GE 3200 Heat Pump User Manual

image

Contents

1. For personal safety this Zoneline must be prop erly grounded Aluminum building wiring may present special a roblems consult a qualified electrician Protective devices fuses or circuit breakers p q acceptable for Zoneline installations are speci When the unitis in the STOP position there is still fied on the nameplate of each unit voltage to the electrical controls Disconnect the power to the unit before servicing by 1 Removing the power cord if it has one from the wall receptacle or 2 Removing the branch circuit fuses or turning the circuit breakers off at the panel Zoneline Components YOU WILL NEED Phillips screwdriver Exterior grille louver Wall case Zoneline unit Room cabinet Shipped with the Zoneline unit Check the Essential Elements list on the unit 11 Installation Instructions How to Connect I Remove the room cabinet 3 See the special instructions below for 2 Connect to electrical power applicable supply voltages 4 Reinstall the room cabinet 230 208 Volt Electrical Supply All wiring including installation of the receptacle must be in accordance with the NEC and local codes ordinances and regulations This unit is equipped with a line cord for appropriate amperage wall receptacle See below Tandem Perpendicular Large Tandem 15 Amp 20 Amp 30 Amp Electrical wiring wall outlets 230 208 volts 12 Q 265 Volt Electrical Supply A
2. Zoneline Series Heat Pump M odel 3200 Heat Cool M odel 2200 Zoneline Owner s M anual Important Safety Information Operating Instructions The Controls on Your Zoneline Care of Product gt Installation Instructions Important Electrical Safety Adjustments and Auxiliary Controls Helpful Information Things That Are Normal If Something Goes Wrong Before You Call For Service GE Service Numbers Warranty GE Answer Center 800 626 2000 GE Appliances 49 7359 Before using your Zoneline Need Help Help us help you 500 626 2000 Welcome to the GE family We re proud of our quality products and we believe in dependable service You Il see it in this easy to use manual and you ll hear it in the friendly voices of our customer service department Staple your receipt to the inside back cover of this manual You will need it to obtain service under warranty Before you call for service there are a few things you can do to help us serve you better Read this manual It contains instructions to help you use and maintain your Zoneline properly Save time and money Check the section titled If Something Goes Wrong before calling This section was designed to solve common problems that might occur Best of all you ll experience these values each time you enjoy the comfort of your Zoneline That s important because your new Zoneline will be part of your fa
3. Electric will provide free of charge parts that fail as a result of a manufac turing defect Parts covered are fan motors switches thermostat heater heater protectors compressor over load solenoids circuit boards auxiliary controls thermistors Freeze Sentinel frost controls ICR pump capacitors varistors and indoor blower bearing This is a limited parts only warranty and does not include labor or trans portation to and from the service shop Failure or damage resulting from corrosion due to installation in an environment containing corrosive chemicals Failure or damage resulting from corrosion due to installation ina coastal environment except for models treated with special factory applied anti corrosion protection as designated in the model number Damage to product caused by improper power supply voltage acci dent fire floods or acts of God Incidental or consequential damage to personal property caused by possi ble defects with this air conditioner Warrantor General Electric Company Louisville KY 40225 This warranty is extended to the original purchaser and any succeeding owner for products purchased for use within the USA and Canada In Alaska the warranty excludes the cost of shipping or service calls to your site Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other
4. know your air conditioner inside and 800 432 2737 convenient for you out so most repairs can be handled in just one visit Parts and Accessories o Individuals qualified to service Care and cleaning instructions con 800 626 2002 their own air conditioner can have tained in this manual cover proce parts or accessories sent directly dures to be performed by any user to their home Other servicing generally should be VISA MasterCard and Discover referred to qualified service person cards are accepted nel Caution must be exercised since improper servicing may cause unsafe operation Further Service Service a First contact the people who ser Finally if your problem is still If for some reason you viced your air conditioner Explain not resolved write are not happy with the why you are not pleased Major Appliance service you receive here Next if you are still not pleased Consumer Action Program are three steps to follow write all the details including 20 North Wacker Drive for further help your phone number to Chicago IL 60606 Consumer Relations GE Appliances Louisville KY 40225 3 ZONELINE WARRANTY What Is Covered What Is Not Covered Staple sales slip or cancelled check here Proof of original purchase date is needed to obtain service under warranty All warranty service will be provided by our Factory Service Centers or an authorized Customer Care technician FUL
