        Honeywell 69-2072-05 Thermostat User Manual
         Contents
1.       Advanced HVAC installer setup instructions          1  Press and hold the UP  2  Press    More    to advance to the  DOWN arrows for 3 seconds  next setup option  See table on  next page             ux   zu             24823   24824  3  Use the UP DOWN arrows to 4  Press    Done    at any time to save and  select options  See table on next return to the home screen   page    acu    z     M24825  17 69 2072   05    69 2072_C indd 17 e 7 81 2008 2 04 27 e       e    Advanced programming    To be used by qualified HVAC technician     Setup functions    Temperature Display    Settings  amp  Options  factory default in bold   1 Fahrenheit  2 Celcius       Frost Protection    OzNot installed  1            Protection OFF  2 Frost Protection ON       Humidity High Limit    596 8096 in 5  increments  40        Humidifier Operation    Programmed Humidity    OzHum only while heat        22Hum forces fan on   1zHum only while fan on  3 Hum operates indepen   dent of fan   O OFF  1            Program Start Time    Program End Time   appears only if ISU30 1     15 min increments  11 00 PM   15 min increments  7 00 AM       DEHUM Terminal  Equipment Type    OzNo Dehum  low speed vent   1 Dehum only       High Dehum Limit    3596 8095  in 5  increments       Low Dehum Limit    3594 8096 in 5  increments                      60 Dehumidifier Operation OzDehum forces fan on  1zDehum operates independent of fan   65 Humidity Display Offset Set between  5  to 5  to recalibrate humidity sens
2.   Setup functions  ASHRAE  CFM Setting    Settings  amp  Options  factory default in bold   3 30 CFM  4 40 CFM  up to 20 200 CFM       Maximum Vent    00  30  95    00 setting runs to ASHRAE 100         Vent Shut offs    OzAuto vent regardless of outdoor conditions  1      at 75  F dew point or 99  F air temp   2 Low speed at 65  F dew point or 85  F air temp  Off at  75  F dew point or 99  F air temp    Note  If option 1 or 2 is selected  then ASHRAE 62 2  Standard will not be met        Dehumidification Via  Fresh Air Ventilator       69 2072   05        69 2072 C indd 20       OzDo not use ventilation for dehum   1 Allow vent for dehum per outdoor conditions    With dehum installed  control to setpoint  Without   dehum installed  control to the Hum setpoint  10  e       20    e 7 31 2008 2 04 28 Pm        Environmental standards life expectancy    TruelAQ  Control and Outdoor Sensor   e  Operating Storage temp   40  F to  120  F   40  C to 50  C    e Condensation Protection  0 100    e Operating RH   0  to 99  non   condensing  TruelAQ   Outdoor sensor  protected from condensation    e Temp reading range   40  C to 50  C    40  F to 122  F    e Temp accuracy within range  0 4  C   0 72  F      Humidity reading range  5  to 95     e Humidity temp accurate reading range      20  C to 50  C   17  F to 122  F   e Humidity accuracy over that range    4 5   e Maximum real time clock drift over 1  year  7 minutes  Vertical mount to cover one gang box  Flame Rating  UL94V 0  RoHS 
3.   returned to the following address  Honeywell Return Goods  Dock 4 MN10 3860  1885 Douglas Dr  N   Golden Valley  MN 55422  or  whether a replacement product can be sent to you    This warranty does not cover removal or reinstallation costs  This warranty shall not apply if it is shown by Honeywell that the  defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer   Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above  HONEYWELL SHALL   NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND  INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES  RESULTING  DIRECTLY OR INDIRECTLY  FROM ANY BREACH OF ANY WARRANTY  EXPRESS OR IMPLIED  OR ANY OTHER  FAILURE OF THIS PRODUCT  Some states do not allow the exclusion or limitation of incidental or consequential damages  so this  limitation may not apply to you    THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT  THE DURATION OF ANY  IMPLIED WARRANTIES  INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE    IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS WARRANTY  Some states do not allow limitations on how long an  implied warranty lasts  so the above limitation may not apply to you    This warranty gives you specific legal rights  and you may have other rights which vary from state to state    If you have any questions concerning this warranty  please write Honeywell Customer Rela
