GE 1018959 Network Card User Manual

image

Contents

1. If any problems are encountered with the installation procedure here described please contact the nearest Service Centre before proceeding 3 1 3 PH SNMP WEB PLUG IN ADAPTER P N 1018959 NOTE SitePro customers only SitePro units produced before 2003 require an additional protective ground connection refer to APPENDIX A 3 1 1 Setting the logical address The logical address is configured through dip switch SW1 in the following way Logical Address Dip 1 Dip 2 SNMP Card 0 1 84 54h ON ON SNMP Card 1 85 55h ON OFF SNMP Card 2 86 56h OFF ON SNMP Card 3 87 57h OFF OFF 1 Default setup Dip switch SW1 NOTE The logical address is a critical setting when more than one SNMP Card is installed in the same UPS system Modifications reserved Page 14 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 3 1 2 Installing the SNMP Card in option slot IMPORTANT Switch off the UPS and wait approx 2 minutes or switch the UPS to the manual bypass In the latter case please ensure that the mains input is reliable during this period All cables must be disconnected from the card during the installation Install procedure for LANPRO 33 LP 33 Series Option slot see description below for procedure Customer interface 1 Remove the plate that covers the Option slot by cutting the edges which are holding the plate T
2. 1 1 WARNINGS AND CAUTIONS GENERAL e Always strictly observe the UPS Safety Rules e Check carefully the integrity of the equipment In case you note some visible damage do not install the equipment but contact the nearest Service Centre e WARNING RISK OF ELECTRICAL SHOCK Do not remove any UPS covers there are no user serviceable parts inside e After switching off it takes up to 5 minutes for the DC capacitors to discharge because a lethally high voltage remains at the terminals of the electrolytic capacitors e All maintenance and service work should be performed by qualified service personnel e The outlet bars may be electrically live even when the UPS is disconnected from the mains STORAGE e Store the SNMP Web adapters in a dry location storage temperature must be within 25 C to 55 C 13 F to 131 HANDLING e The SNMP Web adapters are ESD sensitive devices When handling the adapters only touch the front panel external cover and use suitable ESD protection e g wrist straps e The SNMP Web adapters contain a removable lithium coin cell battery Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate INSTALLATION e Switching OFF the unit does not isolate the UPS from the mains e Do not install the equipment in an excessively humid environment or near water e Avoid spilling liquids on or dropping any foreign object onto the equipment e The equipmen
3. 1018959 SP SNMP Web plug in adapter P N 23954 These devices have been tested for compliance with the following standards e EN 61000 6 2 e EN 61000 6 4 WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications reserved Page 8 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 2 INTRODUCTION 2 1 CHECKING PACKAGE CONTENTS The SNMP Web adapters are delivered in different kits according to the model 3 ph SNMP Web plug in adapter P N 1018959 e 3 ph SNMP Web plug in adapter with pre installed standard front panel e A front panel designed for LP33 Series UPSs e Square plates for older SitePro UPSs e Mounting screws e Installation
4. e Connect the UPS to the SNMP WEB Interface box Sub D connector UPS using the cable provided with the UPS VIC 23 or IMV I or 1 1 straight cable for intelligent communication Note when using the Contact Interface communication on GE Digital Energy UPS a VIC 25 or IMV C cable kit is required Modifications reserved Page 17 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter e Connect the power to the box left most connector in the picture above Make sure that the SNMP WEB Interface box is powered by the UPS output e The UPS Fail LED will switch OFF once the connection to the UPS is established If the LED remains continuously on check the UPS connection and related cabling 3 5 INTERFACES UTP 10 100 RJ45 port Connection to an Ethernet 10 100 Mbits s networks using an UTP cable RS 232 DB9 port Serial communication connection to a local console Use a straigth 1 1 serial cable for connection to a PC Connector pin out as follows Pin Function 2 TD Transmit Data 3 RD Receive Data 5 GND Contact interface RJ11 port 1 ph plug in version only Plug in contact interface port Connector pin out as follows Pin Function 1 Mains failure 2 General alarm 3 Battery low 4 On bypass 5 N C 6 GND Active if the output voltage of the UPS is no longer guaranteed due to other circumstances than already indicated by pin 1 3 4 CAUTION
