Home
INSTEON 2475S2 Doll User Manual
Contents
1. an INSTEON Controller If you are no longer going to use an In LineLinc Relay that is controlling one or more INSTEON responders it is important that you unlink all of them from In LineLinc Otherwise the controller will retry commands and cause network delays Most responders use the unlinking procedure below 1 Press and hold In LineLinc s Set button until it beeps In LineLinc s status LED will start blinking 2 Press and hold In LineLinc s Set button until it beeps again Status LED will continue blinking You will have 4 minutes to complete the next step before unlinking mode times out 3 Press and hold responder s Set button about 3 seconds In LineLinc will double beep and its status LED will stop blinking 4 Confirm that unlinking was successful by tapping In LineLinc s On and Off buttons The load responder will not respond Advanced Features Creating INSTEON Scenes INSTEON scenes let you activate dramatic room ambiences with multiple lights and appliances For example you can set all the lights in a scene to dim to 50 or turn certain lights on while turning others off all with the tap of a button on a controller INSTEON scenes are very easy to set up just link more than one responder to the same On Off or scene button on a controller Then when you press any of the linked buttons on the controller all of the INSTEON devices linked in the scene will respond as a group To set up an INSTEON scene you can i
2. command three times For example to remove the address A1 send A1 ON A1 ON A1 ON 4 Once In LineLinc has received the preceding sequence it will double beep and automatically exit unlinking mode Additional Resources Find home automation solutions helpful tips interactive demos videos user forums and more at the INSTEON Learning Center www smarthome com learningcenter html Specifications General Product Name In LineLinc Relay Brand INSTEON Manutact rer Product Number SE INSTEON In LineLinc Relay Non Dimming with ense UPC 718122390618 Protected under U S and foreign patents see Paent Nameer www insteon com Page 10 of 14 Rev 1 21 2014 7 57 AM INSTEON Warranty Two years limited Operation Operation Modes INSTEON only X10 only INSTEON and X10 combo Combo Mode Message Order LED Indicator INSTEON INSTEON cleanup X10 Off when load is on and vice versa Multi Way Circuit Support As a receiver and a controller Setup Memory INSTEON Features Non volatile EEPROM INSTEON Address 1 hard coded out of 16 777 216 possible INSTEON Links 417 INSTEON Powerline Frequency 131 65 KHz INSTEON Minimum Transmit Level 3 2 Vpp into 5 Ohms INSTEON Minimum Receive Level 10 mV INSTEON Messages Repeated Yes Mechanical Mounting Mounts in single or multiple ganged junction box or fixture such as a
3. minutes to complete the next step before multi unlinking mode times out 4 One at atime press and hold each responder s Set button about 3 seconds If the responder is a multi scene device such as a KeypadLinc tap the scene button you want to unlink then press and hold the Set button When all the desired responders have been unlinked tap In LineLinc s Set button 6 Confirm that unlinking was successful by tapping In LineLinc s On and Off buttons None of the responders will respond Power Restore In LineLinc Relay stores all of its scenes properties etc in its internal non volatile memory so all settings are retained after a power outage Upon power being restored In LineLinc will return its connected load s and all LEDs to their states prior to power outage Factory Reset Factory Reset clears all user settings from In LineLinc Relay including INSTEON scenes on levels ramp rates X10 addresses etc 1 Make sure In LineLinc Relay is unlinked from all controllers 2 Turn off the breaker supplying power to In LineLinc Relay s fixture 3 Wait 10 seconds 4 Push in Set button and hold it While continuing to hold in the Set button have a partner turn on the circuit breaker 5 Release the Set button A few seconds will pass then In LineLinc will double beep The connected load will turn on Page 9 of 14 Rev 1 21 2014 7 57 AM INSTEON X10 Settings Setting the X10 Address Most INSTEON devices a