5. Causes The unit is unplugged The fuse is blown circuit breaker is tripped The unit is waiting for the compressor overload protector to reset Power failure Indoor airflow is restricted Outdoor airflow is restricted or recirculated The temp control may not be set high or low enough The air filter is dirty The room may have been hot or cold Outdoor air is entering the room If Something Goes Wrong before You Call For Service What to Do Make sure the Zoneline plug is pushed completely into the outlet Check the house fuse circuit breaker box and replace fuse or reset the breaker This is normal The Zoneline will start again after it resets If power failure occurs set the mode control to STOP When power is restored set the mode control to the desired setting There is a protective time delay up to 3 minutes to prevent tripping of the compressor overload For this reason the unit may not start normal heating or cooling for 3 minutes after it is turned back on Make sure there are no curtains blinds or furniture blocking the front of the Zoneline Make sure the rear grille is not restricted This can cause the unit to cycle off due to the compressor overload Turn the control to a lower or higher setting NOTE The temperature limiter may be limiting the temperature range Clean the filter at least every 30 days When the Zoneline is first turned on you need to allow time for th
6. L ONE YEAR WARRANTY For one year from date of original pur chase we will provide free of charge parts and service labor on site to repair or replace any part of the Zoneline that fails because of a manufacturing defect FULL FIVE YEAR WARRANTY For five years from the date of original purchase we will provide free of charge parts and on site service labor to repair or replace any part of the sealed refrigerating system the compressor con denser evaporator and all connecting tubing that fails because of a manufac turing defect Service trips to your site to teach you how to use the product Improper installation If you have an installation problem or if the air conditioner is of improper cooling capacity for the intended use contact your dealer or installer You are responsible for providing adequate electrical connecting facilities Replacement of fuses or resetting of circuit breakers In commercial locations labor neces sary to move the unit to a location where it is accessible for service by an individual technician Failure of the product resulting from modifications to the product or due to unreasonable use including failure to provide reasonable and necessary maintenance For service in the U S call SOO GE CARES For service in Canada call 1 800 361 3400 LIMITED 2ND THROUGH 5TH YEAR PARTS WARRANTY For the second through the fifth year from date of original purchase General
7. Switch The fan switch 2 is located behind If you want the fan to cycle on the room cabinet and off with the compressor or Freeze Sentinel CDC Load Shedding All Time Low Fan This switch is set at continuous fan with the heater move the switch DOWN at the factory to provide to cycle fan UP continuous fan operation in cool or heat modes Leaving the switch in the continuous fan setting allows continuous circulation of room air Auxiliary Controls and will result in a more balanced temperature throughout the room Down Continuous Fan Up Cycle Fan Freeze Sentinel Sentinel Switch 6 controls the Freeze The Freeze Sentinel helps prevent Sentinel When the switchis DOWN plumbing damage in the room due the Freeze Sentinel automatically to sub freezing temperatures turns on the resistance heater and If the Freeze Sentinel is set it is fan if the room temperature sensed active as long as power to the at the unit drops to approximately unit is on 40 F It will turn the heater off when NOTE The owner is responsible for the temperature reaches about 45 F p checking the Freeze Sentinel switch The unit leaves the factory with and ensuring itis in the desired the Freeze Sentinel in the DOWN setting 7 on position Operating Instructions Care amp Cleaning Room Cabinet and Case Turn the Zoneline off and discon To clean use water and a mild nect the power supply deter
8. WARNING Connection of this 205V product to a branch circuit MUST be done by direct connection to be in compliance with the National Electric Code Plugging of this unit directly into a building mounted exposed receptacle is not permitted by code These models must be installed using one of the following methods A Electrical subbase kits are available to provide a flexible enclosure for direct connection Branch Circuit and Chassis Proper GE Amperage Rating Subbase Kit 15 RAK204E15 20 RAK204E20 30 RAK204E30 The instructions provided with the selected subbase kit must be carefully followed It is the responsibility of the installer to ensure that connection of components is done in accordance with these instructions and all electrical codes B For direct connection to branch circuit wiring inside the provided junction box without using a subbase kit the cord is to be cut and the wire ends stripped and connected as follows Steps for preparing cordset for direct connection 1 Remove the junction box cover by taking out the front four screws 2 Remove the junction box by taking out the top rear screw Note how the tab at the lower right corner of the junction box serves to hold the corner in place This will help when the box is being reinstalled The cord will be coiled up inside the junction box Tab on chassis Strain J unction relief box cover 0 oa es o Slot in juncti
