Home
Homelite UT905011 Portable Generator User Manual
Contents
1. 3 090060064 2 DUMAS ne a a a VEER ERA 2 10 Botella de lubricante para motor 1 Manual del operador no se ilustra 1 A ADVERTENCIA Si hay piezas da adas o faltantes no utilice este producto sin haber reemplazado todas las piezas La inobservancia de esta advertencia podr a causar lesiones serias A ADVERTENCIA No intente modificar esta producto ni introducir accesorios no recomendados para la misma Cualquier alteraci n o modificaci n constituye maltrato y puede causar una condici n peligrosa y como consecuencia posibles lesiones corporales graves A ADVERTENCIA No intente accionar el generador antes de terminar de armarlo De lo contrario puede ocurrir un riesgo de lesiones graves HERRAMIENTAS NECESARIAS Vea la figura 4 Para armar la unidad se necesitan las siguientes herramientas no incluido o dibujado para escalar 7 16 pulg 1 2 pulg y 9 16 pulg llave de casquillo m 7 16 pulg 1 2 pulg y 9 16 pulg llave combinaci n NOTA Ponga combustible ni lubricante en el generador antes de instalar las pies soporte del armaz n et ruedas INSTALACI N DE LA SOPORTE DEL ARMAZON Vea la figura 5 E Localice los siguientes art culos 2 pies de soporte 2 tuercas 1 4 20 2 arandelas plana 2 arandelas de seguridad 2 perno 1 4 20 x 1 1 2 pulg E Ubique el generador y el pie de soporte para que los agujeros en el pie de soporte se alineen con lo
2. El incumplimiento de conectar correctamente a tierra el generador puede resultar en electrocuci n especialmente si el generador est equipado con un conjunto de ruedas El Reglamento Nacional de Electricidad exige que el generador est debidamente conectado a una tierra aprobada Comun quese con un electricista para todo lo relacionado con los requisitos de conexi n a tierra A ADVERTENCIA No permita que su familiarizaci n con este producto lo vuelva descuidado Tenga presente que un descuido de un instante es suficiente para causar una lesi n grave ADVERTENCIA No utilice ning n aditamento o accesorio no recomendado por el fabricante de este producto El empleo de aditamentos o accesorios no recomendados podr a causar lesiones graves APLICACIONES Este generador est disefiado para suministrar alimentaci n el ctrica para el funcionamiento de iluminaci n el ctrica compatible electrodom sticos herramientas y cargas de motor ANTES DE ACCIONAR LA UNIDAD E S lo utilicelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos m NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas E Coloque siempre el generador sobre una superficie firme plana PRECAUCI N Si se intenta arrancar el motor antes de haberse abastecido debidamente de lubricante podr a descomponerse el equipo VERIFICACI N Y ABASTECIMIENTO DE ACEITE Vea la figura 8 E
3. 1 1 qt Fuel VOlUME cri 6 gal Rated running watts determined by PGMA Standard G200 KNOW YOUR GENERATOR See Figure 2 The safe use of this product requires an understanding of the information on the product and in this operator s manual as well as a knowledge of the project you are attempting Before use of this product familiarize yourself with all operating features and safety rules AC CIRCUIT BREAKER The circuit breaker is provided to protect the generator against electrical overload The circuit breaker may be reset by lifting the circuit breaker reset lever AIR FILTER The air filter helps to limit the amount of dirt and dust drawn into the unit during operation CHOKE LEVER The choke lever is used when starting the engine ENGINE SWITCH The engine switch is used in combination with the recoil starter grip to start the generator It is also used to turn the generator off FUEL TANK The fuel tank has a capacity of 6 gallons GENERATOR Rated Voltage sinistre 120V 240V Rated AMPS iii indiaan aanas a 41 6A 20 8A Rated Running Watts cceeceeeeeeeeeeeeeeeeeee 5 000 W Rated Starting Watts oooooccncnnnnnccccconcccnnnnnnnnnnnnnnnnns 6 250 W Rated Frequency ennac nasarian 60 Hz DIMENSIONS A n r re 26 5 in WORM RE A a E E EE 94 2 20 in PION AR r EA a 23 in Weight nent ie 160 Ibs FUEL VALVE The flow of fuel through the generator is controlled by the position of the fuel valve GR
4. Ce manuel relate propos d instructions importantes lesquelles devraient tre suivies pendant l installation et l entretien des piles et de la g n ratrice m Ne pas brancher au circuit lectrique d un b timent moins qu un commutateur de transfert automatique n ait t correctement install par un technicien qualifi E Ne pas laisser des enfants ou personnes n ayant pas re u une formation ad quate utiliser cette unit Ne jamais mettre en marche ou faire tourner le moteur dans une zone ferm e ou partiellement ferm e L inhalation des fum es d chappement provoquent le d c s Garder les badauds enfants et animaux domestiques une distance minimum de 3 m 10 pi Porter des chaussures ou des bottes robustes et s ches Ne pas utiliser pieds nus Ne pas utiliser le g n rateur en tat de fatigue si l on est souffrant ou sous l influence de l alcool de drogues ou de m dicaments Garder toutes les parties du corps l cart des pi ces en mouvement et des parties br lantes de l outil Ne pas toucher les prises ou les fils d nud s Ne pas utiliser le g n rateur avec des cordons lectriques us s effiloch s d nud s ou autrement endommag s Laisser le moteur refroidir avant de remiser l outil et vidanger le carburant Ne pas utiliser le g n rateur dans la pluie ou la neige Remiser la g n ratrice dans un endroit bien ventil apr s avoir vider le r servoire de carburan
5. H Reinstale la tapa de relleno de aceite varilla medidora de aceite NOTA El lubricante usado debe desecharse en un sitio de desecho aprobado Si necesita m s informaci n consulte aun concesionario de aceite de la localidad MANTENIMIENTO DE LA BUJ A Vea la figura 15 La buj a debe tener el debido espacio interelectr dico y debe estar libre de dep sitos para que el motor funcione de forma correcta Para verificar E Retire la tapa de la buj a E Limpie toda la tierra presente alrededor de la base de la buj a H Retire los buj as con la llave no incluido E Inspeccione la buj a para ver si est da ada y limpiela con un cepillo de alambre antes de volver a instalarla Si el aislante est agrietado o desportillado debe reemplazarse la buj a NOTA Si va a reemplazarla utilice una de las siguientes buj as recomendadas o una equivalente NGK BR 6HS o Champion RL86C H Mida el espacio interelectr dico La separaci n correcta es 0 7 0 8 mm 0 028 0 031 pulg Para ampliar la separaci n doble con cuidado el electrodo superior de conexi n a tierra Para angostar el espacio golpee suavemente sobre una superficie dura el electrodo de tierra H Asiente en su lugar la buj a y enr squela con la mano para evitar trasroscarla H Apri tela con una llave para comprimir la arandela Si es nueva la buj a g rela 1 2 vuelta para comprimir al nivel adecuado la arandela Si va a volver a usar la buj a vi
6. capacidad de corriente amperios y potencia vatios del generador puede da ar el generador y los dispositivos el ctricos conectados al mismo Estimado W de arranque Estimado en marcha en vatios Herramienta o aparato Taladro el ctrico 1 2 HP Rociador de aire comprimido 1200 1 3 HP L mpara de trabajo de hal geno 1000 1000 de cuarzo Sierra alternativa Compresor de aire 1 HP Le 1920 Los valores de potencias en vatios indicados son aproximados Verifigue la potencia real de cada herramienta o aparato Sierra circular 184 mm 7 1 4 pulg Cepillo de juntas 152 mm 6 pulg Sierra de ingletes 254 mm 10 pulg Sierra de banco sierra radial de brazo 254 mm 10 pulg P gina 9 Espa ol CARACTER STICAS ESPECIFICACIONES DEL PRODUCTO MOTOR MUO AGS Moto Sii nee 4 tiempos OHC cadena de accionamiento Di metro interior x Carrera 75 mm x 65 mm Sistema de enfriamiento Aire forzado Relaci n de compresi n nacos 8 3 1 Sistema de arranque ococcccccccccnncnccnnnnannnnnnonannnnninnnns Retr ctil Sistema de ignici n ooconnccconiccccnncccnanccnnonannnnnanananannnnnno T C I Bujfa NGK BR 6HS o Champion RL86C Volumen de aceite de motor 1 01 1 1 cuarto Volumen de combustible 22 7 6 galones GENERADOR Voltaje nominal 120V 240V Amperaj
7. OPERATOR S MANUAL Manuel d utilisation Manual del operador 5000 WATT GENERATOR G n rateur de 5000 watts Generador 5000 watts UT905011 Series S rie UT905011 Serie UT905011 To register your Homelite product please visit http register homelite com Pour enregistrer votre produit de Homelite s il vous plait la visite http register homelite com Para registrar su producto de Homelite por favor visita http register homelite com NEUTRAL BONDED TO FRAME CONNECTEUR NEUTRE RELI AU CADRE PUNTO NEUTRO CONECTADO AL MARCO Your generator has been engineered and manufactured to our high standard for dependability ease of operation and op erator safety When properly cared for it will give you years of rugged trouble free performance DANGER You WILL be KILLED or SERIOUSLY HURT if you do not follow the instructions in this operator s manual Thank you for your purchase SAVE THIS MANUAL FOR FUTURE REFERENCE Ce g n rateur a t con u et fabriqu conform ment nos strictes normes de fiabilit de simplicit d emploi et de s curit d utilisation Correctement entretenu il vous donnera des ann es de fonctionnement robuste et sans probl me A DANGER Le non respect des instructions fournies dans ce manuel d utilisation entrainera des BLESSURES GRAVES voire MORTELLES Su generador ha sido dise ado y fabricado de conformidad con estrictas normas para brindar fiabilidad
8. Remplacement du filtre a essence Ceci ne doit tre effectu que par un centre de r parations agr NOTE l entretien doit tre effectu plus fr quemment lorsque le g n rateur est utilis dans des zones poussi reuses Lorsque le g n rateur a d pass les valeurs maximum indiqu es dans le tableau l entretien doit continuer a tre effectu selon les intervalles ou aux fr quences indiqu s Page 16 Frangais D PANNAGE PROBL ME CAUSE POSSIBLE SOLUTION Le moteur ne d marre pas Le contacteur du moteur est sur Mettre le contacteur du moteur sur ARRET marche Pas de carburant Remplir le r servoir de carburant Niveau d huile bas V rifier le niveau d huile moteur et faire appoint si n cessaire Le robinet de carburant est FERME Mettre le robinet de carburant sur ON Bougie d fectueuse encrass e ou mal Remplacer la bougie cart e Le levier d tranglement est en position Tirer le levier de l trangleur sur RUN MARCHE FERME Moteur remis sans traitement ou Vidanger le carburant et le carburateur vidange de l essence ou plein fait avec Remplir d essence fraiche un mauvais carburant Le moteur manque de puissance El ment du circuit de carburant V rifier le l ment du filtre air Nettoyer obstru s ou remplacer selon le besoin Moteur remis sans traitement ou Vidanger le carburant et le carburateur vidange de l essence ou plein fait avec Remplir d essence
9. SAE 10W 30 is recommended Always use a 4 stroke motor lubricant that meets or exceeds the requirements for API service classification SJ Page 12 English OPERATION NOTE Non detergent or 2 stroke engine lubricants will damage the engine and should not be used E Unscrew the oil cap dipstick and remove E Wipe dipstick clean and re seat in hole do not re thread E Remove dipstick again and check lubricant level Lubri cant level should fall between the hatched areas on the dipstick E lflevelis low add engine lubricant until the fluid level rises to the upper portion of the dipstick E Replace and secure the oil cap dipstick CHECKING ADDING FUEL See Figure 9 E Remove the fuel cap E Fill the fuel tank to 1 in below the top of the fuel neck E Replace and secure the fuel cap NOTE Always use unleaded gasoline with a pump octane rating of 86 or higher Never use old stale or contaminated gasoline and do not use an oil gas mixture Do nat allow dirt or water into the fuel tank Do not use E85 fuel USING FUEL STABILIZER Fuel gets old oxidizes and breaks down over time Adding a fuel stabilizer not included extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system Follow fuel stabilizer manufacturer s directions for correct ratio of stabilizer to fuel E Add stabilizer to fuel tank then fill with gasoline following previous instructions NOTE Fuel stabilize
10. air permet de limiter la quantit de poussi re et de salet p n trant dans l unit lors du fonctionnement LEVIER D ETRANGLEMENT Le levier d tranglement sert lors du d marrage du moteur INTERRUPTEUR DU MOTEUR L interrupteur du moteur est utilis avec la poign e du lanceur afin de faire d marrer la g n ratrice II peut galement tre utilis pour teindre la g n ratrice R SERVOIR DE CARBURANT Le r servoir de carburant a une contenance de 22 7 6 gallons ROBINET DE CARBURANT Le d bit de carburant par le g n rateur est contr l par la position du robinet de carburant BORNE DE TERRE La borne de terre permet d obtenir une bonne mise la terre du g n rateur pour la protection contre les chocs lectriques Consulter un lectricien local pour les exigences de mise la terre locales BOUCHON JAUGE D HUILE Retirer le bouchon de remplissage d huile pour v rifier le niveau d huile et faire l appoint selon le besoin VIS DE VIDANGE D HUILE Lors de la vidange de lubrifiant moteur la vis de vidange d huile moteur est desserr e pour permettre l huile d tre vidang e PRISES Le g n rateur est quip des prises 60 Hz puissance monophas e suivantes quatre prises de GFCI de 120 V c a 20 A et une prise de 240 V c a 30 A Elles peuvent tre utilis es pour le fonctionnement d appareils d clairage lectrique d outils et de charges de moteur ad quats P
11. demasiado bajo v rifier le niveau de lubrifiant avant chaque utilisation Le niveau de lubrifiant doit toujours se trouver dans la zone hachur e de la jauge y A WARNING MISE LA TERRE AVERTISSEMENT Le code lectrique am ricain National Electric Code requiert que le g n rateur soit mis a la terre HOT SURFACE par l interm diaire d une source de terre approuv e A AVERTISSEMENT SURFACE TRES WARNING 42 AVERTISSEMENT A ADVERTENCIA CHAUDE Product does not include ground rod or copper wire National Electric Code reguires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements Le produit ne comprend pas de piquet de terre ou de fil en cuivre Le code electrique americain National Electric Code requiert un g n rateur pour ADVERTENCIA SUPERFICIE CALIENTE une bonne mise a la terre approuv e Appeler un lectricien pour connaitre les exigences locales de mise a la terre El producto no incluye el alambre de cobre ni la barra de conexi n a tierra Los Reglamentos Nacionales de Electricidad exigen que el generador est debidamente conectado a una tierra aprobada Comuniquese con un electrista para todo lo relacionado con los requistos de conexi n a tierra AVERTISSEMENT CONCERNANT LES SURFACES BR LANTES Ne pas toucher le silencieux ou le cylindre en aluminium du moteur lls sont BR LANTS et peuvent causer de graves br lures Ne mettre aucun mat
12. Mangueras de vapor Abrazaderas de manguera Conectador de la manguera V lvula de retenci n de vapor combustible Las instrucciones por escrito para el mantenimiento y uso del sistema de control de emisiones evaporativas por el propietario deben ser facilitadas con cada equipo peque o para uso fuera de carreteras nueva P gina 20 Espa ol NOTES NOTAS Page P gina 21 Homeli 5000 WATT GENERATOR Ite G n rateur de 5000 watts Generador 5000 watts OPERATOR S MANUAL UT905011 Series MANUEL D UTILISATION S rie UT905011 MANUAL DEL OPERADOR Serie UT905011 CALIFORNIA PROPOSITION 65 A WARNING This product and substances that may become airborne from its Use may con tain chemicals including lead known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling PROPOSITION 65 DE LA CALIFORNIE AVERTISSEMENT Ce produit ainsi que les substances rejet es dans l air la suite de son utilisation peuvent contenir des produits chimiques notamment du plomb qui selon l tat de la Californie peuvent causer le cancer des anomalies cong nitales et d autres dommages au syst me reproducteur Bien se laver les mains apr s toute manipulation CALIFORNIA PROPUESTA DE LEY NUM 65 A ADVERTENCIA Este producto y sustancias que puedan llegar a ser aerotransportadas por su uso pueden contener sustancias quimicas por ejemplo plomo considera
13. de ces instructions Page 4 Fran ais SYMBOLES Les termes de mise en garde suivants et leur signification ont pour but d expliquer le degr de risques associ l utilisation de ce produit SYMBOLE SIGNAL SIGNIFICATION DANGER Indique une situation extr mement dangereuse qui si elle n est pas vit e aura pour cons quences des blessures graves voire mortelles Indique une situation potentiellement dangereuse qui si elle n est pas AVERTISSEMENT vit e aura pour cons quences des blessures graves ou mortelles Indique une situation potentiellement dangereuse qui si elle n est pas ATTENTION vit e pourrait entrainer des blessures l g res ou de gravit mod r e Sans symbole d alerte de s curit Indique une situation pouvant entrainer des dommages mat riels ATTENTION Certains des symboles ci dessous peuvent tre utilis s sur le produit Veiller les tudier et apprendre leur signification Une interpr tation correcte de ces symboles permettra d utiliser le produit plus efficacement et de r duire les risques SYMBOLE NOM D SIGNATION EXPLICATION Alerte de s curit Indique un risque de blessure potentiel ess Pour r duire les risques de blessures l utilisateur doit lire et veiller Lire le manuel d utilisation au ua a bi bien comprendre le manuel d utilisation avant d utiliser ce produit Avertissement concernant l humidit Ne pas exposer la pluie ou l humid
14. e ou si les lamelles sont endommag es II est pr f rable d utiliser une g n ratrice fixe comme source d nergie de secours pour alimenter la maison en cas de panne d lectricit Une g n ratrice portative m me correctement branch e risque une surcharge II peut en r sulter une surchauffe ou une contrainte indue sur les composantes du g n ratrice ce qui peut provoquer une d faillance de la g n ratrice Page 3 Fran ais INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT H Utiliser uniquement des pi ces de rechange et des accessoires approuv s et suivre les instructions dans la section Entretien de ce manuel L usage de pi ces non autoris es ou le non respect des instructions peut pr senter des risques de choc lectrique ou de blessures H Entretenir le produit conform ment aux instructions de ce manuel d utilisation E Inspecter le produit avant chaque utilisation pour s assurer qu il n y a pas de pi ces desserr es de fuites de carburant etc Remplacer les pi ces endommag es R GLES DE S CURIT PARTICULI RES A AVERTISSEMENT Lorsque cette g n ratrice est utilis e pour fournir de l nergie un syst me lectrique d un b timent cette g n ratrice doit tre install e par un lectricien qualifi et doit tre branch e un circuit ferm muni d un interrupteur de transfert conform ment au Code National lectrique NFPA70 La g n ratrice devra tre branch e sur
15. 3 m 10 pieds du g n rateur tout moment L unit fonctionne le mieux des temp ratures comprises entre 5 et 40 C 23 et 104 F avec une humidit relative de 90 ou moins Des modifications sp ciales pour une performance en haute altitude sont requises si le g n rateur est utilis en permanence des altitudes sup rieures 1500 m 5000 pieds Contacter le centre de r parations agr Homelite le plus proche pour plus d informations et pour faire effectuer des modifications V rifier la tension et la fr quence requises avant de brancher tout quipement lectronique sur le g n rateur Le g n rateur peut se trouver endommag si les appareils branch s ne sont pas pr vus pour fonctionner une tension gale a 10 et une fr quence gale 3 hz de celles indiqu es sur la plaque signal tique du g n rateur Pour viter tout dommage toujours brancher une charge additionnelle sur le g n rateur lorsqu un appareil circuits int gr s tel qu un t l viseur est utilis Une varistance peut tre aussi n cessaire pour certaines applications dans le cas d un ordinateur par exemple Une varistance peut tre aussi n cessaire pour certaines applications de l quipement en solide Pour l utilisation l ext rieur seulement Conserver ces instructions Les consulter fr quemment et les utiliser pour instruire les autres utilisateurs ventuels Si ce produit est pr t il doit tre accompagn
16. HM As the small off road equipment owner you are responsible for perfor mance of the required maintenance listed in your operator s manual Homelite Consumer Products Inc recommends that you retain all receipts covering maintenance on your small off road equipment but Homelite Consumer Products Inc cannot deny warranty solely for the lack of receipts As the small off road equipment owner you should however be aware that Homelite Consumer Products Inc may deny you warranty cover age if your small off road equipment or a part has failed due to abuse neglect or improper maintenance or unapproved modifications You are responsible for presenting your small off road equipment to a Homelite Consumer Products Inc distribution center or service center as soon as the problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Ifyou have a question regarding your warranty coverage you should contact Homelite Consumer Products Inc at 1 800 242 4672 DEFECTS WARRANTY REQUIREMENTS a The warranty period begins on the date the equipment is delivered to an ultimate purchaser b General Evaporative Emissions Warranty Coverage The equipment must be warranted to the ultimate purchaser and any subsequent owner that the evaporative emission control system when installed was 1 Designed built and equipped so as to conform with all applicable regulations and 2 Free from d
17. MARCHE H Mettre le contacteur du moteur sur MARCHE 1 E Tirer la poign e de d marrage rappel jusqu ce que le moteur d marre 6 fois maximum NOTE Ne pas laisser la poign e repartir brusquement en arri re apr s le d marrage La ramener doucement sa place d origine E Laisser le moteur tourner pendant 15 secondes et mettre le levier d tranglement sur RUN MARCHE ARR T DU MOTEUR Voir les figures 10 et 11 Pour arr ter le moteur dans des conditions de fonctionnement normales H Retirer toute charge du g n rateur E Fermer le robinet de carburant Mettre le contacteur du moteur sur ARR T O Pour arr ter le moteur en cas d urgence Mettre le contacteur du moteur sur ARR T O Page 13 Fran ais ENTRETIEN A AVERTISSEMENT Utiliser exclusivement des pi ces identiques a celles d origine pour les r parations L utilisation de toute autre pi ce peut cr er une situation dangereuse ou endommager le produit A AVERTISSEMENT Toujours porter une protection oculaire certifi e conforme a la norme ANSI Z87 1 Si cette pr caution n est pas prise des objets peuvent tre projet s dans les yeux et causer des l sions graves Seules les pi ces figurant sur la liste des pieces sont con ues pour tre r par es ou remplac es par l utilisateur Toutes les autre pi ces doivent tre remplac es dans un centre de r parations agr ENTRETIEN GENERAL Conserver
18. PERMITEN LIMITACIONES EN CUANTO A LA DURACI N DE UNA GARANT A IMPL CITA O LA EXCLUSI N O LIMITACI N DE LOS DA OS INDIRECTOS O CONSECUENTES POR LO QUE ES POSIBLE QUE LAS LIMITACIONES O EXCLUSIONES ANTERIORES NO SE APLIQUEN EN SU CASO C MO OBTENER UN SERVICIO DE GARANT A Para obtener el servicio de garant a Llame sin cargo al 1 800 242 4672 o escriba a Homelite Consumer Products Inc 1428 Pearman Dairy Road Anderson SC 29625 Para obtener el servicio de garant a fuera de los EE UU comun quese con el establecimiento Homelite local P gina 18 Espa ol GARANT A GARANT A LIMITADA DE MOTOR Vigente para motores comprados a Robin America Lake Zurich IL despu s del 1 de abril de 2008 Robin America Inc una divisi n de Fuji Heavy Industries Ltd a quien en este documento se le Ilamar Subaru Robin garantiza que cada nuevo motor que venda estar en condiciones de uso y servicio normales exento de defectos en materiales y mano de obra durante el per odo indicado a continuaci n y a partir de la fecha de la venta al comprador al menudeo original La obligaci n de Subaru Robin en virtud de esta Garant a Limitada habr de limitarse a la reparaci n y reemplazo a opci n de Subaru Robin de cualquiera de las piezas que despu s que se las inspeccione tengan a juicio de Subaru Robin defectos de materiales o de mano de obra Habr de ser condici n de la obligaci n de Subaru Robin en virtud de esta Ga
19. Si tiene alguna pregunta con respecto a la cobertura de la garant a debe comunicarse con Homelite Consumer Products Inc al 1 800 242 4672 REQUISITOS DE LA GARANT A DE DEFECTOS a El tiempo de garant a inicia en la fecha que el motor o equipo es entregado al comprador final b Cobertura de garant a de emisiones evaporativas general El equipo debe ser garantizado al comprador final y cualquier propietario subsecuente que cuando el sistema de control evaporativo instalado fue 1 Dise ado fabricado y equipado de conformidad con todas las normas aplicables y 2 Libre de defectos en los materiales y mano de obra que puedan causar el defecto de la parte garantizada por un tiempo de tres a os c La garant a en las piezas relacionadas con las emisiones evaporativas ser interpretada de la siguiente manera 1 Cualquier pieza garantizada que no est en el calendario para reemplazo como lo requiere el mantenimiento en las instrucciones por escrito debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Si cualquier de dichas partes fallan durante el tiempo de la cobertura de la garant a debe ser reparada o reemplazada por el fabricante que expide la garant a Cualquier dicha pieza reparada o reemplazada en virtud de la garant a debe ser garantizada por un periodo no menor al tiempo restante de la garant a Cualquier pieza garantizada que est en el calendario s lo para inspec ci n regu
