Home
Hunter Fan 30715 Air Cleaner User Manual
Contents
1. Filtration System To ensure the best air circulation in the room we recom mend that you place your air purifier six 6 inches away from any walls To turn the ionizer on or off 8 1 To turn the ionizer on press the IONIZER key The lonizer N J Indicator will appear on the display Refer to Fig 10 Va 2 To turn the ionizer off press the IONIZER key The lonizer lt Indicator will disappear Controlling the Backlight Your air purifier display has a backlight that is continuously lit as long as there is power to the unit The backlight may be turned off To turn the backlight off or on Press the PRE FILTER RESET and FILTER RESET keys at the same time NOTE Do not hold down the keys for longer than 2 seconds This may reset a and filter counter NANNA Y 43010 01 10 Air Purifier Maintenance 3 Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service Follow these steps to properly maintain your air purifier 1 Approximately every 90 days the outside of the unit should be cleaned with a soft damp cloth 2 If needed the front grill can be removed from the unit and cleaned with soapy water Simply remove the pre filter before exposing the grill to water 3 Follow the instructions in Changing the Pre Filter and Cleaning the Filter pgs 11 and 12 to determine when and how to replace or clean the filters NOTES e The air pu
2. Then the air travels through the HEPAtech Filtration System where the smaller particles are collected Then the ionizer releases negative ions into the air that attract positively charged dust smoke and pollen particles Finally the clean purified air is released back into the room dustairitants IMI pollen amp allergens Odors Bacteria pet Hair amp Dander Carbon Carbon HEPAtech lonizer Pre filte Pre filter Filtration System 99 97 0 1 Microns Fig 1 Illustration of the Air Filtration System Air Purifier Components HEPATECH FILTER BASE PRE FILTER Fig 2 Air Purifier Components 43010 01 4 Description of Air Filtration System w Display and Control Keys The display and control keys allow for easy operation of the air purifier UP DOWN KEYS Adjusts the blower speed and turns the unit on and off PRE FILTER RESET Resets the Carbon Pre Filter Life Counter FILTER RESET Resets the HEPAtech Filter Life Counter IONIZER KEY Turns the ionizer on and off PRE FILTER RESET PRE FILTER KEYPAD IONIZER CLEANABLE KEY LIFECOUNTER LOCKED INDICATOR FILTER LIFE FILTER RESET INDICATOR COUNTER OFF SPEED KEY KEY IONIZER KEY TURBO KEY CARBON PRE FILTER BLOWER INFRARED ANIMATED CLEANABLE INDICATOR SPEED RECEIVER BLOWER FILTER INDICA TOR Fig 3 Air Purifier Control Area and Alpha numeric Display 5 43010 01 Operation Initial Operation This section
3. Counter 1 First turn off and unplug the Air Purifier 2 Next remove the Front Grill Place your fingers under the Grill Release Handle and pull up Refer to Figs 4 and 5 pg 6 3 Lift the Filter Tab and gently pull the filter out of the unit Refer to Fig 6 While removing the filter note the filter s orientation the new filter will be installed with the same orientation Refer to Fig 10 Once removed the used filter can be discarded While removing the filter note the directional arrows printed on Continued 43010 01 12 Air Purifier Maintenance f the top of the filter The filter will be reinstalled with the same orientation Refer to Fig 12 4 To install a new filter position the filter with its rim facing the unit Refer to Fig 12 5 Place the bottom of the filter rim behind the ridges on each side of the bottom of the unit Refer to Fig 11 6 Lift the Filter Tab and press the top of the filter into the Air Purifier To avoid damaging the filter you should press only on the filter s frame When the new filter is in place release the Filter Tab 7 Place the front grill back onto the unit Refer to Figs 6 and 7 pg 7 NOTE This unit will not operate unless the grill is in the correct position 8 Plug in the unit 9 To reset the Filter Life Counter to zero hours and turn off the indicator press and hold the HEPAtech Filter Reset Key for three seconds then release it 10 To rest the counte
