Haier AP602AKEAA Air Conditioner User Manual

image

Contents

1. Cut away with a hammer or a saw the lid for piping according to piping direction Insulation material AAS According to the piping method connect the piping on indoor unit with union of connecting pipe Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping together with polyethylene tape Insert the bound piping connecting electric cable and drain hose through wall hole to connect with outdoor unit Drain hose Connecting electric cable for indoor and outdoor unit Copper tube 24 Installation procedures Arrangement of drain hose Drain hose shall be placed in under place There should be a slope when arrange drain hose Avoid up and down waves in drain hose Indoor unit RA x Slope Good Down Bad If humidity is high drain pipe especially in room and indoor unit must be covered with insulation material 3 Piping connection of outdoor unit Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method 4 Purging method Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing 1 Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage 2 Under the condition of the complete close of the indoor and outdoor valve center both liquid and gas side dismount the repair valve cap Vacuumizing through the charge mouth of the repair valve 3 Aft
2. Such means for disconnection must be incorporation in the fixed wiring 3 Charge over switch For AP482AKEAA the charge over switch is set BM1 1 OFF 2 2 1 OFF 20FF 3 OFF 4 OFF BM3 1 OFF 20FF 3 OFF 4 OFF BM4 1 OFF 2 ON For AP602AKEAA the charge over switch is set BM1 1 OFF 2 ON BM2 1OFF 2 OFF 3 OFF 4 OFF BM3 1OFF 2 OFF 3 OFF 4 OFF BM4 1 OFF 2 ON 19 Indoor amp outdoor unit connection pipe direction Right Bottom 20 Tools necessary Tools necessary Screw driver Hacksaw 7Omm dia hole core drill Spanner dia 22 36mm Spanner 16 18 22 36mm Pipe cutter Flaring tool Knife Nipper 0 Gas leakage detector or soap water 11 Measuring tape 12 Reamer 13 Refrigerant oil 1 2 3 4 5 6 7 8 9 1 Standard accessories Following parts shall be field supplied Mark Parts name A Adhesive tape Pipe clip O Connecting hose D Insulation material B Putty Drain hose 21 Installation procedures Display of whole unit O Try to bring the packed unit to the installation place C When it is inevitable to unpack the unit be careful not to damage the unit Wrap it with nylon etc O After unpacking be sure to put it with the front side of the unit faci
3. In heating operation indoor fan won t stop even if unit is stopped To prevent frost from accumulating on indoor heat exchanger unit will switch to fan operation for a while then resume cooling operation Though ON OFF button is set to ON unit won t resume cooling dry or heating operation in 3 min after it is stopped this is because of 3 min delay protection circuit iN Please wait 3 minutes Unit will reduce fan speed repeatedly and automatically if room temp is too low in dry operation This occurs when frost accumulated on the outdoor unit is removed during defrosting operation After unit stops indoor fan will go on running until indoor unit cools down 17 When problems occur Before asking services please firstly check your unit according to following Air conditioner won t start Is power supply switch Is city power supply normal turned on Power supply switch is not set at ON Is leakage current breaker activated This is very dangerous please disconnect power supply immediately and contact your dealer Poor cooling or heating Are operation controlls Is air filter too dirty adjusted correctly as specified IAE Are there any obstacles at inlet or outlet grill Ir Are horizontal louvers Any doors or windows left at up position in open heating mode D Is there any direct sunlight
4. Note The waster batteries should be disposed properly use two new same type batteries when loading If the remote controller can t function normally or doesn t work at all use a sharp pointed item to press the reset key Hint Remove the batteries in case unit won t be in usage for a long period If there are any displays after taking out just need to press reset key When throw away the waste batteries please perform in accordance with the local regulation Operation ON OFF FAN TEMP TEMP HEALTH Control panel Remote control unit H rate E 6 G J controller AUTO COOL DRY FAN HEAT Control panel gt 3E AUTO COOL DRY FAN HEAT Then select AUTO run or select COOL operation or select DRY operation or select HEAT operation 3 Select temp button Press TEMP button TEMP A Every time the button is pressed temp setting increases 1 C TEMP W Every time the button is pressed temp setting decreases 1 C If the button is kept pressed setting will increase or decrease quickly Press FAN For each press operation mode changes as follows HEAT Remote at a uii WITT controller LOW MID HIGH _ AUTO LIGHT LOCK Control pum Con mumm memmen panel LOW HIGH Part 1 to 4 bright periodically Unit runs at the speed displayed on LCD When fan speed is AUTO it is changed automatically according to the indoor temperature Press ON OFF button Unit