20. caso de usarse equipos de estado s lido tales como un aparato de televisi n Tambi n podr a resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones por ejemplo con una computadora Tambi n podria resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido INTERRUPTOR DE CIRCUITO ACCIONADO POR FALLA DE CONEXION A TIERRA Vea la figura 1 Losrecept culos 20 A 120 V del generador est n protegidos con un interruptor de circuito accionado por falla de conexi n a tierra GFCI el cual protege contra los peligros de las corrientes desarrolladas al presentarse tal falla Un ejemplo de una corriente debida a una falla de conexi n a tierra es la que fluir a a trav s de una persona que est utilizando un aparato con aislamiento defectuoso y al mismo tiempo est en contacto con una tierra el ctrica como una parte de la plomer a suelo h medo o tierra Los receptaculos protegidos con GFCls no protegen contra cortos circuitos sobrecargas ni descargas el ctricas Los recept culos con GFCls pueden probarse con los botones TEST PRUEBA y RESET REAJUSTE Para efectuar una prueba E Oprima el bot n TEST Esto debe hacer salir el bot n Reset Reajustar E Para restablecer la corriente oprima el bot n RESET Realice mensualmente esta prueba para asegurarse del buen funcionamiento del GFCI Si se guarda a la intemperie el generador sin p
21. commutateur du moteur v lvula de combustible C Recoil starter grip manchon en lanceur rappel mango del arrancador retr ctil A Fuel valve robinet de carburant v lvula de combustible B Off arret apagado C On marche encendido A Move choke lever left to run pousser gauche le levier d tranglement pour la marche desplace izquierda la palanca del anegador para poner en marcha B Move choke lever right to start tirer droite le levier d tranglement pour d marrer desplace derecha de la palanca del anegador para arrancar A A Air filter cover couvercle du filtre air tapa del filtro de aire B Latches loquets pestillos C Filter element l ment du filtre elemento de filtro D Air filter unit unit de filtre air unidad del filtro de aire Fig 17 Fig 18 JEE 8 T 1 A Carburetor drain screw vis de vidange S du carburateur tornillo de drenaje del carburador A A Fig 19 gt lt 73 A Oil drainage bolt vis de vidange d huile lt gt y perno de drenaje de aceite ZF a B Oil cap dipstick bouchon du r servoir d huile jauge d huile tapa de relleno de aceite varilla c medidora de aceite A AK gt PEA Fa es Y A T Sm CS NSS A Fuel line conduites de carburant conducto B de combustible A Fuel line conduites de carburant conducto B Fuel filter fitre carbur
22. de calamine sur l cran du pare tincelles VIDANGE DU R SERVOIR DE CARBURANT CARBURATEUR Voir les figures 17 et 18 Afin de pr venir les d p ts de gommes dans le circuit de carburant vidanger le carburant du r servoir et du carburateur avant de le remiser VIDANGE DU R SERVOIR DE CARBURANT H Mettre le contacteur du moteur sur arr t O H Mettre le robinet de carburant sur ARRET E Retirerla conduite de carburant du petit robinet en serrant les extr mit s de l attache et en glissant la conduite pour la retirer E Installer une extr mit du tuyau de vidange sur le robinet et placer l autre extr mit dans un r cipient suffisamment large pour contenir le carburant vidang H Mettre le robinet de carburant sur MARCHE E Lorsque le carburant est vidang du r servoir fermer le robinet de carburant et r installer solidement la conduite sur le petit robinet VIDANGE DU CARBURATEUR H Mettre le contacteur du moteur sur arr t O E Mettre le robinet de carburant sur ARRET Placer un r cipient adapt sous la vis de vidange du carburateur pour recueillir le carburant desserrer la vis E Laisser le carburant se vidanger compl tement dans le r cipient E Resserrer la vis de vidange NOTE Consulter les directives d limination des d chets locales pour liminer le carburant correctement REMPLACEMENT DU FILTRE ESSENCE Voir la figure 19 Parfois le filtre essence peut s encrasser et c
23. de respaldo en su hogar Si comienza a sentirse descompuesto mareado o d bil luego de que el generador estuvo funcionando trasl dese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono A ADVERTENCIA Lea y comprenda todas las instrucciones El incumplimiento de cualquiera de las instrucciones siguientes puede causar electrocuci n incendio o intoxicaci n por mon xido de carbono lo cual puede causar la muerte o lesiones graves A ADVERTENCIA El Reglamento Nacional de Electricidad exige que el generador est conectado a una tierra aprobada Antes de utilizar la terminal de tierra consulte a un electricista calificado inspector de instalaciones el ctricas u organismo gubernamental de la localidad en lo referente a las reglas y disposiciones relacionadas con el uso deseado del generador GUARDE ESTAS INSTRUCCIONES Este manual contiene importantes instrucciones que se deben seguir durante la instalaci n y las actividades de mantenimiento del generador y las baterias No conecte la unidad al sistema el ctrico de un edificio a menos que el generador y el interruptor de transferencia se hayan instalado correctamente y que un electricista calificado haya verificado la salida de energ a el ctrica No permita que utilicen esta unidad ni os ni personas carentes de la debida instrucci n para su manejo Nunca arranque ni accione el motor dentro de un rea total o
24. de ventilaci n con aire a baja presi n que no se exceda de 25 psi E Limpie las superficies exteriores del generador con un pa o h medo REVISI N Y LIMPIEZA DEL FILTRO DE AIRE Vea la figura 13 Para obtener un desempe o apropiado y una larga vida til de la unidad mantenga limpios los filtro de aire E Suelte los pestillos en la izquierda de la tapa del filtro de aire Retire la tapa y h gala a un lado E Retire los elemento de filtro E Si el elemento de filtro est n sucios l vese con agua jabonosa tibia Enju guelo y d jelo secar E Aplique una capa delgada de lubricante a los elementos y despu s estruje para sacar aqu l E Coloque de nuevo los elemento en la unidad del filtro E Vuelva a colocar la tapa del filtro de aire et enganche para asegurarla NOTA No ponga a funcionar el generador sin los filtro de aire Se causa un desgaste acelerado del motor CAMBIO DEL LUBRICANTE DEL MOTOR Vea la figura 14 H Retire la tapa de relleno de aceite varilla medidora de aceite m Coloque un recipiente bajo el perno de drenaje de aceite para recoger el lubricant a medida que salga E Desenrosque el perno de drenaje de aceite y retirelo E Permita que se drene completamente el lubricante H Instale de nuevo el perno de drenaje de aceite y apri telo firmemente E Reabastezca de lubricante la unidad de conformidad con las instrucciones indicadas en el apartado Verificaci n y abastecimiento de lubricante
25. emisiones como se describe en una Garant a del sistema de control de emisiones incluida con este producto Por supuesto este producto tambi n incluye una garant a que no est limitada a componentes relacionados con emisiones como se describe en otra secci n de este manual del operador DERECHOS Y OBLIGACIONES DEL CONSUMIDOR SEG N LA GARANT A La Junta de Recursos Atmosf ricos de California CARB y Homelite Consumer Products Inc tienen el gusto de explicar la garant a del sistema de control de emisiones evaporativas en el modelo afio 2011 de motor pequefio para uso fuera de carreteras En California los motores nuevos que utilizan motores peque os deben dise arse fabricarse y equiparse de manera que cumplan con las rigurosas normas estatales contra la contaminaci n del aire Homelite Consumer Products Inc debe garantizar el sistema de control de emisi n evaporativa en la equipo peque o para uso fuera de carreteras durante el per odo indicado abajo siempre y cuando dicho equipo no haya sido sujetos a abuso descuido o mantenimiento indebido El sistema de control de emisi n evaporativa puede incluir piezas como tanques conductos y tapas de combustible carburadores v lvulas recipientes filtros mangueras de vapor abrazaderas conectores y otros componentes asociados Para motores de 80 cc o menos s lo el tanque de combustible est sujeto a los requisitos de la garant a del control de emisi n evaporativa de
26. est pourquoi il est n cessaire de le remplacer Pour se procurer un filtre essence de remplacement veuillez communiquer avec le service la client le de Homelite au num ro suivant 1 800 242 4672 NOTE ll est n cessaire de vider le r servoir essence avant de remplacer le filtre essence Au besoin faire fonctionner l unit jusqu ce que le r servoir soit vide ou examiner le filtre avant le remplissage Pour remplacer m R gler la vanne de carburant la position OFF Arr t H Retirer le conduit essence des deux c t s du filtre en appuyant sur les extr mit s de l agrafe de but e l aide de pinces H Retirer le conduit essence en le glissant Le remplacer par un nouveau filtre essence H R installer les conduits essence sur le nouveau filtre a essence E Tirez sur les lignes afin de s assurer qu ils sont garantis E R glerlavanne de carburant la position On Marche TRANSPORT H Mettre le contacteur du moteur sur ARR T O H Mettre le robinet de carburant sur ARRET E S assurer que le moteur et l chappement de l unit sont froids H Videz le r servoir de carburant H Ne pas faire chuter heurter ou placer l unit sous de lourds objets Page 15 Fran ais ENTRETIEN REMISAGE Lors de la pr paration du g n rateur pour le remisage laisser l appareil refroidir compl tement puis suivre les instructions ci dessous DUR E DU REMISAGE AVANT LE R
27. exponga a humedad la lluvia nin a la nieve No opere con manos o pies h medos Riesgo del incendio No agregue combustible cuando el producto est functionando si no sigue las instrucciones del Manual del operador lectriques Ne pas exposer l humidit la pluie ou la gg Exhaust contains poisonous carbon monoxide gas that can cause au l humidit Failure to properly ground generator can result in Do not expose to unconsciousness or DEATH Operate in well ventilated outdoor areas away electrocution especially if the generator is rain or use in from open windows or doors equipped with a wheel kit damp locations me na de carbone tonite qui peut Une mauvaise mise la terre du g n rateur peut Ne pas exposer causer l inconscience ou la MORT Fonctionner dans les secteurs bien causer une lectracution surtout si le g n rateur la pluie est quip d un kit de roue La omisi n de conectar a tierra adecuadamente el ventil s et ext rieurs loin d ouvre des fen tres ou des portes El escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento o MUERTE Opere en reas exteriores bien ventiladasiejos de puertas o ventanas abiertas No exponga a la lluvia ni use en lugares h medos generador puede resultar en electrocuci n especialmente di si el generador est equipado con un kit de ruedas p N Using a generator indoors CAN KILL YOU IN MINUTES Generat
28. facilidad de uso y seguridad para el operador Con el debido cuidado le brindar muchos a os de s lido y eficiente funcionamiento A PELIGRO El incumplimiento de las instrucciones en este manual del operador puede CAUSARLE LA MUERTE O LESIONARLE GRAVEMENTE Merci de votre achat CONSERVER CE MANUEL POUR FUTURE REFERENCE Le agradecemos su compra GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS See this fold out section for all of the figures referenced in the operator s manual Consulter l encart volets afin d examiner toutes les figures mentionn es dans le manuel d utilisation Consulte esta secci n desplegable para ver todas las figuras a las que se hace referencia en el manual del operador A Reset button bouton de r armement bot n de reajuste B Test button essayer le bouton bot n de prueba A Recoil starter grip poign e du d marreur rappel mango del arrancador retr ctil B Air filter filtre air filtro de aire C Choke lever levier d trangleur palanca del anegador D Handle poign e mango E Fuel cap bouchon de carburant tapa del tanque F 120 volt AC GFCI 20 amp receptacles prises de 120 V c a 20 A prot g es par le disjoncteur de fuite la terre 120 V de C A GFCI 20 A recept culos G Fuel tank r servoir de carburant tangue de combustible H AC circuit breaker disjoncteur de C A disyuntor de circuito de CA 240 volt AC 20 amp r
29. fuel tank fuel lines or carburetor sticky valves or corrosion and rust of engine parts 3 Repair required due to overheating Most often caused by overloaded or clogged or damaged or missing flywheel fan inlet air passages cooling fins or air shrouds 4 Dirt or grit related wear caused by improper air cleaner maintenance most often resulting in worn piston piston rings cylinders valves valve guides carburetor or other internal components 5 Broken or scored parts caused by low oil level dirty or improper grade of oil 6 Engine tune ups and normal maintenance service including but not limited to valve adjustment normal replacement of service items fuel and lubricating oil etc 7 Any engine which has been subject to negligence misuse accident misapplication or overspeeding 8 Any engine that has been installed repaired or altered by anyone in a manner which in Subaru Robin s sole judgment adversely affects its performance or reliability 9 Any engine which has been fitted with or repaired with parts or components not manufactured or approved by Subaru Robin which in Subaru Robin s sole judgment adversely affects its performance or reliability 10 Instances when normal use has exhausted the life of a component or an engine The customer is responsible for all transportation charges in connection with any warranty work Subaru Robin reserves the right to modify alter or improve any engines or parts wi
30. g n rateur sans le filtre air Ceci entrainerait une usure rapide du moteur VIDANGE DE LE LUBRIFIANT MOTEUR Voir la figure 14 E Retirer le bouchon la jauge d huile m Placer un r cipient sous la vis de vidange d huile pour recueillir le lubrifiant vidang e D visser et retirer la vis de vidange d huile Laisser le lubrifiant se vidanger compl tement R installer la vis de vidange d huile et bien serrer Remplir de lubrifiant en suivant les instructions de la section V rification ajout de lubrifiant E R installer le bouchon la jauge d huile NOTE Le lubrifiant us e doit tre limin e aupr s d un site approuv voir le d taillant d huile local pour plus d informations ENTRETIEN DE LA BOUGIE Voir la figure 15 L cartement de la bougie doit tre v rifi et la bougie doit tre exempte de d p ts pour que le moteur fonctionne correctement Pour v rifier E Retirer le bouchon de la bougie E Nettoyer la salet autour de la base de la bougie H Retirer la bougie l aide de la cl fournie non inclus a Inspecter la bougie pour v rifier qu elle n est pas endommag e et la nettoyer avec une brosse m tallique avant de la r installer Si l isolateur est fissur ou caill remplacer la bougie NOTE Pour le remplacement utiliser le bougie recommand es suivantes ou des bougie quivalente NGK BR 6HS ou Champion RL86C E Mesurer l cartement de la bougie L cartemen
31. into the axle until the center of the pin rests on top of the axle E Repeat with the second wheel SECURING THE HANDLE See Figure 7 Grasp the handle and lift up and back until it locks in place Make sure the handle is securely locked in place before at tempting to move the generator To collapse the handle for storage pull and hold the release pin while pushing the handle down A WARNING Do not attempt to lift the unit by the handle assembly If it is necessary to lift the generator always grasp by the frame Use proper lifting techniques to avoid back injury OPERATION DANGER Carbon Monoxide Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains high levels of carbon mon oxide CO a poisonous gas you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO mM Never use a generator inside homes garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Us ing a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick dizzy
32. lever left to the RUN position STOPPING THE ENGINE See Figures 10 11 To stop the engine under normal operating conditions E Remove any load from the generator E Turn the fuel valve to the OFF position H Put the engine switch in the OFF O position To stop the engine in an emergency situation E Put the engine switch in the OFF O position Page 13 English MAINTENANCE A WARNING When servicing use only identical replacement parts Use of any other parts may create a hazard or cause product damage A WARNING Always wear eye protection marked to comply with ANSI Z87 1 Failure to do so could result in objects be ing thrown into your eyes resulting in possible serious injury Only the parts shown on the parts list are intended to be repaired or replaced by the customer All other parts should be replaced at an authorized service center GENERAL MAINTENANCE Keep the generator in a clean and dry environment where it is not exposed to dust dirt moisture or corrosive vapors Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves etc Do not use a garden hose to clean the generator Water en tering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator To clean the unit E Use a soft bristle brush and or vacuum cleaner to loosen and remove dirt and debris E Clean air vents
33. lock washer and the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source The National Electric Code contains several practical ways in which to establish a good ground source If a steel or iron rod is used it should be at least 5 8 in diameter and if a nonferrous rod is used it should be at least 1 2 in diameter and be listed as material for grounding Drive the rod or pipe to a depth of 8 ft If a rock bottom is encountered less than 4 ft down bury the rod or pipe in a trench All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be Double Insulated It is recommended to 1 Use electrical devices with 3 prong grounded plugs 2 Use an extension cord with a 3 pole receptacle and a 3 prong plug at opposite ends to ensure continuity of the ground protection from the generator to the appliance Check and adhere to all applicable federal state and local regulations relating to grounding specifications Consult a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the generator is properly grounded Page 2 English IMPORTANT SAFETY INSTRUCTIONS A DANGER Carbon Monoxide Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains high levels of carbon mon oxide CO a poisonous gas you cannot see or smel
34. posici n OFF APAGADO E Retire el conducto de combustible de la llave de purga para ello apriete los extremos del sujetador de retenci n y separe el conducto E Instale un extremo del conducto de drenaje en la llave de purga y coloque el otro extremo en un recipiente de combustible de la suficiente capacidad para recibir el combustible drenado del tanque E Ponga la v lvula de combustible en la posici n ON ENCENDIDO E Una vez que se haya drenado todo el combustible del tanque cierre la v lvula y vuelva a instalar el conducto en la llave de purga DRENAJE DEL CARBURADOR E Ponga el interruptor del motor en OFF O APAGADO E Ponga la v lvula de combustible en la posici n OFF APAGADO M Coloque un recipiente adecuado bajo el tornillo de drenaje del carburador para recibir el combustible afloje el tornillo E Permita que se drene completamente el combustible y caiga en el recipiente E Vuelva a apretar el tornillo de drenaje NOTA Consulte las normas de desecho de residuos peligrosos de la localidad donde se encuentre para averiguar la forma correcta de desechar el combustible usado REEMPLAZO DEL FILTRO DE COMBUSTIBLE Vea la figura 19 Enalgunas ocasiones el filtro de combustible puede obstruirse y deber reemplazarse Para comprar un filtro de combustible comun quese con el centro de asistencia de Homelite al 1 800 242 4672 NOTA El tanque de combustible debe estar vac o antes de reemplazar el
35. riau inflammable ou combustible sur le chemin direct de l chappement 940680021 03 CARACT RISTIQUES LECTRIQUES TAILLE DU C BLE DU CORDON PROLONGATEUR Voir le tableau ci dessous pour v rifier que la taille de c ble des cordons prolongateurs utilis s est capable de porter la charge requise Des tailles de c bles inad quates peuvent causer une chute de tension qui peut griller l appareil et surchauffer le cordon posee A A Fil de Fil de Fil de Fil de Fil de s 600 1200 i62m 500 pieds 91 m 200 pies 61 m 200 pieds 38 m 125 pieas 1200 2400 76 m 250 pieds 46 m 150 pieds 31 m 100 pieds 15 m 50 pieds 1800 3600 46 m 150 pieds 31 m 100 pieds 20 m 65 pieds 2400 4800 53m 175 pieds 38 m 125 pieds 23m 75pieds Page 7 Fran ais CARACT RISTIQUES LECTRIQUES CHARGES DU MOTEUR LECTRIQUE Les moteurs lectriques courants en fonctionnement normal tirent jusqu six fois leur courant de fonctionnement lors du d marrage Ce tableau peut tre utilis pour estimer les watts requis pour d marrer les moteurs lectriques code G cependant si un moteur lectrique ne d marre pas ou n atteint pas sa vitesse de fonctionnement teindre imm diatement l appareil ou l outil pour viter d endommager l quipement Toujours v rifier les exigences de l outil ou de l appareil utilis par rapport la sortie nominale du g n rateur Watts r
36. situation that may result in property damage Some of the following symbols may be used on this product Please study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION A Safety Alert Indicates a potential personal injury hazard eo Read Operator s Manual To reduce the risk of injury user must read and understand operator s manual before using this product Wet Conditions Alert Do not expose to rain or use in damp locations Failure to use in dry conditions and to observe safe practices can result in electric shock Running generator gives off carbon monoxide an odorless color Toxic Fumes less poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapors are extremely flammable and explosive Fire or explosion can cause severe burns or death Hot Surface od the risk of injury or damage avoid contact with any hot To reduce the risk of serious injury avoid attempting to lift the generator alone Consult with local electrician to determine grounding requirements Ground before operation Failure to properly ground generator can result in electrocution especially if the generator is equipped with a wheel kit Electric Shock Fire Explosion Lifting Hazard Electrocution Page 5 English SYMBOLS Some of the following symbols may be used on thi
37. sur les composants du syst me d mission tel que d crit ailleurs dans ce manuel d utilisation VOS DROITS ET OBLIGATIONS DANS LE CADRE DE LA GARANTIE Le California Air Resources Board et Homelite Consumer Products Inc sont heureux de vous expliquer la garantie portant sur le syst me de contr le des missions de vapeur de carburant du groupe ann e mod le 2011 Les moteurs de petite cylindr e neufs utilis s en Californie doivent tre con us construits et quip s conform ment aux strictes r glementations antipollution de cet tat Homelite Consumer Products Inc doit garantir le syst me de contr le des missions de vapeur de carburant sur le groupe pour la p riode indiqu e ci dessus sous r serve qu il n ait pas fait l objet d un usage abusif ou d un manque d entretien Le syst me de contr le des missions peut inclure des pi ces telles que carburateurs r servoirs de carburant conduites de carburant bouchon de carburant cartouches filtres tuyaux de vapeurs colliers connecteurs et autres composants associ s Pour les moteurs de 80 cm ou moins seul le r servoir de carburant est sujet aux exigences de garantie du contr le des missions de vapeurs de carburant de cette section DUR E DE LA GARANTIE DU FABRICANT Le syst me de contr le des missions de vapeurs de carburant est garanti pour trois ans Toute pi ce de l quipement se rapportant au syst me d missions de vapeurs de carburant s av r
38. tail b Couverture de garantie g n rale des missions de vapeurs de carburant II doit tre garanti a l acheteur original et a tout propri taire suivant de cet quipement que le syst me de contr le de missions de vapeurs de carburant l installation a t 1 con u fabriqu et quip conform ment a toutes les normes applicables et 2 qu il est exempt de vices de mat riaux ou de fabrication causant la d faillance d une pi ce sous garantie pendant une p riode de trois ans c La garantie sur les pi ces relatives aux missions de vapeurs de carburant doit tre interpr t e de la fa on suivante 1 Toute pi ce de garantie qui n est pas pr vue pour un remplacement dans le cadre de l entretien requis dans les instructions crites doit tre garantie pour la dur e de garantie d finie dans la sous section b 2 Si une telle pi ce conna t une d faillance durant la p riode de garantie elle doit tre r par e ou remplac e par le fabricant offrant la garantie Une telle piece r par e ou remplac e dans le cadre de la garantie doit tre garantie pour une dur e non inf rieure la p riode de garantie restante Toute pi ce de garantie qui est uniquement pr vue pour une inspection r guli re dans les instructions crites doit tre garantie pour la p riode garantie d finie dans la sous section b 2 Une d claration dans de telles instructions crites relative au remplacement ou a
39. the current that would flow through a Page 8 English ELECTRICAL GENERATOR CAPACITY Make sure the generator can supply enough continuous run ning and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the continuous running watts of these items This l is the amount of power the generator must produce to Estimated Estimated Application Equipment Starting keep the items running See the wattage reference chart pp Run Watts Watta at right 3 Estimate how many surge starting watts you will need Emergency Home Standby Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circu j lar saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to Ro ll a Example Tool or Appliance gunana Watts Starting Watts CAUTION Do not overload the generator s capacity Exceeding the generator s wattage amperage capacity can damage the generator and or electrical devices connected to it Winda AC 1800 Jobsite ElecticDii 1 2HP 600 900 Refrigerator 2200 Aires Sprayer vae 60 120 ai Reciprocating Saw 960 10 z A ED TT Total Continuous Running Watts 3475 Plus Highest Additional Surge Watts