9. and off to keep the room at the same level of comfort When you turn the knob to COOLER blue the indoor air will become cooler Turn the knob to WARMER red and the indoor air LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating NOTE If you move the switch from a cool or heat setting to STOP or to a fan setting the unit has an automatic 3 minute delay before allowing the compressor to restart in the cool or heat mode will become warmer 3200 Series only When the outdoor temperature is lower than 25 F heat is provided by the electric heater in the air conditioner instead of by the heat pump Energy Tip G Keep the vent control at CLOSE The room air will be filtered and circulated Louver screws Louver screws Remove the room cabinet and flip the louvers to change the air direction Vent control A A Air Direction A Ventilation Control The ventilation control lever is located at the To adjust the air direction remove the room lower left side of the Zoneline unit behind the cabinet Remove the 7 louver screws that room cabinet hold the louvers in place Flip the louver When set at CLOSE only the air inside the room section 180 replace the screws and the is circulated and filtered room cabinet When set at OPEN some outdoor air will be drawn into the room This will reduce the heating or cooling efficiency Operating Instructions Oth
10. e room to cool down or warm up Set the vent control to the CLOSE position 2 If Something Goes Wrong Before You Call For Service Problem Burning Odor at the Start of Heating Operation The Airis Not Always Cool or Hot During Operation The Air Does Not Feel Warm Enough During Heating Operation Possible Causes Dust is on the surface of the heating element The heat pump is not producing hot air The fan switch may be set at continuous fan down The heat pump alone produces air that feels cooler than desired What to Do This can cause a burning odor at the beginning of the heating operation This odor should quickly fade This is normal The heat pump will produce warm air but not as hot as air produced when the higher cost electric heat is used This causes the fan to blow room temperature air even when the compressor or heater cycles off The continuous air movement provides better overall temperature control Use the Electric Heat Option This turns off the heat pump and warms with electric heat only NOTE Use of this option will result in increased energy consumption 21 Notes 22 GE Service Numbers We ll be there GE Answer Center Open 24 hours a day 800 626 2000 7 days a week TDD 800 833 4322 On Site Repair Service We provide expert repair service Our factory trained technicians 800 GE CARES scheduled at a time that s
11. ed up and thrown against the condenser on rainy days or eee when the humidity is high This design feature helps remove moisture and improve efficiency a C LI C K You may hear relays click when the controls cycle on and off or are adjusted to change the room temperature Water will collect in the base pan during high humidity or on rainy O days The water may overflow and drip from the outdoor side of the unit The indoor fan runs continuously when the unit is operating in the cooling mode unless the fan switch behind the room cabinet is set I fe at fan cycle up This will cause the fan to cycle on and off with the compressor You may also hear a fan noise stop and start xe You may notice a few minutes delay in starting if you try to restart the wi Zoneline too soon after turning it off or if you adjust the thermostat gt a8 right after the compressor has shut off This is due to a built in restart protector for the compressor that causes a 3 minute delay The compressor shuts off during the defrost cycle Full resistance S LE N heat comes on during the defrost cycle to maintain room comfort To protect the compressor and prevent short cycling the unit is COMPRESSOR p p p ycling PROTECT designed to run for a minimum of 3 minutes after the compressor starts at any thermostat setting 19 Problem Zoneline Doesn t Start Zoneline Does Not Cool or Heat as it Should 20 Possible
12. er Zoneline features About Your Heat Pump 3200 Series only To Remove the Room Cabinet Heat pumps can save money by removing heat from the outside air even when the outside temperature is below freezing and releasing that heat indoors To get the best performance from your heat pump don t change the room thermostat very often Raising the heat setting 2 3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly Additional controls are located behind the room cabinet To remove Pull out at the bottom to release it from the tabs Then lift up There is a three minute minimum compressor run time at any setting to prevent short cycling The indoor fan motor starts before the compressor and stops after the compressor cycles off The electric heating elements use much more electricity than heat pumps and cost more to operate To replace Place the tabs over the top rail Push inward at the bottom until it snaps into place Auxiliary Controls uxiliary Controls B The auxiliary controls are located behind the room cabinet on the front of the unit control box The factory settings will be in the DOWN position The owner is responsible for checking switches and ensuring they are in the desired position AIl Electric Heat UP Fan cycle DOWN Fan continuous Remote Control Class 2 Not on Model 2200 Series Fan
