Home
Jacuzzi SEDONA Outdoor Shower User Manual
Contents
1. 18 5 8 STEAM HEAD AND SHIELD PRE INSTALLED AND CONNECTED TO STEAM GENERATOR SERVICE LEFT HAND UNIT SHOWN ACCESS SIDE VIEW Framing Support The drain extends below the bottom of the base Note that this requires a cutout in the floor The floor structure beneath the base must be able to support a total weight of base and bather The unit must be supported from the bottom of the base and not from the tile flange Ifthe subfloor is level no other preparation is necessary You can proceed to install the base If the subfloor is not level you MUST level the entire surface prior to installing the base The use of materials that shim or provide a level installation are allowed provided the method used will ensure a level base that is supported from the bottom Materials that may be used are a floor leveling compound mortar plaster or minimal expansion structural foam having a minimum density of 5 Ibs cubic ft however the base must remain level in order for it to drain properly and the foam feet must make full contact with the leveling material Both sides of a joint or splice of subfloor should be level to each other When attaching the base flanges to stud wall use shims to fill any gaps between the tile flange and studs The shower base should be installed after construction of the studwall and after rough plumbing is in place using the self drilling screws provided with your unit It is important that the framed pocket be pl
2. 13 PRODUCT SPECIFICATIONS ARE SUBJECT CHANGE WITHOUT NOTICE USE INSTALLATION INSTRUCTIONS SUPPLIED WITH PRODUCT Jacuzzi Whirlpool Shower base has obtained applicable code standards listings generally available on a national basis for products of this type It is the responsibility of the installer owner to determine specific local code compliance prior to installation ofthe product Jacuzzi Whirlpool Shower base makes no representation or warranty regarding and will not be responsible for any code compliance JACUZZI WHIRLPOOL BATH Jacuzzi Whirlpool Bath National Headquarters P O Drawer J Walnut Creek CA 94596 925 938 7070 Service Support Call 800 288 4002 2002 Jacuzzi Whirlpool Bath T87100B 2 04 9 Printed Recycled Paper Printed in the U S A 14 Jacuzzi Whirlpool Bath Limited Warranty Steam Generator Products Jacuzzi Whirlpool Bath warrants that its Steam Generators warranted products are free of manufacturing defects both as to workmanship and material for 5 years andit will replace or repair defective parts or equipment for the period of time and in accordance with the conditions set forth below The terms of the warranty will be administered by Saunatec Inc dba AMEREC 1 Applicability This warranty applies when the warranted product a is installed in accordance with installation instructions provided b is properly and reasonably maintained and c has not been subjected to
3. SteamPro Drain Down Configurations Digital Control amp Temperature Sensor Rough in Drain Information Plumbing and Water Supply Electrical Connections Digital Controller Mounting Temperature Sensor Mounting Flange Mounting Finish Materials O O A N Iv 55 c O Operation e Maintenance Troubleshooting 11 12 SteamPro Wiring Diagram 13 SteamPro Warranty 15 16 Base Warranty 17 18 Save These Instructions for Future Use Owner s Record Date Purchased Purchased From Installed By Serial Number Base Serial Number Steam Generator Model Important Read complete instructions before beginning installation Each shower base is shipped with a drain and stainless steel strainer Remove the shower base from the carton Do not destroy the shipping carton until after satisfactory inspection of the product Immediately upon receipt inspect the base before installing Should inspection reveal any damage or defect in the finish do not install the base Damage or defect to the finish claimed after the base is installed is excluded from the warranty Jacuzzi Whirlpool Bath s responsibility for shipping damage ceases upon delivery of the products in good order to the carrier Refer any claims for damage to the carrier For definitions of warranty coverage and limitations
4. 8 22 5 Us CE 822 Sas S gt So 5 329 gx 3 joe 7 AKO T7 70777777 24 A PILA T 909 Ss SE RR RM RSR 0205 6 0090 gt 5 gor F 5525 zs 55 20850 88822 558 2 2 8 928 2 4 22 gt gt 2 88358 fte 5 no HD E PEE HOG URRR EEA E 2 gQcoog o0 m gt Fa 3 m 6 2566 6 o 6 an 5 o 935 Ea lt 5 gt 585 2 099 52 92255 83425 960 05 23 g osc 9 3 Oo 58822989 00 55 50 Data Vs oo 2 099240846 058 a gt 2059 rE ES a 2 ge S 8439 coook 905075 GO 3 88657 DZ 2852555 5 5 04 lt 9 852 lt dm lt lt 5888 BENVKE 5 78 5 585243 8 83 565 25225 e d 29099 Booot 5835 88 3922 3 SZ amp 8 562 3505 525555209 S2 Meme oO o 90 59 peo 2 3 3 289 82233 oS putea se 8208 o 5256 5852042 SE N U9ioo 895602 gt 282 aa Sade 90 i23 Zo L 1 mS 90 dj 39 9 B 59 2355 amp 9 609go 99 025 gy as a agree SS g 27921 sz239g9 89 38755 284 4936 4 9 2 2 S gsal 358 3 255 8 55209 5 0 3 o gt 26 8 2 8 8283 5 2530 T 522098605 gg 9 8
