1. Rear Optional Equipments Isolation transformer AA V31U B Input 120V AC 3 1 A 60 Hz E Output 120 V AC 3 0A 60 Hz E Weight 6 7kg E Accessories Plug retainer bracket x 3 Torx head screw x 8 Cover plate x 3 Flat washer x 3 Split locking washer x 3 HD monitor DT V1900CG Power requirements 120V 60 Hz E Power consumption 1 6A E Dimensions 476 mm W x 407 5 mm H x 529 mm D E Weight 31 6 kg W VHS VCR SR W7MAU E Power requirements 120V AC 60 Hz E Power consumption 43W E Dimensions 476 mm W x 148 mm H x 366 mm D E Weight 10 kg Endoscope Adapter DZ E3U Focal length 24 mm Camera Mount C Mount Sterilization Applicable for EO Weight 51g 1 8 oz Zoom endoscope adapter DZ E33U Focal length 13mm to 26mm Camera Mount C Mount Sterilization Applicable for EO Weight 102g 3 6 oz TECHNICAL AND SERVICE ASSISTANCE JVC offers technical and customer service assistance Please contact us at the following address Importer s name amp address J P C JVC PROFESSIONAL PRODUCTS COMPANY 1700 Valley Road Wayne NJ 07470 TEL 973 317 5000 FAX 973 317 5030 Warranty and after sales service Warranty record confirmation and safekeeping This product is sold with a warranty card attached Warranty card has been delivered to sales dealer of this product Please check your particulars and the record after filling and keep it
2. SXGA output 700 TV lines TYP HD Y output SXGA output 52dB F6 8 2000 Ix 51x Internal sync external sync Composite sync signal of 0 3 Vp p 75 ohms BNC x 1 ITU R Rec BT 709 3 HDTV standard compliant Full color bar Horizontal dual edged 7 step variable Vertical dual edged 7 step variable 1 60 s normal 1 100 s 1 175 s 1 250 s 1 375 s 1 500 s 1 1000 s 1 2000 s 1 4000s 1 10000s R G B 0 7 Vp p 75 ohms HD VD TTL D Sub mini 15 pin Y 1 Vp p Pb Pr 0 7 Vp p 75 ohms BNC x 3 VBS 1 Vp p 75 ohms BNC Y C 1 Vp p 75 ohms S terminal IEEE1394 6 pins 19 pins Menu system 1 Year month day 2 Day month year 3 Month day year Menu system hour minute second 120V AC 60Hz 0 7A Class 5 to 35 41 F to 95 F 35 75 20 C to 50 4 F to 102 F 35 80 280 W x 140 H x 300 D mm 11 3 16 x 5 9 16 x 11 13 16 excluding the protrusion and switches etc 5 5 kg 12 1 Ibs Power cord x 1 Instruction manual x 1 Warranty card x 1 E Outer dimensions Camera head o 57 2 1 5 43 12 7 44 jet N N C 57 7 a Front Side Rear Bottom Camera control unit 280 CAMERA CONTROL UNIT OUTPUT LEVEL WHITE BALANCE MENU SETTING z bred ADJUST Front Side
3. is provided or the manufacturer s instructions have been adhered to 6 Storage Location Do not store this product in a humid location such as near a window or an air conditioner nor in a hot loca tion such as near a heater 7 Disposing of the Product Always sterilize this product before disposing of it See page 6 When discarding equipment environmental problems must be considered and the local rules or laws govern ing the disposal must be followed strictly USE 1 Accessories To avoid personal injury Do not place this product on an unstable cart stand tripod bracket or table It may fall causing serious injury to a child or adult and serious damage to the product Use only with a cart stand tripod bracket or table recommended by the manufacturer or sold with the product Use a mounting accessory recommended by the manufacturer and follow the manufacturer s instruc tions for any mounting of the product Do not try to roll a cart with small casters across thresholds or deep pile carpets 2 Product and Cart Combination provided bY RETAG A product and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart combination to overturn 3 Water and Moisture Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the lik
4. temperature refer to page 20 Connections E Connection example DT V1900CG Optional c ET Endoscope adapter Optional Endoscope Commercially available 556 22 950059299 G Camera head SR W7MAU Optional W VHS Connector Cap Video S Y C Out 120V Notes Use the above composition of device or its equivalent Do not connect this camera to equipment other than that depicted in these connection diagrams When connecting monitors VTR etc to the camera control unit please rely on a qualified serviceman to check that the increased current leakage does not surpass the regulated level during initial connection e If the isolation transformer cabinet is corroded please approach your local authorized dealer to have it replaced Name of parts and their functions Camera control unit front panel micro HD CAMERA CONTROL UNIT OUTPUT LEVEL WHITE BALANCE MENU SETTING ENHANCE FREEZE BAR OOl o o o 1 POWER power switch and power indication o WHITE BALANCE white balance control sec LED tion When switching power on again after it is just Adjust white balance automatically or manually switched off Wait for more than 5 seconds before
5. Our company is not responsible for the use of this product and the performance of this product when during its use natural disaster such as earthquake fire or electric power shutdown occurs Concerning backup and others they are solely the responsibility of the doctors or the hospital Our company is not responsible for the result of using this product if the warnings and operating methods printed in this Instruction Manual are not followed VICTOR COMPANY OF JAPAN LIMITED COPYRIGHT 6 2002 VICTOR COMPANY OF JAPAN LTD e Printed in Japan 0902 MN SW SW NEVOA Zd