13. filters Vacuum off the heavy soil Run water through the filters Dry thoroughly before replacing A CAUTION DO NOT operate the Zoneline without the filters in place If a filter becomes torn or damaged it should be replaced immediately and airflow Operating without the filters in place or with damaged filters will Clogged filter Greatly reduces cooling heating allow dirt and dust to reach the in door coil and reduce the cooling heating airflow and efficiency of the unit Replacement filters are available from your salesperson GE dealer GE Service and Parts Center or authorized Customer Care servicers Installation Instructions Check the Essential Elements label for important information Use the correct wall case This chassis is designed to be installed in a GE plastic or insulated metal wall case This mini mizes condensation from forming on the room side of the case If the current wall case is not insulated you can reduce the possibility of condensation forming by installing insulation kit RAK9OIL available where you purchased the chassis Use the correct outdoor grille You should use the outdoor grilles shown on the Essential Elements label on the top of the chassis If an existing grille is not replaced capacity and efficiency will be reduced and the unit may fail to operate properly or fail prematurely A deflector ki
14. gent Do not use bleach or abrasives Some commercial cleaners may damage the plastic parts Outdoor Coils Coils The coils on the outdoor side of ae the Zoneline should be checked regularly If they are clogged with AAN AM AK AK AN AN AN Ai dirt or soot they may be profes sionally steam cleaned a service p available through your GE service outlet You will need to remove the chassis to inspect the coils because the dirt build up occurs on the inside Clean the outside coils regularly BasePan ase Pan Eas In some installations dirt or other Check it periodically and clean it debris may be blown into the unit out if necessary from the outside and settle in the base pan the bottom of the unit In some areas of the United States a jell like substance may be seen in the base pan AirFilters O Turn the Zoneline off before cleaning To remove the air filters The most important thing you can Operating Tip do to maintain the Zoneline is to To maintain optimum clean the filter at least every 30 performance clean days Clogged filters reduce cool the filters at least ing heating and air flow every 30 days Keeping these filters clean will Decrease cost of operation Save energy Prevent clogged heat exchanger coils 14 VG i4 We 2 ieee ee Reduce the risk of premature component failure To clean the air
15. h those kits Stiffener 3 Install the exterior grille from the room side following instructions packed with the grille Remove the Shipping Tape from the Room Cabinet 1 Carefully remove shipping tape if there is any 2 Remove the room cabinet by pulling it out at from the room cabinet and vent door the bottom to release it then lift it up to clear the rail along the unit top Shipping tape 15 Installation Instructions Install the Unit into the Wall Case Slide the unit into the wall case and secure with four screws through the unit flange holes If an insulated wall case is needed see Install the Wall Case and Exterior Grille section on the previous page Replace the Room Cabinet Reinstall the room cabinet by hooking the top over the rail along the unit top then pushing it in at the bottom 16 Low Voltage Connectors amp Auxiliary Controls gQ NOTE The owner is responsible for checking all switches and ensuring they are set in the desired setting Electric Heat Option Model 3200 Series only The Electric Heat Option switch 1 increases To set the Electric Heat Option move switch to the Zoneline air temperature by using electric the ON up position heat only The heat pump is not used to produce any heat Using the Electric Heat Option is much more expensive than heating with the heat pump only Auxiliary controls Temperature Limiting Temperature limiting can reduce energy cost
16. mily for a long time Write down the model and serial numbers here They are on a label behind the room cabinet on the base pan Model number Serial number Date of purchase If you do need service you can relax knowing help is only a phone call away Toll free customer service numbers are included in the back of this manual Or call the GE Answer Center at 800 626 2000 24 hours a day 7 days a week IMPORTANT SAFETY INFORMATION READ ALL SAFETY INFORMATION BEFORE USING This Zoneline must be properly Unplug or disconnect the installed in accordance with the Zoneline at the fuse box or Installation Instructions before it circuit breaker before making is used See pages 10 12 any repairs Repair or replace immediately NOTE We strongly recommend all electric service cords that have that any servicing be performed become frayed or otherwise by a qualified individual damaged SAVE THESE INSTRUCTIONS Replacing an For details see the Installation Instructions in the back of this manual existing unit Operating Instructions TEMP CONTROLS MODE CONTROLS The LOW controls STOP o on your HEAT CooL Zoneline HEAT CoOL A A Temp Control A M ode Control The temp control is used to maintain the HIGH COOL and LOW COOL provide cooling with room temperature The compressor will cycle different fan speeds HIGH HEAT and LOW HEAT provide heating with different fan speeds on
