Home

Harman Stove Company Conquest Gas Stove Stove User Manual

image

Contents

1. pesn aq eys i91injoejnuew aui Aq p d dns se UY UOISI AUOI y euedoud pue seb ein eu asn 104 L6IN LE e VO9O NVO CON EE CVSO 2002 88 122 ISNV O SI Joye ui asn JO OSIY ejqnsnquuoo UN Dane asin sed N SJOYI SN JO JON PIOS esn JO JON aqel SIU JOAOD JO jou IHM 121 1s nbuo5 jPPOW d sn 5 9 RU9A y HOOUIEM 4 sec jueA 129 pelsr 1 1 89 09100 2 1 10 09100 3 1 00 09102 4 1 00 09105 5 1 10 73102 6 3 43 09100 7 1 10 09108 8 3 40 09102 9 3 44 00539 10 3 44 08294 11 3 43 09110 12 2 00 73137 13 2 00 73138 14 3 40 09107 15 3 40 09108 16 3 40 09109 17 3 40 09105 18 1 10 73126 19 2 00 73127 20 2 00 73141 21 3 31 00521 22 2 00 73155 23 3 44 73133 MAINTENANCE Body weldment LP valve assembly Optional blower Optional window grid Pedestal weldment Gold door frame Door weldment Door glass Glass gasket 7 unit Flue gaskets Gold grill Top glass clip Bottom glass clip Rear brick panel Left brick panel Right brick panel Burner tube Burner plate weldment Burner clamp Air guide Relief door springs Relief door Relief door gasket 24 1 10 73130 25 1 10 73129 26 2 00 73147 27 2
2. PILOT to OFF unless it 15 pushed in slightly Do not force it FLAME HEIGHT ADJUSTMENT The flame height adjuster can be accessed by opening the right side panel Turn the adjuster clock wise to increase flame height and counterclockwise to decrease See above left Adjusting the flames too high will cause them to have black tips and cause sooting Sooting can cause the glass to get dirty Check flame height after five to ten minutes and re adjust if necessary Pilot Flames If pilot flames are less than shown at left use pilot adjuster shown below to increase flames Pilot Adjuster Warning The unit and adjuster may be hot Wear gloves and arm protection if making adjustments while in operation RATINGS Input Rating Btu hr 0 4500 ft 0 1375 m Min Input Rating Btu hr 0 4500 ft 0 1375 m Orifices DMS 0 4500 ft 0 1375 m Manifold Pressure in w c kPa Min Manifold Pressure in w c kPa Min Inlet Pressure in w c kPa Max Output Btu hr 0 4500 ft 0 1375 m Blower Off NATURAL 29000 14900 37 3 8 95 1 1 27 5 0 1 25 21375 SPECIFICATIONS 7 PROPANE 29000 14100 53 11 0 2 75 2 8 7 11 5 2 87 21854 2 in 8 in 3 in 16 in 16 in 7 AMP SPECIFICATIONS MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Unit to corner walls Unit to side wall Electrical Rating 120 Volts 60 Hz gt Unit to back wall Unit to alcove ceiling M
3. Switch OQ ON OFF Switch Speed Control Power Cord Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 23 2202 252 Auedwoyg anols Aq lt ZH 09 021 ul 9L uidep ul 9L uao HUN ULE O Hun Ul 8 EM apis 0 HUN Sjem 1 U102 O HUN NOILONYLSNOO S3ONVWHV3 IO NANININ SI IHL HIIHM 1314 AHL 531715 a i1naowW 131545 YANYNG JHL NO 713971 V HO G EL 0 14 0087 0 1u mg xep edy U UIN edy ul ensseJg ui edY ui ainssald PIOJIUeN GLE L 0 4 0OGP 0 SIWNA G EL 0 4 008 0 1 Bugey 1ndu 9161 0 009 0 2 79812 9261 28 9 1 0 9 2 8 2 2611 G 0 0 LL 967 8 5 LE 00 006r 0006c 0006c ANVdOdd SONLIVH oujne e ejgnsnquuoo un p Jossed nod eesi nn yop 3ue2uqeJ 9 Jed IUUNOJ UOISI AUOI aun euedoud Je ze bane uonesi nn enj ajeuiaje auj Jajeau SIU
4. WARNING Venting terminals must not be re cessed into a wall or siding In addition the following must be observed A The clearance above grade or a veranda porch deck or balcony must be a minimum of 12 30 cm B The clearance to a window or door that may be opened must be a minimum of 12 30 C A 12 30 cm clearance to a permanently closed window is recommended to prevent con densation on the window D The vertical clearance to a ventilated soffit located above the terminal within a horizontal dis tance of 2 feet 60 cm from the center line of the terminal must be a minimum of 18 46 cm E The clearance to an unventilated soffit must be a minimum of 12 30 cm F Theclearance to an outside corner is 11 from center of pipe G The clearance to an inside corner is 12 30 cm H A vent must not be installed within 3 feet 90 cm above a meter regulator assembly when measured from the horizontal center line of the regu lator INSTALLATION 12 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 8 m J The clearance to a non mechanical air sup ply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 12 inches 30 K The clearance to a mechanical air supply inlet must be a minimum of 6 feet 1 8 m L The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 fee