6. PB with B volume control If measuring instrument is not available adjust the picture on the monitor screen until it turns white In this case high precision white balance cannot be obtained Basic operation Continued 7 5 Connector Cap Mark Red MEN gt Camera head CCU Camera control unit DZ VCA3U SR W7MAU W VHS Optional DT V1900CG Optional A Isolation transformer AA V31U AC 120V Optional Operation of Micro HD camera Check system operation according to the following procedures 1 Insert the camera connector while aligning it to the red mark as shown on the left figure When cap is connected to the camera connector Turn the cap counterclockwise to remove it 2 Connect the endoscope adapter to the C mount of camera head 3 When operating this system set the switches on the CCU panel as follows 1 OUTPUT LEVEL _ AUTO 2 WHITE BALANCE AUTO 3 MENU SETTING OFF 4 Switch on DZ VCA3U power 5 Adjust the white balance System operation Check system operation according to the following procedures 1 Insert the camera connector while aligning it to the red mark as shown on the left figure When cap is connected to the camera connector Turn the cap counterclockwise to remove it 2 When the camera is used as a system connect the power plugs of the camera and othe
7. properly E Warranty period Warranty period is one year from the date of purchase Thereafter service will be chargeable Servicing will be done by sales dealer based on record written in warranty card However compensation other than service guarantee will not be entertained Business opportunity loss due to damage will not be entertained For further details please refer to warranty card Servicing after expiry of warranty period Please consult sales dealer for servicing after expiry of warranty period In the case of maintaining function through service servicing will be performed according to the wish of customer and it will be chargeable E After sales service inquiry counter For after sales service inquiry consult sales dealer or nearest service counter listed in Service Counter Guides Escape clause Using this product for medical treatment is the decision and responsibility of medical doctors Our company is not responsible for treatment result using this product Our company is not responsible for any damage to this product due to removal servicing inspection and modifi cation unless it is handled by our company authorized dealer During delivery or redelivery of this product the responsi bility to sterilize it belongs to the doctor or the hospital Our company is not responsible if this product becomes a medium in transmitting bacteria to doctors technicians nurses patients etc
8. resolution 700 TV lines The aspect ratio is 4 3 System construction HDTV studio standard compliant with ITU R Rec BT 709 3 sync signals are used allowing recorded picture to be played back with high picture quality when an HDTV VCR such as the W VHS VCR is used Automatic sensitivity control The automatic sensitivity control combines automatic sensitivity control with ALC and electronic iris ALC EEI to allow trouble free shooting Electronic shutter function A built in 1 10000 sec electronic shutter function allows capture and analysis of fast moving subjects Color bar generator A full color bar generator is built in for easy system adjust ment Automatic internal external sync switching Useful for systematic operations such as multicamera video processing in combination with other devices 2H contour provided as standard Contour compensation is performed both horizontally and vertically to assure sharp clear pictures Applications Micro HD camera system can be used for following application Endoscope operation in OR This system should only be operated by doctors or authorized persons Above application the system can supply HD and SD signals to HD SD monitor for display and to HD SD VTR for recording playback Electrical energy can perform many useful functions But improper use can result in potential electrical shock or fire hazards This product has been engineered and manufactured to as
9. switching it on o Manu control section Display menu to do various settings CAMERA camera cable connector Connect to camera head control section ON OFF setting of enhance freeze and colour bar e OUTPUT LEVEL output level controller section Set output level automatically or manually Set adjustment combining gain and shutter here Camera control unit rear panel p AC INPUT power input connector To input AC120V o Equal potential connector Cover for extension slot Remove the cover to install an optional device in this slot NTSC OUTPUT NTSC output section Output of DV signals Y C S signals VBS compos ite video signals The power supply for IEEE1394 interface is not available from DV connector Camera head Lens mount ring Standard C mount is used Flange back will be 17 526mm in air e Camera cable connector plug Connect to camera control unit G GENLOCK IN OUT sync signal input output Input output of composite sync signal for external sync menu based switching SXGA OUT SXGA output section Output of progressive scan GBR signal SXGA output signal cannot be displayed on the DT V1900CG Use the monitor that is compliant with the following scanning frequency Horizontal 67 4325kHz vertical 59 94Hz HD OUT video sign