4.  6  For duct mounting   A  snap out side wall clip and attach  as shown  Run wires through the side wall hole  under  the clip  to the terminals   B  Snap in sensor cap     7  Reinstall the front housing on the power base  and  secure with screw    Note  If duct mounted  ensure sensor cap tip aligns with   air flow in duct     8  Apply power to the system        9 69 2072   05        69 2072 C indd 9 e 7 81 2008 2 04 25 e          M24819    69 2072   05        69 2072 C indd 10    24V supply  Must be common to G output     24Vac 20  1 5  amp max       24V supply common     24Vac 20        Communication and supply bus to remote  sensors  sensor pins not polarized    Override switch input  Active when R is  applied    24Vdc 64mA max  out   24Vac 20    10mA max in       W input to sense when the thermostat is  calling for heat  Active when R is applied     24Vac 20    10mA max in       G input to sense fan calls  Active when R is  applied  Fan output to activate system fan   R8222 Isolation Relay may be required if G  is not isolated through the thermostat     24Vac 20    10mA max in  24Vac from R   1Amp max out       Dry contact output  Opens the vent  damper of an HRV or the bathroom fan  and Damper     24Vac from R   1Amp max out       Dry contact output  Starts the  Dehumidifier or an alternate fan speed     24Vac from R   1Amp max out          Dry contact output  Starts the Humidifier     10       24Vac from R   1Amp max out       7 31 2008 2 04 26 Pm          e         Wir
5. AY MAY BE REQUIRED TO    ISOLATE THE G WIRE    FOR WIRING OF HUMIDIFIER OTHER THAN THE HE265 READ THE INSTALLATION   INSTRUCTIONS    27391  14    e 7 31 2008 2 04 26 Pm           tion damper  and an auxiliary    exhaust fan         Wiring TruelAQ   with a non  TH8110U          RRcC WY     powered humidifier  ventila        TruelAQ       SENSOR OUTDOOR      Hvac  SENSOR  SENSOR  PROVIDED         69 2072 C indd 15         SWITCH           120 VOLT POWER  L2     A IF A THERMOSTAT OTHER THAN A TH5110  TH5220  TH5320  TH6110  TH6220  TH6320  TH8110  TH8320  OR TH8321 IS USED  A RELAY MAY BE REQUIRED TO ISOLATE THE G WIRE     FOR WIRING OF HUMIDIFIER OTHER THAN THE HE265 READ THE INSTALLATION INSTRUCTIONS     IF A RELAY OTHER THAN THE R8239 IS USED  A DEDICATED TRANSFORMER WITH AT LEAST 40 VA IS  REQURED TO POWER THE HE265 AND EARD  IF AN R8239 IS USED  AS SHOWN IN THIS DIAGRAM  NO  ADDITIONAL TRANSFORMER IS REQURED  M27392    15 69 2072   05    e 7 31 2008 2 04 27 e         e      Mounting the outdoor sensor    1  Do not mount on the south side of the house or in direct exposure to sunlight     2  Keep at least 4 feet away from exhaust  vents     3  If in an air intake  place 1 foot closer to  outside wall    4  Place at least 6 inches higher than  possible snow buildup    5  Do not route sensor wire near high  voltage wires        Note  The sensor can be extended using  18 gauge wire        M24821  M24822    69 2072   05 16        69 2072 Cindd 16 e 7 81 2008 2 04 27 PM          
6. DeHumidify    Set  M24834    Auto Off  DeHumidify    M24835 e    Time On  Ventilate    0020      24836       Auto On Off  Ventilate       M24837    7 31 2008 2 04 25 e               Changing time of day and service timers       1  Press    More     Adjust hour using the the UP DOWN  arrows     2  Press    More     Adjust minutes using the UP DOWN  arrows     3  Press    Done    to save settings     Service Timers  Service timers appear when the humidifier  dehumidifier   ventilator  air filter  and or UV bulbs need service  Your HVAC  technician will set these timers during installation     Resetting Service Timers    Press and hold the DOWN arrow for 5 seconds to reset your  service timers         69 2072_C indd 7 e          M24934       M24935                                   M24933  69 2072   05    7 31 2008 2 04 25 e         e      Installation  0 CAUTION  ELECTRICAL HAZARD  Can cause electrical shock or       equipment damage  Disconnect power before beginning installation     1  Turn system power off   2  Choose a location  TruelAQ  can be mounted to a wall or directly to the return duct        M24787    69 2072   05 8        69 2072 C indd 8 e 7 81 2008 2 04 25 e       e  Installation    3  Loosen the cover screw   4  Separate the front housing from the base           M24814  5  For wall mounting  run wires through  the back hole to the terminals  Wire  size for all connectors   2 x 18 AWG to 1 X 22 AWG     Install the mounting plate using two  screws        M24818   