17. on box 3 Measure 6 down the cord from the strain 7 J unction box relief securing the cord to the chassis and cut the cord through at this point 4 Carefully split the cord insulation at the center for 2 so as to separate into three insulated wires Be careful not to cut through the center green ground wire insulation 5 Strip 3 4 of the insulation away at the end of each of the three wires L1 Neutral and Ground The Neutral wire is identified by molded rib along its entire length The L1 Hot wire insulation is smooth Neutral wire 3 4 Strain molded rib relief e 7 Ground wire L1 wire Smooth Installation Instructions 6 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit Remove the knockout attach the conduit and bring wires into the junction box Leave 6 of wire free at the end of the conduit to allow connections to be made 7 Ifa fuse and fuseholder are to be used the knockout at the top of the box is for mounting a Buss Fuseholder Be sure the fuse and fuseholder are of the same rating as the branch circuit Leadwires at the fuse can be either soldered in place or attached using UL listed 1 4 female receptacle crimp connectors 14 8 Reinstall the junction box by engaging the tab at the lower rear aligning the screw hole at the top and driving the one screw until secure Be sure that all wire leads a
18. re inside the box and not pinched between the box and the chassis The identified ribbed Neutral wire of the cordset MUST be connected to the white Neutral wire of the branch circuit The green insulated ground wire from the chassis MUST be connected to the branch circuit ground wire Make all wire connections by using appropriate UL listed electrical connectors and techniques black to black white to white and green to green 10 Carefully tuck all wires and connections back inside the junction box Be sure there are no loose connections or stray uninsulated wires exposed 11 Place the junction box cover in place Replace the four screws removed earlier and tighten securely 12 Discard the unused portion of the plug and the cordset Q Install the Wall Case and the Exterior Grille 1 The RAB71 or RAB77 wall case must be Insulated Wall Case properly installed per instructions packed This chassis is designed to be installed in a with the case GE plastic or an insulated steel wall case This gt Remove the corrugated stilenerand the minimizes condensation from forming on the outdoor protective panel Use the slit in the room side of the case outdoor panel as a handhold and push out The RAB71 wall case is insulated Insulation kit POP T RAK9O1L is available for use with RAB77 or panel existing uninsulated wall cases when needed NOTE For installation with a subbase or duct adapter see the instructions packed wit
19. rights which vary from state to state To know what your legal rights are in your state consult your local or state consumer affairs office or your state s Attorney General Pub No 49 7359 12 97 CG Printed in China Zoneline 2200 3200 Series
20. s by limiting the lowest temperature that can be set B for cooling and the highest temperature that can S be set for heating Limiting the maximum and minimum settings prevents users from turning the control to the extreme heat or cool positions The normal full range of the temp control is E E approximately 62 F to 85 F The control range ee H a may be narrowed by the use of the temperature temp temp limiting screws located behind the control panel Each position equals approximately 3 F 17 Installation Instructions Remote Control Wall Thermostat Class 2 To operate the Remote Control Wall Thermostat Class 2 switch 3 you must use an Optional Interface Module kit See the Installation Instructions with accessory kit RAKOIM Auxiliary Controls Central Desk Control Load Shedding To operate Central Desk Control CDC switch 5 you must have an Optional Interface Module kit See the Installation Instructions with accessory kit RAKOIM All Time Low Fan Switch 4 controls the All Time Low Fan and is only effective with a Remote Control Thermostat This function causes the indoor fan to operate at low speed If the switch is DOWN off the fan will run in high speed If the switch is UP on the fan will run in low speed 18 Helpful Information Things That Are Normal Noise OEE You may hear a pinging or popping noise caused by water being pi N G L POP pick
21. t RAK40 may be used with grilles that were not designed for your new GE Zonelines The RAK40 contains air deflectors and gaskets that mount to the chassis to direct the hot exhaust air away from the air intake to allow the unit to function properly The grille must have a 65 minimum free area 10 Read carefully If you have any questions call the GE Answer Center at 800 626 2000 Any vertical deflectors in the existing rear grille should be removed to decrease condenser air recirculation which can cause the unit to short cycle and lead to premature compo nent failure Replacing a ducted chassis New ducted installation If this unit is to be installed in a new ducted application using a duct adaptor kit the kit must be installed before the chassis is placed in the wall case The installa tion instructions are packed with the kit M ounting plate Existing ducted installation Replacement of an existing ducted unit may require different com ponents Request this information from your sales representative Replacing 230 208 volt units See page 12 Replacing 265 volt units See page 13 Important Electrical Safety Read Carefully Q Installer Leave these instructions with the Zoneline Owner Keep these instructions for future use Important Notes Follow the National Electrical Code NEC or local codes and ordinances A CAUTION Do not use an extension cord with this unit

Download Pdf Manuals

image

Related Search

Related Contents

Samsung C103 Specifications  Wilo-Control IF-Module LON / Stratos LON  可変抵抗減衰器 AT-50 - 日本テクニカル・サービス  der Bedienungsanleitung  Bottom-Mount Refrigerator Refrigerador con congelador L_ en la  PEGASUS - bartec  MANUEL d`UTILISATION  Sony DDU1632 User's Manual  平成26年度 「介護予防支援従事者研修」募集要領  Whirlpool WFW8300S User's Manual  