Home

Kenmore 153.31702 Water Heater User Manual

image

Contents

1. HQ 21 Parts Order List 22 23 24 Customer Responsibilities Thank You purchasing a Sears water heater Properly installed and maintained it should give you years of trouble free service If you should decide that you want the new water heater professionally installed by Sears call the local Service Center or any Sears store They will arrange for prompt quality installation by Sears authorized contractors Abbreviations Found In This Instruction Manual U L Underwriters Laboratories Inc 333 Pfingsten Rd Northbrook IL 60062 NEC National Electrical Code ANSI American National Standards Institute Read the Safety Precautions section page 2 of this manual first and then the entire manual carefully If you don t follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation opera tion and maintenance of this electric water heater It also con tains warnings throughout the manual that you must read and be aware of All warnings and all instructions are essential to the proper operation of the water heater and your safety Since we cannot put everything on the first few pages READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER Product Specificati
2. POINT OF USE ELECTRIC WATER HEATER Safety Instructions Care and Maintenance Installation Troubleshooting Operation Parts List RATING GAMA certification applies to all residential electric water heaters with NA capacities of 20 to 120 Gallons Input rating of 12 Kw or less at a voltage ama no greater than 250 V READ THE GENERAL SAFETY SECTION BEGINNING INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERAT ING THIS WATER HEATER Sears Roebuck and Co Hoffman Estates IL 60179 U S A Printed in the U S A 1203 www sears com Part No 184734 000 Safety Precautions A WARNING Improper installation adjustment alteration service or maintenance can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Refer to this manual for assistance or consult your local Sears Service Center for further information A WARNING At the time of manufacture this water heater was provided with a combination temperature pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems and the current edition of ANSI 221 22 CSA 4 4 and the code requirements of ASME If replaced the valve must meet the requirements of local
3. 7 2 LLJ LI TEMPERATURE PRESSURE RELIEF VALVE KC CG DISCHARGE PIPE not cap plug Provide a 6 air gap between pipe and drain K WARNING RELIEF VALVE OPENING This water heater is provided with a combination omoro Treca Relief Valve listed as complying with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems Al 1 22 and the code requirements of ASME Your focal jurisdictional authority while mandating the use of a Temperature Pressure Relief Valve complying with ANS 221 22 and ASME may require a valve model different from the one furnished with the water heater Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed Temperature Pressure Relief Vaive installed in the designated opening in the water heater RELIEF VALVE PROBE n MUST EXTEND INTO TANK LENGTH if a short shank 1955 than 2 temperature pressure relief valve is to be installed as shown a nipple and coupling must be used if a long shank 2 or longer is fo be installed do not use the nipple and coupling Install Temperature Pressure protective equipment required by local codes but not less than a combina tion Temperature Pressure Relief Valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Su
4. Check all new water piping for leaks Repair as needed Optional Cord Set Wiring 120 Volt There may be a cord set supplied with the water heater at the time of manufacture If not one can be ordered through the Parts Department see Repair Parts section Refer to figures on this page for wiring diagrams Wiring Diagrams 120 VOLT CORD SET GREEN z GROUND THERMOSTAT WHITE ELEMENT 120 VOLT WIRING GREEN GROUND THERMOSTAT BLACK ELEMENT 10 Installation Instructions Wiring CAUTION Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON You must provide all wiring of the proper size outside of the water heater You must obey local codes and electric company requirements when you install this wiring If you are not familiar with electric codes and practices or if you have any doubt even the slightest doubt in your ability to con nect the wiring to this water heater obtain the service of a com petent electrician Contact your Sears salesperson to arrange for a professional electrician A WARNING WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY This water heater is equipped for one type volt age only Check the rating plate near the bottom acces
5. Kenmore Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING Model No 153 317020 2 Gal LISTED Caution Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product Save this Manual for Future Reference
6. This odor is derived from hydrogen sulfide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop a a concentration of sulfate in the supply water b little or no dissolved oxygen in the water a sulfate reducing bacteria within the water heater This harmless bacteria is non toxic to humans d an excess of active hydrogen in the tank This is caused by the corrosion protective action of the anode The anode rod in a new glasslined water heater works rapidly to protect the tank After a period of time the anode action slows and the odor may dissipate A smelly water condition Rotten Egg Odor in your Point of Use water heater can in most cases be resolved or reduced with the addition of sufficient amounts of chlorine to eliminate the bacterial growth inside the tank This can be accomplished through the installation of a chlorine feeder to the system or the flushing of water heater with Chlorox as needed On systems where the odor is mild and does not occur too rapidly a monthly flushing may be sufficient In more severe cases a system feeder cou be more appropriate AIR IN HOT WATER FAUCETS A WARNING HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possi bility of injury under t