10. the picture on the monitor while the electronic shutter is being used the object movement appears to be discontinuous For example in shutter speed of 1 2000 sec Since the image for 1 2000 sec is taken out every 1 60 sec this phenomenon occurs When high speed shutter is used light may not be suffi cient White balance control section r WHITE BALANCE CAMERA CONTROL UNIT AUTO SETTING RED WHITE BALANCE switch SETTING button R B button AUTO When set to this position the camera is automatically set to a pre adjusted white balance To automatically readjust the while balance use SETTING button MANUAL When adjusting the white balance manually set to this position Adjustment is done through R B volume Names of parts and their functions continued Mode control section CAMERA CONTROL UNIT OUTPUT LEVEL WHITE BALANCE MENU SETTING ENHANCE button To set enhance By pressing this button LED will light up and the enhance will be functional Press it again then LED will light off and the emphasis will disappear FREEZE button By pressing this button LED will light up and frame Still mode engaged Press it again then LED and FREEZE mode will disappear Menu control section CAMERA CONTROL UNIT OUTPUT LE
11. F No display INDICATION3 menu Set the display on the bottom right of NTSC OUT screen Selection items and functions are as follows Selection item Function DATE amp TIME Displays date and time TIME Displays only time OFF No display TIME amp ID CODE Displays the content set in time and under ID CODE menu DATE amp TIME amp ID CODE Displays the content set in date and time and under ID CODE menu Names of parts and their functions continued ID CODE menu Edit ID CODE that can be displayed on the screen Select from INDICATION 1 3 menu to see if it can be displayed Message is up to 22 alphanumeric characters e Characters that can be used A Z 0 9 and space DATE amp TIME menu To change date and time setting and date display format DATE sub menu Use the LEFT RIGH T button to select the part of the date to be changed the numbers will blink and use the UP DOWN button to set the new value TIME sub menu Use the LEFT RIGHT button to select the part of the time to be changed the numbers will blink and use the UP DOWN button to set the new value DATE FORM sub menu Use the LEFT RIGHT button to select one of the following three formats year month day day month year month day year The month of day month year month day year of HD OUT and SXGA OUT will be displayed in English short form SYNC menu Switching between sending GENLOCK basic sign
12. Instructions MICRO HD CAMERA DZ VCA3U For customer Use Enter below the Serial No which is located on the side panel of the cabinet Retain this information for future reference Model No Serial No LYT1053 001B Contents Applications m Q 3 Precautions on installing medical electrical equipment Safety and hazard prevention 3 Safety precautions nannan 4 Important product safety instructions 5 dicli mee t 7 Safety precautions iter teer 7 Handling precautions airina Inspection and maintenance 8 Camera Head Section sese 8 Phenomena peculiar to 05 8 Connections atn ne naar 9 Names of parts and their 10 Camera control unit front panel 10 Camera control unit rear panel 11 Camera head aciei een o ea tees 11 Output level control section 12 White balance control section 13 Mode control section
13. VEL WHITE BALANCE MENU SETTING CAMERA MENU switch ON The menu is displayed on the screen Selection of menu item is done with the CURSOR button OFF The menu is not displayed ENHANCE FREEZE BAR H BAR button By pressing this button LED will light up and Full Color Bar will be displayed Press it again then LED will disappear and camera signal restored MENU SETTING D CURSOR button When the mark appears on the left of the menu item it indicates that the item is selected When the up arrow or down arrow W appears on the left of the menu item it indicates that the item can be selected with UP DOWN CURSOR button When the right arrow We or left arrow lt q appears on the right of the menu item it indicates that the item can be selected with LEFT RIGHT CURSOR button INDICATION1 menu Set the display on the top left of HD OUT and SXGA OUT Screen Selection items and functions are as follows Selection items Functions ID CODE Displays the content set under ID CODE menu GAIN amp SHUT Displays the gain value and shutter value OFF No display INDICATION2 menu Set the display on the top right of HD OUT and SXGA OUT Screen Selection items and functions are as follows Selection item Function DATE amp TIME Displays date and time TIME Displays only time OF