5. installation amp Operating Manual The Harman Conquest Gas Stove WA Ce manuelest disponible en Francais sur demande C Ercan US R6 SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE BODILY INJ URY OR EVEN DEATH i Warnock Hersey I FOR USE IN THE U S AND CANADA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLE D A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILDING DEPARTMENT FIRE DEPARTMENT FIRE PREVENTION BUREAU ETC TO DETERMINE THE NEED FORA PERMIT CETTE GUIDE D UTILISATION EST DISPONIBLE EN FRANCAIS CHEZ VOTRE CONCESSIONNAIRE DE HARMANS DOVE COMPANY SAVE THESE INSTRUCTIONS This appliance must be installed in accordance with local codes if any if not follow the current edition of the National Fuel Gas Code ANSI Z223 1 or Canadian Installation Codes CAN CGA B149 Installer l appareil selon les codes ou r glements locaux ou en l absence de tels r glements selon les Codes d installation CAN CGA B149 CAUTION Do not operate the appliance with glass removed cracked or broken Replacement of the panel s should be done by a licensed or qualified se
6. codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 latest edition and CAN 1 B1 149 1 and 2 Installation Code Also for use in mobile manufactured homes after home is sited Mobile manufactured home installations must adhere to Title 24 CFR Part 3280 or CSA Z240 4 CAUTION This appliance must be vented to the outside Installation and repair of the Conquest Direct Vent Gas Stove should be done by a qualified ser vice person The appliance should be inspected be fore use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc Itis imperative that controlcompartments burn ers and circulating air passageways of the Conquest be kept clean Due to high temperatures the Conquest Direct Vent Gas Stove should be located out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they in the same room as the appliance Clothing or other flammable materials should not be placed on or near the appliance Surveiller les enfants Garder les vetements les meubles lessence ou autres liquides a vapeur inflammables lin de lappareil When operating your Harman Conquest Gas Stove respect basic safety st
7. switch wires and M bad EN Correct problem wiring connectors OK Replace valve 25 Only For Qualified Installers TROUBLE SHOOTING Optional Blower Label A BLOWER KIT PART NUMBER 1 00 09102 MANUFACTURED BY HARMAN STOVE COMPANY MAY BE USED WITH THIS CONQUEST DIRECT VENT GAS High altitude Conversion Label Canada Natural 0 Orifice Size 37 54 Pressure 3 8 WC 11 WC Input Btu h 27 500 27 500 29 Harman Gold Warranty 30 HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED HOT WARRANTY Residential 1 YEAR LIMITED WARRANTY Commercial WARRANTY Harman Stove Company warrants its products to be free from defects in material or workmanship in normal use and service for a period of 6 years from the date of sales invoice and for mechanical and electrical failures in normal use and service for a period of 3 years from the date of sales invoice If defective in material or workmanship during the warranty period Harman Stove Company will at its option repair or replace the product as described below The warranty above constitutes the entire warranty with respect to Harman Stove Company products HARMAN SIOVE COMPANY MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE No employee agent dealer or other person is authorized to give any warranty on behalf of Harman Stove Compan
8. 00 73148 28 3 31 03291 29 2 00 73143 1 2 30 2 00 73185 31 3 40 3849239 32 2 00 73156 33 3 20 08220 34 1 10 73149 35 1 10 73152W 36 2 00 73168 37 3 43 09101 FL 38 3 43 09101 ML 39 3 43 09101 40 3 43 09101 41 3 43 09101 FR 42 3 43 09101 F 43 2 00 73170 44 2 00 73154 45 3 20 09100 Right side panel Left side panel Spring clamp Spring clips Door springs Left amp right grill brackets Brick clips Flue collar Top brackets On off switch Flue cover weldment Top weldment Flue ring Far left tile Middle left tile Center tile Middle right tile Far right tile Flue tile jacket cover Andirons Wiring harness not shown 24 1 2 3 4 5 6 7 8 9 3 40 08715 2 00 73122 3 40 08220 3 31 09100 3 40 09106 3 31 08792 3 44 73174 3 90 4273 2 00 73125 MAINTENANCE Burner Parts LP pilot Igniter mount Igniter plezo 90 degree street elbow 50 turn down LP valve 1 2 flare fitting Valve gasket Gas label Sealer plate 10 3 40 09210 A 11 3 40 09210 B 12 1 10 73121 13 3 30 937161501 14 3 31 08284 15 3 50 02000 16 2 00 73124 17 3 40 09105 Hood orifice elbow 53 hood orifice Valve body weldment 3 8 elevator bolt 3 8 fitting Aluminum J tube Box top Burner tube 25 Only For Qualified Installers Look through hole in end of log to see if a spark jumps from the ignitor electrode to the pilot when the ignitor butt
