en la pared 4 Introduzca el CONECTOR R PIDO DE CA por el orificio central del soporte de montaje y fije el soporte asegur ndose que los tornillos de montaje est n ubicados en los extremos peque os de los orificios de agarre antes de apretar los tornillos 5 Conecte el CONECTOR R PIDO lee 7 de parte posterior de la an alarma consulte la Figura 4 Y i gt asegur ndose de que los y i enganches del conectorencajen en su lugar Luego ponga de nuevo el cable sobrante en la caja el ctrica a trav s del orificio i que se encuentra en el centro FIGURA 4 INSTALACI N DE del soporte de montaje LA C
52. ins a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow ares Avoid excessively dusty dirty or greasy areas Dust grease or household chemi cals can contaminate the alarm s sensors causing it to not operate properly Place the alarm where drapes or other objects will not block the sensor Smoke and CO must be able to reach the sensors to accurately detect these conditions Do not install in peaks of vaulted ceilings A frame ceilings or gabled roofs Keep out of damp and humid areas Install at least one 1 foot away from fluorescent lights elec tronic noise may cause nuisance alarms Do not place in direct sunlight and keep out of insect infested areas Extreme temper atures will effect the sensitivity of the Smoke CO Alarm Do not install in areas where the temperature is colder than 40 degrees Fahrenheit 4 4 Celsius or hotter than 100 degrees Fahrenheit 37 8 Celsius such as garages and unfinished attics Do not install in areas where the relative humidity RH is above 85 Place away from doors and windows that open to the outside 10 Installation Instructions Step 2 Wiring Instructions WIRING REQUIREMENTS e This smoke alarm should be installed on a U L listed or rec ognized junction box All connections should be made by a qualified electrician and all wiring used shall be in accordance with articles 210 and 300 3 B of the U S
53. ionadas con su alarma contra humo y mon xido de carbono llamea nuestra l nea directa para el consumidor al 1 800 880 6788 Para su comodidad escriba la siguiente informaci n Si llama a nuestra l nea directa de asistencia para el consumidor stas son las primeras preguntas que se le formular n N mero de modelo de la alarma ubicado en la parte posterior de la alarma Fecha de fabricaci n ubicada en la parte posterior de la alarma Fecha de compra Lugar de compra LE DO Y AHORRAR ESTO GU A DEL USUARIO Manual P N 810 1512 Rev H Table of Contents Introducci n Au P gina 1 Vista del producto P ginas 2 3 Caracteristicas 4 7 Instrucciones instalaci n Paso 1 Instrucciones de instalaci n A Ubicaciones de instalaci n recomendadas P ginas 8 10 B Donde 10 Paso 2 Instrucciones de cableado Paso 3 Instrucciones de montaje P ginas 13 14 Paso 4 Prueba de la P gina 15 Instrucciones de puesta en funcionamiento Caracter stica de interconexi n P gina 15 Funci n de control de silenciador HUSH P ginas 15 16 Funci n restablecer P gina 16 Memoria de nivel m xim0
54. ir spray after shave per fume and some cleaning agents Carbon Monoxide Safety Information General CO Information Carbon monoxide CO is a colorless odorless and tasteless poison gas that can be fatal when inhaled CO inhibits the blood s capacity to carry oxygen Possible Sources CO can be produced when burning any fossil fuel gasoline propane natural gas oil and wood It can be produced by any fuel burning appliance that is malfunctioning improperly installed or not ventilated correctly Possible sources include fur naces gas ranges stoves gas clothes dryers water heaters portable fuel burning space heaters fireplaces wood burning stoves and certain swimming pool heaters Blocked chimneys or flues back drafting and changes in air pressure corroded or dis connected vent pipes and a loose or cracked furnace exchanger can also cause CO Vehicles and other combustion engines run ning in an attached garage and using a charcoal gas grill or hibachi in an enclosed area are all possible sources of CO The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind heavy air in the 24 Carbon Monoxide Safety Information vent pipes cold humid air with extended periods between cycles negative pressure differential resulting from the use of ex