4. first be sure that the remote is facing the air purifier when pressing the key If it still does not work check the batteries 43010 01 8 Operation WA Filter Life Counters The pre filter and filter are critical to the proper operation of the air purifier To help you know when to clean or change the filters your Hunter Air Purifier has Filter Life Counters that will monitor the percentage of life your filter has left Although the exact life of the filters depends on the environment the table below gives typical usage times of the filters Table 2 Typical Usage Times of the Filters Filter Type Typical Usage Activated Carbon Pre Filter 1400 hours HEPAtech Filter 2800 hours The display shows the percentage of life left since the counter was reset NOTE The per centage level drops in 5 increments The values of the Pre Filter and Filter Life Counters are stored in the air purifier s memory The unit may be unplugged and moved or stored without losing the Pre Filter and Filter Counter values To properly track filter usage the Pre Filter and Filter Life Counters should be reset each time the filters are changed or cleaned Refer to Changing the Pre Filter pg 11 orChang ing the HEPAtech pg 12 for instructions on how to reset the counters Locking Unlocking the Keypad Once you enter the desired speed you may want to lock the keypad to prevent accidental changing of the speed When the keypad is lo
5. provides basic instructions on the use of your air purifier After following these initial directions please continue reading this booklet to learn how to operate the more advanced features of your air purifier Basic Operation of the Air Purifier 1 Take the air purifier out of the box and remove the clear plastic protective bag Place the unit on a firm level floor 2 Before turning on the air purifier you need to confirm that the filters are firmly in place and have not become loose during shipping To check the filters first open the front grill Release the front grill by placing your fingers under the handle on the grill and pull forward then up Refer to Figs 4 and 5 HANDLE PULL FORWARD THEN UP Fig 4 Fig 5 3 Next check the HEPAtech filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening 4 The carbon pre filter is mounted inside the front grill with hook tape Confirm that it properly covers the grill vents You may notice a few black particles coming off the pre filter Those particles are part of the odor removing activated carbon and will be collected on the filter during use 43010 01 6 Operation W 5 Place the front grill back onto the unit First line up the tab on the bottom of the grill with the recess on the purifier base and then push the top of the grill forward until it is closed Refer to Figs 6 and 7 NOTE This uni
6. to improve the quality of the air that you breathe The following innovative features are included in your Hunter Air Purifier High Particulate Efficiency The HEPAtech filter will remove 99 97 of 0 1 micron particles from the air that passes through the filter Odor Removal The activated carbon pre filter helps remove odors such as cooking smoke and pet smells from the air It also traps lint hair and other large particles to help extend the life and performance of the HEPAtech filter lonizer The ionizer improves the quality of air in the room by releasing negative ions into the air that attract positively charged dust smoke and pollen particles Quiet The air purifier has been designed to operate quietly and efficiently You can choose among three speeds to best meet your needs at different times Filter Counters Filter maintenance is critical to the performance of the air purifier To help you determine when to change the pre filter and HEPAtech filter the unit has built in life counters that keep track of the life remaining of each filter NiteGlo Light Your air purifier display has a backlight that is continuously lit as long as there is power to the unit You can choose to turn the backlight off or on 3 43010 01 Description of Air Filtration System How the HEPAtech Air Purifier System Works As the air is pulled into the purifier the activated carbon pre filter absorbs odors and catches large particles
7. FORE USING THIS AIR PURIFIER 1 This air purifier is designed for use on a flat level floor and may not work properly on an uneven floor ALWAYS place the air purifier on a firm level floor ALWAYS place the air puri fier at least six 6 inches away from walls and heat sources such as stoves radiators or heaters 2 Place the air purifier in an area that is out of the reach of children 3 Before using the air purifier extend the cord and inspect for any signs of damage DO NOT use the product ifthe cord has been damaged 4 This product has a polarized plug one blade is wider than the other as a safety feature This plug will fit into a polarized outlet only one way Ifthe plug does not fit fully into the outlet reverse the plug Ifthe plug still does not fit contact a qualified electrician DO NOT attempt to defeat or override this safety feature 5 ALWAYS UNPLUG the air purifier while it is being cleaned 6 DO NOT move or tilt the air purifier while it is in operation Turn off and unplug before moving 7 DO NOT immerse the air purifier in water at any time because permanent damage will oc cur To properly clean your air purifier follow the instructions in the Maintenance section of this manual pg 10 READ AND SAVE ALL INSTRUCTIONS Introduction Thank you for purchasing the HEPAtech Air Purifier from Hunter Fan Company You have purchased our latest development in portable air purification which has been designed