9. Box Wall Thimble Cover 941 1241 Cathedral Ceiling Support Box 943 1243 Flashing 0 12 to 6 12 Roof Pitch 943S 1243S Flashing 7 12 to 12 12 Roof Pitch 953 1253 Storm Collar 963 1263 Ceiling Firestop 988 1288 Wall Strap 981 1281 Snorkel Termmation 36 982 1282 Snorkel Termmation 14 984 1284 Horizontal Square Termination 980 1280 Vertical Termination 991 1291 Vertical Termination High Wind 950 1250 Vinyl Siding Standoff 1222D Only available from Harman 8 x 5 to 63 x 4 Adaptor Only For Qualified Installers INSTAL LATION 1 1 This appliance must not be CONQUES T connected to a chimney flue Venting with 6 e X 4 Pipe serving a separate solid fuel burning appliance Maximum of four 45 elbows allowed amp S S S 2 mao Subtract three feet of total horizontal pipe Vent termination must remain within the length for each of the 3rd and 4th 45 elbows shaded area regardless of configuration used 4p Maximum of two 90 elbows allowed gt Subtract five feet of total horizontal pipe e e 7 length for second elbow D A combination of one 90 elbow and two 45 35 elbows is allowed e N VD Subtract three feet of total horizontal pipe E length for each 45 elbow used A snorkel termination is 30 _ recommended when no m vertical pipe is used 22 NE Z 20 WM 677 to 8 Increaser Only For Qualified Installers Requirements for Terminating the Venting
10. allation with Simpson Duravent GS venting com ponents The Simpson Duravent GS warranty will be voided and serious fire health or other safety hazards may result from any of the following actions Installation of any damaged Duravent GS component Unauthorized modification of the Duravent GS System Installation of any component part not manufactured or approved by Simpson Duravent Installation other than as instructed by Simpson Duravent and the appliance manufacturer Consult your local building codes before beginning the installation and follow the manufacturer s instructions exactly The Simpson Duravent GS venting components listed below are approved for use with the Conquest Direct Vent Gas Stove Part Numbers for SimpsonDura Vent Pipe and Fittings 6 5 8 x 4 8 x 5 Description n a 1208 6 Pipe Length 908B 1208B 6 Pipe Length Black n a 1207 9 Pipe Length 907B 1207B 9 Pipe Length Black 906 1206 12 Pipe Length 906B 1206B 12 Pipe Length Black 904 1204 24 Pipe Length 904B 1204B 24 Pipe Length Black 903 1203 36 Pipe Length 903B 1203B 36 Pipe Length Black 902 1202 48 Pipe Length 902B 1202B 48 Pipe Length Black n a 1211 11 to 14 5 8 Pipe Adjustable 911B 1211B 11 to 14 5 8 Pipe Adjustable Black n a 1217 17 to 24 Pipe Adjustable 945 1245 45 Elbow 945B 1245B 45 Elbow Black 990 1290 90 Elbow 990B 1290B 90 Elbow Black 940 1240 Rnd Support
11. andards Read these in structions carefully before you attempt to operate the stove Failure to do so may result in damage to property or personal injury and may void the prod uct warranty Consult with your local building code agency and insurance representative before you begin your installation to ensure compliance with local codes including the need for permits and follow up inspec tions Several issues must be addressed when select ing a suitable location for your Conquest Gas Stove Observing required clearances to combustible ma terials the proximity to a safe chimney or venting system location and the accessibility of the gas and electrical supply must all be considered In addition selecting a location that takes advantage of the building s natural air flow is also desirable to maxi mize the heating effectiveness of the stove In many cases this is a central location within the building Anysafety screenor guard removed for servicing an appliance must be replaced prior to operating the appliance This appliance may be installed in an after market permanently located mobile home Where not prohibited by local codes This appliance is only for use with the type s of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil peut etre installe dans un maison prefabriquee mobile deja installee a demeure si les reglements locaux le per