40. the pull rope to distribute the oil Reinstall spark plug Change engine lubricant After removal from storage E Fill with fresh gasoline MAINTENANCE SCHEDULE Before After 1st month Every 3 months Every 6 months Every year or or 20 hours of or 50 hours of or 100 hours after 300 hours each use h operation operation of operation of operation Check Engine Lubricant i T T Change EngineLubricant y y yS Check Air Filter y Clean Air Filter f Pp Change Air Fitter Check Adjust Spark Plug J CE p Replace Spark Pug Check AdjustidieSpeed corm poo poo po Clearance E pa poo Filter AAA pp Check Fuel Tube Replace Fuel Filter These items should only be carried out by an authorized service center NOTE Maintenance should be performed more frequently when generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein Page 16 English TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Engine will not start Engine switch is OFF Turn engine switch to ON No fuel Fill fuel tank Lubricant level is low Check engine lubrincant level and fill if necessary Fuel valve is OFF Turn fuel valve ON Spark plug faulty fouled or improperly Replace spark plug gapped Choke lever is in R
41. with low pressure air that does not exceed 25 psi E Wipe the exterior surfaces of the generator with a damp cloth CHECKING CLEANING AIR FILTER See Figure 13 For proper performance and long life keep air filter clean M Release latches on left side of air filter cover Remove cover and set aside E Remove the filter element E f the filter element is dirty clean with warm soapy water Rinse and let dry E Apply a light coat of engine lubricant to the element then squeeze it out E Replace the element in the air filter unit m Replace the air filter cover and latch to secure NOTE Do not run the generator without the air filter Rapid engine wear will result CHANGING ENGINE LUBRICANT See Figure 14 mH Remove the oil cap dipstick E Place a container underneath the oil drainage bolt to collect used lubricant as it drains Unscrew the oil drainage bolt and remove Allow lubricant to drain completely Reinstall the oil drainage bolt and tighten securely Refill with lubricant following the instructions in the Checking Adding Lubricant section H Reinstall the oil cap dipstick NOTE Used lubricant should be disposed of at an ap proved disposal site See your local oil retailer for more information SPARK PLUG MAINTENANCE See Figure 15 The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check M Remove the spark plug cap m Clean any di
42. 1 800 242 4672 NOTE Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up To replace E Turn the fuel valve to the OFF position m Remove the fuel line from both sides of the filter by squeezing the ends of the retaining clip with pliers Slide the fuel line off Replace with new fuel filter Reinstall fuel lines to new fuel filter Pull on lines to make sure they are secured Turn the fuel valve to the ON position TRANSPORTING Turn engine switch OFF O Turn the fuel valve to the OFF position Make sure engine and exhaust of unit is cool Empty the fuel tank Do not drop or strike unit or place under heavy objects Page 15 English MAINTENANCE STORAGE When preparing the generator for storage allow the unit to cool completely then follow the guidelines below STORAGE TIME PRIOR TO STORING Less than 2 months H Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances 2 months to 1 year Drain fuel from carburetor Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances 1 year or more Drain fuel from the carburetor Remove spark plug Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances Put a tablespoon of engine oil into the spark plug cylinder Turn the engine slowly with
43. 2200 Equals Total Generator Output Required 5675 Wattages listed are approximate Check tool or appliance for actual wattage POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding electrical loads to the generator There should be nothing connected to the generator outlets before starting its engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load Never add more loads than the generator capacity Take special care to consider surge loads in generator capacity as previously described 1 3 HP Well Pump 27 in Television Light 75 Watts Page 9 English FEATURES PRODUCT SPECIFICATIONS ENGINE Engine Type 4 Stroke OHC Chain Drive Bore x Stroke 75 mm x 65 mm Cooling Syston erdina R Forced Air Compression RatiO ito 8 3 1 Starting System Recoil Ignition SYSTEM viril EG Spark Plug NGK BR 6HS or Champion RL86C Engine Lubricant Volume
44. 7 16 po 1 2 et 5 8 po OTE Ne pas mettre du carburant ou du lubrifiant dans la g n ratrice avant d installer les supports de cadre et les roues F IXER LES SUPPORTS DE CADRE Voir la figure 5 Localiser les pi ces suivantes 2 pieds de support 2 crous 1 4 20 2 rondelles plate 2 rondelles frein 2 boulons 1 4 20 x 1 1 2 po Placer la g n ratrice et le pied de support de mani re ce que les trous du pied de support soient align s avec les trous du cadre de la g n ratrice Ins rer un boulon une rondelle plate une rondelle frein et un crou Serrer solidement l crou R p ter l op ration sur l autre support INSTALLATION DES ROUES Voir la figure 6 Les roues sont fournies pour aider d placer le g n rateur fa l endroit d sir et doivent tre install es du c t oppos la poign e Localiser les pi ces suivantes 2 essieux 2 axes de blocage 2 rondelles 2 roues Relever l extr mit du g n rateur du c t du poign e rappel suffisamment pour acc der au bas du cadre placer des cales en dessous pour obtenir un bon support Glisser ce l essieu dans le trou central de la roue Glisser une rondelle sur l essieu puis glisser l essieu dans le trou de montage de la roue tel qu illustr Ins rer une goupille d attelage pour fixer solidement en place NOTE La goupille d attelage doit tre pouss e dans l essieu jusqu ce que le centre de la goupille repose sur le
45. BLE El flujo de combustible a trav s del generador se controla por medio de la posici n de la v lvula de combustible TERMINAL DE CONEXI N A TIERRA El terminal de conexi n a tierra se utiliza para ayudar a conectar a tierra correctamente el generador como ayuda de protecci n contra descargas el ctricas Consulte con un electricista local con respecto a los requisitos de conexi n a tierra en el rea geogr fica donde se encuentre usted TAPA DE RELLENO DE ACEITE VARILLA MEDIDORA DE ACEITE Retire la tapa de relleno de aceite para revisar el nivel y a adir lubricante al generador cuando sea necesario PERNO DE DRENAJE DE ACEITE Al cambiar el lubricante de motor se afloja el perno de drenaje de aceite para permitir el drenaje del lubricante usado RECEPT CULOS El generador incorpora las siguientes tomas monofasicas de 60 Hz cuatro recept culos de 120 V y 20 A de corriente alterna y uno de 240 V y 20 A de corriente alterna Los recept culos pueden utilizarse para accionar los aparatos iluminaci n el ctrica herramientas y motores apropiados MANGO DEL ARRANCADOR RETR CTIL El mango del arrancador retr ctil se usa junto con el interruptor del motor para arrancar el motor del generador P gina 10 Espa ol ARMADO DESEMPAQUETADO Este producto requiere armarse E Corte cuidadosamente los lados de la caja y despu s retire la herramienta y cualesquier accesorios de la caja Aseg rese de que est n pr
46. D TACH E Voir la figure 3 Les articles suivants sont inclus avec le g n rateur No de Pi ce Description Qt O eue 2 2 Rondelles iii ica 2 3 Axes de blocage instaure 2 4 Pieds de SUP POM iiss cscdicsssecczctadeseeecdstvesssesessncenenes 2 5 Boulons 1 4 20 x 1 1 2 po 2 6 Rondelles plate 2 7 Rondelles FIN ssis atan ai peri 2 8 orous 1 4 20 ia 2 9 A israel sind ai aaa VEEN aaaea 2 10 Flacon de lubrifiant de moteur 1 Manuel d utilisation non illustr 1 A AVERTISSEMENT Si des pi ces manquent ou sont endommag es ne pas utiliser le produit jusqu a ce qu elles soient remplac es Le non respect de cet avertissement pourrait entrainer des blessures graves A AVERTISSEMENT Ne pas essayer de modifier ce produit ou de cr er des accessoires non recommand s pour ce produit De telles alt rations ou modifications sont consid r es comme un usage abusif et peuvent cr er des conditions dangereuses pouvant entrainer des blessures graves A AVERTISSEMENT Ne pas tenter d utiliser le g n rateur avant d avoir termin l assemblage Le non respect de cette instruction pourrait entrainer des blessures graves OUTILS N CESSAIRES Voir la figure 4 Les outils suivants non inclus ou dessin pour escalader sont n cessaires pour effectuer l assemblage 5 E N Cl douille de 7 16 po 1 2 et 5 8 po Cl mixte de
47. E Vacie el combustible y el carburador Reabastezca de gasolina fresca la unidad Compruebe el elemento de filtro de aire Limpie o reemplace segun sea necesario Vacie el combustible y el carburador Reabastezca de gasolina fresca la unidad Si el problema continua comuniquese con un centro de servicio autorizado Ponga en encendido ON el disyuntor de corriente alterna Pruebe con un dispositivo diferente Cambie a una marca diferente de gasolina y asegurese de que sea de un octanaje de 86 por lo menos Si el problema contin a comun quese con un centro de servicio autorizado Si el problema persiste despu s de probar las soluciones mencionadas arriba comuniquese con un centro de servicio autorizado para solicitar asistencia Los siguientes sintomas pueden indicar problemas que afectan el nivel de emisiones de la unidad Arranque dificil o paro del motor despu s de arrancar Marcha lenta irregular Combusti n secundaria combusti n retardada E H E Falla o retardo en la combusti n con la unidad bajo carga H E Sale humo negro del escape o consumo elevado de combustible Si encuentra cualquiera de estos s ntomas permita que inspeccionen y reparen la unidad en un centro de servicio autorizado P gina 17 Espa ol GARANT A GARANTIA LIMITADA COBERTURA DE LA GARANT A Homelite Consumer Products Inc la Compa a garantiza al comprador minorista original que este Producto Homelite
48. EMISAGE Moins d 2 mois E Vidanger l essence du r servoir et la disposer dans un r cipient adapt selon les r glements nationaux et locaux en vigueur 2 mois 1 an Vidanger le carburant du carburateur Vidanger l essence du r servoir et la disposer dans un r cipient adapt selon les r glements nationaux et locaux en vigueur 1 an ou plus Vidanger le carburant du carburateur Retirer la bougie Vidanger l essence du r servoir et la disposer dans un r cipient adapt selon les r glements nationaux et locaux en vigueur Placer une cuill re soupe d huile moteur dans le cylindre de la bougie Faire tourner lente ment le moteur avec le cordon pour r partir l huile R installer la bougie E Vidanger l huile moteur Apr s le remisage E Remplir d essence fraiche CALENDRIER D ENTRETIEN Apr s 1 4 Chaque ann e Avant p Tous les 3 mois Tous les 6 mois q mois ou 20 ou toutes les chaque ou 50 heures de ou 100 heures de LE a heures de 300 heures de utilisation A fonctionnement fonctionnement fonctionnement fonctionnement Vero Phu motesr Ooo o o changer wile moteur O Verfierlefre gir 1 Nettoyer ire aa 1 Remplacerte titre air V rifier r gler P cartement de la bougie Remplacer la bougie V rifier r glerle ralenti J V rifier r gler le jeu des soupapes Nettoyer le r servoir de carburant et le filtre V rifier le tube de carburant
49. EST et RESET R initialisation Pour tester E Appuyer surle bouton TEST Ceci doit faire sortir le bouton Reset R initialiser E Pourrestaurerl alimentation appuyer sur le bouton RESET R initialiser Effectuer ce test chaque mois pour assurer un bon fonctionnement du disjoncteur de fuite la terre Si le g n rateur est remis l ext rieur non prot g des intemp ries tester la prise du disjoncteur avant chaque utilisation CAPACIT DU G N RATEUR S assurer que le g n rateur peut fournir les watts continus de fonctionnement et de surtension d marrage suffisants pour tous les articles aliment s au m me moment Suivre ces simples tapes 1 S lectionner les articles qui seront aliment s au m me moment 2 Faire le total des watts continus de fonctionnement de ces articles Ceci correspond la somme de puissance que le g n rateur doit produire pour que ces articles puissent fonctionner Voir le tableau de r f rence de wattage droite 3 D terminer les watts de surtension d marrage n cessaires Les watts de surtension correspondent la courte pointe de puissance n cessaire pour d marrer les outils ou les appareils moteur lectriques tels que les scies circulaires ou les r frig rateurs Les moteurs ne d marrant pas tous au m me moment le total des watts de surtension peut tre d termin en ajoutant uniquement les articles au wattage de surtension suppl mentai
50. Electric Code requiert un g n rateur pour une bonne mise a la terre approuv e Appeler un lectricien pour connaitre les exigences locales de mise a la terre El producto no incluye el alambre de cobre ni la barra de conexi n a tierra Los Reglamentos Nacionales de Electricidad exigen que el generador est debidamente conectado a una tierra aprobada Comuniquese con un electrista para todo lo relacionado con los requistos de conexi n a tierra ADVERTENCIA DE SUPERFICIE CALIENTE No toque el silenciador ni el cilindro de aluminio del motor Est n muy CALIENTES y causan quemaduras graves No ponga ning n material inflamable o combustible directamente en la trayectoria de las emanaciones del escape 940680021 03 ASPECTOS EL CTRICOS CALIBRE DEL CORD N DE EXTENSI N Consulte el cuadro mostrado abajo para asegurarse de que el calibre de los cordones de extensi n que utilice puedan con la carga el ctrica requerida Los cordones de calibre insuficiente pueden causar una ca da de voltaje lo cual puede quemar el dispositivo y recalentar el cord n mismo Corriente en Longitud m xima permitida del cord n 800 600 305 m 1000 pies 183 m 600 pies 114 m 375 pies 76m 250 pies Fs 600 1200 4152 m 600 pies 91 m 200 pies 61 m 200 pies 38 m 125 pies zs 900 7800 107 meso pies 61 m 200 pies 38 m 125 pies 31 m 100 pies io 1200 2400 76m 250 pies 48 m 150 pi
51. GARANTIE L ENTRETIEN SOUS GARANTIE D CRIT PR C DEMMENT CONSTITUE LE SEUL RECOURS PR VU AUX TERMES DE LA GARANTIE L ENTREPRISE NE PEUT TRE TENUE RESPONSABLE POUR AUCUN DOMMAGE SP CIAL INDIRECT OU CONS CUTIF CERTAINS TATS ET CERTAINES PROVINCES NE PERMETTENT PAS D EXON RATION OU DE R SERVE POUR CE QUI EST DE LA COUVERTURE DES DOMMAGES DIRECTS OU CONS CUTIFS ET DE LA DUR E DE TOUTE GARANTIE IMPLICITE IL SE PEUT DONC QUE L EXON RATION PR C DENTE NE PUISSE S APPLIQUER COMMENT B N FICIER D UN ENTRETIEN SOUS GARANTIE Pour b n ficier d un entretien sous garantie composer sans frais le 1 800 242 4672 ou communiquer par crit l adresse suivante Homelite Consumer Products Inc 1428 Pearman Dairy Road Anderson SC 29625 Pour b n ficier d un entretien sous garantie l ext rieur des tats Unis veuillez communiquer avec le concessionnaire local des produits Homelite Page 18 Fran ais GARANTIE GARANTIE LIMIT E DE MOTEUR Effective pour les moteurs achet s chez Robin America Lake Zurich IL aux tats Unis apr s le 1 avril 2008 Robin America Inc une division de Fuji Heavy Industries Ltd ici Subaru Robin garantit que tout moteur neuf vendu sera d pourvu dans des conditions normales d utilisation et d entretien de vices de mat riau et de fabrication pendant une p riode r pertori e ci dessous compter de la date de vente l acheteur au d tail original L obligation de Subaru R
52. OIGN E DU D MARREUR RAPPEL La poign e du d marreur rappel est utilis e avec le contacteur du moteur pour mettre le g n rateur du moteur en marche Page 10 Fran ais ASSEMBLAGE D BALLAGE Ce produit doit tre assembl E Couper prudemment les c t s de la caisse puis sortir le machine et les accessoires de la caisse S assurer que toutes les pi ces figurant sur la liste de contr le sont incluses NOTE Cet machine est lourd et n cessite au minimum deux personnes pour tre soulev e Pour viter des probl mes lombaires soulever avec les jambes pas avec le dos et demander de l aide lorsque n cessaire A AVERTISSEMENT Ne pas utiliser le produit si en le d ballant vous constatez que des l ments figurant dans la liste des pi ces d tach es ou la liste de contr le d exp dition sont d ja assembl s Certaines pi ces figurant sur cette liste n ont pas t assembl es par le fabricant et exigent une installation Le fait d utiliser un produit qui a t assembl de fa on inad quate peut entrainer des blessures H Examiner soigneusement l unit pour s assurer que rien n a t bris ou endommag en cours de transport H Ne pas jeter les mat riaux d emballage avant d avoir soigneusement examin le produit et v rifi qu il fonctionne correctement E Si des pi ces manquent ou sont endommag es appeler le 1 800 242 4672 pour obtenir de l aide LISTE DES PI CES
53. OUND TERMINAL The ground terminal is used to assist in properly ground ing the generator to help protect against electrical shock Consult with a local electrician for grounding requirements in your area OIL CAP DIPSTICK Remove the oil fill cap to check and add lubricant to the generator when necessary OIL DRAINAGE BOLT When changing the engine lubricant the oil drainage bolt is loosened to allow old engine lubricant to be drained RECEPTACLES Your generator has the following single phase 60 Hz outlets four 120 Volt AC 20 Amp GFCI receptacles and one 240 Volt AC 20 Amp receptacle These can be used for operat ing appropriate appliances electrical lighting tools and motor loads RECOIL STARTER GRIP The recoil starter grip is used along with the engine switch to start the generator s engine Page 10 English ASSEMBLY UNPACKING This product requires assembly E Carefully cut the box down the sides then remove the machine and any accessories from the box Make sure that all items listed in the packing list are included NOTE This machine is heavy and requires a minimum of two people to lift To avoid back injury lift with your legs and not your back A WARNING Do not use this product if any parts on the Loose Parts List are already assembled to your product when you unpack it Parts on this list are not assembled to the product by the manufacturer and require customer instal lation Use of a p
54. RECAUCION No intente levantar la unidad por medio de los mangos Si fuese necesario izar el generador siempre hagalo por medio del bastidor Utilice las t cnicas apropiadas de izado para evitar lesiones en la columna FUNCIONAMIENTO A PELIGRO Mon xido de carbono Usar un generador en el interior LO MATAR EN POCOS MINUTOS Los gases de escape del generador contienen niveles altos de mon xido de carbono CO un gas venenoso que no puede verse ni olerse Si puede oler los gases de escape del generador est respirando CO Pero incluso si no puede oler los gases de escape es posible que est respirando CO E Nunca use un generador dentro de su hogar garaje s tano ni dem s espacios parcialmente encerrados En dichos espacios pueden acumularse niveles mortales de mon xido de carbono Usar un ventilador o abrir puertas y ventanas NO proporciona suficiente aire fresco S LO utilice el generador al aire libre y lejos de ventanas puertas y respiraderos abiertos Estas aberturas pueden atraer los gases de escape del generador Incluso si utiliza el generador correctamente el CO puede ingresar en su hogar SIEMPRE utilice una alarma de CO de pilas o con pilas de respaldo en su hogar Si comienza a sentirse descompuesto mareado o d bil luego de que el generador estuvo funcionando trasl dese adonde haya aire fresco INMEDIATAMENTE Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono A PELIGRO
55. Subaru Robin moins que cela ne soit par crit et sign par un officier de Subaru Robin CETTE GARANTIE ET L OBLIGATION DE SUBARU ROBIN S CI DESSOUS TIENNENT LIEU DE TOUTES LES AUTRES GARANTIES OU OBLIGATIONS EXPLICITES OU IMPLICITES Y COMPRIS LES GARANTIES DE QUALIT MARCHANDE OU D ADAPTATION UN USAGE PARTICULIER IL N Y A AUCUNE GARANTIE QUI S TENDE AU DEL DE LA PR SENTE DESCRIPTION ROBIN AMERICA NE SERA EN AUCUN CAS RESPONSABLE DE DOMMAGES DIRECTS OU INDIRECTS Page 19 Fran ais GARANTIE L NONC DE CALIFORNIA AIR RESOURCES BOARD CARB QUI SUIT S APPLIQUE SEULEMENT AUX NU M ROS DE MOD LES QUI DOIVENT SE CONFORMER AUX EXIGENCES DE CARB HOMELITE CONSUMER PRODUCTS INC D CLARATION DE GARANTIE LIMIT E SYST MES DE CONTR LE DES EMISSIONS POUR LES ETATS UNIS ET LA CALIFORNIE PETITS MOTEURS NON ROUTIERS ET HORS ROUTE Votre machine essence HOMELITE neuve est conforme aux r glementations antipollution applicables de l tat de Californie d Environment Canada et del EPA La partie relative aux vapeurs de carburant de cette garantie telle que d crite ci dessous est fournie par Homelite Consumer Products Inc Une couverture de garantie antipollution pour les autres composants relatifs au syst me d mission est fournie par le fabricant du moteur tel que d clar dans la garantie relative au syst me de contr le des missions incluse avec ce produit Ce produit inclut galement une garantie non limit e
56. UN position Move choke lever to START position Engine stored without treating or Drain fuel and carburetor Refuel with draining gasoline or refueled with bad fresh gasoline gasoline Engine lacks power Fuel element clogged Checkair filter element Clean or replace as needed Engine stored without treating or Drain fuel and carburetor Refuel with draining gasoline or refueled with bad fresh gasoline gasoline AC receptacle does not work Circuit breaker is OFF Turn ON the AC circuit breaker Item plugged in is defective Try a different item Generator makes a spark knock or An occasional light knocking or ping Switch to a different brand of gasoline pinging noise ing under heavy load is not a cause making sure that the octane rating for concern However if the knocking is 86 or higher If problem continues or pinging occurs under normal load contact your nearest authorized service at a steady engine speed the problem center may be with the brand of gasoline be ing used If problem persists after trying the above solutions contact your nearest authorized service center for assistance The following symptoms may indicate problems that will affect the emissions level of the unit Hard starting or stalling after starting Rough idle Misfiring or backfiring under load Afterburning backfiring E Black exhaust smoke or high fuel consumption If you encounter any of these symptom
57. WARRANTIES OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU HOW TO OBTAIN WARRANTY SERVICE For warranty service Call toll free 1 800 242 4672 or write to Homelite Consumer Products Inc 1428 Pearman Dairy Road Anderson SC 29625 For warranty service outside the USA please contact your local Homelite dealer Page 18 English WARRANTY LIMITED ENGINE WARRANTY Effective with engines purchased from Robin America Lake Zurich IL after April 1 2008 Robin America Inc a division of Fuji Heavy Industries Ltd herein Subaru Robin warrants that each new engine sold by it will be free under normal use and service from defects in material and workmanship for a period listed below from the date of sale to the original retail purchaser Subaru Robin s obligation under this Limited Warranty shall be limited to the repair and replace ment at Subaru Robin s option of any part or parts which upon examination is are found in Subaru Robin s judgment to have been defective in material or workmanship It shall be a condition of Subaru Robin s obligation under this Limited Warranty that Subaru Robin directly or through one of its Distributors or Service Centers authorized to service the particular engine involved receive prompt notice of any warranty claim and that the engine or the part or parts claimed to be defective be promptly de
58. a 16 Espa ol CORRECCI N DE PROBLEMAS PROBLEMA CAUSA POSIBLE SOLUCI N El motor no arranca Le falta potencia al motor No funciona el recept culo de corriente alterna El generador produce un ruido como de cascabeleo o explosiones El interruptor del motor esta en apagado OFF No hay combustible Est bajo el nivel de lubricante Est cerrada la v lvula de combustible OFF Buj a defectuosa suciao con separaci n incorrecta La palanca de anegador est en la posici n RUN FUNCIONAMIENTO El motor almacenado sin tratamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad Elemento de combustible obstruidos El motor almacenado sin tratamiento ni vaciado de gasolina o reabastecido de gasolina de mala calidad El disyuntor est en apagado OFF Est defectuoso el conectado dispositivo Un leve ruido ocasional de cascabeleo o explosiones si la carga es pesada no debe ser causa de preocupaci n No obstante si tal cascabeleo o explosiones ocurren con una carga normal a velocidad estable del motor el problema puede ser la marca de gasolina utilizada Ponga el interruptor del motor en encendido ON Llene el tanque de combustible Revise el nivel del lubricante del motor y reabast zcalo si es necesario Abra la v lvula ON Reemplace la buj a Desplace izquierda de la palanca del anegador hasta la posici n START ARRANQU