5. following features 10 100 Mpbs connection speed Use of DHCP BOOTP or manual configuration for the TCP IP network settings SNMP Agent Web server Console interface UPS status alarms readings event logging over different interfaces Digital outputs open collector outputs for relay drive 1 ph plug in version only SNMP Traps and E mail notification upon UPS event Advanced security features 2 4 ARCHITECTURE m ARCHITECTURE DIAGRAM indows UPS E UNIX Sat eee 10 100 Mbit s IS UTP Contact i f 1 ph plug in version only 1 1 RS232 Ethernet es Local console NOTE only required for configuration Modifications reserved ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Page 12 24 Installation Guide SNMP Web Adapter 2 5 ADDITIONAL DOCUMENTS The SNMP Web adapter is provided with a CD ROM containing the following documentation e Installation Manual e Operating Manual e SNMP Management Information Base MIB e Release notes and other instructions as applicable Modifications reserved Page 13 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 3 INSTALLATION NOTE Strictly observe the UPS Safety Rules Read carefully the UPS Operating Manual amp Installation Guide before installing or operating the equipment
6. received from the adapter verify the adapter installation cabling and network configuration Check the Ethernet connection to the adapter by launching a ping command from a workstation in the same subnet E g in a Windows system e Select Run from the Start menu e Enter ping lt IP gt e g ping 192 168 24 14 e Verify that the SNMP Card adapter is correctly replying 5 3 FURTHER INFORMATION For more information and in order to make full use of all advanced functionalities provided by the SNMP Web adapter refer to the Operating Manual available on the CD ROM Modifications reserved Page 22 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 6 CUSTOMER SUPPORT 6 1 FIRST LINE SUPPORT Please contact your local GE distributor for problems with the installation of the product or its use 6 2 INTERNET On line support available on request Internet access required 6 3 WWW SERVER We have a WWW server running at www gedigitalenergy com With your favourite web browser you can access the latest information from GE and download updates and manuals for this product Modifications reserved Page 23 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 7 APPENDIX A SitePro EARTH CONNECTION In order to guarantee correct functional behaviour the SNMP Web plug in adapter must be connected to protective earth UPS chassis On SitePro UPSs manufactured before 2003 the square plates d
7. GE Digital Energy Power Quality Installation Guide Digital Energy SNMP WEB ADAPTER P N 1018959 3 ph SNMP Web plug in adapter P N 1019070 1 ph SNMP Web plug in adapter P N 23954 SP SNMP Web plug in adapter P N 1019071 1 ph SNMP Web external adapter GE Consumer amp Industrial SA General Electric Company CH 6595 Riazzino Locarno Switzerland T 41 0 91 85051 51 F 41 0 91 850 51 44 www gedigitalenergy com A GE imagination at work sae ISO 9001 Reg No CSQ 9130 GELE 3 ph SNMP Web plug in adapter 1 ph SNMP Web plug in adapter Boge SP SNMP Web plug in adapter 1 ph SNMP Web external adapter Date of issue 13 05 2008 File name ISG_CNT_SNM_BAS_CRD_V012 Revision 1 2 P N 1018959 P N 1019070 P N 23954 P N 1019071 Identification No Up dating Revision Concerns Date 1 0 First Issue 20 12 2007 1 1 First RELEASED Issued 15 02 2008 1 2 Updated for the 3 ph and SP SNMP Web plug in adapters 13 05 2008 COPYRIGHT 2008 by GE Consumer amp Industrial SA All rights reserved The information contained in this publication is intended solely for the purposes indicated The present publication and any other documentation supplied with the UPS system is not to be reproduced either in part or in its entirety without the prior written consent of GE The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete
8. HW reset Contact interface open collector output SP SNMP Web plug in adapter P N 23954 uJ LAN O Front Panel User Interface E 232 set View UTP 10 100 a i E e 1 RJ45 Connector e 2 LEDs e 3 RS 232 port e 4 Reset button y Ethernet connection 10Base T or 100Base TX Ref specific section Local console connection 115200 N 8 1 HW reset 1 ph SNMP Web external adapter P N 1019071 UPS SNMP Interface o rese S active Net link Front Faut View o Wo o a H Rear e 1 RJ45 Connector e 2 LEDs e 3 RS 232 port e 4 Reset button e 6 Power in e 7 UPS port Modifications reserved ISG_CNT_SNM_BAS_CRD_1GB_V012 doc CONSOLE UP View 1 o Ethernet connection 10Base T or 100Base TX Ref specific section Local console connection 115200 N 8 1 HW reset AC adapter connection RS 232 connection to the UPS Page 11 24 Installation Guide SNMP Web Adapter LEDs The various front panel LEDs have the following meaning 2 3 LAN Netlink Status Meaning Off No LAN connection detected On LAN connection established no communication Blink LAN connection established receive or transmit active UPS Fail Status Meaning Off OK No Fault On No UPS Connection Active Status Meaning Off Fault of device Blink Device OK No fault FEATURES Each SNMP Web adapter provides the
9. Switch off the UPS and wait approx 2 minutes or switch the UPS to the manual bypass In the latter case please ensure that the mains input is reliable during this period e Install the SNMP WEB Interface card in the RS232 option slot For more details about the slot please read the UPS user manual a y Ge La Modifications reserved Page 16 24 ISG_CNT_SNM_BAS_CRD_1GB_VO12 doc Installation Guide SNMP Web Adapter e Make all necessary connections see architecture diagram in section 2 4 Contact i f 0 000 gi gt oji e Switch on the UPS or go back to normal mode from bypass 3 3 SP SNMP WEB PLUG IN ADAPTER P N 1019070 e Switch off the UPS and wait approx 2 minutes or switch the UPS to the manual bypass In the latter case please ensure that the mains input is reliable during this period e Install the SNMP WEB Interface card in the option slot For more details about the slot please read the UPS user manual Gey si LJ e Switch on the UPS or go back to normal mode from bypass 3 4 1 PH SNMP WEB EXTERNAL ADAPTER P N 1019071 CONSOLE UPS i o L w Gy e Connect the network cable to the box
10. T_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 1 SAFETY RULES With this document GE gives to the user all the necessary information about the correct installation of the SNMP Web adapters Please read carefully this Installation Manual before installing or operating the adapters We recommend that this manual be kept next to the UPS for future references If any problems are encountered with the procedures contained in this manual please contact the nearest Service Centre before you proceed For more information on the UPS system please refer to the applicable Installation and User Manual All maintenance and service work should be performed by qualified service personnel only The KNOWLEDGE of and FULL compliance to the safety instructions and the warning contained in this manual are THE ONLY CONDITION to avoid any dangerous situations during installation operation maintenance work and to preserve the maximum reliability of the UPS system NOTE While every care has been taken to ensure the completeness and accuracy of this manual GE assumes no responsibility or liability for any losses or damages resulting from the use of the information contained in this document GE Refuses any responsibility in case of non observance unauthorised alterations or improper use of the delivered equipment Modifications reserved Page 5 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter
11. The DB9 and RJ11 port share the same GND signal Exercise caution when both interfaces are used at the same time particularly when connecting these interfaces to non floating ground systems Modifications reserved Page 18 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 4 CONFIGURATION 4 1 CONFIGURATION METHODS The SNMP Web plug in adapters can be configured using different interfaces 4 1 1 Configuration via serial connection e Connect the SNMP adapter to a computer using a standard 1 1 serial communication cable e Runa terminal simulator e g HyperTerminal on a PC running Windows e Configure the terminal simulator as follows 115 200bps 8 data bits 1stop bit paritynone flow control none Terminal emulation VT 100 SNMP 115200 Properties 2 x Port Settings Bits per second ris200 y Data bits fe y Parity None Stop bits h y Flow control Restore Defaults Cancel Apply Establish the connection and press lt enter gt ConnectTo Settings M Function arrow and ctrl keys act as Terminal keys Windows keys M Backspace key sends CtleH Del Ctl H Space Ctrl H Emulation vr oo y Terminal Setup Telnet terminal ID vr 100 Backscroll buffer lines 500 7 Play sound when connecting or disconnecting Input Translation The default username login and password are ge and ge A command lin
12. ake care the plate does not fall inside the UPS 2 Slide carefully the SNMP adapter into the Options slot 3 Fix the front plate of the SNMP adapter to the UPS using the screw included in the SNMP Web adapter kit Install procedure for SitePro S6 Connectivity box PROTECTION Il PLATE l immu 4 ji an Ui 1 Change the front plate with the smaller one delivered with the Kit 2 Insert the SNMP adapter in the options slot 3 Fix the front plate of the SNMP adapter to the connectivity box using the screw included in the SNMP Web adapter kit Modifications reserved Page 15 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter Install procedure for SG Series Connectivity box P4 Adv SNMP Card ox Protection Plate 1 Change the front plate with the smaller one delivered with the Kit 2 Insert the SNMP adapter in the options slot 3 Fix the front plate of the SNMP adapter to the connectivity box using the screw included in the SNMP Web adapter kit 3 1 3 Connecting the card Refer to the architecture detailed in Section 2 4 Now the UPS may be switched on or back to normal mode from manual bypass 3 2 1 PH SNMP WEB PLUG IN ADAPTER P N 1019070 e
13. douswaste perchlorate Modifications reserved Page 7 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 1 2 EMC COMPATIBILITY 1 ph SNMP Web plug in adapter P N 1019070 1 ph SNMP Web external adapter P N 1019071 This device has been tested for compliance with the following standards e EN 61000 6 2 e EN 61000 6 3 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help 3 ph SNMP Web plug in adapter P N
14. e Launch a telnet client e g on a PC running Windows select Run from the Start menu and type telnet lt IP gt e The default username login and password are ge and ge e Acommand line configuration interface is entered WEB BROWSER e Launch a web browser e Enter the URL of the SNMP Web adapter http lt IP gt e The default username and password are ge and ge e Navigate the pages using the menu bar NOTE Save the settings Apart from some network parameters most setting are immediately active However the adapter will revert to the last saved settings at reboot Therefore in order to permanently modify the SNMP Web adapter setting remember to save the configuration after every change Modifications reserved Page 20 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 4 2 NETWORK PARAMETERS The SNMP Web adapter connects to the network using the following parameters e IP address identifies the adapter on the network e Subnet mask defines a range of addresses within the organisation e Gateway the node used for connection to addresses outside the subnet The adapter can be configured to obtain these settings automatically using DHCP or BOOTP protocols or to use static addresses manual configuration 4 2 1 Default configuration The SNMP Web adapter comes with a pre configured MAC address with the following format 00 12 93 Fx xx xx 00 12 93 identifies the manufacturer x xx xx IS a unique c