12. aximum alcove depth O gt Corner Clearances Alcove Clearances un V Q 2 ni Q e q lt un Only For Qualified Installers Burn Only the Fuel for which the Heater is Equipped The Conquest can burn either natural gas or pro pane but requires a change over kit for natural gas The label on the burner system module indicates the fuel for which it is equipped A second label on the valve also indicates the fuel type Making The Connection The gas inlet is located on the bottom right side of the stove The inlet fitting is a 1 2 male flare fitting A separate gas shut off valve and a 1 8 N P T plugged tapping should be installed immediately up stream of the connection to the appliance The Conquest Direct Vent Gas Heater must be disconnected from the gas supply piping during any pressure testing of that system at pressures in excess of 1 2 psig 3 5 kPa The Conquest gas control valve must be in the OFF position during any pressure testing of the gas supply system at pressures equal to or less than 1 2 psig 3 5 kPa WARNING To avoid pipe compounds from entering into the gas train apply compounds only to male pipe threads and do not apply compound to the first two threads CAUTION TEST ALL JOINTS FOR LEAKS BEFORE OPERATING Gas Pressure Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and
13. back up Pilot should remain lit If it goes out repeat steps 5 through 10 If the knob does not pop up when re leased stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 11 Turn the gas control knob counterclockwise to ON 12 Place the ON OFF switch in the ON position or turn up the thermostat setting if the optional thermostat is used 13 Turn on the electric power to the optional blower if installed 14 Set the optional thermostat to the desired room temperature OPERATION 6 Flame Height Adjuster Normal Flame pattern Note Flames will vary in height and position depending on the placement and the amount of ember wool 15 Set the High Low Regulator to desired setting Turn fully counterclockwise for High and fully clockwise for Low NOTE An odor resulting from the mitial heating of new materials in your heater is not unusual during the first fire and in most cases will disappear after an hour or two HOW TO TURN OFF THE FIRE 1 If using optional thermostat set thermostat to the lowest position 2 Turn off the electric power to the blower 3 Turn the ON OFF switch on the upper right rear of the stove to the OFF position 4 Push in the gas control knob slightly and turn it clockwise to OFF NOTE The knob cannot be turned from
14. corrosion and tight Inspect connections periodically to confirm that no corrosion has built up over time When properly installed and maintained a mil livolt control system should give many years of trouble free service It is important to use wire of a gauge proper for the length of the wire Thermostat RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 Burner Button 40 18 25 20 15 22 Remote Control Kit The button on the remote control can be used to turn the fire on and off This remote uses the ultrasonic control method and does not need to be pointed directly at the fire place The kit mcludes installation instructions a hand held sending unit receiving unit mounting bracket and all wiring Note The ON OFF switch must be OFF when using the remote If the switch is m the ON position the fire will stay on even when the set tem perature on the thermostat is reached Glass Grill To install the glass grill remove the door and slide the top of the vertical bars up into the slots at the top of the firebox opening Lower the grill down so the bottom of the vertical bars rest Just inside the lip at the bottom of the firebox opening Reinstall door Glass Grill Power Cord N A ak tak Bak Bak ah ak f ru ted de A nl e Blower Chamber Cover Optional Blower The Blower Kit Part 1 00 09102 includes a blower a