55. is recommended that the householder consider the use of additional smoke alarms for those areas for increased protec tion The additional areas include the basement bedrooms din ing room furnace room utility room and hallways not protect ed by the required smoke alarms The installation of smoke alarms in kitchens attics finished or unfinished or garages is not normally recommended as these locations occasionally experience conditions that can result in improper operation California State Fire Marshall Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the house hold as follows A smoke alarm installed in each separate sleeping area in the vicinity but outside the bedrooms heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached garages Consumer Product Safety Commission The Consumer Product Safety Commission CPSC recommends the use of at least one CO Alarm per household located near the sleeping area NRC lonization type smoke alarms use a very small amount of a radioactive element in the sensing chamber to enable detection of visible and invisible combustion products The radioactive ele ment is safely contained in the chamber and requires no adjust ments or maintenance This smoke alarm meets or exceeds all government standards
56. l horario de ver ano Reemplazo de la alarma Despu s de siete a os del encendido inicial esta unidad emitir un chirrido cada 30 segundos para indicar que es tiempo de reemplazar la alarma Se proporciona una etiqueta en el costa do de la alarma que tiene Replace by Reemplazar antes del impreso Escriba la fecha de reemplazo en la etiqueta La fecha debe ser la equivalente a siete 7 a os de encendido continuo REEMPLAZAR INM EDIATAM ENTE NO DETECTAR EL MONOXIDO DE CARBONO EN ESTA CONDICION Para mantener su alarma contra humo mon xido de carbono en buenas condiciones de funcionamiento siga estos sencillos pasos e Verifique el funcionamiento de la alarma y los LED de la unidad al presionar el bot n probar restablecer una vez por semana Retire la unidad del soporte de montaje y aspire la cubierta de la alarma y los orificios de ventilaci n con un accesorio de escobilla suave una vez al mes para eliminar el polvo y la suciedad VUELVA A INSTALARLA INM EDIATAM ENTE DESPUES DE LIMPIARLA Y LUEGO PRUEBELA USANDO EL BOT N PROBAR RESTABLECER Nunca use detergentes ni otros solventes para limpiar la unidad e Evite rociar desodorantes ambientales aerosol para el pelo u otros aerosoles cerca de la alarma contra humo mon xido de carbono No pinte la unidad La pintura obstruye los orificios de ventilaci n e interfiere con la capacidad del sensor de detectar humo y mon xi do de carbono N
57. le with heart or respiratory problems are especial ly vulnerable If symptoms of carbon monoxide poisoning are experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test The following symptoms are related to CARBON MONOXIDE POISONING and should be discussed with ALL members of the household 25 Carbon Monoxide Safety Information 1 Mild Exposure Slight headache nausea vomiting fatigue often described as Flu like symptoms 2 Medium Exposure Severe throbbing headache drowsiness confusion fast heart rate 3 Extreme Exposure Unconsciousness convulsions cardiorespiratory failure death The above levels of exposure relate to healthy adults Levels dif fer for those at high risk Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and disabil ities Many cases of reported carbon monoxide poisoning indi cate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first effected Familiarization with the effects of each level is important Fire Safety Information Escape Plan Familiarize everyone with the sound of the smoke alarm and train them to leave the home when they hear it Practice a fire drill at least every six months including fire drills at night Ensure that s
58. mall children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Know two ways out of every room door amp window and identify a meeting place outside the home where everyone will gather once they have exited the res idence When two people have reached the meeting place one should leave to call 911 while the second person stays to account for additional family members Establish a rule that once you re out you never reenter under any circumstance Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individu als in the household that are capable of assisting others to pro vide assistance to those who may not be awakened by the alarm sound or to those who may be incapable of safely evacu ating the area unassisted 26 Fire Safety Information Fire Prevention ete Never smoke in bed or leave cooking food unattended Teach children never to play with matches or lighters Train everyone in the home to recognize the alarm pattern Je voice message warning and to leave the home using their escape plan when it s heard FIRE EXTI
