1. NOTE Codes in the state of Massachusetts require installation by a licensed plumber If you live in the state of Massachusetts review plumb ing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installation B WATER SUPPLY TYPICAL CONNECTION USING COMPRESSION TYPE FITTING PARTS NOT INCLUDED NOTE Before starting be sure to turn off water supply and open a low faucet to drain the pipe Complying with plumbing codes install a fitting on the cold water pipe to adapt to 3 8 O D tubing A typical connection is shown in Figure 4 If threaded fittings are used be sure to use pipe joint compound or Teflon tape on outside threads cold water shutoff valve CO 3 8 compression fitting insert r4 ferrule cold water _ gt pipe 3 8 yellow tubing to Water Filter inlet Figure 4 Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Step 2 Install Filtered Water Faucet MAKE HOLE FOR FAUCET IMPORTANT A 1 1 4 dia hole is needed to mount the filtered water faucet To avoid damaging the sink con sult a qualified plumber or installer for drilling proce dures in porcelain or stainless steel 1 Select one of the following options to install the faucet Make sure there is room underneath to make the need ed connections e Use an existing sink top hole for spray hose or soap dispenser must be 1 1 4 in diameter Drill a new hole in t
2. 1 How much water you use and 2 How much sediment taste and or odor or other unwanted substances are in the water Use the following information as a guide However no matter which type of cartridge you are using you will know it is time to replace it when you first notice the return of unwanted substances in your water Kenmore Elite Advanced Two Stage Drinking Water Filter model 625 385010 with replacement element pack 42 34381 conforms to NSF ANSI 42 and 53 for the specif ic performance claims as verified and substantiated by test data The rated capacity for this system is 280 gal lons 1060 liters at a rated service flow of 0 5 gpm gal lons per minute battery housing battery negative side facing C Ff the front screw faucet 7 base Figure 14 Turn to the left to remove A Filter Cartridge 1 Filter Cartridge 2 Figure 15 FILTER CARTRIDGE REPLACEMENT Complete the following steps to replace the cartridges 1 Turn filter cartridge to the left to remove cartridges from the filter heads See Figure 15 2 Dispose of the old cartridges in a proper manner 3 Install new cartridges making sure to insert cartridge 1 and 2 into the correct opening note the printing on the cover designating Cartridge 1 and Cartridge 2 Turn cartridges to the right to re attach to the fil ter heads 4 Remove and replace the timer batte
3. OWNER S MANUAL Advanced Two Stage Drinking Water Filter MODEL NO 625 385010 Caution Read and follow all safety rules and operating instructions before first use of this product Questions Visit www KenmoreWater com or Call toll free 1 800 426 9345 M F 7 AM 8 PM CST Repair or Parts Call toll free 1 800 469 4663 See back cover for other Sears service numbers SAVE THIS MANUAL e Warranty e Installation e How It Works e Care Of e Specifications e Repair Parts VERD e ENSF i T i A AN Ra No System Tested and Certified by NSF International against NSF ANSI Standard 42 and 53 See performance data sheet for details Sears Roebuck and Co 3333 Beverly Road Hoffman Estates IL 60179 U S A PRINTED IN U S A www KenmoreWater com Part No 7294294 Rev D 6 12 07 ONE YEAR FULL WARRANTY ON THE KENMORE ELITE ADVANCED TWO STAGE DRINKING WATER FILTER When installed operated and maintained according to all instructions supplied with the product if this Two Stage Drinking Water Filter fails due to a defect in material or workmanship within one year from the date of purchase call 1 800 4 MY HOME to arrange for free repair or replacement if repair proves impossible This warranty does not include filter cartridges which are expendable items This warranty applies only while this product is in use in the United States or Canada This warranty gives you specific legal rights and you