4. officially tested in a split single phase residential environment but has been known to work in many 3 phase systems with three dual band products installed one on each phase However due to the potential complexity of its troubleshooting the INSTEON Support Line is unable to support INSTEON in 3 phase environments Using In LineLinc Relay s Sense Wire Once connected In LineLinc s Sense wire will automatically turn on the load to which it is wired as well as any other devices linked to In LineLinc when it detects 120 Volts When In LineLinc no longer detects 120V it will turn the load and any linked devices off INSTEON commands will always override the Sense wire regardless of the Sense state So you can use a controller or In LineLinc itself to turn the load on and off at any time The Sense wire is enabled by default but it can easily be disabled and re enabled with In LineLinc s Set button or temporarily disabled with an INSTEON controller Disabling the Sense Wire 1 Press and hold In LineLinc s Set button until it beeps In LineLinc s status LED will start blinking 2 Double tap the Set button In LineLinc will beep and its status LED will stop blinking Status LED will turn on if load is off or off if load is on Re enabling the Sense Wire 1 Press and hold In LineLinc s Set button until it beeps In LineLinc s status LED will start blinking 2 Triple tap the Set button In LineLinc will beep an
5. In LineLinc Relay INSTEON Remote Control In Line On Off Switch with Sense Owner s Manual rev 5 1 2475S2 N Ma4dtLSN Page 1 of 14 247582 Rev 1 21 2014 7 57 AM In LineLinc Relay Features and Bene fits cccsecccceeeeeceeeeeeeeeeeseeeeeeeseeeseeeseeeeenseeeeeenseaeseenseeeeeenseeeeeenas 3 FEIEREN E dues deg ee dee Eege Sege EE Eege Seene E ege 3 Whar s1 the BOX ngre deiere enee dE Eegenen geed eE 4 Preparing to Install BUET BITTEN 4 Identifying the Electrical Wires in Your Home 4 MOOS Ee SO DEE 4 Mstalling MELINELING acoso ce a eat eect ewes eege 4 Using IneEineliine Relay crnina ee ecco EE Ee ee ee 6 Using the ON and OFF Buttons ee EENG nadie ddd eed ea eta elie 6 An Important Note About INSTEON Networks sccsseeeeseeeseeeeeseeeeneeeeeeeeeesaeseseeeenseeeseeeeeseaesaseenenseeeeeas 6 Split Single Phase vs 3 Phase Installaton nenn nenn 6 Using In LineLinc Relay s Sense Wir e cssccceseceseeeeesseeenseeeeeneeeseeeseseeeeeeneesaeseseeeenseeeseesesnaesnsneeeeeeeess 6 Disabling the TEE 6 Re enabling the Sense Wie 6 Temporarily Disabling the Sense Wie 7 Linking In LineLinc Relay as an INSTEON Responder ccesccceseeeeeeeeeeeeeeseaeseneeeeseeeseesesneesnseeeeneeaess 7 Unlinking In LineLinc Relay as an INSTEON Responder ssseesseesseesseesseessnessrnssrrssrnssnnsrnssrnssrnssrnssrnssrns 7 Linking In LineLinc Relay as an INSTEON Controller ccscccceseeesseeee
6. N devices in minutes INSTEON adapter for existing 120V sensors and in line module Independent Load wires control devices up to 120V Controls all incandescent lights and inductive loads up to 480 watts Status LED and beeper indicate setup activity Setup state stored in non volatile memory and preserved through power outages Wires in to standard junction boxes Neutral connection required Responds to X10 commands Two year warranty A i a On button ee l ERLE e j Status LED E o gt oo Off button Set button T PO wg a Page 3 of 14 247582 Rev 1 21 2014 7 57 AM What s in the Box In LineLinc Relay Quick Start Guide Six 6 wire nuts Preparing to Install In LineLinc CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada Use indoors only This product is not designed or approved for use on power lines other than 120V 60Hz single phase Attempting to use this product on non approved power lines may have hazardous consequences Recommended installation practices Use only indoors or in an outdoor rated box Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are ins
7. anty above No other representation or claim of any nature by any person shall be binding upon Seller or modify the terms of the above warranty and disclaimer Home automation devices have the risk of failure to operate incorrect operation or electrical or mechanical tampering For optimal use manually verify the device state Any home automation device should be viewed as a convenience but not as a sole method for controlling your home In no event shall Seller be liable for special incidental consequential or other damages resulting from possession or use of this device including without limitation damage to property and to the extent permitted by law personal injury even if Seller knew or should have known of the possibility of such damages Some states do not allow limitations on how long an implied warranty lasts and or the exclusion or limitation of damages in which case the above limitations and or exclusions may not apply to you You may also have other legal rights that may vary from state to state Protected under U S and foreign patents see www insteon com Copyright 2012 INSTEON 16542 Millikan Ave Irvine CA 92606 800 762 7845 www insteon com Page 14 of 14 Rev 1 21 2014 7 57 AM INSTEON