59. ada o contaminada y no utilice mezcla de aceite y gasolina No permita que entre tierra o agua en el tanque de combustible USO DE ESTABILILZADOR DE COMBUSTIBLE El combustible se hace viejo se oxida y descompone al paso del tiempo Agregando estabilizador de combustible no incluido se prolonga la vida til del combustible y se evita la formaci n de dep sitos los cuales pueden tapar el sistema del combustible Siga las instrucciones del fabricante del estabilizador de combustible en cuanto a la debida proporci n estabilizador combustible E Vierta el estabilizador en el tanque de combustible y despu s ll nelo de gasolina de conformidad con las instrucciones anteriores NOTA Pueden mezclarse el estabilizador y la gasolina antes de llenar el tanque para ello utilice una lata de gasolina u otro recipiente aprobado para combustible y ag tela suavemente para realizar la mezcla E Coloque de nuevo la tapa del tanque de combustible y aseg rela E Arranque el motor y d jelo funcionar por lo menos cinco minutos para permitir que el estabilizador trate todo el sistema de combustible COMBUSTIBLES OXIGENADOS NO USE COMBUSTIBLE E85 ANULAR SU GARANT A NOTA No est n cubiertos en la garant a los problemas de desempe o o da os al sistema de combustible producidos por el uso de un combustible oxigenado con un contenido superior a los porcentajes de alcohol o compuesto de ter se alados anteriormente Ethanol Las g
60. aisante Lors de la conception de ce produit l accent a t mis sur la s curit les performances et la fiabilit afin d en faire un outil facile utiliser et entretenir A DANGER MISE A LA TERRE DU GENERATEUR Pour r duire les risques de choc lectrique ou d lectrocution le g n rateur doit tre correctement mis la terre L crou et la borne de terre sur le cadre doivent toujours tre utilis s pour connecter le g n rateur a une source de terre adapt e La mise a la terre doit se faire avec un fil de calibre 8 Brancher la borne du fil de terre entre la rondelle de blocage et l crou puis bien serrer l crou Brancher l autre extr mit du fil une source de terre adapt e Le code lectrique am ricain contient diverses fa ons pratiques permettant d tablir une bonne source de terre Si une tige en fer ou en acier est utilis e elle doit tre d au moins 15 mm 5 8 po et si une tige non ferreuse est utilis e elle doit avoir un diam tre d au moins 12 5 mm 1 2 po et tre faite d un mat riau indiqu pour la mise la terre Introduire la tige ou le fourreau une profondeur de 2 4 m 8 pieds Si un fond rocailleux est pr sent moins de 1 2 m 4 pieds enterrer la tige ou le fourreau dans une tranch e Tous les outils et les appareils lectriques utilis s l aide de ce g n rateur doivent tre correctement mis la terre par l interm diaire d un troisi me fil ou tre doublement is
61. ant filtro de de combustible combustible Fuel valve robinet de carburant interruptor del motor Petcock petit robinet Ilave de purga Off arret apagado On marche encendido w m OO A Spark plug bougie buj a B Spark plug cap capuchon de bougie tapa de la buj a TABLE OF CONTENTS M IIntrod ction issesssinenitsnenten fa TSN OC eat nettes near aude Lente dns 2 ImportantSatety instructions crac ai idiota ar eee isa 3 4 M Specific Safety Rules rr 4 MB SYMONS PRE Se eA ede hues 5 7 M Tei tg or BEEE eee pene ne ee e e a a a r 8 9 m CALS A O 10 M Assembly messes to 11 12 E Opera ON ee en EE D R SA EE K S S 12 13 m Maintenance destin sde e inner ii ia 14 16 Troubleshooting sissie iiaeaoee ara eea aur aaa sce nel dent a 17 A oea e a tr percep e a a E EE Y PEE rer r 18 20 M Parts Ordering Service comicidad Back Page INTRODUCTION This product has many features for making its use more pleasant and enjoyable Safety performance and dependability have been given top priority in the design of this product making it easy to maintain and operate A DANGER GROUNDING THE GENERATOR To reduce the risk of shock or electrocution generator must be properly ground ed The nut and ground terminal on the frame must always be used to connect the generator to a suitable ground source The ground path should be made with 8 size wire Connect the terminal of the ground wire between the
62. ant d fectueuse sera r par e ou remplac e par Homelite Consumer Products Inc RESPONSABILIT S DU PROPRI TAIRE DANS LE CADRE DE LA GARANTIE H Le propri taire de ce groupe est tenu d effectuer les entretiens n cessaires indiqu s dans le manuel du propri taire Homelite Consumer Products Inc recommande de conserver tous les re us relatifs l entretien du groupe Toutefois Homelite Consumer Products Inc ne peut par refuser la couverture de la garantie pour l unique raison du manque de re us ou parce que tous les entretiens pr vus n ont pas t effectu s Le propri taire du groupe doit toutefois tre averti que les r parations couvertes par la garantie peuvent tre refus es par Homelite Consumer Products Inc si la d faillance du groupe ou d une pi ce est due un usage abusif la n gligence un manque d entretien ou des modifications non approuv es II est de la responsabilit du propri taire de pr senter le groupe un centre de distribution et ou d entretien Homelite Consumer Products Inc d s que le probl me apparait Les r parations sous garantie seront effectu es dans un d lai raisonnable ne d passant pas 30 jours Pour toute question concernant la couverture de garantie contacter Homelite Consumer Products Inc au 1 800 242 4672 EXIGENCES CONCERNANT LES REPARATIONS SOUS GARANTIE a La p riode de garantie commence a la date de livraison de l quipement au premier acheteur au d
63. antie limit e 2 ans Moteurs essence Subaru EA190V EA175V Priv R sidentiel Garantie limit e 3 ans Moteurs essence Subaru EA190V EA175V Commerciaux Garantie limit e 1 an La r paration ou le remplacement de toute pi ce ou pi ces dans le cadre de cette garantie limit e ne doit pas prolonger la p riode de garantie du moteur au del du terme original tel que d fini ci dessus LIMITATIONS ET EXCLUSIONS Cette garantie limit e ne s applique pas 1 Un vilebrequin pli ou cass ou aux dommages r sultants entra n s par la vibration associ e un vilebrequin pli ou cass En outre aux dommages caus s par des boulons de fixation du moteur desserr s ou des accessoires ou des lames incorrects ou d s quilibr s mont s sur le vilebrequin 2 Les r parations requises suite un stockage prolong y compris les dommages caus s par du carburant vieux ou contamin dans le r servoir de carburant les conduites de carburant ou le carburateur des soupapes gomm es ou de la corrosion et de la rouille sur les pi ces de moteur 3 R paration requise suite la surchauffe La plupart du temps suite un volant ventilateur passages d air d admission ailettes de refroidissement ou grilles de prise d air surcharg s ou bouch s ou endommag s ou manquants 4 Usure associ e la salet suite un entretien incorrect du filtre air la plupart du temps entra nant un piston des segments de piston cylin
64. anual El empleo de piezas no autorizadas o el incumplimiento P gina 3 Espa ol INSTRUCCIONES DE SEGURIDAD IMPORTANTES delas instrucciones de mantenimiento puede significar un riesgo de descarga el ctrica o de lesiones Mantenga la unidad seg n las instrucciones de mantenimiento se aladas en este manual del operador mM Inspeccione cada vez la unidad antes de usarla para ver si tiene tornillos flojos fugas de combustible etc Reemplace toda pieza da ada REGLAS DE SEGURIDAD ESPEC FICAS A ADVERTENCIA Cuando este generador se utiliza para abastecer el sistema de cableado de un edificio un electricista calificado debe instalar el generador que debe conectarse a un interruptor de transferencia como un sistema derivado independiente de conformidad con el Reglamento Nacional de Electricidad NFPA 70 El generador se conectar a trav s de un interruptor de transferencia que controla todos los conductores excepto el conductor de conexi n a tierra del equipo El bastidor del generador debe conectarse a un electrodo de conexi n a tierra aprobado Si no se a sla el generador de las l neas de alto voltaje puede causarse la muerte o lesiones a los trabajadores de dichas l neas No utilice este generador para suministrar energ a a dispositivos de soporte vital o equipos m dicos de emergencia Lasemanaciones del escape contienen mon xido de carbono un gas t xico incoloro e inodoro La inhalaci n de las
65. arburant Les instructions crites pour l entretien et l utilisation du syst me de contr le des missions de vapeur de carburant par le propri taire sont fournies avec chaque groupe neuf Page 20 Frangais NDICE DE CONTENIDO MB Introducci n ici 2 Instrucciones de seguridad importantes scort tridente 3 4 H Reglas de seguridad espec ficas siennes 4 E 111010 vda il AAA A M 5 7 E Aspectos el ctricos 00 ceeccccecesecesseeeessneecccseeessaseecssseeceaseecesueeccsaeeessueescsueeessaeesceaeeeesaseesesseessaeeessnsessseeeeeseseeessaeaesseeeesas 7 9 Caracteristicas ui iia 10 B gt i fe 6 GRR meee PR E eer ees Fe peep eer peer ee 11 12 A cena Yoke S dans REON E EARE RERA EE a ANASARE AA AEAEE ECEE REIO 12 13 M Mantenimiento cuidada 14 16 E Correcci n de problemas is cono nn nn nn nan R RR RR RR e ee RARE R RR RAR RAR RR RAR RARE R RR ee ee e RR RARE ee ete RR rrnnnn rra nrannnnnss 17 M Garanti CR EE EA SA Et ALAE ALAE EA E PE TEA LAA A E AA EGE K R S RES AZ S KEL S S 18 20 E Pedidos de piezas Servicio mociones dc a dada P g posterior INTRODUCCI N Este producto ofrece numerosas caracter sticas que hacen el uso del mismo m s placentero y agradable En el dise o de este producto se ha conferido prioridad a la seguridad al desempe o y la fiabilidad por lo cual se facilita su manejo y mantenimiento A PELIGRO CONEXION A TIERRA DEL GENERADOR Para evitar el riesgo de descarga o electrocuci n el
66. areas to avoid noise interference Operating the generator in wet conditions could result in electrocution Keep the unit dry Keep the generator a minimum of 3 feet away from all types of combustible material Do not operate generator near hazardous material Do not operate generator at a gas or natural gas filling station Do not touch the muffler or cylinder during or immediately after use they are HOT and will cause burn injury E This generator has a neutral bonded condition This means the neutral conductor is electrically connected to the frame of the machine Do not allow the generator s gas tank to overflow when filling Fill to 1 in below the top neck of the gasoline tank to allow for fuel expansion Do not cover the fuel tank cap when the engine is running Covering the fuel tank cap during use may cause engine failure and or damage to the tool Do not smoke when filling the generator with gasoline Shut down the engine and allow to cool completely before adding gasoline or lubricant to the generator Do not remove the oil dipstick or the fuel tank cap when the engine is running Pay close attention to all safety labels located on the generator Keep children a minimum of 10 feet away from the gen erator at all times The unit operates best in temperatures between 23 F and 104 F with a relative humidity of 90 or less Specific modifications for high altitude performance are needed if the generator wi
67. asolinas con un contenido de 10 de etanol por volumen comunmente conocida como E10 est aceptables La E85 no lo es PRECAUCI N Teniendo la unidad en una superficie nivelada y con el motor apagado revise el nivel de lubricante cada vez antes de usar el generador ARRANQUE DEL MOTOR Vea las figuras 10 a 12 NOTA Si el generador no est en una superficie nivelada es posible que no arranque o se apague durante su funcionamiento mM Desconecte todas las cargas del generador m Ponga la v lvula de combustible en la posici n ON ENCENDIDO E Desplace izquierda de la palanca del anegador hasta la posici n START ARRANQUE NOTA Si el motor est caliente o la temperatura es superior a los 10 C 50 F desplace derecha la palanca del anegador de la posici n RUN FUNCIONAMIENTO H Lleveel interruptor del motor ala posici n de ENCENDIDO 1 E Tiredelmango del arrancador retr ctil hasta que comience a funcionar el motor seis veces como m ximo NOTA Nopermita que el mango seretraiga violentamente despu s de arrancar regr selo suavemente a su lugar original MH Permita que el motor funcione 15 segundos y despu s desplace izquierda la palanca del anegador en la posici n RUN FUNCIONAMIENTO APAGADO DEL MOTOR Vea las figuras 10 a 11 Para apagar el motor en condiciones normales de funcionamiento mM Desconecte del generador toda carga presente E Ponga la v lvula de combustible en la posic
68. carece de defectos en material y mano de obra y acuerda reparar o reemplazar a la discreci n de la Compa a cualquier Producto defectuoso sin cargo en los siguientes per odos a partir de la fecha de la compra E Tres a os si el Producto se utiliza exclusivamente para fines personales familiares o dom sticos E Un a o si el Producto se utiliza para fines comerciales Esta garant a s lo es v lida para los Productos vendidos dentro del territorio de los Estados Unidos de Am rica el distrito de Columbia Canad M xico el Estado Libre Asociado de Puerto Rico las Islas V rgenes o Guam Esta garant a no es transferible y s lo cubre los da os derivados de defectos en material o mano de obra y no los da os causados por el uso irracional incluida la falta de mantenimiento razonable y necesario Entre los art culos que no cuentan con la cobertura de esta garant a se encuentran E Los gastos de transporte originados por el env o del producto a la Compa a o a su representante de servicio autorizado para el mantenimiento incluido en la garant a o por el env o al consumidor de productos reparados o reemplazados estos cargos corren por cuenta del comprador minorista original E Los da os causados por el maltrato los accidentes el uso indebido la negligencia la alteraci n la modificaci n los efectos de la corrosi n la erosi n el desgaste normal o las reparaciones realizadas por personas ajenas a la Compa a o a sus
69. d un centre de r paration sous garantie 7 Durant toute la p riode de la garantie du syst me de contr le des missions de vapeurs de carburant indiqu e dans la sous section b 2 le fabricant offrant la garantie doit maintenir un approvisionnement en pi ces sous garantie suffisant pour r pondre a la demande pr vue de ces pi ces Des pi ces de remplacement approuv es par le fabricant doivent tre utilis es lors de tous travaux d entretien ou de r parations dans le cadre de la garantie et doivent tre fournies sans frais pour le propri taire Une telle utilisation ne r duira pas les obligations dans le cadre de la garantie du fabricant offrant la garantie L utilisation de toute pi ce ajout e ou modifi e peut tre une cause d annulation de la r clamation de garantie conform ment a cet article Le fabricant offrant la garantie n est pas tenu dans le cadre de cet article de garantir les d faillances de pi ces sous garantie caus es par l ajout ou une modification de pi ces 10 Le fabricant offrant la garantie doit fournir tout document d crivant les proc dures et polices de garantie dans les cing jours ouvrables suivant la demande du Air Resources Board LISTE DES PIECES BENEFICIANT DE LA GARANTIE RELATIVE AUX EMISSIONS 1 R servoir de carburant Bouchon de carburant Tuyaux des carburant Boite de carbone Tuyaux des vapeur Colliers de la tuyau Connecteurs de la tuyau Clapet antiretour de vapeur c
70. das por el estado de California como causantes de cancer defectos de nacimiento u otras alteraciones reproductivas Lavese las manos despu s de utilizar el aparato Lavese las manos despu s de utilizar el aparato 988000 481 1 26 11 REV 01 SERVICE For parts or service contact your nearest Homelite authorized service dealer Be sure to provide all relevant information when you call or visit For the loca tion of the authorized service dealer nearest you please call 1 800 242 4672 or visit us online at www homelite com REPAIR PARTS The model number of this product is found on a plate or label attached to the housing Please record the serial number in the space provided below MODEL NO SERIAL NO DEPANNAGE Pour tout entretien ou r paration du produit contacter le centre de r parations Homelite agr le plus proche Veiller a fournir toutes les informations pertinentes lors de tout appel t l phonique ou visite Pour obtenir l adresse du centre de r parations agr le plus proche t l phoner au 1 800 242 4672 ou visiter notre site www homelite com PIECES DE RECHANGE Le num ro de mod le se trouve sur une plaquette ou tiquette plac e sur le b ti Noter le num ro de s rie dans l espace ci dessous NUMERO DE MODELE NUMERO DE SERIE SERVICIO Para obtener piezas o servicio comuniquese con el centro de servicio autorizado de Homelite mas cercano Asegurese de proporcionar todos los da
71. de marque Homelite est exempt de tout vice de mat riau ou de fabrication et s engage r parer ou remplacer discr tion tout produit s av rant d fectueux au cours des p riodes indiqu es ci dessous compter de la date d achat E Trois ans sur les produits utilis s uniquement par des particuliers E Un an sur les produits des fins d utilisation professionnelle ou commerciale Cette garantie s applique uniquement aux produits vendus aux tats Unis dans le district f d ral de Columbia au Canada au Mexique a Puerto Rico dans les les Vierges ou Guam Cette garantie n est pas transf rable et ne couvre pas les dommages attribuables des vices autres que les vices de mat riau ou de fabrication ou les dommages li s une utilisation abusive ce qui inclut l omission de faire subir au produit un entretien raisonnable Les l ments suivants ne sont pas couverts par la garantie H Les frais de transport requis pour envoyer le produit l entreprise ou son repr sentant autoris du service la client le en vue de proc der l entretien sous garantie du produit ou pour r exp dier le produit au client la suite de sa r paration ou de son remplacement Il incombe l acheteur original d assumer ces frais E Les dommages attribuables une utilisation abusive un accident une mauvaise utilisation de la n gligence une modification aux effets de la corrosion ou de l rosion l usure normale
72. dessus de l essieu R p ter la proc dure pour l autre roue Page 11 Fran ais ASSEMBLAGE FIXER LA POIGN E Voir la figure 7 Saisir la poign e la soulever et la tirer vers l arri re jusqu ce qu elle se bloque en place S assurer que la poign e est verrouill e solidement en place avant de tenter de d placer la g n ratrice Pour replier la poign e aux fins d entreposage tirer sur la goupille de d verrouillage et la tenir ainsi tout en poussant la poign e vers le bas A AVERTISSEMENT Ne pas tenter de lever l unit par la poign e Si le g n rateur doit tre lev toujours le saisir par le cadre Utiliser les techniques de levage appropri es pour viter les blessures du dos UTILISATION A DANGER Monoxyde de Carbone Utiliser une g n ratrice a l int rieur d un b timent CAUSERA LA MORT EN QUELQUES MINUTES Le tuyau d chappement de la g n ratrice contient un niveau lev de monoxyde de carbone CO lequel s av re tre un gaz poison inodore et invisible Si vous pouvez sentir les gaz du tuyau d chappement de la g n ratrice vous respirez du CO Mais m me si vous ne pouvez pas sentir les gaz provenant du tuyau d chappement vous pourriez tre en train de respirer du CO E Ne jamais utiliser une g n ratrice l int rieur d une maison des garages des petits espaces ou au tres aires restreintes partiellement ferm es Des niveaux mortels de monoxyde de carbone peuv
73. doit se trouver dans la zone hachur e de la jauge E Si le niveau est bas ajouter de le lubrifiant moteur jusqu ce que le niveau atteigne la portion sup rieure sur la jauge E R installer et serrer le bouchon d huile la jauge V RIFICATION AJOUT DE CARBURANT Voir la figure 9 H Retirer le bouchon du r servoir de carburant E Remplir le r servoir de carburant 25 mm 1 po en dessous du haut du goulot du r servoir de carburant E Replacer et serrer le bouchon NOTE Toujours utiliser de l essence sans plomb avec un indice d octane de 86 ou plus Ne jamais utiliser du carburant vieux vent ou contamin et ne pas utiliser de m lange lubrifiant carburant Ne pas laisser la poussi re ou l eau p n trer dans le r servoir de carburant Ne pas utiliser le carburant E85 UTILISATION DE STABILISATEUR DE CARBURANT Le carburant d fraichit s oxyde et se d grade avec le temps L ajout de stabilisateur de carburant allonge la dur e d utilisation du carburant et permet d viter la formation de d p ts pouvant obstruer le circuit de carburant Suivre les instructions du fabricant de stabilisateur de carburant pour le rapport stabilisateur carburant correct H Ajouter le stabilisteur dans le r servoir de carburant puis remplir d essence en suivant les instructions donn es pr c demment NOTE Le stabilisateur de carburant et l essence peuvent tre m lang s avant le remplissage en utilisant un jerrican
74. dres soupapes guides de soupape carburateur ou autres composants internes us s 5 Des pi ces cass es ou ray es caus es par un niveau bas d huile une huile sale ou de grade incorrect 6 Mises au point du moteur et service d entretien normal y compris mais sans s y limiter r glage de soupape remplacement normal d articles de service carburant et huile de graissage etc 7 Tout moteur qui a t sujet la n gligence au mauvais usage aux accidents mauvaises applications ou exc s de vitesse 8 Tout moteur qui a t install r par ou modifi par quiconque d une mani re qui au jugement exclusif de Subaru Robin nuit sa performance et sa fiabilit 9 Tout moteur qui a t quip de pi ces ou composants non fabriqu s ou approuv s par Subaru Robin ou r par avec de tels com posants que Subaru Robin consid re de son seul jugement nocifs sa performance ou sa fiabilit 10 Cas o une utilisation normale est venue bout de la durabilit d un composant ou d un moteur Le client est responsable de tous les frais de port se rapportant au travail sous garantie Subaru Robin se r serve le droit de modifier changer ou am liorer des moteurs ou pi ces sans encourir d obligation de modifier ou remplacer les moteurs ou pi ces vendus pr c demment sans une telle modification alteration ou am lioration Nul n est autoris accorder d autre garantie ou d assumer des obligations suppl mentaires au nom de
75. e nominal 41 6A 20 8A Potencia nominal en marcha en vatios 5 000 W Potencia nominal en arranque en vatios 6 250 W Frecuencia nominal 60 Hz DIMENSIONES Longitud siseses egr 673 1 mm 26 5 pulg ANCHO sitas 508 mm 20 pulg AURA ae 584 2 mm 23 pulg PESO ssl seine RR eleda 72 6 kg 160 Ib Potencia nominal en marcha en vatios determinado por el estandar de PGMA G200 FAMILIARICESE CON EL GENERADOR Vea la figura 2 El uso seguro que este producto requiere la comprensi n de la informaci n impresa en el producto y en el manual del operador as como ciertos conocimientos sobre el proyecto a realizar Antes de usar este producto familiaricese con todas las caracter sticas de funcionamiento y normas de seguridad DISYUNTOR El disyuntor se proporciona para proteger al generator contra sobrecarga el ctrica El disyuntor puede ser reajustado levantando la palanca del disyuntor FILTRO DE AIRE El filtro de aire ayuda a limitar la cantidad de tierra y polvo que penetra a la unidad durante el funcionamiento PALANCA DEL ANEGADOR La palanca del anegador se emplea al arrancar el motor INTERRUPTOR DEL MOTOR El interruptor del motor se utiliza en combinaci n con el mango del arrancador retr ctil para arrancar el generador Adem s se utiliza para apagar el generador TANQUE DE COMBUSTIBLE El tanque de combustible tiene una capacidad de 22 7 L 6 galones V LVULA DE COMBUSTI
76. eceptacle prise de 240 volt c a 20 A 240 V de ca 20 A receptaculo J Ground terminal borne de terre terminal de conexi n a tierra K Oil cap dipstick bouchon jauge d huile relleno de aceite varilla medidora de aceite L Oil drainage bolt vis de vidange d huile perno de drenaje de aceite M Engine switch commutateur du moteur interruptor del motor N Muffler silencieux silenciador 1 G B N N SS D A Socket wrench cl douille llave de casquillo B Combination wrench cl mixte llave de combinaci n A Bolt boulon perno B Frame cadre armaz n C Frame support with foot support de cadre avec pied soporte del armaz n con pie D Flat washer rondelle plate arandela plana E Lock washer rondelle frein arandela de seguridad F Nut crou tuerca A Axle essieu eje B Wheel roue rueda C Frame cadre armaz n D Flat washer rondelle plate arandela plana E Hitch pin goupille de s ret pasador del enganche A Oil cap dipstick bouchon du r servoir d huile jauge d huile tapa de relleno de aceite varilla tapa de relleno de aceite varilla medidora de aceite B Oil fill hole orifice de remplissage d huile agujero de llenado de aceite bouchon de carburant tapa del tanque de combustible B Fuel tank r servoir de carburant tanque de A Fuel valve robinet de carburant interruptor B Engine switch
77. ed parts SPECIFIC SAFETY RULES A WARNING When this generator is used to supply a building wiring system generator must be installed by a quali fied electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70 National Electrical Code The generator shall be connected through a transfer switch that switches all conductors other than the equipment grounding con ductor The frame of the generator shall be connected to an approved grounding electrode Failure to isolate the generator from power utility can result in death or injury to electric utility workers Do not use this generator to provide power for emergency medical equipment or life support devices Exhaust contains poisonous carbon monoxide a color less odorless gas Breathing exhaust can cause loss of consciousness and can lead to death If running in a confined or partially enclosed area the air may contain a dangerous amount of carbon monoxide To keep ex haust fumes from building up always provide adequate ventilation Always use a battery powered carbon monoxide detec tor when running the generator If you begin to feel sick dizzy or weak while using the generator shut it off and get to fresh air immediately See a doctor You may have carbon monoxide poisoning Place the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated from working