7. instruc tions in the Service and Adjustment section and then remove fitting Put pipe dope or teflon tape on the threads and replace Then follow Filling the Water Heater instructions the Installation Instructions section 21 Parts Order List KENMORE POINT OF USE ELECTRIC WATER HEATER MODEL NUMBER 153 317020 2 Gal 22 Parts Order List cont d KENMORE POINT OF USE ELECTRIC WATER HEATER MODEL NUMBER 153 317020 2 Gal MODEL NUMBERS KEY PART 153 317020 NO DESCRIPTION PART NUMBERS 1 Temperature Pressure Relief Valve 9000071 2 Dip Tube amp Gasket 9002396 3 Drain Valve 9002402 Drain Valve Washer 7 x x 4 thick 9001584 5 Element Gasket 9000508 6 Element 9001511 7 Thermostat Bracket 9000509 8 Thermostat w Hi Limit 9002394 9 Terminal Cover 9002438 10 Access Panel 9001472 11 Wiring Bushing 9001514 12 Cord Set 120 Volt 9001513 13 Mounting Brackets 9001512 14 Junction Box Cover 9001474 15 Model Rating Platet 0270182 Manual 184734 000 Also available at most hardware stores TReplaced only on return of damaged plate Not lHlustrated Now that you have purchased your Water Heater should a need ever exist for repair parts or service simply contact any SEARS Service Center or call 1 800 4 MY HOME 1 800 469 4663 Be sure to provide all pertinent facts
8. ADJUSTABLE THERMOSTAT Temperature Settings The thermostat is factory set at a position which approximates 120 F Hot and is adjustable if a different water temperature is desired Read all warnings in this manual and on the water heater before proceeding LO Setting approximately 95 F is recommended for vaca tions or extended periods of no hot water Is a setting for the maximum hot water usage approxi mately 140 which can be supplied by the water heater The temperature dial should be kept at a lower setting whenever possible NOTE Water temperature range of 120 140 F recom mended by most dishwasher manufacturers Time to Produce 2nd amp 3rd Degree Burns on Adult Skin Temperature Setting 160 F About 1 2 seconds 50 F About 1 42 seconds 40 F Less than 5 seconds 30 F About 30 seconds 20 F More than 5 minutes Thermostat Adjustment The thermostat is adjustable if a different water temperature is desired Read all warnings in the Temperature Regulation sec tion before proceeding To adjust the temperature setting 1 Turn OFF the electrical power to the water heater at the junction box A WARNING HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Failure to do this could result in DEATH SERIOUS BODILY INJURY OR PRO
9. HACKSAW 6 FOOT TAPE GARDEN HOSE 3 4 WIRE BRUSH SLOT HEAD SCREWDRIVER P WRENCH 1 2 WIRE BRUSH PHILLIPS SCREWDRIVER NEN ROLL OF LEAD FREE PROPANE TORCH SOFT SOLDER PIPE DOPE SQUEEZE TUBE ue p roll of teflon tape ROLL OF EMERY SOLDER TUBING Use only on water connections CLOTH FLUX CUTTER Installation Instructions Removing the Old Water Heater O Turn OFF electrical supply to the water heater 11 Faa ja F Turn OFF the water supply to the water heater at the water shutoff valve or water meter m s s Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors Open the water heater drain valve Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining A WARNING The water passing out of the drain valve may be extreme ly hot To avoid being scalded make sure all connections are tight and that the water flow is directed away from any person 4 Check again to make sure the electrical supply is turned OFF to the water heater Then unplug the water heater cord set or disconnect the electrical sup ply connection from the water heater junction box TO SERVICE PANEL 4 WIRE NUT CONNECTIONS ACCESS OPENING HEATER WIRING SE T Os 52 If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw
10. Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning power 14 Check element for water leaks If leakage occurs tighten element or repeat steps 2 and 3 remove element and reposi tion gasket Then repeat steps 10 through 14 15 Reconnect the two wires to the element and then check to make sure the thermostat remains firmly against the surface of the tank 16 Replace terminal cover on thermostat and fold insulation back over the element BEFORE SERVICING REMOVE PULL ARROW OF COVER Service and Adjustment 17 Fold the insulation back in place so that it completely covers the thermostat and element 18 Replace access panel 19 electric power to water heater 8 cr i Kem TW nnt c DC Yi 1701692 16731 CAUTION Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning ON power 17 Drain Valve Washer Replacement NOTE For replacement use a 2 x x A thick washer available at your nearest hardware store For ordering a replacement washer refer to the Parts Order List section B
11. Failure to use the correct voltage can cause problems which can result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE If you have any ques tions or doubts consult your electric company A WARNING INSULATING JACKETS When installing an external water heater insulation jacket on an electric water heater DO NOT cover the temperature pressure relief valve b DO NOT put insulation over the access covers or any access areas c DO NOT remove operating instructions and safety related warning labels and materials affixed to the water heater d DO obtain new warning and instruction labels from Sears for placement on the jacket directly over the existing labels WARNING Do not use this appliance if any part of it has been under water An electrical short or malfunction could occur The water heater should be replaced A CAUTION WATER HEATERS EVENTUALLY LEAK Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak the flow of water will not cause damage to the structure When such locations cannot be avoided a suitable drain pan should be installed under the water heater Drain pans are avail able at your local Sears Store Such a drain pan must be piped to an adequate drain Table of Contents PECADO MSs eed Tab ISOLE ais nastro samet E A ene beaten PROCITE S Mater
12. If you had experienced very hot water and now no hot water the problem may be due to the high temperature shut off system See High Temperature Shut Off System in the Troubleshooting section During very cold weather the incoming water will also be colder and it will require a longer time to become heated The hot water usage may exceed the capacity of the water heater If so wait for water heater to recover after abnormal demand Also examine pipes and faucets for possible water leaks If you can not determine the problem then call the Sears Service Department WATER 15 TOO HOT Adjust the thermostat to a lower setting See the Temperature Regulation section Troubleshooting guide cont d Leakage Checkpoints Use this guide to check a Leaking water heater Many suspected Leakers are not leaking tanks Often the source of the water can be found and corrected A CAUTION Read this manual first Then before checking the water heater make sure the electric supply has been turned OFF and never turn the electric supply ON before the tank is completely full of water If you are not thoroughly familiar with electric codes the water heater and safety practices contact a Sears Service Center to check the water heater Condensation may be seen on pipes in humid weather or pipe connections may be leaking Small amounts of water from the temperature pressure relief valve