5. an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon All these valuable materials may be taken to a waste collecting center and used again after adequate recycling Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guide carefully The User s Guide contains very important observations relating to the assembly operation and maintenance of the air conditioner The manufacturer does not accept responsibility for any damages that may arise due to non observation of the following instruction Damaged air conditioners are not to be put into operation In case of doubt consult your supplier Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User s Guide e Installation shall be done by professional people don t install unit by yourself Fo
6. obstacles at inlet and outlet of indoor and outdoor unit whick will reduce unit efficiency Don t fail to attach air filter after making sure it is cleaned Dust will enter into unit causing damages or faults if it is running without air filter To protect compressor at start please connect external power supply to the unit 12 hrs prior to starting Also please keep the power supply switch ON during the whole season 16 Trouble shooting Followings are not problems Sound of water flowings are not problems Sound of cracking is heard Smells are generated During operation white fog or steam comes out of indoor unit During unit start and operation or at stop a swishing or gurgling noise may be heard This noise is generated by refrigerant flowing in the system During unit operation a cracking noise may be heard This noise is generated by the casing expanding or shrinking because of temperatuer changes This is because the system circulates smells from the interior air such as the smell of cigarettes or the painting on the unit When unit is running at places like restaurant where dense edible oil fumeis always exist this will happen In cooling operation unit switches to fan operation Unit will not restart after stop Won t start No outlet air or fan speed can t be changed in dry mode In heating operation water or steam are blown out of indoor NT unit r
7. right air direction Press the Left amp right button once the LCD aiflow direction will display as follows Remote controller E eton 1 Position 2 Position 3 Position 4 Position 5 Position 6 Position 7 Position 8 The left amp right flade will move according to the above conditions Note 1 During AUTO mode pls don t touch the flade to avoid damaging the inner part of the unit 2 f the difference between real position amp the chart position press ON OFF control panel button or ON OFF remote controller button to close the flade and re open the unit then it will be normal condition Operation Sleep Function Control panel ON OFF MODE FAN TEMP TEMP HEALTH ser E ar Use of SLEEP function Before using this function the clock must be set After the unit s start set running mode and then press SLEEP button once to make the air conditioner have the previous set sleep time first power on is 1h The sleep symbol will appear Press time button A v you can choose the time in 1 8 hours Each time the button is pressed the time increases decreases 1 hour xh and OFF indications appear on the display The control panel will display SLEEP ON LCD when SLEEP function set SLEEP RUN BEGINS SLEEP RUN STOPS Operation Mode GECKEN 1 In COOL DRY mode One hour after sleeping operation start the temperature is 1 C higher than the setting one After another hour t
8. supply Don t touch it with wet Don t wash with hot water hand or solvent to clean the unit DN A P Don t splash water directly on indoor Don t spray any paint or insecticide unit X on the unit This could be SS very dangerous LIL O4 Air filter cleaning Pull it out from top as shown in Fig Use water or vacuum cleaner to clean it If it is extremely dirty wash it with neutral CSE detergent or soap water pe 2 KI e Wash it with clean water and install it after SS complete dry Caution Don t use hot water over 40 C as this may cause damage to air filter Wipe air filter carefully 15 B Maintenance GENEE Indoor and outdoor cleaning Clean it with warm and wet cloth or with neutral detergent then wipe it dry with clean and soft cloth If air conditioner is very dirty clean it with cloth soaked in neutral detergent then wipe off the detergent with clean water Don t use water higher than 40 C which will cause discoloring and deformation Don t use insecticide or other chemical detergents After season maintenance Let the unit run in Fan mode for half a day ina fine weather to dry completely the unit inside Turn off the unit and pull out power plug There might be certain power consumption even if unit is stopped Clean air filter and indoor unit cover outdoor unit after cleaning Before season maintenance Check if there are