78. efects in materials and workmanship that cause the failure of a warranted part for a period of three years c The warranty on evaporative emissions related parts will be interpreted as follows 1 Any warranted part that is not scheduled for replacement as re quired maintenance in the written instructions must be warranted for the warranty period defined in subsection b 2 If any such part fails during the period of warranty coverage it must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced under the warranty must be warranted for a time not less than the remaining warranty period Any warranted part that is scheduled only for regular inspection in the written instructions must be warranted for the warranty period defined in subsection b 2 A statement in such written instructions to the effect of repair or replace as necessary will not reduce the period of warranty coverage Any such part repaired or replaced under warranty must be warranted for a time not less than the remaining warranty period 3 Any warranted part that is scheduled for replacement as reguired maintenance in the written instructions must be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part must be repaired or replaced by the manufacturer issuing the warranty Any such part repaired or replaced und
79. eja g rela de 1 8 a 1 4 de vuelta para comprimir al nivel adecuado la arandela NOTA Sino se aprieta debidamente la buj a se calienta mucho y podr a da ar el motor P gina 14 Espa ol MANTENIMIENTO LIMPIEZA DEL ORIFICIO DE ESCAPE Y DEL SILENCIADOR Seg n sea el tipo de combustible empleado el tipo y cantidad de lubricante empleado as como las condiciones de funcionamiento puede obstruirse el orificio de escape y el silenciador con dep sitos de carbono Si observa alguna p rdida de potencia en la productos con motor de gasolina quiz sea necesario eliminar dichos dep sitos para restablecer el desempe o original Recomendamos enf ticamente que este servicio lo realicen nicamente t cnicos de servicio calificados PARACHISPAS Vea la figura 16 E Revise si el parachispas tiene rasgaduras o agujeros Reempl celo si es necesario Para adquirir un parachispas de repuesto comun quese con el Centro de asistencia al cliente de Homelite llamando al 1 800 242 4672 H Utilice un cepillo para retirar los dep sitos de carbono de la rejilla del parachispas DRENAJE DEL TANQUE DEL COMBUSTIBLE Y DEL CARBURADOR Vea las figuras 17 y 18 Para evitar los dep sitos de sustancias gomosas en el sistema de combustible vac e el tanque de combustible y el carburador antes de guardarlo DRENAJE DEL TANQUE DE COMBUSTIBLE E Ponga el interruptor del motor en OFF O APAGADO E Ponga la v lvula de combustible en la
80. el reabastecimiento AROE P sn a Ree g 5 i d Riesgo de incendio Revise si hay alg n derrame o fuga de combustible Apague el de combustible para evitar que el calor del silenciador encienda los motor antes de poner combustible 940974007 04 vapores de combustible ADVERTENCIA DEL LUBRICANTE DE MOTOR Antes de utilizar el generador debe abastecerlo de oats ie E en Lon eE LE KON CONE n F e t arr tera si le ni ifiant lubricante El tanque de aceite tiene una capacidad de 1 0 I A pa A 1 1 cuartos Antes de utilizar la unidad revise el nivel de lubricante RICE BA D TER El nivel de lubricante siempre debe estar entre las reas cubierta seedeet EEE EE EE nain con rayas entrecruzadas de la varilla de nivel La unidad est equipada de un sensor el A WARNING cual apaga automaticamente el motor si el nivel de lubricante desciende abajo del limite de seguridad HOT SURFACE ADVERTENCIA ACERCA DE LA CONEXION A TIERRA AVERTISSEMENT El Reglamento Nacional de Electricidad exige que el generador est conectado a una SURFACE TRES tierra aprobada CHAUDE AWARNING A AVERTISSEMENT ADVERTENCIA ADVERTENCIA Product does not include ground rod or copper wire National Electric Code requires generator to be properly grounded to an approved earth ground SUPERFICIE Call an electrician for local grounding requirements CALIENTE Le produit ne comprend pas de piquet de terre ou de fil en cuivre Le code electrique americain National
81. emanaciones del escape puede causar la p rdida de la conciencia e incluso la muerte Si se utiliza la unidad en un rea total o parcialmente cerrada el aire puede contener una cantidad peligrosa de mon xido de carbono Para evitar la acumulaci n de las emanaciones del escape siempre aseg rese de que que haya ventilaci n suficiente Siempre use un detector de mon xido de carbono de bater as al utilizar el generador Si comienza a sentirse mal mareado o d bil al estar utilizando el generador ap guelo y respire aire fresco de inmediato Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono Coloque el generador en una superficie estable horizontal con una pendiente no mayor de 4 Utilice la unidad en un rea bien ventilada e iluminada aislada de las reas de trabajo para evitar la interferencia del ruido Si se utiliza el generador en condiciones h medas puede causarse una electrocuci n Mantenga seca la unidad Mantenga el generador a una distancia m nima de 910 mm 3 pies de todo tipo de material combustible No utilice el generador cerca de materiales peligrosos No utilice el generador en una estaci n de abastecimiento de gasolina o gas natural No toque el silenciador ni el cilindro durante el funcionamiento de la unidad ni inmediatamente despu s est n CALIENTES y causan lesiones por quemadura Este generador tiene un punto neutro conectado a tierra Esto significa que el conductor neut
82. ent s accumuler dans ces aires restreintes Utiliser un ventilateur ou ouvrir une fen tre ou les portes NE fournie PAS assez d air frais respirer Utilisez SEULEMENT la g n ratrice l ext rieur et loin des fen tres ouvertes des portes ouvertes et des bouches d a rations Ces ouvertures peuvent tirer l air provenant du tuyau d chappement M me si vous utilisez une g n ratrice correctement des gaz CO peuvent toujours s infiltrer dans la maison TOUJOURS utiliser une alarme de monoxyde de carbone piles dans votre maison Si vous ressentez que vous commencez tre tourdi ou faible suite au fonctionnement de la g n ratrice allez prendre l air frais IMM DIATEMENT Consultez un m decin Vous pourriez avoir un empoisonnement au monoxyde de carbone A DANGER Une mauvaise mise a la terre du g n rateur peut causer une lectrocution surtout si le g n rateur est quip d un kit de roues Le code lectrique am ricain National Electric Code requiert un g n rateur correctement mis a la terre a une source de terre approuv e Appeler un lectricien pour connaitre les exigences locales de mise a la terre A AVERTISSEMENT La familiarit avec l appareil ne doit pas faire oublier la vigilance Ne pas oublier qu une fraction de seconde d inattention peut entrainer des blessures graves A AVERTISSEMENT N utiliser ni accessoires ni outils non recommand s par le fabricant de ce produit L
83. equis pour le d marrage du moteur 850 1200 850 2050 2400 ATTENTION V rifier la tension et la fr quence requises avant de brancher tout quipement lectronique sur le g n rateur Le g n rateur peut se trouver endommag si les appareils branch s ne sont pas pr vus pour fonctionner une tension gale 10 et une fr quence gale 3 hz de celles indiqu es sur la plaque signal tique du g n rateur Pour viter tout dommage toujours brancher une charge additionnelle sur le g n rateur lorsqu un appareil circuits int gr s tel qu un t l viseur est utilis Une varistance peut tre aussi n cessaire pour certaines applications de l quipement en solide DISJONCTEUR DE FUITE LA TERRE Voir la figure 1 Les prises de 20 A 120 V sur le g n rateur sont prot g es par un disjoncteur de fuite la terre qui prot ge des dangers de courants de d faut la terre Un exemple de courant de d faut la terre est le courant qui passerait par une personne utilisant un appareil dont l isolation serait d fectueuse et qui serait en m me temps en contact avec une mise lectrique la terre telle qu un dispositif de plomberie un sol mouill ou la terre Les prises prot g es par un disjoncteur de fuite la terre ne prot gent pas des court circuits des surcharges et des chocs lectriques Les prises prot g es par un disjoncteur de fuite la terre peuvent tre test es au moyen des boutons T
84. er warranty must be warranted for a time not less than the remainder of the period prior to the first scheduled replacement point for the part 4 Repair or replacement of any warranted part under the warranty provisions of this article must be performed at no charge to the owner at a warranty station 5 Notwithstanding the provisions of subsection 4 above warranty services or repairs must be provided at distribution centers that are franchised to service the subject eguipment 6 The owner must not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective provided that such diagnostic work is performed at a warranty station 7 Throughout the evaporative emission control system s warranty period set out in subsection b 2 the manufacturer issuing the warranty must maintain a supply of warranted parts sufficient to meet the expected demand for such parts 8 Manufacturer approved replacement parts must be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of the manufacturer issuing the warranty 9 The use of any add on or modified parts will be grounds for disal lowing a warranty claim made in accordance with this article The manufacturer issuing the warranty will not be liable under this Article to warrant failures of warranted parts caused by the use of an add on o
85. es 31 m 100 pies _15 m 60 ples is 1800 8600 c a6m150pes 31mt00pes 20 m 65pes sn 20 2400 4800 samuzspen 38 m 125 pies mose 8600 7200 26m i25 pies 20m 6pes _ so 4800 0600 ermeowe P gina 7 Espanol ASPECTOS EL CTRICOS CARGAS DE MOTORES EL CTRICOS Es caracter stico en el funcionamiento normal de los motores el ctricos comunes consumir durante el arranque hasta seis veces su corriente de operaci n Esta tabla puede emplearse para estimar la potencia necesaria en vatios para arrancar los motores el ctricos de C digo G no obstante si un motor el ctrico no arranca o no alcanza la velocidad de funcionamiento apague el dispositivo o herramienta de inmediato para evitar da ar el equipo Siempre verifique los requisitos de la herramienta o aparato con la salida nominal del generador Potencia necesaria para arrancar el motor vatios PRECAUCI N Capacitor Fase dividida 850 1200 850 2050 2400 El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador Pueden ocurrir da os si el equipo no est dise ado para operar dentro de una variaci n de voltaje de 10 y una variaci n de frecuencia de 3 hz de los valores nominales que aparecen en la placa de identificaci n del generador A fin de evitar da os siempre tenga una carga adicional enchufada al generador en
86. es tapes 4 et 5 pour chague charge suppl mentaire Ne jamais ajouter de charges sup rieures la capacit du g n rateur Bien veiller a consid rer les charges de surtension comme d crit pr c demment ATTENTION Ne pas surcharger la capacit du g n rateur Le d passement de la capacit du wattage de l amp rage du g n rateur peut endommager le g n rateur et ou les appareils lectriques qui lui sont reli s Watts de fonc tionnement estim Watts d marrage estim Application Eguipo Urgence la maison de sec ours Radio r veil Lampes 4 qty x 75 W R frig rateur 700 2200 800 2350 300 a o Ventilateur de g n rateur d air chaud 1 2 ch Pompe de puits 1000 1000 1050 2100 1800 2000 Les wattages indiqu s sont approximatifs V rifier le wattage sur l outil ou l appareil Micro ondes Pompe de vidange 1 2 ch Cuisini re lectrique par l l ment Site de travail Perceuse lectrique 1 2 ch Pulv risateur sans air 1 3 ch Lampe de travail quartz halog ne 1000 Scie alternative 1600 1400 1800 Compresseur air 1 ch Scie circulaire 184 mm 7 1 4 po Raboteuse d gauchisseuse 152 mm 6 po 1800 2000 Scie onglet 254 mm 10 po Scie circulaire table scie circulaire tous azimuts 254 mm 10 po Page 9 Fran ais CARACT RISTIQUES FICHE TECHNIQUE MOTEUR Type de moteur 4 temps OHC transmission
87. esentes todos los art culos enumerados en la lista de empaquetado NOTA Esta herramienta es pesada y requiere al menos de dos personas para levantarla Para evitar una lesi n en la espalda lev ntela con sus piernas no con su espalda A ADVERTENCIA No utilice este producto si alguna pieza incluida en la lista de piezas sueltas ya esta ensamblada al producto cuando lo desempaqueta El fabricante no ensambla las piezas de esta lista en el producto stas deben ser instaladas por el usuario El uso de un producto que puede haber sido ensamblado de forma inadecuada podr a causar lesiones personales graves E Inspeccione cuidadosamente la unidad para asegurarse que no haya sufrido ninguna rotura o da o durante el transporte E No deseche el material de empaquetado hasta que haya inspeccionado cuidadosamente el producto y lo haya utilizado satisfactoriamente E Si hay piezas da adas o faltantes le suplicamos llamar al 1 800 242 4672 donde le brindaremos asistencia LISTA DE PIEZAS SUELTAS Voir la figure 3 Los siguientes accesorios vienen incluidos con el generador N m ref Descripci n Cant T 30 gt 0 ES rrr rereeer er errrerrr a 2 A 0 On 2 3 Pasadores de enganche 2 A Pies d Soporte srren anahi 2 5 Pernos 1 4 20 x 1 1 2 pulg ccccie iiien reses 2 Arandelas land sise 2 7 Arandelas de seguridad 2 8 Tuercas 1 4 20
88. esta secci n COBERTURA DE LA GARANT A DEL FABRICANTE Este sistema de control de emisi n evaporativa est garantizado por tres a os En caso de existir una pieza defectuosa relacionada con la emisi n evaporativa sta ser reparada o reemplazada por Homelite Consumer Products Inc RESPONSABILIDADES DEL PROPIETARIO EN RELACI N CON LA GARANT A HM Como propietario de una equipo peque o para uso fuera de carreteras usted es responsable de la realizaci n del mantenimiento necesario indicado en el manual del propietario Homelite Consumer Products Inc le recomienda guardar todos los recibos y facturas de mantenimiento de la equipo peque o para uso fuera de carreteras no obstante Homelite Consumer Products Inc no puede negar la cobertura de la garant a nicamente por la carencia de recibos Sin embargo como propietario de una equipo peque o para uso fuera de carreteras usted debe saber que Homelite Consumer Products Inc puede negarle la cobertura de la garant a si dicha equipo peque o para uso fuera de carreteras o una parte de la misma ha fallado debido a abuso descuido o mantenimiento indebido o modificaciones no autorizadas Usted es responsable de presentar su equipo peque o para uso fuera de carreteras a un establecimiento de servicio de Homelite Consumer Products Inc tan pronto como surja el problema Las reparaciones amparadas por la garant a deben realizarse en un plazo razonable menor de 30 d as
89. estreintes Utiliser un ventilateur ou ouvrir une fen tre ou les portes NE fournie PAS assez d air frais a respirer Utilisez SEULEMENT la g n ratrice l ext rieur et loin des fen tres ouvertes des portes ouvertes et des bouches d a rations Ces ouvertures peuvent tirer l air provenant du tuyau d chappement M me si vous utilisez une g n ratrice correctement des gaz CO peuvent toujours s infiltrer dans la maison TOUJOURS utiliser une alarme de monoxyde de carbone piles dans votre maison Si vous ressentez que vous commencez tre tourdi ou faible suite au fonctionnement de la g n ratrice allez prendre l air frais IMM DIATEMENT Consultez un m decin Vous pourriez avoir un empoisonnement au monoxyde de carbone A AVERTISSEMENT Lire et comprendre toutes les instructions Le non respect de toutes les instructions ci dessous peut entrainer une lectrocution un incendie et ou un empoisonnement au monoxyde de carbone pouvant causer des blessures graves voire mortelles A AVERTISSEMENT Le code lectrique am ricain National Electric Code requiert que le g n rateur soit mis a la terre par l interm diaire d une source de terre approuv e Avant d utiliser la borne de terre consulter un lectricien qualifi un inspecteur en lectricit ou un organisme local connaissant les codes et les r glements locaux applicables a l utilisation pr vue du g n rateur CONSERVER CES INSTRUCTIONS
90. filtro Sies necesario ponga en funcionamiento la unidad hasta vaciar el tanque o supervise el filtro antes de llenarlo Para reemplazar H Gire la v lvula de combustible hasta la posici n Apagado E Quite la tuber a del combustible de ambos lados del filtro apretando los extremos del sujetador de retenci n con pinzas H Deslice la tuber a de combustible mM Reemplazo del filtro de combustible H Vuelva a instalar las tuber as de combustible al nuevo filtro de combustible E Tiredelasl neas para asegurarse de que estan asegurados H Gire la v lvula de combustible hasta la posici n Encendido TRANSPORTE E Ponga el interruptor del motor en OFF O APAGADO E Ponga la v lvula de combustible en la posici n OFF APAGADO H Aseg rese de que est n fr os el motor y el escape de la unidad E Mantenga nivelada la unidad para evitar derramar el combustible E No deje caer la unidad no la golpee ni la coloque bajo objetos pesados P gina 15 Espa ol MANTENIMIENTO ALMACENAMIENTO Al preparar el generador para guardarlo deje que la unidad se enfrie por completo y luego siga los lineamientos sefialados abajo TIEMPO DE ALMACENAMIENTO ANTES DE GUARDARLO Menos de dos meses MH Vacie el tanque de combustible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones estatales y locales De dos meses a un Drene el combustible del carburador a o Vac e el tanque de combus
91. for gasoline Position the unit on level ground stop engine and allow to cool before refueling Loosen fuel cap slowly to release pressure and to keep fuel from escaping around the cap Tighten the fuel cap securely after refueling Wipe spilled fuel from the unit Never attempt to burn off spilled fuel under any circum stances Generators vibrate in normal use During and after the use of the generator inspect the generator as well as extension cords and power supply cords connected to it for damage resulting from vibration Have damaged items repaired or replaced as necessary Do not use plugs or cords that show signs of damage such as broken or cracked insulation or damaged blades For power outages permanently installed stationary gen erators are better suited for providing back up power to the home Even a properly connected portable generator can become overloaded This may result in overheating or stressing the generator components possibly leading to generator failure Use only authorized replacement parts and accessories and follow instructions in the Maintenance section of this manual Use of unauthorized parts or failure to follow maintenance instructions may create a risk of shock or injury Page 3 English IMPORTANT SAFETY INSTRUCTIONS H Maintain the unit per maintenance instructions in this Operator s Manual E Inspect the unit before each use for loose fasteners fuel leaks etc Replace damag
92. fraiche un mauvais carburant La prise c a ne fonctionne pas Disjoncteur d clench Enclencher le disjoncteur c a L appareil branch est d fectueux Essayer un autre article Le g n rateur met un cognement ou Un cognement ou un cliquettement Choisir une autre marque et s assurer un cliquettement sous une lourde charge est normal que l indice d octane est sup rieur ou Cependant s il a lieu sous une charge gal a 86 Si le probl me continue normale a un r gime moteur r gulier le contacter le centre de r parations agr probl me peut provenir de la marque le plus proche de carburant utilis e Si le probl me persiste apr s avoir essay les solutions ci dessus contacter le centre de r parations agr le plus proche pour obtenir de l aide Les sympt mes suivants peuvent indiquer des probl mes affectant le niveau d missions de l unit E D marrage difficile ou calage apr s le d marrage E Ralenti irr gulier H Rat s ou retours de flamme sous charge mM Post combustion retours de flamme E Fum e d chappement noire ou consommation de carburant lev e En cas de pr sence d un de ces sympt mes faire inspecter l unit et la faire r parer par le centre de r parations agr le plus proche Page 17 Fran ais GARANTIE GARANTIE LIMIT E COUVERTURE DE LA GARANTIE Homelite Consumer Products Inc l entreprise garantit l acheteur original au d tail que ce produit
93. genera tor and batteries m Do not connect to a building s electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician E Do not allow children or untrained individuals to use this unit m Never start or run the engine inside a closed or partially enclosed area Breathing exhaust fumes will kill you Keep all bystanders children and pets at least 10 feet away Wear sturdy and dry shoes or boots Do not operate while barefoot Do not operate generator when you are tired or under the influence of drugs alcohol or medication Keep all parts of your body away from any moving parts and all hot surfaces of the unit Do not touch bare wire or receptacles Do not use generator with electrical cords which are worn frayed bare or otherwise damaged Before storing allow the engine to cool and drain fuel from the unit Do not operate or store the generator in rain snow or wet weather Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generator Empty fuel tank close fuel valve and restrain the unit from moving before transporting in a vehicle Allow engine to cool for five minutes before refueling To reduce the risk of fire and burn injury handle fuel with care It is highly flammable Do not smoke while handling fuel Store fuel in a container approved
94. generador debe conectarse a tierra correctamente Siempre debe utilizarse la tuerca y el terminal de conexi n a tierra del bastidor para conectar el generador a una fuente apropiada de conexi n a tierra La conexi n a tierra debe realizarse con alambre calibre N 8 Conecte el terminal del alambre de conexi n a tierra entre la arandela y la tuerca y apriete firmemente la tuerca Conecte el otro extremo del alambre firmemente a una fuente apropiada de conexi n a tierra El C digo El ctrico Nacional especifica varias maneras pr cticas para establecer una buena fuente de conexi n a tierra Si se utiliza una barra de acero o de hierro ste debe ser de 15 9 mm 5 8 pulg de di metro y si se utiliza una barra no ferrosa sta debe ser de 13 mm 1 2 pulg de di metro como m nimo y estar listada como material adecuado para conexi n a tierra Hinque la barra o tubo hasta una profundidad de 2 44 m 8 pies Si se encuentra roca s lida a menos de 1 22 m 4 pies de profundidad entierre la barra o tubo en una zanja Todas las herramientas el ctricas y aparatos alimentados por este generador deben conectarse apropiadamente a tierra mediante el uso de un tercer alambre o tener un dise o con doble aislamiento Se recomienda 1 Usar dispositivos el ctricos con clavija de tres patillas conectada a tierra 2 Para asegurar la continuidad de la protecci n a tierra del generador al dispositivo utilice un cord n de extensi n con un
95. i n OFF APAGADO H Lleve el interruptor del motor a la posici n de APAGADO O Para apagar el motor en una situaci n de emergencia H Lleve el interruptor del motor a la posici n de APAGADO 0 P gina 13 Espa ol MANTENIMIENTO A ADVERTENCIA Al dar servicio a la unidad s lo utilice piezas de repuesto id nticas El empleo de piezas diferentes puede causar un peligro o da ar el producto A ADVERTENCIA Siempre p ngase protecci n ocular con la marca de cumplimiento de la norma ANSI Z87 1 La inobservancia de esta advertencia puede permitir que los objetos lanzados hacia los ojos puedan provocarle lesiones graves Solamente las piezas enumeradas en la lista de piezas pueden ser reparadas o cambiadas por el consumidor Todas las piezas restantes deben ser reemplazadas en un centro de servicio autorizado MANTENIMIENTO GENERAL Mantenga el generador en un entorno limpio y seco en el cual no est expuesto al polvo tierra humedad o vapores corrosivos No permita que las ranuras de aire de ventilaci n del generador se tapen de materia extra a como hojas etc No utilice una manguera de jard n para limpiar el generador El agua que entra al sistema de combustible u otras partes internas puede causar problemas que acortan la vida de servicio del generador Para limpiar la unidad E Conun cepillo de cerdas suaves y o una aspiradora afloje y elimine la tierra y la basura H Limpie las aberturas
96. iliser uniquement L EXT RIEUR et loin des fen tres des portes et des vents DANGER DANGER APELIGRO You WILL be KILLED or SERIOUSLY HURT Risk of fire Do not add fuel Generator is a potential source of electric shock Do not Exhaust contains poisonous carbon monoxide gas that can cause Failure to properly ground generator can result in Do not expose to if you do not follow the Operator s Manual while the product is operating expose to moisture rain or snow Do not operate with _ 2727 pad unconsciousness or DEATH Operate in well ventilated outdoor areas away electrocution especially if the generator is rain of use in instructions Reread wet hands or feet LL from open windows or doors equipped with a wheel kit damp locations Ne pas proc der de la mani re d crite ACT F4 4 i D c Le g n rateur est une source potentielle de chocs L chappement contient le gaz monoxyde de carbone toxique qui peut Une mauvaise mise la terre du g n rateur peut Ne pas exposer dans ce Manuel d utilisation entra nera l utilisation de l appareil e causer une lectrocution surtout si le g n rateur la plui est quip d un kit de roue ou l humidit La omisi n de conectar a tierra adecuadamente el No exponga a la generador puede resultar en electrocuci n especialmente lluvia ni use en si el generador est equipado con un kit de ruedas lugares himedos causer l inconscience ou la MORT Fonctionner dans les secteurs bien venti