13. any dis charge will exit only within 6 inches above or at any distance below the structural floor Be certain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 air gap is provided To prevent bodily injury haz ard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage The Discharge Pipe Must not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Must not be plugged or blocked Must be of material listed for hot water distribution Must be installed so as to allow complete drainage of both the temperature pressure relief valve and the dis charge pipe Must terminate at an adequate drain Must not have any valve between the relief valve and tank A WARNING HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Fail
14. may be due to thermal expansion or high water pressure in your area The temperature pressure relief valve may be leaking at the tank fitting The element may be leaking at the tank fitting A WARNING HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned Failure to do this could result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Turn electrical power OFF remove access panel and fold back insulation If leaking around element follow proper draining instructions and remove element Reposition or replace gasket on element Place element into opening and tighten securely Then follow Filling the Water Hester instructions in the Installation Instructions section Water from drain valve may be due to the valve being opened slightly The drain valve may be leaking at the tank fitting 0O Water in the water heater bottom on the floor may be from condensation loose connections or the temper ature pressure relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seepage should also be checked NOTE To check where threaded portion enters tank insert cotton swab between jacket opening and fitting If cotton is wet follow Draining
15. tape around the threaded end of the compression coupling and around the 2 threads of the x 4 reducer bushing Put two or three turns of teflon tape around both ends of a 4 threaded nipple not sup plied in the installation kit Attach the nee d nipple to Hie X x A reducer bushing and screw into the hot water outlet of the water heater Using flexible connectors connect the hot water pipe to the hot water outlet of the water heater NOTE If using copper tubing solder tubing to an adapter before attaching the adapter to the water connec tions Do not solder the water supply lines directly to the connections of the water heater It will harm the fittings on the water heater Look at the top of the water heater The cold water inlet is marked cold Put two or three turns of teflon tape around the threaded end of the compression coupling and around the 2 threads of the 4 x 4 reducer bushing Put two or three turns of teflon tape around both ends of a 4 threaded nipple not sup plied in the installation kit Attach the 7 me d nipple to the A x 4 reducer bushing and screw into the cold water inlet of the water heater Using flexible connectors connect the hot water pipe to the hot water outlet of the water heater NOTE Your water heater is insulated to minimize heat loss from the tank Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater Installation COMPLETE
16. than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that sat isfies your hot water needs some type of tempering device such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturers instructions for installation of the valves Before changing the factory setting of the thermostat read the Temperature Regulation section in this manual A WARNING Never allow small children to use a hot water tap or to draw their own bath water Never leave a child or handicapped person unattended in a bath tub or shower Thermostats This special thermostat with ECO Part No 9002394 can only be used with this water heater Do not use any other thermostat with ECO The thermostat of this water heater has been factory set at the mid position which approximates 120 F Hot to reduce the risk of scald injury The thermostat is adjustable if a different water temperature is desired Read all warnings in this manual and on the water heater before proceeding APPROXIMATE TEMPERATURES
17. the Product Specifications sec tion Is the new temperature pressure relief valve properly installed and piped to an adequate drain See Temperature Pressure Relief Valve section Is the water heater completely filled with water See Filling the Water Heater instructions in the Installation Instructions section 4 Will a water leak damage anything See Facts to Consider About the Location section Are the cold and hot water lines connected to the water heater correctly See Water Piping instructions in the Installation Instructions section Is there adequate clearance for maintenance around the water heater Do you need to call your electric company to check your wiring 12 SHUT OFF TEMPERATURE PRESSURE cay VALVE RELIEF VALVE gt d S Big S81 1 2 6 HOT WATER COLD WATER le E 27 4 CONDUIT QE 59 A d D DISCHARGE PIPE Do not cap or plug Provide a 6 air gap between the end of the pipe and drain SEE CONVERSION MODEL RATING PLATE Service and Adjustment Temperature Regulation HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing and other sanitizing needs can scald and manently injure you upon contact Some people are more likely to be permanently injured by hot water