9. timer setting SLEEP Used to select sleep mode SET Used to confirm Timer and Clock setting LIGHT Control the light up and go out of the control panel s background light source and control the switch of the buzzer HEALTH Used to set Health operation function FAN Used to select fan speed AUTO LOW FAN MED FAN HIGH FAN SWING Used to set UP DOWN air sending and RIGHT LEFT air sending direction oo 6 Used to set temp temp range 16 C 30 C 5 Timer ON OFF display 9 Fan speed and air sending direction display Remote 4 a controller LOW HIGH AUTO mmm mm a a gj ma rv N 212 321234321234 4321234 LOW MID HIGH AUTO Part 1 to 4 bright periodically Control panel Swing direction display Room temperature display 9 Sleep state display Health display Display when set Health operation function Electric Heating display Fresh Air state display 3 Battery Capacity display Display when the electric power of the battery is insufficient Lock state display 65 Temperature display Used to display the set temperature and room temperature Clock display 6 Humidifying display 68 Power Soft operation display 69 HEAT Select Auxiliary electric heater Note These models don t have the following related display and function 62 68 For some air conditioners the function 69 is not availed For cooling only unit there is no funct
10. CABINET TYPE AIR CONDITIONER Operation amp Installation Manual AP482AKEAA AP602AKEAA No 0010578212 e Please read this operation manual before using the air conditioner e Please keep this manual carefully and safely Content Operation GONS E 1 2 PAIS cM 3 4 BEER 5 12 Operation hints ENEE 13 Energy Saving E 14 Maintenance m mMmMMmMMMeMeMeeel 15 16 Trouble SHOOTING 17 When problems occur 18 19 Indoor amp GUIGODI 20 I3 ANG AI 21 Installation procedures En 22 26 Others 55 27 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use please make sure it s inoperative and safe Unplug the air conditioner in order to avoid the risk of child entrapment It must be noticed that air conditioner system contains refrigerants which require specialized waste disposal The valuable materials contained in a air conditioner can be recycled Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting
11. HIGH Air conditioner will run at the selected fan speed 4 Unit stop Press ON OFF button to stop unit About FAN mode When the air conditioner runs in FAN mode it is not possible to select AUTO FAN or to set temperature Operation Air flow adjustment Swing louvers Vertical louvers Horizontal louvers Up and down Side from side Position1 Position 1 Position 2 Not availble in these units LL Position 2 D Position 3 Not availble in these units Position 3 ou Position 4 ka Position 4 PositionS COOL DRY FAN Position 5 AUTO COOL have not Position 6 Position 6 AUTO SWING S Position 7 N LI Position 8 AUTO SWING 2 Up amp down air direction Press the up amp down button once the LCD aiflow direction will display as follows Cooling Dehumification airflow Remote controller 95088 1 Position 2 Position 3 Position 4 Position 6J Heating essen 5 Position 4 Position 3 Position 2 Position 1 Position 6 7 Auto Baa 1 Position 2 Position 3 Position 4 Position 5 Position 6 7 The up amp down flade will move according to the above conditions Note Pay more attention to not cut down the power supply because the can t back to the colse position at this circumstance 22 3 Left amp
12. If there are unexpected heat in the room sources in the room Too many people in the room ee 72 If your unit still can t work properly after above mentioned checks or following problems occur please stop it immediately and contact your dealer Fuses or circuit breakers often blow out Water comes out in cooling dry operation Operation is abnormal or sound is heard If the fuse on PC board is broken please change it with the type of T3 15A 250VAC 18 When problems occur a eee 1 Errors display Failure description Code on LCD display discharge temp sensor abnormal The phase sequence of power abnormal or over current malfunction The communication between indoor PCB and control board abnormal The communication between indoor PCB and outdoor PCB abnormal E2 Outdoor high pressure or low pressure E6 abnormal 2 Power supply e Use copper wire only the parameter of connecting cable is HOSRN F 4G 0 75mm The power cable should be over HO7RN F 5G 2 5mm AP482AKEAA The power cable should be over HO7RN F 5G 4 0mm AP602AKEAA Air conditioner must use an exclusive line over 30A When installation air conditioner in a wet place try to use a circuit breaker against current leakage For installation in other places use circuit breaker as far as possible e The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3 mm
13. ct your desired operation mode operation mode will be displayed on LCD 2 TIMER mode selection Press TIMER button on the remote controller to change TIMER atti C mode Every time the button is pressed display of TIMER mode EN changes as follows MGD en EN PEN blank 12 00 12 00 12 00 12 00 TIMER ON TIMER OFF TIMER ON OFF Then select TIMER mode as needed TIMER ON or TIMER OFF C Now Kea will flash SLEEP 3 TIMER setting press time adjust buttons A Every time the button is pressed time increases 1 minuts If the button is kept pressed time changes quickly w Every time the button is pressed time decreases 1 minuts If the button is kept pressed time changes quickly It can be adjusted within 24 hours at will 4 Confirm setting After setting correct time press SET button to confirm time Now Eo stop flashing The control panel will display TIMER 5 Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears Hints a After replacing batteries or if a power failure occurs TIMER setting must be reset Remote controller has memory function When you use TIMER mode next time just press SET button after mode selection if timer setting is the same as the previous one P Note After setting TIMER function the remote controller displays TIMER time M 10 L Operation Timer ON OFF Funct