5. SEDONA Steam amp Shower Base INSTALLATION OPERATING INSTRUCTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTALLATION INSTRUCTIONS Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body s ability to regulate its internal temperature hyperthermia Consult your physician about your safety and comfort before using the steam system Limit your use of steam to 10 15 minutes until you are certain of your body s reaction A cooling shower spray can be used simultaneously with the steam to assist in regulating your body temperature Alcohol and certain drugs or medications such as tranquilizers affect a person s ability to withstand high temperatures and may produce dangerous side effects Don t use alcohol or drugs when using steam The elderly the infirm and children should not use the steamer unattended Pregnant women and people with heart conditions should consult their physicians before using the steamer The wet surfaces of steam enclosures can be slippery Use care when entering and exiting Do not place or use electrically connected devices such as television radio or stereo speakers lights hair dryers or telephones within 1 5 m 5 feet of a steam enclosure shower or bath Read and follow manufacturer s safety information with all optional equipment The steam head
6. Itis best to tape the sensor and cable connection together to avoid disconnection inside the wall Apply silicon caulk as shown in diagram and insert the sensor in the hole An optional trim ring is included with the sensor If the 7 8 hole is jagged or is cuttoo large the trim ring may be used to cover the exposed edges Make sure that the sensor probe is pointing down once installed Tape the sensor in place while the silicone hardens SILICONE WALLS Pe SEALANT PROBE MUST BIETAN DOWNWARD OPTIONAL TRIM RING 7 8 HOLE Flange Mounting After base is in position secure flange to studs with screws provided If there is gap between flange and stud shims MUST be used TYPICAL FLANGE MOUNTING DETAIL STUD FLANGE ATTACH WITH SCREWS L PROVIDED Pa STUD SHIM IF NECESSARY TO FILL GAPS BETWEEN STUD AND FLANGE Finish Materials Apply tile or other finishing material leaving a 1 8 gap between the finishing material and the base flange lip Seal this gap with silicone sealant Leave a minimum 1 4 weep hole at the back and front corners of the base The weep holes are necessary to allow drainage from leakage through unsealed tiled grout Filling the area marked DO NOT FILL will prevent moisture from draining back into the base through the weep holes This moisture is due to leakage through the tile grout Sealing the t
7. b Replace call Service Department 3 Replace the PCA printed circuit assembly call Service Department Check that the blue wire is properly attached to the water level probe Check that the generator is properly grounded Check the green ground wires to the PCA printed circuit assembly Replace the PCA printed circuit assembly Service Department awh E Check for proper water supply Supply valve on Check for closed drain valve 2 Remove the blue wire from the level probe tf the unit fills clean or replace the level probe 3 Reconnect the shortest wire to the level probe At the water valve solenoid slide back the blue connector enough to get the voltmeter probes on the solenoid terminals Measure the voltage across the solenoid terminals If it is not 208V 240V replace the printed circuit assembly If 208V 240V is found proceed with steps 4 amp 5 4 Remove water solenoid valve disassemble clean reassemble and check for proper operation 5 Replace the water solenoid vaive call Service Department 1 a Make sure 25 minutes has elasped b Disconnect drain valve wires if drain valve opens replace PCA 2 a Disassemble drain vaive and clean b Clean tank using deliming solution 11 SYMPTOMS Control ON Control light Unit won t steam Note Steam lit Steadily or Time Temp properly displayed on Digital Display Control ON Digital Control displays
8. refer to the published warranty information packaged with the product Jacuzzi Whirlpool Bath is not responsible for any defect that could have been discovered repaired or avoided by following this inspection and testing procedure Plan the installation in relation to the finished wall surfaces Take into account the dimensions of both the shower base and the shower door enclosure to be used with it NOTE Damage or defects which could have been discovered and repaired prior to installation and which are claimed after final installation of the product are excluded from our warranty SPECIFICATIONS TOTAL WEIGHT PRODUCT DIMENSIONS FLOOR LOADING WEIGHT ELECTRICAL 60 1524 mm L 310 Ibs 110 Ib 230 VAC 60 Hz 32 813 mm W 141 kg 50 kg 40 AMP 3 Wire 18 5 8 473 23 Ib sq ft Requires a 112 kg sq m Dedicated Separate Circuit SteamPro supplied with NEMA 6 50P plug NEMA 6 50R receptacle required Product specifications are subject to change without notice LOCATION FOR ud d INCOMING WATER SUPPLY LINE STEAMER INSTALLED AND PREPLUMBED WITH 3 8 COPPER RECEPTACLE LOCATION RECEPTACLE TO BE ACCESSIBLE FROM TUBINGTO STEAM 32 SERVICE ACCESS GENERATOR WITH Fico SHUT OFF VALVE 16 SUM sn 73 SHUT OFF I VALVE pu k 45 3 8 TOP VIEW 1 TILE FLANGE
9. without limitation any of the following careless handling lifting unit by plumbing abrading finish etc including its own negligence modification of any type for any reason including modification to meet local codes improper installation including installation not in accordance with instructions and specifications provided with the unit connections supplied by the installer of the equipment improper voltage supply or unauthorized electrical modification misuse incorrect operation or lack of proper routine maintenance operation of the unit without specified minimum amount of water or at inappropriate water temperature use of abrasive or improper cleaners or acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet ceiling loss of use etc including its own negligence damages to respecting or resulting from plated parts when pool and or spa chemicals are used in the unit optional bath equipment not manufactured by the Company supplied by Dealer installer or the Company the unit s prior usage as an operational display or defects that should have been discovered before installation This limited warranty does not include labor transportation or other costs incurred in the removal and or reinstallation of the original unit and or installation of a replacement unit any costs relating
10. City St Zip Phone Purchaser s Signature Model No amp Serial No Jacuzzi Whirlpool Bath Limited Warranty Builder Group Bath Product WARRANTY COVERAGE Jacuzzi Whirlpool Bath the Company offers the following express limited warranty to the original purchaser of any Jacuzzi Whirlpool Bath Builder Group Bath Product unit who purchases the product for personal or single family use user The Company will repair or replace at its option the unit or its equipment in accordance with the following terms and conditions ONE YEAR LIMITED WARRANTY ON BATHS Our warranty on Builder Group Bath products is for one 1 year Our warranty covers the unit and factory installed components e g pump motor against defects in material or workmanship Warranty coverage begins on the date the unit was originally purchased by the user NINETY DAY PARTS ONLY LIMITED WARRANTY ON OPTIONS AND ACCESSORIES Our warranty on options and accessories manufactured by the Company is for ninety 90 days for parts only Our warranty covers options and accessories manufactured by the Company e g fill spout kits trim kits skirts against defects of material or workmanship Warranty coverage begins on the date the option or accessory was originally purchased by the user WARRANTY LIMITATIONS Our warranty does not cover defects damage or failure caused by the common carrier installer user or other person or resulting from
11. E001 Control ON Digital Control displays E002 Control ON Digital Control displays E003 Control ON Digital Control displays gt gt gt Control STEAM LED light blinking Control won t tum OFF Control light off Control OFF Unit won t shut off Water continually sputters out of steam head Unable to adjust Time or Temp setting with Digital Control Troubleshooting PROBABLE CAUSES Unit has not filled completely Heating elements burnt out Level probe faulty PCA printed circuit assembly is fauity Temperature sensor not connected Temperature sensor or cable shorted Control improperly connected Steambath temperature over 132 Sensor cable faulty Control improperly connected Sensor cable faulty Control faulty Control is faulty PCA printed circuit assembly is faulty Foaming contaminants in the water Control fauity PCA printed circuit assembly is faulty ACTION TO BE TAKEN 1 a Push the control OFF b Open the drain valve allowing tank to drain completely C Close the drain valve d Push the control ON e Unit will begin filling listen for a click noise Within 20 seconds after Click noise is heard the water fill will shut off This will indicate the tank is full Go to step 3 if the tank does not fill See SYMPTOMS Unit won t fill up 2 If the tank filled but the relay click was not heard temporarily ground t
12. a NEMA 6 50R receptacle to the studwall at least 4 inches above the floor The receptacle is not provided LOCATE RECEPTACLE IN THIS AREA RECPTACLE TO BE ACCESSIBLE FROM SERVICE ACCESS Controller Mounting Finished Wall Mounting The low voltage control can be mounted directly to a finished wall either inside or outside the steam room Using a 2 hole saw drill a hole in the finished wall where the control is to be mounted the control cable should already be roughed in to this location Locate the control cable pull it out through the 2 hole and plug it into the connector on the back of the control housing With the decorative cover removed screw the two 3 control housing mounting screws 1 4 into the mounting bracket See diagram Run a bead of 100 silicon caulk in between the 2 ridges around the perimeter on the back of the control housing See diagram Insert the mounting bracket into the wall cavity by first pushing with the control housing and then with a hard flat surface on the control housing mounting screws which extend out through the control face Once the mounting bracket has been inserted into the finished wall center the control and tighten the mounting screws to draw the control housing securely against the finished wall Do not over tighten the mounting screws Install the decorative cover plate by sliding the top of the cover plate over the tab on the top of the control h
13. call Service Department 2 Treat as E002 fault above 1 Check that the control cable is properly plugged in at the control and at the generator Connect Control to primary SK1 connector on the PCA Tum off power supply wait one 1 minute then tum back on Check for proper operation If STEAM is stil blinking turn off power supply and Service Department 2 Check sensor cable as with Digital E001 and E002 3 Replace Control call Service Department 1 Replace the control call Service Department 1 Tum off the power to the generator replace printed circuit assembly call Service Department 1 Flush tank 3 times See section 8 flushing procedure 2 Service Department 1 Replace control call Service Department 2 Replace PCA call Service Department 12 Wiring Diagram 2 LATI INNSSNSNNNNSNNSSSSSSSSNSNNNNNNNSSSSSSSSNNSNNNNSNSNSESNNNNNSNSSSSSSNSNSNNSNNNV UC 2 SS SS 22 ONOFF ii N 7 4 240 OPTIONAL AUTOMATIC DRAIN up 273 E ied Dmm pr oq IE 1 EN HL n erau 0 2222222222222222222222222222222222227 J2 al STEAM TEMPERATURE GENERATOR dT SENSOR STEAM ROOM H ORANGE 30 MINUTE TEMP WIRES OR DIGITAL CONTROL OPTIONAL Bi Ls SECOND DIGITAL 9 2 CONTROL en ee j 7 TANK FRONT
