Hunter Fan 30785 Air Cleaner User Manual
Contents
1. SINCE 1886 ed asas NINE N i mm 1 mm Ter a 1 E as El a e 2 SD NOM Models 30785 amp 37785 Replacement Filter Information Model Carbon Odor Filter QuietFlo Filter 37785 30901 30943 www hunterfan com 42937 01 07 27 2007 2007 Hunter Fan Company Table of Contents Safety Instructions a rsssssssssssssssssssssssssss 3 IMTTOUCTION u uu anasinin aaa aaa aaa aaa aaa aaa ai 3 Bm Description of Air Filtration System How the Air Purifier Works uu u au eeen 4 Air Purifier Components sesira ennaa aE E 4 Display and Control Keys ay u i Renee eee ie eee 5 z y Operation V C Ni NSF AA 6 Locking Unlocking the Keypad 8 Filter Life Counters 9 Resetting the Air Purifier cccc ccccecseeeeeeeeeeeeeeeeeeeeeseeeeeeeeneeeeetees 9 Fi Air Purifier Maintenance Cleaning Your Air Purifier cccccccceeceeceeeeeeeeeeeeeeneeeeeesneeeseneaees 10 Cleaning the Pre Filters 8 Changing the Carbon Odor Filter 10 Changing the QuietFlo Main Filter ccccccccccscsesssseseseseteeeseceees 11 Obtaining Replacement Filters u u u u 12 Troubleshooting Problem and Solutions cccccccecee
2. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DU RATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORA PARTICULAR PURPOSE IN RESPECT TO THE MOTOR IS EXPRESSLY LIMITED TO THE PE RIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE This warranty is voided if the Air Purifier is not purchased and used in the USA or Canada This warranty excludes and does not cover defects malfunctions or failures of the Air Purifier which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling modifications or damage to the Air Purifier while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance This warranty does not cover Air Purifiers used in commercial applications There are no express or implied warranties as to commercial purchasers or users To obtain service contact the Hunter Fan Company Service Department 2500 Frisco 42937 01 14 Warranty J Avenue Memphis Tennessee 38114 1 888 830 1326 You will be responsible for insurance and freight or other transportation to our factory service center We will return the Air Purifier freight prepaid The Air Purifier should be properly packaged to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present
3. Internet at www hunterfan com 13 42937 01 9 Warranty Hunter Fan Company QuietFlo Plus Air Purifier 5 YEAR LIMITED WARRANTY The Hunter Fan Company makes the following limited warranty to the original resi dential user or consumer purchaser of the QuietFlo Plus Air Purifier If any part of your QuietFlo Plus Air Purifier motor or control panel fails during the first five 5 years from the date of installation due to a defect in material or workman ship we will provide a replacement Air Purifier free of charge Installation is deemed to occur at the date of purchase If the Air Purifier cord or front grill fails any time within one 1 year after installation due to a defect in material or workmanship we will replace or at our option repair the unit free of charge at our nearest service center or at our Service Department in Memphis Tennessee You will be responsible for all parts and labor costs after this one year period USE OF A NON HUNTER FILTER WILL INVALIDATE THIS WARRANTY IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER PURCHASER CEASES TO OWN THE Air Purifier THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WAR RANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT TO THE FILTER MATERIAL OR CARBON FILTER
4. room O Dust amp Irritants m Pollen amp Allergens ei Odors Bacteria gt lt Pet Hair amp Dander NAS ny Pre Filter QuietFloQ Carbon Filter Odor Filter 99 97 1 Microns Fig 1 Illustration of the Air Filtration System Air Purifier Components QuietFlo MAIN CARBON oDOR FILTER FILTER FRONT GRILL PRE FILTER ONE ON EACH SIDE 3 5 3 Fig 2 Air Purifier Components 42937 01 4 Description of Air Filtration System w Display and Control Keys The display and control keys allow for easy operation of the Air Purifier FAN SPEED CONTROL Sets the fan speed PRE FILTERS amp CARBON ODOR FILTER RESET Resets the Pre Filter and Carbon Filter Life Counter QuietFlo MAIN FILTER RESET Resets the QuietFlo Main Filter Life Counter ON OFF KEY Turns the fan on and off NOTE The ON OFF key oper ates the fan ONLY The LCD Display will remain on even when the fan is off PRE FILTERS amp CAR PRE FILTERS amp CARBON KEYPAD QuietFlo MAIN FILTER QuietFlo MAIN BON ODOR FILTER ODOR FILTER LIFE COUNTER LOCKICON LIFE COUNTER FILTER RESET gt s mint o V0 ON OFF KEY FAN SPEED FAN OPERATION FAN SPEED ICONS ANIMATED CONTROL Fig 3 Air Purifier Control Panel 5 42937 01 Ne Operation Initial Operation This section provides basic instructions on the use of your Air Purifier After following these