18. when you call or visit All parts listed may be ordered from any SEARS Service Center most SEARS stores and by calling 1 800 366 PART 1 800 366 7278 If the parts you need are not stocked locally your order will be electronically transmitted to a SEARS Repair Parts Distribution Center for handling model number of the water heater will be found on the model rating plate located beside the access panel WHEN ORDERING REPAIR PARTS ADWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER NAME OF ITEM PART NUMBER PART DESCRIPTION THIS IS A REPAIR PARTS LIST NOT A PACKING LIST 23 e e e e e e e e e e e e e e e e e e e e e e e e e e e e gt e gt gt gt eum 225 250 9 x KS lt gt lt Y 96 9 6S FULL 90 DAY WARRANTY ON WATER HEATER Ges oy 2229 2 RY For 90 days from the date of purchase when your Sears Kenmore water heater is installed and operated in a single family residence R 229 in accordance with the instructions in this manual Sears will ox 2 X R 6 OS 259 55 1 Repair defects material or workmanship in this water heater free of charge 6 eS 2 Furnish and install a new current model water heater of equal capacity and quality free of charge if a leak occurs in the tank 155 96 lt ORS 229 Dn R LIMITED WARRANTY ON TANKS THAT LEAK 2o OKO A AN 5 z 4 2 5 5 After 90 days and through 1 year from the dat
19. D using Installation Kit COMPRESSION SHUTOFF J COUPLING Ww CzVALVE So te ROT HOT OUTLET COLD INLET TO HOUSE WATER LINE FLEXIBLE WATER CONNECTORS gr U2 x3 4 REDUCER BUSHING 3 lt 12 THREADED NIPPLE not supplied installation kit H2 x3 4 REDUCER 8 BUSHING 1 2 THREADED e Av NIPPLE not supplied X with installation kit ee 652 DRAIN VALVE Installation Instructions Temperature Pressure Relief Valve WARNING At the time of manufacture this water heater was provided with a combination temperature pressures relief valve certi fied by a nationally recognized testing laboratory that main tains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems and the current edition of ANSI 221 27 CSA 4 4 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 CSA 4 4 by a nationally recognized testing laboratory that maintains periodic inspection of pro duction of listed equipment or materials The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure o
20. LS PER HOUR WATTAGE WIRE SIZE BREAKER NUMBER IN GALLONS DIAMETER HEIGHT 90 F RISE 120 Voit GAUGE SIZE AMPS 153 317020 2 10 12 7 1440 12 20 Wiring size based on standard 60 C copper wire If distance from fuse box to water heater is more than 90 feet refer to your local elec trical code Materials and Basic Tools Needed Materials Needed To simplify the installation Sears has available the installation parts shown below You may or may not need all of these materi als depending on your type of installation EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLON CAPACITY THROUGH LOCAL SEARS SERVICE CENTERS DRAIN PANS AVAILABLE IN 20 DIAMETER FOR WATER HEATERS HAVING DIAMETER 18 OR LESS 24 DIAMETER FOR WATER HEATERS HAVING A DIAMETER 22 OR LESS AND AVAILABLE IN 28 WATER HEATER INSTALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3 4 OR DIAMETER FOR WATER HEATERS buc re OR COPPER HAVING A DIAMETER 26 OR LESS ADDITIONAL TOOLS NEEDED WHEN SWEAT SOLDERING Tubing Cutters or Hacksaw Propane Torch Basic Tools You may or may not need all of these tools depending on your type of installation These tools can be purchased at your local Sears store Soft Solder Pipe Wrench 2 14 Soler Aen Screwdriver mery Clot 6 Foot Tape or Folding Rule Garden Hose Drill Pipe Dope or Teflon Tape Wire Brushes
21. MPERATURE SHUT OFF SYSTEM cont d Remove the two screws securing the access panel and remove panel Open the flap of insulation to expose the opening Reset the high limit by pushing in the red button marked RESET RESET BUTTON Fold the insulation back in place so that it completely covers the thermostat and element Replace the access panel ON electric power to the water heater A CAUTION If the high limit must be reset again call Sears Service Department to find out why the high limit turned the electric power 20 NOT ENOUGH OR NO HOT WATER In a new installation the water heater may not be properly connected Make sure the cold water supply valve is open Review and check piping installation Make sure that the cold water line is connected to the cold water inlet to the water heater and the hot water line to the hot water outlet on the water heater Make sure the electrical supply to your water heater is 53 ON Check for loose or blown fuses in your water heater circuit Circuit breakers weaken with age and may not handle their rated load and should be replaced Make certain the disconnect switch if used is in the ON position Check to see the electric service to your house has not been interrupted If this is the case contact the electric company Is the thermostat set to the desired temperature See Temperature Regulation section
22. PERTY DAMAGE 2 Take off the access panel and fold away the insulation 3 Turn the water temperature dial clockwise CN to increase the temperature or counter clockwise Y N to decrease the temperature 4 Fold the insulation back in place and replace the access panel 5 Turn ON the power supply Service and Adjustment cont d Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be man ually operated at least once a year TEMPERATURE PRESSURE RELIEF VALVE 7 DISCHARGE A WARNING The temperature pressure relief valve must be manually operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 the water manually discharged will not cause any property damage or bodily injury The water may be extremely hot if after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the drain ing instructions and replace the temperature pressure relief valve with a new one Failure to install and maintain a new properly listed temperature pressure relief valve will release the manufacturer from any claim which might result from excessive temperature or pressure A WARNING If the temperature pressure relief valve on the appliance
23. and the tank Do not connect tubing directly to discharge drain unless a 6 air gap is provided To prevent bodily injury hazard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage The Discharge Pipe Must not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restriction Must not be plugged or blocked Must be of material listed for hot water distribution Must be installed so as to allow complete drainage of both the temperature pressure relief valve and the dis charge pipe Must terminate at an adequate drain Must not have any valve between the relief valve and tank WARNING The temperature pressure relief valve must be manually operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the drain ing instructions and replace the temperature pressure relief valve with a new one
