1.   100 volts  and in many other countries  220  230  or 240 volts  The actual voltage can  fall below or rise above this nominal level due  to brownouts  power cutbacks  use of substan   dard wiring  and other causes  These devia   tions can cause poor performance or a mal   function  A regulator is a device which  through  use of a transformer  corrects the voltage  deviation by stepping it up or down so that it is    as close as possible to the nominal level     SPIKE  A pulse of energy on the power line   Spikes can have voltages as high as 6000  volts  Though they are usually of very short du   ration  the energy they contain can be consid   erable  enough to damage sensitive solid state  components in audio and computer equipment   Spikes can also foul switch contacts and de   grade wiring insulation  They are an unavoid   able component of electric power  They are  caused unpredictably by electric motors switch   ing on or off  on the premises or outside   utility  company maintenance operations  nearby  lightning strikes  and other factors  Spikes  also  called surges or transients  are absorbed by  special components called MOV   s in the AR   series to provide safe voltage levels to protect  your equipment     RFI EMI INTERFERENCE  Noise from RFI   Radio Frequency Interference  or EMI  Electro  Magnetic Interference  involves lower voltages  and less energy than is found in spikes  but it is  continuous rather than transient in nature  It is  not likely to cause physi
2.   Furman Sound  LLC     1690 Corporate Circle e Petaluma  CA 94954 6919 USA  Phone  707 763 1010   Fax  707 763 1310    Web  www FurmanSound com    E mail  info furmansound com  12117 04 6 Made in China    
3.   date  this is not necessary if the Warranty Regis   tration was completed either via the mailed in  warranty card or on line website registration   Shipping charges to the Furman factory or to  an authorized repair location must be prepaid  by the Purchaser of the product  Manufacturer  shall  at its own expense  furnish a replacement  Product or  at Manufacturer   s option  repair the  defective Product  Return shipping charges  back to Purchaser will be paid by Manufacturer     THE FOREGOING IS IN LIEU OF ALL OTHER  WARRANTIES  EXPRESS OR IMPLIED   INCLUDING BUT NOT LIMITED TO THE IM   PLIED WARRANTIES OF MERCHANTABILITY  AND FITNESS FOR A PARTICULAR PUR   POSE  Manufacturer does not warrant against  damages or defects arising out of improper   or abnormal use of handling of the Product   against defects or damages arising from im   proper installation  against defects in products  or components not manufactured by Manufac   turer  or against damages resulting from such    non Manufacturer made products or compo   nents  This warranty shall be cancelable by  Manufacturer at its sole discretion if the product  is modified in any way without written authori   zation from Furman Sound  This warranty also  does not apply to Products upon which repairs  have been affected or attempted by persons  other than pursuant to written authorization by  Manufacturer     THIS WARRANTY IS EXCLUSIVE  The sole  and exclusive obligation of Manufacturer shall  be to repair or replace the def
4. AR 15    AC LINE VOLTAGE REGULATOR  AND  POWER CONDITIONER       FURMAN       Congratulations on your purchase of a  Furman AR 15 AC Line Voltage Regula   tor   Power Conditioner  The AR Series  regulators are designed specifically for  any audio  video  or computer rackmount  system requiring clean  filtered  and regu     lated AC power for optimum operation     AR 15 FEATURES    e Provides nine regulated  conditioned AC  outlets   eight on the rear panel and one on  the front    e Series Multi Stage Protection Plus   SMP   with extreme voltage shutdown   EVS     e LiFT  Linear Filtering Technology  with  zero ground contamination    e Eight rear panel outlets and one front  panel outlet       BNC connector on the rear panel allows  you to attach any standard  12VAC 0 5  amp  gooseneck lamp to illuminate the  rear of your rack    e Extreme Voltage Shutdown indicator LED  e Output In Regulation indicator  e Ten LED bargraph input voltmeter    e Fast acting user accessible circuit breaker  protects against overload or shorts    e Very low stray magnetic field leakage    e Input capacity is 15 A  output capacity is 12    to15A    SAFETY INFORMATION    To obtain best results from your Furman AR 15  please be sure to read this manual carefully     WARNING  To reduce the risk of electrical  shock  do not expose this equipment to rain or  moisture  Dangerous high voltages are present  inside the enclosure  Do not remove the cov   ers  There are no user serviceable parts inside   Re