5. the exact life of the filters depends on the environment the table below gives typical usage times of the filters Table 1 Typical Usage Times of the Filters Filter Type Typical Usage QuietFlo Main Filter 8000 hours Pre Filter Carbon Odor Filter 2000 Hours When the Pre Filters amp Carbon Odor Filter Life Counter reaches 0 clean the Pre Filters and change the Carbon Odor Filter Replace the QuietFlo Main Filter when the QuietFlo Main Filter Life Counter reaches 0 The values of the Filter Life Counters are stored in the Air Purifiers memory The unit may be unplugged and moved or stored without losing the Pre Filter and Filter Counter values To properly track filter life reset the Filter Life Counters each time the filters are changed or cleaned Refer to Pre Filters amp Carbon Odor Filter pg 10 or Chang ing the QuietFlo Main Filter pg 11 sections for instructions on how to reset the counters Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the Air Purifier If you still have problems after resetting the Air Purifier please contact Hunter for additional assistance refer to Technical Support pg 14 To Reset the Air Purifier 1 Unplug the unit for at least 30 seconds 2 Plug the unit back in 9 42937 01 3 o Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure yea
6. to set the fan speed Refer to Fig 8 ACTIVE MEDIUM TURBO CLEAN FAST SLEEP SLOW Fig 8 42937 01 Ne Operation Locking Unlocking the Keypad Once you enter the desired speed you may want to lock the keypad to prevent ac cidental changing of the speed When the keypad is locked all keys will be disabled If you press a key the Keypad Locked Indicator will be displayed on the screen for 1 2 seconds 1 To lock the keypad press and hold the QuietFlo Main Filter Reset key and the Fan Speed Control key simultaneously for 2 3 seconds The Keypad Locked Icon will appear on the display Refer to Fig 9 After releasing the keys the Keypad Locked Icon will disappear KEYPAD LOCK ICON 2 To unlock the key pad press and hold the QuietFlo Main Filter Reset key and the Fan Speed Control key simultaneously for 2 3 seconds The Keypad Locked Icon will disappear and the keypad will be functional Using the LCD Backlight 1 To turn on the LCD Backlight press and hold the Pre Filter and the Main Filter keys for 3 seconds To turn the LCD Backlight off repeat the process 42937 01 8 Operation WA Filter Life Counters The Pre Filters Carbon Odor Filter and QuietFlo Main Filter are critical to the proper operation of the Air Purifier To help you know when to clean and change the filters your Hunter Air Purifier has Filter Life Counters that will monitor the life of your filter Although
7. READ AND SAVE THESE INSTRUCTIONS Introduction Thank you for purchasing the QuietFlo Plus Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed to improve the quality of the air that you breathe The following innovative features are included in your Hunter Air Purifier e High Particulate Efficiency The QuietFlo filter will remove 99 97 of 0 3 micron particles from the air that passes through the filter e Odor Removal The activated carbon filter helps remove odors such as cooking smoke and pet smells from the air e Quiet The Air Purifier has been designed to operate quietly and efficiently You can choose among three speeds to best meet your needs at different times Filter Counters Filter maintenance is critical to the performance of the Air Purifier To help you determine when to change the carbon filter the pre filters and QuietFlo filter the unit has built in life counters that keep track of the life remaining of each filter 3 42937 01 03 Description of Air Filtration System How the QuietFlo Plus Air Purifier System Works As the air is pulled into the Air Purifier the Pre Filters capture large particles Then the air travels through the QuietFlo Main Filter where the smaller particles are col lected Odors are removed as the air passes through the Carbon Odor Filter Finally the clean purified air is released back into the
