1. 3 Press and hold SwitchLinc Set button until it double beeps Controller LED will stop blinking 4 Test by tapping controller button on and off If the responder is a multi scene device such as a KeypadLinc tap the scene button you wish to control until its LED is in the desired scene state on or off You can program any state not just on for the responder s link N S T E N f Page 7 of 15 Rev 1 21 2014 7 29 AM SwitchLinc will turn on at desired brightness and off Make SwitchLinc a Controller 1 Press and hold SwitchLinc Set button until it beeps LED will start blinking green 2 Adjust responder to desired brightness state 3 Press and hold responder Set button until it double beeps SwitchLinc will double beep and its LED will stop blinking 4 Test by tapping SwitchLinc paddle on and off Responder will turn on at desired brightness and off 5 To add more responders repeat steps 1 4 for each responder Groups Devices in a group remain synchronized Every device in a group is both a controller of and a responder to all the other devices The most common example of a group is a circuit with 2 switches referred to as a 3 way circuit Example group for a virtual 3 way circuit with SwitchLinc A and SwitchLinc B 1 Turn A and B on 2 Press and hold A Set button until it beeps A LED will start blinking green 3 Press and hold B Set button until it double beeps A will double beep and its LED will stop blinking A is
2. 5 Use a voltage meter to identify the line and load Load wires connected to the switch Red connected to light 6 Identify neutral and ground wires Line ___Black 120Vto Ground 1 f the wires cannot be detached by unscrewing them cut the wires where they enter the switch then strip 2 of insulation off the ends N S T E N Page 3 of 15 Rev 1 21 2014 7 29 AM 9 10 12 Turn off power Connect wires as per table diagram confirm firm attachments with no exposed wire If you are installing SwitchLinc in a multi gang box next to another switch you may need to remove one or both pairs of metal heatsink tabs on the back of SwitchLinc Note that removing a pair of tabs will derate SwitchLinc from 1000W to 800W one pair removed or 600W both pairs removed With LEDs on left gently place SwitchLinc into wall box and screw into place Turn on power some titi Diagram i SwitchLinc and its connected load will turn on a Verify SwitchLinc is working properly by tapping SwitchLinc on and off SwitchLinc and its connected load will turn on and off Reinstall the wallplate Installation Circuit with 2 Switches a k a 3 way circuit Circuits with 2 switches are called 3 way circuits Both switches in a 3 way circuit need to be replaced by SwitchLincs and or other INSTEON devices B Box 1 1 2 11 12 Turn off circuit breaker s and or remove fuse s feeding wall boxes verify that power is off P
3. gcc E adidas 9 Pape 10 Add palier m 10 Remove X TO Piteo cU 10 rige 10 Local Settings m 10 Local On Level e aiaa RE ced cake td Dope ed LER te aii fends 10 Local Ramp Rate EE 11 Change LED Brightness or turn it off enne en nennen nnne nnns 11 Beep on Button Press deett eder eg eed devine ERE Dna Ud e EXPL RE AU Eta ep cities dE EC adu 11 Error BINK qe 12 Elec e 12 Troubleshooling o odit eau enses rus ni T i dE 13 Certification and Warranty leeseeeeeeeeeeeeeses eese nennen nn nn annnm aant aaiae a assa sa sm Rusa sa ss saa sas naain 15 eT eio e EL 15 FCC and Industry Canada Compliance Statement sees 15 ETL UL Warning Safety Warning ener enne rnnt sn nennen nes 15 Lined i r p 15 lez 15 N S T E 5 N Page 2 of 15 Rev 1 21 2014 7 29 AM The Basics In the Box Tools Needed Optional Accessories SwitchLinc Dimmer High Wattage Flathead and Phillips screwdrivers INSTEON app Quick Start Guide Wire cutter stripper SmartLinc Hub 2 screws and 4 wire nuts Voltage meter Cautions and Warnings Read and understand t
4. Wires plus one traveler preferably black Not Used and note color of traveler you are using as this will carry line voltage to Box 2 11 Cap unused traveler wire N S T E b N a Page 5 of 15 Rev 1 21 2014 7 29 AM In Box 2 Traveler box 12 Connect SwitchLinc bare wire to ground Red Traveler Wires 13 Connect SwitchLinc white wire to neutral Not Used 14 Cap SwitchLinc red wire 15 Connect SwitchLinc black wire to same color traveler from Box 1 that you connected to line along with same color traveler wires leading to Box 3 16 Cap the last unused traveler wire s In Box 3 Load box 17 Connect SwitchLinc bare wire to ground 18 Connect SwitchLinc white wire to neutral 19 Connect SwitchLinc red wire to load 20 Connect SwitchLinc black wire to line traveler from Box 2 Line traveled from Box 1 through 2 into 3 usually black 21 Cap unused traveler wire 22 With LEDs on left gently place SwitchLincs into wall boxes and screw in place 23 Turn power back on SwitchLincs and connected load will turn on 24 Add all SwitchLincs to a group See Groups 22 Verify all SwitchLincs are working properly by tapping each on and off All SwitchLincs and the connected load will remain in synch 25 Reinstall wallplates j Ground Usually Copper or Green Local Control Follow these instructions to control the connected light load as well as any responders from the SwitchLinc paddle Connected Light an