5. above the high  cutoff voltage and has caused the unit to  remove power from its outlets  it cannot restore  power without the operator manually turning  the unit off  then on again  Avoid turning the  unit back on  without first checking the source  of the problem  and perhaps changing the AC    source     Protection OK Indicator   Although the Furman SMP   circuit assures  virtually protection from transient voltage  spikes and surges  nature has a way of  occasionally creating electrical forces that are  beyond the capabilities of any TVSS device to  absorb without some degree of damage  In  the rare instance that this occurs  the green     Protection OK    LED indicator located on your  front panel will dim  If this happens some level  of protection from voltage surges will remain   but the Furman   s clamping voltage rating will  be compromised  The unit must be returned  to Furman Sound  or an authorized Furman  Service center for repair     FUSES AND CIRCUIT BREAKERS    There is one fuse and one circuit breaker in the  AR Series  In the event that the unit appears to  be completely dead  neither the Power switch  nor any LED   s light up   unplug the power cord  and the load and check the breaker  If the cir   cuit breaker is tripped  a white button will pop  up  Push it back in to reset it  The purposes of  these circuit protection devices are     1  Afast blow 15 amp circuit breaker is acces   sible at the rear panel without removing the    unit from the rack  This b
6. cal damage  but it can  certainly be annoying  producing static in audio  circuits     snow    on video screens  or garbled  data in computers  Noise can be introduced into  AC lines by nearby radio transmitters  certain  kinds of lighting  electric motors  and others   Because noise occurs at higher frequencies  than the 50 or 60 Hz AC line  it can be effective   ly reduced through use of low pass filtering     THREE YEAR LIMITED WARRANTY    Furman Sound  LLC   having its principal place  of business at 1690 Corporate Circle  Petaluma   CA 94954     Manufacturer     warrants its AR 15   the    Product     as follows     Manufacturer warrants to the original Purchaser  of the Product that the Product sold hereunder  will be free from defects in material and work   manship for a period of three years from the  date of purchase  The Purchaser of the product  is allowed fifteen days from the date of purchase  to complete warranty registration by mail or on   line at the Furman website  If the Product does  not conform to this Limited Warranty during the  warranty period  as herein above specified    Purchaser shall notify Manufacturer in writing of  the claimed defects  If the defects are of such  type and nature as to be covered by this war   ranty  Manufacturer shall authorize Purchaser  to return the Product to the Furman factory or to  an authorized Furman repair location  Warranty  claims should be accompanied by a copy of the  original purchase invoice showing the purchase
7. display your RA Number  prominently on the front of all packages     SPECIFICATIONS    Spike Protection Modes    Line to neutral  zero ground leakage  Spike Clamping Voltage    188 Vpk   3 000 amps  133 VAC RMS     tested to UL 1449 6 000 Vpk   3 000 amps     Response time   1 nanosecond    Maximum surge current   6 500 amps    Voltmeter Accuracy   45V       In Regulation    Ranges     AR 15 Il  Provides regulation  5V in 120V mode from  97 to 137V    Noise attenuation        AR 1215 Output Voltage    Functional Range             R  fo    Q           Regulation Range    yd              3  8  umopinys a  eyoA YIH    Output Volatge  o    Se     Low Voltage Shutdown                                      to        70 80 90 100 110 120 130 140 150 160  Input Voltage    AR 1215 Output Current Capability                   Available Output Current                            70 80 90 100 110 120 130 140 150 160  Input Voltage    10 dB   10 kHz  40 dB   100 kHz  100 dB   10 MHz    Linear attenuation curve from 0 05   100 ohms line impedance  Shutdown Range   Above 137 VAC typically    Dimensions   19   W x 11 63 D x 1 75   H   48 26 x 29 54 x 4 45 cm   Weight   14 5 Ibs   6 58 kg     Current Rating   The AR 15 Il is capable of 15 amps for input voltages  of 124V  104V in 100V mode  or higher  derate at 113  mA per volt to a minimum of 12 3A    Three Year Limited Warranty   The AR 15 is protected by a limited three year warranty covering defects  in materials and workmanship     FURMAN  
8. ective Product in  the manner and for the period provided above   Manufacturer shall not have any other obligation  with respect to the Products or any part thereof   whether based on contract  tort  strict liability or  otherwise  Under no circumstances  whether  based on this Limited Warranty or otherwise   shall Manufacturer be liable for incidental   special  or consequential damages  Manufac   turer   s employees or representatives    ORAL OR  OTHER WRITTEN STATEMENTS DO NOT  CONSTITUTE WARRANTIES  shall not be  relied upon by Purchaser  and are not a part of  the contract for sale or this limited warranty  This  Limited Warranty states the entire obligation of  Manufacturer with respect to the Product  If any  part of this Limited Warranty is determined to be  void or illegal  the remainder shall remain in full  force and effect     SERVICE    Before returning any equipment for repair   please be sure that it is adequately packed  and cushioned against damage in shipment   and that it is insured  We suggest that you  save the original packaging and use it to  ship the product for servicing  Also  please  enclose a note giving your name  address   phone number and a description of the  problem     NOTE  All equipment being returned for re   pair must have a Return Authorization  RA   Number  To get an RA Number  please call  the Furman Service Department   707  763   1010  ext  2370 or 2377  between 8 a m   and 5 p m  U S  Pacific Time  or fax to  707   763 1310  Please 