7. Honeywell    Owner s Guide       e 23 e    TruelAQ     Digital IAQ Control    69 2072 05        69 2072 C indd 1 e 7 31 2008 2 04 24 Pm        e                                     User Information Installer Information  About TruelAQ                                 1 Installation  eit 8  Operation                     nene 2 Wiring               eese 10  Display screen reference             3 Mounting the outdoor sensor     16  Advanced programming            17    Adjusting IAQ settings  Changing humidifier settings     4   Appendices       Changing dehumidifier settings    6 Standards           Changing ventilation settings        6 Warranty information  Changing time of day                  7       Service timers    Need Help     For assistance with this product please visit http   yourhome honeywell com  or call Honeywell Customer Care toll free at 1 800 468 1502    Read and save these instructions        U S  Registered Trademark  Patents pending  Part number DG115EZIAQ   Copyright    2008 Honeywell International Inc  All rights reserved         69 2072 C indd 2 e 7 31 2008 2 04 24 Pm        e  About TruelAQ     The TruelAQ  monitors and automatically adjusts operation of your whole house humid   ifier  dehumidifier  ventilator  or bath fan     Maintaining proper indoor humidity minimizes the potential for unhealthy airborne pol   lutants to grow  Having too little humidity can leave you vulnerable to infections and  uncomfortable dry skin  Too much humidity creates idea
8. Indoor Conditions  Actual  indoor temperature and  humidity     Programmable Clock   Displays time and allows  IAQ equipment programming  based on time   Maintenance Reminders     Notifies you when your equip   ment needs service          aa Done  Saves changes     aes                                    24931       Toggle Arrows  Changes the  comfort levels of your IAQ  equipment operation       Actual outdoor temperature and humidity will only be displayed if the outdoor sensor is installed     69 2072   05        69 2072 C indd 2    2    e    7 31 2008 2 04 24 Pm        e    Display screen reference    Dry  Indoor humidity levels  are below 20  relative  humidity  RH      De Humidify  If    Humidify    is dis   played  the control is calling for  more humidity  If  DeHumidify  is  displayed  the control is calling for  humidity removal     Wet  Indoor  humidity levels are  above 6096 RH                       Window Frost  The control is  protecting your home against too  much humidity based on outdoor  conditions  Humidity levels in your  home may not reach your desired        setting as a result     Indoor temperature  and humidity     Outdoor temperature  and humidity     Ventilate  Fresh air ventilation  is on     Service Reminders  All are timer based  and will be displayed to indicate what  service is needed         69 2072 C indd 3    69 2072   05    7 31 2008 2 04 24 Pm                Changing humidifier settings    Note  These items will appear only if a humidifier 
9. compliant  Relay life  100 000 cycles at 1A 24Vac        69 2072 C indd 21    e    Power Supply       24Vac   20  50  60Hz  TruelAQ  control        24Vdc 2 wire over communication bus   not polarized  outdoor sensor    e Protected against voltage spikes   e Not protected against over voltage  connection  ex 120 or 240V    e All setup parameters are stored  indefinitely    In the Event of Power Failure  e Real time clock is maintained for 4  hours  e All outputs are deactivated  e All setup parameters are stored  indefinitely  Mechanical Design  Dimensions  2 3 4    W x 4 3 4    H x 7 8    D     TruelAQ control   2 3 4    W x 3 3 4    H x 7 8     D  Outdoor sensor    Weight   35 Ibs  TruelAQ control    15 Ibs   Outdoor sensor    Temperature Unit Display    C   F    69 2072   05    7 31 2008 2 04 28 e       e  5 year limited warranty    Honeywell warrants this product  excluding battery  to be free from defects in the workmanship or materials  under normal use and  service  for a period of five  5  years from the date of purchase by the consumer  If at any time during the warranty period the prod   uct is determined to be defective or malfunctions  Honeywell shall repair or replace it  at Honeywell s option     If the product is defective     i  return it  with a bill of sale or other dated proof of purchase  to the place from which you purchased it  or    ii  call Honeywell Customer Care at 1 800 468 1502  Customer Care will make the determination whether the product should be