4. he faucet to the base 3 Install battery in faucet base See Change Battery sec tion on Page 9 then continue installation with Step 3 on Page 8 faucet base 1 1 4 dia hole through sink or countertop rubber gasket toggle bolts Figure 5 Q faucet faucet base i i Ag ANg SS blue tubing pe filter Figure 6 faucet 1 4 turn to connect faucet to base faucet base Figure 7 Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Step 3 Connect Tubes CONNECT YELLOW TUBE TO WATER SUPPLY FITTING I Locate the yellow tube One end is attached to the fil ter housing Run the other end to the water supply fit ting on the cold water pipe See Figure 8 Refer to the Cut Tubes to Length section below and cut the yellow tube square and to length as needed Refer to the Connect Tubes section below and insert the yellow tube all the way into the 3 8 quick connect fitting on included water supply fitting installed in Step 1 Pull on the tube to be sure it is held firmly in the fit ting HOW TO CUT AND CONNECT THE TUBES Your Advanced Two Stage Drinking Water Filter includes push in fittings for quick tubing connection Review the following before connecting the tubes Cut tubes to length 1 Use a sharp cutter or knife to cut the end of tubing Always c
5. he sink top Drill a hole in the countertop next to the sink 2 Check to make sure the filtered water faucet base will sit flat against the mounting surface 3 If drilling is needed make a 1 1 4 dia minimum hole for the faucet in the mounting surface INSTALL FAUCET BASE 1 Locate the faucet base See Fig 5 and feed the toggle bolts down through the hole until the faucet base is square against the mounting surface sink or counter top The rubber gasket should be between the faucet base and mounting surface 2 Tighten the toggle bolts until the faucet base is firmly mounted to the surface Do not overtighten CONNECT BLUE TUBE TO FAUCET 1 Place the Advanced Two Stage Drinking Water Filter housing under the sink It can sit upright or on its side 2 Locate the blue tube One end is attached to the filter housing Feed the other end up through the mounting hole and faucet base See Figure 6 Q Refer to the Cut Tubes to Length section on Page 8 and cut the blue tube square and to length as needed leaving about 6 inches above the faucet base 4 Locate the faucet Refer to the Connect Tubes section on Page 8 and insert the blue tube all the way into the 3 8 quick connect fitting on the faucet bottom 5 Pull on the tube to be sure it is held firmly in the fit ting INSTALL FAUCET ON BASE 1 Lower the faucet onto the base See Figure 7 2 Give the faucet a 1 4 turn clockwise to attach t
6. home or ours Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 14 800 469 4663 Call anytime day or night U S A and Canada www sears com WwWwW Sears Ca For expert home solutions advice www managemyhome com Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts amp Repair Service Center 1 800 488 1222 U S A 1 800 469 4663 Canada Call anytime day or night www sears com www sears Cca To purchase a protection agreement on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacion Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER lt 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 www sears ca Sears Calls Registered Trademark Trademark Service Mark of Sears Brands LLC Marca Registrada Marca de Fabrica Marca de Servicio de Sears Brands LLC MC Marque de commerce MP Marque de d pos e de Sears Brands LLC Sears Brands LLC
7. ilter works on water pressures of 30 psi minimum to 125 psi maximum If your house water pressure is over the maximum install a pressure reducing valve in the water supply pipe to the Advanced Two Stage Drinking Water Filter Y Do not install the Advanced Two Stage Drinking Water Filter outside or in extreme hot or cold temper atures Temperature of the water supply to the Advanced Two Stage Drinking Water Filter must be between 40 F and 100 F Do not install on hot water Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Unpack and Check Your Carton INSPECT SHIPMENT Your Advanced Two Stage Drinking Water Filter is shipped complete in one carton Remove all items from your shipping carton Check all items against the packing list below Note any items lost or damaged in shipment Note any damage to the shipping carton Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items If problems exist refer to the website or the toll free number listed throughout this manual Keep the small parts in the parts bag until you are ready to install them NOTE Codes in the state of Massachusetts require installation by a licensed plumber If you live in the state of Massachusetts review plumb ing code 248 CMR of the Commonwealth of Massachusetts before proceeding with the installation Packing List Bag Assembly Bag Asse