14. al or input basic signal from other device Basic operation White balance adjustment AUTO SETTING button WHITE BALANCE WHITE BALANCE AUTO MANUAL switch SETTING RED BLUE MANUAL WHITE BALANCE switch WHITE BALANCE AUTO 1 MANUAL SETTING RED BLUE R B volume control While watching the monitor shoot a white object with full screen under the same lighting condition as actual shooting Set the WHITE BALANCE switch to AUTO When you press and hold SETTING button AUTO WHITE will blink at the upper left corner of the screen When white balance adjustment is complete the indication changes to AUTO WHITE OK If the indication at the upper left corner of the monitor screen does not changes to AUTO WHITE OK it means white balance adjustment has not been completed Check the following items and retry auto white balance adjustment 1 Is lighting sufficient Adjust the lighting Oris lighting too bright 2 Did you shoot a coloured object Shoot a white object Connect a measuring instrument such as a waveform monitor to the HD output jack and adjust the white balance while watching the waveform First set the WHITE BALANCE switch to MANUAL Adjust and Pr output amplitudes to the minimum with R B volume controls Adjust Pr with R volume control and
15. al output section Output of HD Y video signals interlace scan When HD video signals are connected to Hi vision monitor the screen will have a width length ratio of 16 9 and the picture will extend sideways Names of parts and their functions continued Output level control section GAIN switch AUTO OUTPUT LEVEL MANUAL ADJUST Adjusts gain automatically In this mode the GAIN UP GAIN DOWN button and SHUTTER UP SHUTTER DOWN button operations are disabled MANUAL Set to this position when adjust the GAIN and SHUTTER manually ADJUST volume Set the brightness during auto sensitivity adjustment Enabled only when GAIN switch is set to AUTO GAIN UP GAIN DOWN button GAIN UP Each time this button is pressed the gain increases by 1 dB GAIN DOWN Each time this button is pressed the gain decreases by 1 dB CAMERA Enabled only when GAIN switch is set to MANUAL Setting from 3dB to 24dB is possible CAMERA CONTROL UNIT OUTPUT LEVEL WHITE BALANCE MENU SETTING Auto il o SHUTTER UP SHUTTER DOWN button Using the SHUTTER UP SHUTTER DOWN button the following setting is possible 1 60 1 100 1 175 1 250 1 375 1 500 1 1000 1 2000 1 4000 1 10000 Enabled only when GAIN switch is set to MANUAL When looking at
16. ck hazards please use only the equipment specified in this instruction manual Important product safety instructions INSTALLATION AND DISPOSAL 1 Grounding or Polarization Precautions should be taken so that the grounding or polarization of an appliance is not defeated 2 Power Sources Operate your product only from the type of power source indicated on the marking label If you are not sure of the type of power supply to hospital consult your product dealer or local power company If your product is intended to operate from battery power or other sources refer to the operating instructions 3 Overloading Do not overload wall outlets extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock 4 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the product 5 Ventilation Slots and openings in the cabinet are provided for ventilation To ensure reliable operation of the product and to protect it from overheating these openings must not be blocked or covered Do not block the openings by placing the product on a bed sofa rug or other similar surface Do not place the product in a built in installation such as a bookcase or rack unless proper ventilation
17. e 4 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the product 5 Attachments Do not use attachments not recommended by the manufacturer of this product as they may cause hazards 6 Cleaning Unplug this product from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 7 Sterilization Before using the endoscope always be sure to sterilize the endoscope adapter mounted HD cam era head with the cable 8 Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products including amplifiers that produce heat Important product safety instructions Continued SERVICING 1 Servicing Should the product fail to work normally do not attempt to fix it yourself Please rely on a qualified service person Note Before returning the camera head endoscope adapter be sure to sterilize the camera head with cable and endoscope 2 Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the product c If the product has b