10. ing  O OFF  no offset    80 Hum Service Timer 0 1 3 6 12  months continuous    69 2072   05 18        69 2072 C indd 18    e 7 31 2008 2 04 27 e       e    Advanced programming    Setup functions       Settings  amp  Options  factory default in bold                                         85 Hum Service Timer 0 1 3 6 12  months intermittent    90 Hum Water Filter Service   0 1 3 6 12  months intermittent    95 Air Filter Service Timer 0 1 3 6 12  months continuous    100 Vent Filter Service Timer   0 1 3 6 12  months continuous    105 Vent Service Type OzClean ventilation filter  1 Change ventilation filter   110 UV Bulb Service Reminder   0 6 12 24  months continuous    115 Vent Options OzNo vent installed  1 Ventilation using VENT contacts  2 Ventilation using VENT contacts for high speed and  DEHUM contacts for low speed  only if dehum not  installed   3 Ventilation using VENT contacts and DEHUM contacts  activated together  auxiliary ventilation device such as  exhaust fan    120 Vent Operation 0 Vent forces HVAC fan on  1 Vent operates independent of HVAC fan   125 Programmed Vent O OFF  1 ON   130 Program Start Time 15 min increments    appears only if ISU125 1    5 00 PM  135 Program End Time 15 min increments   appears only if ISU125 1    9 00       140 ASHRAE    of Bedrooms _  1 6 bedrooms  2  145 ASHRAE  Home s Sq Ft 10 1 000 Sq Ft  up to 50 5 000 Sq Ft                 69 2072 C indd 19    19 69 2072   05    e 7 31 2008 2 04 28 e               Advanced programming  
11. ing TruelAQ  with a non powered humidifier     TruelAQ       HE225  BYPASS    e HUMIDIFIER e    B    00       11 69 2072   05        69 2072 C indd 11 e 7 81 2008 2 04 26             Wiring TruelAQ   with    HVAC    powered humidifier             RECOMMENDED  PRESSURE  SWITCH    FACTORY  INSTALLED  JUMPER    THERMOSTAT       TruelAQ    TrueSTEAM   INTERNAL    NOTE  IF PRESSURE SWITCH IS USED  ENSURE        5 IS IN ON POSITION  M27341    69 2072   05 12    69 2072 C indd 12 e    7 31 2008 2 04 26 Pm           Wiring TruelAQ  with a dehu   midifier and ventilation damper         69 2072 C indd 13    TH8110U  RRcCW Y       TruelAQ        69   y SENSOR OUTDOOR HVAC    SENSOR SENSOR  DH90 DEHUMIDIFIER  GRAY DAMPER CONTROL   NOT USED   RED  24VAC POWER  YELLOW     PROVIDED   SWITCH  COMPRESSOR  CONTROL COMM   BLUE FAN AND     COMPRESSOR CONTROL  GREEN FAN ONLY  CONTROL     IF ATHERMOSTAT OTHER THAN    TH5110  TH5220  TH5320  TH6110     TH6220  TH6320  TH8110  TH8320 OR TH8321 IS USED  A RELAY MAY BE  REQUIRED TO ISOLATE THE G WIRE  M27390              13 69 2072   05    e 7 31 2008 2 04 26                Wiring TruelAQ  with a  humidifier and HRV ERV  ventilator     69 2072   05    69 2072 C indd 14    TH8110U                Y    CJ    TruelAQ           OUTDOOR HVAC  SENSOR   PROVIDED              ERV HRV  RED  BLACK  GREEN        24 VOLT 40VA   TRANSFORMER  L1 L2   IF ATHERMOSTAT OTHER THAN A TH5110  TH5220  TH5320  TH6110  TH6220    TH6320  TH8110  TH8320 OR TH8321 IS USED  A REL
12. is installed on your system     1  Set humidifier by pressing UP DOWN arrows     Tables below are recommended initial humidity settings based on  outdoor temperature  If window frost setting  see next page  is not  being used  the humidity setting should be adjusted manually when  outdoor conditions change     Outdoor Temp    Setting       20 F   29 C           0       18  C     20 F   7 C              If both humidifier  hum  and dehumidifier  dehum  are installed     du  Humidify    Set  M24831    Red font is  blinking on  screen     Dehum setpoint can only be equal to or higher than Hum setpoint  If equal  equipment    changeover will be at least 5  higher  dehum  or lower  hum      If not equal  changeover occurs at setpoint plus 2  RH  control   s deadband      69 2072   05 4        69 2072_C indd 4 e    7 31 2008 2 04 24 Pm            Changing humidifier settings    2  Press    More    to enter Window Frost Protection  Use the UP DOWN  arrows to set frost protection level        Window Frost    LESS HUMIDITY MORE HUMIDITY  LOOSE HOME SINGLE PANE WINDOWS TIGHT HOME TRIPLE PANE WINDOWS    1 2 3 4 5 6 7 8 9    SE  M24830    1    Humidify    On the first cold day after TruelAQ  is installed  look for condensation   24832       windows  If present  lower Frost Protection by one  Once set for your  home  Frost Protection does not need to be changed again     3  Press  More  again to enter operation style  Press the UP DOWN m  arrows to set  Humidity       Auto  runs humidifie