5. Yes 915 MHz Wired in incandescent lighting fixtures 1000 watts uses 12 Amp triac dimmer No No Yes saved in non volatile EEPROM 0 59 watts FCC IC Canada ETL Intertek Testing Services to UL ANSI standard Troubleshooting Problem Possible Cause Solution will not turn on INSTEON SwitchLinc s LEDs and connected load SwitchLinc is not getting power Make sure the circuit breaker is turned on Check the light fixture to ensure all connections are tight and no bare wires are exposed Page 13 of 15 Rev 1 21 2014 7 29 AM The switch I m replacing only has two wires SwitchLinc needs a neutral wire in order to operate If there are white wires in wall box test them and if they are neutrals use them Pull a neutral wire to the wall box Purchase the 2 wire SwitchLinc 2474DWH in place of this SwitchLinc SwitchLinc is able to communicate with another INSTEON device The light turned on by itself SwitchLinc and the other device are out of range Install more INSTEON products including but not limited to Range Extenders Access Points The other device is near a localized powerline noise source or attenuator FilterLinc Another controller a timer or a stray X10 signal was received Isolate the noise attenuator using a Install a powerline signal blocker in your home to keep X10 signals from neighboring homes from interfering Consider not using SwitchLinc i
6. now a controller of B 4 Press and hold B Set button until it beeps B LED will start blinking green 5 Press and hold A Set button until it double beeps B will double beep and its LED will stop blinking B is now a controller of A A and B are now grouped 6 Test by turning load on and off from A and then B The load s and both A and B LEDs will remain in sync Scenes Scenes feature multiple responders each with its own unique individual settings activated from a single controller Responders in a scene can each have different settings This provides for advanced lighting audio etc in scene creation Home management software such as HouseLinc is recommended for scene management Example scene with one controller and SwitchLinc as a responder plus other responders 1 Press and hold controller button until it beeps Controller LED will start blinking 2 Tap controller Set button Controller LED will start double blinking 3 Adjust SwitchLinc to desired brightness for scene 4 Press and hold SwitchLinc Set button until it double beeps 5 For each additional scene member a Adjust member to desired scene brightness or state if not a lighting device b Press and hold member Set button until it double beeps 6 Press and hold controller Set button until it double beeps Controller LED will stop blinking 1 f the responder is a multi scene device such as a KeypadL inc tap the scene button you wish to control until its LED is in the desir
7. setting is adjustable via software or a central controller only N S T E N a Page 11 of 15 Rev 1 21 2014 7 29 AM Error Blink Default on This setting is adjustable via software or a central controller only SwitchLinc LED blinks for a few seconds if one or more responders do not acknowledge a message Specifications General Product name Brand Manufacturer product number UPC Warranty INSTEON INSTEON powerline mesh repeater INSTEON RF mesh repeater INSTEON controller INSTEON responder Maximum links scenes Load brightness levels Brightness of LEDs Local on level Local ramp rate Local control Commands supported as controller Commands supported as responder Software configurable RF range Phase bridge detect beacon INSTEON device category INSTEON device subcategory X10 X10 address X10 transmitter X10 receiver SwitchLinc Dimmer High Wattage INSTEON 2477DHxx White 2477DHWH 813922011005 Almond 2477DHAL Ivory 2477DHIV 2 years limited Yes Yes Yes Yes 400 32 256 when controlled by software Adjustable from off to 100 bright 4 locally increments of 1 with software 0 1 seconds to 2 seconds 0 125 seconds to 8 minutes via software O Off Fast on Fast off Brighten Dim O Off Fast on Fast off Brighten Dim 23 o Yes Up to 150 open air Yes 0x01 dimmable lighting control all frequencies 0x01 0x20 1 optional comes