14. damage misuse or abuse 2 Registration This warranty becomes valid only after the Limited Warranty Registration form provided with this warranty is completely filled in and signed by the original purchaser and mailed to AMEREC within sixty 60 days from the date of original installation This warranty is nontransferable and shall extend only to the original purchaser 3 Duration of Warranty AMEREC or it s authorized representative will provide parts to replace those with manufacturing or workmanship defects for a period of five 5 years from the date of original installation except when the warranted product is installed in commercial locations such as clubs condominiums apartments spas or military facilities In commercial locations AMEREC or its authorized representative will provide parts to replace those with manufacturing or workmanship defects for a period of one 1 year from the date of original installation Additionally for noncommercial locations in the United States AMEREC or its authorized representative will provide reasonable labor to replace defective parts for a period of two 2 years from the date of original installation and three 3 additional years if the product is returned to the factory 4 Warranty Work All warranty work must be a authorized by AMEREC before it is performed and b performed only by authorized AMEREC representatives This warranty shall not apply to any charges for parts or labor incurred b
15. o 9 ES ue Paes 5 Sosea Va 3 saibe Sc 2 3 C _ wee 85 5 2552 3a o08 EEEE 2 B o Bes Sa e o 228296 ss lt 5339 8988 82 9555 99090 S 029 S gas 98882 dvgg 5 958 cal 829 852 SN 85 g 25 288823 F238 55 02 2 o em G 59 Bn Ss N vI GNZZG 2853 8 gt gt 3286 gt 5 98 E Po SOO 565 85059 0 5 8 o No a 2v 2 22565 2 S 9x382 S 5 5 8 58 52 50 0 2935 3 Su 3 al 5 5 90 o 38 e 0 5 2 lt 25 25 ae 8 2025 es Qs 23 3 3 5 9 3 Ox e 0 Qn 4 2 Face 88 2 8 saga 87 g 223 52285 5 5 2888 d 52 58 2 5 555 55 52 9 58 a ea 2 m Sa 8 S Ds 52 gog 9 5 gt o9 9 9 zo 4 6 g 2 2 sa 8 Bes 22 fe 2 e o B 8 55 5 ze g 0 lt o 8 so gt E 8 8 D o 29 9 8 zi a 3 55 89 Q
16. to obtaining access for repair or loss of use damage including loss of sales profit or business advantage of any kind under any circumstances Bath units in commercial use are excluded from any warranty coverage if any addition deletion or modification of any kind whatsoever has been made to the unit or to any component Warranty coverage is provided in the United States of America and Canada IMPLIED WARRANTIES Implied warranties of merchantability and fitness for a particular purpose are disclaimed altogether or to the full extent allowed by law NOTICE This warranty gives you specific legal rights and you may also have other rights which vary from state to state There are no warranties applicable to Jacuzzi Whirlpool Bath products except as expressly stated herein or as implied by applicable state and federal laws The Company will not be responsible for any statements or representations made in any form that go beyond are broader than or are inconsistent with any authorized literature or specifications furnished by the Company Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you RETURN OF WARRANTY CARD The attached Warranty Registration Card MUST be filled out by the purchaser within thirty 30 days from purchase and mailed to Jacuzzi Whirlpool Bath in order for this warranty to beco
17. ble to the purchaser Under no circumstances shall Jacuzzi Whirlpool Bath be liable by virtue of this warranty or otherwise for any special indirect secondary incidental or consequential damage of any nature to any person or property arising directly or indirectly out of the use or inability to use a warranted product Some States do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you 8 Disputes Any lawsuit alleging breach of this limited warranty shall be commenced within one year from the date of breach In addition any such lawsuit may be commenced only in King County Washington This warranty gives you specific legal rights and you may also have other rights which vary from State to State LIMITED WARRANTY REGISTRATION FORM Please fill out and return within 60 days of installation to Box 2258 Woodinville WA 98072 The undersigned hereby acknowledges the receipt of Jacuzzi Whirlpool Bath Limited Warranty and affirms that the date of installation was 20 further that installation of the equipment has been completed according to the Jacuzzi Whirlpool Bath installation instructions furnished with the equipment and that I have read understand and agree to the conditions and terms of the Jacuzzi Whirlpool Bath Limited Warranty in its entirety Name of Purchaser Address