13. l breeding grounds for mold   mildew and dust mites  Humidified air also feels warmer in the winter  and dry air feels  cooler in the summer     TruelAQ can adjust humidity with or without dependency on HVAC equipment opera   tion  If you have both a humidifier and dehumidifier installed  the TruelAQ can automati   cally change over to the appropriate equipment based on your comfort settings and the  changing outdoor conditions     TruelAQ can also deliver fresh air with or without dependency on HVAC equipment  operation  Today s building codes require homes to be built more tightly for energy effi   ciency  but that tightness can also trap indoor air pollutants  such as cooking odors   cleaning agents  radon  and carbon dioxide monoxide  TruelAQ provides cost effective  ventilation in accordance to industry standards  In addition  the TruelAQ can be pro   grammed to deliver ventilation during set times of the day or night     1 69 2072   05        69 2072 C indd 1 e 7 31 2008 2 04 24 Pm        e    TruelAQ  can be used to control the humidity levels in your home  and control fresh air  intake in accordance to industry recommendations  ASHRAE 62 2      Comfort Settings  Feedback  on your indoor IAQ conditions     Outdoor Conditions     Actual  outdoor temperature and  humidity     Equipment Operation   Displays what equipment is  operating at a given time     More  Advances between  installed IAQ equipment control  options        _  9                                   aS     
14. r automatically according to settings   e  Off  turns the humidifier off  M24833    4  Press    Done    to save settings  or    More    to enter dehumidifier  settings     Off       5 69 2072   05        69 2072_C indd 5 e 7 31 2008 2 04 24 Pm           Changing dehumidifier and ventilation settings    Note  These items will appear only if a dehumidifier is installed  If both a humidifier  and dehumidifier are installed  these settings will appear after pushing    More    from the    humidifier operation style screen     1  Set dehumidifier by pressing the UP DOWN arrows  RH  will change  in increments of five     2  Press    More    to enter operation style  Press the UP DOWN arrows to  set     e    Auto    runs dehumidifier automatically according to your RH   settings     e    Off    turns the dehumidifier off   e 3  Press    Done    to save settings  or    More    to enter ventilation settings     Note  These items will appear only if a ventilator is installed     1  Use the UP DOWN arrows to run ventilation temporarily  Range is  from 20 to 480 minutes  in 20 minute increments     2  Press  More  again to enter operation style      Auto  runs ventilation according to installer settings   e            runs ventilation continuously     e    OFF    turns ventilation off  In this mode  ventilation will only  run if turned on by a remote switch     3  Press    Done    to save settings  or    More    to enter time settings     69 2072   05 6        69 2072 C indd 6 e    50    
15. tions  1985 Douglas Dr  Golden Valley   MN 55422 or call 1 800 468 1502  In Canada  write Retail Products ON15 02H  Honeywell Limited Honeywell Limit  e  35 Dynamic  Drive  Toronto  Ontario M1V4Z9     Automation and Control Solutions    Honeywell International Inc  Honeywell Limited Honeywell Limit  e  1985 Douglas Drive North 35 Dynamic Drive  Golden Valley  MN 55422 Toronto  Ontario   1   429    Honeywell    http   yourhome honeywell com       U S  Registered Trademark       2008 Honeywell International Inc  Printed in U S A  on recycled  Patents pending  paper containing at least 10   69 2072   05 M S  Rev  07 08 post consumer paper fibers         69 2072_C indd 22 e 7 81 2008 2 04 28 Pm        
    