97. io directivo de Subaru Robin ESTA GARANT A Y LA OBLIGACI N DE SUBARU ROBIN S EXPRESADA EN EL PRESENTE DOCUMENTO SUSTITUYEN CUALESQUIER OTRAS GARANT AS U OBLIGACIONES DE CUALQUIER INDOLE EXPRESAS O IMPLICITAS INCLUSO CUALESQUIER GARANT AS DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPOSITO PARTICULAR NO EXISTEN GARANT AS QUE SE EXTIENDAN SOBRE LO DESCRITO LITERALMENTE EN ESTE DOCUMENTO EN NINGUNA CIRCUNSTANCIA ROBIN AMERICA HABR DE SER RESPONSABLE POR NINGUN DANO CONSECUENTE O INCIDENTE P gina 19 Espa ol GARANT A LA SIGUIENTE DECLARACI N DE LA OFICINA DE RECURSOS ATMOSF RICOS DE CALIFORNIA CARB SE APLICA S LO A LOS MODELOS OBLIGADOS A CUMPLIR CON LOS REQUISITOS DE DICHO ORGANISMO DECLARACI N DE GARANT A LIMITADA DE HOMELITE CONSUMER PRODUCTS INC Y REGULACIONES FEDERALES Y DEL ESTADO DE CALIFORNIA EN RELACION CON LOS SISTEMAS DE CONTROL DE EMISIONES DE MOTORES NO VEHICULARES Y DE MOTORES PEQUENOS PARA USO FUERA DE CARRETERAS Su nuevo producto a gasolina de HOMELITE cumple con todas las normas de emisiones aplicables de la Direcci n de protecci n ambiental EPA de EE UU de Medioambiente de Canad Environment Canada y del Estado de California La porci n de emisiones evaporativas de esta cobertura como se describe a continuaci n es suministrada por Homelite Consumer Products Inc El fabricante del motor proporciona una cobertura de garant a en las emisiones por separado para componentes relacionados con
98. it Une utilisation de l quipement dans des conditions non s ches Choc lectrique et le non respect des m thodes sans danger peuvent entrainer un choc lectrique Durant le fonctionnement le g n rateur met du monoxyde de carbone un gaz toxique inodore et incolore Respirer le monoxyde de carbone peut entrainer des naus es des vanouissements voire la mort Vapeurs toxiques Le carburant et ses vapeurs sont extr mement inflammables et Incendie explosion explosifs Un incendie ou une explosion peut entrainer des br lures graves voire la mort Pour viter les risques de blessures ou de dommages viter tout Surface chaude contact avec les surfaces br lantes Pour r duire le risque de blessures graves viter de lever le g n rateur seul or Consulter un lectricien local pour d terminer les exigences de Mise a la terre uae mise la terre avant le fonctionnement Une mauvaise mise la terre du g n rateur peut causer une lectrocution surtout si le g n rateur est quip d un kit de roues Danger au levage lectrocution Page 5 Fran ais SYMBOLES Certains des symboles ci dessous peuvent tre utilis s sur le produit Veiller les tudier et apprendre leur signification Une interpr tation correcte de ces symboles permettra d utiliser le produit plus efficacement et de r duire les risques NOM SYMBOLE V D P A D SIGNATION EXPLICATION H
99. l If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO mM Never use a generator inside homes garages crawl spaces or other partly enclosed areas Deadly levels of carbon monoxide can build up in these areas Us ing a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or bat tery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You could have carbon monoxide poisoning A WARNING Read and understand all instructions Failure to follow all instructions listed below may result in electrocution fire and or carbon monoxide poisoning which will cause death or serious injury A WARNING National Electric Code requires generator to be grounded to an approved earth ground Before using the ground terminal consult a qualified electrician electrical inspec tor or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the
100. l s et ext rieurs loin d ouvre des fen tres ou des portes El escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento o MUERTE Opere en reas exteriores bien ventiladaslejos de puertas o ventanas abiertas ADANGER 4 DANGER E L utilisation d une g n ratrice l int rieur PEUT VOUS TUER ENQUELQUES MINUTES Using a generator indoors CAN KILL YOU IN MINUTES Les g n ratrices produisent du monoxyde de carbone un gaz mortel incolore et inodore Generator exhaust contains carbon monoxide This is a NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME SI les portes et poison you cannot see or smell les fen tres sont ouvertes Utiliser uniquement A L EXTERIEUR et loin des fen tres des portes et des vents PELIGRO Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno 1 que no puede verse ni olerse Only use OUTSIDE and NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las far away from windows ventanas abiertas j doors and vents S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos lectriques Ne pas exposer l humidit la pluie ou la gg neige Ne pas utiliser avec les mains ou les pieds mouill s EI generador es una fuente de descarga el ctrica No lo exponga a humedad la lluvia nin a la nieve No opere con mano
101. l escape contiene gas venenoso de mon xido de carbono que puede causar p rdida del conocimiento a la MUERTE Opere en reas exteriores bien ventiladas lejos de puertas o ventanas abiertas La omisi n de conectar a tierra adecuadamente el generador puede resultar en electrocuci n especialmente si el generador est a equipado con un kit de ruedas No exponga la unidad a la lluvia ni la use en lugares h medos Usar un generador en el interior PUEDE MARTARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo utilicelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos DANGER A DANGER PELIGRO You WILL be KILLED or SERIOUSLY HURT Risk of fire Do not add fuel il you do not follow the Operator s Manual while the product is operating instructions i Risque d incendie Ni Ne pas proc der de la mani re d crite Y eee DAN dans ce Manuel d utilisation entra nera EZ hee des BLESSURES GRAVES voire la MORT SE MATAR o LESIONAR GRAVEMENTE Generator is a potential source of electric shock Do not expose to moisture ra n or snow Do not operate with wet hands or feet Le g n rateur est une source potentielle de chocs neige Ne pas utiliser avec les mains ou les pieds mouill s El generador es una fuente de descarga el ctrica No lo
102. l generador est debidamente conectado a una tierra aprobada Comuniquese con un electrista para todo lo relacionado con los requistos de conexi n a tierra 940680021 03 Page 7 English ELECTRICAL EXTENSION CORD CABLE SIZE Refer to the table below to ensure the cable size of the extension cords you use are capable of carrying the required load Inadequate size cables can cause a voltage drop which can burn out the appliance and overheat the cord Current in Load in Watts Maximum Allowable Cord Length At120V At240V 8Wire 10Wire 12Wire 14 Wire 16 Wire 6 toot eo0r asf 2508 eo sot soot 2008 test teo som 2008 test toor aso iom toor soft eon toon ese eo 2400 4800 ist test 7ste 3 es soo 6000 isor tor pp so soo 7200 testo estn so 4800 o sor ELECTRIC MOTOR LOADS It is characteristic of common electric motors in normal operation to draw up to six times their running current while start ing This table may be used to estimate the watts required to start Code G electric motors however if an electric motor fails to start or reach running speea turn off the appliance or tool immediately to avoid equipment damage Always check the requirements of the tool or appliance being used compared to the rated output of the generator Watts Required to Start Motor Motor Size H P Repul
103. l lubricante de motor empleado es un factor de gran importancia en el rendimiento y vida de servicio del motor P gina 12 Espa ol FUNCIONAMIENTO Para uso general a todas temperaturas se recomienda el aceite SAE 10W 30 Siempre utilice lubricante para motor de cuatro tiempos que satisfaga o sobrepase los requisitos SJ de clasificaci n de servicio API NOTA El lubricante sin detergente o para motor de dos tiempos da a el motor por lo cual no debe usarse E Desenrosque la tapa de relleno de aceite varilla medidora de aceite y ret rela E Limpie la varilla de nivel y vuelva a asentarla en el agujero no la enrosque E Retire de nuevo la varilla medidora de lubricante y verifique el nivel de lubricante El nivel de lubricante siempre debe estar entre las reas cubierta con rayas entrecruzadas de la varilla medidora E Si est bajo el nivel abastezca de lubricante el motor hasta que el nivel del fluido alcance la parte superior de la varilla Vuelva a colocar la tapa de relleno de aceite varilla medidora de aceite y aseg rela VERIFICACI N Y ABASTECIMIENTO DE COMBUSTIBLE Vea la figura 9 E Retire la tapa de combustible E Llene el tanque de combustible hasta una altura de 2 5 cm 1 pulg abajo del cuello del tanque E Coloque de nuevo la tapa del tanque de combustible y aseg rela NOTA Siempre utilice gasolina sin plomo con un octanaje nominal inicial de 86 o mayor Nunca utilice gasolina vieja pas
104. l pour viter les interf rences sonores L utilisation du g n rateur dans des conditions mouill es peut entra ner l lectrocution Conserver l unit au sec Garder le g n rateur au moins 1 m 3 pieds de tout type de mat riau combustible Ne jamais utiliser le g n rateur pr s de mat riaux dangereux Ne pas utiliser le g n rateur pr s d une station de distribution d essence ou de gaz naturel Ne pas toucher le silencieux ou le cylindre durant ou imm diatement apr s l utilisation lls sont BRULANTS et peuvent provoquer des br lures Cette g n ratrice est quip e d un connecteur neutre libre Cela signifie que le conducteur neutre n est pas reli lectriquement au cadre de l unit Ne pas laisser le r servoir de carburant du g n rateur d border lors du remplissage Remplir 25 mm 1 po en dessous du goulot du r servoir de carburant pour permettre l expansion V rifier que l orifice de ventilation dans le bouchon du r servoir de carburant ne contient pas de d bris Ne pas boucher l vent Ne pas fumer lors du remplissage du g n rateur avec de l essence Fermer le moteur et le laisser refroidir compl tement avant l ajout de carburant ou la lubrification de la g n ratrice Ne pas retirer la jauge d huile ou le bouchon du r servoir de carburant lorsque le moteur tourne Bien tenir compte de tous les autocollants de s curit situ s sur le g n rateur Garderles enfants un minimum de
105. la r paration selon le besoin ne r duit pas la dur e de la couverture de garantie Une telle pi ce r par e ou remplac e dans le cadre de la garantie doit tre garantie pour une dur e non inf rieure a la p riode de garantie restante Toute pi ce de garantie qui est pr vue pour un remplacement dans le cadre de l entretien requis dans les instructions crites doit tre garantie pour la p riode indiqu e avant le premier remplacement pr vu de la pi ce Sila pi ce connait une d faillance avant le premier remplacement pr vu elle doit tre r par e ou remplac e par le fabricant offrant la garantie Une telle piece r par e ou remplac e dans le cadre de la garantie doit tre garantie pour une dur e non inf rieure a la p riode restante indiqu e avant le premier remplacement pr vu de la pi ce La r paration ou le remplacement de toute pi ce garantie dans le cadre de la pr sente garantie doivent tre effectu s sans frais pour le propri taire a un centre de r paration sous garantie Nonobstant les dispositions de la sous section 4 ci dessus les services et r parations dans le cadre de la garantie doivent tre effectu s aupres de centres de distributions poss dant une franchise pour l entretien de l quipement en question 6 Les travaux de diagnostic permettant de d terminer qu une pi ce sous garantie est d fectueuse doivent tre gratuits pour le propri taire tant qu ils ont t effectu aupr s
106. lace if necessary To purchase a replacement spark arrestor contact Homelite customer service at 1 800 242 4672 E Use a brush to remove carbon deposits from the spark arrestor screen as needed DRAINING FUEL TANK CARBURETOR See Figures 17 18 To help prevent gum deposits in the fuel system drain the fuel from the tank and carburetor before storing DRAINING THE FUEL TANK E Turn the engine switch OFF O E Turn the fuel valve to the OFF position E Remove the fuel line from the petcock by squeezing the ends of the retaining clip and sliding the fuel line off E Install one end of a drain line over the petcock and place the other end in a fuel container large enough to catch the fuel being drained from the tank E Turn the fuel valve to the ON position E When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on petcock DRAINING THE CARBURETOR H Turn the engine switch OFF O E Turn the fuel valve to the OFF position E Position a suitable container under the carburetor drain screw to catch fuel loosen the screw E Allow fuel to drain completely into container E Retighten drain screw NOTE Consult hazardous waste management guidelines in your area for the proper way to dispose of used fuel REPLACING FUEL FILTER See Figure 19 Occasionally the fuel filter may become clogged and need replacing To purchase a replacement fuel filter contact Homelite customer service at
107. lar en las instrucciones por escrito debe ser garantizada por el tiempo de garant a definido en la subsecci n b 2 Una declaraci n en dichas instrucciones por escrito para el efecto de reparar o reemplazar seg n sea necesario no reducir el tiempo de cobertura de la garant a Cualquier pieza reparada o reemplazada en virtud de la garant a debe ser garantizada por un periodo no inferior al tiempo restante de la garant a Cualquier pieza garantizada que est en el calendario para reemplazo como lo requiere el mantenimiento en las instrucciones por escrito debe ser garantizada por el tiempo previo al primer punto de reemplazo programado para esa pieza Si la pieza falla previa al primer cambio programado la pieza debe ser reparada o reemplazada por el fabricante que expide la garant a Cualquier pieza reparada o reemplazada en virtud de la garant a debe ser garantizada por un periodo no inferior al tiempo al primer punto de reemplazo programado para la pieza La reparaci n o reemplazo de cualquier pieza garantizada en virtud de las restricciones de la garant a de este art culo debe ser realizada sin cargo al propietario en la estaci n de garant a No obstante de las restricciones de la subsecci n 4 anteriormente citada los servicios o reparaciones de garant a debe ser proporcionados en los centros de distribuci n que son franquiciados para dar servicio a los motores o equipos sujetos 6 No debe haber cargo para el pr
108. le g n rateur dans un environnement propre et sec sans exposition a la poussi re la salet l humidit ou des vapeurs corrosives Ne pas laisser les vents de refroidissement du g n rateur s obstruer avec des feuilles de la neige etc Ne pas utiliser un tuyau de jardinage pour nettoyer le g n rateur De l eau p n trant dans le circuit de carburant ou d autres pi ces internes de l unit peut causer des probl mes r duisant la dur e de vie du g n rateur Pour nettoyer l unit H Utiliser une brosse poils doux et ou un aspirateur pour d tacher et retirer la salet et les d bris H Nettoyer les vents pression basse ne d passant pas 25 psi E Essuyer les surfaces ext rieures du g n rateur avec un chiffon humide INSPECTION NETTOYAGE DU FILTRE AIR Voir la figure 13 Pour assurer un fonctionnement correct et une longue vie utile garder les filtre air propres E Desserrerles vis qui se trouvent sur le dessus et le dessous du couvercle du filtre air Retirer le couvercle et mettre de c t H Retirer les l ment du filtre air E Si les l ment du filtre air est sale les nettoyer avec de l eau savonneux chaude Rincer et laisser s cher H Appliquer une l g re couche d huile moteur sur les l ments puis l essorer E Replacer le l ment dans le filtre air HM Replacer le couvercle du filtre air et resserrer les vis pour le fixer NOTE Ne pas faire tourner le
109. lesiones serias evite intentar levantar el Peligro al levantar generador usted solo Consulte a un electricista de la localidad para determinar los Conexi n a tierra Ap 2 a requisitos de conexi n a tierra antes de utilizar la unidad El incumplimiento de conectar correctamente a tierra el generador Electrocuci n puede resultar en electrocuci n especialmente si el generador est equipado con un conjunto de disco P gina 5 Espa ol S MBOLOS Es posible gue se empleen en este producto algunos de los siguientes s mbolos Le suplicamos estudiarlos y aprender su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N ETIQUETAS DE SEGURIDAD La siguiente informaci n puede encontrarse en el generador Para su propia seguridad le sugerimos estudiar y entender todas la etiqu etas antes de poner marcha el generador Si se desprende de la unidad cualquiera de las etiquetas o se vuelven ilegibles comun guese con alg n centro de servicio autorizado para obtener un reemplazo SE MATAR o LESIONAR GRAVEMENTE si no sigue las instrucciones del Manual del operador Riesgo de incendio No agregue combustible cuando el producto est functionando El generador es una fuente potencial de descarga el ctrica No lo exponga a humedad la lluvia nin a la nieve No opere con manos o pies h medos E
110. lete Failure to comply could result in possible serious personal injury TOOLS NEEDED See Figure 4 The following tools not included or drawn to scale are needed for assembly m 7 16 in 1 2 and 9 16 in socket wrench m 7 16 in 1 2 and 9 16 in combination wrench NOTE Do not put fuel or lubricant in the generator before installing the feet frame support and wheels INSTALLING THE FRAME SUPPORTS See Figure 5 E Locate the following items 2 support feet 2 nuts 1 4 20 2 flat washers 2 lock washers 2 bolts 1 4 20 x 1 1 2 in E Position the generator and the support foot so the holes in the support foot align with the holes in the generator frame E Insert bolt flat washer lock washer and nut Tighten nut securely E Repeat with remaining support INSTALLING THE WHEELS See Figure 6 Wheels are provided to assist in moving the generator to the desired location and should be installed on the side opposite the handle E Locate the following items 2 axles 2 hitch pins 2 washers 2 wheels E Raise the end of the generator where the handle is located high enough to gain access to the frame bottom securely position props underneath to support E Slide the axle through the hole in the center of the wheel Page 11 English ASSEMBLY E Slide a washer onto the axle then slide the axle into the wheel mounting hole as shown E Insert hitch pin to secure NOTE The hitch pin should be pushed
111. livered transportation prepaid to such Distributor or Service Center for inspection and repair All repairs qualifying under this Limited Warranty must be performed by Subaru Robin or one of its authorized Distributors or Service Centers WARRANTY PERIODS Subaru Four Cycle EX and EH Series 4 3 hp or greater Gasoline Engines Limited 3 year Warranty Subaru Four Cycle EH Series LP NG Engines Limited 3 year Warranty Subaru Mini Four Cycle EH025 EHO35 EHO35V Gasoline Engines Limited 2 year Warranty Subaru SP170 SP210 Gasoline Engines Private Residental Limited 3 year Warranty Subaru SP170 SP210 Gasoline Engines Commercial Limited 1 year Warranty Subaru Rammer Series Gasoline Engines Limited 2 year Warranty Subaru EA190V EA175V Gasoline Engines Private Residental Limited 3 year Warranty Subaru EA190V EA175V Gasoline Engines Commercial Limited 1 year Warranty The repair or replacement of any part or parts under this Limited Warranty shall not extend the term of the engine warranty beyond the original term as set forth above LIMITATIONS AND EXCLUSIONS This Limited Warranty shall not apply to 1 Bent or broken crankshaft or resultant damage caused by vibration related to a bent or broken crankshaft Also damage caused by loose engine mounting bolts or improper or imbalanced accessories or blades mounted to the crankshaft 2 Repairs required because of prolonged storage including damage caused by old or contaminated fuel in the
112. ll always be operated at alti tudes above 5 000 feet Contact your nearest authorized service center for more information and to have these modifications performed Operating voltage and frequency requirement of all electronic equipment should be checked prior to plug ging them into this generator Damage may result if the equipment is not designed to operate within a 10 voltage variation and 3 hz frequency variation from the generator name plate ratings To avoid damage al ways have an additional load plugged into the generator if solid state equipment Such as a television set is used A power line conditioner is recommended for some solid state applications For outdoor use only Save these instructions Refer to them frequently and use them to instruct others who may use this product If you loan someone this product loan them these instructions also Page 4 English SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING Indicates an imminently hazardous situation which if not avoided will result DANGER in death or serious injury g Indicates a potentially hazardous situation which if not avoided could result WARNING in death or serious injury q Indicates a potentially hazardous situation which if not avoided may result in CAUTION minor or moderate injury CAUTION Without Safety Alert Symbol Indicates a
113. n 75 vatios 0 3475 vatios 2200 vatios poten potencia en cia inicial m xima marcha total Potencia continua total en vatios en marcha 3475 Potencia inicial adicional m xima en vatios 2200 Potencia total de salida requerida del generador 5675 ADMINISTRACI N DE LA POTENCIA A fin de prolongar la vida til del generador y los dispositivos acoplados es importante tener cuidado al agregar cargas el ctricas al generador NO debe haber equipo alguno conectado a los tomacorrientes del generador antes de poner en marcha el motor respectivo La manera correcta y segura de administrar la potencia del generador consiste en agregar las cargas de manera secuencial de la manera siguiente 1 Sin equipos conectados al generador ponga en marcha el motor de la manera que se describe posteriormente en este manual 2 Enchufe y active la primera carga preferiblemente la m xima carga que tenga 3 Deje que se estabilice la salida del generador el motor marcha uniformemente y el dispositivo acoplado funciona correctamente 4 Enchufe y active la siguiente carga 5 Nuevamente deje que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional Nunca a ada m s cargas que las que permita la capacidad del generador Tenga especial cuidado al considerar las cargas de sobrecorriente en la capacidad del generador seg n se describi anteriormente PRECAUCI N No exceda la capacidad del generador Si excede la
114. nes del Manual L utilisation d une g n ratrice l int rieur PEUT VOUS TUER ENQUELQUES MINUTES Les g n ratrices produisent du monoxyde de carbone un gaz mortel incolore et inodore les fen tres sont ouvertes Utiliser uniquement L EXTERIEUR et loin des fen tres des portes et des vents PELIGRO Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo utilicelo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos NEVER use inside a home Only use OUTSIDE and or garage EVEN IF doors far away from windows an windows are open doors and vents Page 6 English SYMBOLS FUEL WARNING DANGER DANGER PELIGRO No smoking when filling with gasoline Do not overfill Full level Risk of Fire Check for any fuel overflow or leaking Stop the engine before refueling is 1 in below the top of the fuel neck Stop the engine for five N eoo peren minutes before refueling to avoid the heat from the muffler Prenon oa Incanto E RIUS alge ese o Nga de combustible Apaga RS igniting fuel vapors ENGINE LUBRICANT WARNING You must add lubricant before first operating the generator The oil reservoir capacity is 1 1 at Always check the lubricant Ajouter de lub
115. o de la garant a del motor en exceso del plazo original estipulado anteriormente LIMITACIONES Y EXCLUSIONES Esta Garant a Limitada no habra de aplicarse a 1 Cig e ales doblados o rotos ni a da os consecuentes causados por la vibraci n relacionada con un cig e al doblado o roto Adem s el da o causado por pernos sueltos de montaje del motor o por accesorios err neos o desbalanceados ni por aspas instaladas en el cig e al 2 Las reparaciones necesarias debido al almacenamiento prolongado incluso los da os causados por combustible deteriorado por el tiempo o contaminado en el tanque de combustible tuber as de combustible o el carburador v lvulas pegajosas ni la corrosi n u xido de las piezas dle motor 3 Reparaciones necesarias debido al calentamiento excesivo Muy a menudo causado por sobrecargas o por volantes ventiladores pasajes de entrada de aire aletas de enfriamiento o cubiertas de enfriamiento obstruidos da ados O faltantes 4 El desgaste relacionado con la suciedad o mugre causado por el mantenimiento insuficiente del filtro de aire que a menudo resulta en desgastes prematuros en el pist n en los anillos del pist n en los cilindros en las v lvulas en las gu as de las v lvulas en el carburador o en otros componentes internos 5 Piezas rotas o abolladas como consecuencia de bajos niveles de aceite aceite contaminado o grado err neo de aceite 6 Afinados de motor y servicio normal de mantenimient
116. o entre los que se incluyen el ajuste de v lvulas reemplazo normal de componentes de servicio combustible y aceite lubricante etc 7 Cualquier motor que haya estado sujeto a negligencia uso indebido accidente aplicaci n err nea o a exceso de velocidad 8 Cualquier motor instalado reparado o modificado por persona alguna y de tal manera que a juicio de Subaru Robin se afecte adversamente el rendimiento o fiabilidad de dicho motor 9 Cualquier motor que se haya instalado o reparado con piezas o componentes que no hayan sido fabricados o autorizados por Subaru Robin y que a juicio de Subaru Robin afecten el desempe o o fiabilidad de dicho motor 10 Situaciones en las que el uso normal ha agotado la vida til de un componente o de un motor El cliente es responsable de todos los gastos de transporte en conexi n con cualquier trabajo bajo garant a Subaru Robin se reserva el derecho de cambiar modificar o mejorar cualquier motor o sus componentes sin incurrir en la obligaci n alguna para modificar o reemplazar cambiar motor o componentes vendidos anteriormente sin incurrir en obligaci n alguna de modificar o reemplazar ning n motor o componentes vendidos previamente sin incluir dicho cambio modificaci n o mejora Ninguna persona est autorizada para otorgar ninguna otra garant a ni para asumir obligaciones adicionales en nombre y representaci n de Subaru Robin a menos que ello se haga por escrito y est firmado por un funcionar