18. e endoscope adapter to the camera head align it to the screw of C mount on the camera head and turn the endoscope adapter clockwise to tighten it The O ring of the adapter makes the system waterproof The connecter of the camera cable should be connected with cap Sterilize the system under the above situation Precautions Safety precautions Do not damage or modify the power cable Doing so could result in current leakage or electric shock To protect the camera and avoid electric shock hazards always disconnect the power cord of the camera control unit from the AC outlet when the camera is not in use for an extended period Make sure that no flammable objects water or bits of metal get inside the unit These could damage the unit or cause a malfunction Whenever an anomaly unusual noise smell or smoke occurs immediately turn off the main unit s power unplug the power cord and consult your nearest JVC dealer Never use digital equipment such as portable telephones or video cameras when using this unit as this may cause a malfunction Handling precautions For extended product life avoid using and storing the unit in places subject to the following conditions extreme heat or cold vibrations dust or soil high humidity strong noise source The environmental temperature under which this unit can be operated is limited by the image sensing device Use this unit within a
19. ect the optional endoscope adapter DZ E3U or DZ E33U to lens mount of camera head Remove the cap from the lens mount when cap is con nected to the lens mount align the screws of lens mount and endoscope adapter and turn the lens mount clockwise to tighten it Adapter Endoscope T To Camera control unit 3 When the equipment is purchased it is not yet sterilized Endoscope adapter camera head and cable have to be sterilized at the hospital before use For the method and condition of sterilization refer to page 6 4 The lens of the endoscope adapter may get clouded with moisture due to the difference in the external and internal temperature humidity When this happens sterilize and remove the moisture collected at the lens of the endoscope adapter with a sterile swab Pale vertical streaks appear in the picture Monitor Screen High intensity subject electric light lamp the sunlight etc The following CCD related phenomena may appear on the view screen during shooting These are caused by the CCD and are not malfunctions Smear Phenomenon Occurs when a luminescent subject is captured Line Distortion Striped patterns or lines appear as jagged patterns White or colored luminescent spot When this unit is operated for a long time under high temperature a white or colored luminescent spot may appear on the screen In this case itis necessary to lower the environmental operating
20. een exposed to rain or water d When the product fails to work normally e If the product has been dropped or damaged in any way f When the product exhibits a distinct change in performance this indicates a need for service 3 Operational Life of the Product Regular maintenance and inspection is essential for ensuring safe and long lasting operation of this product Inspect and maintain the product before and after use Also please be sure to request a qualified service personnel to check the product at least once a year STERILIZATION The camera head with camera cable and endoscope adapter can be sterilized with ethylene oxide EO EO gas parameters are as follows Ethylene oxide gas 10 96 EO and 90 Inert gases Temperature 40 C to 60 C 104 F to 140 F EO gas intensity 600mg L Sterilization time 2 to 4 hours Desorption Aeration Aerator 50 and more than 18 hours In room temperature it is required more than 48 H Notes Always follow the recommended procedure from the manufacturer of your EO sterilization system when sterilizing the DZ VCA3U camera head with cable and adapter Never sterilize camera head without connecting endoscope adapter and connector cap Deterioration of camera cable Due to ethylene oxide rubber part of camera cable may cause deterioration Depending on the frequency of use however at least once a year an expert must check the device When connecting th
21. eptacles and the point where they exit from the product For the safe use of this equipment be absolutely sure to follow the guidelines below 1 Leave installation of the Mobile Video Cart and the unit to a specially trained service persons 2 Be absolutely sure to use the optionally sold AA V31U isolation transformer The specifications for the AA V31U is given on page 22 3 There are openings in the equipment Fire or electric shock may result if liquid splashes inside one of these openings To prevent any possible problems please set the cart in a reasonable position and use carefully Cart information 1 Cart should meet with UL2601 1 2 Load capacity Top Please chose a video cart which maximum load capacity is more than 45 kg 3 Two casters have brakes When using a mobile cart in OR the two of the four brakes should be set for safety after setting the position of the cart 4 Important notice 1 When using mobile video cart in OR precautions to avoid crossing over the power cord of the cart When using a mobile cart in OR precaution to avoid power cord of the cart to be caught by foot or caster of the cart should be taken 5 Important notice 2 When mounting monitor on a mobile cart we strongly recommend the use of monitor strap for Monitor Strap An example of using medical video cart e Do not use mobile cart when crossing a threshold or excessively thick carpet Beextra carefu