59. me see page 21 for alarm times When a CO condition matches either of these situations the alarm voice message warning system will sound and be accompanied by the flashing red LED light The carbon monoxide sensor uses an electrochemical technology CAUTION This alarm will only indicate the presence of carbon monoxide gas at the sensor Carbon monoxide gas may be present in other areas Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30 ppm Installation Instructions Step 1 Installation Guide IMPORTANT THIS ALARM MUST BE MOUNTED ON A CEILING OR WALL IT WAS NOT DESIGNED FOR USE AS A TABLETOP DEVICE INSTALL ONLY AS DETAILED A Recommended Installation Locations Kidde Safety recommends the installation of a Smoke CO Alarm in the following locations For maximum protection we suggest an alarm be installed on each level of a multilevel home includ ing every bedroom hallways finished attics and basements Put alarms at both ends of bedroom hallway or large room f hall way or room is more than 30 ft 9 1m long If you have only one alarm ensure it is placed in the hallway outside of the main sleeping area or in the main bedroom Verify the alarm can be heard in all sleeping areas Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room fr
60. n xido de carbono inhibe la capacidad de la sangre de transportar ox geno Posibles fuentes El mon xido de carbono se puede producir al quemar cualquier combustible f sil gasolina propano gas natural petr leo y le a Se puede producir por el mal funcionamiento instalaci n o venti laci n inadecuadas de un aparato quemador de combustible Las fuentes posibles incluyen hornos cocinas hornillos a gas secado ras de ropa a gas hervidores estufas quemadoras de com bustible port tiles chimeneas de le a cocinas a le a y algunos calentadores de piscinas Tambi n pueden producir mon xido de carbono las chimeneas y ca ones bloqueados contratiros y 25 Informaci n de seguridad sobre el monoxido de carbono cambios en la presi n del aire tubos de ventilaci n corro dos o desconectados un termointercambiador de caldera suelto o agrieta do Los veh culos y otros motores de combusti n en funcionamiento en un garaje adyacente o el uso de una parrilla de carb n vegetal gas o parrilla port til en un rea cerrada tambi n son posi bles fuentes de mon xido de carbono Las siguientes condiciones pueden dar como resultado situaciones transitorios de mon xido de carbono transitorio el derrame excesivo o la ventilaci n invertida de aparatos que madores de combustible causado por condiciones ambientales externas como la direcci n velocidad del viento lo que incluye grandes r fagas de viento el aire pesado en l
61. nstall Smoke CO alarms as recommended above refer to Recommended Installation Instructions and fig ure 1 In older mobile homes that are not well insulated extreme heat or cold can be transferred from the outside to the inside through poorly insulated walls and roof This may cause a thermal barrier which can prevent smoke from reaching an alarm mounted on the ceiling In such mobile homes install your Smoke CO Alarm on an inside wall with the top edge of the alarm at a minimum of 4 inches 10cm and a maximum of 12 inches 30 5cm below the ceiling see figure 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install your alarm on an inside wall ONLY Installation Instructions THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STANDARD 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 WARNING This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standards B Where Not to Install Do not install in garages kitchens furnace rooms or bath rooms INSTALL AT LEAST 5 FEET AWAY FROM ANY FUEL BURNING APPLIANCE Do not install within 3 ft 9m of the following The door to a kitchen or a bathroom that conta
62. o supervisa el en caso de que existan pro ductos de combusti n provenientes de algo que se est que mando o ardiendo sin llama Cuando las part culas de humo alcanzan una concentraci n especificada suena el sistema de advertencia de mensaje de voz alarma y se enciende el LED rojo destellante La alarma contra humo tiene prioridad cuando haya presencia de humo y mon xido de carbono ADVERTENCIA LEA ATENTA Y COMPLETAMENTE LO SIGUIENTE La NFPA 72 se ala que la seguridad de las personas en caso de incendio en edificios residenciales se basa principalmente en el aviso oportuno a los ocupantes de la necesidad de salir de inmediato seguido de las medidas de desalojo adecuadas que tomen dichos ocupantes Los sistemas de advertencia de incen dios para las unidades residenciales pueden proteger aproxi madamente a la mitad de los ocupantes en incendios potencial mente fatales Las v ctimas son a menudo personas que est n muy cerca del fuego ancianos o ni os o personas con dis capacidad mental o f sica quienes no pueden escapar incluso cuando se les advierte con suficiente anticipaci n como para que puedan salir Para estas personas son necesarias otras estrategias como la protecci n en el mismo lugar o bien la sal ida o el rescate asistido Las alarmas contra humo son dispositivos que pueden entre gar una advertencia oportuna de posibles incendios a un costo razonable sin embargo las alarmas tienen limitaciones de det