8. Model 30721A www hunterfan com Table of Contents Safety 3 Introduction 3 Wa Description of Air Filtration System How the Air Purifier WOrks ssssssssssscccssescecsssesesssssscessssecesssseecessnscesssnsecessnssecssnseeessansesss 4 Air Purifier COMPONENMS sssssssscssssscsssscssssccssccsssccssscccsssccssueccsssccsssccesuccesssccssnecesncessees 4 Display atid Control Keys issiria siiani 5 Operation Initial Operatiounen ia e raa 6 Remote Opera iii a 8 Filter Life COMA TONS iran 9 Locking Unlocking the Keypad ssssssescsssescssescssssessseessseescsseecssseccuseessseecsseeessseecaseees 9 Resetting the Air Purifier ssssssssssessssscssssecsssscssnsccsssccssusecsssscssuscessccssuscesseeessucessees 10 Usind TINS TOMI ZE sora 10 Controlling the Backlight scssssscssecsecsssecssecssecssessssecssecssceseecssessssccseeesecesecseseesseeeses 10 qe Air Purifier Maintenance e Cleaning Your Air Purifier Changing the Changing the HEPAtech Filter eesessssesssecssecssecssscsssesssecssecssceessccscesscesscesasesseeeses 12 Obtaining Replacement Filters csessssesssesssecssessssccseecssecsecsuccsssceseecscesseesseesseeeses 14 Troubleshooting Problem and Solutions Technical SUPPO RR RR ORE 5 Warranty Information ecc 16 yer 43010 01 2 SAFETY INSTRUCTIONS IMPORTANT READ ALL INSTRUCTIONS BE
9. ON HOW LONG AN IMPLIED WARRANTY LASTS THE EXCLUSION OR LIMITATION OF DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE 17 43010 01 Other Home Comfort Products from Hunter The Care Free Programmable Humidifier Thermostat To learn more about Hunter Fan Company products please see our Web page at www hunterfan com
10. cked all keys will be disabled If you press a key the Keypad Locked Indicator will be displayed on the screen for 1 2 seconds To Lock or Unlock the Keypad 09 1 To lock the keypad press and hold the OFF SPEED and TURBO keys simultaneously for 2 3 seconds The Keypad 09 9 5 Locked Indicator will appear on the display Refer to Fig 9 After releasing the keys the Keypad Locked Indicator loD 2 amp will disappear PE 2 To unlock the key pad press and hold the OFF SPEED and TURBO keys simultaneously for 2 3 seconds The Keypad Indicator will disappear and the keypad will be functional 9 43010 01 WA Operation Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the air purifier If you still have problems after resetting the air purifier please contact Hunter for additional assistance refer to Technical Assistance pg 14 To Reset the Air Purifier 1 Unplug the unit for at least 30 seconds 2 Plug the unit back in Using the lonizer Using the ionizer improves the quality of air in the room Negative ions are released into the air and positively charged dust smoke and pollen particles are attracted to the negative ions These particles settle out of the air and can be vacuumed up during normal cleaning These particles are also more easily captured by the HEPAtech filter as they pass through the HEPAtech
11. les coming off the pre filter Those particles are part of the odor removing activated carbon and will be collected on the filter during regular use 11 43010 01 md Air Purifier Maintenance PRE FILTER HOOK TAPE HOOK TAPE Fig 11 6 Place the front grill back onto the unit First line up the tab on the bottom of the grill with the recess on the purifier base and then push the top of the grill forward until it is closed Refer to Figs 6 and 7 pg 7 NOTE This unit will not operate unless the grill is in the correct position 7 Plug in the air purifier 8 Finally reset the Pre Filter Counter by pressing the PRE FILTER RESET key for 2 seconds The Pre Filter Counter will return to 100 and the Pre Filter indicator will stop flashing Changing the HEPAtech Main Filter When the HEPAtech Main Filter exceeds 2800 hours approximately 4 to 6 months of use the HEPAtech Main Filter Indicator will turn on as a reminder that you should replace the filter Refer to Filter Life Counters for additional information pg 9 This is a reminder that you should check the filter and replace it if necessary The proper time to change the filter depends on usage and the environment Generally if you notice a decrease in air output or an increase in noise at any time during normal operation the filter may be clogged Replace the filter to return to normal operation To change the filter and reset the Filter Life