117. obin dans le cadre de cette garantie limit e sera limit e la r paration et au remplacement l option de Subaru Robin de toute pi ce s av rant apr s inspection l avis de Subaru Robin tre d fectueuse en mat riau ou fabrication Une condition aux obligations de Subaru Robin dans le cadre de cette garantie limit e est que Subaru Robin recoive rapidement directement ou par l interm diaire d un de ses distributeurs ou centres der parations agr s entretenir le moteur particulier impliqu un avis de r clamation sous garantie et que le moteur ou les pi ces d clar es comme tant d fectueuses soient rapidement livr es frais de port pr pay s audit Distributeur ou Centre de r parations pour inspection et r paration Toute r paration qualifiant dans le cadre de cette garantie limit e doit tre effectu e par Subaru Robin ou un de ses distributeurs ou centres de r parations agr s P RIODES DE GARANTIE Moteurs essence quatre temps de Subaru s ries EX et EH de 4 3 HP ou plus Garantie limit e 3 ans Moteurs quatre temps propane liquide ou gaz naturel de Subaru s rie EH Garantie limit e 3 ans Mini moteurs essence quatre temps EH025 EH035 et EH035V de Subaru Garantie limit e 2 ans Moteurs essence Subaru SP170 SP210 Priv R sidentiel Garantie limit e 3 ans Moteurs essence Subaru SP170 SP210 Commerciaux Garantie limit e 1 an Moteurs essence Subaru de la s rie Rammer Gar
118. ol System Warranty included with this product Of course this product also includes a warranty that is not limited to emissions related components as described elsewhere in this operator s manual YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board and Homelite Consumer Products Inc are pleased to explain the evaporative emission control systems warranty on your 2011 model year small off road equipment In California new equipment that uses small off road engines must be designed built and equipped to meet the State s stringent anti smog standards Homelite Consumer Products Inc must warrant the evaporative emission control system on your small off road equipment for the period listed below provided there has been no abuse neglect or improper maintenance of your equipment Your evaporative emission control system may include parts such as carburetors fuel tanks fuel lines fuel caps valves canisters filters vapor hoses clamps connectors and other associated components For engines less than or equal to 80 cc only the fuel tank is subject to the evaporative emission control warranty requirements of this section MANUFACTURER S WARRANTY COVERAGE This evaporative emission control system is warranted for three years If any evaporative emission related part on your equipment is defective the part will be repaired or replaced by Homelite Consumer Products Inc OWNER S WARRANTY RESPONSIBILITIES
119. ol s II est recommand 1 d utiliser des appareils lectriques avec prises de terre trois fiches 2 d utiliser un cordon prolongateur avec prise 3 p les et une fiche 3 broches aux extr mit s oppos es pour assurer la continuit de la protection de mise la terre du g n rateur l appareil Consulter et respecter tous les r glements nationaux et locaux applicables concernant les sp cifications de mise la terre Consulter un lectricien qualifi ou le personnel de service si les instructions de mise la terre ne sont pas bien comprises ou en cas de doute au sujet de la mise la terre Page 2 Fran ais INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT A DANGER Monoxyde de Carbone Utiliser une g n ratrice a l int rieur d un batiment CAUSERA LA MORT EN QUELQUES MINUTES Le tuyau d chappement de la g n ratrice contient un niveau lev de monoxyde de carbone CO lequel s av re tre un gaz poison inodore et invisible Si vous pouvez sentir les gaz du tuyau d chappement de la g n ratrice vous respirez du CO Mais m me si vous ne pouvez pas sentir les gaz provenant du tuyau d chappement vous pourriez tre en train de respirer du CO u Ne jamais utiliser une g n ratrice l int rieur d une maison des garages des petits espaces ou autres aires restreintes partiellement ferm es Des niveaux mortels de monoxyde de carbone peuvent s accumuler dans ces aires r
120. opietario por la mano de obra de diag n stico que determina el que una pieza garantizada est defectuosa siempre y cuando dicho diagn stico sea realizado en una estaci n de garant a 7 Durante todo el tiempo de la garant a del sistema de control de emisi n evaporativa fijada en la subsecci n b 2 el fabricante que expide la garant a debe mantener un suministro suficiente de piezas garantizadas para cumplir con la demanda esperada para dichas piezas 8 Las piezas de repuesto aprobadas por el fabricantes deben ser utilizadas en la realizaci n de cualquier mantenimiento o reparaciones de garant a y deben ser proporcionadas sin costo al propietario Tal uso no reducir las obligaciones de la garant a del fabricante que expide la garant a 9 El uso de piezas modificadas o a adidas ser motivo para no permitir un reclamo de la garant hecho de acuerdo con este art culo El fabricante que expide la garant a no ser responsable en virtud de este art culo a garantizar defectos de piezas garantizadas debido al uso de una pieza modificada o a adida El fabricante que expide esta garant a proporcionar todos los docu mentos que describen los procedimientos o pol ticas de garant a dentro de cinco d as laborales de la solicitud por la Junta de Recursos Atmos f ricos Air Resources Board LISTA DE PIEZAS DE GARANT A DE EMISI N 1 Tanque de combustible Tapa del tanque Mangueras de combustible Recept culo de carb n
121. or exhaust contains carbon monoxide This is a ADANGER oison you cannot see or smell NEVER use inside a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents L utilisation d une g n ratrice a l int rieur PEUT VOUS TUER ENQUELQUES MINUTES Les g n ratrices produisent du monoxyde de carbone un gaz mortel incolore et inodore NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME SI les portes et les fen tres sont ouvertes Utiliser uniquement A L EXTERIEUR et loin des fen tres des portes et des vents Usar un generador en el interior PUEDE MATARLO EN POCOS MINUTOS Los gases de escape del generador contienen mon xido de carbono Es un veneno que no puede verse ni olerse NUNCA lo use dentro de su hogar o del garaje INCLUSO con las puertas y las ventanas abiertas S lo util celo AL AIRE LIBRE y lejos de ventanas puertas y respiraderos DANGER A PELIGRO P gina 6 Espa ol S MBOLOS ADVERTENCIA DE COMBUSTIBLE G A DANGER A DANGER A PELIGRO No fume al abastecer el combustible No llene de m s El nivel de Risk of Fire Check for any fuel overflow or leaking Stop the engine before refueling lleno es 25 mm 1 pulg debajo del cuello del tanque de combustible Risque d incendie V rifier l absence de d bordement ou de fuite de carburant Pare la marcha del motor cinco minutos antes d
122. or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You could have carbon monoxide poisoning A DANGER Failure to properly ground generator can result in elec trocution especially if the generator is equipped with a wheel kit National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements A WARNING Do not allow familiarity with this product to make you careless Remember that a careless fraction of a second is sufficient to inflict serious injury A WARNING Do not use any attachments or accessories not recommended by the manufacturer of this product The use of attachments or accessories not recommended can result in serious personal injury APPLICATIONS This generator is designed to supply electrical power for operating compatible electrical lighting appliances tools and motor loads BEFORE OPERATING THE UNIT E Only use OUTSIDE and far away from windows doors and vents E NEVER use inside a home or garage EVEN IF doors and windows are open E Always position the generator on a flat firm surface CAUTION Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure CHECKING ADDING LUBRICANT See Figure 8 Engine lubricant has a major influence on engine perfor mance and service life For general all temperature use
123. osion normal wear and tear or repairs by other than the Company or its authorized service representative E n addition this warranty does not cover Tune ups Spark Plugs Carburetor Carburetor Adjustments Ignition Filters Oil Change e Wear items Recoil Starter Rope Engine Brushes Cotter Pins Wheels Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instruc tions and recommendations of the Company as set forth in the Product s operator s manual or if the Product is used as rental equipment The Company will not pay for repairs or adjustments to the Product or for any costs or labor performed without the Company s prior authorization SAVE YOUR SALES SLIP Proof of purchase in the form of your dated sales receipt cash register slip etc will be required before the Company and or its authorized service representatives can perform warranty service on the Product EXCLUSIONS AND LIMITATIONS THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE APPLICABLE TO THIS PRODUCT SHALL BE LIMITED IN DURATION TO THE DURATION OF THIS LIMITED WARRANTY THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY THE COMPANY SHALL NOT BE LIABILE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW A LIMITATION ON THE DURATION OF IMPLIED
124. ou des r parations effectu es par quiconque autre que le personnel de l entreprise ou de son repr sentant autoris du service la client le E En outre la pr sente garantie exclut Les r glages bougies carburateur r glages du carburateur allumage filtres vidange d huile Les articles soumis l usure cordon du d marreur rappel charbons du moteur goupilles fendues roues La garantie est consid r e comme nulle si le produit n est pas install entretenu et utilis conform ment aux instructions et aux recommandations de l entreprise qui sont d crites dans le manuel d utilisation du produit La garantie s annule galement si le produit est utilis des fins de location L entreprise n assumera en aucun cas les frais li s la r paration ou l ajustement du produit ou les co ts associ s des t ches pour lesquelles elle n a pas donn son consentement CONSERVER LES FACTURES Une preuve d achat sous la forme d un re u de vente ou de caisse dat est requise pour que l entreprise ou ses repr sentants autoris s du service la client le puissent proc der l entretien sous garantie du produit EXCLUSIONS ET LIMITES CETTE GARANTIE LIMIT E REMPLACE TOUTES LES AUTRES GARANTIES EXPRESSES LA DUR E DE TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE DE QUALIT DE CONVENANCE DES FINS PARTICULI RES OU DE TOUT AUTRE COUVERTURE APPLICABLE CE PRODUIT NE PEUT EXC DER LA DUR E DE LA PR SENTE
125. ouun autre r cipient approuv et en secouant doucement pour m langer E Replacer et serrer le bouchon Mettre le moteur en marche et le faire tourner pendant au moins 5 minutes pour que le stabilisateur p n tre dans tout le circuit de carburant CARBURANTS OXYG N S NE PAS UTILISER LE CARBURANT E85 LE NON RESPECT DE CETTE DIRECTIVE ENTRAINE L ANNULATION DE LA GARANTIE NOTE Les dommages au circuit de carburant etles probl mes de performance r sultant de l utilisation de carburant oxyg n contenant des pourcentages de composants oxyg n s sup rieurs ceux indiqu s pr c demment ne sont pas couverts par la garantie Ethanol L essence contenant jusqu 10 d thanol par volume g n ralement d sign e E10 est acceptable L essence d sign e E85 ne l est pas ATTENTION Sur une surface a niveau avec le moteur sur arr t v rifier le niveau d huile avant chaque utilisation du g n rateur MISE EN MARCHE DU MOTEUR Voir les figures 10 a 12 NOTE Si l emplacement de g n rateur n est pas a niveau l unit peut ne pas d marrer ou peut s arr ter durant le fonctionnement mM D brancher toutes les charges du g n rateur E Ouvrir le robinet de carburant m Ecarter droit le levier d tranglement la position START D MARRAGE NOTE Si le moteur est chaud ou que la temp rature est sup rieure 10 C 50 F carter gauche le levier d tranglement sur la position RUN
126. par chaine Al sage x Course 75 mm x 65 mm Syst me de refroidissement Air forc Taux de compression iiccciciicccicaaneeee oses 8 3 1 Syst me de d marrage rappel Syst me d allumage Transistoris Bougie NGK BR 6HS or Champion RL86C Volume de lubrifiant moteur 1 01 1 1 qt Volume de carburant 22 7 6 gal G N RATEUR Tension nominale 120 V 240 V Amp rage nominal 41 6 A 20 8 A Watts de fonctionnement nominale 5000 W Watts de d marrage nominale 6250 W Fr quence nominale 60 Hz DIMENSIONS EA 673 1 mm 26 5 po T RE ee te I Le 508 mm 20 po HAUTEUR aasien 584 2 mm 23 po POIDS SR D SR ie 72 6 kg 160 Ib Watts de fonctionnement nominale r solu par la norme de PGMA G200 BIEN CONNA TRE LE G N RATEUR Voir la figure 2 L utilisation s re de ce produit exige une compr hension des renseignements figurant sur le produit et contenus dans le manuel d utilisation ainsi qu une bonne connaissance du projet entrepris Avant d utiliser ce produit se familiariser avec toutes ses caract ristiques et r gles de s curit DISJONCTEUR C A Le disjoncteur est fourni pour prot ger le g n rateur contre les surcharges lectriques Soulevez le levier de disjoncteur pour le r enclencher FILTRE AIR Le filtre
127. parcialmente cerrada La inhalaci n de las emanaciones del escape puede ser mortal Mantenga a todos los circunstantes ni os y animales por lo menos a 3 m 10 pies de distancia Use botas o zapatos robustos y secos No utilice la unidad estando descalzo No utilice este generador cuando se encuentre fatigado enfermo o bajo los efectos de drogas alcohol o medicamentos Mantenga todas las partes del cuerpo alejadas de toda pieza m vil y superficie caliente de la unidad No toque cables ni recept culos desprovistos de aislamiento No utilice el generador con cordones de corriente gastados deshilachados pelados o da ados de cualquier forma Antes de guardar la unidad deje que se enfr e el motor y retire el combustible de la unidad No utilice or guarde el generador en la lluvia nieve o tiempo h medo Guarde el generador en un lugar bien ventilado y con el tanque de combustible vac o El combustible no se debe guardar cerca del generador Antes de transportar la unidad en un veh culo vac e el tanque de combustible cierre la v lvula del combustible e inmovilice aqu lla Deje enfriar el motor durante cinco minutos antes dereabastecerlo de gasolina Para reducir el riesgo de incendio o de lesiones por quemadura maneje con cuidado el combustible Es sumamente inflamable No fume mientras est mezclando el combustible o reabasteciendo el tanque Almacene el combustible en un recipiente aprobado para ga
128. r lesiones menores o leves R AI Sin el s mbolo de alerta de seguridad Indica una situaci n que puede PRECAUCION producir da os materiales Es posible que se empleen en este producto algunos de los siguientes s mbolos Le suplicamos estudiarlos y aprender su significado Una correcta interpretaci n de estos s mbolos le permitir utilizar mejor y de manera m s segura el producto S MBOLO NOMBRE DENOMINACI N EXPLICACI N Alerta de seguridad Indica un peligro posible de lesiones personales Para reducir el riesgo de lesiones el usuario debe leer y comprender Lea el manual del operador el manual del operador antes de usar este producto Alerta de condiciones No exponga la unidad a la lluvia ni la use en lugares h medos h medas Si no se usa la unidad en condiciones secas y no se observan Descarga el ctrica pr cticas seguras de trabajo puede producirse una descarga el ctrica Con el funcionamiento del generador se emite mon xido de Emanaciones t xicas carbono un gas t xico incoloro e inodoro Si se inhala mon xido de carbono puede causarse n usea desmayo o la muerte El combustible y los vapores del mismo son extremadamente Fuego Explosi n inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Para reducir el riesgo de lesiones corporales o da os materiales SUperiicie callemte evite tocar toda superficie caliente Para reducir el riesgo de
129. r and gasoline can be mixed prior to filling the tank by using a gas can or other approved fuel container and shaking gently to combine E Replace and secure the fuel tank cap E Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system OXYGENATED FUELS DO NOT USE E85 FUEL IT WILL VOID YOUR WAR RANTY NOTE Fuel system damage or performance problems re sulting from the use of an oxygenated fuel containing more than the percentages of oxygenates stated below are not covered under warranty Ethanol Gasoline containing up to 10 ethanol by volume commonly referred to as E10 is acceptable E85 is not CAUTION On a level surface with the engine off check the lubricant level before each use of the generator STARTING THE ENGINE See Figures 10 12 NOTE If location of generator is not level the unit may not start or may shut down during operation E Unplug all loads from the generator E Turn the fuel valve to the ON position Move the choke lever right to the START position NOTE If engine is warm or the temperature is above 50 F move the choke lever left to the RUN position H Put the engine switch in the ON 1 position E Pull the recoil starting grip until the engine runs a maxi mum of 6 times NOTE Do not allow the grip to snap back after starting return it gently to its original place E Allow the engine to run for 15 seconds then move the choke
130. r modified part 10 The manufacturer issuing the warranty shall provide any documents that describe the warranty procedures or policies within five working days of request by the Air Resources Board EMISSION WARRANTY PARTS LIST 1 Fuel Tank 2 Fuel Cap Fuel Hoses Carbon Canister Vapor Hoses Hose Clamps Hose Connectors 8 Vapor Fuel Check Valve Written instructions for the maintenance and use of the evaporative emis sions control system by the owner shall be furnished with each new small off road equipment Page 20 English TABLE DES MATI RES E Introduction nd 2 E Instructions importantes concernant la s curit oooocconoocccccconaoacnncnnanonnnncnnnnnnoncnnnno nro n conan nn nn n cnn rn rn e ez t EEEREN EEEE 3 4 H R gles de s curit particuli res cnn 4 MB SYMbol S Pr rt Rea e 5 7 M Caract ristiques lectriques ccccccsscccceseeneeeeeeseneeeeecseaeeeeeecaaeeeeesseaeeeeesscuseeeeeceaaeeeececeaeeeeeseseaeeeeesseteeesesseeseeeeeeaas 7 9 O E A UE E O seen esenneeseneenennesenneenes 10 H Assemblage ssiru eraan ouest AOC V Ada EAER DENNERT EEEN 11 12 E O e rai A E TE E E E E D D 12 13 E a EEA E E E E AA E AEAEE E R E 14 16 E D pannage isise ar eieaa a NA enc asda nde cee eden vida AEEA EEE ere den nE e EE Eaa 17 O 18 20 E Commande de pi ces r paration Page arri re INTRODUCTION Ce produit offre de nombreuses fonctions destin es rendre son utilisation plus plaisante et plus satisf
131. rant a Limitada que Subaru Robin directamente o a trav s de uno de sus Concesionarios o Centros de Servicio autorizados para llevar a cabo el mantenimiento del motor particular involucrado reciba notificaci n oportuna de cualquier reclamaci n en virtud de la garant a y que el motor o las piezas presuntamente defectuosas se entreguen oportunamente con flete prepagado a dicho Concesionario o Centro de servicio para su inspecci n y reparaci n Todas las reparaciones que califiquen en virtud de esta Garant a Limitada deber realizarlas Subaru Robin uno de sus Concesionarios autorizados o sus Centros de Servicio PLAZOS DE GARANT A Motores de gasolina Subaru de cuatro ciclos series EX y EH 4 3 hp o m s Limitada de 3 a os garant a Motores de PL GN Subaru de cuatro ciclos serie EH Limitada de 3 a os garant a Mini motores de gasolina Subaru de cuatro ciclos EHO25 EHO35 EHO35V Limitada de 2 a os garant a Motores de gasolina Subaru SP170 SP210 Privado Residencial Limitada de 3 a os garant a Motores de gasolina Subaru SP170 SP210 Comercial Limitada de 1 a o garant a Motores de gasolina Subaru serie Rammer Limitada de 2 a os garant a Motores de gasolina Subaru EA190V EA175V Privado Residencial Limitada de 3 a os garant a Motores de gasolina Subaru EA190V EA175V Comercial Limitada de 1 a o garant a La reparaci n o reemplazo de cualquiera de las piezas amparadas por esta Garant a Limitada no habr de prorrogar el plaz
132. re le plus lev au wattage nominal total de l tape 2 Page 8 Fran ais CARACT RISTIQUES LECTRIQUES Exemple Watts de Watts de Outil ou appareil fonctionnement surtension continu d marrage Climatiseur de fen tre 10 000 BTU 1600 R frig rateur 2200 Pompe de puits 2000 1 2 ch T l vision de 27 0 pouces clairage 75 W 0 3475 Wattage 2200 Wattage de fonctionnement de surtension total maximum Wattage continu fonctionnement total 3475 Plus wattage de surtension suppl mentaire maximum 2200 gal la sortie totale du g n rateur requise 5675 GESTION DE L NERGIE Pour prolonger la dur e de vie du g n rateur et des appareils reli s il est important d effectuer l ajout de charges lectriques suppl mentaires au g n rateur avec soin Rien ne doit tre connect aux sorties du g n rateur avant le d marrage du moteur Une gestion correcte et en toute s curit de l nergie du g n rateur consiste ajouter des charges en s quence 1 Sans appareil connect au g n rateur mettre le moteur en marche de la fa on d crite dans ce manuel 2 Brancher et mettre en marche la premi re charge de pr f rence la plus importante 3 Laisser la sortie du g n rateur se stabiliser le moteur tourne r guli rement et l appareil reli fonctionne correctement 4 Brancher et mettre la charge suivante en marche 5 Une fois de plus laisser le g n rateur se stabiliser 6 R p ter l
133. recept culo de tres orificios en un extremo y una clavija de tres patillas en el otro Revise y cumpla con todas las reglas federales estatales y locales relevantes en relaci n con las especificaciones de conexi n a tierra Consulte a un electricista calificado o t cnico de servicio si no ha comprendido completamente las instrucciones de conexi n a tierra o si no est seguro si el generador est conectado a tierra correctamente P gina 2 Espa ol INSTRUCCIONES DE SEGURIDAD IMPORTANTES A PELIGRO Mon xido de carbono Usar un generador en el interior LO MATAR EN POCOS MINUTOS Los gases de escape del generador contienen niveles altos de mon xido de carbono CO un gas venenoso que no puede verse ni olerse Si puede oler los gases de escape del generador est respirando CO Pero incluso si no puede oler los gases de escape es posible que est respirando CO Mm Nunca use un generador dentro de su hogar garaje s tano ni dem s espacios parcialmente encerrados En dichos espacios pueden acumularse niveles mortales de mon xido de carbono Usar un ventilador o abrir puertas y ventanas NO proporciona suficiente aire fresco S LO utilice el generador al aire libre y lejos de ventanas puertas y respiraderos abiertos Estas aberturas pueden atraer los gases de escape del generador Incluso si utiliza el generador correctamente el CO puede ingresar en su hogar SIEMPRE utilice una alarma de CO de pilas o con pilas
134. representantes de servicio autorizados H Adem s esta garant a no cubre Afinaci n Buj as carburador ajustes del carburador encendido filtros cambio de aceite Desgaste de piezas Cuerda del arrancador retr ctil escobillas del motor pasadores de chaveta ruedas La garant a queda anulada si el cliente no instala mantiene o utiliza el producto respetando las instrucciones y las recomendaciones de la Compa a seg n se expresa en el manual del operador del Producto o si el Producto se utiliza como equipo de alquiler La Compa a no se har cargo de las reparaciones o los ajustes al Producto o de cualquier tarea o gasto que no sea autorizado previamente por esta Compa a GUARDE SU COMPROBANTE DE COMPRA Antes de que la Compa a o sus representantes de servicio autorizados puedan efectuar el servicio correspondiente cubierto por la garant a del Producto se solicitar como comprobante de compra una factura de compra con fecha EXCLUSIONES Y LIMITACIONES ESTA GARANT A LIMITADA PREVALECE SOBRE CUALQUIER OTRA GARANT A EXPRESA CUALQUIER GARANT A IMPL CITA DE COMERCIABILIDAD IDONEIDAD PARA UN FIN ESPEC FICO U OTRA QUE BRINDE COBERTURA PARA ESTE PRODUCTO ESTAR LIMITADA EN DURACI N AL PLAZO DE ESTA GARANT A LIMITADA EL SERVICIO DE GARANT A DESCRITO ANTERIORMENTE ES EL NICO RECURSO BAJO ESTA GARANT A LA COMPA A NO SER RESPONSABLE DE CUALQUIER DA O ESPECIAL INDIRECTO O CONSECUENTE ALGUNOS ESTADOS NO
135. rifiant jusqu au rep re de remplissage pour demarrer TE ne d marrera pas ou s arr tera si le niveau de lubrifiant H H est Das level before each operation The lubricant level should always Afiada lubricante hasta la marca de ileno para arrancar El motor no register between the hatched areas on the dipstick LIRE arrancar o se apagar si el nivel de lubricante est demasiado bajo GROUNDING WARNING National Electric Code requires generator to be grounded to an approved earth ground A WARNING A WARNING A AVERTISSEMENT A ADVERTENCIA HOT SURFACE Product does not include ground rod or copper wire National Electric Code requires generator to be properly grounded to an approved earth ground Call an electrician for local grounding requirements Le produit ne comprend pas de piquet de terre ou de fil en cuivre Le code electrique americain National Electric Code requiert un g n rateur pour A AVERTISSEMENT SURFACE TRES CHAUDE HOT SURFACE WARNING ADVERTENCIA Do not touch the muffler or aluminum cylinder of the engine They are very HOT and will cause SUPERFICIE severe burns Don t put any flammable or combustible materials in the direct path of the exhaust CALIENTE une bonne mise la terre approuv e Appeler un lectricien pour conna tre les exigences locales de mise la terre El producto no incluye el alambre de cobre ni la barra de conexi n a tierra Los Reglamentos Nacionales de Electricidad exigen que e