9. esis in  the switching circuits avoids    chatter    or unnec   essary switching back and forth between adja   cent taps  Unlike those voltage regulators that  employ ferro resonant transformers  Furman  Voltage Regulators are not sensitive to small    errors in line frequency  making them ideal for  use with generators     MAXIMUM AND MINIMUM LOAD    The AR 15 can handle loads totalling up to 15  amperes as long as the input voltage is equal  to or above 124 volts  For voltages below that  level  its capacity must be derated at approxi   mately 113 milliamperes per volt   See graphs  on back page   As a practical matter  therefore   to cope successfully with worst case brown   out conditions  you should plan your total load  so that it does not exceed 12 amps  or 1400  watts  Please note that this refers to the ag   gregate power requirement of all equipment  plugged into the Voltage Regulator  not to each  individual item     NOTE  While there is no minimum load require   ment for the AR 15 you may experience an  audible mechanical hum coming directly from the  unit when the POWER switch is on with nothing  plugged in  This effect will sometimes disappear  as soon as you plug in any equipment drawing 40  to 50 watts total     DEFINITIONS    VOLTAGE REGULATION  The AC line voltage  is a number indicating the nominal electrical  potential that has been adopted in a region   for powering electrical equipment of all kinds   In most of North America it is 117 volts AC  in  Japan
10. fer servicing to qualified personnel only     The lightning flash with arrowhead symbol   within an equilateral triangle  is intended to alert  the user to the presence of uninsulated danger   ous voltage within the product   s enclosure that  may be of sufficient magnitude to constitute a  risk of electric shock     IMPORTANT SAFETY  INSTRUCTIONS    PLEASE READ PRIOR TO INSTALLATION   1  Please read and observe all of the safety and  operating instructions before the AR 15 is  operated  Retain these instructions for future  reference     2  The AR 15 should not be used near water      for example  near a bathtub   kitchen sink  in a wet basement   near a swimming pool  etc     3 Do not place the AR 15 near   heat sources such as radiators   heat registers  stoves  or other appliances  that produce heat     4  Route the power cord and other cables so  that they are not likely to be walked on   tripped over  or stressed  Pay particular at   tention to condition of cords and cables at  plugs  and the point where they exit from the    AR 15  To prevent risk of fire or injury  dam   aged cords and cables should be replaced  immediately     5  Clean the AR 15 with a damp cloth only  Do not  use solvents or abrasive cleaners  Never pour  any liquid on or into the unit     6  When left unused for a long period of time   the power cord of the AR 15 should be un   plugged from the outlet     7  The AR 15 should be serviced by qualified  service personnel when    a  The power supply co
11. filter   conditioners  have been designed for unrealistic laboratory  conditions  Prior technologies could actu    ally harm audio and video performance more  than they help  due to the resonant peaking   of their antiquated  non linear designs  Under  certain conditions  these designs can actually  add more than 10 dB of noise to the incoming  AC line  Furman   s SMP  with LiFT takes an   other approach  ensuring optimal performance  through linear filtering and no leakage to  ground  With this exclusive filtration technol   ogy  all connected equipment will be free of  noise and contamination and will operate at  optimum performance levels     Extreme Voltage Shutdown Indicator  This LED is normally off  It monitors a hazard  common in the entertainment industry  wiring  faults     for example  accidental connection   to 220VAC where 120VAC is expected  or an  open neutral from a 208 or 240VAC feed  The  Series II SMP  circuit senses voltages that  are so high that operation would be impossible  and shuts the power down before damage   can occur  Upon initially applying power to  these units  the Extreme Voltage indicator  LED will light if the input voltage is above the  extreme voltage cutoff  and power will not be  applied to the unit   s outlets  If the unit has been    operating with an acceptable input voltage  and subsequently that voltage exceeds 145   150V  it will shut off power to the outlet and the  Extreme Voltage LED will light     NOTE  If the mains power is 