24. approximately 4 away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely disconnected and ready to be removed G b If you have galvanized pipe to the water heater loosen the two gal vanized pipes with a pipe wrench at the union in each line Also disconnect the piping remaining to the water heater These pieces should be saved since they may be needed when reconnecting the new water heater Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely disconnected and ready to be removed A CAUTION Mineral buildup or sediment may have accumulated in the old water heater This causes the water heater to be much heavier than normal and this residue if spilled out could cause staining Installation Instructions Facts to Consider About the Location You should carefully choose an indoor location for the new water heater because the placement is a very important consid eration for the safety of the occupants in the building and for the most economical use of the appliance This water heat
25. codes but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 CSA 4 4 by a nationally recog nized testing laboratory that maintains periodic inspection of production of listed equipment or materials The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater 150 Ibs sq in and a discharge capacity not less than the water heater input rate as shown on the model rating plate Electric heaters watts divided by 1000 x 3412 equal BTU Hr rate Your local jurisdictional authority while mandating the use of a temperature pressure relief valve complying with ANSI Z21 22 CSA 4 4 and ASME may require a valve model different from the one furnished with the water heater Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally pre scribed temperature pressure relief valve installed in the desig nated opening in the water heater in place of the factory fur nished valve For safe operation of the water heater the relief valve must not be removed from it s designated opening or plugged The temperature pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve Position the valve downward and provide tubing so that
26. e of purchase for a water heater used a single family residence if a leak occurs in SA b H o x the tank Sears will furnish a new current model water heater of equal capacity and quality You will be charged for any QU S 2 cj installation Bes 6 S 225 229 o3 7 3 B B v I To obtain warranty service SIMPLY CALL 1 800 4 1 800 469 4663 This warranty applies only while this 5 AS RY product is in use the United States 59 225 27555 5 PM 2 gt 09 This warranty gives you specific legal rights and you may also have other rights which vary from state to state 09 lt gt x f IRE 2525 SEARS ROEBUCK AND CO Dept 817 WA HOFFMAN ESTATES IL 60179 2525 9 ree lt gt OX 225 27555 o3 On o O O O ON ON ON O O O O O O O AR The price of your water heater does not include a free checkup service call On water heater installations arranged by Sears Sears warrants the installation A charge will be made on service calls due to poor or incomplete installation These include a Adjusting thermostat b Leaks in pipes or fittings Condensation MASTER PROTECTION AGREEMENTS Congratulations on making a smart purchase Your new Kenmore prod uct is designed and manufactured for years of dependable operation But like all products it may requ
27. eater filled with water additional bracing will be necessary Two possibilities are shown below WALL STUDS MD MIN 2 MIN 2 x 4 WHICH LAPS AT LAPING LEAST TWO WALL STUDS LEAST TWO WALL STUDS BA x 3 WOOD SCREWS WATER HEATER MOUNTING BRACKETS d Figure 2 Figure I 1 Using two sheet metal screws supplied secure the top mount ing bracket to the top of the water heater SECURING SCREWS gy SUPPLIED g H 18 18 UPPER BRACKET 4 2 Using the remaining two sheet metal screws provided secure the bottom mounting bracket to the bottom of the water heater LOWER BRACKET SECURING SCREWS SUPPLIED 88 18 x Installation Instructions Optional Wall Mounting cont d 3 Determine the location on the wall and then the D above the floor which the wall securing bracket will be placed Using adequate screws or nuts and bolts not sup plied fasten the wall securing bracket to the wall SECURING SCREW WALL MIN 12 NOT SUPPLIED uU SECURING SCREW TO WALL MIN 12 x 34 NOT SUPPLIED 222 222222274 Water Piping HOTTER WATER CAN SCALD Water heaters are intend ed to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish wash ing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be
28. efore beginning turn OFF the electrical power supply to the water heated A WARNING HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Failure to do this could result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Follow Draining instructions in the Service and Adjustment section Turning counter clockwise remove the hex cap below the screw handle Remove the washer and put the new one in place Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN Follow Filling the Water Heater instructions in the Installation Instructions section Check for leaks Turn ON electric power to the water heater HANDLE AND CAP ASSEMBLY WASHER Service Before calling for repair service read the Start Up Conditions and Operational Conditions found in the Troubleshooting Guide of this manual If a condition persists or you are uncertain about the operation of the water heater let a qualified person check it out Contact SEARS Repair Services at 1 800 4 MY HOME 1 800 469 4663 Troubleshooting Guide Start Up Conditions THERMAL EXPANSION Water supply systems may because of such events as high line pressure frequent cut offs the effects of water hammer among others have installed devices such as press
29. er is not intended for outdoor installation Whether replacing an old water heater or putting the water heater in a new location the following critical points must be observed The location selected should be indoors as close to and as centralized with the water piping system as possible This water heater as well as all water heaters will eventually leak Do not install without adequate drainage provisions where water flow will cause damage CAUTION WATER HEATERS EVENTUALLY LEAK Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak the flow of water will not cause damage to the structure When such locations cannot be avoided a suitable drain pan should be installed under the water heater Drain pans are avail able at your local Sears stores Such a drain pan must be piped to an adequate drain A CAUTION INSTALLATION IN RESIDENTIAL GARAGES The water heater must be located and or protected so it is not subject to physical damage by a moving vehicle The location selection must provide adequate clearances for servicing and proper operation of the water heater Optional Wall Mounting Wall construction at the point of the water heater instal lation must be capable of supporting at least 200 pounds As an example if the water heater is to be installed on a wall of gypsum board dry wall or other material not capable of sup porting the water h
