Home

Hunter Fan 45013-01 Fan User Manual

image

Contents

1. For Your Records and 7 Warranty Assistance 0 e VA z S For reference also attach your receipt or a copy J j AINA C F Ba NE AT of your receipt to the manual Owner s Guide and Installation Manual SINCE 1886 8 Form 45013 01 20100128 2010 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the 1 Getting Ready support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the 4 Wiring the Fan outlet box and associated wall switch location If you cannot lock 5 Installing the Canopy
2. from the ceiling plate and the green ground wire from the fan Connect the white wire ungrounded from the ceiling to the white wire ungrounded from the fan Connect the remaining wires as follows Dual Switch Wiring e The black wire ungrounded from the ceiling to the black wire ungrounded from the fan e The black white wire ungrounded from the fan to the wire ungrounded for the wall switch Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections Turn the wire connectors upward and push them carefully back through the ceiling plate into the outlet box Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 7 ala a Tix Wire Connector 45013 01 01 28 10 Hunter Fan Company 5 Installing the Canopy and Canopy Trim Ring 5 1 Partially install two canopy screws about 2 full turns in the Steps 5 1 5 2 Hanger Bracket hanger bracket j 5 2 Raise the canopy over the hanger bracket Align partially installed screws with key slots in canopy 5 3 Twist canopy clockwise to secure 5 4 Install third amp fourth canopy sc
3. into the sockets LJ 7 9 Ifthe fandangle is attached to the extra pull chain remove it now Attach the extra pull chain included to the fan pull chain using Breakaway the plastic breakaway connector You may find the plastic Connector breakaway connector on the end of the extra chain Thread the fan pull chain through the hole in the metal disc Then thread the fan pull chain through the hole in the center of the glass bowl Thread the light pull chain through the hole in the center of the glass bowl Then Thread the light pull chain through the hole in the center of the cover plate Thread the fan pull chain through the grommet hole in the side of Light Bulb the cover plate Sockets Place the cover plate up against the a daaa glass bowl Align the holes in the cover j Based 60 Watt plate and glass bowl l Maximum Thread the light pull chain through ia inal Metal Disc the finial and screw the finial onto the m threaded rod end until tight Metal Rod Reattach the fandangle to the extra pull chain a Glass Bowl q gt a Cover Plate a Finial 12 45013 01 01 28 10 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 7 17 7 18 7 19 7 20 Once you have uninstalled the light fixture continue To uninstall the light fixture first disconnect the plug connectors betwee
4. can overheat if serviced by untrained personnel If any servicing is required the product should be returned to an authorized service facility for examination or repair 7 6 To attach the lower switch housing connect the upper plug connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts the light kit to a maximum of 190 Watts Exceeding that limit or the marked limit on this product may result in fire hazard or improper operation lI lt _ ___ Plug Connector Steps 7 6 7 7 Lower Switch Housing Plug TT Connector Detail Housing O Assembly Screw 45013 01 01 28 10 Hunter Fan Company K2 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Installing the Glass Bowl 7 8 First install B10 candelabra bulbs 60 Watt Maximum
5. your preference Standard or Angled mounting The steps in this manual include instructions for both Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 3 45013 01 01 28 10 Hunter Fan Company l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e W
6. and Canopy the circuit breakers in the off position securely fasten a prominent Trim Ring warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade Fixture attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a Solid state speed control with this fan Use only Hunter speed controls Table Of Contents 2 Installing the Hanger Bracket 3 Assembling and Hanging the Fan 6 6 Assembling the Blades 7 Completing Your Installation With or Without a Bowl Light 2010 Hunter Fan Company 2 45013 01 01 28 10 Hunter Fan Company Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 2 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of two ways depending on ceiling height and
7. ed light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model 7 1 7 2 7 3 To attach the lower motor housing partially install two housing assembly screws into the switch housing mounting plate Feed the upper plug connector through the center opening of the housing Align the keyhole slots in the housing with the housing assembly screws 7 4 Turn the housing counterclockwise until the housing assembly 7 5 screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws firmly A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling If you want to install the light fixture proceed with step 7 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture in Step 7 17 Once you have uninstalled the light fixture continue with Step 7 6 10 45013 01 01 28 10 Hunter Fan Company K2 Lower Motor Housing 7 Completing Your Installation With or Without a Bowl Light Fixture Continued A CAUTION The light source is designed for this specific application and