15. e configuration interface is entered Type menu to enter the quick network configuration menu SNMP 115200 HyperTerminal loj xj Fie Edit View Call Transfer Help Djs 213 cls l Active IP 3 18 196 201 Mask 255 255 254 0 Gateway 3 18 196 1 boot method DHCP IP Address 192 168 1 89 Modifications reserved ISG_CNT_SNM_BAS_CRD_1GB_VO12 doc Subnet Mask 255 255 255 0 Gateway 192 168 1 254 Save settings Reboot Help Quit_ Connected 2 14 19 yT100 1152008 0 1 scrOLL cars Num Capture Print echo Page 19 24 Installation Guide SNMP Web Adapter NOTE Although the console interface provides a full set of commands access using the serial connection is only needed for initial configuration when no DHCP server is available or the IP address is unknown The quick network configuration menu provides a simple interface for basic network configuration For all other settings the user friendly web interface is recommended NOTE Save the settings Apart from some network parameters most setting are immediately active However the adapter will revert to the last saved settings at reboot Therefore in order to permanently modify the SNMP Web adapter setting remember to save the configuration after every change This can be done e Pressing S on the quick configuration menu e Entering nvsave at the command interface prompt 4 1 2 Configuration via the network TELNET
16. elivered with the 3 ph adapter kit must be mounted refer to the pictures below for the installation details Note Should the UPS be already equipped with the plates please ignore this step Square plates a Square plates mounting position Square plate mounting detail Plug in adapter earth connection Modifications reserved Page 24 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter
17. in every detail The content of this publication may be subject to modification without prior notice Dear Customer We thank you for selecting our products and are pleased to count you amongst our very valued customers at GE We trust that the use of the SNMP Web adapters for our Uninterruptible Power Supply systems developed and produced to the highest standards of quality will give you complete satisfaction Please read carefully the Installation Manual which contains all the necessary information about the installation of the adapters Thank you for choosing GE Distributed by Your service contact GE Digital Energy General Electric Company CH 6595 Riazzino Locarno Switzerland Modifications reserved ISG_CNT_SNM_BAS_CRD_1GB_VO012 doc Page 3 24 Installation Guide SNMP Web Adapter Table of contents Page Ti SAFETY AA avait Aiea Aa ail cae EG hah AAE 5 LT WARNINGS ANDi CAUTO N Sareetan A Ea A A A E AAAA 6 PAs EMCCOMPATIBI e A a o 8 2 INTRODUCTION cad 9 2 1 CHECKING PACKAGECONTENTS ee de ee RRG 9 22 OVERVIEW dd 10 23 FEATURE Srm are A TT A tee Ud a A E A le K a 12 ZA ARCHITECTURE A HERCEGE 12 2 5 ADDITIONAL DOGCUMENTS aci n 13 Ss INSTALLATION sirenita coses 3 1 3 PH SNMP WEB PLUG IN ADAPTER P N 1018959 3 1 1 Setting the logical address oooococonnnncnnnninnnoss 3 12 Installing the SNMP Card in Option Slote ccccsssssssssssssssssccecscsssss
18. manual e Third Party License ReadMe e CD ROM Plates for old SitePro UPS ref Appendix A Front panel for LP33 Series UPSs 1 ph SNMP Web plug in adapter P N 1019070 SP SNMP Web plug in adapter P N 23954 e 1 ph SNMP Web plug in adapter e Installation manual e Third Party License ReadMe e CD ROM SP SNMP Web plug in adapter P N 23954 e SPSNMP Web plug in adapter e Installation manual e Third Party License ReadMe e CD ROM 1 ph SNMP Web external adapter P N 1019071 e 1 ph SNMP Web external adapter e AC adapter e Serial communication cable e Installation Manual Modifications reserved Page 9 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter e Third Party License ReadMe e CD ROM AC adapter Serial cable 2 2 OVERVIEW 3 ph SNMP Web plug in adapter P N 1018959 LP 33 Series UPS SitePro SG Series UPS e 1 RJ45 Connector Ethernet connection 10Base T or 100Base TX e 2 LEDs Ref specific section e 3 RS 232 port Local console connection 115200 N 8 1 e 4 Reset button HW reset 1 ph SNMP Web plug in adapter P N 1019070 Front Panel User Interface View Modifications reserved Page 10 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter e 1 RJ45 Connector e 2 LEDs e 3 RS 232 port e 4 Reset button e 5 RJ11 Connector Ethernet connection 10Base T or 100Base TX Ref specific section Local console connection 115200 N 8 1