12. l are functionally interchangeable  The outlets  are regulated  surge suppressed  and linearly  filtered  making the unit a full function power  conditioner  The AR 15 has no controls except  an on off switch and the switch for the optional  rear rack light     Note  The AR 15 is for use with AC voltage  only  DC voltages should never be applied to  them  Also  it does not change or regulate line  frequency  The output frequency will always be  the same as the incoming frequency     SMP   Series Multi Stage Protection  Plus     Traditional surge suppression rely on circuits  that    sacrifice    themselves when exposed to  multiple transient voltage spikes  requiring the  dismantling of your system  and repair of your  surge suppressor  Not so with SMP   With  Furman   s SMP   damaging transient voltages  are safely absorbed  clamped  and dissipated   No sacrificed parts  no service calls  no down  time     Unique to Furman   s SMP   is its unparalleled  clamping voltage  While other designs offer  clamping voltages that are well above 330 Vpk     Furman   s SMP  clamps at 188 Vpk   133 VAC  RMS   This unprecedented level of protection  is only available with Furman   s SMP  technol   ogy  Additionally  Furman   s trusted over volt   age circuitry protects against all too frequent  accidental connections to 208 or 240 VAC  by  shutting off the incoming power until the over  voltage condition is corrected     LiFT  Linear Filtering Technology     Unfortunately  traditional AC 
13. lator output      INSTALLATION    Because of their toroidal transformer design   Furman Voltage Regulators may be posi   tioned near most other equipment without fear  that the other equipment will be disrupted by  leakage of a strong 50 60 Hz magnetic field   Nevertheless  suggested rack locations would  be either at the top or bottom     As with any rackmount equipment  be sure to  use 10 32 machine screws for mounting in the  rack   s tapped holes  this is not a metric size    In particular  beware of 10 24 screws  which  may fit if forced but which will strip the threads   To avoid marring the front panel finish  use  plastic washers under the screw heads     DESIGN    The AR Series uses a design based on an  eight tap toroidal autoformer  The toroidal de   sign assures minimal leakage of stray magnetic  fields  and  because of its high efficiency  a very  compact size for its rating  The Voltage Regula   tor   s circuitry monitors the incoming line voltage  with each cycle  comparing it to an extremely  precise voltage reference  accurate to 0 15    If a voltage fluctuation requires that a different  tap be selected  the new tap is electronically  switched exactly at the zero crossing  to avoid  distorting the AC waveform  If necessary  it can  switch taps as often as once each cycle  Most  commercial voltage regulators using multiple   tapped transformers switch taps at uncontrolled  times  thereby creating voltage spikes and  clicks that can leak into the audio  Hyster
14. rd or the plug has  been frayed  kinked  or cut    b  Objects have fallen or liquid has spilled  into the unit    c  The AR 15 has been exposed to rain or  other moisture    d  The AR 15 does not appear to operate  normally or exhibits a marked change in  performance    e  The AR 15 has been dropped  or the  enclosure damaged     8  The AR 15 requires that a safety ground be  present for proper operation  Any attempt to  operate the AR 15 without a safety ground  is considered improper operation and could  invalidate the warranty     9  There are no user serviceable parts in the  AR 15  Refer servicing to qualified service  personnel only     Voltage Regulation    Furman Voltage Regulators are intended to  protect sensitive electronic equipment from  problems caused by AC line voltage irregu   larities   brownouts or overvoltages that can  cause audio tonal changes  digital equipment  malfunction  such as loss of MIDI programs or    other data   or  in extreme cases  permanent  damage  They accept input voltages over a  wide AC voltage range and convert them to a  steady  stable output at the desired standard  voltage  plus or minus five volts  Voltages ap   proximately  10  beyond that range may be  converted to usable levels  depending on the  requirements of the equipment  This stable  voltage protects equipment and allows optimal  performance  See graphs on the back page     The AR 15 has eight outlets on the rear panel   and one convenience outlet on the front panel   Al
15. reaker will trip if the  unit   s 15 amp capacity is exceeded at any  time     2  Afast blow 1 4 amp fuse is located inside  the unit  This fuse will blow if the unit has  been connected to a voltage that is above  the range of the Extreme Voltage Shut   down circuitry  To replace it  the unit must  be completely disconnected from all power  and removed from its rack  The six hex head  screws and two Phillips head screws holding  the top cover must be removed  The internal  fuse is located in a holder on the printed circuit  board  Replace the fuse only with the exact  same type  1 4 fast blow      INPUT VOLTAGE MONITORING    The row of ten LED   s at the left of the front  panel make up a meter that indicates INPUT  VOLTAGE  Only one LED will light up at a time   There are two red LED   s at the endpoints  When  lit  they indicate that the input voltage may   be above or below the point where it can be  restored to the selected nominal output volt   age  though it may still be restored to a usable  level  but is not high or low enough to cause an  extreme voltage shutdown     OUTPUT VOLTAGE MONITORING    Agreen LED labelled OUTPUT IN REGULATION  indicates proper function  i e   that the output volt   age is within  5V of the selected output voltage    Your equipment will always work normally when  this light is on  and often will work satisfactorily  even when it is off     The AR 15 offers a 10 LED bargraph line voltage  meter to monitor the incoming line  the Voltage  Regu
    