30. f the water heater 150 Ibs sq in and a discharge capacity not less than the water heater input rate as shown on the model rating plate Electric heaters watts divided by 1000 x 3412 equal BTU Hr rate Your local jurisdictional authority while mandating the use of a temperature pressure relief valve complying with ANSI 721 22 CSA 4 4 and ASME may require a valve model dif ferent from the one furnished with the water heater Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally prescribed temperature pressure relief valve installed in the designated opening in the water heater in place of the facto ry furnished valve For safe operation of the water heater the relief valve must not be removed from it s designated opening or plugged The temperature pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve Position the valve downward and provide tubing so that any discharge will exit only within 6 inches above or at any distance below the structural floor Be cer tain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve
31. hese conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used such as a dishwasher or washing machine If hydrogen gas is pre sent there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened There must be no smoking or open flame near the faucet at the time it is open 19 RUMBLING NOISE In some water areas scale or mineral deposits will build up on your heating elements This buildup will cause a rumbling noise Follow Element Cleaning Replacement instructions to clean and replace the elements HIGH TEMPERATURE SHUT OFF SYSTEM The water heater has a high limit shut off system with a reset button located on the thermostat Follow the resetting instructions which refer to the high limit behind the access panel Before beginning turn OFF electrical power supply to the water heater HOM Ta EEJ 5 Ei SE IL EEE i lay ir dieit il i SIMI SUE 8 Hx 1571 ET HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Failure to do this could result in DEATH SERI OUS BODILY INJURY OR PROPERTY DAMAGE Troubleshooting Guide cont d HIGH TE
32. ials and Basic Tools Needed Materials Needed Reise nut Or ccu eei Rr E DNE EM Installation Instructions Removing the Old Water ED EP D Ie obesse Facts to Consider About the Tocationzz eec eee Optional Wall Mounting eoi eiae Anki Aed eaaa i dicte eniti eei rene gO Water Piping cuite nies Lade tva cie oca beet Lao deae eid Temperature Pressure Relief Valve setenta eee ge Pilling the Water Heater stetesdetsetetet eterni eet Optional Cord See inten eet re E te ne t debo ar re taedet Rete tei e be Peers 10 a dtnIsbrr Il TM T 10 hann EE 11 Installation Checklist iie c esit ese cisco treo 12 Service and Adjustment Regulation ecce 13 T helostatszd ete UE 13 Lem peratitre Settings 13 Thermostat Adjustment ete ene heiter Ie ert e bes tione 13 Tein
33. ion Inlet Water Heater Capacity Gallons Tank Water Capacity Pressure 2 4 6 10 19 9 Needed 40 80psi 2 2 2 2 2 Highest recorded inlet water pressure in a 24 hour period or regulated water pressure NOTE Expansion tanks are pre charged with a 40 psi air charge If the inlet water pressure is higher than 40 psi the expansion tank s air pressure must be adjusted to match that pressure but must not be higher than 80 psi 18 WATER HEATER HOT A COLD WATER PRESSURE S INLET FITTING REDUCING VALVE WITH BY PASS 12224 EXPANSION TANK INLET WATER SHUTOFF RECOMMENDED INSTALLATION VERTICAL MOUNTING PRESSURE GAUGE WATER HEATER FLOOR CEILING COLD WATER JOIST ETC INLET FITTING STRAPPING 3 PRESSURE REDUCING INLET COLD VALVE WITH WATER BY PASS SHUTOFF 1 EXPANSION TANK PRESSURE GAUGE ALTERNATE RECOMMENDED INSTALLATION HORIZONTAL MOUNTING STRANGE SOUNDS Possible noises due to expansion and contraction of some metal pen during periods of heat up and cool down do not represent armful or dangerous conditions Troubleshooting Guide Operational Conditions SMELLY WATER In each water heater there is installed an anode rod for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell
34. ire preventive maintenance or repair from time to time Thats when having a Master Protection Agreement can save you money and aggravation Purchase a Master Protection Agreement now and protect yourself from unexpected hassle and expense The Master Protection Agreement also helps extend the life of your new product Heres what s included in the Agreement Expert Service by our 12 000 professional repair specialists Unlimited service and no charge for parts and labor on all covered repairs No lemon guarantee replacement of your covered product if four or more product failures occur within twelve months Product replacement if your covered product cant be fixed Annual Preventive Maintenance Check at your request no extra charge Fast help by phone phone support from a Sears technician on products requiring in home repair plus convenient repair scheduling Power surge protection against electrical damage due to power fluc tuations Rental reimbursement if repair of your covered product takes longer than promised Once you purchase the Agreement a simple phone call is all that it takes for you to schedule service You can call anytime day or night or sched ule a service appointment on line Sears has over 12 000 professional repair specialists who have access to over 4 5 million quality parts and accessories That s the kind of profes sionalism you can count on to help prolong the life of yo