15. e conversion sticker provided in Kit on the valve This is to permanently mark the valve that it has been converted to Natural Gas This label is important in the event that the valve is ever removed and mixed in with other valves D Mark the proper box on the label with a permanent marker Note If no conversion 1s made the box for the propane box must still be marked by the installer Verify gas inlet and manifold pressures are within the specifications on the appliance data plate located inside the bottom of the unit Only For Qualified Installers INSTAL LATION 16 Log Placement Rear Log e S P i d Place the front log as shown between the andirons and the air deflector Place the rear log behind the front log with the branch resting on the front log on the right side as shown Before lighting a fire check that the rear log is as far back against the rear wall as possible The front log should be slide rearward in its position between the andirons and deflector plate Ember Placement After the logs are positioned place the embers as shown above There are two types of embers supplied One is a wool like material and the other like a nugget The wool is to be placed on the screen by pull ing small pieces from the bunch with your fingers or a tweezers Place the wool lightly on the screen over the horse shoe tube area Be careful not to compact the wool The looser and fluffierthe bet
16. efficient performance of this appliance Make sure that the plumber or gas supplier checks the gas sup ply line and gas pressure at installation NOTE Improper gas pressure can affect heater performance flame color or cause pilot outage INSTALLATION 9 Natural Gas Maximum inlet pressure 7 0 w c 1 74 kPa Minimum inlet pressure 5 0 w c 1 25 kPa Gas manifold pressure 3 8 w c 0 87 kPa LPG Gas Maximum inlet pressure 13 w c 3 24 kPa Minimum inlet pressure 11 5 w c 2 74 kPa Gas manifold pressure 11 w c 2 49 kPa DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOISTURE CORROSION IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER RECOMMENDED GAS PIPE DIAMETER Schedule 40 Pipe Diameter 1 2 dd 1 3 cm ds Pipe Length Feet Tubing Type L Fr Di a 3 8 cm 1 0 1 2 5 8 1 2 1 3 3 cm 1 6cm 1 3 1 2 1 2 3 4 1 2 13cm 1 3 cm 16cm 1 3 cm 3 4 1 2 7 8 2 0cm 1 3cm 2 3 cm NOTE NEVER USE PLASTIC PIPE CHECK TO CONFIRM WHETHER YOUR LOCAL CODES ALLOW COPPER TUBING OR GALVANIZED PIPE 1 2 1 3 3 4 2 0 LABEL THE BURNER SYSTEM MODULE STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED INSTALLATION 10 Only For Qualified Installers Use Only Approved Venting This appliance has been tested and is listed for inst
17. ings Natural Gas or Propane 0 Feet rear Vent Open 6 feet 1 4 to Open 12 feet 1 4 to Open 24 feet Closed to 1 2 36 feet Closed to 1 2 13 Only For Qualified Installers INSTAL LATION 1 4 Changing to Natural Gas Natural Gas Conversion Kit _ Remove four bolts and remove burner ux NG Orifice 37 FET SST NG Conversion label NG Pilot Orifice module from NG Valve Conversion Module i installation NG Conversion 820 NOVA Instructions G Use a 1 2 deep well Natural Gas Kit Part No 1 00 09112 socket to remove the LP 53 orifice and replace x with the 37 Natural gas orifice from the kit J This kit is only for use in the Conquest direct vent gas stove Remove pilot tower with AX a 7 16 wrench Replace gc 4 P oroi a Remove the three screws that hold the Gas OEC ee S 3 LP knob module in place Remove the module and replace with the Natural gas module from the kit See kit instructions Only For Qualified Installers Reinstall burner module back into the stove with the four bolts that were removed Check gasket for damage and replace if necessary Check for gas leaks when finished INSTALLATION 15 Note The higher the orifice number the smaller hole in the tip For example a number 52 orifice has a larger hole than a number 60 orifice 6 Plac
18. mettent Cet appareil doit etre utilise uniquement avec les types de gas indiques sur la plaque signaletique Ne pas 1 utiliser avec d autres gas sauf si un kitde conversion dertifie est installe OPERATION 5 Operation HOW TO LIGHT THE FIRE 1 STOP Read the safety information on the front cover of this manual 2 If using the optional thermostat set thermostat to the lowest setting 3 Turn off electric power to the optional blower Turn the ON OFF switch to the OFF position 5 Push in the gas control knob slightly and turn it clockwise to NOTE THE CANNOT BE TURNED FROM PILOT TO OFF UNLESS IT IS PUSHED IN SLIGHTLY DO NOT FORCE IT 6 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information on the front cover If you don t smell gas go to the next step 7 Set the High Low Regulator to High by turning it fully counterclockwise 8 Press in the gas control knob slightly and turn 4 Piezo Ignitor counterclockwise to PILOT VA Button 9 Find the pilot by looking down between the logs as shown at lower left 10 Push control knob fully down hold Immediately push the red piezo ignitor button to light the pilot It is normal to have to push the red button several times before the pilot ignites Continue to hold the control knob in for about one 1 mmute after the pilot 15 lit Release knob and it will pop