63. om waking the sleeper Smoke heat and com bustion products rise to the ceiling and spread horizontally Mounting the alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction When mounting an alarm on the ceil ing locate it at a minimum of 4 CEILING Minimum 10cm from the side wall see figure 1 If installing the alarm Z on the wall use an inside wall with the top edge of the alarm at a minimum of 4 10cm and a ACCEPTABLE gt maximum of 12 HEIE 30 5cm below the ceiling see figure 1 DEAD AIR SPACE FIGURE 1 Installation Instructions Sloped Ceiling Installation The following information is from the National Fire Protection Association and is listed in Fire Code 72 Install Smoke Alarms on sloped peaked or cathedral ceilings at or within 3 ft 0 9m of the highest point measured horizontal ly NFPA 72 states Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft 3 m 2 4 m horizontally shall be locat ed on the high side of the room NFPA 72 states A row of alarms shall be spaced and located within 3 ft 0 9 m of the peak of the ceiling measured horizon tally see figure 2 NOT IN THIS ANYWHERE AREA IN THIS AREA Feroz tam FIGURE 2 Mobile Homes Modern mobile homes have been designed and built to be energy efficient I
64. ons A maximum of 24 Kidde Safety devices may be interconnect ed in a multiple station arrangement The interconnect sys tem should not exceed the NFPA interconnect limit of 12 smoke alarms and or 18 alarms total smoke CO Smoke CO Combination heat This Smoke CO combination alarm must be counted as a smoke alarm when determining the number of units on an interconnect line With 18 alarms interconnected it is still possible to interconnect up to a total of 6 remote signaling devices and or relay modules see page 16 for details on interconnecting Kidde devices The maximum wire run distance between the first and last unit in an interconnected system is 1000 feet Figure 3 illustrates interconnection wiring Improper connec tion will result in damage to the alarm failure to operate or a shock hazard Make certain alarms are wired to a continuous non switched power line NOTE Use standard UL Listed household wire as required by local codes available at all electrical supply stores and most hardware stores FUSE OR CIRCUIT BREAKER Ti EXA ES Relay Module suo First Additional f Optical Alarm Alarm Accessory FIGURE 3 Interconnect Wiring Diagram WIRES ON ALARM HARNESS CONNECTED TO Black Hot Side of AC Line White Neutral Side of AC Line Red Interconnect Lines Red Wires of Other Units in the Multiple Station Se
65. orate Park Dr Mebane NC 27302 Nuestra direcci n en Internet es www kidde com 31 L nea directa para el consumidor 1 800 880 6788 www kidde com F Kidde Kidde 1016 Corporate Park Drive Mebane NC 27302 Ensamblada en China con componentes estadounidenses y de otros paises
66. os tubos de venti laci n aire frio h medo con per odos extendidos entre ciclos el diferencial negativo de presi n provocado por el uso de venti ladores eductores el funcionamiento simult neo de varios aparatos quemadores de combustible que compiten por el aire interno limi tado las conexiones de tubos de ventilaci n sueltas de las secado ras de ropa las calderas o calentadores de agua obstrucciones o dise os de tuber as de ventilaci n no convencionales que pueden acentuar las situaciones anteriores el funcionamiento prolongado de dispositivos quemadores de combustible sin orificios de venti laci n hornillo caldera chimenea etc las inversiones de temper atura que pueden atrapar gases de escape cerca del suelo y la marcha en ralent de un autom vil en un garaje adyacente abierto o cerrado o cerca de la casa Consejos de seguridad sobre el mon xido de carbono Cada a o solicite a un t cnico calificado que inspeccione y limpie el sistema de calefacci n los orificios de ventilaci n la chimenea y el ca n Instale siempre los aparatos de acuerdo con las instrucciones del fabricante y los c digos de construc ci n locales La mayor a de los aparatos deben ser instalados por profesionales y se deben inspeccionar despu s de la insta laci n Examine regularmente los orificios de ventilaci n y las chimeneas para ver si hay conexiones inadecuadas herrumbre visible o decoloraciones y verifique si hay hendiduras en