22. ing device E Shooting system E Color separation optical system E Number of effective pixels Camera output Lens mount E Dimensions E Weight E Classification Camera control unit section E Number of scanning lines Scanning system E Scanning frequency Aspect ratio Vertical resolution center S N Sensitivity Sync system External sync signal input Color bar Contour correction E Electronic shutter speed E Video output SXGA signal HD signal NTSC signal DV signal Camera input Date indication Time indication Rating Classification of insulation Operating environment Storage environment Dimensions Weight Accessories Horizontal resolution center Minimum subject illuminance 1 3 inch PS CCD 350 000 pixels 9 CCD system 1 3 inch F1 4 3 color separation prism 659 horizontal x 494 vertical 330 000 pixels approximately 19 pins Standard C mount flange back 17 526 mm in air Camera head 44 W x 51 4 H x 57 7 D mm 1 6 8 x 2 1 16 x 2 2 8 not including protrusion and camera cable etc Camera head 100 g 0 22 Ibs Type CF applied part 1125 980 effective 2 1 interlace HD output NTSC output Progressive SXGA output HD OUT 33 71625kHz horizontal 59 94 Hz vertical SXGA OUT 67 4325kHz horizontal 59 94 Hz vertical NTSC OUT 15 73425kHz horizontal 59 94 Hz vertical 14 3 750 TV lines TYP HD Y output
23. ing the opera tion of this product while it is being employed as an endoscopy system during surgery etc take the appropriate action as described below W Problem with the endoscope The lamp for the light source may have been burned out Please read the operating manual for details on replacing the lamp W Problem with the Micro HD Camera If a problem with the operation of the monitor Screen develops and the normal screen is no longer displayed turn the power off and then turn the power back on again after 5 seconds later W After use immediately remove the camera cable from the CCU and connect the cap to the connec tor Align the cap to the connector and turn the cap clockwise to connect it firmly E Check the following items before using the product 1 Make sure that the product is grounded properly 2 Make sure that all of the cords are connected properly 3 When using this product in conjunction with other equipment consult a specialist in order to minimize any risk of misoperation or misdiagnosis 4 Make sure that the product has been sterilized Pay attention to the following while using the product 1 Make sure that the patient is not experiencing any distress 2 Make sure that all of the equipment is operating correctly 3 Make sure that the patient does not touch the product Pay attention to the following after using the product 1 Following the prescribed procedure return the produc
24. l when transporting this product with mobile cart Sudden stops excessive force and travelling on uneven surfaces may cause the product and cart to topple Safety precautions Please Read Before Use WARNING This MICRO HD CAMERA should be used with a power supply of AC 120 V v 60 Hz only To prevent electric shocks and fire hazards DO NOT use any other power supply WARNING This camera head with camera cable and camera control unit are not sterilized Before using please conduct the sterilization according to page 6 WARNING Use the endoscope in accordance with IEC60601 1 and IEC60601 2 18 WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN THE CABINET WARNING The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced level of safety with the resulting system Consideration relating to the choice of accessories shall include use of the accessory in the vicinity of the patient evidence that the safety of the accessory has been certified in accordance with the appropriate IEC 60601 1 and or IEC 60601 1 1 harmonized national standard WARNING The Monitor and VCR must be con nected to the Isolation Transformer which power supply is AC 120 V of a hospital wall outlet To prevent electric shock and fire hazard DO NOT plug directly into a hospital wall outlet WARNING In order to avoid the risk of fire and sho
25. n environmental temperature range of from 5 to 35 C 41 F to 95 F Avoid strong vibrations or violent shocks to this unit during installation or transportation If the power voltage is too high or too low the service life of this unit may be decreased and optimum performance may not be assured Do not plug in or unplug the camera cable connector while this unit turned on Doing so could cause a malfunction Wipe the cabinet clean with a soft cloth To remove excessive dirt clean the unit with a soft cloth dipped in a mild detergent diluted with water Wring out any excess liquid before wiping Use a dry cloth to dry the unit Do not use a volatile liquid such as benzene thinner or alcohol These may damage the cabinet surface or the coating Be sure to use this unit in combination with the compo nents described in Micro HD camera system component on page 9 Do not use this unit near strong radio sources such as a radio TV or portable phone or near devices that produce a strong electromagnetic field such as a trans former or motor as this may generate noise in the picture or cause changes in image colour Do not bring an electronic scalpel or other sources of electronic noise near this product Doing so can interfere with the monitor display When using a wireless microphone and receiver with this unit check them beforehand to ensure that noise does not enter the wireless receiver If a problem develops concern