8. arantee that interference will not occur in a particular installation If this device does cause such interference which can be verified by turning the device off and on the user is encouraged to eliminate the interference by one or more of the following measures Re orient or relocate the receiving antenna of the device experiencing the interference Increase the distance between this device and the receiver Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ETL UL Warning Safety Warning CAUTION To reduce the risk of overheating and possible damage to other equipment do not install this device to control a receptacle a motor operated appliance a fluorescent lighting fixture or a transformer supplied appliance Gradateurs commandant une lampe a filament de tungstene afin de reduire le risqu de surchauffe et la possibilite d endommagement a d autres materiels ne pas installer pour commander une prise un appareil a moteur une lampe fluorescente ou un appareil alimente par un transformateur Limited Warranty Seller warrants to the original consumer purchaser of this product that for a period of two years from the date of purchase this product w
9. ble beeps In LineLinc s status LED will flash once then turn on if the load is off or off if the load is on 3 Confirm that unlinking was successful by tapping the controller button you just unlinked The load wired to In LineLinc will not respond Page 7 of 14 Rev 1 21 2014 7 57 AM INSTEON Linking In LineLinc Relay as an INSTEON Controller With the Sense wire connected you can control INSTEON responders based on the state of In LineLinc s load it will automatically activate the connected load and any other linked devices when it detects 120V such as when a motion detector is tripped then turn them off when it no longer senses 120V Be sure to link In LineLinc to responders before you finish installing it in its junction box To link multiple responders at once see Linking In LineLinc Relay to Multiple Responders Most responders use the procedure below 1 Press and hold In LineLinc s Set button until it beeps In LineLinc s status LED will start blinking You will have 4 minutes to complete the next step before linking mode times out 2 Set the responder to the state you want when activated from In LineLinc 3 Press and hold the responder s Set button for about 3 seconds In LineLinc will double beep and its status LED will stop blinking and turn on solid 4 Confirm that linking was successful by tapping the In LineLinc s On and Off buttons The responder will respond appropriately Unlinking In LineLinc Relay as
10. ceiling fan Wire Nuts 6 included Line black Load red Wires Neutral white Ground bare copper Sense yellow Dimensions 2 75 H x 1 75 W x 0 88 D Weight 2 9 OZ Operating Environment Indoors Operating Temperature Range 32 F to 104 F Operating Humidity Range Up to 85 relative humidity Electrical Supply Voltage 120V AC 10 60 Hz single phase Sense Voltage 120V AC Power Wire Leads 6 18 AWG stranded 600V 105 C insulation ends stripped and tinned Line black Load red Neutral white Sense yellow Load Wire Leads Ground Lead 6 14 AWG stranded 600V 105 C insulation ends stripped and tinned Line 1 red paired w Line Line 2 red 6 18 AWG stranded bare copper Compatible Load Types Wired in incandescent lighting and inductive loads Maximum Load 480 watts for incandescent loads INSTEON Page 11 of 14 Rev 1 21 2014 7 57 AM Maximum Amps 15 amps Standby power consumption 0 68 watts Certifications Safety tested for use in USA and Canada UL 507 CSA C22 22 14 05 X10 Features X10 Primary Addresses 1 X10 Scene Addresses 1 X10 Status Response Supported X10 Resume Dim Supported by setting local on level to zero X10 Powerline Frequency 120 KHz X10 Minimum Transmit Level 3 2 Vpp into 5 Ohms X10 Minimum Receive Level 20mV into 5 Ohms X10 Messages Repeated No Troubleshootin