8. CI might be too sensitive Relink SwitchLinc to your controller while its load is on Replace your AFCI with a less sensitive brand or model from a hardware store with a customer friendly return policy SwitchLinc modules do not trip when used with the vast majority of AFCI models and is known to not trip with the following models e GE 15 Amp Combination Arc Fault Breaker THQL1115AFP2 e Murray 2 Pole Combination Type Arc Fault Circuit Interrupter MP215AFCP There might be loose connections within your home s wiring Install a powerline noise filter such as a FilterLinc between the output and the lead The LEDS are too bright or too dim LED Brightness Adjust the LED brightness See Change If you have tried these solutions reviewed this Owner s Manual and still cannot resolve an issue you are having with SwitchLinc Dimmer High Wattage please call the INSTEON Support Line at 1 800 762 7845 INSTEON Page 14 of 15 Rev 1 21 2014 7 29 AM Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO a nationally recognized independent third party testing laboratory The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U S and Canadian device safety standards that the manufacturing site has been audited and that the manufacturer has agreed to a program of quar
9. SwitchLinc Dimmer High Wattage INSTEON Dual Band Remote Control Dimmer Owner s Manual rev 7 0 2477DHxxx i N S T m 5 N Page 1 of 15 Rev 1 21 2014 7 29 AM NOB 3 LSNI IIXILADLLT EI UT 3 CaUtlONS AMO REID aaia 3 Identifying the Electrical Wires in Your Home sssssseeeeeeeenenn een eee en errem nnne nns 3 Insta llaloniz s dnos cese I M A e MM Meli e oS SP ee EL 3 Installation Circuit with 1 Switch a k a 2 way circuit 3 Installation Circuit with 2 Switches a k a 3 way circuit 4 Installation Circuit with 3 or more Switches ssesssssssseseeerennennene nnne 5 Eie nimmer 6 hxpenE ld m 7 INSTEON Controllers Responders and Links esses enne nnne nnns 7 Make SwitchLinc a Responder ette rct eec ener rwn Tet ua ne Bs tu aaa aaeei iaaa 7 Make SwitchLbinc a Controllet ecce netu terr nee ener Foret aan br Us tua edo aea ia weed aye eda 8 GOUPS 20h C M ORR 8 Nl TE 8 Remove SwitchLinc as a Controller Unlink essssseeseseeeeeneeeenen nennen nnne 9 Remove SwitchLinc as a Responder Unlink ssessssseseeeen enne 9 Change Paddle or LED Colo aiite titre eec Get aree ta ee ctu erede Eae E ertet ea uen 9 Using Air Gap m O 9
10. Turn SwitchLinc off c Turn SwitchLinc back on Light will turn on at the defined brightness level Local Ramp Rate Default second The local ramp rate is the time it takes for SwitchLinc to reach 100 brightness from off when controlled at the paddle It is adjustable from instant to 8 minutes with software and instant to 5 seconds using Set button 1 Adjust SwitchLinc brightness corresponding to the desired local ramp rate in the table below Hint dim momentarily from 100 for 0 5 seconds or brighten momentarily from off for 2 0 seconds Brightness Ramp Rate 100 Instant 51 99 Ve second 01 50 2 seconds Off 5 seconds 2 Double tap Set button SwitchLinc will beep 3 Test by turning off and then back on via the local switch Light will ramp off and back on at the new local ramp rate Note if SwitchLinc recognized two single taps it will have adjusted the local on level instead of the local ramp rate Return to step 1 and try again Change LED Brightness or turn it off Default 50 bright Press and hold Set button until it beeps LED will start blinking green 2 Press and hold Set button until it beeps LED will start blinking red 3 Press and hold Set button until it beeps LED will stop blinking Use SwitchLinc on and or off buttons to brighten or dim LEDs to desired level 5 Tap Set button SwitchLinc will double beep and return to ready mode Beep on Button Press Default off This
11. d Responders Paddle Press and hold Double tap Top ramped until release instant On i Bottom ramped until release instant 1 If neutral is not available in this box use other unused traveler from Box 1 to carry neutral to Box 2 Label and mark any differently colored wire being connected to neutral with a piece of white tape to flag it as neutral N S T E N a Page 6 of 15 Rev 1 21 2014 7 29 AM INSTEON Setup Some products have subtle differences in their setup procedures Where necessary please refer to the other device s owner s manual for details INSTEON Controllers Responders and Links Let s define a few terms e Each INSTEON compatible product is called a device e The INSTEON transmitter is called a controller e The INSTEON receiver is called a responder e The association between the controller and responder is called a link e When a controller simultaneously controls multiple responders it is called a scene e When all members of a scene are synchronized always go on and off together it is called a group Basic INSTEON Link Link Controller Responder INSTEON Scene Controller Links Responders Note that a link is one way If you wish to have control the other way simply add a link the other way Make SwitchLinc a Responder 1 Press and hold controller button until it beeps Controller LED will start blinking Adjust SwitchLinc to desired brightness for link scene