19. nd outer pipes of the venting system should be made during the annual service appointment There must be no block age and be in good repair The vent manufacturer s instructions may provide specific suggestions or details on vent inspection Any sections that are taken apart for the inspection must be reassembled and sealed as required Cleaning the Log Set and Firebox During the annual inspection and maintenance appointment the service person should clean dust lint and any light accumulation from the logs and the firebox area An extra soft brush should be used on the logs as they are extremely fragile a vacuum cleaner may be used on the firebox If at any time the logs cannot be removed or installed without forc ing the cause must be found The logs must never be forced Air Flow It is essential that the air flows freely into the blower and out of the top grill Do not place objects in front of the grill Check blower annually for buildup caused by dust and pet hair Cleaning the Burners To clean the burners you must remove the glass door logs and burner screen With these parts removed inspect all the holes to make sure they are unobstructed Use a small drill or wire to clean any obstructed holes Remove any rust or other buildup that may have accumulated on the burner or screen Replace parts in reverse order MAINTENANCE 22 Optional Blower Wiring Low Voltage Wiring Diagram 120 Volt Diagram Temperature
20. nded three prong receptacle Do not cut or remove the grounding prong from the plug MAINTENANCE Gold Frame A qualified service person should conduct an annual inspection and maintenance of your Conquest its venting and the installation to keep it running safely and efficiently The fol lowing procedures should be performed only by a qualified service person The gas supply should be turned off whenever a maintenance procedure is performed If the glass door or side doors are removed for servicing they must be replaced prior to operating the stove Latch CAUTION Do not operate this appliance with the glass front removed cracked or broken Replacement of glass should be done by a licensed or qualified service person Never use substitute materials CAUTIONNER N op re l appareil avec le verre enl ve craque ou casse Le remplacement du panneau s devrait tre fait par une personne de service qualifi ou autoris Removing the Glass Front Remove the air grill by pulling forward Lift the latch shown above and tilt the glass door Door Gasket DO NOT STRIKE OR SLAM GLASS Replacing the Gasket The Conquest uses part no 3 44 00539 fiber glass gasket in the front door Should it ever need replacement use only the proper replacement gas ket that is available from your Harman dealer Re place the gasket as follows 1 8 Lay glass door face down on a soft surface tha
21. nting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or battery back up and related duct work are not covered Also excluded from this warranty are consumable or normal wear items including but not limited to flame guides grates coal bars afterburner hoods fire brick gaskets Additional exclusions for corn stoves are burnpot housing weldment burnpot grate weldment pellet or corn burnpot front plate pellet or corn burnpot front plate lock corn auger extension ceramic insert and ceramic insert plate Additional or unusual utility bills incurred due to any malfunction or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered Maintenance needed to keep the stove in good operating condition is not covered This includes but is not limited to cleaning adjustment of customer controls and customer education Labor materials expenses and or equipment needed to comply with law and or regulations set forth by any governmental agencies are not covered This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state In the event of change in ownership the remaining portion of this warranty may be transferred to the new owner by sending