19. ode for every adapter The MAC address is written on a label sticker on the SNMP Web adapter The factory default configuration for the SNMP Web adapter is using DHCP Assign the IP address to the adapter MAC address in your DHCP server Then reboot the adapter in order to have it retrieve the IP address The adapter is now accessible and configurable over the network 4 2 2 Reboot Every time the network settings are changed these become effective only after a reboot The adapter can be rebooted e Manually pressing the reset button on the front of the adapter e Using the console interface either serial connection or telnet by injecting the reboot command e Using a web browser selecting Reboot in the menu 4 3 FURTHER INFORMATION For more information and in order to make full use of all advanced functionalities provided by the SNMP Web adapter refer to the Operating Manual available on the CD ROM Modifications reserved Page 21 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter 5 ACCESS 5 1 WEB INTERFACE After the installation and configuration of the SNMP Web adapter the connection can be tested with a web browser e Launch the browser e Enter the URL of the SNMP Web adapter http lt IP gt e g http 192 168 24 14 e When prompted enter username and password by default these are set to ge and ge e The SNMP Web adapter home page will be shown 5 2 TROUBLESHOOTING If no answer is
20. sssssceseseecessssssssnunsssesseseesesssssssnuusseeseseeeeessssssssnusssecseseeeessnnueseees LI i Connecting the COC doc 3 2 1 PH SNMP WEB PLUG IN ADAPTER P N 1019070 3 3 SPSNMP WEB PLUG IN ADAPTER P N 1019070 ssssssssssssussssssessssessussssssssesessususssssesssessuuusssssessseseuusassseseseseuaussssseees 3 4 1 PHSNMP WEB EXTERNAL ADAPTER P N 101907 1 cccccssssssssseessessssssnsssssssssnssssssssesseseessstussutsustiissssssssssssnsessessseee 17 3 5 INTERFACES O ld eects BEA 18 Gs CONFIGURATION 2 A Ai IA 4 1 CONFIGURATION METHODS 4 1 1 Configuration via serial connection 4 1 2 Configuration via the NetWork Qe essssssscsscssssssssssnsssesescecesssssssnnusscesseeeeeessssssusuumuseeseseeeeessssssusnuussseeeeeeeeesssssssnnuuscseeseesssssunuaneseceeseees 42 NETWORK PARAMETERS ccoo ac alii Ar2 1 Default COMTI OM PORRO POPPROOCOO 0 054NE CL EEr OR NNA O O B22 RED OO a a a E E E e an da 4 37 EURTHERINRORMATION ita nc a A ote ee aa ee Raa So ACE St ERE A EA TETTE EO 22 SL WEBINTERFACE arr E e e 22 5 2 TROUBLESHOOTING Gi ninnirireciniiini ches iTar an VE REEE TEREA RARO CRR GNE 22 925 BURTHER INRORMATION a a a A A ERI 22 62 CUSTOMER SUPPORT aa da ias 23 61 ERSTUNESUPBRO RT ieee ace Ree E E aes ie el es ee 23 6 2 VINTERNE Poroninie dik See TERE ANRETT TEO OO AR EE wheal Gaede aledls 23 63 WWW SERVER o a aaa a r a aa aana iN E ASE EE EAE aa aV S 23 T APPENDIX A jerccsicss socacces cceceste ON 24 Modifications reserved Page 4 24 ISG_CN
21. t should be placed in a sufficiently ventilated area the ambient temperature should not exceed 35 C 95 F BATTERY e The SNMP Web adapters contain a removable lithium coin cell battery The battery has been selected in order to power to the relevant devices for over 10 years therefore battery replacement should not be necessary and it is not recommended In any case replace only with batteries of the same type and properly dispose or recycle used batteries e Never dispose of battery in a fire they may explode e Donottry to open or mutilate battery their contents may be toxic e Never short circuit the battery Modifications reserved Page 6 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter ENVIRONMENT e Please take care of packaging material either save it for later use or recycle dispose in compliance with local and other applicable regulations e The SNMP Web adapters contain a removable Lithium coin cell battery Dispose of used batteries in compliance with local and other applicable regulations WARNING The UPS contains hazardous voltages Observe carefully the safety instructions to prevent risk of electrical shock CAUTION The SNMP Web adapter contains a lithium coin cell battery RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Perchlorate Material special handling may apply See www dtsc ca gov hazar