8. led incorrectly Correction Install battery correctly Problem Water leaks at push connect fittings Cause Tubing not pushed in all the way Correction Push Tubing all the way into fittings See Page 8 Cause Tubing not cut square Correction Cut tubing square See Page 8 Remove tube from connection Remove nicked portion Cause Tubing nicked Correction by cutting tube to shorter length Reinsert in connection See Page 8 Remove tube from connection Remove problem area Cause Outer tubing surface not smooth Correction by cutting tube to shorter length Reinsert in connection See Page 8 Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Repair Parts Manifold Housing PUSH IN FITTINGS collet D YD o ring seal 1292674 Faucet with base amp electronics 7294359 Cover Half marked Cartridge 1 amp Cartridge 2 7293175 Cover Half unmarked order decal below Decal Kenmore Elite badge Screw Cover 4 req Head Assembly Tubing 3 8 O D x 72 long Yellow Tubing 3 8 O D x 72 long Blue Pee Owner s Manual Purchase replacement filter cartridges at your local Sears store online at www sears com or from Sears Parts at 1 800 469 4663 O ring and collet kit for replacement in the manifold housing only Not included WE Not illustrated Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com 11 Get it fixed at your
9. may have other rights which vary from state to state Sears Roebuck and Co Hoffman Estates IL 60179 Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Unpack and Check Shipment Plan Your Installation Step 1 Install Supply Water Fitting Step 2 Install Filtered Water Faucet Step 3 Connect Tubes Maintenance Specifications Troubleshooting Exploded View amp Parts List Table of Contents safety Guides YV Read all steps and guides carefully before installing and using your Advanced Two Stage Drinking Water Filter Follow all steps exactly to correctly install Reading this manual will also help you to get all the benefits from the Advanced Two Stage Drinking Water Filter Y Do not attempt to use this product to make safe drinking water from non potable water sources Do not use the system on microbiologically unsafe water or water of unknown quality without adequate disin fection before or after the system This system is certi fied for cyst reduction and may be used on disinfec ted water that may contain filterable cysts V Check with your local public works department for plumbing and sanitation codes You must follow their guides as you install the system Follow your local codes if they differ with guides in this manual In Massachusetts plumbing code 248 CMR 3 00 and 10 00 shall be adhered to Consult with a licensed plumber V The Advanced Two Stage Drinking Water F
10. mbly Tee Feed Adaptor E Thread Sealing Tape Coin Battery Advanced Two Stage Drinking Water Filter Faucet amp Electronics Base Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Plan Your Installation PLAN YOUR INSTALLATION It is recommended to read through the entire manual Tools Needed before beginning your installation Follow all steps exactly Reading this manual will also help you get all the benefits from your system TYPICAL UNDER SINK LOCATION The Advanced Two Stage Drinking Water Filter housing eane is normally located under the kitchen and or bathroom Adjustable Wrench sink to filter the cold drinking water See Figure 2 CHECK SPACE REQUIREMENTS Check size and position of items for proper installation into location chosen TOOLS NEEDED Review the tools needed list See Figure 1 Gather need ed tools before proceeding with the installation Read and follow the instructions provided with any tools list ed here IMPORTANT A 1 1 4 dia hole is needed to mount the filtered water faucet To avoid damaging the sink con Large Adjustable Jaw Pliers or Pipe Wrench sult a qualified plumber or installer for drilling proce dures in porcelain or stainless steel Figure 1 Typical Under Sink Installation filtered water i faucet blue tubing J WATER OUT cold water supply fitting yellow tubing WATER IN E Fig
11. re 11 Figure 12 Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Maintenance FAUCET ELECTRONICS Inside the faucet base is a battery operated 6 month timer See Figure 14 An amber LED indicator is also located in the front of the faucet base This LED will flash continuously after 6 months has passed This indicates that it is time to replace the battery and filter catridges CHANGE BATTERY To change or install the battery complete the following steps 1 Loosen the screw on the right side of the faucet base See Figure 14 2 Press the battery housing upwards from the front faucet base until it releases from the faucet base See Figure 14 Replace or install the battery Maxell CR 2032 or equivalent Place battery into the holder with the positive side facing the back of the holder QU 4 When the battery is first replaced it will flash six times and turn off This indicates the battery is fully charged After the six flashes the timer enters the 6 month time cycle NOTE If the LED repeatedly flashes just two times it is not a fully charged battery and will need to be replaced 5 Re install the timer housing and firmly tighten the mounting screw See Figure 14 FILTER CARTRIDGE LIFE It is recommended to replace the battery and filter car tridges every 6 months of use There are several vari ables that determine how long a cartridge will last These include