67. peration by pushing the test reset button once a week Remove the unit from mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt REINSTALL IMMEDIATELY AFTER CLEANING AND THEN TEST USING THE TEST RESET BUTTON Never use detergents or other solvents to clean the unit Avoid spraying air fresheners hair spray or other aerosols near the Smoke CO Alarm Do not paint the unit Paint will seal the vents and interfere with the sensor s ability to detect smoke and CO Never attempt to disassemble the unit or clean inside This action will void your warranty Move the Smoke CO Alarm and place in another location prior to performing any of the following Staining or stripping wood floors or furniture Painting Wall papering e Using adhesives 23 General Maintenance Storing the unit in a plastic bag during any of the above proj ects will protect the sensors from damage Do not place near a diaper pail WARNING Reinstall the Smoke CO Alarm as soon as possible to assure continuous protection When household cleaning supplies or similar contaminates are used the area must be well ventilated The following sub stances can effect the CO sensor and may cause false readings and damage to the sensor M ethane propane iso butane iso propanol ethyl acetate hydrogen sulfide sulfide dioxides alcohol based products paints thinner solvents adhesives ha
68. ponsable por p rdidas derivadas del uso de este producto ni de ning n da o costo o gasto indi recto especial o incidental en que pueda incurrir el consumidor o cualquier otro usuario de este producto ya sea debido a violaci n del contrato negligencia responsabilidad objetiva u otros El fabricante no tendr responsabilidad alguna en caso de lesiones personales da os a la propiedad o cualquier otro da o especial incidental o condicional de 30 Garant a ning n tipo provocado por filtraciones de gas incendio o explosi n Puesto que en algunos estados no se reconocen las limitaciones de la duraci n de una garant a impl cita o no se reconoce la exclusi n o lim itaci n de da os fortuitos o indirectos las limitaciones o exclusionesante riores pueden no corresponder a su caso A pesar de que esta garant a le otorga derechos legales espec ficos usted tambi n puede tener otros derechos que var an de un estado a otro Adem s KIDDE no entrega ninguna garant a expresa o impl cita escrita u oral lo que incluye aquella relacionada con la comercializaci n o la idoneidad para un prop sito en particular con respecto a la bater a La garant a anterior no se puede alterar salvo que se haga por escrito y que tenga la firma de ambas partes involucradas La alarma combinada contra humo y mon xido de carbono Nighthawk no es un sustituto de los seguros de da os a la propiedad contra incen dios de incapacidad de v
69. r Paso 2 Instrucciones de cableado REQUISITOS DE CABLEADO Esta alarma contra humo debe instalarse en una caja de conexiones registrada o UL homologada Todas las conexiones deben realizarse por un electricista calificado y el cableado debe realizarse de acuerdo a lo establecido en los art culos 210 y 300 3 B del C digo de Electricidad Nacional de EE UU ANSI NFPA 70 NFPA 72 y o cualquier otro c digo aplicable en su area El cableado para interconectar esta ciones multiples a las alarmas debe pasar por el mismo con ducto el ctrico o cable que el cableado de alimentaci n de CA Adem s la resistencia del cableado de interconexi n ser de 10 ohms como m ximo La fuente de energ a adecuada es de 120 voltios de CA monof sica suministrada por un circuito no conmutable que no est protegido por un interruptor accionado por corriente de p rdida a tierra Las alarmas contra humo no se deben usar con rejillas de pro tecci n para los detectores a menos que se haya evaluado la combinaci n rejilla de protecci n para la alarma y el detec tor y se encuentre adecuada para ese prop sito ADVERTENCIA La alarma no debe funcionar con energ a proveniente de un convertidor de onda cuadrada o de onda cuadrada modificada Estos tipos de convertidores a veces se usan para suministrar energ a a la estructura en instalaciones aisladas de la red como fuentes de energ a solar o e lica Estas fuentes de energ a producen voltajes de
