Home

Hans Grohe 26017XX1 Plumbing Product User Manual

image

Contents

1. The panel height may be increased if desired The measurements shown on page 5 must be increased accordingly including the minimum ceiling height Thoroughly flush the hot and cold water supplies before installing the showerpanel Installation Wrap the threads on the nipples with Teflon tape Install the elbows The elbow outlets should face downward A Seal the wall around the elbows with waterproof sealant D Failure to seal the wall can lead to possible water damage Drill the holes for the mounting screws with an 8 mm bit A Do not drill into water lines Install the anchors A Seal the wall around the anchors with waterproof sealant O Failure to seal the wall can lead to possible water damage Install the screws Install the nuts There should be 9 16 between the rear of the nut and the surface of the wall Hang the panel over the top screws only 1 With a partner holding the panel out of the way Install the panel supply hoses on the elbows Tighten the hose nuts 2 Raise the panel 3 Push the bottom of the panel over the bottom screws 4 Lower the panel 5 so that the screws are in the narrow parts of the keyways Tighten the nuts using a 10 mm wrench Place the handshower in the holder Place a black rubber hose washer in one end Install the top cover of the handshower hose Install th
2. nts GOL Y dr Pharo Skyline 26017XX1 ansgrone Pharo Skyline Showerpanel 26017XX1 Technical Information showerhead Recommended water pressure 14 7 72 5 psi Minimum water pressure 29 psi Max water pressure 147 psi Recommended hot water temp 120 140 F Max hot water temp 165 F Max flow rate showerhead 2 5 gpm handshower 2 5 gpm neck spray 2 5 gpm bodysprays 0 72 gpm each e Thermostatic temperature control e The high temperature limit stop on the thermostatic mx ing valve may be reset to comply with local plumbing codes e Protection against back siphonage provided by check valves The check valves should be removed and handshower inspected yearly e This panel may be used with an instantaneous water heater if the heater is at least 24 kW and the output is at least 3 gpm 30 psi pressure However only one panel function may be used at a time Please know and follow all applicable local plumbing codes when setting the temperature on the water heater In Massachusetts the water heater bodysprays may be set no higher than 112 F Installation Considerations e For best results Hansgrohe recommends that this unit be installed by a licensed professional plumber Please read over these instructions thoroughly before beginning installation Make sure that you have all tools and supplies needed to complete the installation e A minimum of two people is required to
3. shampoos and shower foams can also cause damage so rinse with clean water after using Please note If the surface is already damaged the effect of cleaning materials will cause further damage Components with damaged surfaces must be replaced otherwise this could cause an injury Damage caused by improper treatment is not covered by our warranty Limited Lifetime Consumer Warranty This product has been manufactured and tested to the highest quality standards by Hansgrohe Inc Hansgrohe This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1 1996 and installed in either the United States or Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only This warranty is non transferable WHAT IS COVERED BY THE WARRANTY This warranty covers only your Hansgrohe manvfactured product Hansgrohe warrants this product against defects in material or workmanship as follows Hansgrohe will repair at no charge for parts only or at its option replace any product or part of the product that proves defective because of improper workmanship and or material under normal installation use service and maintenance If Hansgrohe is unable to provide a replacement and repair is not practical or cannot be timely made Hansgrohe may elect to refund the purchase price in exchange for the return of the product LENGTH OF WARRANTY Replacement or repaired
4. install IN this panel Do not attempt to install this panel alone as injury or damage to the panel may result neck spray foot rest p Cr Suggested installation 162 133 A BEZA I I i 95 110 A 61A pat i 130 e E E gt i ap A o E Sr S Ri aL oo uy A B La 4 tl A gt 1 8 X io ieee eH 4 o Za oo A RS o e R 8 q 5 i o Es o Le Y x 3 3 a a R HU i Kd E 11 Le pror d Minimum ceiling height 86 5 8 Package Contents Please check the package contents before beginning installation If parts are missing or are not in good condition please contact Hansgrohe Technical Service Rough in Install 1 2 NPT male nipples at the positions shown on the rough in diagram for the hot and cold water supplies The nipples should extend 5 8 outside the surface of the finished wall Install the finished wall surface Make the wall watertight The showerpanel will hang on the finished wall The measurements shown on page 5 are for the suggested installation shown on page 3 which is ideal for users of approximately 5 11 in height The minimum ceiling height for this installation is 86 5 8