35. ons The installation must conform with the instructions in this manual electric company rules and Local Codes or in the absence of Local Codes with the current edition of the NEC National Electrical Code NFPA 70 This publication is available from your local government or public library or electric compa ny or by writing Underwriters Laboratories Inc 333 Pfingsten Road Northbrook IL 60062 If after reading this manual you have any questions or do not understand any portion of the instructions call Sears Service Center Carefully plan the place where you are going to put the water heater Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires Examine the location to ensure the water heater com plies with the Facts to Consider About the Location section For California installation this water heater must be braced anchored or strapped to avoid falling or moving during an earthquake See instructions for correct installation procedures Instructions may be obtained from your local dealer whole saler public utilities or California Office of the State Architect 400 P Street Sacramento CA 95814 Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248 CMR 2 00 State Plumbing Code and 248 CMR 5 00 MAXIMUM FUSE TANK RECOVERY RATE ELEMENT MINIMUM OR CIRCUIT MODEL CAPACITY DIMENSIONS IN INCHES GA
36. perature Pr ssure Relief Valve Operation iiis eite Dh nne beso p AEE acea 14 Draining xat EE bl eite tete adio ro E eee EN 14 Element Cleaning Replacement 5 essen 15 17 Drain Valve Washer 17 SERVICES ss dete stad S esie Ep E o tue od ce 17 Troubleshooting Guide Stirt Up Conditions TER 18 Thermal Expansion er ipti em cede 18 Serange Sounds 18 Operational Conditions ec seeds eel Seda a OR eh na 19 20 Smelly Water bounces LI Air in Hot Water Faucets eie NE TIE db diis 19 Rambling E 19 High Temperature Shut Of korena ai iel E eraa sa EA E ea 19 20 Noe Enough or No Hot Water 20 Water ts GO AE AE ISET TES iaa etd A EER EEA SE SE S 20 Leakage Checkpoints ID
37. permanently injured by hot water than others These include the elderly children the infirm or physically men tally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addi tion to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve shall be used at the hot water taps used by these peo ple or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturers instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual INLET d COLD WATER INLET ON LRL WATER HEATER e VALVE ON WATER HEATER If a water heater is installed in a closed water supply system such as one having a back flow preventer check valve water meter with a check valve etc in the cold water supply means must be provided to control thermal expansion Contact the local utility or Sears Service Center on how to control this situation The illustration shows the attachment of the water piping to the water heater The water heater is equipped with 4 water connections Look at the top of the water heater The hot water outlet is marked hot Put two or three turns of teflon
38. pply Systems ANS Z21 22 by a nationally recognized fast ing laboratory that maintains periodic inspection of production of listed equipment or materials The valve must be oriented provided with tubing or otherwise installed so that discharge can exit only within 6 inches above or at any distance below the structural floor and cannot contact any five electrical part For safe operation of the water heater the Relief Valve must not be removed or plugged See manual heading Temperature Pressure Relief Valve for installation and maintenance of Relief Valve discharge pipe and other safely precautions Installation Instructions Filling the Water Heater fill the water heater with water Close the water heater drain valve by turning the handle to the right clockwise The drain valve is located on the lower front of the water heater Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use insure complete filling of the tank allow air to exit by opening the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping CAUTION Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning
39. s panel for the correct voltage DO NOT use this water heater with any voltage other than the one shown on the model rating plate Failure to use the correct voltage can cause problems which can result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE If you have any questions or doubts consult your electric company A CAUTION If wiring from your fuse box or circuit breaker box was aluminum for your old water heater replace it with copper wire If you wish to reuse the exist ing aluminum wire have the connection at the water heater made by a competent electrician Contact your Sears salesperson to arrange for a professional electrician 1 Provide a way to easily shut off the electric power when working on the water heater This could be with a circuit breaker or fuse block in the entrance box or a separate dis connect switch 2 Install and connect a circuit directly from the main fuse or circuit breaker box This circuit must be the right size and have its own fuse or circuit breaker Refer to the chart in the Product Specifications section for the correct size wire and fuse or circuit breaker 3 If metal conduit is used for the grounding conductor A The grounding electrode conductor shall be of copper aluminum or copperclad aluminum The material shall be of one continuous length without a splice or joint 11 Rigid metal conduit intermediate metal conduit or elec trical metallic tubing may be
40. ter A CAUTION Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot water faucet before turning power Service and Adjustment cont d Element Cleaning Replacement To remove the element from your tank in order to clean or replace it The water passing out of the drain valve may be 1 Before beginning turn OFF the electric power supply to the extremely hot To avoid being scalded make sure all water heater connections are tight and that the water flow is directed away from any person 4 Remove the two screws securing the access panel and remove C 11 ATQ panel i AUi HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Failure to do this could result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE 2 Turn off the water supply to the water heater at the water shutoff valve or water meter 6 Lift out the tab as shown to unclip the terminal cover from the thermostat The terminal cover can now be removed from the thermostat 3 Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors Open the water heater drain valve Open a nearby hot water faucet which will relieve pressure in the