14. e might appear at outlet grill 3 min delay protection Unit will not restart until 3 min have elapsed for the protection of the unit Fan speed changes When Fan speed is set at Auto in cooling mode it will be automatically reduced as room temp is approaching temp setting In dry mode fan speed will change automatically Cold draft prevention In heating mode indoor fan will not run for the first 2 5 min due to cold draft prevention Defrosting When frost accumulates on heat exchanger in heating mode unit will start defrosting automatically During defrosting both indoor and outdoor fan stop After defrosting unit resumes running Use objectively Heat pump works by means of absorbing outside heat to warm room air so outdoor temp degree will affect unit s heating efficiency 13 Energy saving Keep proper room temp Too cold or too warm is no good to your health and power consumption will be increased as CT c well Air filter should be periodically cleaned If air filter is clogged It will cause poor cooling and heating efficiency higher power consumption and even problem may occur In cooling operation water will flow out Use Timer effectively ON OFF You may use Timer mode to keep 8 00 5 00 a comfortable room temp when you wake up or come home from outside Avoid direct sunlight Adjust air flow and air flow properly Maintenance Disconnect power
15. emperature rises 1 sleep run continuously SETTING T SHUT DOWN for another 6 hours and then stops The actual temperature is higher than the setting one which In COOL DRY mode is to prevent from being too cold to your sleep 2 In HEAT mode One hour after sleeping operation start the SETTING T SHUT DOWN temperature is 2 C lower than the setting one After another hour temperature decreases by 2 C more Temperature will automatically rise by 1 after another 3 hours continuous operation The actual temperature is lower than the setting one which is to prevent from being too hot to your sleep SLEEP RUN BEGINS SLEEP RUN STOPS 3 In AUTO mode In HEAT mode The air conditioner will run in corresponding sleep operation according to the automatically selected operation mode Remote controller TEM lh aul fh M Er Do Notes e After setting SLEEP function it is not possible to set clock Ze f set sleep time does not reach 8 hours unit will automatically stop operation after set time is reached e Set TIMER TIMER OFF In COOL DRY mode function first then set SLEEP After set SLEEP function the TIMER function cannot be set Operation Timer ON OFF Function Manual Operation Control panel Set clock correctly before starting TIMER operation Remote controller 1 Unit start After unit start sele
16. er vacuumizing fasten the repair valve and dismount the cap of the big and small stop valve then loosen the stop valve center completely and fasten the big and small stop valve 25 Installation procedures Electric wiring OA EN ee Note Electric wiring must be done by qualified person The power supply connects from the outdoor unit The connecting cable and power cable are self provided Wiring of indoor unit Insert the cable from outside the wall hole where piping already exist Pull it out from front e Loosen terminal screws and insert cable end fully into terminal block then tighten it Pull the cable gently to make sure it is tight e Replace cover after wiring eee FIFA Wiring of outdoor unit og ss l Insert the cable from inside the wall hole E S s ll in where piping already exists N TTT ut Pull it out from front e Loose terminal screw and insert cable end fully into terminal block then tighten it Pull the cable gently to make sure it is tight Replace cover after wiring AP482AKEAA AP602AKEAA Y G POWER SUPPLY 380 400V 3N 50Hz m When connecting indoor and outdoor wire check the number on indoor and outdoor terminal blocks Incorrect wiring may damage air conditioner s controller or cause