5. not apply to you This warranty gives you specific legal rights and you may have other rights which vary from State to State You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson Moss Warranty Act PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation please carefully inspect your Hansgrohe product for any damage or visible defect Prior to installing always carefully study the enclosed instructions on the proper installation and the care and maintenance of the product If you have questions at any time about the use installation or performance of your Hansgrohe product or this warranty please call or write to us or call us toll free at 800 334 0455 ansgrone Hansgrohe Inc 1490 Bluegrass Lakes Parkway Alpharetta GA 3XX04 Tel 770 360 9880 e Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90431331 Revised 12 2007
6. temperature Thermostatic mixer cartridge faulty Replace thermostat cartridge Function drips won t shut off Volume control cartridge faulty Replace volume control cartridge completely Hot water bleeds over into cold Faulty check valve Remove and clean check valve water supply in house or vice replace if necessary versa Limited Lifetime Consumer Warranty This product has been manvfactured and tested to the highest quality standards by Hansgrohe Inc Hansgrohe This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1 1996 and installed in either the United States or Canada WHO IS COVERED BY THE WARRANTY This warranty extends to the original consumer purchaser only This warranty is non transferable WHAT IS COVERED BY THE WARRANTY This warranty covers only your Hansgrohe manufactured product Hansgrohe warrants this product against defects in material or workmanship as follows Hansgrohe will repair at no charge for parts only or at its option replace any product or part of the product that proves defective because of improper workmanship and or material under normal installation use service and maintenance If Hansgrohe is unable to provide a replacement and repair is not practical or cannot be timely made Hansgrohe may elect to refund the purchase price in exchange for the return of the product LENGTH OF WARRANTY Replacement or repaired parts of products
7. warranty gives you specific legal rights and you may have other rights which vary from State to State You may be required by law to give us a reasonable opportunity to correct or cure any failure to comply before you can bring any action in court against us under the Magnuson Moss Warranty Act PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation please carefully inspect your Hansgrohe product for any damage or visible defect Prior to installing always carefully study the enclosed instructions on the proper installation and the care and maintenance of the product If you have questions at any time about the use installation or performance of your Hansgrohe product or this warranty please call or write to us or call us toll free at 800 334 0455 ansgrone Hansgrohe Inc e 1490 Bluegrass Lakes Parkway e Alpharetta GA 30004 Tel 770 360 9880 e Fax 770 360 9887 www hansgrohe usa com US Installation Instructions Part No 90431321 Revised 12 2007 Pharo Skyline ansgrone Technical Information Recommended water pressure 14 7 72 5 psi Minimum water pressure 29 psi Max water pressure 147 psi Recommended hot water temp 120 140 F Max hot water temp 165 F Max flow rate showerhead 2 5 gpm handshower 2 5 gpm neck spray 2 5 gpm bodysprays 0 72 gpm each e Thermostatic temperature control e The high temperature limit stop on the thermostatic mixing v
8. Accessories connected materials and products or related products not manvfactured by Hansgrohe TO OBTAIN WARRANTY PARTS OR INFORMATION Contact your Hansgrohe retailer or contact Technical Service at Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta GA 3XX04 Tollfree 800 334 0455 In requesting warranty service you will need to provide 1 The sales receipt or other evidence of the date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 3XX04 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND LIMITATIONS REPAIR OR REPLACEMENT OR IN LIMITED CIRCUMSTANCES REFUND OF THE PURCHASE PRICE AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER HANSGROHE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY PERSON FOR ANY INCIDENTAL SPECIAL OR CONSE QUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING MERCHANTABILITY Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclu sion may