18. e Temperature Sensor Rough in It is recommended that the sensor be mounted in the steam room 6 from the ceiling or below bottom of dome but not directly over the steam dispersion head or more than 7 feet above the floor String the sensor cable from the sensor location through 1 2 holes in the wall studs or ceiling joists to the generator location Leave 12 of slack at the sensor location Note Do not staple through or damage cable Leave a couple of feet of sensor and control cable free behind the steam generator to allow for removal through access panel for maintenance or servicing if necessary WATER SUPPLY TO MANUAL WATER TEMPERATURE SUPPLY SHUTOFF SENSOR VALVE PROVIDED UE eerie t NTROLLER 22 TO STEAM HEAD STEAM OUTPUT FACTORY INSTALLED PRESSURE RELIEF VALVE 3 4 NPT PROVIDED REDUCTION FROM 3 4 NPT C TO 1 2 NPT PERMITTED 8 NOTE PRESSURE RELIEF DRAIN LINE DRAIN LOCATION AND METHOD AS REQUIRED BY LOCAL CODES TO BE 1 2 INCH MINIMUM SIZE COPPER TANK DRAIN DOWN MANUAL VALVE PROVIDED NOTE SITE DRAIN OR OTHER METHOD AS REQUIRED BY LOCAL CODES WITH AUTOMATIC DRAIN OPTION WATER DISCHARGED IS LESS THAN 140 F OPTIONAL AUTOMATIC DRAIN VALVE NOTE ALL COPPER PIPE SIZES ARE TO BE INDUSTRY NOMINAL SIZES AND FITTINGS ARE NOT PROVIDED UNLESS OTHERWISE NOTED Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic opera
19. efore receiving approval by AMEREC 5 Return Authorization Number A return authorization number assigned by an AMEREC representative must accompany all returned parts Parts which are returned without a return authorization number may not be repaired or replaced 2 Jacuzzi Whirlpool Bath C O AMEREC P O Box 2258 Woodinville WA 98072 6 Procedure Requests for repair or replacement a return authorization number or warranty information should be directed to AMEREC by calling toll free 1 800 363 0251 or by writing to AMEREC 17683 128th Place Woodinville WA 98072 Defective product or parts returned for repair or replacement must be shipped prepaid to AMEREC at the above address Shipping costs for return of replacement product or parts to the purchaser will be at the expense of the purchaser 7 Limitations Exclusions and Remedies There are no warranties which extend beyond the descriptions on the face hereof This limited warranty is in lieu of all warranties expressed or implied and of all other obligations or liabilities on the part of Jacuzzi Whirlpool Bath There shall be no implied warranty of merchantability Jacuzzi Whirlpool Bath neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the sale of its products Damages for breach of this warranty shall not exceed the lesser of the cost of repair or replacement Repair or replacement shall be the exclusive remedy availa
20. h warranty of this product Slide the shower base into the framed opening and attach the shower base flange to the stud wall and blocking with screws provided NOTE If there is any gap between base flange and stud or blocking shims MUST be used to prevent distortion or cracking of the flange DRAIN ASSEMBLY STRAINER APPLY SER LUBRICANT DRAIN SILICONE ASSEMBLY SEALANT pe SHOWER RUBBER WASHER FIBER WASHER NUT With a large screwdriver and the tool included with the drain tighten the inside compression nut to seal the drain pipe connection After drain is fully installed test for proper drainage If the shower base does not drain properly rectify this condition before proceeding with theinstallation Jacuzzi Whirlpool Bath is notrespon sible for removal and or reinstallation costs TIGHTEN SEALING NUT ln INCLUDED Water Supply Consult local authorities for plumbing code require ments in your area Connect house cold water supply to steam generator supply tubing IMPORTANT Jacuzzi Whirlpool Bath does not warrant connections of water supply fittings and piping or drain systems Nor is it responsible for damage to the shower base which occurs during any installation procedure WATER SUPPLY 3 8 COPPER TUBING SHUT OFF VALVE Electrical Connections A separate circuit is required Install
21. he two long probes If the click is heard as each probe is grounded replace the level probe ff the click is not heard replace the PCA printed circuit assembly 3 After it has been determined that the tank has filled and the click noise was heard remove the heating element access panel Using a voltmeter check the voltage between the two wires on each heating element the voltage should be 208V 240V if proper voltage is found call the factory for replacment heating elements If no voltage is found check wiring diagram call Senice Deparment 1 Check that the sensor cable is connected to J4 on the PCA printed circuit assembly 2 Check the cable connection to the temperature sensor 3 Replace sensor and or cable call Service Department 1 Check sensor cable for damage from nail staple puncture 2 Check sensor cable ends for frayed exposed wire strands 3 Replace sensor and or cable call Service Department 1 Check that the control cable is properly plugged in at the control and at the generator Digital Control to primary SK3 connector on the PCA Tum off power supply wait one 1 minute then tum back on Check for proper operation If E003 is still displayed tum off power supply remove control cable and plug into secondary SK4 connector Tum on power supply and check for proper operation If E003 is stii displayed tum off power and call Department 1 ff bath is too hot shut off circuit breaker and
22. ile grout will prevent this leakage FRONT WEEP HOLE SILICONE SEALANT 1 4 MINIMUM WEEP HOLE REAR WEEP HOLE TILE 1 4 MINIMUM WEEP HOLE SILICONE SEALANT Note The combined thickness of the or other finish material adhesive and cement board must not exceed the edge of the vertical wall on the drain side This condition will not allow the wall jamb of the steam enclosure to sit flat against the vertical wall FINISH NC ENSE TILE FLUSH WITH VERTICAL WALL d Service Access Service access is through the removable panel To remove panel grab the middle of the panel and bow outwards till clips disengage SERVICE ACCESS PANEL GRAB PANEL MIDDLE AND BOW OUTWARDS To reinstall the panel hold at an angle to the skirt and insert clip under edge of skirt opening Bow the panel outward and insert clip on other side If there is a gap between the finish surface and the vertical wall a filler piece included with steam enclo sure may be required Gap must not exceed 3 16 Silicone sealant will also be necessary to eliminate any additional gaps that may be present TILE NOT FLUSH WITH 3 16 VERTICAL WALL ACCESS PANEL BOW ACCESS PANEL OUTWARD FROM CENTER SHELL Clean Up Af