11. d its status LED will stop blinking Status LED will turn on if load is off or off if load is on 3 Test the Sense wire by activating the load from the connected sensor such as turning it on from the local lamp switch walking by the motion detector and so on The load connected to In LineLinc will respond appropriately Page 6 of 14 Rev 1 21 2014 7 57 AM INSTEON Temporarily Disabling the Sense Wire The Sense wire may be temporarily disabled so that In LineLinc will not automatically send INSTEON commands or control its load regardless of change in sensor state For example if you are working or entertaining outside and you have motion sensors outside temporarily disable the Sense wire to keep the lights on even when no motion is detected NOTE The Sense wire can only be remotely disabled from an INSTEON controller You will not be able to temporarily disable the Sense wire by using the buttons on In LineLinc itself The following controllers are capable of disabling the In LineLinc Sense wire KeypadLinc RemoteLinc ToggleLinc SwitchLinc HouseLinc 2 Use Fast On or Fast Off under direct control To temporarily disable the Sense wire double tap any button controlling In LineLinc e Double tap ON to disable the Sense wire but keep the load on e Double tap OFF to disable the Sense wire but keep the load off To re enable the Sense wire simply activate from any controller or the buttons on In LineLinc itself Linki
12. eeeeeeeeeeseeeseseeeeeseeeseeesesneeenseeeeeenenss 8 Unlinking In LineLinc Relay as an INSTEON Controller A 8 Advanced Features eege Ee I Real a Read a Ar ian 8 Creating ER Gel Ee EE 8 Linking In LineLinc Relay to Multiple Responders AAA 8 Unlinking Multiple Responders from In LineLinc Heli 9 Ne Ve 9 Se 9 MT OSS le EE 10 Setting the X10 AGCreSS ee eeceetetivtedeetetyetdeletheavbarweteativhlevteleat ege Zeen genee e aa aaae aaa T eaat 10 Removma Rule ee 10 Additional e 10 Specifications siise espeare nre een rao ea deaa eEESE EES 10 TROUDIOSHOOUIN G WEE 12 Certification and Warranty EA EENS 14 Keren eeben tt te ten riede eege Segen eerst eegen stvaadebetwsservetsace Jee ees 14 FCC and Industry Canada Compliance Statement c cccccccceeeeeseeceeeeeceeeeeeaeeeeaeeseeeeeseaeeesaeeeeneessaees 14 ETL UL Warning Safety Wang 14 Bt WEE LI EE 14 Biel TEE TEE 14 Page 2 of 14 247582 Rev 1 21 2014 7 57 AM In LineLinc Relay Features and Benefits kl Congratulations on purchasing the high quality INSTEON In LineLinc Relay Switch with Sense With its easy install module you can not only add conveniently hidden remote control to the lights wired to In LineLinc but also automatic 120V sensing with the included optional Sense wire Along with controlling other devices In LineLinc itself can be remotely operated from other INSTEON controllers including other In LineLinc modules Features Quick setup links to other INSTEO
13. g Problem Possible Cause Solution Make sure the circuit breaker is turned on In LineLinc s status LED is not turning on and In In LineLinc is not getting LincLinc won t control the power load Check junction box wires to ensure all connections are tight and no bare wires are exposed Look in the rear of the junction box for a group of white wires all tied together with a wire nut Those are the Neutral wires Connect the Neutral In LineLinc wire there In LineLinc needs a Neutral wire in order to operate The switch l m replacing only has two wires In LineLinc and the controller Make sure two Access Points 2443 or other are on opposite powerline dual band INSTEON products are properly phases installed to detect the two powerline phases In LineLinc is not receiving signals from Powerline signals can t travel through power INSTEON or X10 Ges es is puggeainig filters Plugging the Controller directly into a controllers H p wall outlet works best Other modules are e Move the other modules or the controller to down the e another outlet Add new INSTEON devices or move around existing INSTEON devices All INSTEON In LineLinc is not linking devices act as INSTEON network repeaters to or working with an The INSTEON signal may be INSTEON controller or too weak device Make sure you are not experiencing interference with older X10 BoosterLinc technology Upgrade t