12. dimming an inductive Load such as a fan or transformer could cause damage to the dimmer the load bearing device or both If the manufacturer of the load device does not recommend dimming use a non dimming INSTEON on off switch USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD Identifying the Electrical Wires in Your Home Line carries 120VAC electricity into the wall box may also be called hot live or power commonly black Neutral returns 120VAC to power company commonly white and in a multi wire bundle Load connects to light load device commonly black and in a separate cable jacket Ground connection to electrical ground commonly a bare wire a green wire or a screw on a metal box IMPORTANT If you have any difficulties or questions consult an electrician If you are not knowledgeable about and comfortable with electrical circuitry have a qualified electrician install the product for you Installation Installation Circuit with 1 Switch a k a 2 way circuit 1 At electrical panel turn off circuit breaker s and or SwitchLinc Wire Wall Box Wires remove fuse s feeding wall box Verify that the Ground power is off before continuing commonly bare 2 Remove wallplate from the switch Unscrew switch Bare copper copper green wire or and gently pull out o greenscrew 3 Disconnect wires from switch Neutral 4 Turn on power White commonly white
13. ed load will turn on only SwitchLinc in Box 2 will operate load Add both SwitchLincs to a group See Groups Verify both SwitchLincs are working properly by tapping on and off on each SwitchLinc Both SwitchLincs and the connected load will remain in synch Reinstall wallplates Installation Circuit with 3 or more Switches Circuits with 3 or more switches are called 4 way or 5 way etc All switches in 3 way 4 way circuits need to be replaced by INSTEON devices eo N 6 Turn off circuit breaker s and or remove fuse s feeding wall boxes verify that power is off Pull all three switches from their wall boxes 4 way and higher switches have 3 or 4 wires Remove wires from existing switches Make sure wires are safely separated from each other and turn power back on Using a voltage meter measure each wire to ground in all three boxes until you find the single wire supplying 120V line a We will now refer to that location as Box 1 b The location having 2 sets of matching pairs of wires will be Box 2 i e 2 reds and 2 blacks or other matching colors These are 2 travelers from Box 1 and 2 travelers leading to Box 3 c The last box will have the load wire That will be Box 3 Turn power back off In Box 1 Line box 7 Connect SwitchLinc bare wire to TRE erence Wiere Povar ground i 8 Connect SwitchLinc white wire to neutral 9 Cap SwitchLinc red wire 10 Connect SwitchLinc black wire to line Red Traveler
14. ed scene state on or off You can program any state not just on for the responder s link N S T E N a Page 8 of 15 Rev 1 21 2014 7 29 AM 7 Test by tapping controller button on and off SwitchLinc and all scene responders will turn on to desired brightness states and off Remove SwitchLinc as a Controller Unlink 1 Press and hold SwitchLinc Set button until it beeps LED will start blinking green 2 Press and hold SwitchLinc Set button until it beeps LED will start blinking red 3 Press and hold responder Set button until it double beeps SwitchLinc will double beep and its LED will stop blinking 4 Test by tapping SwitchLinc on and off Former responder will not respond Remove SwitchLinc as a Responder Unlink If you no longer want a controller button to control SwitchLinc follow these directions Important perform these steps for all controllers of SwitchLinc before removing SwitchLinc from use Otherwise controllers will retry commands repetitively creating network delays 1 Press and hold controller button until it beeps Controller LED will start blinking 2 Press and hold controller button until it beeps Controller LED will continue blinking 3 Press and hold SwitchLinc Set button until it double beeps Controller LED will stop blinking 4 Test by tapping controller button on and off SwitchLinc will no longer respond Change Paddle or LED Colors You can swap out the included white LEDs and or front paddle and trim f
15. f and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ETL UL Warning Safety Warning CAUTION To reduce the risk of overheating and possible damage to other equipment do not install this device to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance Gradateurs commandant une lampe a filament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente ou un appareil alimente par un transformateur Limited Warranty Seller warrants to the original consumer purchaser of this product that for a period of two years from the date of purchase this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner s Manual This warran