23. independent service person or Company representative has been permitted to inspect the unit during regular business hours within a reasonable time after the problem was reported by the user In order to obtain warranty service consult your local telephone book for the location ofthe nearest Jacuzzi Whirlpool Bath Authorized Service Agent Describe the problem and the Authorized Service Agent will inspect the unit and provide the required warranty service If you are unable to contact a Jacuzzi Whirlpool Bath Authorized Service Agent call or write Jacuzzi Whirlpool Bath Warranty Service Department Drawer J Walnut Creek California 94596 Call 800 288 4002 To obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the problem and proof of purchase You will be instructed how to obtain replacements and where to return at your expense the failed component s option s or accessory ies All replacement parts equipment and repairs shall assume the remaining warranty period of the part s replaced The Company s warranty obligation shall be discharged upon tender of replacement or repair The customer s refusal to accept the tender terminates the Company s warranty obligation r q 2002 Jacuzzi Whirlpool Bath T871000B 2 04 c gt E 3
24. ing for water leaks To remove the unit remove the access panel Turn off power to the unit and disengage the power cord Turn the water supply off at the shut off valve and drain the tank if necessary Disconnect all plumbing Cut and discard shipping restraint Remove 2 screws holding mounting bracket to wood plank Slide unit toward front of base and remove The reinstallation is the reverse of the removal procedure Itis not necessary to replace the shipping restraint SHIPPING RESTRAINT WATER SUPPLY SHUT OFF VALVE MOUNTING BRACKET TO STEAM HEAD REMOVE SCREWS DRAIN DOWN 10 Troubleshooting There are no user serviceable parts in the Generator All repair should be performed by a qualified service person For additional assistance or the factory authorized service person nearest you call the Service Department at 1 800 363 0251 This number is only for service for the steam generator The Trouble Shooting Guide below is meant as a general aid only Follow ACTION TO BE TAKEN in order until the problem is resolved SYMPTOMS Control won t turn ON Control light off Control OFF Control light off Water won t shut off and runs out of the steam head Control Control light on Water wont shut off and runs out of the steam head Control ON Control light on Tank drained Unit won t fill Auto Drain Only installations Control turned OFF tank does not drain afte
25. ingle element If the steam room temperature drops more than 5 degrees both elements will automatically engage Operation of Your Digital Time and Temperature Control 1 Be sure the power circuit and water supply to the generator are on 2 Press the ON OFF button on the control until the temperature is displayed 3 The generator should produce steamin 5to 10 minutes and will turn off automatically in 60 minutes or less depending on the set time The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds 4 To change the time setting press and hold the TIME button on the control Continuing to hold the button will cause the time to increase in 5 minute increments from the prior setting At 60 minutes the time setting will scroll backwards to 5 minutes To shut down the generator press the ON OFF button 5 To change the preset temperature setting press and hold the TEMP button on the control While continuing to hold the button the temperature display will increase in 1 degree increments from the prior setting to 125 degrees Fahrenheit At 125 degrees Fahrenheit the temperature setting will decrease in 1 degree increment to the lowest setting 100 degrees Fahrenheit 6 The TIME and TEMP set points are remembered for your next bath unless power to the steam generator is lost Maintenance of the SteamPro Unit Maintenance of the SteamPro includes flushing and visually inspect
26. is hot Do not touch the steam head or the steam within one foot distance of the head or surfaces surrounding the steam head Do not block or obstruct the steam head in any manner Do not store or use flammable liquids near the steam generator Note This is a professional grade product A good knowledge of construction techniques plumbing and electrical installation according to codes are required for proper installation and user satisfaction We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool Bath products Our warranty does not cover improper installation related problems Optional Accessories Steam Enclosure U194865 Chrome Finish with Clear Glass U194866 Brass Finish with Clear Glass U195865 Chrome Finish with Frosted Glass U195866 Brass Finish with Frosted Glass Dome U192000 Digital Controller with Timer and Temperature Sensor 5063829 Bright Brass Chrome Standard with Unit Automatic Drain Down Valve 5066000 Steam Nozzle E203829 Brass Chrome standard and installed on unit Wall Mount Shower Set C994959 White C994829 Bright Brass C994827 Chrome Optica 100 Single Handle Mixer C997959 White C997829 Bright Brass C997827 Chrome e Large Tear Drop Handle for Optica 100 998959 White C998829 Bright Brass C998827 Chrome Bright Brass Strainer A175829 5 Specifications Roughing in Reference Framing and Support Steam Enclosure