136. ro est conectado por v as el ctricas al marco de la m quina No permita que el dep sito de gas del generador se desborde durante la carga Cargue a 25 4 mm 1 pulg por debajo de la parte superior del tanque de gasolina para permitir la expansi n del combustible No cubra la tapa del tanque de combustible cuando el motor est en funcionamiento Al cubrir la tapa del tanque de combustible durante el funcionamiento se puede producir una falla en el motor o un da o a la herramienta No fume mientras abastece de gasolina el generador Apague el motor y d jelo enfriar por completo antes de agregar gasolina o lubricante al generador No retire la varilla de nivel de aceite ni la tapa del tanque del combustible mientras est funcionando el motor Preste atenci n en particular a todas las etiquetas de seguridad adheridas al generador En todo momento mantenga a los ni os a una distancia m nima de 3 m 10 pies del generador La unidad funciona mejor a una temperatura entre 5 y 40 C 23 y 104 F con una humedad relativa de 9 o menos Es necesario modificar el generador si va a utilizarse siempre auna altitud superior a 1524 metros 5000 pies Comun quese con el centro de servicio autorizado de su preferencia si necesita m s informaci n y para que realicen tales modificaciones El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador P
137. roduct that may have been improperly assembled could result in serious personal injury E Inspect the unit carefully to make sure no damage oc curred during shipping E Do not discard the packing material until you have carefully inspected and satisfactorily operated the product E If any parts are damaged or missing please call 1 800 242 4672 for assistance LOOSE PARTS LIST See Figure 3 The following items are included with the generator Key No Description Qty 1 Wheels 2 2 O Zea na Ea 2 3 MiteN PINS siistia ainan baz E ia anade anaiai 2 4 Support Feet 2 5 Bolts 1 4 20 x 1 1 2 in 2 6 Flat Washers 2 7 Lock Washers 2 8 Nuts 0d 0 sa0040269 9900 cnan 006 2 A TE 2 10 Bottle of Engine Lubricant 1 Operator s Manual not SHOWN 1 A WARNING If any parts are damaged or missing do not operate this product until the parts are replaced Use of this product with damaged or missing parts could result in serious personal injury A WARNING Do not attempt to modify this product or create acces sories not recommended for use with this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious per sonal injury A WARNING Do not attempt to operate the generator until assembly is comp
138. rotecci n de los elementos pruebe el GFCI del recept culo cada vez antes de usar la unidad CAPACIDAD DEL GENERADOR Cerci rese que el generador pueda suministrar suficientes vatios de potencia continua en marcha y de sobrecorriente al arrancar para los equipos que desee alimentar al mismo tiempo Siga estos pasos sencillos 1 Seleccione los equipos que desea alimentar al mismo tiempo 2 Sume la potencia continua en marcha en vatios de estos equipos Esta es la cantidad de potencia que el generador debe producir para mantener en marcha los equipos Observe la tabla de referencia de potencia en vatios a la derecha 3 Calcule cu nta potencia inicial al arranque en vatios necesitar La potencia inicial en vatios es la breve variaci n r pida de potencia necesaria para poner en marcha los aparatos o herramientas accionados con motor el ctrico como las sierras circulares o los refrigeradores Debido a que no todos los motores arrancan al mismo tiempo se puede calcular la potencia inicial total en vatios sumando s lo los equipos con el mayor valor de potencia inicial adicional a la potencia nominal del paso 2 P gina 8 Espa ol ASPECTOS EL CTRICOS Ejemplo Potencia inicial arranque en Potencia continua en marcha en Herramienta o aparato vatios vatios Acondicionador de aire de ventana 1800 10000 BTU Refrigerador 2200 Bomba de pozo de 1 3 HP 2000 Televisor de 27 pulg 0 Iluminaci
139. rt from around base of spark plug E Remove spark plug using wrench not included H Inspect spark plug for damage and clean with a wire brush before reinstalling If insulator is cracked or chipped spark plug should be replaced NOTE If replacing use the following recommended spark plugs or equivalent NGK BR 6HS or Champion RL86C E Measure plug gap The correct gap is 0 028 0 031 in 0 7 0 8 mm To widen gap if necessary carefully bend the ground top electrode To lessen gap gently tap ground electrode on a hard surface m Seat spark plug in position thread in by hand to prevent cross threading mM Tighten with wrench to compress washer If spark plug is new use 1 2 turn to compress washer appropriate amount If reusing old spark plug use 1 8 to 1 4 turn for proper washer compression NOTE An improperly tightened spark plug will become very hot and could damage the engine Page 14 English MAINTENANCE CLEANING THE EXHAUST PORT AND MUFFLER Depending on the type of fuel used the type and amount of lubricant used and or your operating conditions the exhaust port and muffler may become blocked with carbon deposits If you notice a power loss with your gas powered products you may need to remove these deposits to restore perfor mance We highly recommend that only qualified service technicians perform this service SPARK ARRESTOR See Figure 16 E Inspect the spark arrestor for breaks or holes Rep
140. s have the unit inspected and repaired by the nearest authorized service center Page 17 English WARRANTY LIMITED WARRANTY WARRANTY COVERAGE Homelite Consumer Products Inc the Company warrants to the original retail purchaser that this Homelite Product is free from defects in material and workmanship and agrees to repair or replace at the Company s discretion any defective Product free of charge within these time periods from the date of purchase E Three years if the Product is used solely for personal family or household use E One year if the Product is used for business or commercial use This warranty applies only to Products sold within the United States of America the District of Columbia Canada Mexico the Commonwealth of Puerto Rico the Virgin Islands or Guam This warranty is not transferable and does not cover damage resulting from defects other than in material or workman ship or damage caused by unreasonable use including the failure to provide reasonable and necessary maintenance Other items not covered under this warranty include E Transportation charges for sending the product to the Company or its authorized service representative for warranty service or for shipping repaired or replacement products back to the customer these charges must be borne by the original retail purchaser E Damages caused by abuse accident misuse neglect alteration modification the effects of corrosion er
141. s agujeros en el armaz n del generador E Inserte el perno la arandela plana la arandela de segu ridad y la tuerca Ajuste bien la tuerca E Repita estos pasos con el otro soporte INSTALACI N DE LAS RUEDAS Vea la figura 6 Las ruedas se proporcionan para ayudar a trasladar el generador hasta la ubicaci n deseada y deben instalarse en el lado opuesto al mango H Localice los siguientes art culos 2 ejes 2 pasadores de enganche 2 arandelas 2 ruedas H Eleve el extremo del generador donde est ubicado el mango hasta una altura suficiente que permita el acceso a la parte inferior del bastidor coloque firmemente cu as debajo para apoyarlo H Deslice pase el eje a trav s del agujero situado en el centro de la rueda E Desliceuna arandela por el eje y luego deslice el eje dentro del agujero de montaje de la rueda como se muestra P gina 11 Espa ol ARMADO E Inserte el pasador de enganche para asegurar NOTA Debe introducirse el pasador de enganche en el eje hasta que el centro de aqu l descanse en la parte superior de ste E Repita el proceso con la segunda rueda AJUSTE DEL MANGO Vea la figura 7 Sujete el mango y lev ntelo hacia atr s hasta que se fije en su lugar Aseg rese de que el mango est fijo en su lugar antes de intentar mover el generador Para plegar el mango a fin de almacenar la unidad mantenga presionado el pasador de liberaci n mientras empuja el mango hacia abajo A P
142. s o pies h medos des BLESSURES GRAVES voire la MORT SE MATAR o LESIONAR GRAVEMENTE si no sigue las instrucciones del Manual 01 del operador Riesgo del incendio No agregue combustible cuando el producto est functionando NEVER use inside a home or garage EVEN IF doors and windows are open Ne Page 6 Fran ais SYMBOLES AVERTISSEMENT CONCERNANT LE CARBURANT G A DANGER A DANGER A PELIGRO Ne pas fumer lors du plein Ne pas trop remplir Le plein est Risk of Fire Check for any fuel overflow or leaking Stop the engine before refueling obtenu 25 mm 1 po en dessous du haut du goulot de A ve L absence de d bordement ou de fuite de carburant remplissage Arr ter le moteur pendant cinq minutes avant de Riesgo de incendio Revise si hay alg n derrame o fuga de combustible Apague el motor antes de poner combustible 940974007 04 faire le plein pour viter que la chaleur du silencieux n allume les vapeurs de carburant AVERTISSEMENT CONCERNANTLELUBRIFIANT MOTEUR k apt yogi A a o Ajouter de lubrifiant jusqu au rep re de remplissage pour d marrer Ajouter de le lubrifiant avant l utilisation initiale du g n rateur Le moteur ne d marrera pas ou s arr tera si le niveau de lubrifiant La contenance du r servoir est de 1 0 1 1 quart Toujours A ada lubricante hasta la marca de ileno para arrancar El motor no CETO arrancar o se apagar si el nivel de lubricante est
143. s product Please study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better and safer SYMBOL NAME DESIGNATION EXPLANATION Ca om one S SAFETY LABELS E Exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH Operate in well ventilated outdoor areas away from open windows or doors The information below can be found on the generator For your safety please study and understand all of the labels before starting the generator If any of the labels come off the unit or become hard to read contact an authorized service center for replacement You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual instructions E Risk of Fire Do not add fuel while the product is operat ing E Generator is a potential source of electric shock Do not expose to moisture rain or snow Do not operate with wet hands or feet E Failure to properly ground generator can result in elec trocution especially if the generator is equipped with a wheel kit mM Do not expose to rain or use in damp locations H Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell m NEVER use inside a home or garage EVEN IF doors and windows are open m Only use OUTSIDE and far away from windows doors and vents des BLESSURES GRAVES SE MATARA o LESIONAR si
144. sion Induction Split Phase 1 8 6 eso 1200 1 6 CAUTION person who is using an appliance with faulty insulation and Operating voltage and frequency requirement of all at the same time is in contact with an electrical ground such electronic equipment should be checked prior to plugging as a Plumbing fixture wet floor or earth them into this generator Damage may result if the GFCI receptacles do not protect against short circuits over equipment is not designed to operate within a 10 loads or shocks voltage variation and 3 hz frequency variation fromthe The GFCI receptacles can be tested with the TEST and generator name plate ratings To avoid damage always RESET buttons have an additional load plugged into the generator if solid state equipment such as a television set is used A power line conditioner is recommended for some solid state applications To test E Depress the TEST button This should cause the Reset button to pop out E To restore power depress the RESET button GROUND FAULT CIRCUIT INTERRUPTER Perform this test monthly to ensure proper operation of the See Figure 1 GFCI If the generator is stored outdoors unprotected from The 20 amp 120volt receptacles on the generator are protect the weather test the GFCI receptacle before each use ed by a Ground Fault Circuit Interrupter GFCI which guards against the hazards of ground fault currents An example of ground fault current is
145. solina Coloque la unidad sobre el piso nivelado apague el motor y deje que se enfr e antes de reabastecerlo de combustible Afloje la tapa del tanque de combustible para aliviar la presi n y para evitar que se escape combustible por la tapa Despu s de reabastecer de combustible la unidad ponga la tapa y apri tela firmemente Limpietodo el combustible que se haya derramado dela unidad Nunca intente en ninguna circunstancia eliminar el combustible derramado quem ndolo Los generadores vibran durante el uso normal Durante y despu s del uso del generador inspeccione el generador as como los cordones de extensi n y los cordones de corriente conectados a ste para ver si tienen da os causados por la vibraci n Deben repararse o reemplazarse los art culos da ados seg n sea necesario No use enchufes ni cordones que muestren se ales de da o como roturas o agrietamientos en el aislamiento o da o en las espigas Los generadores fijos instalados de manera permanente son la mejor alternativa para abastecer de electricidad al hogar durante los cortes de energ a Incluso los generadores port tiles que est n conectados correctamente pueden sobrecargarse De esta manera los componentes del generador pueden recalentarse o exigirse demasiado lo que podr a producir una falla en el generador Use nicamente repuestos y accesorios autorizados y siga las instrucciones descritas en la secci n de Mantenimiento de este m
146. t Ne pas remiser le carburant proximit de la g n ratrice Pour le transport dans un v hicule le r servoir doit tre vide le robinet de carburant ferm et la machine bien arrim e Laisser le moteur refroidir pendant 5 minutes avant de faire le plein Manipuler le carburant avec pr caution pour viter les risques d incendies et de br lures Le carburant est extr mement inflammable Ne pas fumer pendant la manipulation du carburant Conserver le carburant dans un bidon ou jerrican approuv pour l essence Poser la machine sur un sol plat arr ter le moteur et le laisser refroidir avant de faire le plein Desserrer le bouchon du r servoir lentement pour rel cher la pression et viter que le carburant ne s chappe Une fois le r servoir plein remettre le bouchon en place et le serrer fermement Essuyer tout le carburant ventuellement r pandu N essayer en aucun cas de br ler le carburant r pandu Une vibration est normale pendant l utilisation de la g n ratrice Pendant et apr s l utilisation de la g n ratrice inspectez celle ci tout comme les c bles d extension et les c bles branch s la bo te d alimentation afin de d tecter tout bris potentiel du mat riel Faites r parer tout dommage imm diatement ou remplacer les pi ces endommag es au besoin Ne pas utiliser de fiches ou des c bles qui sont endommag s tels qu ils aient des signes de fissures ou si la couche isolante est craqu
147. t correct est de 0 7 0 8 mm 0 028 0 031 po Pour augmenter l cartement si n cessaire courber avec pr caution l lectrode de terre sup rieure Pour r duire l cartement taper doucement l lectrode de terre sur une surface dure E Installer la bougie la visser la main pour viter de foirer le filetage E Serrer avec la cl pour comprimer la rondelle Si la bougie est neuve utiliser 1 2 tour pour comprimer la rondelle Si elle est us e utiliser 1 8 1 4 de tour pour comprimer la rondelle NOTE Une bougie mal serr e devient tr s chaude et peut endommager le moteur Page 14 Fran ais ENTRETIEN NETTOYAGE DE L ORIFICE D CHAPPEMENT ET DU SILENCIEUX Selon le type de carburant utilis le type et la quantit de lubrifiant utilis e et ou les conditions d utilisation l orifice d chappement et le silencieux peuvent tre obstru s par de la calamine Si l appareil fonctionnant avec de l essence semble avoir perdu de la puissance cette calamine doit tre limin e pour restaurer le fonctionnement normal II est vivement recommand de confier ce travail un technicien qualifi PARE ETINCELLES Voir la figure 16 E Inspecter le pare tincelles pour des fissures ou des trous Le remplacer au besoin Pour se procurer un pare tincelles de remplacement communiquer avec le service la client le de Homelite au 1 800 242 4672 H Au besoin uiliser une brosse pour enlever les d p ts
148. thout incurring any obligation to modify or replace any engine or parts previously sold without such modification alternation or improvement No person is authorized to give any other warranty or to assume any additional obligation on Subaru Robin s behalf unless made in writing and signed by an officer of Subaru Robin THIS WARRANTY AND SUBARU ROBIN S OBLIGATION HERE UNDER ARE IN LIEU OF ANY OTHER WARRANTIES OR OB LIGATIONS OF ANY KIND EXPRESSED OR IMPLIED INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE OF ROBIN AMERICA SHALL IN NO EVENT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES Page 19 English WARRANTY THE FOLLOWING CALIFORNIA AIR RESOURCES BOARD CARB STATEMENT ONLY APPLIES TO MODEL NUMBERS REQUIRED TO MEET THE CARB REQUIREMENTS HOMELITE CONSUMER PRODUCTS INC LIMITED WARRANTY STATEMENT FOR FEDERAL AND CALIFORNIA EMISSION CONTROL SYSTEMS NON ROAD AND SMALL OFF ROAD ENGINES Your new HOMELITE brand gasoline powered product complies with all applicable U S EPA Environment Canada and State of California emis sions regulations The evaporative emissions portion of this coverage as described below is provided by Homelite Consumer Products Inc Separate emissions warranty coverage for other emissions related components is provided by the engine manufacturer as stated in a separate Emission Contr
149. tible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones estatales y locales Un a o o m s Drene el combustible del carburador Retire la buj a Vac e el tanque de combustible y col quelo en un recipiente apropiado seg n lo establecido por las disposiciones estatales y locales Ponga una cucharada sopera de aceite para motor en el cilindro de la buj a Gire el motor lentamente con la cuerda de tiro para distribuir el aceite Instale de nuevo la buj a Cambie el lubricante del motor Al sacar la unidad despu s de haberla tenido guardada M Reabastezca de gasolina fresca la unidad PROGRAMA DE MANTENIMIENTO Al cabo del Cada 3 meses o Cada 6 meses o Cada a o o luego es pate Sue 2 20 50 horas de func 100 horas de de 300 horas f ncionamiento ionamiento funcionamiento de funcionamiento Revisar el lubricante del motor Comprobar ajustar la velocidad de ralent Comprobar ajustar el huelgo de v lvula Limpiar el dep sito y el filtro de combustible Comprobar el tubo de combustible Reemplazo del filtro de combustible Estas tareas deben ser efectuadas s lo por el centro de servicio autorizado NOTA La frecuencia de mantenimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento de acuerdo con los intervalos all recomendados P gin
150. tos pertinentes al llamar o al presentarse personalmente Para obtener informaci n sobre el establecimiento de servicio autorizado m s cercano a usted le suplicamos llamar al 1 800 242 4672 o visitar nuestro sitio en la red mundial en la direcci n www homelite com PIEZAS DE REPUESTO El n mero de modelo de este producto se encuentra en una placa o etiqueta pegada a la caja del motor Le recomendamos anotar el n mero de serie en el espacio suministrado abajo N MERO DE MODELO N MERO DE SERIE HOMELITE CONSUMER PRODUCTS INC 1428 Pearman Dairy Road Anderson SC 29625 1 800 242 4672 e www homelite com
151. ueden ocurrir da os si el equipo no est dise ado para operar dentro de una variaci n de voltaje de 10 y una variaci n de frecuencia de 3 hz de los valores nominales que aparecen en la placa de identificaci n del generador A fin de evitar da os siempre tenga una carga adicional enchufada al generador en caso de usarse equipos de estado s lido tales como un aparato de televisi n Tambi n podr a resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones por ejemplo con una computadora Tambi n podria resultar necesario un condicionador de la l nea el ctrica para algunas aplicaciones de equipo de estado s lido Para el uso en el exterior solamente Guarde estas instrucciones Cons ltelas con frecuencia y empl elas para instruir a otras personas que puedan utilizar esta producto Si presta a alguien esta producto facil tele tambi n las instrucciones P gina 4 Espa ol S MBOLOS Las siguientes palabras de sefializaci n y sus significados tienen el objeto de explicar los niveles de riesgo relacionados con este producto S MBOLO SE AL SIGNIFICADO PELIGRO Indica una situaci n peligrosa inminente la cual si no se evita causar lesiones graves o mortales E Indica una situaci n peligrosa posible la cual si no se evita podr a causar ADVERTENCIA lesiones graves o mortales PRECAUCI N Indica una situaci n peligrosa posible la cual si no se evita podr a causa
152. un interrupteur de transfert lequel pourra allumer tous les conducteurs autres que celui du circuit lectrique principal Le cadre de la g n ratrice doit tre mis la terre par l interm diaire d une source de terre approuv e Si cette tape n est pas faite la g n ratrice ne sera pas isol e du circuit lectrique et cela pourrait entra ner des blessures graves voire m me la mort chez un lectricien travaillant pour l usine Ne pas utiliser cette g n ratrice pour alimenter les appareils d urgence m dicale ou le mat riel de survie L chappement contient du monoxyde de carbone un gaz toxique incolore et inodore L inhalation des fum es d chappement peut causer la perte de conscience et le d c s Sila machine tourne dans un endroit clos ou partiellement clos l air peut contenir une quantit dangereuse de monoxyde de carbone Pour viter l accumulation de fum es d chappement toujours assurer une ventilation ad quate Toujours utiliser un d tecteur de monoxyde de carbone fonctionnant sur piles lors de l utilisation du g n rateur En cas de sensation de naus e d tourdissement ou de faiblesse lors de l utilisation du g n rateur l arr ter et aller imm diatement l air frais Consulter un docteur Il peut s agir d un empoisonnement au monoxyde de carbone Placer le g n rateur sur une surface stable et plate Utiliser dans un endroit bien ventil et bien clair l cart des zones de travai
153. utilisation de pi ces et accessoires non recommand s peut entrainer des bles sures graves APPLICATIONS C g n rateur est con u pour fournir une alimentation lectrique pour le fonctionnement d clairages d appareils d outils et de charges de moteur compatibles AVANT D UTILISER L UNIT H Utiliser uniquement L EXT RIEUR et loin des fen tres des portes et des vents m NE JAMAIS utiliser l int rieur d une maison ou d un garage MEME SI les portes et les fen tres sont ouvertes mM Toujours poser la g n ratrice sur une surface stable et plate ATTENTION Une tentative de d marrage du moteur avant le remplissage en lubrifiant correct entraine une panne de l quipement Page 12 Fran ais UTILISATION V RIFICATION AJOUT DE LUBRIFIANT Voir la figure 8 Le lubrifiant moteur a une influence majeure sur la performance du moteur et la dur e de service De mani re g n rale et pour toutes temp ratures de l huile SAE 10W 30 est recommand e Toujours utiliser une huile moteur 4 temps conforme ou sup rieure aux exigences de service SJ API NOTE Des lubrifiants moteur 2 temps non d tergentes endommageront le moteur et ne doivent pas tre utilis es E D visser le capuchon d huile la jauge et les retirer E Essuyer la jauge et l ins rer de nouveau dans le trou sans visser H Retirer une nouvelle fois la jauge et v rifier le niveau de lubrifiant Le niveau de lubrifiant
154. z Fr guence cycles par seconde hrs Heures Dur e Gallon Volume a AUTOCOLLANTS DE S CURIT Les informations ci dessous se trouvent sur le g n rateur Pour des raisons de s curit tudier et comprendre tous les autocollants avant de mettre le g n rateur en marche Si un autocollant se d tache ou devient illisible contacter le centre de r parations agr pour obtenir un autocollant de rechange H Ne pas proc der de la mani re d crite dans ce manuel d utilisation entrainera des BLESSURES GRAVES voire la MORT E Risque d incendie Ne pas ajouter de carburant pendant L chappement contient le gaz monoxyde de carbone toxique qui peut causer l inconscience ou la MORT les secteurs bien ventil s et ext rieurs loin d ouvre des fen t ou des portes Une mauvaise mise la terre du g n rateur peut causer une lectrocution surtout si le g n rateur est quip d un kit de roue Ne pas exposer la pluie ou l humidit L utilisation d une g n ratrice l int rieur PEUT VOUS TUER EN QUELQUES MINUTES Les g n ratrices produisent du monoxyde de carbone un gaz mortel l utilisation de l appareil incolore et inodore m Le g n rateur est une source potentielle de chocs lec M NE JAMAIS utiliser l int rieur d une maison ou d un triques Ne pas exposer l humidit la pluie ou la neige garage MEME SI les portes et les fen tres sont ouvertes Ne pas utiliavec les mains ou les pieds mouill s H Ut
Download Pdf Manuals
Related Search
Related Contents
Linn FM/AM/DAB TUNER Stereo System User Manual Denon AH-D510 Copyright © All rights reserved.
Failed to retrieve file