41. ur new purchase for years to come Purchase your Master Protection Agreement today Some limitations and exclusions apply For prices and additional information call 1 800 827 6655 SEARS INSTALLATION SERVICE For Sears professional installation of home appliances garage door open ers water heaters and other major home items in the U S A call 1 800 4 MY HOME For in home major brand repair service Call 24 hours a day 7 days a week U S A and Canada 1 800 4 MY HOME 1 800 469 4663 www sears com The model number of your water heater is found on the model rating plate on the front of the water heater Sears Roebuck and Co Hoffman Estates IL 60179 U S A
42. ure reducing valves check valves back flow preventers etc to control these types of roblems When these devices are not equipped with an internal and other measures taken the devices cause the water system to be closed As water is heated it expands ther mal expansion and closed systems do not allow for the expan sion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion This is an unacceptable condition and must be cor rected It is recommended that any devices installed which could create a closed system have a by pass and or the system have an expan sion tank to relieve the pressure built by thermal expansion Thermal expansion tanks are available from Sears stores and through the Sears Service Centers Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations Thermal Expansion Tank Specifications Model Tank Capacity Dimensions in Inches Pipe Fitting Number In Gallons Diameter Length Tank 153 331020 2 8 inches 127 inches Male Expansion Tank Sizing Chart Expans
43. ure to do this could result in DEATH SERI OUS BODILY INJURY OR PROPERTY DAMAGE A WARNING HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a tem perature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain tem perature water at the hot water tap then you must take special precautions In addition to using the lowest possi ble temperature setting that satisfies your hot water needs a means such as a mixing valve shall be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturers instructions for installation of the valves Before changing the factory set ting on the thermostat read the Temperature Regulation section in this manual A WARNING WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY This water heater is equipped for one type voltage only Check the rating plate near the bottom access panel for the correct voltage DO NOT use this water heater with any voltage other than the one shown on the model rating plate
44. used for the grounding means if conduit or tubing is terminated in fittings approved for grounding C Flexible metal conduit or flexible metallic tubing shall be permitted for grounding if all the following conditions are met 1 The length any ground return path does not exceed 6 feet The circuit conductors contained therein are protect ed by overcurrent devices rated at 20 amperes or less The conduit or tubing is terminated in fittings approved for grounding For complete grounding details and all allowable exceptions refer to the cur rent edition of the National Electrical Code NFPA 70 A standard 4 conduit opening has been made in the water heater junction box for the conduit connection Use wire nuts and connect the power supply wiring to the wires inside the water heater s junction box The water heater must be electrically grounded by the installer A green ground screw has been provided on the water heater s junction box Connect ground wire to this location Replace the wiring junction cover using the screw provided GREEN GROUND SCREW CCA HEATER WIRING Installation Instructions Installation Checklist Is the fuse or circuit breaker size correct as shown in the chart in the Product Specifications section Are the wires from the circuit breaker or fuse service to the water heaters junction box on the correct wire size gauge as shown in the chart in
45. water heater and speed draining 7 how x oan 7 re L Em 1 j Soe co Service and Adjustment cont d Element Cleaning Replacement 7 Disconnect the two wires on the element and unscrew the old element from the rank 8 Clean the area around the element opening Remove any sediment from or around the element opening inside the tank 9 If you are cleaning the element you have removed do so by scraping or soaking in vinegar or a de liming solution A WARNING Replacement elements must 1 be the same volt age and 2 no greater wattage than listed on the model rating plate affixed to the water heater 10 A new gasket should be used in all cases to prevent a possible water leak See Element Gasket in the Parts Order List Chart Place the new element gasket on the thread side of the cleaned or new element and screw into tank securing tightly using an element wrench 11 Close the water heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of the water heater 12 Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use 13 To insure complete filling of the tank allow air to exit by opening the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping CAUTION
46. weeps or discharges periodically this may be due to ther mal expansion Your water heater may have a check valve installed in the water line or a water meter with a check valve Consult your local Sears Service Center for further information Do not plug the temperature pres sure relief valve Draining The water heater should be drained if being shut down during freezing temperatures Also periodic draining and cleaning of sediment from the tank may be necessary Before beginning turn OFF the electric power supply to the water heater A WARNING HAZARD OF ELECTRICAL SHOCK Before removing any access panels or servicing the water heater make sure the electrical supply to the water heater is turned OFF Failure to do this could result in DEATH SERI OUS BODILY INJURY OR PROPERTY DAMAGE CLOSE the cold water inlet valve to the water heater OPEN a nearby hot water faucet and leave open to allow for draining Connect a hose to the drain valve and terminate to an adequate drain or outdoors OPEN the water heater drain valve to allow for tank draining NOTE If the water heater is going to be shut down and drained for an extended period the drain valve should be left open with hose connected allowing water to terminate to an adequate drain Close the drain valve Follow Filling the Water Heater instructions in the Installation Instructions section Turn power to the water hea