8. eeceeceeeeeeeeeeseeeeeeeeeeeeeeeneeeesees 13 Technical SUpport oisi u Genie ee ee eee ee ee eee 13 H Warranty Information ei u ir e a a 14 Yeats 42937 01 2 SAFETY INSTRUCTIONS IMPORTANT READ ALL INSTRUCTIONS BEFORE USING THIS Air Purifier 1 This Air Purifier is designed for use on a flat level floor and may not work properly on an uneven floor ALWAYS place the Air Purifier on a firm level floor ALWAYS place the Air Purifier at least six 6 inches away from walls and heat sources such as stoves radiators or heaters 2 Place the Air Purifier in an area that is out of the reach of children 3 Before using the Air Purifier extend the cord and inspect for any signs of damage DO NOT use the product if the cord has been damaged 4 This product has a polarized plug one blade is wider than the other as a safety feature This plug will fit into a polarized outlet only one way If the plug does not fit fully into the outlet reverse the plug If the plug still does not fit contact a qualified electrician DO NOT attempt to defeat or override this safety feature 5 ALWAYS UNPLUG the Air Purifier while it is being cleaned 6 DO NOT move or tilt the Air Purifier while it is in operation Turn off and unplug before moving 7 DO NOT immerse the Air Purifier in water at any time because permanent damage will occur To properly clean your Air Purifier follow the instructions in the Maintenance section of this manual pg 10
9. er to return to normal operation To change the filter and reset the Filter Life Counter FILTER RIM First turn off and unplug the Air Purifier Next remove the Front Grill Place your fingers under the Grill Release Handle and pull up Refer to Figs 4 and 5 pg 6 Lift the Filter Tab and gently pull the filter out of the unit Refer to Fig 6 While removing the filter note the filter s orientation the new filter will be installed with the same orientation Refer to Fig 10 Once removed the used filter can be discarded To install a new filter position the filter with its rim facing the unit Refer to Fig 10 FILTER FRAME I Fig 10 11 42937 01 5 Place the bottom of the filter rim behind the ridges on each side of the bottom of the unit Refer to Fig 11 Fig 11 6 Lift the Filter Tab and press the top of the filter into the Air Purifier To avoid damaging the filter you should press only on the filter s frame When the new filter is in place release the Filter Tab 7 Place the front grill back onto the unit Refer to Figs 7 pg 7 NOTE This unit will not operate unless the grill is in the correct position 8 Plug the unit in and continue operating it normally 9 To reset the QuietFlo Main Filter Life Counter to zero press and hold the QuietFlo Main Filter Life Counter Reset Key for three seconds When the display shows 100 release the Key The Counte
10. filters To clean the Pre Filters Change the Carbon Odor Filter and reset the Pre Filters amp Carbon Odor Filter Life Counter 1 First turn off and unplug the Air Purifier 2 Next remove the front grill Refer to Figs 4 and 5 pg 6 3 Remove the Pre Filters Refer to Fig 2 pg 4 Use a vacuum cleaner to remove dust from them Then reinsert the Pre Filters into the Air Puri fier 4 The Carbon Odor Filter is held to the back of the Front Grill with four hook and pile fasteners Peel off the old Carbon Odor Filter 5 If needed use a soft damp cloth to wipe off the Front Grill Gently press a new filter into place 42937 01 10 Air Purifier Maintenance B NS 6 Place the Front Grill back onto the unit 7 Plug in the Air Purifier 8 To reset the Pre Filters 8 Carbon Odor Filter Life Counter to zero press and hold the Pre Filters amp Carbon Odor Filter Reset Key for three sec onds When the display shows 100 release the Key The Counter is now reset Changing the QuietFlo Main Filter When the QuietFlo Main Filter Life Counter reaches 0 approximately 10 to 12 months of use you should replace the filter Refer to Filter Life Counters for ad ditional information pg 9 The proper time to change the filter depends on usage and the environment Generally if you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Replace the filt
11. initial directions please continue reading this booklet to learn how to operate the more advanced features of your Air Purifier Basic Operation of the Air Purifier 1 Take the Air Purifier out of the box and remove the clear plastic protec tive bag Place the unit on a firm level floor 2 Before turning on the Air Purifier you need to confirm that the QuietFlo Main Filter is firmly in place and has not become loose during shipping To check the filter remove the front grill by placing your fingers under the grill release handle and pulling the handle up Refer to Figs 4 and y 15 1 III GRILL RELEASE HANDLE Fig 4 Fig 5 3 Inspect the filter to ensure the bottom of the filter is secure and the top of the filter is behind the filter tab Refer to Fig 6 FILTER TAB FILTER Fig 6 42937 01 Operation Y 4 Ifthe filter is secure place the front grill back onto the unit Place the grill over the front of the Air Purifier and lower it into position Refer to Fig 7 NOTE This unit will not operate unless the grill is in the correct position If the filter is not secure refer to the section Changing the QuietFlo Main Filter pg 14 WYA l IIL m s m sss ss ss _ 30100 Fig 7 5 Plug the unit into a 120V electrical outlet and press the ON OFF Key The fan will begin to blow air from the front of the unit 6 Use the FAN SPEED CONTROL Key