12. r to zero before it expires press and hold the HEPAtech Filter Reset Key for three seconds When the Indicator begins flashing release the Key Then once again press and hold the HEPAtech Iter 13 43010 01 f Air Purifier Maintenance Obtaining Replacement Filters To obtain replacement filters for your air purifier first determine your model number by looking at the information label on the back of the air purifier The model number will be listed on the label Then call 1 888 830 1326 CANADA 1 866 268 1936 from 7AM to 7PM Central Time Monday thru Friday and 8AM to 5PM Central Time on Saturday to order directly Or contact us over the internet at www hunterfan com to order online To ensure that you obtain the correct filters please find your model number below that specifies the correct replacement filters 43010 01 14 Problem 1 No display or operation Troubleshooting Solutions Confirm that the unit is plugged in Check the installation of the front grill Reset the air purifier See Resetting the Air Purifier on pg 10 Keypad does not work Key pad has been locked to prevent accidental changes to the programs See Keypad Lock on pg 9 to unlock the key pad Erratic Display or Opera tion HEPAtech Filter and or Pre filter Indicator is Flashing Reset the air purifier See Resetting the Air Purifier on pg 10 The HEPAtech Filter and or Pre Filter Life Counters ha
13. rifier must be unplugged during the cleaning process Be sure the unit is completely dry before plugging in and using Never immerse unit in water Changing the Pre Filter When the Pre Filter exceeds 1400 hours refer to Filter Life Counters for additional infor mation pg 9 the Pre Filter Life Counter will display 0 life remaining and the Pre Filter indicator will flash as a reminder that you should replace the pre filter To maintain proper odor removing capability and overall filtration performance the pre filter should be changed every 1400 hours approximately 3 months of use If necessary the pre filter can be changed more often Proper maintenance of the pre filter will help extend the life of the HEPAtech filter Refer to Obtaining Replacement Filters pg 14 if you need help finding replacement filters To change the Pre Filter and reset the Pre Filter Life Counter 1 First turn off and unplug the air purifier 2 Next remove the front grill Place your fingers under the handle on the grill and pull forward then up Refer to Figs 4 and 5 pg 6 3 The pre filter is attached to the inside of the grill with hook tape Pull gently on the pre filter to remove it Refer to Fig 11 pg 11 4 If needed use a soft damp cloth to wipe off the grill 5 Install the new pre filter by placing it in the grill and pressing gently on the pre filter so that it adheres to the hook tape You may notice a few black partic
14. t will not operate unless the grill is in the correct position LINE UP TAB WITH RECESS IN BASE RECESS Fig 6 Fig 7 09 6 Plug the unit into a 120V electrical outlet and press the OFF SPEED key The air o purifier will start with a low blower speed Y 09 7 Use the OFF SPEED and TURBO keys to adjust the blower speed to the desired A level Off Sleep Active Turbo Clean Refer to Fig 8 8 Use the TURBO key to adjust the blower speed to high After 1 hours the fan ail will return to the previous speed setting 90 ARA 9 48 ACTIVE 7 43010 01 WA Operation Remote Operation For your convenience a remote control is provided with this air purifier The remote may be used to turn the air purifier on or off and adjust the fan speed Operating the Air Purifier with the remote 1 Install two AAA batteries UM 4 or IEC RO3 or equivalent Refer to the graphics in the battery compartment for proper orientation of the bat teries WARNING Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries 2 To use the remote point it at the air purifier then press and release the appropriate key The key functions are as follows 9 SLEEP ACTIVE TURBO CLEAN When the keypad is locked the remote may still be used to adjust the speed or turn off the air purifier If the remote is not working properly
15. ve reached the estimated usage times Check and replace or filters if needed Refer to Changing the Pre Filter on pg 11 and Changing the HEPAtech Main Filter on pg 12 HEPAtech Filter and or Carbon Pre Filter Life Counter is flashing 0 The HEPAtech Filter and or Pre Filter Life Counters have greatly exceeded the estimated usage times Replace the corresponding filters Unit has reduced air flow or increased noise The filters are clogged and should be cleaned Refer to Changing the Pre Filter on pg 11 and Changing the HEPAtech Main Filter on pg 12 Technical Support If you have any additional questions or problems with your Hunter air purifier please call 1 888 830 1326 from 7 00AM to 7 00PM Central Time Monday thru Friday and 8 00AM to 5PM Central Time on Saturday or contact us over the Internet at www hunterfan com 15 43010 01 El Warranty 43010 01 16 Warranty 9 damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR DIRECT INDIRECT SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES IN EXCESS OFTHE PURCHASE PRICEOFTHE AIR PURIFIER YOUR SOLE REMEDY WILL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS