Home

Frigidaire 318201533 Microwave Oven User Manual

image

Contents

1. Q Unpack the wall oven Remove the bottom trim taped on the oven side panel Find the 2 anti tip mounting screws included in the literature package e Insert the oven into the cabinet opening Slide oven inward leaving 1 3 8 cm clearance between the oven and front of cabinet see Figure 5 4 Pull the armored cable through the hole for it in the cabinet and toward the junction box while moving the appliance inward Push the oven in and against the cabinet 1 3 8 cm clearance between unit Figure 5 MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS O instal the Anti tip Mounting Screws Q Install the Bottom Trim The wall oven can tip when the door Place the top of the bottom trim over the side trim is open The anti tip mounting screws supplied tabs on each side of the oven below the oven door with the wall oven must be installed to prevent and fix it using the 2 screws supplied in the mounting tipping of the wall oven and injury to persons holes located on each side trim below the oven frame A The mounting holes in the side trims may be used see Figure 7 as a template to locate the appliance mounting screw holes see figure 6 B Use the two screws supplied to fix the appliance to the cabinet Bottom Trim Screws supplied Figure 6 Figure 7 MICROWAVE WA
2. Enel caja de juntas conectar el aparato y los cables residenciales como se muestra en la figura 3 Cable desde el suministro de energ a Alambre desnudo Alambre rojos Caja de empalmes Alambre desnudo Alambre verde o desnudo Conductor de uni n listado UL o CSA Cable de la estufa Figura 3 CAJA DE EMPALMES DE 3 ALAMBRES PUESTA A TIERRA INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE PARED Si el horno se usa en una instalaci n de circuito de ramal nuevo 1996 NEC en una casa rodante en un veh culo para recreaci n o si los c digos locales NO permiten la conexi n a tierra a trav s del cable neutral blanco el armaz n del electrodom stico NO TIENE QUE estar conectado al alambre neutro del sistema el ctrico de 4 alambres ver figura 4 1 Desconecte el suministro el ctrico 2 Separe el alambre verde o cobre desnudo y el alambre blanco del electrodom stico 3 Enel caja de juntas conectar el aparato y los cables residenciales como se muestra en la figura 4 Cable desde el suministro de energ a Alambre desnudo Alambre negros verde O desnudo Alambre blanco __ Conductor de uni n listado UL Cable de la estufa o CSA Figura 4 CAJA DE EMPALMES DE 4 ALAMBRES PUESTA A TIERRA Caja de empalmes Ubicaci n del n mero de modelo y de serie La placa con el n mero de serie est ubicada en la guarnici n interior lateral del horno y s
3. conexi n del neutro al final de la l nea el ctrica si es usado en los estados unidos una nueva instalaci n de circuito de bifurcaci n 1996 NEC casa rodante veh culos recreacionales o donde los c digos locales no permitan poner a tierra mediante el neutro blanco o en Canad desconectar la conexi n blanca de la verde y utilizar la conexi n a tierra para poner a tierra la unidad de acuerdo a los c digos locales conectar el neutro al circuito de bifurcaci n conductor neutro de manera usual Ver Figura 4 Si su electrodom stico va a ser conectado a una caja de conexi n puesta a tierra de 3 cables en los estados unidos solamente donde los c digos locales permitan conectar el conductor de poner a tierra electrodom stico con el neutro blanco ver Figura 3 NOTA AL ELECTRICISTA Los conductores de cable blindados provistos con este artefacto son aprobados por UL para la conexi n al alambrado de casa de un calibre mayor El aislamiento de los conductores est calificado para temperaturas m s altas que las del alambrado de la casa La capacidad de corriente del conductor est gobernada por la calificaci n de la temperatura del aislamiento alrededor del alambre en vez de solamente el calibre del alambre Donde los c digos locales permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco Solamente en los Estados Unidos vea figura 3 1 Desconecte el suministro el ctrico 2
4. Open see note 2 ee Electrical Suggested distance from floor oe a i L Min Junction Box 5 Wide Wood is 11 2 29 2 cm ses nd right or left side Minimum required distance is Figure 1 4 Y 11 4 cm PRODUCT DIMENSIONS O EA SE EA AA EEC 68 6cm Wall Oven 27 68 6 4234 108 6 248 62 5 24 62 2 76 2cm Wall Oven 30 76 2 42 108 6 28 71 8 24Y2 62 2 CUTOUT DIMENSIONS AND CABINET WIDTH MODEL CAE AA 68 6cm Wall Oven 247 63 2 25 64 1 41 104 5 41 104 8 27 s 68 9 Min 76 2cm Wall Oven 28 72 4 29 73 7 41 104 5 41 104 8 30 76 5 Min All dimensions are stated in inches and cm P N 318201533 0904 Rev A Printed in United States English pages 1 6 Espa ol p ginas 7 12 MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the combination oven 2 Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven Observe all governing codes and ordinances Be sure to leave these instructions with the consumer Oven door may be removed to facilitate installation THIS COMBINATION OVEN IS NOT APPROVED FOR STACKABLE OR SIDE BY SIDE INSTALLATION Ox UT RW Important Note to the Consumer Keep these instructions with your Owner s Guide for future referenc
5. adecuada puede ser peligroso La corriente el ctrica al horno debe estar apagada mientras se hacen las conexiones de l neas Si no se apaga da os serios o la muerte podr an resultar 1 Carpinter a Consulte la Figura 1 para conocer las dimensiones pertinentes al modelo de su horno y al espacio necesario en el que poner el horno La superficie donde se va a apoyar el horno debe de ser de madera contrachapada s lida u otro material similar y sobre todo la superficie tiene que estar a nivel de lado a lado y de atr s hacia adelante electrodom stico 2 Requerimientos El ctricos Se debe proveer el voltaje y la frecuencia apropiados a este electrodom stico y conectarse a un circuito individual correctamente puesto a tierra protegido por un interruptor o un fusible Para conocer el interruptor o fusible que requiere su modelo vea la placa serial para encontrar la consumaci n del vatiaje y refierase al cuadro A para encontrar el amperaje del interruptor o fusible Grados de Se recomienda Vatios del una electrodom stico protecci n al 208V circuito Menos de 4100W 20A 4100W 6200W 30A 6200W 8300W 40A 8300W and 50A Table A Observe todos los c digos que gobiernan y ordenanzas locales 1 Un cable de 3 o 4 alambres monof sico 120 240 o 120 208 voltios 60 hertzios es la nica fuente el ctrica que requiere en un circuito separado en ambos lados de la l nea alambre negro y alambre rojo se reco
6. en este manual antes de instalar el combinaci n microondas horno de pared 2 Saque todo el material usado en el embalaje del compartimiento del horno antes de conectar el suministro el ctrico o de gas a la estufa Observe todos los c digos y reglamentos pertinentes Deje estas instrucciones con el consumidor La puerta del horno se puede retirar para facilitar la instalaci n 6 ESTE COMBINACI N MICROONDAS HORNO DE PARED NO EST APROBADO PARA LA INSTALACI N APILABLE O DE LADO A LADO US Yu Nota importante al consumidor Conserve estas instrucciones y el manual del usuario para referencia futura No tirar las herramientas para retirar el horno incluidas en la bolsa de la literatura INSTRUCCIONES IMPORTANTES DE SEGURIDAD e Aseg rese de que su combinaci n microondas horno de pared sea instalado y puesto a tierra de forma apropiada por un instalador calificado o por un t cnico de servicio e Este horno de pared debe ser el ctricamente puesto a tierra de acuerdo con los c digos locales o en su ausencia con el C digo El ctrico Nacional ANSI NFPA No 70 ltima edici n en los Estados Unidos o el C digo El ctrico Canadiense CSA Standard C22 1 Part 1 en Canad YMA Pisar apoyarse o sentarse sobre la puerta de este horno de pared puede causar serias lesiones y da os al horno de pared e Nunca use su horno de pared para calentar una habitaci n El uso prolongado de la estufa sin la ventilaci n
7. ARED Instalaci n de los tornillos de montado El horno de pared puede inclinarse cuando la puerta esta abierta Los soportes de montaje que vienen con el horno de pared deben de estar ajustadas al armario y al aparato para evitar que el horno de pared se incline y ocasione quemaduras graves A Los barrenos en las molduras laterales pueden ser usadas como gu a para localizar los tornillos de montado de la unidad figura 6 B Use los dos tornillos proporcionados para colocar la unidad en la cabina Tornillos de montado Figura 6 D Instalaci n de la Guarnici n Inferior Colocar la parte superior de la guarnici n inferior sobre las leng etas laterales del horno debajo de la puerta del horno y fijarlas usando los 2 tornillos provistos con los orificios de montaje ubicados a cada lado del marco del horno ver la Figura 7 Guarnici n Inferior Tornillos provistos Figura 7 INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE PARED 6 Aseg rese de que el horno de pared est a nivel 1 Instale una rejilla al centro del horno superior vea la Figura 8 Ponga un nivel por encima de la rejilla Lea 2 veces una vez con el nivel a la posici n de lado a lado y otra vez de atr s hacia adelante Utilice trozo de madera o cu as por debajo del horno de
8. COMBINATION INSTALLATION INSTRUCTIONS If oven is used in a new branch circuit installation 1996 NEC mobile home recreational vehicle or where local codes DO NOT permit grounding through the neutral white wire the appliance frame MUST NOT be connected to the neutral wire of the 4 wire electrical system see figure 4 1 Disconnect the power supply 2 Separate the green or bare copper and white appliance cable wires 3 In the junction box connect appliance and power supply cable wires as shown in Figure 4 Cable from Power Supply Ground Wire Red Ground Wire _ Bare or Green Wire Junction Box i White Wire 5 U L Listed Conduit Connector or CSA Cable from appliance listed Figure 4 4 WIRE GROUNDED JUNCTION BOX Model and Serial Number Location The serial plate is located along the interior side trim of the oven and visible when the door is opened When ordering parts for or making inquires about your oven always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven Serial Plate Location 4 Cabinet Installation IMPORTANT NOTE Do not lift the oven by the door handle ANTE Heavy Weight Hazard e Use 2 or more people to move and install wall oven e Failure to follow this instruction can result in injury or damage to the unit
9. LL OVEN COMBINATION INSTALLATION INSTRUCTIONS 5 Leveling the Wall Oven 1 2 Install an oven rack in the center of the upper oven see Figure 8 Place a level on the rack Take 2 readings with the level placed diagonally in one direction and then the other Use wood shims under the wall oven to level if necessary Repeat in the lower oven if you have a double cavity wall oven If the level indicates that the rack is not level use wood shims to reach a compromise for both ovens Figure 8 IMPORTANT NOTE A cooling fan inside the upper rear part above the oven some models provides cooling of the oven electrical and electronic components If the oven has been operating at high temperatures the fan will continue to run after the oven is turned off 7 Checking Operation Your model is equipped with an Electronic Oven Control Each of the functions has been factory checked before shipping However it is suggested that you verify the operation of the electronic oven controls once more Refer to the Use and Care Guide for operation 1 Remove all items from the inside of the oven 2 Turn on the power to the oven Refer to your Use amp Care Guide 3 Verify the operation of the electronic oven controls Bake Verify that this function makes the oven hot 20 seconds after turning oven on open the door and you should feel heat coming from the oven Broil When the oven is set to BROIL the
10. MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE E A WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance United States Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing easier The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below for your UL model You may find little or no cabinet work is necessary WAIN po not remove spacers if equipped on the side walls and or on the back of the built in oven These spacers center the oven in the space provided The oven must be centered to prevent excess heat buildup that may result in heat damage or fire NOTES Hole for Base must be capable of supporting 225 pounds 102 kg Cable Allow at least 21 53 3 cm clearance in front of oven for door 1 2 5 cm right or depth when it is open l left side Dimension G cutout depth is depending critical to the proper installation enamogey of the built in oven If the oven decorative trim does not butt against the cabinet verify dimension G to assure it is the required depth 3 7 6 cm Door
11. a hacer una reparaci n 3 Se debe de usar un conector que reduzca la tirantez de una forma adecuada para unir el cable blindado flexible a la caja de empalme INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE PARED ADVERTENCIA Riesgo de choque el ctrico Una puesta a tierra se requiere en este aparato No lo conecte a la corriente el ctrica hasta que el aparato haya sido puesto a tierra Desconecte la corriente el ctrica a la caja de empalmes antes de hacer la conexi n el ctrica Este aparato debe estar conectado con un sistema de alambres puesto en tierra met lico y permanente o un conector de puesta a tierra debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato No utilice el suministro de gas para hacer la puesta a tierra La falta de cualquiera de las instrucciones mencionadas podr a resultar en un incendio choque el ctrico o lesiones personales NAAMA En cuanto a las condiciones de despacho y almacenamiento en el invierno aseg rese de que el horno llegue a su destino final como m nimo tres 3 horas antes de encenderlo Si se enciende el horno cuando a n est fr o se pueden da ar los controles 4 Conexi n el ctrica El usuario tiene la responsabilidad personal y obligaci n de utilizar un instalador calificado para asegurar que la instalaci n el ctrica est hacha de forma adecuada y est conforme con el C digo El ctrico Nac
12. e Do not discard oven removal tools found in the literature bag IMPORTANT SAFETY INSTRUCTIONS e Be sure your combination oven is installed and grounded properly by a qualified installer or service technician e This wall oven must be electrically grounded in accordance with local codes or in their absence with the National Electrical Code ANSI NFPA No 70 latest edition in United Sates or with CSA Standard C22 1 Canadian Electrical Code Part 1 in Canada Stepping leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven e Never use your wall oven for warming or heating the room Prolonged use of the wall oven without adequate ventilation can be dangerous PNWAING The electrical power to the oven must be shut off while line connections are being made Failure to do so could result in serious injury or death 1 Carpentry Refer to figure 1 for the dimensions applicable to your appliance and the space necessary to receive the combination oven The oven support surface may be solid plywood or similar material however the surface must be leveled from side to side and from front to rear 2 Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model
13. e puede ver cuando se abre la puerta 5 Instalaci n del Gabinete IMPORTANTE No levante el horno por la manija de la puerta ADVERTENCIA Peligro de Peso Pesado e Use 2 personas o m s para mover e instalar el horno de pared e Si no cumple con esta instrucci n puede resultar en lesiones personales o da os al horno de pared Cuando haga pedidos de repuestos o solicite informaci n con respecto a su horno est siempre seguro de incluir el n mero de modelo y de serie y el n mero O letra del lote de la placa de serie de su horno La placa de serie est ubicada aqu O Desembalar el horno de pared Extraer la guarnici n inferior y los 2 tornillos unidos con cinta al panel lateral del horno Buscar los tornillos que se incluyen en el paquete de literatura Insertar el horno en la abertura del gabinete Deslizar el horno hacia dentro dejando 1 2 3 8 cm de espacio libre entre el horno y la parte delantera del gabinete ver la Figura 5 Empujar el cable blindado a trav s del orificio del gabinete y hacia la caja de paso mientras se desliza el accesorio hacia adentro Ot mpujar el horno hacia adentro y en contra del gabinete 11 2 3 8 cm distancia entre la unidad y el gabinete Figura 5 INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE P
14. e responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances Risk of electrical shock Failure to heed this warning may result in electrocution or other serious injury This appliance is equipped with copper lead wire If connection is made to aluminum house wiring use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code and local code and ordinances When installing connectors having screws which bear directly on the steel and or aluminum flexible conduit do no tighten screws sufficiently to damage the flexible conduit Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires DO NOT ground to a gas supply pipe DO NOT connect to electrical power supply until appliance is permanently grounded Connect the ground wire before turning on the power If your appliance is equipped with a white neutral conductor This appliance is manufactured with a white neutral power supply and a frame connected copper wire The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circu
15. es should be connected to the fused disconnect or circuit breaker box through flexible armored or nonmetallic sheathed cable The flexible armored cable extending from the appliance should be connected directly to the junction box The junction box should be located as shown in Figure 1 or Figure 2 and with as much slack as possible remaining in the cable between the box and the appliance so it can be moved if servicing is ever necessary 3 A suitable strain relief must be provided to attach the flexible armored cable to the junction box MICROWAVE WALL OVEN COMBINATION INSTALLATION INSTRUCTIONS WARNING Electrical Shock Hazard Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the junction box before making the electrical connection This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance Do not use a gas supply line for grounding the appliance Failure to do any of the above could result in a fire personal injury or electrical shock INTI in cold weather shipping and storage conditions make sure that oven is in final location at least three 3 hours before switching on power Switching on power while oven is still cold may damage the oven controls 3 Electrical connection It is th
16. ional ANSI NFPA No 70 ltima edici n en los Estados Unidos o el C digo El ctrico Canadiense CSA Standard C22 1 Part 1 en Canad ADVERTENCIA Riesgo de choque el ctrico El no prestar atenci n a esta advertencia puede resultar en electrocuci n u otras lesiones graves Este electrodom stico est equipado con alambre de cobre Si se va a conectar con cableado de aluminio del hogar utilizar nicamente conectores que est n aprobados para unir cobre y aluminio de acuerdo al C digo Nacional El ctrico NEC por sus siglas en ingles y leyes y c digos locales Al instalar conectores con tornillos que empujen directamente contra el acero y o aluminio del conducto flexible no apretar los tornillos suficientemente que da en el conducto flexible No doblar de m s o deformar el conducto flexible para evitar separar el espiral y descubrir los alambres internos NO conecte el alambre puesto a tierra a una tuber a de suministro de gas NO conecte el suministro de energ a el ctrica hasta que el electrodom stico haya sido permanentemente puesto a tierra Conecte el alambre de puesto a tierra antes de enchufar por primera vez el electrodom stico Si su electrodom stico est equipado con un conductor neutro blanco Este electrodom stico est fabricado con un suministro el ctrico neutro blanco y un alambre de cobre conectado al armaz n El armaz n esta puesto a tierra por un enlace de la conexi n a tierra con la
17. it installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead to branch circuit neutral conductor in usual manner see Figure 4 If your appliance is to be connected to a 3 wire grounded junction box US only where local code permit connecting the appliance grounding conductor to the neutral white see Figure 3 NOTE TO ELECTRICIAN The armored cable leads supplied with the appliance are UL recognized for connection to larger gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire rather than the wire gauge alone Where local codes permit connecting the appliance grounding conductor to the neutral white wire US Only see figure 3 1 Disconnect the power supply 2 In the junction box connect appliance and power supply cable wires as shown in Figure 3 Cable from Power Supply White Wire Neutral Red White Wire Lf Neutral U L Listed Conduit Connector or CSA listed Ground Wire Bare or Green Wire Cable from appliance Figure 3 3 WIRE GROUNDED JUNCTION BOX MICROWAVE WALL OVEN
18. mienda un fusible o un interruptor de retraso de tiempo No funda a cable neutro alambre blanco Se debe de tener precauci n al combinar un horno de pared y una cubierta refi rase a la placa de seria de cada uno de los aparatos Grados de Se recomienda Vatios del una protecci n al 240V circuito NOTA Los tama os y las conexiones del alambre deben conformarse con el tama o del fusible y el grado de la aplicaci n de acuerdo con el c digo El ctrico Nacional Americano ANSI NFPA No 70 ultima edici n o con el est ndar CSA canadiense C22 1 c digo el ctrico canadiense parte 1 y c digos y ordenanzas locales ADVERTENCIA No se debera usar extensiones para enchufar este electrodom stico Esto podr a causar un incendio choque el ctrico u otro tipo de da o personal Si usted necesita un cable mas largo puede ordernar un cable de 10 kit 903056 9010 llamando al centro de Servicio 2 Este electrodom stico debe conectarse a la caja de fusibles o de cortocircuito por medio de un cable blindado flexible o un cable con forro no met lico El cable blindado flexible que va desde el electrodom stico debe de estar conectado directamente a la caja de empalme La caja de empalme debe de estar localizada en el lugar que se indica en la Figura 1 0 2 dejando tanto exceso de cable como sea posible entre la caja y el electrodom stico de forma que as el electrodom stico se pueda mover f cilmente si fuera necesario par
19. pared para nivelar si sea necesario Vuelve a empezar en el horno inferior Si el nivel muestra que la rejilla no esta a nivel utilice trozo de madera o cu as para componer ambos hornos 2 Figura 8 IMPORTANTE Un ventilador ubicado dentro de la parte trasera superior arriba del horno en algunos modelos permite la refrigeraci n de los componentes el ctricos y electr nicos de enfriamiento Si el horno ha estado funcionando a altas temperaturas el ventilador seguir funcionando despu s de apagar el horno 7 Verificaci n del funcionamiento Su modelo est equipado con un Control Electr nico de Horno Cada una de las funciones ha sido controlada en f brica antes del despacho Sin embargo le sugerimos verificar el funcionamiento de los controles electr nicos una vez m s Consulte la Gu a de Uso y Cuidado para ver el funcionamiento del horno 1 Extraer todos los elementos de la parte interior del horno Encender el horno Consular la Gu a de Uso y Cuidado Verificar el funcionamiento de los controles electr nicos del horno Hornear Verificar que esta funci n caliente el horno Veinte minutos despu s de encender el horno abrir la puerta y ver si se siente que el calor emana desde su interior Asar Cuando se pone el horno para asar el elemento de arriba del horno debe de ponerse rojo Antes de llamar al servicio Lea la secci n Lista de Antes de llamar en su Manual del Usuario E
20. r sostener 255 libras 102kg para el 2 Deje por lo menos 21 53 3 cm de espacio libre para la 1 2 5 cm Cable profundidad de la puerta cuando esta abierta all derecha o 3 La dimensi n G profundidad O del corte est primordial para modelo instalar correctamente el horno de pared Si el adorno del armaz n del horno no topa contra el armario verifique QU 0 15 16 si la dimensi n G est en 104 cm conformidad con la dimensi n nar requerida e 29 2 cm Puerta Abierta vea la nota 2 Espaciador N Caja el ctrica Espaciador de de empalme Distancia sugerida desde el Madera de 2 derecha o suelo es 11 2 29 2 cm 5 cm de izquierda La distancia m nima requerida ancho si es es 4 2 11 4 cm necesario Figura 1 DIMENSIONES DEL APARATO mooo a J 68 c T gt 27 68 DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO MODELO EA AO AO 27 68 6cm Wall Oven 247 s 63 2 25 64 1 23 59 7 41 3 104 5 41 104 8 27 s 68 9 Min 30 76 2cm Wall Oven 284 72 4 29 73 7 23 59 7 41 g 104 5 41 104 8 30 s 76 5 Min Todas las dimensiones se dan en pulgadas cm P N 318201533 0904 Rev A English pages 1 6 Espa ol p ginas 7 12 Impreso en los Estados Unidos INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE PARED Notas importantes para el instalador 1 Lea todas las instrucciones contenidas
21. see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage Protection Circuit Recommended Appliance Rating Watts 208V Less than 4100W 4100W 6200W Protection Circuit Recommended Appliance Rating Watts 240V Less than 4800W 4800W 7200W 9600W and 8300W and Table A Observe all governing codes and local ordinances 1 A 3 wire or 4 wire single phase 120 240 or 120 208 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line red and black wires A time delay fuse or circuit breaker is recommended DO NOT fuse neutral white wire Only certain cooktop models may be installed over certain built in electric oven models Approved cooktops and built in ovens are listed by the MFG ID number see the insert sheet included in the literature package NOTE Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI NFPA No 70 latest edition or with Canadian CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ordinances WARNING An extension cord should not be used with this appliance Such use may result in a fire electrical shock or other personal injury If you need a longer power cord you can purchase a 10 3 m power cord kit 903056 9010 by calling the Service Center 2 These applianc
22. sto le podr ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricaci n de este artefacto Lea la garant a y la informaci n sobre el servicio en su Manual del Usuario para obtener el n mero de tel fono gratuito y la direcci n del servicio
23. upper element in the oven should become red Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance Refer to your Use and Care Guide for service phone numbers INSTRUCCIONES DE INSTALACI N PARA EL COMBINACI N MICRO ONDAS HORNO DE PARED LA INSTALACI N Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO IMPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD LEA Y GUARDE ESTAS Re INSTRUCCIONES PARA REFERENCIA FUTURA PARA SU SEGURIDAD No almacen ni utilice gasolina u otros vapores y l quidos inflamables en la proximidad de este o de cualquier otro artefacto y compararlas con las que se indican en el cuadro de dimensiones del hueco de la figura 1 El primer paso para su instalaci n debe de ser el de medir las dimensiones de la apertura U Posiblemente encontrar que alg n trabajo de carpinter a ser necesario AA ADVERTENCIA No quite los separadores de los muros laterales o y de la parte posterior del horno empotrado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentraci n excesiva de calor que podr a resultar en da os por el calor o un incendio NOTAS Orificio 1 La base debe pode

Download Pdf Manuals

image

Related Search

Related Contents

  HQ W4-49902/4  啓発チラシ(PDF:170KB)  Istruzioni per l`uso  第一種特定製品の管理者・ 第一種フロン類充塡回収業  TEFAL GV7760CH Instruction Manual  TomTom RIDER  

Copyright © All rights reserved.