12. r is now reset Obtaining Replacement Filters To obtain replacement filters for your Air Purifier first determine your model number by looking at the information label on the bottom of the Air Purifier The model num ber will be listed on the label Then call 1 800 4HUNTER for your nearest retailer or Hunter Customer Service at 1 800 313 3326 CAN 1 888 855 8300 to order directly To order online visit our Website at www hunterfan com To ensure that you obtain the correct filters please find your model number below that specifies the correct replacement filters Hunter Air Purifier Model No 37785 Carbon Odor Filter Replacement Model No 30901 HEPAtech Filter Replacement Model No 30943 42937 01 12 Troubleshooting K Problem Solutions 1 No display or operation e Confirm that the unit is plugged in e Check the installation of the front grill e Reset the Air Purifier See Resetting the Air Purifier on pg 9 2 Erratic Operation e Reset the Air Purifier See Resetting the Air Purifier on pg 9 4 Unit has reduced air The filters are clogged and should be cleaned flow or increased noise changed Refer to Cleaning the Pre filters and Changing the Carbon Odor Filter on pg 10 and QuietFlo Main Filter on pg 11 Technical Support If you have any additional questions or problems with your Hunter Air Purifier please call 1 888 830 1326 from 8 00 am to 5 00 pm Central Time or contact us over the
13. rs of trouble free service Follow these steps to properly maintain your Air Purifier 1 Approximately every 90 days the outside of the unit should be cleaned with a soft damp cloth 2 If needed the Front Grill can be removed from the unit and cleaned with soapy water NOTE Remove the Carbon Odor Filter before exposing the Front Grill to water 3 Follow the instructions in Cleaning the Pre Filters and Changing the Carbon Odor Filter pg 10 and Changing the QuietFlo Main Filter pg 11 to determine when and how to replace the filters NOTES e The Air Purifier must be unplugged during the cleaning process e Be sure the unit is completely dry before plugging in and using e Never immerse unit in water Cleaning the Pre Filters and Changing the Carbon Odor Filter When the Pre Filter exceeds 2000 hours refer to Filter Life Counters for additional information pg 9 the Pre Filter indicator will turn on as a reminder that you should clean the Pre Filter and change the Carbon Odor Filter To maintain proper odor removing capability and overall filtration performance the Pre filters should be cleaned and the Carbon Odor filters replaced every 2000 hours approximately 3 months of use If necessary clean the pre filter and change the odor filter more often Proper maintenance of the pre filter will help extend the life of the QuietFlo filter Refer to Obtaining Replacement Filters pg 13 if you need help finding replacement
14. sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT IN DIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE Air Purifier YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW e LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS e THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCI DENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE 15 42937 01 T Other Home Comfort Products from Hunter Hunter Originale The Care Free Programmable Fans Humidifier Thermostat To learn more about Hunter Fan Company products please see our Web page at www hunterfan com T HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS TN 38114 USA 42937 01 Printed in China and Taiwan
Download Pdf Manuals
Related Search
Related Contents
第150回定時株主総会 招集ご通知(修正版) LA LETTRE DE KITRI - Communauté de Communes des Pays du SD-SG11 Configuración del RAID de hardware en SIMATIC 951-130-441 EN アイロン掛けをしよう Sistema modular de policarbonato celular bi-protegido U.V. Compact NSX 100/630A Sistema ULP Stairmate STANDARD manuel d`utilisation FR ed 2006 LG LDS5540BB Energy Guide Copyright © All rights reserved.