16. hese instructions before installing and retain them for future reference This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada Use indoors only This product is not designed or approved for use on power lines other than 120V 60Hz single phase Attempting to use this product on non approved power lines may have hazardous consequences Recommended installation practices Use only indoors or in an outdoor rated box Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into Installing this product with the power on will expose you to dangerous voltages Connect using only copper or copper clad wire This product may feel warm during operation The amount of heat generated is within approved limits and poses no hazards To minimize heat buildup ensure the area surrounding the rear of this product is as clear of clutter as possible Each INSTEON product is assigned a unique INSTEON I D which is printed on the product s label To reduce the risk of overheating and possible damage to other equipment do not use this product to control Loads in excess of the specified maximum s or install in locations with electricity specifications which are outside of the product s specifications If this device supports dimming please note that
17. n X10 mode If problem persists perform a factory reset See Factory Reset It takes a long time for one or more of SwitchLinc s responders to respond SwitchLinc is repeatedly retrying to control a missing responder If the responder is still available unlink it from SwitchLinc See Remove SwitchLinc as an INSTEON Responder Perform a factory reset See Factory Reset The load is buzzing when on or dim The dimming component inside SwitchLinc chops the powerline sine wave to reduce the power The bulb filaments are vibrating Use rough service 130V or appliance grade bulbs to reduce the noise Run SwitchLinc in full on mode or replace dimmer with and on off SwitchLinc SwitchLinc is locked up SwitchLinc is getting warm to the touch A surge or excessive noise on the powerline may have glitched it It is normal for wall dimmers to feel warm Pull the Set button on SwitchLinc all the way out to create an air gap wait 5 seconds then push it back in until it s flush with the trim frame don t push it all the way in If problem persists perform a factory reset See Factory Reset SwitchLinc can turn responder off but not on Your responder may be linked at off Relink your responder to SwitchLinc at desired on level My controller can turn SwitchLinc off but not on SwitchLinc trips the Arc Fault Circuit Interrupter AFCI SwitchLinc may be linked at its off The AF
18. ouble beep and LED will stop blinking 4 Test by sending X10 on and off commands SwitchLinc will turn on and off Remove X10 Address 1 Press and hold Set button until it beeps LED will start blinking green 2 Press and hold Set button until it beeps LED will start blinking red 3 Sendthe X10 address 3 times with or without commands SwitchLinc will double beep and LED will stop blinking 5 Test by sending X10 on and off commands SwitchLinc will no longer respond Other X10 Setup For other X10 setup instructions visit http www smarthome com insteon x10 programming html Local Settings Local On Level Default 100 fixed brightness The local on level is the brightness that SwitchLinc s connected load will come on when turned on at SwitchLinc paddle Local on level can be set to any one of 32 fixed brightness levels 3 to 100 or resume bright brightness prior to last being turned off To set local on level to a fixed brightness level 1 Adjust SwitchLinc to desired brightness when controlled locally 2 Tap Set button SwitchLinc will beep 3 Test by turning SwitchLinc off and then back on via the paddle SwitchLinc will turn on to new local on level To set local on level to the brightness level prior to being turned off 1 Turn SwitchLinc off N S T E N a Page 10 of 15 Rev 1 21 2014 7 29 AM 2 Tap Set button SwitchLinc will beep 3 Test a Brighten SwitchLinc to a random brightness level e g 7596 b
19. rame assembly with a color change kit before or after SwitchLinc is installed For more information see the Accessories page on INSTEON com Using Air Gap Anytime you want SwitchLinc s controlled load to be unpowered but don t want to turn off the circuit breaker such as when replacing light bulbs use the air gap to quickly and conveniently disable power to the connected load Using your fingernail or a small flathead screwdriver pull out SwitchLinc Set button as far as it will go about 1 8 This opens the mechanical contacts and removes all power from the SwitchLinc and its load Because SwitchLinc s settings are stored in its non volatile memory your setup information will not be lost To re enable power to SwitchLinc simply push in the Set button until it is flush with the trim frame Factory Reset All settings and scenes will be erased 1 Pull out SwitchLinc Set button to remove power 2 Wait 5 seconds 3 Push in Set button and hold it Do not let go SwitchLinc will emit a long beep N S T E 5 N a Page 9 of 15 Rev 1 21 2014 7 29 AM 4 When long beep stops release Set button A few seconds will pass SwitchLinc will double beep The connected load will turn on X10 Setup SwitchLinc ships with no X10 address assigned Add X10 Address 1 Turn SwitchLinc on 2 Press and hold Set button until it beeps LED will start blinking green 3 Sendthe X10 address 3 times with or without commands SwitchLinc will d