27. me effective 7 ZKO Jacuzzi Whirlpool Bath P O Drawer J Walnut Creek CA 94596 9885 RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user They are responsible for ensuring the unit is free of defect or damage Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility In the event of a problem the unit must not be installed The Company is not responsible for failures or damage that could have been discovered repaired or avoided by proper inspection and testing prior to installation Damage occurring in transit is the responsibility of the carrier The user or installer MUST open the crate and inspect the unit for damage when it is delivered If damage is discovered it must be reported immediately to the seller and the carrier in writing and an inspection requested Failure of the carrier to respond should be reported to the seller and the carrier Your freight claims should be filed promptly thereafter It is the responsibility of the installer building contractor or user to provide access for service The Company is not responsible for any costs relating to obtaining access for repair The user shall bear such costs and if appropriate must seek recovery from the installer Damage occurring to the unit during installation is the responsibility of the installer and or building co
28. ns There are several locations left hand unit shown where the optional automatic valve may be located when connecting to a drain line as shown in illustration Right hand unit is mirror image Exact location to be determined by installer The manual drain valve can be moved from its current position when connecting to a drain line To allow steam generator removal for maintenance or service use a straight union STEAM GENERATOR FLOW DIRECTION OPTIONAL AUTOMATIC DRAIN DOWN VALVE DRAIN DOWN OUTLET DRAIN DOWN VALVE THIS LOCATION MAY REQUIRE MOUNTED VERTICALLY CUT OUT IN STUD WALL REQUIRES CUT OUT IN FLOOR Control Temperature Sensor Cable Rough in A rough in wiring kit is provided with unit to allow installer to locate and run wires to the temperature sensor and digital controller before finish walls are installed Control Cable Rough in The low voltage control can be mounted up to 25 feet from the generator either inside or outside the steam room String the 25 cable from the generator through 1 2 holes in the wall studs or ceiling joists to the controller location Note Do not staple through or damage cable An option for tile rooms is to use the 1 gang rough in box provided and install at the desired control mounting location A mounting plate with proper 2 diameter hole is included with the control kit Tile up to the 2 hole in the mounting plat
29. ntractor and damage occurring thereafter is the responsibility of the user Failure of any optional equipment is the sole responsibility of the equipment manufacturer Options and accessories manufactured by the Company are warranted for ninety 90 days from the original date of purchase for parts only The Distributor or Dealer is responsible for knowing local code requirements and notifying the installing contractor and or user of these requirements at the time of purchase The Company is not responsible for costs to modify any product to obtain any code approval such as city county or state building codes in U S A or municipal or provincial codes in Canada WARRANTY SERVICE For the customer s benefit the Company maintains a list of independent service personnel to perform required warranty service repairs Such firms are not agents or representatives of the Company and cannot bind the Company by words or conduct The Company will provide the warranty service described above when the following conditions have been met the failure is of the nature or type covered by the warranty the user has informed an Authorized Jacuzzi Whirlpool Bath Service Agent or Warranty Service Department Representative of the nature of the problem during the warranty period conclusive evidence e g proof of purchase or installation is provided to the foregoing by the user proving that the failure occurred or was discovered within the warranty period an authorized
30. ousing and pushing on the bottom of the cover plate to complete the snap fit CONTROLLER MOUNTING IN FINISHED WALL WALL MOUNTING oe CONTROL HOUSING CONTROL VER Rs CONTROL BEATE bx PLATE CONTROL HOUSING SILICON SEALANT MOUNTING SCREWS Tile Wall Mounting String the 25 cable from the control location through 1 2 holes in wall studs to the generator Do not staple through or damage the cable Use supplied cable only A one gang junction box provided must be installed at the desired location A mounting plate with a 2 hole is included Tile upto the 2 hole in the mounting plate To mountthe control apply silicon sealant between the 2 ridges around the perimeter on the back of the control housing and press control against tile Clean up any excess sealant Connect the cable from the back of the steam generator to the digital controller TILE WALL MOUNTING SINGLE GANG JUNCTION BOX PROVIDED MOUNTING PLATE TILE UP TO 2 HOLE Temperature Sensor Mounting The temperature sensor should be mounted 6 below the ceiling or dome inside the steam room but not directly over the steam dispersion head or more than 7 feet above the floor Using a 7 8 hole saw drill a hole in the finished wall where the sensor is to be mounted the sensor cable should already be roughed in to this location Locate the sensor cable pull itout through the hole and plug it into the temperature sensor