26. r equipments to the isolation transformer AA V31U 3 Switch on isolation transformer AA V31U power switch 4 Switch on DZ VCA3U power 5 Switch on W VHS power Insert W VHS tape and make sure that it can record 6 Switch on the power of monitor Check that picture taken by camera can be displayed on the monitor 7 Operate each device according to its operating procedure Note Consult JVC service personnel or authorized dealer when connecting the system for the first time Do not disconnect or modify the connection by yourself Connector Camera cable connector input output terminals CCU side Sync signal output Sync signal output Shutter speed control signal Shutter speed control signal Shutter speed control signal Control signal input DC 15V output DC 5V output 9 GND 10 7 5V output 11 B signal input 12 GND 13 G signal input 14 GND 15 R signal input 16 GND 17 Basic clock input 18 GND 19 NC gt Symbols indicated on this equipment have the following meanings Attention consult ACCOMPANYING DOCUMENTS Equipotentiality Alternating current D Protective earth ground On power connection to the mains Off power disconnection from the mains Earth ground Im TYPE OF APPLIED CF EQUIPMENT Specifications Design and specifications subject to change without notice MICRO HD CAMERA DZ VCA3U Camera head section E Image sens
27. siseses tgeen 14 Menu control section ences 14 Basic operation eiie orina nans cuni ronda i ana orna 17 White balance adjustment auto 17 White balance adjustment manual 17 Operation of Micro HD camera 18 System operation sese 18 e 19 Specifications 20 Optional Equipments eere 22 Technical and service assistance 22 Warranty and after sales service 23 Warranty record confirmation and safekeeping 23 Standard construction Please check the following accessories before use Camera head AC Inlet cable Camera control unit Feature Thank you for purchasing the DZ VCA3U MICRO HD CAMERA Compact lightweight design Thanks to the incorporation of 1 3 inch CCDs the camera head s outer dimensions have been reduced to a compact 44 W x 51 4 H x 57 7 D mm and its weight to only 100g High resolution A total of three VGA 1 3 inch CCDs are used for each R G and B With digital signal processing this camera is able to produce extremely high horizontal resolution 750 TV lines and vertical
28. sure your personal safety In order not to defeat the built in safeguards observe the following basic rules for its installation use and servic ing ATTENTION Follow and obey all warnings and instructions marked on your product and its operating instructions For your safety please read all the safety and operating instruc tions before you operate this product and keep this booklet for future reference Dear Customer Thank you for purchasing the MICRO HD CAMERA Before use please read the safety information and precautions contained in the following pages to ensure safe use of your new MICRO HD CAMERA Importer s name amp address J P C JVC PROFESSIONAL PRODUCTS COMPANY 1700 Valley Road Wayne NJ 07470 TEL 973 317 5000 FAX 973 317 5030 Precautions on installing medical electrical equipment Safety and hazard prevention For the safe use of this equipment always follow the guidelines described below Power connection 1 To prevent damage to the product make sure that it is grounded properly and pay attention to its power polariza tion 2 Overloading Do not overload wall outlets extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock 3 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience rec
29. t to its original state before it was used and then turn the power off 2 When disconnecting the cords do not pull on the cords with undue force 3 Storage location Avoid locations where the product may get wet Avoid locations with extremes in air pressure tempera ture or humidity poor ventilation exposure to direct sunlight high levels of dust high levels of chlorine or sulfur compounds Avoid storing the product on an unstable surface for example one that is on a slope or is exposed to vibra tion or physical shocks Avoid storing the product in a location that is used to store chemicals or where gases are present Clean the product its accessories and the cords so that they are ready for use the next time that they are needed If the product malfunctions do not attempt to repair it yourself Place a label on it that clearly indicates that it is out of order and contact a repair specialist Do not attempt to modify the product Equipment not suitable for use in the presence of a flammable anaesthetic mixture with air or oxygen or nitrous oxide Precautions Continued Inspection and maintenance Phenomena peculiar to CCDs The product and its components must be inspected regularly by a specialist The product should be inspected once a year Camera Head Section 1 Leave installation of the product to a specially trained service personnel 2 Conn