9. alve may be reset to comply with local plumb ing codes please refer to the installation instruction manual e Protection against back siphonage provided by check valves The check valves should be removed and inspected yearly see page 8 e This panel may be used with an instantaneous water heater if the heater is at least 24 kW and the output is at least 3 gpm 30 psi pressure However only one panel function may be used at a time Please know and follow all applicable local plumbing codes when setting the temperature on the water heater In Massachusetts the water heater may be set no higher than 112 F showerhead neck spray T handshower bodysprays foot rest mA User Instructions Turn the top volume control clockwise to obtain water from the overhead shower Turn the top volume control counter clockwise to obtain water from the neck spray It is not possible to run the overhead shower and the neck spray simultaneously Turn the bottom volume control clockwise to obtain water from the handshower Turn the bottom volume control counter clockwise to obtain water from the bodysprays It is not possible to run the handshower and bodysprays simultaneously The following combinations may be used by turning on each function with the volume control e Overhead shower and handshowe
10. aterials and products or related products not manufactured by Hansgrohe TO OBTAIN WARRANTY PARTS OR INFORMATION Contact your Hansgrohe retailer or contact Technical Service at Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta GA 30004 Tollfree 800 334 0455 In requesting warranty service you will need to provide 1 The sales receipt or other evidence of the date and place of purchase 2 A description of the problem 3 Delivery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND LIMITATIONS REPAIR OR REPLACEMENT OR IN LIMITED CIRCUMSTANCES REFUND OF THE PURCHASE PRICE AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER HANSGROHE NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO CREATE FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THIS PRODUCT HANSGROHE SHALL NOT BE LIABLE TO PURCHASER OR ANY PERSON FOR ANY INCIDENTAL SPECIAL OR CONSE QUENTIAL DAMAGES ARISING OUT OF BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY INCLUDING MERCHANTABILITY Some States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclu sion may not apply to you This
11. d showers consist of very different materials to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning When cleaning fittings and showers keep the following in mind e Only use cleaning materials intended for this purpose Never use cleaning materials which contain hydrochloric acid formic acid chlorine pale lye or acetic acid as they cause considerable damage Phosphoric acidic cleaners are only conditionally applicable Do not mix cleaning products unless instructed to do so by the cleaning material manufacturer Never use cleaning materials or appliances with an abrasive effect such as unsuitable cleaning powders sponge pads or micro fiber cloths e Always follow the instructions provided by the manufacturer of the cleaning product Be sure to use the correct amount of cleaner and leave it in contact with the fitting for the correct amount of time e The buildup of limescale and hard water spots should be prevented by regular cleaning e When using spray cleaners spray first onto a soft cloth or sponge never directly onto the fitting as drops could enter openings and gaps and cause damage e After cleaning rinse the fitting thoroughly with clean water to remove any cleaner residue e The use of steam cleaners is not permitted The high temperatures can damage fittings Important Residues of liquid soaps
12. he incorrect elbows elbows Insufficient water Filters inside supply elbows Remove and clean filters clogged Erratic water temperature Thermostatic mixer cartridge faulty Replace thermostat cartridge Function drips won t shut off Volume control cartridge faulty Replace volume control cartridge completely Hot water bleeds over into cold Faulty check valve Remove and clean check valve water supply in house or vice replace if necessary versa Maintenance Note The check valves located in the hot and cold elbows should be removed and inspected yearly If the flow of water decreases over time clean the filters Cy filter S check valve Replacement Parts 98875XX0 E 28532XX1 28276XX0 A 94074000 97582000 ES Sf 00 trc CD 6 00 0 COO EC 1 o nO wa 9408200 98744000 98743000 98877000 98876000 Pi 98881001 EI C Bn vr m 3 E 98900001 E 9887900 E 98878000 BEC wl A J ASE 98884000 98880000 A d 98901001 A 98891XX0 97342XX0 7889 TXXO 96509000 97441XX0 94282000 98742XX0 98883000 98884000 A XX color a S 00 chrome y 82 brushed nickel Cleaning Recommendation for Hansgrohe Products Modern lavatory faucets kitchen faucets an