20. terly factory follow up inspections to verify continued conformance FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and Industry Canada RSS 210 Rev 7 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorise aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible d en compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no guarantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device of
21. ty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage prepaid with proof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call the INSTEON Support Line at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiving 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer Home a
22. ull both switches from their wall boxes each switch will have no less than 3 wires Remove wires from existing switches Make sure wires are safely separated from each other and turn power back on Using a voltage meter measure each wire to ground in both boxes until you find the single wire supplying 120V line a We will now refer to that location as Box 1 b The other box will have the load wire That will a be Box 2 Turn power back off In Box 1 Line box Connect bare SwitchLinc ground to bare ground wire or ground screw in wall box Connect SwitchLinc white wire to neutral wire s in wall box usually white Using a wire nut cap SwitchLinc red wire Connect SwitchLinc black wire to Line wire in wall box usually black along with one traveler wire e n H running between boxes preferably black Note he Cee on color of this traveler it will carry 120V line voltage to Box 2 Cap unused traveler In Box 2 Load box Connect SwitchLinc bare wire to bare ground wire or ground screw in wall box N S T E b N Page 4 of 15 Rev 1 21 2014 7 29 AM 21 Connect SwitchLinc white wire to neutral wire s in wall box usually white Connect SwitchLinc red wire to load wire Connect SwitchLinc black wire to same color traveler from Box 1 carrying Line usually black Cap unused traveler wire With LEDs on left gently place SwitchLincs into their wall boxes and screw in place Turn power back on SwitchLincs and connect
23. unassigned Yes Yes INSTEON Page 12 of 15 Rev 1 21 2014 7 29 AM X10 status response X10 resume dim X10 minimum transmit level X10 minimum receive level Mechanical Mounting Wires Case color Switch paddle and frame color Set button Plastic Beeper Beep on button press Status LEDs Dimensions Weight Operating environment Operating temperature range Operating humidity range Storage temperature range Electrical Voltage Neutral connection required Frequency Load type s Maximum load User replaceable fuse Hardwired remote control Retains all settings without power Standby power consumption Certifications Safety approval s Supported Supported by setting local on level to zero 3 2 Vpp into 5 Ohms 20mvV into 5 Ohms Mounts in single or multiple ganged junction box Control 200W less load for each immediately adjacent SwitchLinc Dimmer installed For example 600 W load control becomes 400 W with another dimmer to the immediate right or left Use a triple gang box with a mechanical switch in the center to avoid de rating Line black Load red Neutral white Ground bare copper White White Yes UV stabilized polycarbonate Yes Optional off by default 1 dual color red green and 9 white 4 1 Hx 1 8 W x 1 2 D 3 6 oz 102 grams Indoors 32 to 104 F 0 to 40 C 0 85 relative humidity 4 to 158 F 20 to 70 C 120VAC 10 60 Hz single phase
24. utomation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home In no event shall Seller be liable for special incidental consequential or other damages resulting from possession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to state Protected under U S and foreign patents see www insteon com Copyright 2012 INSTEON 16542 Millikan Ave Irvine CA 92606 800 762 7845 www insteon com N S T E b N a Page 15 of 15 Rev 1 21 2014 7 29 AM
Download Pdf Manuals
Related Search
Related Contents
Philips Forecast Passage User Manual and Instructions Model RRC²X - Rocket étude détaillée - Grand Livre d`Illustrator Equip 3m VGA M/F Heading 1 - Equinox Technologies UK Ltd. Kenwood eXcelon KDC-X579 CD Player - KDC 1-2. About the UFM-14DADA/18DADA - FOR OBJ_BUCH-2 609 932 356-001.book Copyright © All rights reserved.