14. ill be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner s Manual This warranty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage prepaid with proof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the full extent of Seller s liability with respect to this product For repair or replacement during the warranty period call the INSTEON Support Line at 800 762 7845 with the Model and Revision of the device to receive an RMA and send the product along with all other required materials to INSTEON ATTN Receiving 16542 Millikan Ave Irvine CA 92606 5027 Limitations The above warranty is in lieu of and Seller disclaims all other warranties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warr
15. included wire nuts to connect the fixture s Line Load Neutral Ground and Sense wires if using to In LineLinc s corresponding wires 7 Enable power to the switch from the circuit breaker or fuse panel Use In LineLinc s On and Off buttons to test that In LineLinc is installed properly The load will turn on and off 9 Link In LineLinc to an INSTEON controller 10 Gently place In LineLinc into the junction box making sure nothing could accidentally press the buttons on its face 11 Reinstall the fixture Wiring Diagram Home s wire colors may vary Ceiling Electrical Box Groun Sense Switch Out Load fellow not used typically Red Usually Black Red or Blue Above wiring In LineLinc Relay without Sense below wiring In LineLinc with Sense Wiring Diagram Home s wire colors may vary In LineLine with Sense Ground Copper Floodlight Motion Sensor Page 5 of 14 Rev 1 21 2014 7 57 AM INSTEON Using In LineLinc Relay Using the ON and OFF Buttons The small button switches allows you to test the load and adjust its settings prior to final installation Tap ON button to turn load full on Tap OFF button to turn load full off An Important Note About INSTEON Networks Split Single Phase vs 3 Phase Installation For the best INSTEON network performance be sure you have properly installed at least two Access Points 2443 or other dual band INSTEON products INSTEON has only been
16. ndividually link each device to a controller Or save time and create multiple links at once by following the steps below Linking In LineLinc Relay to Multiple Responders 1 Adjust each responder you want In LineLinc Relay to control to the desired state 2 Press and hold In LineLinc s Set button until it beeps Page 8 of 14 Rev 1 21 2014 7 57 AM INSTEON In LineLinc s status LED will start blinking 3 Tap In LineLinc s Set button until it beeps again You will have 4 minutes to complete the next step before multi linking mode times out One at atime press and hold each responder s Set button about 3 seconds After you have linked all responders tap In LineLinc s Set button Confirm that linking was successful by tapping In LineLinc s On and Off buttons All the linked responders will respond appropriately oof rere Unlinking Multiple Responders from In LineLinc Relay If you are no longer going to use an In LineLinc Relay that is controlling one or more INSTEON responders or you are removing one or more of the responders it is important that you unlink all of them from In LineLinc This is an easy way to unlink multiple responders from In LineLinc at once 1 Press and hold In LineLinc s Set button until it beeps In LineLinc s status LED will start blinking 2 Press and hold In LineLinc s Set button until it beeps again Status LED will continue blinking 3 Tap In LineLinc s Set button You will have 4
17. ng In LineLinc Relay as an INSTEON Responder Be sure to link In LineLinc Relay to an INSTEON controller before you finish installing the fixture Refer to your controller device s Quick Start Guide or Owner s Manual to properly link it to In LineLinc Most controllers use the procedure below 1 Put your controller into linking mode For most INSTEON controllers press and hold the Set button for 3 seconds or the On scene button for 10 seconds You will have 4 minutes to complete the next step before linking mode times out 2 Press and hold In LineLinc s Set button until it double beeps In LineLinc s status LED will flash once then turn on if the load is off or off if the load is on 3 Confirm that linking was successful by tapping the controller button you just linked The load wired to In LineLinc will respond appropriately Unlinking In LineLinc Relay as an INSTEON Responder If you are no longer going to use an In LineLinc Relay that was linked to an INSTEON controller it is important that you unlink it Otherwise the controller will retry commands and cause network delays Most controllers use the unlinking procedure below 1 Put your controller into unlinking mode For most INSTEON controllers press and hold the Set button for 3 seconds twice or the On scene button for 10 seconds twice You will have 4 minutes to complete the next step before unlinking mode times out 2 Press and hold In LineLinc s Set button until it dou