13. is end of the hose on the handshower outlet Place the screen washer in the other end of the hose Connect this end of the hose to the handshower Reset the High Temperature Limit Stop Optional if required by local code Remove the thermostatic mixer handle and safety set Remove the clip and stop ring from the thermostatic mixer stem Turn the water on to the handshower Turn the stem until the output water is the desired maximum high temperature usually 110 F 112 F Turn the water off Reinstall the stop ring so that the tooth is against the stop Reinstall the clip Justify and install the handle Justify the handle Turn the water on to the handshower Turn the thermostatic mixer handle until the output water is 100 F Turn the water off Remove the thermostatic mixer handle and safety set Reinstall the safety set so that the notch is at the 12 00 position Reinstall the handle with the safety stop override but ton at the 12 00 position Tighten the screw fully then loosen it 1 4 1 2 turn Install the screw cover Troubleshooting Problem Possible cause Solution Outputs both hot and cold water Supply lines connected to the Reconnect supply lines to correct but no mix incorrect elbows elbows Insufficient water Filters inside supply elbows Remove and clean filters clogged Erratic water
14. parts of products will be covered for the term of this warranty as stated in the following two sentenc es If you are a consumer who purchased the product for use primarily for personal family or household purposes this war ranty extends for as long as you own the product and the home in which the product is originally installed If you purchased the product for use primarily for any other purpose including without limitation a commercial purpose this warranty extends only i for 1 year with respect to Hansgrohe and Commercial products and ii for 5 years with respect to AXOR products 10 THIS WARRANTY DOES NOT COVER AND HANSGROHE WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmanship B Conditions malfunctions or damage resulting from 1 normal wear and tear improper installation improper mainte nance misuse abuse negligence accident or alteration or 2 the use of abrasive or caustic cleaning agents or no rinse cleaning products or the use of the product in any manner contrary to the product instructions 3 Conditions in the home such as excessive water pressure or corrosion C Labor or other expenses for the disconnection deinstallation or return of the product for warranty service or for installa tion or reinstallation of the product including but not limited to proper packaging and shipping costs or for installation or reinstallation of the product D
15. r e Overhead shower and bodysprays e Neck spray and handshower e Neck spray and bodysprays Using the thermostatic mixer Turn the thermostatic mixer handle clockwise to make the water cooler Turn it counter clockwise to make it warmer The handle will stop at the 100 safety stop To override the safety stop press the override button and continue turning the handle counter clockwise Open the overhead shower and neck spray To open the overhead shower and neck spray press the lower left hand corner of the cover To open the footrest press the upper left corner of the cover The showerhead will open to the 95 position Push it upward to the 110 position if desired Adjust the showerhead cover If the showerhead or neckspray cover does not hang straight loosen or tighten the set screw with a 3 mm Allen wrench to correct Cleaning the hand and overhead showers The handshower and overhead shower use the Rubit M self cleaning system If scale deposits are noticed in the spray channels turn the water on lightly and rub over the channels with a finger or a sponge to dislodge them Troubleshooting Problem Possible cause Solution Outputs both hot and cold water Not a product defect Supply Reconnect supply lines to correct but no mix lines connected to t
16. will be covered for the term of this warranty as stated in the following two sentenc es If you are a consumer who purchased the product for use primarily for personal family or household purposes this war ranty extends for as long as you own the product and the home in which the product is originally installed If you purchased the product for use primarily for any other purpose including without limitation a commercial purpose this warranty extends only i for 1 year with respect to Hansgrohe and Commercial products and ii for 5 years with respect to AXOR products THIS WARRANTY DOES NOT COVER AND HANSGROHE WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmanship B Conditions malfunctions or damage resulting from 1 normal wear and tear improper installation improper mainte nance misuse abuse negligence accident or alteration or 2 the use of abrasive or caustic cleaning agents or no rinse cleaning products or the use of the product in any manner contrary to the product instructions 3 Conditions in the home such as excessive water pressure or corrosion C Labor or other expenses for the disconnection deinstallation or return of the product for warranty service or for installa tion or reinstallation of the product including but not limited to proper packaging and shipping costs or for installation or reinstallation of the product D Accessories connected m