70. rodantes antiguas que no est n bien aisladas el calor y el fr o extremos se pueden filtrar desde el exterior al interior a trav s de paredes y un techo inade cuadamente aislados Esto puede formar una barrera t rmica que puede evitar que el humo llegue a una alarma montada en el cielo raso En ese tipo de casas rodantes instale la alarma contra humo mon xido de carbono en una pared interna con el extremo superior de la alarma a un m nimo de 4 pulgadas 10 cm y un m ximo de 12 pulgadas 30 5 cm bajo el cielo raso consulte la Figura 2 Si no est seguro de cu l es el aislamiento de su casa m vil o si observa que las paredes externas y el cielo raso est n calientes o fr os S LO instale la alarma en una pared interna Instrucciones de instalaci n ESTE EQUIPO SE DEBE INSTALAR DE ACUERDO CON LA NORMA 72 DE LA ASOCIACION NACIONAL DE PROTECCION CONTRA INCENDIOS National Fire Protection Association Batterymarch Park Quincy MA 02269 B D nde no instalar iNo instale la alarma en garajes cocinas calderas ni ba os INST LELA A UNA DISTANCIA M NIMA DE 5 PIES DE CUALQUIER APARATO QUEMADOR DE COMBUSTIBLE ADVERTENCIA Este producto est dise ado para su uso en habita ciones interiores comunes de vivien das familiares No esta dise ado para medir el cumplimiento con las normas comerciales e industriales de la Administraci n de Seguridad Salud Ocupacional OSHA No la instale a menos de 3 pies 0
71. section on pages 4 7 for a detailed description of each alarm pattern What To Do If The Alarm Sounds When the smoke alarm sounds Smoke alarms are designed to minimize false alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cook ing may set off the alarm if located too close to the cooking area Large quantities of combustible particles are generated from spills or when broiling Using the fan on a range hood which vents to the outside non recirculating type will also help remove these combustible products from the kitchen 18 What To Do If The Alarm Sounds If the alarm sounds check for fires first If a fire is discovered follow these steps Become thoroughly familiar with these items and review with all family members Alert small children in the home Leave immediately using one of your planned escape routes see page 26 Every second counts don t stop to get dressed or pick up valuables Before opening inside doors look for smoke seeping in around the edges and feel with the back of your hand If the door is hot use your second exit If you feel it s safe open the door very slowly and be prepared to close immediately if smoke and heat rush in If the escape route requires you to go through smoke crawl low under the smoke where the air is clearer Go to your predetermined meeting place When two people have arrived one
72. should leave to call 911 from a neighbor s home and the other should stay to perform a head count Do not reenter under any circumstance until fire offi cials give the go ahead There are situations where a smoke alarm may not be effec tive to protect against fire as stated in the NFPA Standard 72 For instance a smoking in bed b leaving children unsupervised c cleaning with flammable liquids such as gasoline 19 What To Do If The Alarm Sounds When the carbon monoxide alarm sounds WARNING Actuation of your CO Alarm indicates the presence of Carbon Monoxide CO which can kill you If alarm signal sounds 1 Operate the test reset button 2 Call your emergency PHONE NUMBER services Fire Dept or 911 3 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not reenter the premises nor move away from the open door window until the emergency services responders have arrived the premises has been aired out and your alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period repeat steps 1 3 and call a qualified appliance PHONE NUM BER technician to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified during this inspection have the equipment serviced immediately
73. sing the test reset button A series of beeps will sound followed by the message Fire Fire then another two series of beeps and the message WARNING CARBON MONOXIDE followed by 4 additional short beeps Weekly testing is required If at anytime it does not perform as described verify power is connected correctly and that the bat tery doesn t need replacing Clean dust and other buildup off the unit If it still doesn t operate properly call the Consumer Hotline at 1 800 880 6788 14 Operating Instructions Interconnect Feature Your Combination Smoke CO Alarm is interconnectable to other multiple station Kidde Nighthawk and Kidde Fyrnetics products When compatible smoke alarms and heat alarms are inter connected to your Smoke CO Alarm they will only respond to a smoke related event e When mixing compatible models with battery backup with models without battery backup be advised that the models without battery backup will not respond during an AC power failure This unit is only approved to interconnect with other Kidde Nighthawk products It is NOT approved to intercon nect with any other brand of detection product This alarm is interconnect compatible with the following alarms and accessories Smoke alarms 1235 1275 1276 1285 1296 112020 112040 112060 112080 PE120 PI2000 KN COSM IB KN COSM I and RF SM ACDC Heat alarm 135 CO alarms KN COB IC KN COP IC Rela