18. o INSTEON compatible BoosterLinc modules 4827 In LineLinc doesn t The INSTEON controller may Relink In LineLinc to the INSTEON controller always respond to an have been reset without first See Adding In LineLinc Relay as an INSTEON Page 12 of 14 Rev 1 21 2014 7 57 AM INSTEON INSTEON controller unlinking In LineLinc from it Responder Install a powerline signal blocker in your home to keep X10 signals from neighboring homes from interfering Consider not using In LineLinc in X10 mode If the above doesn t work perform a factory reset See Factory Reset Install a powerline noise filter such as FilterLinc between the load and In LineLinc Install additional INSTEON devices to boost The load is producing the INSTEON signal Another controller a timer or Wi turned on by stray X10 signals triggered In i ees In LineLinc turns on but i electrical noise that is Increase the X10 signal strength with not off using another g gth with an controller 9 interfering with the reception INSTEON compatible X10 booster to of powerline signal overcome the power line noise Remove the X10 address from the button on your INSTEON controller so it doesn t send both INSTEON and X10 commands Unlike previous X10 only products In LineLinc does not Get up an X10 address See Adding an X10 have an X10 address set up at Address the factory In LineLinc doesn t resp
19. ond to X10 address A1 when first set it up Pull the Set button on In LineLinc all the way out to create an air gap wait 10 seconds then push it back in until it s flush with the trim frame don t push it all the way in If the above doesn t work perform a factory reset See Factory Reset A surge or excessive noise on the powerline may have glitched it In LineLinc is locked up In LineLinc can turn off my responder but nothing happens when send an ON command from In LineLinc Your responder may be linked Relink your responder to In LineLinc while the at its off state responding device is on My controller can turn off In LineLinc but In LineLinc does not turn on when send an ON command from my controller In LineLinc may be linked at its off state Relink In LineLinc to your controller while the load is on If you have tried these solutions reviewed this Owner s Manual and still cannot resolve an issue you are having with In LineLinc Relay please call the INSTEON Support Line at 1 800 762 7845 Page 13 of 14 Rev 1 21 2014 7 57 AM INSTEON Certification and Warranty Certification This product has been thoroughly tested by ITS ETL SEMKO a nationally recognized independent third party testing laboratory The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized c
20. onsensus of U S and Canadian device safety standards that the manufacturing site has been audited and that the manufacturer has agreed to a program of quarterly factory follow up inspections to verify continued conformance FCC and Industry Canada Compliance Statement This device complies with FCC Rules Part 15 and Industry Canada RSS 210 Rev 7 or 8 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le present appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorise aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible den compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installations This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio and television reception However there is no gu