31. r 25 minutes and motorized drain valve stays closed PROBABLE CAUSES Improper power supplied no power Control improperly conntected PCA printed circuit assembly is faulty Control cable is faulty Contol is faulty Water solenoid valve is stuck open PCA printed circuit assembly is faulty printed circuit assembly is faulty Connection between the blue wire and the water level probe is faulty Unit improperly grounded No water supplied tumed off Plugged water solenoid valve Water solenoid valve is faulty PCA printed circuit assembly is faulty Level probe is faulty printed circuit assembly is faulty Drain valve may be clogged with calcium ACTION TO BE TAKEN 1 a Make sure circuit breaker is ON b Using a voltmeter check the voltage across the two fuses on the PCA printed circuit assembly Voltage should be 208V 240V Check fuses on the PCA If fuse s are blown replace with Buss MDL 15 100 or equivalent fuse If the fuse blows again call Service Department Check control s installed per Section 6 5 Replace PCA printed circuit assembly call Service Department Replace control cable call Service Department Replace the control cail Service Department Cid CN Tum off power to the generator If the water stops to step 3 2 a Remove the water solenoid valve dissassemble clean re assemble and check for proper operation
32. ter Installation To avoid dulling and scratching the surface of the shower base never use abrasive cleaners A mild liquid detergent and warm water will clean soiled surfaces Remove spilled plaster with a wood or plastic edge Metal tools will scratch the surface Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge Paint tar or other difficult stains can be removed with paint thinner turpentine or isopropyl alcohol rubbing alcohol Minor scratches which do not penetrate the color finish can be removed by lightly sanding with 600 grit wet dry sandpaper You can restore the glossy finish to the acrylic surface of the shower base with a special compound Meguiar s 10 Mirror Glaze If that is not available use automotive rubbing compound followed by an application of automotive paste wax Major scratches and gouges which penetrate the acrylic surface will require refinishing Ask your Jacuzzi Whirlpool Bath dealer for special instructions Operation The digital control features an adjustable 60 minute time and temperature control with digital display The actual room temperature and time remaining are alternately displayed every 5 seconds The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees Once the set temperature is reached the soft steam feature automatically engages cutting steam production back to a s
33. tion if the tank is not drained regularly Drain the tank frequently Jacuzzi Whirlpool Bath also strongly recommends purchasing and installing the optional automatic drain down valve The tank will be drained automatically after each use after the water temperature lowers Water filters and other conditioners are strongly recommended if the water is of poor quality The Automatic Tank Drain Valve must be installed where the steam generator may be exposed to freezing temperatures e g in seasonal use homes Water supply lines and water solenoid valve must not be allowed to freeze This option prevents standing water from remaining in the tank The tank will be automatically drained through this valve when the water has cooled Read all warranty provisions before selecting a manual drain valve or the automatic drain down option Base Drain Remove the stainless steel strainer from the drain assembly Disassemble the locknut and two gaskets from the back of the drain assembly Apply 1 4 bead of caulking silicone to the drain hole and insert the drain assembly Replace the rubber washer fiber washer and lock nut in that order Hand tighten the locknut Remove excess sealant from finished side Apply a lubricant common household liquid soap works well to the inside of the rubber seal of the drain assembly NOTE Watertight installation of the drain is the installer s responsibility Drain leakage is excluded from the Jacuzzi Whirlpool Bat
34. umb and square and that the framing members be located as detailed in the framing illustration The protective film liner inside the base is used to prevent damage to the finish from shoes tools etc during installation Before installation remove liner to inspect for any defects reapply and do not remove until final cleanup FRAMING AND ROUGH IN DETAILS FOR LEFT HAND UNIT isc MINIMUM 6 FROM FINISHED CEILING IEEE OR BOTTOM OF OPTIONAL DOME TO TEMPERATURE SENSOR LOCATION HEIGHT OF UNIT WITH JACUZZI WHIRLPOOL BATH STEAM ENCLOSURE 83 3 8 1 4 WITH DOME ADD 2 31 4 MAXIMUM 7 FROM FLOOR uil TY 15 3 8 TO DIGITAL 17 7 8 CONTROLLER pos 10 1 2 x 5 33 1 4 LOCATION DRAIN CUT OUT N OU SUB FLOOR H gt lt a 06 FROM STEAM 0 j GENERATOR 60 1 4 SLE S 90 Ty 9s AREA FOR DRAIN OF STEAM GENERATOR WITH MANUAL OR OPTIONAL AUTOMATIC VALVE EXACT LOCATION TO BE DETERMINED BY INSTALLER 2 DOME HEIGHT NOTE ADDITIONAL 2 REQUIRED TO INSTALL OR REMOVE DOME DOME TOP OF ENCLOSURE HEADER 85 3 8 77 1 2 12 3 4 Y OF THRESHOLD 5 7 8 PE DEN UNIT WITH JACUZZI WHIRLPOOL BATH OPTIONAL STEAM ENCLOSURE Drain Down Locatio