8. et screw with a wrench or pliers A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod A WARNING Do not carry or lift fan by canopy Raise the fan and place the ball into the hanger bracket 3 5 Align the notch on the ball with the indent in the hanger bracket Rotate the fan until you hear the notch pop into place Go to 4 e Wiring the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 6 Steps 3 1 3 3 7 m Downrod lt Canopy a Canopy Trim Adapter Ring Steps 3 4 3 5 45013 01 01 28 10 Hunter Fan Company K2 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 4 2 4 5 4 7 Before attempting installation make sure the power is still off To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided Connect the bare or green ground wire grounded from the ceiling to the green ground wire grounded
9. fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Turn the fan off and let it come to a complete stop Slide the reversing switch on the fan to the opposite position Restart fan 45013 01 01 28 10 Hunter Fan Company 14 a J Reversing Switch In warm weather use downward air flow pattern In cold weather use upward air flow pattern 9 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug co
10. holes you drilled in the wood support structure For proper alignment a use slotted holes directly across from each other If you are Sei installing the fan on an ANGLED ceiling be sure to orient the hanger bracket as shown in Illustration 2 3 left or right view Note The isolators should be flush against the ceiling screws through the slotted holes in the hanger bracket into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten a Flat Washer Steps 2 2 2 4 Ceiling Peak Ceiling Peak Large Large n 3 Screw LEFT ALAALA a a Step 2 3 Angled Ceiling Only y 5 45013 01 01 28 10 Hunter Fan Company 3 Assembling and Hanging the Fan You can assemble your fan for standard or angled mounting as shown In steps 3 1 3 3 3 1 3 2 3 3 3 4 To assemble fan to hang down from a flat or angled ceiling place the canopy and canopy trim ring around the adapter so that they rest on the fan assembly Feed the wires from the fan through the downrod Note Make sure all the wires are on the same side of the metal dowel pin inside the dowrod Loosen the square head set screw on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the s
11. n the black wire and the black white wire Disconnect the plug connectors between the two white wires Remove the two screws attaching the light kit to the lower Lower Switch switch housing Housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the hole Install the dummy terminals included in the sack parts on the two disconnected wires in the lower switch housing Install the switch housing cap and plug button to the lower switch housing with step 7 6 OO0O0000000000 Male Dummy Terminal Cap Female Dummy gt gt Terminal Plug Button _ Step 7 22 13 45013 01 01 28 10 Hunter Fan Company 8 1 8 Operating and Cleaning Your Ceiling Fan Turn on electrical power to the fan 8 2 The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off 8 3 8 4 8 5 e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector Ceiling
12. nnection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights turn off when installed or dim when turned on 1 Check to make sure the wattage and type of light bulbs installed match the specifications on the light socket Problem Lights shut off suddenly 1 Turn the power to the fan off at the wall switch Wait 30 seconds then resume power to the fan If you need parts or service assistance please call 888 830 1326 In Canada call 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Parkway 400 Memphis Tennessee 38016 45013 01 01 28 10 Hunter Fan Company
13. rench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 Preparing the Fan Site Before you begin installing the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 45013 01 01 28 10 Hunter Fan Company K2 2 1 2 2 2 3 Place a flat washer on each of the two 3 screws and pass the 2 Installing the Hanger Bracket Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 ea in diameter D Note Your fan comes with four pre installed mounting isolators Neg racke Thread the lead wires from the outlet box down through the hole Z in the middle of the hanger bracket aa e e e e Align the slotted holes in the hanger bracket with the pilot
14. rew in round hole on canopy Securely tighten all four screws Canopy Trim Ri 5 5 Using both hands push the canopy trim ring up to the top of the Canopy y a canopy 5 6 Twist canopy trim ring clockwise to secure the canopy Should you need to remove the canopy trim ring follow these steps 1 Twist canopy trim ring counter clockwise until it releases from canopy Step 5 5 8 45013 01 01 28 10 Hunter Fan Company 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Install the grommets into the blades by hand Step 6 1 Detail 6 2 Place each blade between a blade iron and medallion Install three blade screws to attach the medallion to the blade iron Repeat for all blades 6 3 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet screws Use without grommet Blade Mounting Screw 45013 01 01 28 10 Hunter Fan Company Steps 6 2 6 4 7 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the includ