74. t up 12 Installation Instructions Step 3 Mounting Instructions CAUTION YOUR SMOKE CO ALARM IS SEALED AND THE COVER IS NOT REMOVABLE 1 To help identify the date to replace the unit a label has been N affixed to the side of the alarm Write the Replace by date 7 years from initial power up in permanent marker on the label See Alarm Replacement section for additional information Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the OFF arrow on the alarm cover 3 After selecting the proper location for your Smoke CO Alarm as described on Pages 8 10 and wiring the QUICK CON NECT harness as described in the WIRING INSTRUCTIONS attach the mounting bracket to the electrical box To ensure aesthetic alignment of the alarm with the hallway or wall the A line on the mounting bracket must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Pullthe AC QUICK CONNECTOR 2 through the center hole in the 224 mounting bracket secure y AR the bracket making sure that m the mounting screws are posi gs tioned in the small ends of the keyholes before tightening the screws di gt Plug the AC QUICK CONNEC FIGURE 4 Installing AC TOR into the back of the alarm Quick Connect see figure 4 making sure that the locks on th
75. unca trate de desmontar la unidad o de limpiarla por dentro Esta acci n dejar sin efecto su garant a 24 Informaci n de seguridad sobre el mon xido de carbono Mueva la alarma contra humo mon xido de carbono y ub quela en otro lugar antes de realizar cualquiera de las siguientes actividades te ir o desforrar muebles o pisos de madera pintar empapelar muros usar adhesivos Si se guarda la unidad en una bolsa pl stica durante las actividades antes mencionadas se proteger n los sensores contra da os No la coloque cerca de un cubo de pa ales ADVERTENCIA Vuelva a instalar la alarma contra humo mon xido de carbono lo antes posible para asegurar una protecci n continua Cuando use art culos para la limpieza del hogar o contaminantes similares el rea debe estar bien ventila da Las siguientes sustancias pueden afectar el sensor de mon xido de carbono y pueden producir lecturas falsas o da o al sensor metano propano isobutano isopropanol acetato etilico sul furo de hidr geno di xidos de azufre productos en base a alcohol pinturas diluyente solventes adhesivos aerosoles para el pelo productos para despu s de afeitarse perfumes y ciertos productos de limpieza Informaci n de seguridad sobre el mon xido de carbono Informaci n general sobre el mon xido de carbono El mon xido de carbono CO es un gas venenoso incoloro inodoro e ins pido que puede ser fatal si se inhala El mo
76. y modules 120X SM120X CO120X Strobe Light SL177i See User s Guides for specific application information For more information about compatible interconnect units and their functionality in an interconnect system visit our web site at www kidde com HUSH Control Feature The HUSH feature has the capability of temporarily desensitizing the smoke alarm circuit for approximately 10 minutes This fea ture is to be used only when a known alarm condition such as smoke from cooking activates the alarm You can put your Smoke CO Alarm in HUSH mode by pushing the test reset but ton If the smoke is not too dense the alarm will silence imme 15 Operating Instructions diately the unit will verbally announce HUSH MODE ACTIVAT ED and the green LED will flash every 2 seconds for approxi mately 10 minutes This indicates that the smoke alarm is in a temporarily desensitized condition Your Smoke CO Alarm will automatically reset after approximately 10 minutes When the unit returns to normal operation after being in HUSH mode it will verbally announce HUSH MODE CANCELLED and sound the alarm if smoke is still present The HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm While the unit is in HUSH mode pushing the test reset button on the alarm will also end the HUSH period NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CON TROL FEATURE AND SOUND A CONTINUOUS ALARM CAUT