17. ion Manual Operation Control panel Remote controller Set clock correctly before starting TIMER operation 1 Unit start After unit start select your desired operation mode operation mode will be displayed on LCD 2 TIMER mode selection Press TIMER button on the remote controller to change TIMER mode Every time the button is pressed display of TIMER mode changes as follows EIN KEN blank Au 12 00 eu12 00 444200 12 00 TIMER ON TIMER OFF TIMER ON OFF MODE Then select TIMER ON OFF mode will flash 3 Time setting for TIMER ON Press time button A Every time the button is pressed time increases 10 minuts If the button is kept pressed time will changes quickly SLEEP V Every time the button is pressed time decreases 10 minuts If the button is kept pressed time will changes quickly It can be adjusted within 24 hours at will AM refers to morning and PM refers to afternoon 4 Timer confirming for TIMER ON After setting correct time press TIMER button to confirm time Now 8 stops to flash while 39 starts flashing 5 Timer setting for TIMER OFF Press time buttons Ge and follow the same procedures in Time setting for TIMER 6 Time confirming for TIMER OFF After time setting press SET button to confirm time 99 stops to flash The control panel will display TIMER 7 Canel TIMER mode Just press TIMER button several times until TIMER
18. ions related to heat Operation Clock set When unit is started for the first time and after replacing batteries in remote controller clock should be adjusted as follows Press CLOCK button PM flashes Press set correct time Each press will increase or decrease 1 min If the button is kept pressed time will change quickly After time setting is confirmed press SET AM and PM stop flashing while clock starts working Remote controller s operation When in use put the signal transmission head directly to the receiver hole on the indoor unit The distance between the signal transmission head and the receiver hole should be within 7m without any obsacles as well Don t throw the controller prevent it from being damaged When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signal so the distance to the indoor unit should be shorter Loading of the battery Slightly press w and push down the cover Load the batteries as illustrated 2 R 03 dry batteries cylinder Be sure that the loading is in line with the pole request as illustrated N Ge Put on the cover again NS Confirmation indicator 2R 03 dry batteries In disorderation reload the batteries or load the new batteries after 5 mins
19. king a wall hole Drill a hole of 70mm dia with a little slope towards outside Install piping hole cover and seal it with putty after installation INDOOR SIDE OUTDOOR SIDE wall hole wall thickness 4429 Cross section of wall hole 70mm Fixing of indoor unit With the unit set up vertically fix the fitting metal to the unit with screws then fix the fitting metal to the wall with cement nail and washer as shown below 1 Cement nail E 1 Fitting metal hete hole KET E L Screw Moreover if want to fix the unit more firmly you should fix the bottom panel to the ground with concrete bolts as shown below 79 202 202 79 Installation procedures Piping connection 1 Connecting method Apply refrigerant oil at half union and flare nut To bend a pipe give the roundness as large as possible not to crash the pipe When connecting pipe hold the pipe centre to centre then screw nut on by hand refer to Fig Be careful not to let sundries such as sands enter the pipe Forced fastening without centering may damage the threads and cause a gas leakage Pipe dia Fastening torque Liquid pipe 9 52mm 3 8 32 7 39 9N m ES 1 Gas pipe 19 05mm 3 4 97 2 118 6N m 2 Piping connection of indoor unit Arrangement of piping and drainage pipe After opening inlet grill you will see a control box as shown in the Fig Remove the cover before wiring work
20. mode disappears According to the time setting sequence of TIMER ON and TIMER OFF either start stops or stops start can be realized If the time setting of TIMER ON is the same as TIMER OFF TIMER ON OFF function cannot be set 11 Operation Control panel display as Control panel ON OFF MODE FAN Display function 1 Control panel display control Press the LIGHT button the LCD will display according to the following sequence when press once LCD bright LCD bright LCD not bright Buzzer not Buzzeract Buzzer act 2 LCD color control Auto White amp Pink a KA Green 1 Cooling Blue Negativeion amp Green Anti bacterial Heating amp Auxillary ro lt Double fresh air Dehuimidy Light blue When the LCD bright the color will display according to the above standard color when two or more than two kinds of functions operate the color will display according the priority class Sequence from High to low 3 2 1 When cut off the power and restart the power the room temp will be displayed after full screen display lasting 5 seconds Press the panel button or remote control the air conditioner will send out music sound 12 Operation hints Unit operation Protection devices inside the unit will activate to stop unit operation when ambient temp is extremely low or high When unit is running under high humidity in cooling or dehumidifying mode condensat