22. on is pushed Yes Is gas turned Yes Is there gas in tank LP or line NG Yes Purge gas line to stove OK Check pilot orifice and pilot line for blockage TROUBLE SHOOTING NO NO Pilot does not light after many tries Check ignitor wire and connections from piezo ignitor to ignitor ceramic at pilot Check Ignitor Ceramic for cracks Check Piezo Ignitor to make sure the small wire on the mounting flange is grounded OK Replace Piezo Ignitor Turn on gas valve Replenish supply Bad Reconnect or replace Ignitor wire Bad Replace Bad Clean paint or rust from around mounting hole 26 Only For Qualified Installers Check inlet pressure Good Check size of pilot flames Good TROUBLE SHOOTING Pilot does not stay lit Bad Correct inlet pressure Bad Adjust pilot adjustment to achieve proper flame Check Milivolt output of ___ B ad Replace Thermocouple thermocouple Should be 10 or more MV Replace Valve 27 Only For Qualified Installers TROUBLE SHOOTING Main Burner will not light with valve in position Is Pilot lit no Light pilot Yes Check Thermopile voltage at terminals marked TP on valve Should be approximately too low Replace Thermopile 200 mv with switch and approximately 400 mv with switch off Check
23. rvice person WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Open windows Extinguish any open flame Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified gas installer service agency or the gas supplier Table of Contents Introduction Safety Precautions Operation Specifications Clearances Installation Venting Changing To Natural Gas Option Installation Thermostat Remote Control Glass Grill Blower Maintainence Wiring Diagram Parts Trouble Shooting Manufactured by The Harman Stove Company 352 Mountain House Rd Halifax PA 17032 USA Introduction The Harman Conquest Direct Vent Gas Stove 5 a listed gas fired direct vent room fireplace tested by Intertek Testing Services Warnock Hersey to ANSI Z21 88 2002 CSA 2 33 M02 and CANL CGA 2 17 M91 The installation of the Conquest Direct Vent Gas Stove must conform with local
24. ssembly ready to bolt to the left side of the stove and a blower chamber cover The blower has a variable speed control knob to adjust the blower speed as desired A special switch is used to automatically start the blower when the stove temperature is hot enough to blow warm air This switch will also stop the blower when the stove temperature drops below the point that warm air is available Installation 1 Open the left side panel 2 Remove the four screws from the left side of the firebox with a 7 socket Place the blower as shown and start the top screw This will hold the blower in place and make it easier to install the other three screws 4 Route the power cord rearward between the side panel and the pedestal and plug into a 120 volt outlet 5 Open the right side panel and remove the two screws on the right side of the firebox 6 Use the two screws to fasten the blower cham ber cover plate to the firebox This plate pre vents air from the blower escaping from the air chamber 7 Close side panels UI Operation Turn the speed control knob clockwise until it clicks This is the full speed position Turning the knob farther in the clockwise direction will gradu ally reduce the blower speed To turn the blower OFF turn the knob counterclockwise until it clicks This blower is equipped with a three prong grounding plug for protection against shock hazard and should be plugged directly into a properly grou
25. t 2 1 m M The clearance under a veranda porch deck or balcony must be a minimum of 12 inches 30 cm As specified in CAN 1 B1 149 Installation Codes current edition Note Local codes or regula tions may require different clearances 2 vent shall not terminate directly above a side walk or paved driveway which is located between two single family dwellings and serves both dwell ings Only permitted if veranda porch deck or bal cony is fully open on a minimum of 2 sides beneath the floor 2 77 273 ZU Inside Correr Detail O Air supply inlet 8 Fixed Closed TERI LE Z TT B K Area where terminal is permitted Z Only For Qualified Installers INSTAL LATION Damper Settings Top Vent Only Vent damper shown in the Maximum Draft OPEN position for top vent Note This would be the Minimum Draft CLOSED position if a rear vent was installed A vent damper is provided to allow fine tuning of the draft Too little draft will cause flames to be too long with black tips and too much draft will cause flames to be short and blue To adjust the damper burn the unit on High 10 minutes or more Adjust the vent damper to a posi tion in the ranges listed below that produces the most desirable flame pattern Note 1 is less draft and 4 is maximum draft Range Of Approved Damper Sett