21. re X10 ready meaning that they can respond to X10 commands from any X10 controller And it can send X10 commands to X10 devices However to operate an INSTEON device in X10 mode you must first set up an X10 address As it ships from the factory or after a factory reset procedure INSTEON devices will have no X10 address set up Follow these instructions to allow In LineLinc Relay to respond to X10 commands 1 Press and hold In LineLinc s Set button until it double beeps You will have 4 minutes to complete the next step before linking mode times out 2 From an X10 controller send the X10 address you want to assign followed by the ON command three times For example to use the address A1 send A1 ON A1 ON A1 ON 3 Once In LineLinc has received the preceding sequence it will double beep and automatically exit linking mode Removing the X10 Address If you are no longer going to control In LineLinc Relay with an X10 address it is very important that you unlink it Otherwise In LineLinc Relay will respond to the X10 command and may cause turn on by itself Follow these instructions to allow In LineLinc Relay to respond to X10 commands 1 Press and hold In LineLinc s Set button until it double beeps 2 Press and hold In LineLinc s Set button until it double beeps again You will have 4 minutes to complete the next step before unlinking mode times out 3 From an X10 controller send the X10 address you want to remove followed by the ON
22. rical ground commonly a bare wire a green wire or a screw on a metal box IMPORTANT If you have any difficulties or questions consult an electrician If you are not knowledgeable about and comfortable with electrical circuitry have a qualified electrician install the product for you Tools Needed Non conductive probe Phillips screwdriver Wire cutter stripper Voltage meter Installing In LineLinc _ _ _ _ _ gt L_ gt gt __S______ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _s 1 If you plan to configure In LineLinc using home management software such as HouseLinc or SmartLinc 2412N write down the INSTEON I D and the fixture in which it s being installed for future reference 2 Turn off the circuit breaker fuse panel supplying power to the fixture Check that the power is off by toggling the load on and off from its local switch 3 Remove wallpaper from the fixture unscrew it and remove from the junction box 4 Disconnect wires from fixture If the wires cannot be detached by unscrewing cut the wires where they enter the switch and strip 1 2 of insulation off the ends Make sure the wires are not touching anything 5 Turn on circuit breaker then use a voltage meter to identify the Line Load Neutral and Ground wires Once all wires are identified turn off circuit breaker again Page 4 of 14 Rev 1 21 2014 7 57 AM INSTEON 6 Referring to the diagrams below use the
23. talling this product into Installing this product with the power on will expose you to dangerous voltages Connect using only copper or copper clad wire This product may feel warm during operation The amount of heat generated is within approved limits and poses no hazards To minimize heat buildup ensure the area surrounding the rear of this product is as clear of clutter as possible Each INSTEON product is assigned a unique INSTEON I D which is printed on the product s label To reduce the risk of overheating and possible damage to other equipment do not use this product to control Loads in excess of the specified maximum s or install in locations with electricity specifications which are outside of the product s specifications If this device supports dimming please note that dimming an inductive Load such as a fan or transformer could cause damage to the dimmer the load bearing device or both If the manufacturer of the load device does not recommend dimming use a non dimming INSTEON on off switch USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD Identifying the Electrical Wires in Your Home Line carries 120VAC electricity into the wall box may also be called hot live or power commonly black Neutral returns 120VAC to power company commonly white and in a multi wire bundle Load connects to light load device commonly black and in a separate cable jacket Ground connection to elect
Download Pdf Manuals
Related Search
Related Contents
Elite-7 Combo Manuel d`utilisation Réf. 20811 Attitudes positives : AFFECTION, SANTÉ ET SÉCURITÉ [東レ]K-3ポイント添付文書 NT1 Type 400 Standalone - ADTRAN Support Community Samsung AS18A0RBD User Manual 給付金請求書 兼 医療照会同意書 Aurora H2O - GE Measurement & Control dmassist2 Bosch HWD5051UC Product Information Copyright © All rights reserved.
Failed to retrieve file