21. ng up Note When delivering don t hold plastic PA Facing up parts like inlet and outlet grill etc Installation of outdoor unit Selection of installation place E Place strong enough to support the unit and will en not cause vibration and noise C Place where discharged wind and noise doesn t cause a nuisance to the neighbors Place where is less affected by rain or direct sunlight and is sufficiently ventilated or to install over 10cm a shield O Place with enough space for smooth air flow over 60cm E Fixing of the unit Fix outdoor unit using M10 bolt to concrete floor horizontally O If installed on the wall or on top of a roof bracket should be fixed securely to resist earthquake or storms O Use rubber pad during installation against unit vibration Installation dimension of outdoor unit mm 22 Installation procedures ns Installation of indoor unit Selection of installation place Place where it is easy to route drainage pipe and outdoor piping Place away from heat source and with less direct sunlight Place where cool and warm air could be delivered evenly to every corner of the room Place near power supply socket Leave enough space around the unit refer to installation drawings Fixing of the unit 1 Position of the wall hole Wall hole should be decided according to installtion place and piping direction refer to installation drawings 2 Ma
22. nge it with the type of T 3 15A 250VAC Please check the circuit diagram about the fuse replaced 4 The wiring method should be in line with the local wiring standard 5 The power cable and connecting cable are self provided All the cables shall have got the local authentication certificate 6 The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less 3mm Such means for disconnection must be incorporation in the fixed wiring 7 The waste battery shall be disposed properly B Parts HEALTH ogen 585 egpgpo P 1 Outlet grill 2 Operation panel 3 Inlet grill 4 Air filter inside the unit NES EN Remote controller P d Outdoor unit 1 Inlet grill 2 Outlet grill Manual Operation OO O GOO eo Parts ON OFF FAN TEMP TEMP HEALTH MBE HD Power ON OFF Used for unit start and stop MODE Used to select AUTO run COOL DRY FAN and HEAT operation CLOCK Used to set correct time Used to select TIMER ON TIMER OFF TIMER ON OFF 9 LOCK Used to lock buttons and LCD display RESET Used to reset the controller back to normal condition HOUR Used to set clock and
23. operation failure 26 Others 1 Pipe cutting and flaring Be sure to carry out deburring after pipe cutting with a pipe cutter Insert flaring tool to make a flare Incorrect Lean H flare Crack En H duse Liquid pipel 9 52mm 3 8 0 7 1 7 Gas pipe 219 05mm 3 4 2 Installation inspection and test run Please operate unit according to this Manual Items to be checked during test run Please made a 7 in there any gas leakage L1How is insulation at piping connection carried out electric wires of indoor and outdoor unit firmly inserted into terminal block O Is electric wiring of indoor and outdoor securely fixed Os draminage securely carried out O ls earth line grounding securely connected CG Is power supply voltage abided by the code O ls there any noise O Is control display normal 015 cooling operation normal O Is room temp regulator normal 27 HAIER GROUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com
24. r the purpose of safety the air conditioner must be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Cautions e All electrical repairs must be carried out by qualified electricians Inadequate repairs may result in a major source of danger for the user of the air conditoiner Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner s tubes with sharp or pointed items crushing or twisting any tubes or scraping the coatings off the surfaces If the refrigerant spurts out and gets into eyes it may result in serious eye injuries Do not obstruct or cover the ventilation grille of the air conditioner Do not put fingers or any other things into the inlet outlet and swing louver e Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit Specifications e The refrigerating circuit is leak proof The machine is adaptive in following situation 1 pplicable ambient temperature range SSS ted Maxime Minimum 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person 3 If the fuse on PC board is broken please cha
25. stops running In DRY mode when room temp becomes 2 C OD Press ON OFF button higher than temp setting unit will run intermittently Unit starts running at LOW speed regardless of FAN setting The previous status appears on the display eae starts when m temp is higher than temp setting except TIMER SLEEP mode Ultra low air flow Temp setting 2 C Press MODE button For each press Temp seing V On reaching 2 C higher than temp operation mode changes as follows setting unit will run in mild DRY mode Note During Auto run operation temp setting will be shown in LCD display unit will select heating cooling or fan operation according to the room temp Operation Fan Operation Manual Operation Control panel ON OFF MODE FAN TEMP TEMP HEALTH Remote controller 1 Unit start Press ON OFF button to start your air conditioner Previous operation status appears on LCD except for TIMER SLEEP setting 2 Select operating mode Press MODE button At each press operation mode changes as follows TN v Km A gt 3t emote nolla AUTO COOL DRY FAN HEAT CH m 4 eis 3t Control panel AUTO COOL DRY FAN HEAT Then select FAN 3 Adjust fan speed Press FAN button At each press fan speed changes as follows is BH Remote ll H TI controller LOW MED HIGH C nir l men LOW MID