12. ry See Change Battery above Taste and Odor Cartridges Filter cartridges contain acti vated carbon a black powder When new open the fil tered water faucet and allow fine carbon particles to purge from the cartridge Close the faucet when you no longer see the fines carbon particulates in the filtered water or approximately 10 minutes Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com 10 Specifications DUD Diy Water pressure MINS sonc46 5canontach ikiii puii i ie ois 30 125 psi 207 862 kPa pp Water temperate U E a a E A Ceo T E 40 100 F 5 40 C eai S E EE EEE E EE T os bee woe et ousea es 3 8 O D tubing included This system conforms to NSF ANSI 42 and 53 for the specific performance claims as verified and substantiated by test data Installations In The Commonwealth Of Massachusetts The Commonwealth of Massachusetts requires instal lation be performed by a licensed plumber Plumbing code 248 CMR of the Commonwealth of Massachusetts must be followed in these cases Troubleshooting Problem Taste and or Odor Cause Pre amp Post filter expended Correction Replace the filter cartridges See Page 9 Cause System contaminated Correction Sanitize system Call 1 800 426 9345 for instructions Problem Faucet LED indicator light does not function after battery change Cause Battery dead Correction Replace with new battery See Page 9 Cause Battery instal
13. ure 2 Filter Housing may be placed horizontally OR vertically Questions Call The Kenmore Water Line 1 800 426 9345 or visit KenmoreWater com Step 1 Install Water Supply Fitting CHOOSE TYPE OF WATER SUPPLY FITTING TO INSTALL Locate the cold water line in the sink cabinet Check and comply with local plumbing codes as you plan and then install a water supply fitting on the sink s cold water line The fitting must provide a leak tight connection to the Advanced Two Stage Drinking Water Filter s 3 8 O D inlet tubing A typical connection using the included water supply fitting is shown in Fig 3 An alternative connection using standard plumbing fittings not includ ed is shown in Fig 4 A WATER SUPPLY CONNECTION USING INCLUDED FITTING Close the house main water shutoff valve and open faucets to drain water from the sink s cold water pipe EEN 2 Remove the nut that connects the cold water faucet to cold water plumbing U Thread the included water supply fitting onto the pipe and reconnect nut to bottom of fitting included water faucet stud gt supply fitting cold water 3 8 O D yellow tubing to Water Filter inlet wrap outside threads with a Teflon tape cold water _ gt SK cold water shutoff valve Figure 3 OR NOTE Local code may dictate which type of water fit ting is used Consult a plumber if you are not familiar with local codes or plumbing procedures
14. ut the tubing square See Figure 9 2 Inspect the end about 1 of the tubing to be sure there are no nicks scratches or other rough spots If needed cut the tubing again Connect tubes i Push tubing through collet until it engages the o ring See Figure 10 Continue pushing until the tube bot toms out against the back of the fitting See Figure 11 A common mistake is to stop pushing when the tube engages the o ring This will lead to future leaks When a 3 8 tube is fully engaged 3 4 of the tube has entered the fitting See Figures 10 amp 11 If using tubing other than tubing supplied with the system be sure it is of high quality exact size and roundness with a smooth surface Disconnect Tubes 1 Push the collet inward with a finger tip See Figure 12 2 Continue holding collet inward while pulling the tub ing out See Figure 13 O Ring Seal Collet 7 Op vane Collet and O Ring Figure 13 cold water supply fitting an CO cold water filter _ gt shutoff housing Push In Fitting Tube Cut tubing square with end of tubing round smooth with no cuts nicks or flat spots Tube Correctly Cut O Ring at GS ZAA N A Peroz CHIE Tube Fully Engaged With Fitting Collet Depress to Remove Tubing a ee Tubing Disconnect Tubing Figure 8 Figure 9 Figure 10 Figu

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書 - イメージニクス  Online UPS PowerWalker VFI 6000CRM LCD Manual  P40-08-Manuel_WD9541_IT_R050608_final MF_ss alm tempête  electric cream separator fj – 600 ll user´s manual  Riquemaq  PROFESIONAL 2015 BAJA    Distributore e Centro di Assistenza Ferno Washington Italia S.r.l.  MTH-1362 / MTH-1362W TERMO HIGRÔMETRO DIGITAL  Manual do usuário  