26. t will not scratch the glass Remove the nuts holding the top and bottom glass clip in place Remove glass from door and remove old gasket Install new gasket around glass Place glass back in door Reinstall glass clips and tighten the nuts Remstall glass door by placing the slots on the bottom of the door over the hooks on the bot tom of the door opening Next lift the latch and push the door against the unit Pull the spring loaded latch front until the tab drops into the slot on the door frame Reinstall air grill Cleaning the Glass The glass may be cleaned with ordinary house hold glass cleaner and a soft cloth or paper towel WARNING Never clean the glass when it is out at the top and lift off the hooks at the bottom hot Do not use abrasive cleaners on the glass Handle the glass with care MAINTENANCE The flow of combustion and ventilation air must not be obstructed The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean If the vent air intake systemis disassembled for any reason reinstall per the instructions provided for the initial installation 21 Inspecting the Venting An inspection of both the inner a
27. ter The place ment and density of the wool changes the front flames and glowing embers You can try different placement to get the look you prefer Place nuggets where desired elsewhere in front of the log Only For Qualified Installers a i INSTALLATION Round Tile Not Used On Top Vent Vent Trim Ring Not Used On Rear Allen Set 17 Tile Kit Each tile kit contains six tiles and fifteen allen set screws If the Conquest is installed as a top vent then the round tile is not used If it 1s installed as a rear vent then the trim ring is not used Installing Tiles Below each tile opening are three threaded holes In some cases it may be helpful to remove extra paint from the treads with a 1 4 20 tap 1 Screw the set screws down until the top of the screw is about the thickness of the tile below the top surface 2 Place the proper tile in the opening 3 Observe the level of the tile If the level of the tile is not satisfactory remove the tile by press ing down on one of the corners and adjust set screws accordingly Only For Qualified Installers INSTALLATION Options 18 Connecting the Optional Thermostat If the optional thermostat is used it must be plugged into the TH terminals located on the valve When installing a millivolt control system use only a special low resistance thermostat DO NOT USE REGULAR HEATING THERMOSTAT Be sure that all electrical connections are clean free from
28. the new owner information and a transfer fee of 25 00 US to the Harman Stove Company PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DEVICES THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES NOT HARMAN STOVE COMPANY OR THEIR WARRANTY ADMINISTRATOR FURTHERMORE THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFAC TURER REMEDIES The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith whether 1n Contract in tort under any warranty or otherwise shall not except as herein expressly provided exceed the price of the equipment or part of which such liability 1s based CLARIFY The above represents the complete warranty which is given in connection with stoves manufactured by Harman Stove Company No other commitments verbal or otherwise shall apply except by a written addendum to this warranty
29. y This warranty does not apply if the product has been altered in any way after leaving the factory Harman Stove Company and its agents assume no liability for resultant damages of any kind arising from the use of its products In addition the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation proper or improper of the equipment THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user s manual THESE WARRANTIES WILL NOT APPLY if abuse accident improper installation negligence or use beyond rated capacity causes damage HOW TO MAKE A CLAIM Any claim under this warranty should be made to the dealer from whom this appliance was purchased Then contact is made with manufacturer giving the model and serial numbers the date of purchase your dealer s name and address plus a simple explanation of the nature of the defect Extra costs such as mileage and overtime are not covered Nuisance calls are not covered by these warranties THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS REPAIR AND OR REPLACEMENT AT HARMAN STOVE COMPANY S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH WARRANTY EXCLUSIONS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and ve